1
|
Bedeschi MF, Baldassarri A, Villa R, Tanzi F, Salera S, Lombardo V, Draghi A, O'Sed NP, Casazza G, Vecchi M, Fraquelli M. Phenotypical Characterization of Gastroenterological and Metabolic Manifestations in Patients With Williams-Beuren Syndrome. Am J Med Genet A 2025; 197:e63993. [PMID: 39868851 DOI: 10.1002/ajmg.a.63993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 12/24/2024] [Accepted: 01/03/2025] [Indexed: 01/28/2025]
Abstract
Gastrointestinal (GI) symptoms are common in patients with Williams-Beuren syndrome (WBS), but their prevalence and possible causes are not yet fully known. This study assessed GI symptoms' prevalence and their possible origin by performing a predefined set of tests in adult WBS patients. Laboratory tests and a questionnaire were administered to assess GI symptoms and dietary habits. All the patients underwent the urea breath test, H2-lactose and H2-glucose breath tests, and intestinal ultrasound (IUS) and vibration-controlled transient elastography for liver stiffness measurement (LSM) and controlled attenuation parameter (CAP, dB/m). Thirty-one patients were enrolled (72% of the whole cohort, 17 males, median age 32 years). Gastroesophageal reflux disease (GERD) symptoms were reported in 29% of the patients, abdominal pain in 26%, and altered bowel habits in 48%. Pathologic signs at (IUS) were present in 60% of the cases. Prevalence was 0.26 (95% CI 0.12-0.44) for Helicobacter pylori infection and 0.61 (95% CI 0.42-0.78) for lactose intolerance. LSM was > 6 kPa (in the range of a fibrosis score > F1) in three patients, and CAP values were > 268 dB/m (corresponding to a steatosis score > S2, e.g., moderate steatosis) in nine. The presence of altered bowel habits was significantly related to chronic abdominal pain (OR 13.1, p = 0.03). Increased BMI (> 28 kg/m2) (OR 10.8, p = 0.04) was associated with the presence of moderate-severe hepatic steatosis. After specific treatment and dietary counseling, most patients reported resolution/improvement of symptoms, whereas a few retained/developed symptoms during follow-up. Chronic abdominal pain, GERD symptoms, and unbalanced metabolic parameters were common in our WBS patients, together with an increased prevalence of lactose intolerance/colonic diverticula. Specific counseling and treatment improved symptoms for most patients.
Collapse
Affiliation(s)
| | - Annarita Baldassarri
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Roberta Villa
- Clinical Genetics Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Federico Tanzi
- Department of Pathophysiology and Transplantation, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Simona Salera
- Direzione Medica di Presidio, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Vincenza Lombardo
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Alessandro Draghi
- Clinical Genetics Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Nicole Piazza O'Sed
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Giovanni Casazza
- Dipartimento di Scienze Cliniche e di Comunità, Università degli Studi di Milano, Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Maurizio Vecchi
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- Department of Pathophysiology and Transplantation, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Mirella Fraquelli
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
2
|
Qin J, Ma L, Zhou MY, Li WB, Xiao MS, Niu ZH, Yang H, Zhu QL. Determining the Accuracy and Interobserver Agreement of 4 Ultrasound Scores in Crohn's Disease Assessment: Correlations With Endoscopy. Clin Transl Gastroenterol 2025; 16:e00812. [PMID: 39791555 PMCID: PMC12020696 DOI: 10.14309/ctg.0000000000000812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Accepted: 12/20/2024] [Indexed: 01/12/2025] Open
Abstract
INTRODUCTION Gastrointestinal ultrasound (GIUS) is recommended for monitoring Crohn's disease (CD). GIUS scores are used to quantify CD activity. Among them, International Bowel Ultrasound Segmental Activity Score (IBUS-SAS), Bowel Ultrasound Score (BUSS), Simple Ultrasound Score, and Simple Ultrasound Score for Crohn's Disease are most commonly used. The aim of this study was to compare and correlate the performance of such indicators with endoscopic activity and to calculate interobserver agreement. METHODS Consecutive patients with CD at our hospital between June 2015 and July 2021 were retrospectively enrolled. All patients underwent ileocolonoscopy after medical treatment. GIUS was performed within 2 weeks, and 4 GIUS scores were independently calculated. Receiver operating characteristic curve analyses were used to determine a cutoff value. Cohen kappa (κ) coefficient was calculated to estimate the agreement between GIUS findings. RESULTS A total of 106 patients with CD were enrolled. 80.2% (85/106) were endoscopic active (Simple Endoscopic Score for Crohn's disease ≥3), and 8.49% (9/106) were severe cases (Simple Endoscopic Score for Crohn's disease ≥9). All GIUS features (bowel wall thickness, color Doppler signs, bowel wall stratification, inflammatory signals at the mesentery) were statistically significant in assessing CD activity ( P < 0.05). IBUS-SAS showed the highest area under the curve (0.98; 95% CI: 0.96-1.00) and specificity (95.2%) for a cutoff value of 46.50. However, IBUS-SAS had only moderate agreement (Cohen κ = 0.427; P < 0.001). BUSS had substantial interobserver agreement (Cohen κ = 0.947; P < 0.001), with a similar diagnostic value (sensitivity, 100.0%; accuracy, 95.3%; area under the curve of 0.96 [95% CI: 0.91-1.00] for a cutoff value of 4.58). DISCUSSION GIUS score is an efficient and reliable method to assess CD activity. BUSS achieved a high accuracy and excellent interobserver agreement, which is more suitable for treatment assessment.
