1
|
Rodero C, Baptiste TMG, Barrows RK, Keramati H, Sillett CP, Strocchi M, Lamata P, Niederer SA. A systematic review of cardiac in-silico clinical trials. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2023; 5:032004. [PMID: 37360227 PMCID: PMC10286106 DOI: 10.1088/2516-1091/acdc71] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 05/26/2023] [Accepted: 06/07/2023] [Indexed: 06/28/2023]
Abstract
Computational models of the heart are now being used to assess the effectiveness and feasibility of interventions through in-silico clinical trials (ISCTs). As the adoption and acceptance of ISCTs increases, best practices for reporting the methodology and analysing the results will emerge. Focusing in the area of cardiology, we aim to evaluate the types of ISCTs, their analysis methods and their reporting standards. To this end, we conducted a systematic review of cardiac ISCTs over the period of 1 January 2012-1 January 2022, following the preferred reporting items for systematic reviews and meta-analysis (PRISMA). We considered cardiac ISCTs of human patient cohorts, and excluded studies of single individuals and those in which models were used to guide a procedure without comparing against a control group. We identified 36 publications that described cardiac ISCTs, with most of the studies coming from the US and the UK. In 75% of the studies, a validation step was performed, although the specific type of validation varied between the studies. ANSYS FLUENT was the most commonly used software in 19% of ISCTs. The specific software used was not reported in 14% of the studies. Unlike clinical trials, we found a lack of consistent reporting of patient demographics, with 28% of the studies not reporting them. Uncertainty quantification was limited, with sensitivity analysis performed in only 19% of the studies. In 97% of the ISCTs, no link was provided to provide easy access to the data or models used in the study. There was no consistent naming of study types with a wide range of studies that could potentially be considered ISCTs. There is a clear need for community agreement on minimal reporting standards on patient demographics, accepted standards for ISCT cohort quality control, uncertainty quantification, and increased model and data sharing.
Collapse
Affiliation(s)
- Cristobal Rodero
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Cardiac Modelling and Imaging Biomarkers (CMIB), Department of Biomedical Engineering and Imaging Sciences Department, King’s College London, London, United Kingdom
| | - Tiffany M G Baptiste
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Rosie K Barrows
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Hamed Keramati
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Cardiac Modelling and Imaging Biomarkers (CMIB), Department of Biomedical Engineering and Imaging Sciences Department, King’s College London, London, United Kingdom
| | - Charles P Sillett
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Marina Strocchi
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Pablo Lamata
- Cardiac Modelling and Imaging Biomarkers (CMIB), Department of Biomedical Engineering and Imaging Sciences Department, King’s College London, London, United Kingdom
| | - Steven A Niederer
- Cardiac Electro-Mechanics Research Group (CEMRG), National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Cardiac Electro-Mechanics Research Group (CEMRG), Department of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Turing Research and Innovation Cluster in Digital Twins (TRIC: DT), The Alan Turing Institute, London, United Kingdom
| |
Collapse
|
2
|
Qian S, Monaci S, Mendonca-Costa C, Campos F, Gemmell P, Zaidi HA, Rajani R, Whitaker J, Rinaldi CA, Bishop MJ. Additional coils mitigate elevated defibrillation threshold in right-sided implantable cardioverter defibrillator generator placement: a simulation study. Europace 2023; 25:euad146. [PMID: 37314196 PMCID: PMC10265967 DOI: 10.1093/europace/euad146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 05/13/2023] [Indexed: 06/15/2023] Open
Abstract
AIMS The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). METHODS AND RESULTS A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. CONCLUSION Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS.
