1
|
Sharma A, Mishra A, Chhabra M. Rapid measurement of bacterial contamination in water: A catalase responsive-electrochemical sensor. Heliyon 2024; 10:e26724. [PMID: 38434288 PMCID: PMC10906405 DOI: 10.1016/j.heliyon.2024.e26724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 02/19/2024] [Accepted: 02/19/2024] [Indexed: 03/05/2024] Open
Abstract
The present study describes the development of a potentiometric sensor for microbial monitoring in water based on catalase activity. The sensor comprises a MnO2-modified electrode that responds linearly to hydrogen peroxide (H2O2) from 0.16 M to 3.26 M. The electrode potential drops when the H2O2 solution is spiked with catalase or catalase-producing microorganisms that decompose H2O2. The sensor is responsive to different bacteria and their catalase activities. The electrochemical sensor exhibits a lower limit of detection (LOD) for Escherichia coli at 11 CFU/ml, Citrobacter youngae at 12 CFU/ml, and Pseudomonas aeruginosa at 23 CFU/ml. The sensor shows high sensitivity at 3.49, 3.02, and 4.24 mV/cm2dec for E. coli, C. youngae, and P. aeruginosa, respectively. The abiotic sensing electrode can be used multiple times without changing the response potential (up to 100 readings) with a shelf-life of over six months. The response time is a few seconds, with a total test time of 5 min. Additionally, the sensor effectively tested actual samples (drinking and grey water), which makes it a quick and reliable sensing tool. Therefore, the study offers a promising water monitoring tool with high sensitivity, stability, good detection limit, and minimum interference from other water contaminants.
Collapse
Affiliation(s)
| | | | - Meenu Chhabra
- Environmental Biotechnology Laboratory, Department of Bioscience and Bioengineering, Indian Institute of Technology Jodhpur (IITJ), Jodhpur, 342030, Rajasthan, India
| |
Collapse
|
2
|
Venegas CJ, Gutierrez FA, Reeves-McLaren N, Rivas GA, Ruiz-León D, Bollo S. In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide-An Evaluation of Co 2SnO 4/RGO Nanohybrids. MICROMACHINES 2023; 14:mi14051059. [PMID: 37241682 DOI: 10.3390/mi14051059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/04/2023] [Accepted: 05/14/2023] [Indexed: 05/28/2023]
Abstract
Nowadays, there is no doubt about the high electrocatalytic efficiency that is obtained when using hybrid materials between carbonaceous nanomaterials and transition metal oxides. However, the method to prepare them may involve differences in the observed analytical responses, making it necessary to evaluate them for each new material. The goal of this work was to obtain for the first time Co2SnO4 (CSO)/RGO nanohybrids via in situ and ex situ methods and to evaluate their performance in the amperometric detection of hydrogen peroxide. The electroanalytical response was evaluated in NaOH pH 12 solution using detection potentials of -0.400 V or 0.300 V for the reduction or oxidation of H2O2. The results show that for CSO there were no differences between the nanohybrids either by oxidation or by reduction, unlike what we previously observed with cobalt titanate hybrids, in which the in situ nanohybrid clearly had the best performance. On the other hand, no influence in the study of interferents and more stable signals were obtained when the reduction mode was used. In conclusion, for detecting hydrogen peroxide, any of the nanohybrids studied, i.e., in situ or ex situ, are suitable to be used, and more efficiency is obtained using the reduction mode.
Collapse
Affiliation(s)
- Constanza J Venegas
- Programa Institucional de Fomento a la Investigación, Desarrollo e Innovación, Universidad Tecnológica Metropolitana, Ignacio Valdivieso 2409, P.O. Box 8940577, San Joaquín 8320000, Santiago, Chile
| | - Fabiana A Gutierrez
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe 3000, Argentina
- Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz CP C1425FQB, Buenos Aires 2290, Argentina
| | - Nik Reeves-McLaren
- Department of Materials Science and Engineering, University of Sheffield, Sheffield S1 3JD, UK
| | - Gustavo A Rivas
- Instituto de Investigaciones en Físico-Química de Córdoba (INFIQC), Departamento de Físicoquímica, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba 5000, Argentina
| | - Domingo Ruiz-León
- Laboratorio de Fisicoquímica y Electroquímica del Estado Sólido, Facultad de Química y Biología, Universidad de Santiago de Chile, Av. Libertador Bernardo O'Higgins n◦ 3363, Estación Central 9160000, Santiago, Chile
| | - Soledad Bollo
- Centro de Investigación de Procesos Redox (CiPRex), Universidad de Chile, Sergio Livingstone Polhammer 1007, Independencia 8330015, Santiago, Chile
- Advanced Center for Chronic Diseases (ACCDiS), Universidad de Chile, Sergio Livingstone Polhammer 1007, Independencia 8330015, Santiago, Chile
| |
Collapse
|
3
|
Mohiuddin AK, Jeon S. Highly efficient Ag doped δ-MnO 2 decorated graphene: Comparison and application in electrochemical detection of H 2O 2. APPLIED SURFACE SCIENCE 2022; 592:153162. [PMID: 35370331 PMCID: PMC8959659 DOI: 10.1016/j.apsusc.2022.153162] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 03/18/2022] [Accepted: 03/19/2022] [Indexed: 06/14/2023]
Abstract
Cytotoxic H2O2 is an inevitable part of our life, even during this contemporary pandemic COVID-19. Personal protective equipment of the front line fighter against coronavirus could be sterilized easily by H2O2 for reuse. In this study, Ag doped δ-MnO2 nanorods supported graphene nanocomposite (denoted as Ag@δ-MnO2/G) was synthesized as a nonenzymatic electrochemical sensor for the sensitive detection of H2O2. The ternary nanocomposite has overcome the poor electrical conductivity of δ-MnO2 and also the severe aggregation of Ag NPs. Furthermore, δ-MnO2/G provided a rougher surface and large numbers of functional groups for doping more numbers of Ag atoms, which effectively modulate the electronic properties of the nanocomposite. As a result, electroactive surface area and electrical conductivity of Ag@δ-MnO2/G increased remarkably as well as excellent catalytic activity observed towards H2O2 reduction. The modified glassy carbon electrode exhibited fast amperometric response time (<2 s) in H2O2 determination. The limit of detection was calculated as 68 nM in the broad linear range (0.005-90.64 mM) with high sensitivity of 104.43 µA mM-1 cm-2. No significant interference, long-term stability, excellent reproducibility, satisfactory repeatability, practical applicability towards food samples and wastewater proved the efficiency of the proposed sensor.
