1
|
Kataoka H, Miyata S, Ehara K. Simultaneous Determination of Tobacco Smoke Exposure and Stress Biomarkers in Saliva Using In-Tube SPME and LC-MS/MS for the Analysis of the Association between Passive Smoking and Stress. Molecules 2024; 29:4157. [PMID: 39275005 PMCID: PMC11397470 DOI: 10.3390/molecules29174157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 08/24/2024] [Accepted: 08/31/2024] [Indexed: 09/16/2024] Open
Abstract
Passive smoking from environmental tobacco smoke not only increases the risk of lung cancer and cardiovascular disease but may also be a stressor triggering neuropsychiatric and other disorders. To prevent these diseases, understanding the relationship between passive smoking and stress is vital. In this study, we developed a simple and sensitive method to simultaneously measure nicotine (Nic) and cotinine (Cot) as tobacco smoke exposure biomarkers, and cortisol (CRT), serotonin (5-HT), melatonin (MEL), dopamine (DA), and oxytocin (OXT) as stress-related biomarkers. These were extracted and concentrated from saliva by in-tube solid-phase microextraction (IT-SPME) using a Supel-Q PLOT capillary as the extraction device, then separated and detected within 6 min by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using a Kinetex Biphenyl column (Phenomenex Inc., Torrance, CA, USA). Limits of detection (S/N = 3) for Nic, Cot, CRT, 5-HT, MEL, DA, and OXT were 0.22, 0.12, 0.78, 0.39, 0.45, 1.4, and 3.7 pg mL-1, respectively, with linearity of calibration curves in the range of 0.01-25 ng mL-1 using stable isotope-labeled internal standards. Intra- and inter-day reproducibilities were under 7.9% and 14.6% (n = 5) relative standard deviations, and compound recoveries in spiked saliva samples ranged from 82.1 to 106.6%. In thirty nonsmokers, Nic contents positively correlated with CRT contents (R2 = 0.5264, n = 30), while no significant correlation was found with other biomarkers. The standard deviation of intervals between normal beats as the standard measure of heart rate variability analysis negatively correlated with CRT contents (R2 = 0.5041, n = 30). After passive smoke exposure, Nic levels transiently increased, Cot and CRT levels rose over time, and 5-HT, DA, and OXT levels decreased. These results indicate tobacco smoke exposure acts as a stressor in nonsmokers.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Okayama 703-8516, Japan
| | - Saori Miyata
- School of Pharmacy, Shujitsu University, Okayama 703-8516, Japan
| | - Kentaro Ehara
- School of Pharmacy, Shujitsu University, Okayama 703-8516, Japan
| |
Collapse
|
2
|
Bester M, Nichting TJ, Joshi R, Aissati L, Oei GS, Mischi M, van Laar JOEH, Vullings R. Changes in Maternal Heart Rate Variability and Photoplethysmography Morphology after Corticosteroid Administration: A Prospective, Observational Study. J Clin Med 2024; 13:2442. [PMID: 38673715 PMCID: PMC11051424 DOI: 10.3390/jcm13082442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 04/28/2024] Open
Abstract
Background: Owing to the association between dysfunctional maternal autonomic regulation and pregnancy complications, assessing non-invasive features reflecting autonomic activity-e.g., heart rate variability (HRV) and the morphology of the photoplethysmography (PPG) pulse wave-may aid in tracking maternal health. However, women with early pregnancy complications typically receive medication, such as corticosteroids, and the effect of corticosteroids on maternal HRV and PPG pulse wave morphology is not well-researched. Methods: We performed a prospective, observational study assessing the effect of betamethasone (a commonly used corticosteroid) on non-invasively assessed features of autonomic regulation. Sixty-one women with an indication for betamethasone were enrolled and wore a wrist-worn PPG device for at least four days, from which five-minute measurements were selected for analysis. A baseline measurement was selected either before betamethasone administration or sufficiently thereafter (i.e., three days after the last injection). Furthermore, measurements were selected 24, 48, and 72 h after betamethasone administration. HRV features in the time domain and frequency domain and describing heart rate (HR) complexity were calculated, along with PPG morphology features. These features were compared between the different days. Results: Maternal HR was significantly higher and HRV features linked to parasympathetic activity were significantly lower 24 h after betamethasone administration. Features linked to sympathetic activity remained stable. Furthermore, based on the PPG morphology features, betamethasone appears to have a vasoconstrictive effect. Conclusions: Our results suggest that administering betamethasone affects maternal autonomic regulation and cardiovasculature. Researchers assessing maternal HRV in complicated pregnancies should schedule measurements before or sufficiently after corticosteroid administration.