Collapse
Affiliation(s)
- Shuang Qian
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| | - Sofia Monaci
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| | - Caroline Mendonca-Costa
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| | - Fernando Campos
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| | - Philip Gemmell
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| | - Hassan A Zaidi
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| | - Ronak Rajani
- Department of Cardiology, Guy’s and St Thomas’ Hospital, Westminster Bridge Rd, London SE1 7EH, UK
| | - John Whitaker
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
- Department of Cardiology, Guy’s and St Thomas’ Hospital, Westminster Bridge Rd, London SE1 7EH, UK
| | - Christopher A Rinaldi
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
- Department of Cardiology, Guy’s and St Thomas’ Hospital, Westminster Bridge Rd, London SE1 7EH, UK
| | - Martin J Bishop
- Department of Biomedical Engineering, School of Imaging Sciences and Biomedical Engineering, Kings College London, 4th North Wing, St Thomas’ Hospital, London SE1 7EH, UK
| |
Collapse
|
3
|
Galappaththige S, Gray RA, Costa CM, Niederer S, Pathmanathan P. Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar. PLoS Comput Biol 2022; 18:e1010541. [PMID: 36215228 PMCID: PMC9550052 DOI: 10.1371/journal.pcbi.1010541] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 09/02/2022] [Indexed: 11/07/2022] Open
Abstract
Reliable and robust simulation of individual patients using patient-specific models (PSMs) is one of the next frontiers for modeling and simulation (M&S) in healthcare. PSMs, which form the basis of digital twins, can be employed as clinical tools to, for example, assess disease state, predict response to therapy, or optimize therapy. They may also be used to construct virtual cohorts of patients, for in silico evaluation of medical product safety and/or performance. Methods and frameworks have recently been proposed for evaluating the credibility of M&S in healthcare applications. However, such efforts have generally been motivated by models of medical devices or generic patient models; how best to evaluate the credibility of PSMs has largely been unexplored. The aim of this paper is to understand and demonstrate the credibility assessment process for PSMs using patient-specific cardiac electrophysiological (EP) modeling as an exemplar. We first review approaches used to generate cardiac PSMs and consider how verification, validation, and uncertainty quantification (VVUQ) apply to cardiac PSMs. Next, we execute two simulation studies using a publicly available virtual cohort of 24 patient-specific ventricular models, the first a multi-patient verification study, the second investigating the impact of uncertainty in personalized and non-personalized inputs in a virtual cohort. We then use the findings from our analyses to identify how important characteristics of PSMs can be considered when assessing credibility with the approach of the ASME V&V40 Standard, accounting for PSM concepts such as inter- and intra-user variability, multi-patient and “every-patient” error estimation, uncertainty quantification in personalized vs non-personalized inputs, clinical validation, and others. The results of this paper will be useful to developers of cardiac and other medical image based PSMs, when assessing PSM credibility. Patient-specific models are computational models that have been personalized using data from a patient. After decades of research, recent computational, data science and healthcare advances have opened the door to the fulfilment of the enormous potential of such models, from truly personalized medicine to efficient and cost-effective testing of new medical products. However, reliability (credibility) of patient-specific models is key to their success, and there are currently no general guidelines for evaluating credibility of patient-specific models. Here, we consider how frameworks and model evaluation activities that have been developed for generic (not patient-specific) computational models, can be extended to patient specific models. We achieve this through a detailed analysis of the activities required to evaluate cardiac electrophysiological models, chosen as an exemplar field due to its maturity and the complexity of such models. This is the first paper on the topic of reliability of patient-specific models and will help pave the way to reliable and trusted patient-specific modeling across healthcare applications.