Collapse
Affiliation(s)
- Jing Qin
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Li Ma
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Meng-Yuan Zhou
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wen-Bo Li
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Meng-Su Xiao
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zi-Han Niu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hong Yang
- Department of Gastroenterology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Qing-Li Zhu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
3
|
Bove L, Meyer J, Collins M, Frampas E, Bourreille A, Le Berre C. Understanding the learning curve of intestinal ultrasound in inflammatory bowel disease: A comparative study between novice, regular and expert. Clin Res Hepatol Gastroenterol 2025; 49:102548. [PMID: 39933651 DOI: 10.1016/j.clinre.2025.102548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2024] [Revised: 01/30/2025] [Accepted: 02/03/2025] [Indexed: 02/13/2025]
Abstract
BACKGROUND Intestinal ultrasound (IUS) has emerged as a valuable tool for monitoring inflammatory bowel disease (IBD), but its reliability depends on the technical skills of the operator. AIMS This study aimed to assess the IUS learning curve of a novice briefly trained to get him familiarized with the ultrasound machine and normal/abnormal IUS images, and a gastroenterologist with formal general ultrasound training and regular IUS experience (> 200 exams), using an expert radiologist as the gold standard. METHODS The ULTRA-IBD study was a single-center, prospective study involving 50 consecutive IBD patients. Three successive IUS examinations were performed on each patient by the 3 operators. Inter-rater agreement on IUS disease activity was calculated using the intraclass correlation coefficient. RESULTS The experienced gastroenterologist demonstrated consistently good agreement with the radiologist throughout the study, while the novice failed to go beyond poor agreement after 50 examinations, although a faster learning curve was observed in patients without history of IBD surgery. CONCLUSION These findings highlight the difficulty of the technical performance of IUS rather than its interpretation. Comprehensive ultrasound training beforehand and between 50 and 200 examinations of experience are necessary before embarking on IUS.
Collapse
Affiliation(s)
- Léo Bove
- Institut des Maladies de l'Appareil Digestif (IMAD), Hépato-Gastro-Entérologie et Assistance Nutritionnelle, Inserm CIC 1413, Nantes Université, CHU Nantes, F-44000 Nantes, France.
| | - Jérémy Meyer
- Central Department of Radiology and Medical Imaging, Nantes Université, CHU Nantes, F-44000 Nantes, Nantes, France.
| | - Michael Collins
- Institut des Maladies de l'Appareil Digestif (IMAD), Hépato-Gastro-Entérologie et Assistance Nutritionnelle, Inserm CIC 1413, Nantes Université, CHU Nantes, F-44000 Nantes, France.
| | - Eric Frampas
- Central Department of Radiology and Medical Imaging, Nantes Université, CHU Nantes, F-44000 Nantes, Nantes, France.
| | - Arnaud Bourreille
- Institut des Maladies de l'Appareil Digestif (IMAD), Hépato-Gastro-Entérologie et Assistance Nutritionnelle, Inserm CIC 1413, Nantes Université, CHU Nantes, F-44000 Nantes, France; Institut des Maladies de l'Appareil Digestif (IMAD), Inserm UMR 1235, Nantes Université, CHU Nantes, F-44000 Nantes, France.
| | - Catherine Le Berre
- Institut des Maladies de l'Appareil Digestif (IMAD), Hépato-Gastro-Entérologie et Assistance Nutritionnelle, Inserm CIC 1413, Nantes Université, CHU Nantes, F-44000 Nantes, France; Institut des Maladies de l'Appareil Digestif (IMAD), Inserm UMR 1235, Nantes Université, CHU Nantes, F-44000 Nantes, France.