Collapse
Affiliation(s)
- Maretha Bester
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Patient Care and Monitoring, Philips Research, 5656 AE Eindhoven, The Netherlands
| | - Thomas J. Nichting
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, 5504 DB Veldhoven, The Netherlands
| | - Rohan Joshi
- Patient Care and Monitoring, Philips Research, 5656 AE Eindhoven, The Netherlands
| | - Lamyae Aissati
- Faculty of Health, Medicine and Life Science, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Guid S. Oei
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, 5504 DB Veldhoven, The Netherlands
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| | - Judith O. E. H. van Laar
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, 5504 DB Veldhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| |
Collapse
|
3
|
Argota Sánchez-Vaquerizo J, Hausladen CI, Mahajan S, Matter M, Siebenmann M, van Eggermond MAB, Helbing D. A virtual reality experiment to study pedestrian perception of future street scenarios. Sci Rep 2024; 14:4571. [PMID: 38403717 PMCID: PMC10894882 DOI: 10.1038/s41598-024-55073-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 02/20/2024] [Indexed: 02/27/2024] Open
Abstract
The current allocation of street space is based on expected vehicular peak-hour flows. Flexible and adaptive use of this space can respond to changing needs. To evaluate the acceptability of flexible street layouts, several urban environments were designed and implemented in virtual reality. Participants explored these designs in immersive virtual reality in a [Formula: see text] mixed factorial experiment, in which we analysed self-reported, behavioural and physiological responses from participants. Distinct communication strategies were varied between subjects. Participants' responses reveal a preference for familiar solutions. Unconventional street layouts are less preferred, perceived as unsafe and cause a measurably greater stress response. Furthermore, information provision focusing on comparisons lead participants to focus primarily on the drawbacks, instead of the advantages of novel scenarios. When being able to freely express thoughts and opinions, participants are focused more on the impact of space design on behaviour rather than the objective physical features themselves. Especially, this last finding suggests that it is vital to develop new street scenarios in an inclusive and democratic way: the success of innovating urban spaces depends on how well the vast diversity of citizens' needs is considered and met.
Collapse
Affiliation(s)
| | - Carina I Hausladen
- ETH Zürich, Computational Social Science, 8092, Zurich, Switzerland
- California Institute of Technology, Behavioral Economics, Pasadena, CA, 91125, USA
| | - Sachit Mahajan
- ETH Zürich, Computational Social Science, 8092, Zurich, Switzerland
| | - Marc Matter
- ETH Zürich, Computational Social Science, 8092, Zurich, Switzerland
| | | | | | - Dirk Helbing
- ETH Zürich, Computational Social Science, 8092, Zurich, Switzerland
- Complexity Science Hub, 1080, Vienna, Austria
| |
Collapse
|
4
|
Lu L, Zhu T, Morelli D, Creagh A, Liu Z, Yang J, Liu F, Zhang YT, Clifton DA. Uncertainties in the Analysis of Heart Rate Variability: A Systematic Review. IEEE Rev Biomed Eng 2024; 17:180-196. [PMID: 37186539 DOI: 10.1109/rbme.2023.3271595] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Heart rate variability (HRV) is an important metric with a variety of applications in clinical situations such as cardiovascular diseases, diabetes mellitus, and mental health. HRV data can be potentially obtained from electrocardiography and photoplethysmography signals, then computational techniques such as signal filtering and data segmentation are used to process the sampled data for calculating HRV measures. However, uncertainties arising from data acquisition, computational models, and physiological factors can lead to degraded signal quality and affect HRV analysis. Therefore, it is crucial to address these uncertainties and develop advanced models for HRV analysis. Although several reviews of HRV analysis exist, they primarily focus on clinical applications, trends in HRV methods, or specific aspects of uncertainties such as measurement noise. This paper provides a comprehensive review of uncertainties in HRV analysis, quantifies their impacts, and outlines potential solutions. To the best of our knowledge, this is the first study that presents a holistic review of uncertainties in HRV methods and quantifies their impacts on HRV measures from an engineer's perspective. This review is essential for developing robust and reliable models, and could serve as a valuable future reference in the field, particularly for dealing with uncertainties in HRV analysis.