Collapse
Affiliation(s)
- Suran Galappaththige
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Richard A. Gray
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Caroline Mendonca Costa
- School of Biomedical Engineering & Imaging Sciences, King’s College London, London, United Kingdom
| | - Steven Niederer
- School of Biomedical Engineering & Imaging Sciences, King’s College London, London, United Kingdom
| | - Pras Pathmanathan
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
- * E-mail:
| |
Collapse
|
4
|
Qian S, Connolly A, Mendonca-Costa C, Campos F, Williams SE, Whitaker J, Rinaldi CA, Bishop MJ. An in-silico assessment of efficacy of two novel intra-cardiac electrode configurations versus traditional anti-tachycardia pacing therapy for terminating sustained ventricular tachycardia. Comput Biol Med 2021; 139:104987. [PMID: 34741904 PMCID: PMC8669079 DOI: 10.1016/j.compbiomed.2021.104987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/24/2021] [Accepted: 10/24/2021] [Indexed: 11/06/2022]
Abstract
The implanted cardioverter defibrillator (ICD) is an effective direct therapy for the treatment of cardiac arrhythmias, including ventricular tachycardia (VT). Anti-tachycardia pacing (ATP) is often applied by the ICD as the first mode of therapy, but is often found to be ineffective, particularly for fast VTs. In such cases, strong, painful and damaging backup defibrillation shocks are applied by the device. Here, we propose two novel electrode configurations: "bipolar" and "transmural" which both combine the concept of targeted shock delivery with the advantage of reduced energy required for VT termination. We perform an in silico study to evaluate the efficacy of VT termination by applying one single (low-energy) monophasic shock from each novel configuration, comparing with conventional ATP therapy. Both bipolar and transmural configurations are able to achieve a higher efficacy (93% and 85%) than ATP (45%), with energy delivered similar to and two orders of magnitudes smaller than conventional ICD defibrillation shocks, respectively. Specifically, the transmural configuration (which applies the shock vector directly across the scar substrate sustaining the VT) is most efficient, requiring typically less than 1 J shock energy to achieve a high efficacy. The efficacy of both bipolar and transmural configurations are higher when applied to slow VTs (100% and 97%) compared to fast VTs (57% and 29%). Both novel electrode configurations introduced are able to improve electrotherapy efficacy while reducing the overall number of required therapies and need for strong backup shocks.
Collapse
Affiliation(s)
- Shuang Qian
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom.
| | - Adam Connolly
- Invicro, Burlington Danes Building, Du Cane Rd, London, W12 0N, United Kingdom
| | - Caroline Mendonca-Costa
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| | - Fernando Campos
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| | - Steven E Williams
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| | - John Whitaker
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom; Department of Cardiology, Guy's and St Thomas' Hospital, London, SE1 7EH, United Kingdom
| | - Christopher A Rinaldi
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom; Department of Cardiology, Guy's and St Thomas' Hospital, London, SE1 7EH, United Kingdom
| | - Martin J Bishop
- School of Biomedical Engineering and Imaging Sciences, Rayne Institute, King's College London, 4th Floor, Lambeth Wing, St. Thomas' Hospital, Westminster Bridge Road, London, SE1 7EH, United Kingdom
| |
Collapse
|
5
|
Plank G, Loewe A, Neic A, Augustin C, Huang YL, Gsell MAF, Karabelas E, Nothstein M, Prassl AJ, Sánchez J, Seemann G, Vigmond EJ. The openCARP simulation environment for cardiac electrophysiology. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 208:106223. [PMID: 34171774 DOI: 10.1016/j.cmpb.2021.106223] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 05/28/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND AND OBJECTIVE Cardiac electrophysiology is a medical specialty with a long and rich tradition of computational modeling. Nevertheless, no community standard for cardiac electrophysiology simulation software has evolved yet. Here, we present the openCARP simulation environment as one solution that could foster the needs of large parts of this community. METHODS AND RESULTS openCARP and the Python-based carputils framework allow developing and sharing simulation pipelines which automate in silico experiments including all modeling and simulation steps to increase reproducibility and productivity. The continuously expanding openCARP user community is supported by tailored infrastructure. Documentation and training material facilitate access to this complementary research tool for new users. After a brief historic review, this paper summarizes requirements for a high-usability electrophysiology simulator and describes how openCARP fulfills them. We introduce the openCARP modeling workflow in a multi-scale example of atrial fibrillation simulations on single cell, tissue, organ and body level and finally outline future development potential. CONCLUSION As an open simulator, openCARP can advance the computational cardiac electrophysiology field by making state-of-the-art simulations accessible. In combination with the carputils framework, it offers a tailored software solution for the scientific community and contributes towards increasing use, transparency, standardization and reproducibility of in silico experiments.
