1
|
Chotkan KA, Alwayn IPJ, Hemke AC, Baranski A, Nijboer W, Pol RA, Braat AE. Ten Years of Quality Monitoring of Abdominal Organ Procurement in the Netherlands and Its Impact on Transplant Outcome. Transpl Int 2024; 37:12989. [PMID: 38919904 PMCID: PMC11197516 DOI: 10.3389/ti.2024.12989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 05/17/2024] [Indexed: 06/27/2024]
Abstract
In this study, 10 years of procurement quality monitoring data were analyzed to identify potential risk factors associated with procurement-related injury and their association with long-term graft survival. All deceased kidney, liver, and pancreas donors from 2012 to 2022 and their corresponding recipients in the Netherlands were retrospectively included. The incidence of procurement-related injuries and potential risk factors were analyzed. Of all abdominal organs procured, 23% exhibited procurement-related injuries, with a discard rate of 4.0%. In kidneys and livers, 23% of the grafts had procurement-related injury, with 2.5% and 4% of organs with procurement-related injury being discarded, respectively. In pancreas procurement, this was 27%, with a discard rate of 24%. Male donor gender and donor BMI >25 were significant risk factors for procurement-related injury in all three abdominal organs, whereas aberrant vascularization was significant only for the kidney and liver. In the multivariable Cox regression analyses, procurement-related injury was not a significant predictor for graft failure (kidney; HR 0.99, 95% CI 0.75-1.33, p = 0.99, liver; HR 0.92, 95% CI 0.66-1.28, p = 0.61, pancreas: HR 1.16; 95% CI 0.16-8.68, p = 0.88). The findings of this study suggest that transplant surgeons exhibited good decision-making skills in determining the acceptability and repairability of procurement-related injuries.
Collapse
Affiliation(s)
- K. A. Chotkan
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Dutch Transplant Foundation, Leiden, Netherlands
| | - I. P. J. Alwayn
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Transplant Center, Leiden University Medical Center, Leiden, Netherlands
| | - A. C. Hemke
- Dutch Transplant Foundation, Leiden, Netherlands
| | - A. Baranski
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Transplant Center, Leiden University Medical Center, Leiden, Netherlands
| | - W. Nijboer
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Transplant Center, Leiden University Medical Center, Leiden, Netherlands
| | - R. A. Pol
- Department of Surgery, Division of Transplantation, University Medical Center Groningen, Groningen, Netherlands
| | - A. E. Braat
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Transplant Center, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
2
|
Chotkan KA, Hilbrands LB, Putter H, Konjin C, Schaefer B, Beenen LF, Pol RA, Braat AE. Transplant Outcomes After Exposure of Deceased Kidney Donors to Contrast Medium. Transplantation 2024; 108:252-260. [PMID: 37728569 PMCID: PMC10718213 DOI: 10.1097/tp.0000000000004745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 05/18/2023] [Accepted: 05/31/2023] [Indexed: 09/21/2023]
Abstract
BACKGROUND The administration of contrast medium is associated with acute kidney injury; however, the effect of exposure of a deceased organ donor to contrast medium on kidney transplant outcomes has been poorly studied. METHODS A retrospective analysis of all deceased kidney donors between 2011 and 2021 and their corresponding recipients in the Netherlands was conducted. Multivariable analyses were performed to assess the associations between contrast medium exposure and delayed graft function (DGF)/graft survival. Linear mixed models were used to assess the differences in mean estimated glomerular filtration rate values in recipients 1 to 6 y after transplantation. RESULTS In total, 2177 donors and 3638 corresponding kidney graft recipients were included. Twenty-four percent of the donors (n = 520) were exposed to contrast medium, corresponding to 23% of recipients (n = 832). DGF was observed in 36% (n = 1321) and primary nonfunction in 3% (n = 122) of recipients. DGF rates for donation after brain death (DBD) and donation after circulatory death (DCD) donors showed no significant effect of contrast medium exposure ( P = 0.15 and P = 0.60 for DBD and DCD donors, respectively). In multivariable analyses, contrast medium administration was not significantly associated with a higher DGF risk (odds ratio 1.06; 95% confidence interval, 0.86-1.36; P = 0.63) nor was a significant predictor for death-censored graft failure (hazard ratio 1.01; 95% confidence interval, 0.77-1.33; P = 0.93). Linear mixed models showed no difference in mean estimated glomerular filtration rate values in recipients 1 to 6 y posttransplantation ( P = 0.78). CONCLUSIONS This study indicates that contrast medium administration in DBD and DCD donors has no negative effect on early and long-term kidney graft function.
