1
|
Gupta K. A robust deep learning system for screening of obstructive sleep apnea using T-F spectrum of ECG signals. Comput Methods Biomech Biomed Engin 2024:1-13. [PMID: 38829354 DOI: 10.1080/10255842.2024.2359635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 05/20/2024] [Indexed: 06/05/2024]
Abstract
Obstructive sleep apnea (OSA) is a non-communicable sleep-related medical condition marked by repeated disruptions in breathing during sleep. It may induce various cardiovascular and neurocognitive complications. Electrocardiography (ECG) is a useful method for detecting numerous health-related disorders. ECG signals provide a less complex and non-invasive solution for the screening of OSA. Automated and accurate detection of OSA may enhance diagnostic performance and reduce the clinician's workload. Traditional machine learning methods typically involve several labor-intensive manual procedures, including signal decomposition, feature evaluation, selection, and categorization. This article presents the time-frequency (T-F) spectrum classification of de-noised ECG data for the automatic screening of OSA patients using deep convolutional neural networks (DCNNs). At first, a filter-fusion algorithm is used to eliminate the artifacts from the raw ECG data. Stock-well transform (S-T) is employed to change filtered time-domain ECG into T-F spectrums. To discriminate between apnea and normal ECG signals, the obtained T-F spectrums are categorized using benchmark Alex-Net and Squeeze-Net, along with a less complex DCNN. The superiority of the presented system is measured by computing the sensitivity, specificity, accuracy, negative predicted value, precision, F1-score, and Fowlkes-Mallows index. The results of comparing all three utilized DCNNs reveal that the proposed DCNN requires fewer learning parameters and provides higher accuracy. An average accuracy of 95.31% is yielded using the proposed system. The presented deep learning system is lightweight and faster than Alex-Net and Squeeze-Net as it utilizes fewer learnable parameters, making it simple and reliable.
Collapse
Affiliation(s)
- Kapil Gupta
- School of Computer Sciences, University of Petroleum and Energy Studies (UPES), Dehradun, India
| |
Collapse
|
2
|
Liu K, Geng S, Shen P, Zhao L, Zhou P, Liu W. Development and application of a machine learning-based predictive model for obstructive sleep apnea screening. Front Big Data 2024; 7:1353469. [PMID: 38817683 PMCID: PMC11137315 DOI: 10.3389/fdata.2024.1353469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 04/29/2024] [Indexed: 06/01/2024] Open
Abstract
Objective To develop a robust machine learning prediction model for the automatic screening and diagnosis of obstructive sleep apnea (OSA) using five advanced algorithms, namely Extreme Gradient Boosting (XGBoost), Logistic Regression (LR), Support Vector Machine (SVM), Light Gradient Boosting Machine (LightGBM), and Random Forest (RF) to provide substantial support for early clinical diagnosis and intervention. Methods We conducted a retrospective analysis of clinical data from 439 patients who underwent polysomnography at the Affiliated Hospital of Xuzhou Medical University between October 2019 and October 2022. Predictor variables such as demographic information [age, sex, height, weight, body mass index (BMI)], medical history, and Epworth Sleepiness Scale (ESS) were used. Univariate analysis was used to identify variables with significant differences, and the dataset was then divided into training and validation sets in a 4:1 ratio. The training set was established to predict OSA severity grading. The validation set was used to assess model performance using the area under the curve (AUC). Additionally, a separate analysis was conducted, categorizing the normal population as one group and patients with moderate-to-severe OSA as another. The same univariate analysis was applied, and the dataset was divided into training and validation sets in a 4:1 ratio. The training set was used to build a prediction model for screening moderate-to-severe OSA, while the validation set was used to verify the model's performance. Results Among the four groups, the LightGBM model outperformed others, with the top five feature importance rankings of ESS total score, BMI, sex, hypertension, and gastroesophageal reflux (GERD), where Age, ESS total score and BMI played the most significant roles. In the dichotomous model, RF is the best performer of the five models respectively. The top five ranked feature importance of the best-performing RF models were ESS total score, BMI, GERD, age and Dry mouth, with ESS total score and BMI being particularly pivotal. Conclusion Machine learning-based prediction models for OSA disease grading and screening prove instrumental in the early identification of patients with moderate-to-severe OSA, revealing pertinent risk factors and facilitating timely interventions to counter pathological changes induced by OSA. Notably, ESS total score and BMI emerge as the most critical features for predicting OSA, emphasizing their significance in clinical assessments. The dataset will be publicly available on my Github.
Collapse
Affiliation(s)
- Kang Liu
- Department of Otolaryngology, Head and Neck Surgery, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Shi Geng
- Artificial Intelligence Unit, Department of Medical Equipment Management, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Ping Shen
- Department of Otolaryngology, Head and Neck Surgery, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Lei Zhao
- Artificial Intelligence Unit, Department of Medical Equipment Management, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Peng Zhou
- Department of Otolaryngology, Head and Neck Surgery, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Wen Liu
- Department of Otolaryngology, Head and Neck Surgery, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| |
Collapse
|
3
|
Fan X, Chen X, Ma W, Gao W. BAFNet: Bottleneck Attention Based Fusion Network for Sleep Apnea Detection. IEEE J Biomed Health Inform 2024; 28:2473-2484. [PMID: 37216250 DOI: 10.1109/jbhi.2023.3278657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Sleep apnea (SA) is a common sleep-related breathing disorder that tends to induce a series of complications, such as pediatric intracranial hypertension, psoriasis, and even sudden death. Therefore, early diagnosis and treatment can effectively prevent malignant complications SA incurs. Portable monitoring (PM) is a widely used tool for people to monitor their sleep conditions outside of hospitals. In this study, we focus on SA detection based on single-lead electrocardiogram (ECG) signals which are easily collected by PM. We propose a bottleneck attention based fusion network named BAFNet, which mainly includes five parts of RRI (R-R intervals) stream network, RPA (R-peak amplitudes) stream network, global query generation, feature fusion, and classifier. To learn the feature representation of RRI/RPA segments, fully convolutional networks (FCN) with cross-learning are proposed. Meanwhile, to control the information flow between RRI and RPA networks, a global query generation with bottleneck attention is proposed. To further improve the SA detection performance, a hard sample scheme with k-means clustering is employed. Experiment results show that BAFNet can achieve competitive results, which are superior to the state-of-the-art SA detection methods. It means that BAFNet has great potential to be applied in the home sleep apnea test (HSAT) for sleep condition monitoring.
Collapse
|
4
|
Safdar MF, Nowak RM, Pałka P. Pre-Processing techniques and artificial intelligence algorithms for electrocardiogram (ECG) signals analysis: A comprehensive review. Comput Biol Med 2024; 170:107908. [PMID: 38217973 DOI: 10.1016/j.compbiomed.2023.107908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/19/2023] [Accepted: 12/24/2023] [Indexed: 01/15/2024]
Abstract
Electrocardiogram (ECG) are the physiological signals and a standard test to measure the heart's electrical activity that depicts the movement of cardiac muscles. A review study has been conducted on ECG signals analysis with the help of artificial intelligence (AI) methods over the last ten years i.e., 2012-22. Primarily, the method of ECG analysis by software systems was divided into classical signal processing (e.g. spectrograms or filters), machine learning (ML) and deep learning (DL), including recursive models, transformers and hybrid. Secondly, the data sources and benchmark datasets were depicted. Authors grouped resources by ECG acquisition methods into hospital-based portable machines and wearable devices. Authors also included new trends like advanced pre-processing, data augmentation, simulations and agent-based modeling. The study found improvement in ECG examination perfection made each year through ML, DL, hybrid models, and transformers. Convolutional neural networks and hybrid models were more targeted and proved efficient. The transformer model extended the accuracy from 90% to 98%. The Physio-Net library helps acquire ECG signals, including the popular benchmark databases such as MIT-BIH, PTB, and challenging datasets. Similarly, wearable devices have been established as a appropriate option for monitoring patient health without the time and place limitations and are also helpful for AI model calibration with so far accuracy of 82%-83% on Samsung smartwatch. In the pre-processing signals, spectrogram generation through Fourier and wavelet transformations are erected leading approaches promoting on average accuracy of 90%-95%. Likewise, data enhancement using geometrical techniques is well-considered; however, extraction and concatenation-based methods need attention. As the what-if analysis in healthcare or cardiac issues can be performed using a complex simulation, the study reviews agent-based modeling and simulation approaches for cardiovascular risk event assessment.
Collapse
Affiliation(s)
- Muhammad Farhan Safdar
- Institute of Computer Science, Faculty of Electronics and Information Technology, Warsaw University of Technology, 00-665 Warsaw, Poland.
| | - Robert Marek Nowak
- Institute of Computer Science, Faculty of Electronics and Information Technology, Warsaw University of Technology, 00-665 Warsaw, Poland
| | - Piotr Pałka
- Institute of Control and Computation Engineering, Faculty of Electronics and Information Technology, Warsaw University of Technology, 00-665 Warsaw, Poland
| |
Collapse
|
5
|
Zhou Y, Kang K. Multi-Feature Automatic Extraction for Detecting Obstructive Sleep Apnea Based on Single-Lead Electrocardiography Signals. SENSORS (BASEL, SWITZERLAND) 2024; 24:1159. [PMID: 38400317 PMCID: PMC10892817 DOI: 10.3390/s24041159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/06/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024]
Abstract
Obstructive sleep apnea (OSA), a prevalent sleep disorder, is intimately associated with various other diseases, particularly cardiovascular conditions. The conventional diagnostic method, nocturnal polysomnography (PSG), despite its widespread use, faces challenges due to its high cost and prolonged duration. Recent developments in electrocardiogram-based diagnostic techniques have opened new avenues for addressing these challenges, although they often require a deep understanding of feature engineering. In this study, we introduce an innovative method for OSA classification that combines a composite deep convolutional neural network model with a multimodal strategy for automatic feature extraction. This approach involves transforming the original dataset into scalogram images that reflect heart rate variability attributes and Gramian angular field matrix images that reveal temporal characteristics, aiming to enhance the diversity and richness of data features. The model comprises automatic feature extraction and feature enhancement components and has been trained and validated on the PhysioNet Apnea-ECG database. The experimental results demonstrate the model's exceptional performance in diagnosing OSA, achieving an accuracy of 96.37%, a sensitivity of 94.67%, a specificity of 97.44%, and an AUC of 0.96. These outcomes underscore the potential of our proposed model as an efficient, accurate, and convenient tool for OSA diagnosis.