Collapse
|
5
|
Chao-Écija A, López-González MV, Dawid-Milner MS. CardioRVAR: A New R Package and Shiny Application for the Evaluation of Closed-Loop Cardiovascular Interactions. BIOLOGY 2023; 12:1438. [PMID: 37998037 PMCID: PMC10669071 DOI: 10.3390/biology12111438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/25/2023] [Accepted: 10/27/2023] [Indexed: 11/25/2023]
Abstract
CardioRVAR is a new R package designed for the complete evaluation of closed-loop cardiovascular interactions and baroreflex sensitivity estimated from continuous non-invasive heart rate and blood pressure recordings. In this work, we highlight the importance of this software tool in the context of human cardiovascular and autonomic neurophysiology. A summary of the main algorithms that CardioRVAR uses are reviewed, and the workflow of this package is also discussed. We present the results obtained from this tool after its application in three clinical settings. These results support the potential clinical and scientific applications of this tool. The open-source tool can be downloaded from a public GitHub repository, as well as its specific Shiny application, CardioRVARapp. The open-source nature of the tool may benefit the future continuation of this work.
Collapse
Affiliation(s)
- Alvaro Chao-Écija
- Autonomic Nervous System Unit, CIMES, School of Medicine, University of Málaga, 29071 Malaga, Spain; (A.C.-É.); (M.V.L.-G.)
| | - Manuel Víctor López-González
- Autonomic Nervous System Unit, CIMES, School of Medicine, University of Málaga, 29071 Malaga, Spain; (A.C.-É.); (M.V.L.-G.)
- Biomedical Research Institute of Málaga (IBIMA), 29590 Malaga, Spain
| | - Marc Stefan Dawid-Milner
- Autonomic Nervous System Unit, CIMES, School of Medicine, University of Málaga, 29071 Malaga, Spain; (A.C.-É.); (M.V.L.-G.)
- Biomedical Research Institute of Málaga (IBIMA), 29590 Malaga, Spain
| |
Collapse
|
6
|
Xu YY, Shih CH, You YT. Game Fun Prediction Based on Frequency Domain Physiological Signals: Observational Study. SENSORS (BASEL, SWITZERLAND) 2023; 23:7051. [PMID: 37631587 PMCID: PMC10458170 DOI: 10.3390/s23167051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 08/08/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023]
Abstract
Traditionally, the subjective questionnaire collected from game players is regarded as a primary tool to evaluate a video game. However, the subjective evaluation result may vary due to individual differences, and it is not easy to provide real-time feedback to optimize the user experience. This paper aims to develop an objective game fun prediction system. In this system, the wearables with photoplethysmography (PPG) sensors continuously measure the heartbeat signals of game players, and the frequency domain heart rate variability (HRV) parameters can be derived from the inter-beat interval (IBI) sequence. Frequency domain HRV parameters, such as low frequency(LF), high frequency(HF), and LF/HF ratio, highly correlate with the human's emotion and mental status. Most existing works on emotion measurement during a game adopt time domain physiological signals such as heart rate and facial electromyography (EMG). Time domain signals can be easily interfered with by noises and environmental effects. The main contributions of this paper include (1) regarding the curve transition and standard deviation of LF/HF ratio as the objective game fun indicators and (2) proposing a linear model using objective indicators for game fun score prediction. The self-built dataset in this study involves ten healthy participants, comprising 36 samples. According to the analytical results, the linear model's mean absolute error (MAE) was 4.16%, and the root mean square error (RMSE) was 5.07%. While integrating this prediction model with wearable-based HRV measurements, the proposed system can provide a solution to improve the user experience of video games.