| |
Collapse
|
4
|
Kumar R, Melmed GY, Gu P. Imaging in Inflammatory Bowel Disease. Rheum Dis Clin North Am 2024; 50:721-733. [PMID: 39415376 DOI: 10.1016/j.rdc.2024.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2024]
Abstract
The incidence of inflammatory bowel disease (IBD) is rising globally. We need more tools and techniques in our armamentarium for early diagnosis, tight monitoring, and to assess disease complications of IBD. This article reviews the role of cross-sectional imaging, mainly computed tomography, MRI, and intestinal ultrasound (IUS) in IBD and its advantages, disadvantages, and limitations. While popular in other parts of the world, IUS is underutilized in the United States. It is safe, accurate, can be repeated multiple times and provides quick and actionable results in IBD care without the risk of radiation and contrast.
Collapse
Affiliation(s)
- Rashmi Kumar
- Department of Gastroenterology, Margolis Family Inflammatory Bowel Disease Program, Hoag Digestive Health Institute, Hoag Hospital, Newport Beach, CA, USA.
| | - Gil Y Melmed
- F Widjaja Inflammatory Bowel Disease Institute, Karsh Division of Gastroenterology and Hepatology, Department of Medicine, Cedars-Sinai, 8730 Alden Drive, 239E, Los Angeles, CA 90048, USA
| | - Phillip Gu
- F Widjaja Inflammatory Bowel Disease Institute, Karsh Division of Gastroenterology and Hepatology, Department of Medicine, Cedars-Sinai, 8730 Alden Drive, Suite E240A, Los Angeles, CA 90048, USA. https://twitter.com/DrPhil_Gu
| |
Collapse
|
5
|
Mohamed EMAA, Eskander AE, Mahmoud RO, Ali HMSE. Combined gray scale ultrasonography and doppler diagnostic tools with strain elastography in assessment of inflammatory bowel disease in pediatrics patients. J Ultrasound 2024; 27:537-544. [PMID: 38483770 PMCID: PMC11333772 DOI: 10.1007/s40477-024-00870-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 01/05/2024] [Indexed: 08/21/2024] Open
Abstract
BACKGROUND Intestinal changes in inflammatory bowel disease (IBD) are frequently observed on ultrasound. Invasive diagnostic procedures are often employed to differentiate between the main types of IBD and detect complications. Ultrasound Strain Elastography (SE) is a promising non-invasive technique for detecting intestinal changes and assessing inflammatory activity in pediatric IBD. AIM OF THE STUDY This research aims to evaluate the diagnostic performance of conventional ultrasound, color Doppler, and SE in assessing inflammatory bowel disease in pediatric patients, both separately and in combination as additional tools. PATIENTS AND METHODS Forty patients (18 females and 22 males) initially diagnosed with IBD through clinical and endoscopic biopsy, along with 20 healthy controls, underwent conventional ultrasound, color Doppler, SE, and laboratory evaluations, including CBC, ESR, CRP, Fecal calprotectin, and assessment of IBD activity using PIBDAI. RESULTS Conventional ultrasound, color Doppler, and SE significantly contributed to detecting disease activity and intestinal changes in IBD (p < 0.001; 95% CI 0.79-1.100), demonstrating better sensitivity in combination compared to each method individually. The combined approach showed 100% sensitivity, 84% specificity, 78.6% precision (Positive Predictive Value), 100% Negative Predictive Value, and an overall accuracy of 92%. CONCLUSION The addition of Color Doppler and SE parameters to grayscale ultrasound provides diagnostic value comparable to endoscopy, histopathology, and laboratory markers in detecting inflammatory activity and intestinal changes in IBD. This combined approach can help avoid unnecessary invasive techniques for follow-up.