Collapse
Affiliation(s)
- Yu Zhou
- Department of Computer Science and Engineering, Major in Bio Artificial Intelligence, Hanyang University, Ansan 15588, Republic of Korea;
| | - Kyungtae Kang
- Department of Artificial Intelligence, Hanyang University, Ansan 15588, Republic of Korea
| |
Collapse
|
6
|
Li P, Ma W, Yue H, Lei W, Fan X, Li Y. Sleep apnea detection from single-lead electrocardiogram signals using effective deep-shallow fusion network. Physiol Meas 2024; 45:025002. [PMID: 38237197 DOI: 10.1088/1361-6579/ad205a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 01/18/2024] [Indexed: 02/10/2024]
Abstract
Objective.Explore a network architecture that can efficiently perform single-lead electrocardiogram (ECG) sleep apnea (SA) detection by utilizing the beneficial information of extended ECG segments and reducing the impact of their noisy information.Approach.We propose an effective deep-shallow fusion network (EDSFnet). The deeper residual network is used to extract high-level features with stronger semantics and less noise from the original ECG segments. The shallower convolutional neural network is used to extract lower-level features with higher resolution containing more detailed neighborhood information from the extended ECG segments. These two types of features are then fused using Effective Channel Attention, implementing automatic weight assignment to take advantage of their complementary nature.Main results.The performance of EDSFnet is evaluated on the Apnea-ECG dataset and the FAH-ECG dataset. In the Apnea-ECG dataset with 35 subjects as the training set and 35 subjects as the test set, the accuracy of EDSFnet was 92.6% and 100% for per-segment and per-recording test, respectively. In the FAH-ECG dataset with 348 subjects as the training set and 88 subjects as the test set, the accuracy of EDSFnet was 89.0% and 93.2% for per-segment and per-recording test, respectively. EDSFnet has achieved state-of-the-art results in both experiments using the publicly available Apnea-ECG dataset and subject-independent experiments using the FAH-ECG clinical dataset.Significance.The success of EDSFnet in handling SA detection underlines its robustness and adaptability. By achieving superior results across different datasets, EDSFnet offers promise in advancing the cost-effective and efficient detection of SA through single-lead ECG, reducing the burden on patients and healthcare systems alike.
Collapse
Affiliation(s)
- Pan Li
- School of Computer Science, South China Normal University, Guangzhou, People's Republic of China
| | - Wenjun Ma
- School of Computer Science, South China Normal University, Guangzhou, People's Republic of China
- Aberdeen Institute of Data Science and Artificial Intelligence, South China Normal University, Guangzhou, People's Republic of China
| | - Huijun Yue
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Wenbin Lei
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Xiaomao Fan
- Colledge of Big Data and Internet, Shenzhen Technology University, Shenzhen, People's Republic of China
| | - Ye Li
- Institue of Advanced Computing and Digital Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences Shenzhen, Shenzhen, People's Republic of China
| |
Collapse
|
7
|
Hu S, Wang Y, Liu J, Yang C, Wang A, Li K, Liu W. Semi-Supervised Learning for Low-Cost Personalized Obstructive Sleep Apnea Detection Using Unsupervised Deep Learning and Single-Lead Electrocardiogram. IEEE J Biomed Health Inform 2023; 27:5281-5292. [PMID: 37566509 DOI: 10.1109/jbhi.2023.3304299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/13/2023]
Abstract
OBJECTIVE Obstructive sleep apnea (OSA) is a common sleep-related breathing disorder that can lead to a wide range of health issues if left untreated. This study aims to address the lack of research on personalized models for single-lead electrocardiogram (ECG)-based OSA detection, by proposing an automatic semi-supervised algorithm for automated low-cost personalization fine-tuning. METHODS We utilize a convolutional neural network (CNN)-based auto-encoder (AE) with a modified training objective to detect anomalous region of OSA. An indicator based on model outputs is utilized as a benchmark measure to assign pseudo-labels with confidence to each sample. Finally, we perform validation of the semi-supervised algorithm on the same database and cross-database scenarios. RESULTS By introducing semi-supervised personalization, the accuracy, AUC, and mean absolute error (MAE) of the general model (GM) of 35 subjects from the same database are improved from 86.3%, 0.915, and 5.178 to 90.3%, 0.948, and 2.593. Simultaneously, in the validation of 25 subjects from a cross-database, the accuracy, AUC, and MAE of the GM are enhanced from 75.6%, 0.800, and 9.149 to 84.3%, 0.881, and 3.509. CONCLUSION The improved version of AE demonstrates excellent adaptability in identifying abnormal features in OSA, employing a data-driven approach to assign pseudo-labels for unknown data automatically. Additionally, leveraging the pseudo-labels through a semi-supervised fine-tuning strategy provides a solution to overcome the limitation of clinical annotations, facilitating low-cost implementation of personalized models. SIGNIFICANCE The semi-supervised approach proposed in this article provides a high-performance and annotation-free solution for personalized adjustment of automatic OSA detection.
Collapse
|
8
|
J RG, K D. Apnoea detection using ECG signal based on machine learning classifiers and its performances. J Med Eng Technol 2023; 47:344-354. [PMID: 38625408 DOI: 10.1080/03091902.2024.2336500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 03/23/2024] [Indexed: 04/17/2024]
Abstract
Sleep apnoea is a common disorder affecting sleep quality by obstructing the respiratory airway. This disorder can also be correlated to certain diseases like stroke, depression, neurocognitive disorder, non-communicable disease, etc. We implemented machine learning techniques for detecting sleep apnoea to make the diagnosis easier, feasible, convenient, and cost-effective. Electrocardiography signals are the main input used here to detect sleep apnoea. The considered ECG signal undergoes pre-processing to remove noise and other artefacts. Next to pre-processing, extraction of time and frequency domain features is carried out after finding out the R-R intervals from the pre-processed signal. The power spectral density is calculated by using the Welch method for extracting the frequency-domain features. The extracted features are fed to different machine learning classifiers like Support Vector Machine, Decision Tree, k-nearest Neighbour, and Random Forest, for detecting sleep apnoea and performances are analysed. The result shows that the K-NN classifier obtains the highest accuracy of 92.85% compared to other classifiers based on 10 extracted features. The result shows that the proposed method of signal processing and machine learning techniques can be reliable and a promising method for detecting sleep apnoea with a reduced number of features.
Collapse
Affiliation(s)
- Rolant Gini J
- Department of Electronics and Communication Engineering, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, India
| | - Dhanalakshmi K
- Department of Electronics and Communication Engineering, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, India
| |
Collapse
|
9
|
Arslan RS. Sleep disorder and apnea events detection framework with high performance using two-tier learning model design. PeerJ Comput Sci 2023; 9:e1554. [PMID: 37810361 PMCID: PMC10557519 DOI: 10.7717/peerj-cs.1554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 08/04/2023] [Indexed: 10/10/2023]
Abstract
Sleep apnea is defined as a breathing disorder that affects sleep. Early detection of sleep apnea helps doctors to take intervention for patients to prevent sleep apnea. Manually making this determination is a time-consuming and subjectivity problem. Therefore, many different methods based on polysomnography (PSG) have been proposed and applied to detect this disorder. In this study, a unique two-layer method is proposed, in which there are four different deep learning models in the deep neural network (DNN), gated recurrent unit (GRU), recurrent neural network (RNN), RNN-based-long term short term memory (LSTM) architecture in the first layer, and a machine learning-based meta-learner (decision-layer) in the second layer. The strategy of making a preliminary decision in the first layer and verifying/correcting the results in the second layer is adopted. In the training of this architecture, a vector consisting of 23 features consisting of snore, oxygen saturation, arousal and sleep score data is used together with PSG data. A dataset consisting of 50 patients, both children and adults, is prepared. A number of pre-processing and under-sampling applications have been made to eliminate the problem of unbalanced classes. Proposed method has an accuracy of 95.74% and 99.4% in accuracy of apnea detection (apnea, hypopnea and normal) and apnea types detection (central, mixed and obstructive), respectively. Experimental results demonstrate that patient-independent consistent results can be produced with high accuracy. This robust model can be considered as a system that will help in the decisions of sleep clinics where it is expected to detect sleep disorders in detail with high performance.