Collapse
Affiliation(s)
- Abdul Kader Mohiuddin
- Department of Chemistry and Institute of Basic Science, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Seungwon Jeon
- Department of Chemistry and Institute of Basic Science, Chonnam National University, Gwangju 61186, Republic of Korea
| |
Collapse
|
4
|
Yang M, Wu Z, Wang X, Yin Z, Tan X, Zhao J. Facile preparation of MnO 2-TiO 2 nanotube arrays composite electrode for electrochemical detection of hydrogen peroxide. Talanta 2022; 244:123407. [PMID: 35366513 DOI: 10.1016/j.talanta.2022.123407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 12/16/2021] [Accepted: 03/23/2022] [Indexed: 01/10/2023]
Abstract
The MnO2-TNTA composite electrodes were obtained through depositing MnO2 into TiO2 nanotube arrays (TNTA) by successive ionic layer adsorption reaction (SILAR) and subsequent hydrothermal method. The MnO2-TNTA nanocomposites were used as electrochemical sensors for the detection of hydrogen peroxide (H2O2). The preparation conditions of MnO2-TNTA electrodes and test conditions affect the electrochemical detection performance significantly. The optimal conditions are listed as follows: the number of SILAR cycles, 6 times; KMnO4 solution temperature, 50 °C; supporting electrolyte, 0.5 M NaOH. Under these conditions, the MnO2-TNTA electrode exhibits the best performance for detecting H2O2. The optimized MnO2-TNTA electrode has a minimum detection limit of 0.6 μM (S/N = 3) and a linear range of 5 μM ∼ 13 mM, which is much superior to the previously-reported electrodes. Moreover, the optimized MnO2-TNTA electrode possesses high selectivity, excellent stability and good reproducibility in the detection of H2O2. When used in the determination of H2O2 content in actual samples including disinfectant and milk, it also shows good accuracy, ideal recovery (96.00% ∼ 102.67%) and high precision (RSD < 4.0%).
Collapse
Affiliation(s)
- Mengyao Yang
- School of Materials Science and Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Zhigang Wu
- School of Materials Science and Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Xixin Wang
- School of Materials Science and Engineering, Hebei University of Technology, Tianjin, 300130, China.
| | - Zekun Yin
- School of Materials Science and Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Xu Tan
- School of Materials Science and Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Jianling Zhao
- School of Materials Science and Engineering, Hebei University of Technology, Tianjin, 300130, China.
| |
Collapse
|
5
|
Wu T, Liang W, Lin Y. Facile synthesis of Cu−intercalated MnO2 nanoflakes cathode for enhanced energy storage in zinc−ion batteries. J Taiwan Inst Chem Eng 2022. [DOI: 10.1016/j.jtice.2021.104172] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
6
|
Keshari AS, Dubey P. Sucrose-assisted one step hydrothermal synthesis of MnCO3/Mn3O4 hybrid materials for electrochemical energy storage. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
7
|
Zeplin G, Neiva EG. One-pot green synthesis of graphene oxide/MnO2/polyaniline nanocomposites applied in aqueous and neutral supercapacitors and sensors. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115776] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
8
|
Li X, Xu M, Wu Q, Wei W, Liu X. Photolithographic 3D microarray electrode-based high-performance non-enzymatic H2O2 sensor. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
9
|
Dinesh M, Muthumalai K, Haldorai Y, Thangavelu Rajendra Kumar R. MoS
2
Nanosheets Decorated Multi‐walled Carbon Nanotube Composite Electrocatalyst for 4‐Nitrophenol Detection and Hydrogen Evolution Reaction. ELECTROANAL 2020. [DOI: 10.1002/elan.202060351] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Muthu Dinesh
- Advanced Materials and Devices Laboratory (AMDL) Department of Nanoscience and Technology Bharathiar University Coimbatore 641 046 Tamil Nadu India
| | - K. Muthumalai
- Advanced Materials and Devices Laboratory (AMDL) Department of Nanoscience and Technology Bharathiar University Coimbatore 641 046 Tamil Nadu India
| | - Yuvaraj Haldorai
- Advanced Materials and Devices Laboratory (AMDL) Department of Nanoscience and Technology Bharathiar University Coimbatore 641 046 Tamil Nadu India
| | - Ramasamy Thangavelu Rajendra Kumar
- Advanced Materials and Devices Laboratory (AMDL) Department of Nanoscience and Technology Bharathiar University Coimbatore 641 046 Tamil Nadu India
| |
Collapse
|
10
|
Non-enzymatic monitoring of hydrogen peroxide using novel nanosensor based on CoFe2O4@CdSeQD magnetic nanocomposite and rifampicin mediator. Anal Bioanal Chem 2020; 412:5053-5065. [DOI: 10.1007/s00216-019-02306-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 11/21/2019] [Accepted: 11/26/2019] [Indexed: 10/25/2022]
|