Collapse
Affiliation(s)
- Gernot Plank
- Gottfried Schatz Research Center, Division of Biophysics, Medical University of Graz, Graz, Austria.
| | - Axel Loewe
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | | | - Christoph Augustin
- Gottfried Schatz Research Center, Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Yung-Lin Huang
- Institute for Experimental Cardiovascular Medicine, University Heart Center Freiburg. Bad Krozingen, Medical Center - University of Freiburg, Freiburg, Germany; Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Matthias A F Gsell
- Gottfried Schatz Research Center, Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Elias Karabelas
- Institute of Mathematics and Scientific Computing, University of Graz, Graz, Austria
| | - Mark Nothstein
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Anton J Prassl
- Gottfried Schatz Research Center, Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Jorge Sánchez
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Gunnar Seemann
- Institute for Experimental Cardiovascular Medicine, University Heart Center Freiburg. Bad Krozingen, Medical Center - University of Freiburg, Freiburg, Germany; Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Edward J Vigmond
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; Université Bordeaux, IMB, UMR 5251, F-33400 Talence, France
| |
Collapse
|
6
|
Monaci S, Gillette K, Puyol-Antón E, Rajani R, Plank G, King A, Bishop M. Automated Localization of Focal Ventricular Tachycardia From Simulated Implanted Device Electrograms: A Combined Physics-AI Approach. Front Physiol 2021; 12:682446. [PMID: 34276403 PMCID: PMC8281305 DOI: 10.3389/fphys.2021.682446] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 05/31/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Focal ventricular tachycardia (VT) is a life-threating arrhythmia, responsible for high morbidity rates and sudden cardiac death (SCD). Radiofrequency ablation is the only curative therapy against incessant VT; however, its success is dependent on accurate localization of its source, which is highly invasive and time-consuming. Objective: The goal of our study is, as a proof of concept, to demonstrate the possibility of utilizing electrogram (EGM) recordings from cardiac implantable electronic devices (CIEDs). To achieve this, we utilize fast and accurate whole torso electrophysiological (EP) simulations in conjunction with convolutional neural networks (CNNs) to automate the localization of focal VTs using simulated EGMs. Materials and Methods: A highly detailed 3D torso model was used to simulate ∼4000 focal VTs, evenly distributed across the left ventricle (LV), utilizing a rapid reaction-eikonal environment. Solutions were subsequently combined with lead field computations on the torso to derive accurate electrocardiograms (ECGs) and EGM traces, which were used as inputs to CNNs to localize focal sources. We compared the localization performance of a previously developed CNN architecture (Cartesian probability-based) with our novel CNN algorithm utilizing universal ventricular coordinates (UVCs). Results: Implanted device EGMs successfully localized VT sources with localization error (8.74 mm) comparable to ECG-based localization (6.69 mm). Our novel UVC CNN architecture outperformed the existing Cartesian probability-based algorithm (errors = 4.06 mm and 8.07 mm for ECGs and EGMs, respectively). Overall, localization was relatively insensitive to noise and changes in body compositions; however, displacements in ECG electrodes and CIED leads caused performance to decrease (errors 16-25 mm). Conclusion: EGM recordings from implanted devices may be used to successfully, and robustly, localize focal VT sources, and aid ablation planning.