Collapse
|
10
|
Tyagi PK, Agarwal D. Systematic review of automated sleep apnea detection based on physiological signal data using deep learning algorithm: a meta-analysis approach. Biomed Eng Lett 2023; 13:293-312. [PMID: 37519869 PMCID: PMC10382448 DOI: 10.1007/s13534-023-00297-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 06/10/2023] [Accepted: 06/18/2023] [Indexed: 08/01/2023] Open
Abstract
Sleep apnea (SLA) is a respiratory-related sleep disorder that affects a major proportion of the population. The gold standard in sleep testing, polysomnography, is costly, inconvenient, and unpleasant, and it requires a skilled professional to score. Multiple researchers have suggested and developed automated scoring processes with less detectors and automated classification algorithms to resolve these problems. An automatic detection system will allow for a high diagnosis rate and the analysis of additional patients. Deep learning (DL) is achieving high priority due to the availability of databases and recently developed methods. As the most up-and-coming technique for classification and generative tasks, DL has shown its significant potential in 2-dimensional clinical image processing studies. However, physiological information collected as 1-dimensional data has yet to be effectively extracted from this new approach to achieve the needed medical goals. So, in this study, we review the most recent studies in the field of DL applied to physiological data based on pulse oxygen saturation, electrocardiogram, airflow, and sound signal. A total of 47 articles from different journals and publishing houses that were published between 2012 and 2022 were identified. The primary objective of this work is to perform a comprehensive analysis to analyze, classify, and compare the main characteristics of deep-learning algorithms applied in physiological data processing for SLA detection. Overall, our analysis provides comprehensive and detailed information for researchers looking to add to this field. The data input source, objective, DL network, training framework, and database references are the critical factors of the DL approach examined. These are the most critical variables that influence system performance. We categorized the relevant research studies in physiological sensor data analysis using the DL approach based on (1) Physiological sensor data aspects, like signal types, sampling frequency, and window size; and (2) DL model perspectives, such as learning structure and input data types. Supplementary Information The online version contains supplementary material available at 10.1007/s13534-023-00297-5.
Collapse
Affiliation(s)
- Praveen Kumar Tyagi
- Department of ECE, Maulana Azad National Institute of Technology, Bhopal, 462003 India
| | - Dheeraj Agarwal
- Department of ECE, Maulana Azad National Institute of Technology, Bhopal, 462003 India
| |
Collapse
|
11
|
Bazoukis G, Bollepalli SC, Chung CT, Li X, Tse G, Bartley BL, Batool-Anwar S, Quan SF, Armoundas AA. Application of artificial intelligence in the diagnosis of sleep apnea. J Clin Sleep Med 2023; 19:1337-1363. [PMID: 36856067 PMCID: PMC10315608 DOI: 10.5664/jcsm.10532] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 02/21/2023] [Accepted: 02/21/2023] [Indexed: 03/02/2023]
Abstract
STUDY OBJECTIVES Machine learning (ML) models have been employed in the setting of sleep disorders. This review aims to summarize the existing data about the role of ML techniques in the diagnosis, classification, and treatment of sleep-related breathing disorders. METHODS A systematic search in Medline, EMBASE, and Cochrane databases through January 2022 was performed. RESULTS Our search strategy revealed 132 studies that were included in the systematic review. Existing data show that ML models have been successfully used for diagnostic purposes. Specifically, ML models showed good performance in diagnosing sleep apnea using easily obtained features from the electrocardiogram, pulse oximetry, and sound signals. Similarly, ML showed good performance for the classification of sleep apnea into obstructive and central categories, as well as predicting apnea severity. Existing data show promising results for the ML-based guided treatment of sleep apnea. Specifically, the prediction of outcomes following surgical treatment and optimization of continuous positive airway pressure therapy can be guided by ML models. CONCLUSIONS The adoption and implementation of ML in the field of sleep-related breathing disorders is promising. Advancements in wearable sensor technology and ML models can help clinicians predict, diagnose, and classify sleep apnea more accurately and efficiently. CITATION Bazoukis G, Bollepalli SC, Chung CT, et al. Application of artificial intelligence in the diagnosis of sleep apnea. J Clin Sleep Med. 2023;19(7):1337-1363.
Collapse
Affiliation(s)
- George Bazoukis
- Department of Cardiology, Larnaca General Hospital, Larnaca, Cyprus
- Department of Basic and Clinical Sciences, University of Nicosia Medical School, Nicosia, Cyprus
| | | | - Cheuk To Chung
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, China-UK Collaboration, Hong Kong
| | - Xinmu Li
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular disease, Department of Cardiology, Tianjin Institute of Cardiology, the Second Hospital of Tianjin Medical University, Tianjin, China
| | - Gary Tse
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, China-UK Collaboration, Hong Kong
- Kent and Medway Medical School, Canterbury, Kent, United Kingdom
| | - Bethany L. Bartley
- Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital, Boston, Massachusetts
| | - Salma Batool-Anwar
- Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital, Boston, Massachusetts
| | - Stuart F. Quan
- Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital, Boston, Massachusetts
- Asthma and Airway Disease Research Center, University of Arizona College of Medicine, Tucson, Arizona
| | - Antonis A. Armoundas
- Cardiovascular Research Center, Massachusetts General Hospital, Boston, Massachusetts
- Broad Institute, Massachusetts Institute of Technology, Cambridge, Massachusetts
| |
Collapse
|
12
|
Martín-González S, Ravelo-García AG, Navarro-Mesa JL, Hernández-Pérez E. Combining Heart Rate Variability and Oximetry to Improve Apneic Event Screening in Non-Desaturating Patients. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094267. [PMID: 37177472 PMCID: PMC10181515 DOI: 10.3390/s23094267] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 04/17/2023] [Accepted: 04/18/2023] [Indexed: 05/15/2023]
Abstract
In this paper, we thoroughly analyze the detection of sleep apnea events in the context of Obstructive Sleep Apnea (OSA), which is considered a public health problem because of its high prevalence and serious health implications. We especially evaluate patients who do not always show desaturations during apneic episodes (non-desaturating patients). For this purpose, we use a database (HuGCDN2014-OXI) that includes desaturating and non-desaturating patients, and we use the widely used Physionet Apnea Dataset for a meaningful comparison with prior work. Our system combines features extracted from the Heart-Rate Variability (HRV) and SpO2, and it explores their potential to characterize desaturating and non-desaturating events. The HRV-based features include spectral, cepstral, and nonlinear information (Detrended Fluctuation Analysis (DFA) and Recurrence Quantification Analysis (RQA)). SpO2-based features include temporal (variance) and spectral information. The features feed a Linear Discriminant Analysis (LDA) classifier. The goal is to evaluate the effect of using these features either individually or in combination, especially in non-desaturating patients. The main results for the detection of apneic events are: (a) Physionet success rate of 96.19%, sensitivity of 95.74% and specificity of 95.25% (Area Under Curve (AUC): 0.99); (b) HuGCDN2014-OXI of 87.32%, 83.81% and 88.55% (AUC: 0.934), respectively. The best results for the global diagnosis of OSA patients (HuGCDN2014-OXI) are: success rate of 95.74%, sensitivity of 100%, and specificity of 89.47%. We conclude that combining both features is the most accurate option, especially when there are non-desaturating patterns among the recordings under study.
Collapse
Affiliation(s)
- Sofía Martín-González
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - Antonio G Ravelo-García
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
- Interactive Technologies Institute (ITI/LARSyS and ARDITI), 9020-105 Funchal, Portugal
| | - Juan L Navarro-Mesa
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - Eduardo Hernández-Pérez
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| |
Collapse
|
13
|
Detection of obstructive sleep apnea from single-channel ECG signals using a CNN-transformer architecture. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
14
|
Chen Y, Yue H, Zou R, Lei W, Ma W, Fan X. RAFNet: Restricted attention fusion network for sleep apnea detection. Neural Netw 2023; 162:571-580. [PMID: 37003136 DOI: 10.1016/j.neunet.2023.03.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 02/02/2023] [Accepted: 03/14/2023] [Indexed: 04/03/2023]
Abstract
Sleep apnea (SA) is a common sleep-related breathing disorder, which would lead to damage of multiple systemic organs or even sudden death. In clinical practice, portable device is an important tool to monitor sleep conditions and detect SA events by using physiological signals. However, SA detection performance is still limited due to physiological signals with time-variability and complexity. In this paper, we focus on SA detection with single lead ECG signals, which can be easily collected by a portable device. Under this context, we propose a restricted attention fusion network called RAFNet for sleep apnea detection. Specifically, RR intervals (RRI) and R-peak amplitudes (Rpeak) are generated from ECG signals and divided into one-minute-long segments. To alleviate the problem of insufficient feature information of the target segment, we combine the target segment with two pre- and post-adjacent segments in sequence, (i.e. a five-minute-long segment), as the input. Meanwhile, by leveraging the target segment as the query vector, we propose a new restricted attention mechanism with cascaded morphological and temporal attentions, which can effectively learn the feature information and depress redundant feature information from the adjacent segments with adaptive assigning weight importance. To further improve the SA detection performance, the target and adjacent segment features are fused together with the channel-wise stacking scheme. Experiment results on the public Apnea-ECG dataset and the real clinical FAH-ECG dataset with sleep apnea annotations show that the RAFNet greatly improves SA detection performance and achieves competitive results, which are superior to those achieved by the state-of-the-art baselines.