Collapse
|
6
|
Pruijt MJ, de Voogd FAE, Montazeri NSM, van Etten-Jamaludin FS, D’Haens GR, Gecse KB. Diagnostic Accuracy of Intestinal Ultrasound in the Detection of Intra-Abdominal Complications in Crohn's Disease: A Systematic Review and Meta-Analysis. J Crohns Colitis 2024; 18:958-972. [PMID: 38173288 PMCID: PMC11147796 DOI: 10.1093/ecco-jcc/jjad215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 10/28/2023] [Indexed: 01/05/2024]
Abstract
BACKGROUND Crohn's disease [CD] is frequently associated with the development of strictures and penetrating complications. Intestinal ultrasound [IUS] is a non-invasive imaging modality ideal for point-of-care assessment. In this systematic review and meta-analysis we provide a current overview on the diagnostic accuracy of IUS and its advanced modalities in the detection of intra-abdominal complications in CD compared to endoscopy, cross-sectional imaging, surgery, and pathology. METHOD We conducted a literature search for studies describing the diagnostic accuracy of IUS in adult patients with CD-related intra-abdominal complications. Quality of the included studies was assessed with the QUADAS-2 tool. Meta-analysis was performed for both conventional IUS [B-mode] and oral contrast IUS [SICUS]. RESULTS Of the 1498 studies we identified, 68 were included in this review and 23 studies [3863 patients] were used for the meta-analysis. Pooled sensitivities and specificities for strictures, inflammatory masses, and fistulas by B-mode IUS were 0.81 and 0.90, 0.87 [sensitivities] and 0.95, and 0.67 and 0.97 [specificities], respectively. Pooled overall log diagnostic odds ratios were 3.56, 3.97 and 3.84, respectively. Pooled sensitivity and specificity of SICUS were 0.94 and 0.95, 0.91 and 0.97 [sensitivities], and 0.90 and 0.94 [specificities], respectively. The pooled overall log diagnostic odds ratios of SICUS were 4.51, 5.46, and 4.80, respectively. CONCLUSION IUS is accurate for the diagnosis of intra-abdominal complications in CD. As a non-invasive, point-of-care modality, IUS is recommended as the first-line imaging tool if there is a suspicion of CD-related intra-abdominal complications.
Collapse
Affiliation(s)
- Maarten J Pruijt
- Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | - Floris A E de Voogd
- Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | - Nahid S M Montazeri
- Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | | | - Geert R D’Haens
- Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | - Krisztina B Gecse
- Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands
| |
Collapse
|
7
|
Lu C, Rosentreter R, Delisle M, White M, Parker CE, Premji Z, Wilson SR, Baker ME, Bhatnagar G, Begun J, Bruining DH, Bryant R, Christensen B, Feagan BG, Fletcher JG, Jairath V, Knudsen J, Kucharzik T, Maaser C, Maconi G, Novak K, Rimola J, Taylor SA, Wilkens R, Rieder F. Systematic review: Defining, diagnosing and monitoring small bowel strictures in Crohn's disease on intestinal ultrasound. Aliment Pharmacol Ther 2024; 59:928-940. [PMID: 38436124 DOI: 10.1111/apt.17918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 12/29/2023] [Accepted: 02/11/2024] [Indexed: 03/05/2024]
Abstract
BACKGROUND Stricturing Crohn's disease (CD) occurs most commonly in the terminal ileum and poses a clinical problem. Cross-sectional imaging modalities such as intestinal ultrasound (IUS), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) allow for assessment of the entire bowel wall and associated peri-enteric findings. Radiologic definitions of strictures have been developed for CTE and MRE; their reliability and responsiveness are being evaluated in index development programs. A comprehensive assessment strategy for strictures using IUS is needed. AIMS To provide a detailed summary of definitions, diagnosis and monitoring of strictures on IUS as well as technical aspects of image acquisition. METHODS We searched four databases up to 6 January 2024. Two-stage screening was done in duplicate. We assessed risk of bias using QUADAS-2. RESULTS There were 56 studies eligible for inclusion. Definitions for strictures on IUS are heterogeneous, but the overall accuracy for diagnosis of strictures is high. The capability of IUS for characterising inflammation versus fibrosis in strictures is not accurate enough to be used in clinical practice or trials. We summarise definitions for improvement of strictures on IUS, and discuss parameters for image acquisition and standardisation. CONCLUSIONS This systematic review is the first step for a structured program to develop a stricture IUS index for CD.