Collapse
Affiliation(s)
- Kinita A. Chotkan
- Department of Surgery, Leiden University Medical Center, Leiden, the Netherlands
- Department of Organ and Tissue Donation, Dutch Transplantation Foundation, Leiden, the Netherlands
| | - Luuk B. Hilbrands
- Department of Nephrology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Hein Putter
- Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, the Netherlands
| | - Cynthia Konjin
- Department of Organ and Tissue Donation, Dutch Transplantation Foundation, Leiden, the Netherlands
| | - Brigitte Schaefer
- Department of Organ and Tissue Donation, Dutch Transplantation Foundation, Leiden, the Netherlands
| | - Ludo F.M. Beenen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands
| | - Robert A. Pol
- Department of Surgery, Division of Transplantation, University Medical Center Groningen, Groningen, the Netherlands
| | - Andries E. Braat
- Department of Surgery, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
3
|
Kudliński B, Trosiak M, Wojciech M, Zaborniak G, Kania J, Buczek A, Fedorowicz O, Myślak M. “A Comparative Analysis of the Number of Organ Retrievals in Relation to Potential Donation Qualifications in Populations of Patients From a Single Anesthesiology and Intensive Care Unit in 2017-2018”. Front Med (Lausanne) 2022; 9:930290. [PMID: 36059819 PMCID: PMC9429814 DOI: 10.3389/fmed.2022.930290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 06/13/2022] [Indexed: 11/21/2022] Open
Abstract
The population of patients declared as brain dead and qualified for organ donation is relatively low in Poland. The main causes of brain death include cerebral vascular diseases and brain trauma (54 and 34%, respectively, according to Poltransplant registry data). The number of organ procurements in Poland is constantly recorded on average at 14 donations per 1 million citizens (14/mln) in 2017 and 12 donations per one million in 2018. It is difficult to precisely define the number of patients who meet the criteria for brain death certification. The authors have retrospectively analyzed the medical data of 229 patients from 2017 and 2018 records with the aim of identifying potential organ donors among patients of the Intensive Care Unit (ICU) in the University Hospital in Western Poland. Brain death was suspected in 53 patients (23.14%). Brain imaging to confirm no cerebral flow (which is consistent with brain death) was performed in 17 patients (7.45%) and this, as a result, led to organ donation in 9 cases (3.93%). The factors identified as having a positive influence on organ donation included: daily thorough physical examination, (Glasgow Coma Scale) GCS assessment, depth and duration of sedation, ICU length of stay and early performance of a CT-angiogram.