Collapse
Affiliation(s)
- Ying Chen
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Huijun Yue
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ruifeng Zou
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Wenbin Lei
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Wenjun Ma
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Xiaomao Fan
- College of Big Data and Internet, Shenzhen Technology University, Shenzhen, China.
| |
Collapse
|
15
|
Kumar Tyagi P, Agrawal D. Automatic detection of sleep apnea from single-lead ECG signal using enhanced-deep belief network model. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.104401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
16
|
Indrawati AN, Nuryani N, Nugroho AS, Utomo TP. Obstructive Sleep Apnea Detection using Frequency Analysis of Electrocardiographic RR Interval and Machine Learning Algorithms. J Biomed Phys Eng 2022; 12:627-636. [PMID: 36569571 PMCID: PMC9759644 DOI: 10.31661/jbpe.v0i0.2010-1216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 02/03/2021] [Indexed: 06/17/2023]
Abstract
BACKGROUND Obstructive Sleep Apnea (OSA) is a respiratory disorder due to obstructive upper airway (mainly in the oropharynx) periodically during sleep. The common examination used to diagnose sleep disorders is Polysomnography (PSG). Diagnose with PSG feels uncomfortable for the patient because the patient's body is fitted with many sensors. OBJECTIVE This study aims to propose an OSA detection using the Fast Fourier Transform (FFT) statistics of electrocardiographic RR Interval (R interval from one peak to the peak of the pulse of the next pulse R) and machine learning algorithms. MATERIAL AND METHODS In this case-control study, data were taken from the Massachusetts Institute of Technology at Beth Israel Hospital (MIT-BIH) based on the Apnea ECG database (RR Interval). The machine learning algorithms were Linear Discriminant Analysis (LDA), Artificial Neural Network (ANN), K-Nearest Neighbors (K-NN), and Support Vector Machine (SVM). RESULTS The OSA detection technique was designed and tested, and five features of the FFT were examined, namely mean (f1), Shannon entropy (f2), standard deviation (f3), median (f4), and geometric mean (f5). The OSA detection found the highest performance using ANN. Among the ANN types tested, the ANN with gradient descent backpropagation resulted in the best performance with accuracy, sensitivity, and specificity of 84.64%, 94.21%, and 64.03%, respectively. The lowest performance was found when LDA was applied. CONCLUSION ANN with gradient-descent backpropagation performed higher than LDA, SVM, and KNN for OSA detection.
Collapse
Affiliation(s)
- Aida Noor Indrawati
- MSc, Medical Instrumentation, Physics, University Sebelas Maret, Jl. Ir. Sutami 36A Kentingan Jebres Surakarta 57126, Indonesia
| | - Nuryani Nuryani
- PhD, Medical Instrumentation, Physics, University of Sebelas Maret. Jl. Ir. Sutami 36A Kentingan Jebres Surakarta 57126, Indonesia
| | - Anto Satriyo Nugroho
- PhD, Center for Information and Communication Technology Agency for Assessment and Application of Technology, Indonesia
| | - Trio Pambudi Utomo
- MSc, Medical Instrumentation, Physics, University Sebelas Maret, Jl. Ir. Sutami 36A Kentingan Jebres Surakarta 57126, Indonesia
| |
Collapse
|
17
|
Setiawan F, Lin CW. A Deep Learning Framework for Automatic Sleep Apnea Classification Based on Empirical Mode Decomposition Derived from Single-Lead Electrocardiogram. Life (Basel) 2022; 12:1509. [PMID: 36294943 PMCID: PMC9605343 DOI: 10.3390/life12101509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/30/2022] [Accepted: 09/14/2022] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Although polysomnography (PSG) is a gold standard tool for diagnosing sleep apnea (SA), it can reduce the patient's sleep quality by the placement of several disturbing sensors and can only be interpreted by a highly trained sleep technician or scientist. In recent years, electrocardiogram (ECG)-derived respiration (EDR) and heart rate variability (HRV) have been used to automatically diagnose SA and reduce the drawbacks of PSG. Up to now, most of the proposed approaches focus on machine-learning (ML) algorithms and feature engineering, which require prior expert knowledge and experience. The present study proposes an SA detection algorithm to differentiate a normal and apnea event using a deep-learning (DL) framework based on 1D and 2D deep CNN with empirical mode decomposition (EMD) of a preprocessed ECG signal. The EMD is ideally suited to extract essential components which are characteristic of the underlying biological or physiological processes. In addition, the simple and compact architecture of 1D deep CNN, which only performs 1D convolutions, and pretrained 2D deep CNNs, are suitable for real-time and low-cost hardware implementation. METHOD This study was validated using 7 h to nearly 10 h overnight ECG recordings from 33 subjects with an average apnea-hypopnea index (AHI) of 30.23/h originated from PhysioNet Apnea-ECG database (PAED). In preprocessing, the raw ECG signal was normalized and filtered using the FIR band pass filter. The preprocessed ECG signal was then decomposed using the empirical mode decomposition (EMD) technique to generate several features. Several important generated features were selected using neighborhood component analysis (NCA). Finally, deep learning algorithm based on 1D and 2D deep CNN were used to perform the classification of normal and apnea event. The synthetic minority oversampling technique (SMOTE) was also applied to evaluate the influence of the imbalanced data problem. RESULTS The segment-level classification performance had 93.8% accuracy with 94.9% sensitivity and 92.7% specificity based on 5-fold cross-validation (5fold-CV), meanwhile, the subject-level classification performance had 83.5% accuracy with 75.9% sensitivity and 88.7% specificity based on leave-one-subject-out cross-validation (LOSO-CV). CONCLUSION A novel and robust SA detection algorithm based on the ECG decomposed signal using EMD and deep CNN was successfully developed in this study.
Collapse
Affiliation(s)
- Febryan Setiawan
- Department of Biomedical Engineering, College of Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - Che-Wei Lin
- Department of Biomedical Engineering, College of Engineering, National Cheng Kung University, Tainan 701, Taiwan
- Institute of Gerontology, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
- Institute of Medical Informatics, College of Electrical Engineering and Computer Science, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
18
|
Chen J, Shen M, Ma W, Zheng W. A spatio-temporal learning-based model for sleep apnea detection using single-lead ECG signals. Front Neurosci 2022; 16:972581. [PMID: 35992920 PMCID: PMC9389170 DOI: 10.3389/fnins.2022.972581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Accepted: 07/18/2022] [Indexed: 11/13/2022] Open
Abstract
Sleep apnea (SA) is a common chronic sleep breathing disorder, which would cause stroke, cognitive decline, cardiovascular disease, or even death. The SA symptoms often manifest as frequent breathing interruptions during sleep and most individuals with sleeping disorders are not aware of the SA events. Using a portable device with single-lead ECG signal is an effective way to help an individual to monitor their sleep conditions at home. However, the SA detection performance of ECG-based methods is still difficult to meet the clinical practice requirement. In this study, we propose an end-to-end spatio-temporal learning-based SA detection method, which consists of multiple spatio-temporal blocks. Each block has the identical architecture with a convolutional neural network (CNN) layer, a max-pooling layer, and a bi-gated recurrent unit (BiGRU) layer. This architecture with repeated spatio-temporal blocks can well capture the morphological spatial feature information as well as the temporal feature information from ECG signals. The proposed SA detection model was evaluated on the publicly available datasets of PhysioNet Apnea-ECG dataset (Apnea-ECG) and University College Dublin Sleep Apnea Database (UCDDB). Extensive experimental results show that our proposed SA model on both Apnea-ECG and UCDDB datasets achieves state-of-the-art results, which are obviously superior to existing ECG-based SA detection methods. It means that our proposed method has the potential to be deployed into a healthcare system to provide a sleep monitoring service, which can screen out SA population with high risk and help to take timely interventions to prevent serious consequences.
Collapse
Affiliation(s)
- Junyang Chen
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Mengqi Shen
- Grado Department of Industrial and Systems Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, United States
| | - Wenjun Ma
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Weiping Zheng
- School of Computer Science, South China Normal University, Guangzhou, China
- *Correspondence: Weiping Zheng
| |
Collapse
|
19
|
Wang T, Lu C, Sun Y, Fang H, Jiang W, Liu C. A method to detect sleep apnea using residual attention mechanism network from single-lead ECG signal. BIOMED ENG-BIOMED TE 2022; 67:357-365. [PMID: 35920638 DOI: 10.1515/bmt-2022-0067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 07/11/2022] [Indexed: 11/15/2022]
Abstract
Sleep apnea is a sleep disorder caused by weakened or suspended breathing during sleep, which seriously affects the work and health of patients. The traditional polysomnography (PSG) detection process is complicated and expensive, which has attracted researchers to explore a rapid detection method based on single-lead ECG signals. However, existing ECG-based sleep apnea detection methods have certain limitations and complexities, mainly relying on human-crafted features. To solve the problem, the paper develops a sleep apnea detection method based on a residual attention mechanism network. The method uses the RR interval signal and the R-peak signal derived from the ECG signal as input, realizes feature extraction through the residual network (ResNet), and adds the SENet attention mechanism to deepen the mining of channel features. Experimental results show that the per-segment accuracy of the proposed method can reach 86.2%. Compared with existing works, its accuracy has increased by 1.1-8.1%. These results show that the proposed residual attention network can effectively use ECG signals to quickly detect sleep apnea. Meanwhile, compared with existing works, the proposed method overcomes the limitations and complexity of human-crafted features in sleep apnea detection research.