Collapse
Affiliation(s)
| | - Karli Gillette
- Division of Biophysics, Medical University of Graz, Graz, Austria
| | | | | | - Gernot Plank
- Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Andrew King
- King’s College London, London, United Kingdom
| | | |
Collapse
|
7
|
His-bundle and left bundle pacing with optimized atrioventricular delay achieve superior electrical synchrony over endocardial and epicardial pacing in left bundle branch block patients. Heart Rhythm 2020; 17:1922-1929. [DOI: 10.1016/j.hrthm.2020.06.028] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 06/16/2020] [Accepted: 06/22/2020] [Indexed: 02/05/2023]
|
8
|
Corrado C, Avezzù A, Lee AWC, Mendoca Costa C, Roney CH, Strocchi M, Bishop M, Niederer SA. Using cardiac ionic cell models to interpret clinical data. WIREs Mech Dis 2020; 13:e1508. [PMID: 33027553 DOI: 10.1002/wsbm.1508] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 08/27/2020] [Accepted: 09/04/2020] [Indexed: 01/24/2023]
Abstract
For over 100 years cardiac electrophysiology has been measured in the clinic. The electrical signals that can be measured span from noninvasive ECG and body surface potentials measurements through to detailed invasive measurements of local tissue electrophysiology. These electrophysiological measurements form a crucial component of patient diagnosis and monitoring; however, it remains challenging to quantitatively link changes in clinical electrophysiology measurements to biophysical cellular function. Multi-scale biophysical computational models represent one solution to this problem. These models provide a formal framework for linking cellular function through to emergent whole organ function and routine clinical diagnostic signals. In this review, we describe recent work on the use of computational models to interpret clinical electrophysiology signals. We review the simulation of human cardiac myocyte electrophysiology in the atria and the ventricles and how these models are being used to link organ scale function to patient disease mechanisms and therapy response in patients receiving implanted defibrillators, \cardiac resynchronisation therapy or suffering from atrial fibrillation and ventricular tachycardia. There is a growing use of multi-scale biophysical models to interpret clinical data. This allows cardiologists to link clinical observations with cellular mechanisms to better understand cardiopathophysiology and identify novel treatment strategies. This article is categorized under: Cardiovascular Diseases > Computational Models Cardiovascular Diseases > Biomedical Engineering Cardiovascular Diseases > Molecular and Cellular Physiology.
Collapse
|
9
|
Gemmell PM, Gillette K, Balaban G, Rajani R, Vigmond EJ, Plank G, Bishop MJ. A computational investigation into rate-dependant vectorcardiogram changes due to specific fibrosis patterns in non-ischæmic dilated cardiomyopathy. Comput Biol Med 2020; 123:103895. [PMID: 32741753 PMCID: PMC7429989 DOI: 10.1016/j.compbiomed.2020.103895] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 06/12/2020] [Accepted: 06/27/2020] [Indexed: 01/13/2023]
Abstract
Patients with scar-associated fibrotic tissue remodelling are at greater risk of ventricular arrhythmic events, but current methods to detect the presence of such remodelling require invasive procedures. We present here a potential method to detect the presence, location and dimensions of scar using pacing-dependent changes in the vectorcardiogram (VCG). Using a clinically-derived whole-torso computational model, simulations were conducted at both slow and rapid pacing for a variety of scar patterns within the myocardium, with various VCG-derived metrics being calculated, with changes in these metrics being assessed for their ability to discern the presence and size of scar. Our results indicate that differences in the dipole angle at the end of the QRS complex and differences in the QRS area and duration may be used to predict scar properties. Using machine learning techniques, we were also able to predict the location of the scar to high accuracy, using only these VCG-derived rate-dependent changes as input. Such a non-invasive predictive tool for the presence of scar represents a potentially useful clinical tool for identifying patients at arrhythmic risk.