Collapse
Affiliation(s)
- Bartosz Kudliński
- Department of Emergency Medicine, Anesthesiology and Intensive Care in University Hospital Named After K. Marcinkowski, Collegium Medicum University of Zielona Gora, Zielona Góra, Poland
- *Correspondence: Bartosz Kudliński
| | - Marta Trosiak
- Department of Anesthesiology and Intensive Care, University Hospital Named After K. Marcinkowski, Zielona Góra, Poland
| | - Magdalena Wojciech
- Department of Statisical Mathematics and Econometry, Faculty of Mathematics, Informatics and Econometry in University of Zielona Gora, Zielona Góra, Poland
| | - Gabriel Zaborniak
- Faculty of Mathematics, Informatics and Econometry in University of Zielona Gora, Zielona Góra, Poland
| | - Jagoda Kania
- Faculty of Medicine and Health Science, Collegium Medicum University of Zielona Gora, Zielona Góra, Poland
| | - Aleksandra Buczek
- Faculty of Medicine and Health Science, Collegium Medicum University of Zielona Gora, Zielona Góra, Poland
| | - Olga Fedorowicz
- Faculty of Medicine and Health Science, Collegium Medicum University of Zielona Gora, Zielona Góra, Poland
| | - Marek Myślak
- Department of Nephrology, Transplantology and Internal Medicine Clinic, Pomerian Medical University, Szczecin, Poland
| |
Collapse
|
4
|
Chotkan KA, Mensink JW, Pol RA, Van Der Kaaij NP, Beenen LFM, Nijboer WN, Schaefer B, Alwayn IPJ, Braat AE. Radiological Screening Methods in Deceased Organ Donation: An Overview of Guidelines Worldwide. Transpl Int 2022; 35:10289. [PMID: 35664428 PMCID: PMC9161442 DOI: 10.3389/ti.2022.10289] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 04/26/2022] [Indexed: 06/15/2023]
Abstract
Organ transplantation is performed worldwide, but policies regarding donor imaging are not uniform. An overview of the policies in different regions is missing. This study aims to investigate the various protocols worldwide on imaging in deceased organ donation. An online survey was created to determine the current policies. Competent authorities were approached to fill out the survey based on their current protocols. In total 32 of the 48 countries approached filled out the questionnaire (response rate 67%). In 16% of the countries no abdominal imaging is required prior to procurement. In 50%, abdominal ultrasound (US) is performed to screen the abdomen and in 19% an enhanced abdominal Computed Tomography (CT). In 15% of the countries both an unenhanced abdominal CT scan and abdominal US are performed. In 38% of the countries a chest radiographic (CXR) is performed to screen the thorax, in 28% only a chest CT, and in 34% both are performed. Policies regarding radiologic screening in deceased organ donors show a great variation between different countries. Consensus on which imaging method should be applied is missing. A uniform approach will contribute to quality and safety, justifying (inter)national exchange of organs.
Collapse
Affiliation(s)
- K. A. Chotkan
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Department of Organ and Tissue Donation, Dutch Transplant Foundation, Leiden, Netherlands
| | - J. W. Mensink
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Department of Organ and Tissue Donation, Dutch Transplant Foundation, Leiden, Netherlands
| | - R. A. Pol
- Department of Surgery, Division of Transplantation, University Medical Center Groningen, Groningen, Netherlands
| | - N. P. Van Der Kaaij
- Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht, Netherlands
| | - L. F. M. Beenen
- Department of Radiology, Amsterdam UMC, Amsterdam, Netherlands
| | - W. N. Nijboer
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Transplant Center, Leiden University Medical Center, Leiden, Netherlands
| | - B. Schaefer
- Department of Organ and Tissue Donation, Dutch Transplant Foundation, Leiden, Netherlands
| | - I. P. J. Alwayn
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
- Transplant Center, Leiden University Medical Center, Leiden, Netherlands
| | - A. E. Braat
- Department of Surgery, Division of Transplantation, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
5
|
En Bloc Transplantation of Horseshoe Kidney from Deceased Donor: An Unusual Transplantation Utilizing Kidneys with Congenital Fusion Abnormality. Case Rep Transplant 2021; 2021:2286831. [PMID: 34422430 PMCID: PMC8373511 DOI: 10.1155/2021/2286831] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 06/28/2021] [Indexed: 02/05/2023] Open
Abstract
Transplanting horseshoe kidneys is challenging and has higher complication rates due to the unusual anatomy of the vascular and urinary collecting systems. Most centers avoid using these kidneys for transplantation. However, if chosen carefully, these organs can be used successfully to reduce organ shortage. In this paper, we will describe the technique of procurement of horseshoe kidneys from cadaveric donors, back table preparation, and its successful implantation in a recipient. With good planning and skillful surgical techniques, horseshoe kidneys can be successfully transplanted in suitable recipients. If properly selected, these kidneys can be used to reduce the organ scarcity and diminish waitlist morbidity and mortality.