Collapse
Affiliation(s)
- Tao Wang
- School of Computer and Information, Hefei University of Technology, Hefei, Anhui, China
| | - Changhua Lu
- School of Computer and Information, Hefei University of Technology, Hefei, Anhui, China
| | - Yining Sun
- Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui, China
| | - Hengyang Fang
- School of Computer and Information, Hefei University of Technology, Hefei, Anhui, China
| | - Weiwei Jiang
- Intelligent Interconnected Systems Laboratory of Anhui Province, Hefei University of Technology, Hefei, Anhui, China
| | - Chun Liu
- School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, Anhui, China
| |
Collapse
|
20
|
Chen X, Chen Y, Ma W, Fan X, Li Y. Toward sleep apnea detection with lightweight multi-scaled fusion network. Knowl Based Syst 2022. [DOI: 10.1016/j.knosys.2022.108783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
21
|
Ayatollahi A, Afrakhteh S, Soltani F, Saleh E. Sleep apnea detection from ECG signal using deep CNN-based structures. EVOLVING SYSTEMS 2022. [DOI: 10.1007/s12530-022-09445-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
22
|
Detection of Sleep Apnea from Electrocardiogram and Pulse Oximetry Signals Using Random Forest. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094218] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Sleep apnea (SA) is a common sleep disorder which could impair the human physiological system. Therefore, early diagnosis of SA is of great interest. The traditional method of diagnosing SA is an overnight polysomnography (PSG) evaluation. When PSG has limited availability, automatic SA screening with a fewer number of signals should be considered. The primary purpose of this study is to develop and evaluate a SA detection model based on electrocardiogram (ECG) and blood oxygen saturation (SpO2). We adopted a multimodal approach to fuse ECG and SpO2 signals at the feature level. Then, feature selection was conducted using the recursive feature elimination with cross-validation (RFECV) algorithm and random forest (RF) classifier used to discriminate between apnea and normal events. Experiments were conducted on the Apnea-ECG database. The introduced algorithm obtained an accuracy of 97.5%, a sensitivity of 95.9%, a specificity of 98.4% and an AUC of 0.992 in per-segment classification, and outperformed previous works. The results showed that ECG and SpO2 are complementary in detecting SA, and that the combination of ECG and SpO2 enhances the ability to diagnose SA. Therefore, the proposed method has the potential to be an alternative to conventional detection methods.
Collapse
|
23
|
Classification of Respiratory States Using Spectrogram with Convolutional Neural Network. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12041895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This paper proposes an approach to the classification of respiration states based on a neural network model by visualizing respiratory signals using a spectrogram. The analysis and processing of human biosignals are still considered some of the most crucial and fundamental research areas in both signal processing and medical applications. Recently, learning-based algorithms in signal and image processing for medical applications have shown significant improvement from both quantitative and qualitative perspectives. Human respiration is still considered an important factor for diagnosis, and it plays a key role in preventing fatal diseases in practice. This paper chiefly deals with a contactless-based approach for the acquisition of respiration data using an ultra-wideband (UWB) radar sensor because it is simple and easy for use in an experimental setup and shows high accuracy in distance estimation. This paper proposes the classification of respiratory states by using a feature visualization scheme, a spectrogram, and a neural network model. The proposed method shows competitive and promising results in the classification of respiratory states. The experimental results also show that the method provides better accuracy (precision: 0.86 and specificity: 0.90) than conventional methods that use expensive equipment for respiration measurement.
Collapse
|
24
|
Qin H, Liu G. A dual-model deep learning method for sleep apnea detection based on representation learning and temporal dependence. Neurocomputing 2022. [DOI: 10.1016/j.neucom.2021.12.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
25
|
Sleep Apnea Detection Based on Multi-Scale Residual Network. Life (Basel) 2022; 12:life12010119. [PMID: 35054512 PMCID: PMC8781811 DOI: 10.3390/life12010119] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 01/09/2022] [Accepted: 01/10/2022] [Indexed: 11/22/2022] Open
Abstract
Aiming at the fact that traditional convolutional neural networks cannot effectively extract signal features in complex application scenarios, a sleep apnea (SA) detection method based on multi-scale residual networks is proposed. First, we analyze the physiological mechanism of SA, which uses the RR interval signals and R peak signals derived from the ECG signals as input. Then, a multi-scale residual network is used to extract the characteristics of the original signals in order to obtain sensitive characteristics from various angles. Because the residual structure is used in the model, the problem of model degradation can be avoided. Finally, a fully connected layer is introduced for SA detection. In order to overcome the impact of class imbalance, a focal loss function is introduced to replace the traditional cross-entropy loss function, which makes the model pay more attention to learning difficult samples in the training phase. Experimental results from the Apnea-ECG dataset show that the accuracy, sensitivity and specificity of the proposed multi-scale residual network are 86.0%, 84.1% and 87.1%, respectively. These results indicate that the proposed method not only achieves greater recognition accuracy than other methods, but it also effectively resolves the problem of low sensitivity caused by class imbalance.
Collapse
|
26
|
Benkő Z, Bábel T, Somogyvári Z. Model-free detection of unique events in time series. Sci Rep 2022; 12:227. [PMID: 34996940 PMCID: PMC8742065 DOI: 10.1038/s41598-021-03526-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/29/2021] [Indexed: 11/10/2022] Open
Abstract
Recognition of anomalous events is a challenging but critical task in many scientific and industrial fields, especially when the properties of anomalies are unknown. In this paper, we introduce a new anomaly concept called “unicorn” or unique event and present a new, model-free, unsupervised detection algorithm to detect unicorns. The key component of the new algorithm is the Temporal Outlier Factor (TOF) to measure the uniqueness of events in continuous data sets from dynamic systems. The concept of unique events differs significantly from traditional outliers in many aspects: while repetitive outliers are no longer unique events, a unique event is not necessarily an outlier; it does not necessarily fall out from the distribution of normal activity. The performance of our algorithm was examined in recognizing unique events on different types of simulated data sets with anomalies and it was compared with the Local Outlier Factor (LOF) and discord discovery algorithms. TOF had superior performance compared to LOF and discord detection algorithms even in recognizing traditional outliers and it also detected unique events that those did not. The benefits of the unicorn concept and the new detection method were illustrated by example data sets from very different scientific fields. Our algorithm successfully retrieved unique events in those cases where they were already known such as the gravitational waves of a binary black hole merger on LIGO detector data and the signs of respiratory failure on ECG data series. Furthermore, unique events were found on the LIBOR data set of the last 30 years.
Collapse
Affiliation(s)
- Zsigmond Benkő
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, 1121, Hungary.,János Szentágothai Doctoral School of Neurosciences, Semmelweis University, Ullői road 26, Budapest, 1085, Hungary
| | - Tamás Bábel
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, 1121, Hungary
| | - Zoltán Somogyvári
- Department of Computational Sciences, Wigner Research Centre for Physics, Budapest, 1121, Hungary.
| |
Collapse
|
27
|
Yang Q, Zou L, Wei K, Liu G. Obstructive sleep apnea detection from single-lead electrocardiogram signals using one-dimensional squeeze-and-excitation residual group network. Comput Biol Med 2022; 140:105124. [PMID: 34896885 DOI: 10.1016/j.compbiomed.2021.105124] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 12/04/2021] [Accepted: 12/04/2021] [Indexed: 11/17/2022]
Abstract
Obstructive sleep apnea (OSA), which has high morbidity and complications, is diagnosed via polysomnography (PSG). However, this method is expensive, time-consuming, and causes discomfort to the patient. Single-lead electrocardiogram (ECG) is a potential alternative to PSG for OSA diagnosis. Recent studies have successfully applied deep learning methods to OSA detection using ECG and obtained great success. However, most of these methods only focus on heart rate variability (HRV), ignoring the importance of ECG-derived respiration (EDR). In addition, they used relatively simple networks, and cannot extract more complex features. In this study, we proposed a one-dimensional squeeze-and-excitation (SE) residual group network to thoroughly extract the complementary information between HRV and EDR. We used the released and withheld sets in the Apnea-ECG dataset to develop and test the proposed method, respectively. In the withheld set, the method has an accuracy of 90.3%, a sensitivity of 87.6%, and a specificity of 91.9% for per-segment detection, indicating an improvement over existing methods for the same dataset. The proposed method can be integrated with wearable devices to realize inexpensive, convenient, and highly efficient OSA detectors.
Collapse
Affiliation(s)
- Quanan Yang
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China
| | - Lang Zou
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China
| | - Keming Wei
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China
| | - Guanzheng Liu
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, 518107, China.
| |
Collapse
|
28
|
Detection of sleep apnea using deep neural networks and single-lead ECG signals. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103125] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
29
|
Weng P, Wei K, Chen T, Chen M, Liu G. Fuzzy Approximate Entropy of Extrema Based on Multiple Moving Averages as a Novel Approach in Obstructive Sleep Apnea Screening. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2022; 10:4901211. [PMID: 36247084 PMCID: PMC9564195 DOI: 10.1109/jtehm.2022.3197084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/17/2022] [Accepted: 07/25/2022] [Indexed: 11/29/2022]
Abstract
Objective: Obstructive sleep apnea (OSA) is a respiratory disease associated with autonomic nervous system dysfunction. As a novel method for analyzing OSA depending on heart rate variability, fuzzy approximate entropy of extrema based on multiple moving averages (Emma-fApEn) can effectively assess the sympathetic tension limits, thereby realizing a good performance in the disease severity screening. Method: Sixty 6-h electrocardiogram recordings (20 healthy, 16 mild/moderate OSA and 34 severe OSA) from the PhysioNet database were used in this study. The performances of minima of Emma-fApEn (fApEn-minima), maxima of Emma-fApEn (fApEn-maxima) and classic time-frequency domain indices for each recording were assessed by significance analysis, correlation analysis, parameter optimization and OSA screening. Results: fApEn-minima and fApEn-maxima had significant differences between the severe OSA group and the other two groups, while the mean value (Mean) and the ratio of low-frequency power and high-frequency power (LH) could significantly differentiate OSA recordings from healthy recordings. The correlation coefficient between fApEn-minima and apnea-hypopnea index was the highest (|R| = 0.705). Machine learning methods were used to evaluate the performances of the above four indices. Random forest (RF) achieved the highest accuracy of 96.67% in OSA screening and 91.67% in severe OSA screening, with a good balance in both. Conclusion: Emma-fApEn may be used as a simple preliminary detection tool to assess the severity of OSA prior to polysomnography analysis.