Collapse
Affiliation(s)
- Philip M Gemmell
- King's College London, St. Thomas' Hospital North Wing, London, SE1 7EH, UK.
| | - Karli Gillette
- Medical University of Graz, Division of Biophysics, Neue Stiftingtalstraße 6(MC1.D.)/IV, 8010 Graz, Austria
| | - Gabriel Balaban
- University of Oslo, Research Group for Biomedical Infomatics, Gaustadalléen 23B 0373 Oslo, Norway
| | - Ronak Rajani
- King's College London, St. Thomas' Hospital North Wing, London, SE1 7EH, UK
| | - Edward J Vigmond
- University of Bordeaux, IHU Liryc, Site Hopital Xavier Arnozan, Avenue de Haut-Leveque, 33604 Pessac, France
| | - Gernot Plank
- Medical University of Graz, Division of Biophysics, Neue Stiftingtalstraße 6(MC1.D.)/IV, 8010 Graz, Austria
| | - Martin J Bishop
- King's College London, St. Thomas' Hospital North Wing, London, SE1 7EH, UK
| |
Collapse
|
10
|
Niederer SA, Aboelkassem Y, Cantwell CD, Corrado C, Coveney S, Cherry EM, Delhaas T, Fenton FH, Panfilov AV, Pathmanathan P, Plank G, Riabiz M, Roney CH, dos Santos RW, Wang L. Creation and application of virtual patient cohorts of heart models. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2020; 378:20190558. [PMID: 32448064 PMCID: PMC7287335 DOI: 10.1098/rsta.2019.0558] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/06/2020] [Indexed: 05/21/2023]
Abstract
Patient-specific cardiac models are now being used to guide therapies. The increased use of patient-specific cardiac simulations in clinical care will give rise to the development of virtual cohorts of cardiac models. These cohorts will allow cardiac simulations to capture and quantify inter-patient variability. However, the development of virtual cohorts of cardiac models will require the transformation of cardiac modelling from small numbers of bespoke models to robust and rapid workflows that can create large numbers of models. In this review, we describe the state of the art in virtual cohorts of cardiac models, the process of creating virtual cohorts of cardiac models, and how to generate the individual cohort member models, followed by a discussion of the potential and future applications of virtual cohorts of cardiac models. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.
Collapse
Affiliation(s)
| | | | | | | | | | - E. M. Cherry
- Georgia Institute of Technology, Atlanta, GA, USA
| | - T. Delhaas
- Maastricht University, Maastricht, the Netherlands
| | - F. H. Fenton
- Georgia Institute of Technology, Atlanta, GA, USA
| | - A. V. Panfilov
- Ghent University, Gent, Belgium
- Laboratory of Computational Biology and Medicine, Ural Federal University, Ekaterinburg, Russia
| | - P. Pathmanathan
- Center for Devices and Radiological Health, U.S. Food and Administration, Rockville, MD, USA
| | - G. Plank
- Medical University of Graz, Graz, Austria
| | | | | | | | - L. Wang
- Rochester Institute of Technology, La JollaRochester, NY, USA
| |
Collapse
|
11
|
Neic A, Gsell MA, Karabelas E, Prassl AJ, Plank G. Automating image-based mesh generation and manipulation tasks in cardiac modeling workflows using Meshtool. SOFTWAREX 2020; 11:100454. [PMID: 32607406 PMCID: PMC7326605 DOI: 10.1016/j.softx.2020.100454] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Advanced cardiac modeling studies rely on the ability to generate and functionalize personalized in silico models from tomographic multi-label image stacks. Eventually, this is used for building virtual cohorts that capture the variability in size, shape, and morphology of individual hearts. Typical modeling workflows involve a multitude of interactive mesh manipulation steps, rendering model generation expensive. Meshtool is software specifically designed for automating all complex mesh manipulation tasks emerging in such workflows by implementing algorithms for tasks describable as operations on label fields and/or geometric features. We illustrate how Meshtool increases efficiency and reduces costs by offering an automatable, high performance mesh manipulation toolbox.
Collapse
Affiliation(s)
- Aurel Neic
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
- NumeriCor GmbH, Graz, Austria
| | - Matthias A.F. Gsell
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Elias Karabelas
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, London, United Kingdom
| | - Anton J. Prassl
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Gernot Plank
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
| |
Collapse
|