Collapse
|
6
|
Brasil S, Bor-Seng-Shu E, de-Lima-Oliveira M, Taccone FS, Gattás G, Nunes DM, Gomes de Oliveira RA, Martins Tomazini B, Tierno PF, Becker RA, Bassi E, Sá Malbouisson LM, da Silva Paiva W, Teixeira MJ, de Carvalho Nogueira R. Computed tomography angiography accuracy in brain death diagnosis. J Neurosurg 2020; 133:1220-1228. [PMID: 31561215 DOI: 10.3171/2019.6.jns191107] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 06/18/2019] [Indexed: 01/22/2023]
Abstract
OBJECTIVE The present study was designed to answer several concerns disclosed by systematic reviews indicating no evidence to support the use of computed tomography angiography (CTA) in the diagnosis of brain death (BD). Therefore, the aim of this study was to assess the effectiveness of CTA for the diagnosis of BD and to define the optimal tomographic criteria of intracranial circulatory arrest. METHODS A unicenter, prospective, observational case-control study was undertaken. Comatose patients (Glasgow Coma Scale score ≤ 5), even those presenting with the first signs of BD, were included. CTA scanning of arterial and venous vasculature and transcranial Doppler (TCD) were performed. A neurological determination of BD and consequently determination of case (BD group) or control (no-BD group) was conducted. All personnel involved with assessing patients were blinded to further tests results. Accuracy of BD diagnosis determined by using CTA was calculated based on the criteria of bilateral absence of visualization of the internal cerebral veins and the distal middle cerebral arteries, the 4-point score (4PS), and an exclusive criterion of absence of deep brain venous drainage as indicated by the absence of deep venous opacification on CTA, the venous score (VS), which considers only the internal cerebral veins bilaterally. RESULTS A total of 106 patients were enrolled in this study; 52 patients did not have BD, and none of these patients had circulatory arrest observed by CTA or TCD (100% specificity). Of the 54 patients with a clinical diagnosis of BD, 33 met the 4PS (61.1% sensitivity), whereas 47 met the VS (87% sensitivity). The accuracy of CTA was time related, with greater accuracy when scanning was performed less than 12 hours prior to the neurological assessment, reaching 95.5% sensitivity with the VS. CONCLUSIONS CTA can reliably support a diagnosis of BD. The criterion of the absence of deep venous opacification, which can be assessed by use of the VS criteria investigated in this study, can confirm the occurrence of cerebral circulatory arrest.Clinical trial registration no.: 12500913400000068 (clinicaltrials.gov).