Collapse
Affiliation(s)
- Peiyu Weng
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Keming Wei
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Tian Chen
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Mingjing Chen
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Guanzheng Liu
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
30
|
Lee S, Chu Y, Ryu J, Park YJ, Yang S, Koh SB. Artificial Intelligence for Detection of Cardiovascular-Related Diseases from Wearable Devices: A Systematic Review and Meta-Analysis. Yonsei Med J 2022; 63:S93-S107. [PMID: 35040610 PMCID: PMC8790582 DOI: 10.3349/ymj.2022.63.s93] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 10/27/2021] [Accepted: 10/31/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE Several artificial intelligence (AI) models for the detection and prediction of cardiovascular-related diseases, including arrhythmias, diabetes, and sleep apnea, have been reported. This systematic review and meta-analysis aimed to identify AI models developed for or applicable to wearable and mobile devices for diverse cardiovascular-related diseases. MATERIALS AND METHODS The searched databases included Medline, Embase, and Cochrane Library. For AI models for atrial fibrillation (AF) detection, a meta-analysis of diagnostic accuracy was performed to summarize sensitivity and specificity. RESULTS A total of 102 studies were included in the qualitative review. There were AI models for the detection of arrythmia (n=62), followed by sleep apnea (n=11), peripheral vascular diseases (n=6), diabetes mellitus (n=5), hyper/hypotension (n=5), valvular heart disease (n=4), heart failure (n=3), myocardial infarction and cardiac arrest (n=2), and others (n=4). For quantitative analysis of 26 studies reporting AI models for AF detection, meta-analyzed sensitivity was 94.80% and specificity was 96.96%. Deep neural networks showed superior performance [meta-analyzed area under receiver operating characteristics curve (AUROC) of 0.981] compared to conventional machine learning algorithms (meta-analyzed AUROC of 0.961). However, AI models tested with proprietary dataset (meta-analyzed AUROC of 0.972) or data acquired from wearable devices (meta-analyzed AUROC of 0.977) showed inferior performance than those with public dataset (meta-analyzed AUROC of 0.986) or data from in-hospital devices (meta-analyzed AUROC of 0.983). CONCLUSION This review found that AI models for diverse cardiovascular-related diseases are being developed, and that they are gradually developing into a form that is suitable for wearable and mobile devices.
Collapse
Affiliation(s)
- Solam Lee
- Department of Preventive Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea
- Department of Dermatology, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Yuseong Chu
- Department of Biomedical Engineering, Yonsei University, Wonju, Korea
| | - Jiseung Ryu
- Department of Biomedical Engineering, Yonsei University, Wonju, Korea
| | - Young Jun Park
- Division of Cardiology, Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Sejung Yang
- Department of Biomedical Engineering, Yonsei University, Wonju, Korea.
| | - Sang Baek Koh
- Department of Preventive Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea.
| |
Collapse
|
31
|
Sadoughi A, Shamsollahi MB, Fatemizadeh E. Automatic detection of respiratory events during sleep from Polysomnography data using Layered Hidden Markov Model. Physiol Meas 2021; 43. [PMID: 34936995 DOI: 10.1088/1361-6579/ac45e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 12/22/2021] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Sleep apnea is a serious respiratory disorder, which is associated with increased risk factors for cardiovascular disease. Many studies in recent years have been focused on automatic detection of sleep apnea from polysomnography (PSG) recordings, however, detection of subtle respiratory events named Respiratory Event Related Arousals (RERAs) that do not meet the criteria for apnea or hypopnea is still challenging. The objective of this study was to develop automatic detection of sleep apnea based on Hidden Markov Models (HMMs) which are probabilistic models with the ability to learn different dynamics of the real time-series such as clinical recordings. APPROACH In this study, a hierarchy of HMMs named Layered HMM was presented to detect respiratory events from PSG recordings. The recordings of 210 PSGs from Massachusetts General Hospital's database were used for this study. To develop detection algorithms, extracted feature signals from airflow, movements over the chest and abdomen, and oxygen saturation in blood (SaO2) were chosen as observations. The respiratory disturbance index (RDI) was estimated as the number of apneas, hypopneas, and RERAs per hour of sleep. MAIN RESULTS The best F1 score of the event by event detection algorithm was between 0.22±0.16 and 0.70±0.08 for different groups of sleep apnea severity. There was a strong correlation between the estimated and the PSG-derived RDI (R2=0.91, p<0.0001). The best recall of RERA detection was achieved 0.45±0.27. SIGNIFICANCE The results showed that the layered structure can improve the performance of the detection of respiratory events during sleep.
Collapse
Affiliation(s)
- Azadeh Sadoughi
- Department of Biomedical Engineering, Islamic Azad University Science and Research Branch, Science and Research Branch,shodada Hesarak blvd, Daneshgah Square,Sattari Highway,Tehran, I.R. IRAN;, Tehran, Tehran, 1477893855 , Iran (the Islamic Republic of)
| | - Mohammad Bagher Shamsollahi
- Biomedical Signal and Image Processing Laboratory (BiSIPL), School of Electrical Engineering, Sharif University of Technology, Sharif University of Technology, Azadi Ave, Tehran, Iran, Tehran, Tehran, 1458889694, Iran (the Islamic Republic of)
| | - Emad Fatemizadeh
- Biomedical Signal and Image Processing Laboratory (BiSIPL), School of Electrical Engineering, Sharif University of Technology, Sharif University of Technology, Azadi Ave, Tehran, Iran, Tehran, Tehran, 1458889694, Iran (the Islamic Republic of)
| |
Collapse
|
32
|
Apnea Detection in Polysomnographic Recordings Using Machine Learning Techniques. Diagnostics (Basel) 2021; 11:diagnostics11122302. [PMID: 34943539 PMCID: PMC8700500 DOI: 10.3390/diagnostics11122302] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 11/15/2021] [Accepted: 11/17/2021] [Indexed: 11/20/2022] Open
Abstract
Sleep disorders are diagnosed in sleep laboratories by polysomnography, a multi-parameter examination that monitors biological signals during sleep. The subsequent evaluation of the obtained records is very time-consuming. The goal of this study was to create an automatic system for evaluation of the airflow and SpO2 channels of polysomnography records, through the use of machine learning techniques and a large database, for apnea and desaturation detection (which is unusual in other studies). To that end, a convolutional neural network (CNN) was designed using hyperparameter optimization. It was then trained and tested for apnea and desaturation. The proposed CNN was compared with the commonly used k-nearest neighbors (k-NN) method. The classifiers were designed based on nasal airflow and blood oxygen saturation signals. The final neural network accuracy for apnea detection reached 84%, and that for desaturation detection was 74%, while the k-NN classifier reached accuracies of 83% and 64% for apnea detection and desaturation detection, respectively.
Collapse
|
33
|
Afrakhteh S, Ayatollahi A, Soltani F. Classification of sleep apnea using EMD-based features and PSO-trained neural networks. BIOMED ENG-BIOMED TE 2021; 66:459-472. [PMID: 33930264 DOI: 10.1515/bmt-2021-0025] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 04/12/2021] [Indexed: 11/15/2022]
Abstract
In this study, we propose a method for detecting obstructive sleep apnea (OSA) based on the features extracted from empirical mode decomposition (EMD) and the neural networks trained by particle swarm optimization (PSO) in the classification phase. After extracting the features from the intrinsic mode functions (IMF) of each heart rate variability (HRV) signal of each segment, these features were applied to the input of popular classifiers such as multi-layer perceptron neural networks (MLPNN), Naïve Bayes, linear discriminant analysis (LDA), k-nearest neighborhood (KNN), and support vector machines (SVM) were applied. The results show that the MLPNN learned with back propagation (BP) algorithm has a diagnostic accuracy of less than 90%, and this may be due to being derivative based property of the BP algorithm, which causes trapping in the local minima. For Improving MLPNN's performance, we used the PSO algorithm instead of the BP method in training part. Therefore, the MLPNN's accuracy improved from 89.36 to 97.66% after the application of the PSO algorithm. The proposed method has also reached to 97.78 and 97.96% in sensitivity and specificity, respectively. So, it can be concluded that the proposed method achieves better or comparable results when compared with the previous works in this field.
Collapse
Affiliation(s)
- Sajjad Afrakhteh
- Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran, 16846-13114, Iran
| | - Ahmad Ayatollahi
- Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran, 16846-13114, Iran
| | - Fatemeh Soltani
- Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran, 16846-13114, Iran
| |
Collapse
|
34
|
Bernardini A, Brunello A, Gigli GL, Montanari A, Saccomanno N. AIOSA: An approach to the automatic identification of obstructive sleep apnea events based on deep learning. Artif Intell Med 2021; 118:102133. [PMID: 34412849 DOI: 10.1016/j.artmed.2021.102133] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 06/23/2021] [Accepted: 06/24/2021] [Indexed: 12/31/2022]
Abstract
Obstructive Sleep Apnea Syndrome (OSAS) is the most common sleep-related breathing disorder. It is caused by an increased upper airway resistance during sleep, which determines episodes of partial or complete interruption of airflow. The detection and treatment of OSAS is particularly important in patients who suffered a stroke, because the presence of severe OSAS is associated with higher mortality, worse neurological deficits, worse functional outcome after rehabilitation, and a higher likelihood of uncontrolled hypertension. The gold standard test for diagnosing OSAS is polysomnography (PSG). Unfortunately, performing a PSG in an electrically hostile environment, like a stroke unit, on neurologically impaired patients is a difficult task; moreover, the number of strokes per day vastly outnumbers the availability of polysomnographs and dedicated healthcare professionals. Hence, a simple and automated recognition system to identify OSAS cases among acute stroke patients, relying on routinely recorded vital signs, is highly desirable. The vast majority of the work done so far focuses on data recorded in ideal conditions and highly selected patients, and thus it is hardly exploitable in real-life circumstances, where it would be of actual use. In this paper, we propose a novel convolutional deep learning architecture able to effectively reduce the temporal resolution of raw waveform data, like physiological signals, extracting key features that can be used for further processing. We exploit models based on such an architecture to detect OSAS events in stroke unit recordings obtained from the monitoring of unselected patients. Unlike existing approaches, annotations are performed at one-second granularity, allowing physicians to better interpret the model outcome. Results are considered to be satisfactory by the domain experts. Moreover, through tests run on a widely-used public OSAS dataset, we show that the proposed approach outperforms current state-of-the-art solutions.