Collapse
Affiliation(s)
- Yeong-Yuh Xu
- Department of Artificial Intelligence and Computer Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan;
| | - Chi-Huang Shih
- Department of Computer Science and Information Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan;
| | - Yan-Ting You
- Department of Computer Science and Information Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan;
| |
Collapse
|
7
|
Mejía-Mejía E, Kyriacou PA. Spectral analysis for pulse rate variability assessment from simulated photoplethysmographic signals. Front Physiol 2022; 13:966130. [PMID: 36569750 PMCID: PMC9780434 DOI: 10.3389/fphys.2022.966130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 11/29/2022] [Indexed: 12/13/2022] Open
Abstract
Introduction: Pulse rate variability (PRV) refers to the changes in pulse rate through time and is extracted from pulsatile signals such as the photoplethysmogram (PPG). Although PRV has been used as a surrogate of heart rate variability (HRV), which is measured from the electrocardiogram (ECG), these variables have been shown to have differences, and it has been hypothesised that these differences may arise from technical aspects that may affect the reliable extraction of PRV from PPG signals. Moreover, there are no guidelines for the extraction of PRV information from pulsatile signals. Aim: In this study, the extraction of frequency-domain information from PRV was studied, in order to establish the best performing combination of parameters and algorithms to obtain the spectral representation of PRV. Methods: PPG signals with varying and known PRV content were simulated, and PRV information was extracted from these signals. Several spectral analysis techniques with different parameters were applied, and absolute, relative and centroid-related frequency-domain indices extracted from each combination. Indices from extracted and known PRV were compared using factorial analyses and Kruskal-Wallis tests to determine which spectral analysis technique gave the best performing results. Results: It was found that using fast Fourier transform and the multiple signal classification (PMUSIC) algorithms gave the best results, combined with cubic spline interpolation and a frequency resolution of 0.0078 Hz for the former; and a linear interpolation with a frequency resolution as low as 1.22 × 10-4, as well as applying a fifth order model, for the latter. Discussion: Considering the lower complexity of FFT over PMUSIC, FFT should be considered as the appropriate technique to extract frequency-domain information from PRV signals.
Collapse
|
8
|
Girčys R, Kazanavičius E, Maskeliūnas R, Damaševičius R, Woźniak M. Wearable system for real-time monitoring of hemodynamic parameters: Implementation and evaluation. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.101873] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
9
|
Konstantinou P, Trigeorgi A, Georgiou C, Gloster AT, Panayiotou G, Karekla M. Comparing apples and oranges or different types of citrus fruits? Using wearable versus stationary devices to analyze psychophysiological data. Psychophysiology 2020; 57:e13551. [PMID: 32072653 DOI: 10.1111/psyp.13551] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 01/18/2020] [Accepted: 01/27/2020] [Indexed: 12/30/2022]
Abstract
Wearable devices capable of capturing psychophysiological signals are popular. However, such devices have, yet, to be established in experimental and clinical research. This study, therefore, compared psychophysiological data (skin conductance level (SCL), heart rate (HR), and heart rate variability (HRV)) captured with a wearable device (Microsoft band 2) to those of a stationary device (Biopac MP150), in an experimental pain induction paradigm. Additionally, the present study aimed to compare two analytical techniques of HRV psychophysiological data: traditional (i.e., peaks are detected and manually checked) versus automated analysis using Python programs. Forty-three university students (86% female; Mage = 21.37 years) participated in the cold pressor pain induction task. Results showed that the majority of the correlations between the two devices for the mean HR were significant and strong (rs > .80) both during baseline and experimental phases. For the time-domain measure of mean RR (function of autonomic influences) of HRV, the correlations between the two devices at baseline were almost perfect (rs = .99), whereas at the experimental phase were significantly strong (rs > .74). However, no significant correlations were found for mean SCL (p> .05). Additionally, automated analysis led to similar features for HRV stationary data as the traditional analysis. Implications for data collection include the establishment of a methodology to compare stationary to mobile devices and a new, more cost efficient way of collecting psychophysiological data. Implications for data analysis include analyzing the data faster, with less effort and allowing for large amounts of data to be recorded.
Collapse
Affiliation(s)
| | - Andria Trigeorgi
- Department of Computer Science, University of Cyprus, Nicosia, Cyprus
| | - Chryssis Georgiou
- Department of Computer Science, University of Cyprus, Nicosia, Cyprus
| | - Andrew T Gloster
- Department of Psychology, University of Basel, Basel, Switzerland
| | | | - Maria Karekla
- Department of Psychology, University of Cyprus, Nicosia, Cyprus
| |
Collapse
|
10
|
|