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Bruno Martins Tomazini
- 3Trauma Intensive Care Unit, Hospital das Clinicas, School of Medicine, São Paulo, Brazil; and
| | - Paulo Fernando Tierno
- 3Trauma Intensive Care Unit, Hospital das Clinicas, School of Medicine, São Paulo, Brazil; and
| | - Rafael Akira Becker
- 3Trauma Intensive Care Unit, Hospital das Clinicas, School of Medicine, São Paulo, Brazil; and
| | - Estevão Bassi
- 3Trauma Intensive Care Unit, Hospital das Clinicas, School of Medicine, São Paulo, Brazil; and
| | | | | | | | | |
Collapse
|
7
|
Whole Body CT Imaging in Deceased Donor Screening for Malignancies. Transplant Direct 2019; 5:e509. [PMID: 32095504 PMCID: PMC7004587 DOI: 10.1097/txd.0000000000000953] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Accepted: 09/29/2019] [Indexed: 01/04/2023] Open
Abstract
Background. In most western countries, the median donor age is increasing. The incidence of malignancies in older populations is increasing as well. To prevent donor-derived malignancies we evaluated radiologic donor screening in a retrospective donor cohort. Methods. This study analyzes the efficacy of a preoperative computed tomography (CT) scan on detecting malignancies. All deceased organ donors in the Netherlands between January 2013 and December 2017 were included. Donor reports were analyzed to identify malignancies detected before or during organ procurement. Findings between donor screening with or without CT-scan were compared. Results. Chest or abdominal CT-scans were performed in 17% and 18% of the 1644 reported donors respectively. Screening by chest CT-scan versus radiograph resulted in 1.5% and 0.0% detected thoracic malignancies respectively. During procurement no thoracic malignancies were found in patients screened by chest CT compared with 0.2% malignancies in the radiograph group. Screening by abdominal CT-scan resulted in 0.0% malignancies, compared with 0.2% in the abdominal ultrasound group. During procurement 1.0% and 1.3% malignancies were found in the abdominal CT-scan and ultrasound groups, respectively. Conclusions. Screening by CT-scan decreased the perioperative detection of tumors by 30%. A preoperative CT-scan may be helpful by providing additional information on (aberrant) anatomy to the procuring or transplanting surgeon. In conclusion, donor screening by CT-scan could decrease the risk of donor-derived malignancies and prevents unnecessary procurements per year in the Netherlands.
Collapse
|
8
|
Thuret R, Kleinclauss F, Terrier N, Timsit MO. [Deceased donation in renal transplantation]. Prog Urol 2016; 26:909-939. [PMID: 27727092 DOI: 10.1016/j.purol.2016.08.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 08/23/2016] [Indexed: 11/19/2022]
Abstract
OBJECTIVES To review epidemiologic data's and medical results of deceased donation in renal transplantation. MATERIAL AND METHODS Relevant publications were identified through Medline (http://www.ncbi.nlm.nih.gov) and Embase (http://www.embase.com) database using the following keywords, alone or in association, "brain death; cardiac arrest; deceased donation; organ procurement; transplantation". Articles were selected according to methods, language of publication and relevance. The reference lists were used to identify additional historical studies of interest. Both prospective and retrospective series, in French and English, as well as review articles and recommendations were selected. In addition, French national transplant and health agencies (http://www.agence-biomedecine.fr and http://www.has-sante.fr) databases were screened using identical keywords. A total of 2498 articles, 8 official reports and 17 newspaper articles were identified; after careful selection 157 publications were eligible for our review. RESULTS Deceased donation may involve either brain death or non-heartbeating donors (NHBD). Organ shortage led to the procurement of organs from expanded-criteria donors, with an increased age at donation and extended vascular disease, leading to inferior results after transplantation and underlining the need for careful donor management during brain death or cardiac arrest. Evolution of French legislation covering bioethics allowed procurement from Maastricht categories II and recently III non-heartbeating donors. CONCLUSION The increase of organ shortage emphasizes the need for a rigorous surgical technique during procurement to avoid loss of transplants. A history or current neoplasm in deceased-donors, requires attention to increase the pool of organs without putting the recipients at risk for cancer transmission. French NHBD program, especially from Maastricht category III, may stand for a potential source of valuable organs.
Collapse
Affiliation(s)
- R Thuret
- Service d'urologie et transplantation rénale, CHU de Montpellier, 34090 Montpellier, France; Université de Montpellier, 34090 Montpellier, France.
| | - F Kleinclauss
- Service d'urologie et transplantation rénale, CHRU de Besançon, 25030 Besançon, France; Université de Franche-Comté, 25030 Besançon, France; Inserm UMR 1098, 25030 Besançon, France
| | - N Terrier
- Service d'urologie et transplantation rénale, CHU de Grenoble, 38000 Grenoble, France
| | - M O Timsit
- Service d'urologie, hôpital européen Georges-Pompidou, AP-HP, 75015 Paris, France; Université Paris Descartes, 75006 Paris, France
| |
Collapse
|