Collapse
Affiliation(s)
- Andrea Bernardini
- Clinical Neurology Unit, Udine University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100 Udine, Italy.
| | - Andrea Brunello
- Department of Mathematics, Computer Science, and Physics, University of Udine, Via delle Scienze 206, 33100 Udine, Italy.
| | - Gian Luigi Gigli
- Clinical Neurology Unit, Udine University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100 Udine, Italy.
| | - Angelo Montanari
- Department of Mathematics, Computer Science, and Physics, University of Udine, Via delle Scienze 206, 33100 Udine, Italy.
| | - Nicola Saccomanno
- Department of Mathematics, Computer Science, and Physics, University of Udine, Via delle Scienze 206, 33100 Udine, Italy.
| |
Collapse
|
35
|
Classification of Obstructive Sleep Apnoea from single-lead ECG signals using convolutional neural and Long Short Term Memory networks. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102906] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
36
|
Obstructive sleep apnea event prediction using recurrence plots and convolutional neural networks (RP-CNNs) from polysomnographic signals. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102928] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
37
|
End-to-End Sleep Apnea Detection Using Single-Lead ECG Signal and 1-D Residual Neural Networks. J Med Biol Eng 2021. [DOI: 10.1007/s40846-021-00646-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
38
|
Diagnosis of Obstructive Sleep Apnea from ECG Signals Using Machine Learning and Deep Learning Classifiers. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11146622] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Obstructive sleep apnea (OSA) is a well-known sleep ailment. OSA mostly occurs due to the shortage of oxygen for the human body, which causes several symptoms (i.e., low concentration, daytime sleepiness, and irritability). Discovering the existence of OSA at an early stage can save lives and reduce the cost of treatment. The computer-aided diagnosis (CAD) system can quickly detect OSA by examining the electrocardiogram (ECG) signals. Over-serving ECG using a visual procedure is challenging for physicians, time-consuming, expensive, and subjective. In general, automated detection of the ECG signal’s arrhythmia is a complex task due to the complexity of the data quantity and clinical content. Moreover, ECG signals are usually affected by noise (i.e., patient movement and disturbances generated by electric devices or infrastructure), which reduces the quality of the collected data. Machine learning (ML) and Deep Learning (DL) gain a higher interest in health care systems due to its ability of achieving an excellent performance compared to traditional classifiers. We propose a CAD system to diagnose apnea events based on ECG in an automated way in this work. The proposed system follows the following steps: (1) remove noise from the ECG signal using a Notch filter. (2) extract nine features from the ECG signal (3) use thirteen ML and four types of DL models for the diagnosis of sleep apnea. The experimental results show that our proposed approach offers a good performance of DL classifiers to detect OSA. The proposed model achieves an accuracy of 86.25% in the validation stage.
Collapse
|
39
|
ECG Signal Modeling Using Volatility Properties: Its Application in Sleep Apnea Syndrome. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:4894501. [PMID: 34306589 PMCID: PMC8282402 DOI: 10.1155/2021/4894501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 05/21/2021] [Accepted: 06/14/2021] [Indexed: 11/30/2022]
Abstract
This study presents and evaluates the mathematical model to estimate the mean and variance of single-lead ECG signals in sleep apnea syndrome. Our objective is to use the volatility property of the ECG signal for modeling. ECG signal is a stochastic signal whose mean and variance are time-varying. So, we propose to decompose this nonstationarity into two additive components; a homoscedastic Autoregressive Integrated Moving Average (ARIMA) and a heteroscedastic time series in terms of Exponential Generalized Autoregressive Conditional Heteroskedasticity (EGARCH), where the former captures the linearity property and the latter the nonlinear characteristics of the ECG signal. First, ECG signals are segmented into one-minute segments. The heteroskedasticity property is then examined through various tests such as the ARCH/GARCH test, kurtosis, skewness, and histograms. Next, the ARIMA model is applied to signals as a linear model and EGARCH as a nonlinear model. The appropriate orders of models are estimated by using the Bayesian Information Criterion (BIC). We assess the effectiveness of our model in terms of mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), and mean absolute percentage error (MAPE). The data in this article is obtained from the Physionet Apnea-ECG database. Results show that the ARIMA-EGARCH model performs better than other models for modeling both apneic and normal ECG signals in sleep apnea syndrome.
Collapse
|
40
|
Obstructive sleep apnea screening from unprocessed ECG signals using statistical modelling. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102685] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
41
|
Rahul J, Sora M, Sharma LD. Dynamic thresholding based efficient QRS complex detection with low computational overhead. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102519] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
42
|
Niroshana SMI, Zhu X, Nakamura K, Chen W. A fused-image-based approach to detect obstructive sleep apnea using a single-lead ECG and a 2D convolutional neural network. PLoS One 2021; 16:e0250618. [PMID: 33901251 PMCID: PMC8075238 DOI: 10.1371/journal.pone.0250618] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 04/09/2021] [Indexed: 11/18/2022] Open
Abstract
Obstructive sleep apnea (OSA) is a common chronic sleep disorder that disrupts breathing during sleep and is associated with many other medical conditions, including hypertension, coronary heart disease, and depression. Clinically, the standard for diagnosing OSA involves nocturnal polysomnography (PSG). However, this requires expert human intervention and considerable time, which limits the availability of OSA diagnosis in public health sectors. Therefore, electrocardiogram (ECG)-based methods for OSA detection have been proposed to automate the polysomnography procedure and reduce its discomfort. So far, most of the proposed approaches rely on feature engineering, which calls for advanced expert knowledge and experience. This paper proposes a novel fused-image-based technique that detects OSA using only a single-lead ECG signal. In the proposed approach, a convolutional neural network extracts features automatically from images created with one-minute ECG segments. The proposed network comprises 37 layers, including four residual blocks, a dense layer, a dropout layer, and a soft-max layer. In this study, three time-frequency representations, namely the scalogram, the spectrogram, and the Wigner-Ville distribution, were used to investigate the effectiveness of the fused-image-based approach. We found that blending scalogram and spectrogram images further improved the system's discriminative characteristics. Seventy ECG recordings from the PhysioNet Apnea-ECG database were used to train and evaluate the proposed model using 10-fold cross validation. The results of this study demonstrated that the proposed classifier can perform OSA detection with an average accuracy, recall, and specificity of 92.4%, 92.3%, and 92.6%, respectively, for the fused spectral images.
Collapse
Affiliation(s)
- S. M. Isuru Niroshana
- Biomedical Information Engineering Lab, The University of Aizu, Aizuwakamatsu, Fukushima, Japan
| | - Xin Zhu
- Biomedical Information Engineering Lab, The University of Aizu, Aizuwakamatsu, Fukushima, Japan
| | - Keijiro Nakamura
- Division of Cardiovascular Medicine, Ohashi Medical Center, Toho University, Meguro, Tokyo, Japan
| | - Wenxi Chen
- Biomedical Information Engineering Lab, The University of Aizu, Aizuwakamatsu, Fukushima, Japan
| |
Collapse
|
43
|
Zhang J, Tang Z, Gao J, Lin L, Liu Z, Wu H, Liu F, Yao R. Automatic Detection of Obstructive Sleep Apnea Events Using a Deep CNN-LSTM Model. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2021; 2021:5594733. [PMID: 33859679 PMCID: PMC8009718 DOI: 10.1155/2021/5594733] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/05/2021] [Accepted: 03/13/2021] [Indexed: 01/16/2023]
Abstract
Obstructive sleep apnea (OSA) is a common sleep-related respiratory disorder. Around the world, more and more people are suffering from OSA. Because of the limitation of monitor equipment, many people with OSA remain undetected. Therefore, we propose a sleep-monitoring model based on single-channel electrocardiogram using a convolutional neural network (CNN), which can be used in portable OSA monitor devices. To learn different scale features, the first convolution layer comprises three types of filters. The long short-term memory (LSTM) is used to learn the long-term dependencies such as the OSA transition rules. The softmax function is connected to the final fully connected layer to obtain the final decision. To detect a complete OSA event, the raw ECG signals are segmented by a 10 s overlapping sliding window. The proposed model is trained with the segmented raw signals and is subsequently tested to evaluate its event detection performance. According to experiment analysis, the proposed model exhibits Cohen's kappa coefficient of 0.92, a sensitivity of 96.1%, a specificity of 96.2%, and an accuracy of 96.1% with respect to the Apnea-ECG dataset. The proposed model is significantly higher than the results from the baseline method. The results prove that our approach could be a useful tool for detecting OSA on the basis of a single-lead ECG.
Collapse
Affiliation(s)
- Junming Zhang
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
- Henan Key Laboratory of Smart Lighting, Zhumadian, Henan 463000, China
- Henan Joint International Research Laboratory of Behavior Optimization Control for Smart Robots, Zhumadian, Henan 463000, China
- Zhumadian Artificial Intelligence & Medical Engineering Technical Research Centre, Zhumadian, Henan 463000, China
- Academy of Industry Innovation and Development, Huanghuai University, Zhumadian, Henan 463000, China
| | - Zhen Tang
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
| | - Jinfeng Gao
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
- Henan Key Laboratory of Smart Lighting, Zhumadian, Henan 463000, China
| | - Li Lin
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
| | - Zhiliang Liu
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
| | - Haitao Wu
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
- Henan Key Laboratory of Smart Lighting, Zhumadian, Henan 463000, China
| | - Fang Liu
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
- Henan Joint International Research Laboratory of Behavior Optimization Control for Smart Robots, Zhumadian, Henan 463000, China
| | - Ruxian Yao
- College of Information Engineering, Huanghuai University, Zhumadian, Henan 463000, China
- Henan Key Laboratory of Smart Lighting, Zhumadian, Henan 463000, China
| |
Collapse
|
44
|
Sharan RV, Berkovsky S, Xiong H, Coiera E. ECG-Derived Heart Rate Variability Interpolation and 1-D Convolutional Neural Networks for Detecting Sleep Apnea. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:637-640. [PMID: 33018068 DOI: 10.1109/embc44109.2020.9175998] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Feature extraction from ECG-derived heart rate variability signal has shown to be useful in classifying sleep apnea. In earlier works, time-domain features, frequency-domain features, and a combination of the two have been used with classifiers such as logistic regression and support vector machines. However, more recently, deep learning techniques have outperformed these conventional feature engineering and classification techniques in various applications. This work explores the use of convolutional neural networks (CNN) for detecting sleep apnea segments. CNN is an image classification technique that has shown robust performance in various signal classification applications. In this work, we use it to classify one-dimensional heart rate variability signal, thereby utilizing a one-dimensional CNN (1-D CNN). The proposed technique resizes the raw heart rate variability data to a common dimension using cubic interpolation and uses it as a direct input to the 1-D CNN, without the need for feature extraction and selection. The performance of the method is evaluated on a dataset of 70 overnight ECG recordings, with 35 recordings used for training the model and 35 for testing. The proposed method achieves an accuracy of 88.23% (AUC=0.9453) in detecting sleep apnea epochs, outperforming several baseline techniques.
Collapse
|
45
|
Association of decreasing hemoglobin levels with the incidence of acute kidney injury after percutaneous coronary intervention: a prospective multi-center study. Heart Vessels 2020; 36:330-336. [PMID: 33034713 DOI: 10.1007/s00380-020-01706-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 09/18/2020] [Indexed: 10/23/2022]
Abstract
Acute kidney injury (AKI) is common in patients undergoing percutaneous coronary intervention (PCI). One risk factor for AKI is periprocedural hemoglobin drop level (> 3 g/dL); however, whether the relationship between hemoglobin drop and AKI is linear or nonlinear remains unknown. We aimed to investigate the relationship between periprocedural hemoglobin drop and AKI after PCI. We evaluated 14,273 consecutive patients undergoing PCI between September 2008 and March 2019. AKI was defined as an absolute or a relative increase in serum creatinine level of 0.3 mg/dL or 50%, respectively. Restricted cubic spline was constructed to assess the association between hemoglobin drop and AKI by logistic regression and machine learning (ML) models, which were used to predict the risk of AKI. The patients' mean age was 68.4 ± 11.6 years; the AKI incidence was 10.5% (N = 1499). An absolute > 3 g/dL or 20% relative decrease in hemoglobin level was an independent predictor of AKI incidence (odds ratio, OR [95% confidence interval, CI]: 2.24 [1.92-2.61], P < 0.001; 2.35 [2.04-2.71], P < 0.001, respectively). An adjusted restricted cubic spline demonstrated that absolute/relative decrease in hemoglobin was linearly associated with AKI. Logistic and ML models with absolute/relative hemoglobin changes were comparable while estimating the risk of AKI (absolute area under the curve [AUC] (logistic):0.826, AUC (ML): 0.820; relative AUC (logistic): 0.818, AUC (ML): 0.816). An absolute/relative decrease in periprocedural hemoglobin after PCI was linearly associated with AKI. Detection of a relative/absolute decrease in hemoglobin may help clinicians identify individuals as high risk for AKI after PCI.
Collapse
|
46
|
Detection of Abnormal Respiratory Events with Single Channel ECG and Hybrid Machine Learning Model in Patients with Obstructive Sleep Apnea. Ing Rech Biomed 2020. [DOI: 10.1016/j.irbm.2020.05.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
47
|
Zarei A, Mohammadzadeh Asl B. Performance evaluation of the spectral autocorrelation function and autoregressive models for automated sleep apnea detection using single-lead ECG signal. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 195:105626. [PMID: 32634646 DOI: 10.1016/j.cmpb.2020.105626] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Accepted: 06/21/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE This paper addresses the automated recognition of obstructive sleep apnea (OSA) from the analysis of single-lead ECG signals. This is one of the most important problems that is, critical to the realization of monitoring patients with sleep apnea. METHODS In the present study, a novel solution based on autoregressive (AR) modeling of the single-lead ECG, and spectral autocorrelation function as an ECG feature extraction method is presented. The more effective features are opted by sequential forward feature selection (SFFS) technique and fed into the random forest for binary classification between the apnea and normal events. RESULTS Experimental results on Apnea-ECG database proved that the introduced algorithm resulted in an accuracy of 93.90% (sensitivity of 92.26% and specificity of 94.92%) in per-segment classification, which outperforms the other cutting-edge automatic OSA recognition techniques. Moreover, the proposed algorithm provided an accuracy of 97.14% (sensitivity of 95.65% and specificity of 100%) in discrimination of apnea patients from the normal subjects, which is comparable to the traditional and existing approaches. CONCLUSIONS This study suggests that automatic OSA recognition from single-lead ECG signals is possible, which can be used as an inexpensive and low complexity burden alternative to more conventional methods such as Polysomnography.
Collapse
Affiliation(s)
- Asghar Zarei
- Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran
| | | |
Collapse
|
48
|
Rahul J, Sora M, Sharma LD. Exploratory data analysis based efficient QRS-complex detection technique with minimal computational load. Phys Eng Sci Med 2020; 43:1049-1067. [PMID: 32734450 DOI: 10.1007/s13246-020-00906-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 07/14/2020] [Indexed: 02/07/2023]
Abstract
Detection of QRS-complex in the electrocardiogram (ECG) plays a decisive role in cardiac disorder detection. We face many challenges in terms of powerline interference, baseline drift, and abnormal varying peaks. In this work, we propose an exploratory data analysis (EDA) based efficient QRS-complex detection technique with minimal computational load. This paper includes median and moving average filter for pre-processing of the ECG. The peak of filtered ECG is enhanced to third power of the signal. The root mean square (rms) of the signal is estimated for the decision making rule. This technique adapted the new concept for isoelectric line identification and EDA based QRS-complex detection. In this paper, total 10,70,981 beats were used for validation from MIT BIH-Arrhythmia Database (MIT-BIH), Fantasia Database (FDB), European ST-T database (ESTD), a self recorded dataset (SDB), and fetal ECG database (FTDB). Overall sensitivity of 99.65 % and positive predictivity rate of 99.84 % have been achieved. The proposed technique doesn't require selection, setting, and training for QRS-complex detection. Thus, this paper presents a QRS-complex detection technique based on simple decision rules.
Collapse
Affiliation(s)
- Jagdeep Rahul
- Department of Electronics and Communication Engineering, Rajiv Gandhi University, Itanagar, India.
| | - Marpe Sora
- Department of Computer Science and Engineering, Rajiv Gandhi University, Itanagar, India
| | - Lakhan Dev Sharma
- School of Electronics Engineering, VIT-AP University, Amaravati, India
| |
Collapse
|
49
|
A Sleep Apnea Detection System Based on a One-Dimensional Deep Convolution Neural Network Model Using Single-Lead Electrocardiogram. SENSORS 2020; 20:s20154157. [PMID: 32722630 PMCID: PMC7435835 DOI: 10.3390/s20154157] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/17/2020] [Accepted: 07/24/2020] [Indexed: 11/30/2022]
Abstract
Many works in recent years have been focused on developing a portable and less expensive system for diagnosing patients with obstructive sleep apnea (OSA), instead of using the inconvenient and expensive polysomnography (PSG). This study proposes a sleep apnea detection system based on a one-dimensional (1D) deep convolutional neural network (CNN) model using the single-lead 1D electrocardiogram (ECG) signals. The proposed CNN model consists of 10 identical CNN-based feature extraction layers, a flattened layer, 4 identical classification layers mainly composed of fully connected networks, and a softmax classification layer. Thirty-five released and thirty-five withheld ECG recordings from the MIT PhysioNet Apnea-ECG Database were applied to train the proposed CNN model and validate its accuracy for the detection of the apnea events. The results show that the proposed model achieves 87.9% accuracy, 92.0% specificity, and 81.1% sensitivity for per-minute apnea detection, and 97.1% accuracy, 100% specificity, and 95.7% sensitivity for per-recording classification. The proposed model improves the accuracy of sleep apnea detection in comparison with several feature-engineering-based and feature-learning-based approaches.
Collapse
|
50
|
Zarei A, Asl BM. Automatic classification of apnea and normal subjects using new features extracted from HRV and ECG-derived respiration signals. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.101927] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|