Collapse
Affiliation(s)
- Cathy Lu
- Division of Gastroenterology and Hepatology, University of Calgary, Calgary, Alberta, Canada
| | - Ryan Rosentreter
- Division of Gastroenterology and Hepatology, University of Calgary, Calgary, Alberta, Canada
| | - Maxime Delisle
- Department of Medicine, Division of Gastroenterology, Université de Sherbrooke, Sherbrooke, Quebec, Canada
| | - Mattie White
- Department of Gastroenterology, Hepatology & Nutrition; Digestive Diseases and Surgery Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
| | | | - Zahra Premji
- Libraries, University of Victoria, Victoria, British Columbia, Canada
| | - Stephanie R Wilson
- Division of Gastroenterology and Hepatology, University of Calgary, Calgary, Alberta, Canada
- Department of Radiology, University of Calgary, Calgary, Alberta, Canada
| | - Mark E Baker
- Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Gauraang Bhatnagar
- Centre for Medical Imaging, University College London, London, UK
- Frimley Health NHS Foundation Trust, Surrey, UK
| | - Jakob Begun
- Department of Gastroenterology, Mater Hospital, Brisbane, Queensland, Australia
| | - David H Bruining
- Department of Gastroenterology, Queen Elizabeth Hospital, Adelaide, South Australia
| | - Robert Bryant
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Britt Christensen
- Department of Gastroenterology, Royal Melbourne Hospital and University of Melbourne, Melbourne, Victoria, Australia
| | - Brian G Feagan
- Alimentiv Inc., London, Ontario, Canada
- Department of Medicine, University of Western Ontario, London, Ontario, Canada
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Vipul Jairath
- Alimentiv Inc., London, Ontario, Canada
- Department of Medicine, University of Western Ontario, London, Ontario, Canada
- Department of Epidemiology and Biostatistics, Department of Medicine, Western University, London, Ontario, Canada
| | - John Knudsen
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Torsten Kucharzik
- Department of General Internal Medicine and Gastroenterology, University Teaching Hospital Lüneburg, Lüneburg, Germany
| | - Christian Maaser
- Outpatients' Department of Gastroenterology, University Teaching Hospital Lüneburg, Lüneberg, Germany
| | - Giovanni Maconi
- Gastroenterology Unit, Department of Biomedical and Clinical Sciences, University of Milan, Milan, Italy
| | - Kerri Novak
- Division of Gastroenterology and Hepatology, University of Calgary, Calgary, Alberta, Canada
| | - Jordi Rimola
- IBD Unit, Radiology Department, Hospital Clinic Barcelona, IDIBAPS, Barcelona, Spain
| | - Stuart A Taylor
- Centre for Medical Imaging, University College London, London, UK
| | - Rune Wilkens
- Digestive Disease Center, Copenhagen University Hospital-Bispebjerg, Copenhagen, Denmark
- Copenhagen Intestinal Ultrasound, Bispebjerg Hospital, Copenhagen, Denmark
| | - Florian Rieder
- Department of Gastroenterology, Hepatology & Nutrition; Digestive Diseases and Surgery Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA
- Cleveland Clinic Center for Global Translational Inflammatory Bowel Diseases, Cleveland, Ohio, USA
- Department of Inflammation and Immunity, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
8
|
Kumar S, Parry T, Mallett S, Plumb A, Bhatnagar G, Beable R, Betts M, Duncan G, Gupta A, Higginson A, Hyland R, Lapham R, Patel U, Pilcher J, Slater A, Tolan D, Zealley I, Halligan S, Taylor SA. Diagnostic performance of sonographic activity scores for adult terminal ileal Crohn's disease compared to magnetic resonance and histological reference standards: experience from the METRIC trial. Eur Radiol 2024; 34:455-464. [PMID: 37526665 PMCID: PMC10791915 DOI: 10.1007/s00330-023-09958-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
OBJECTIVES The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.
Collapse
Affiliation(s)
- Shankar Kumar
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK
| | - Thomas Parry
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK
| | - Sue Mallett
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK
| | - Andrew Plumb
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK
| | - Gauraang Bhatnagar
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK
- Department of Radiology, Frimley Park Hospital, Surrey, UK
| | - Richard Beable
- Department of Radiology, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Margaret Betts
- Department of Radiology, Ninewells Hospital and Medical School, Dundee, UK
| | - Gillian Duncan
- Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Arun Gupta
- Department of Radiology, St Mark's Hospital, London North West University Healthcare NHS Trust, London, UK
| | - Antony Higginson
- Department of Radiology, Queen Alexandra Hospital, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Rachel Hyland
- Department of Radiology, St James' University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Roger Lapham
- Department of Radiology, St James' University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Uday Patel
- Department of Radiology, St Mark's Hospital, London North West University Healthcare NHS Trust, London, UK
| | - James Pilcher
- Department of Radiology, St George's University Hospitals NHS Foundation Trust, London, UK
| | - Andrew Slater
- Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Damian Tolan
- Department of Radiology, St James' University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Ian Zealley
- Department of Radiology, Ninewells Hospital and Medical School, Dundee, UK
| | - Steve Halligan
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK
| | - Stuart A Taylor
- Centre for Medical Imaging, University College London (UCL), 2nd Floor Charles Bell House, 43-45 Foley Street, W1W 7TS, London, UK.
| |
Collapse
|
9
|
Nishida M, Hasegawa Y, Hata J. Basic practices for gastrointestinal ultrasound. J Med Ultrason (2001) 2023; 50:285-310. [PMID: 36087155 PMCID: PMC10354189 DOI: 10.1007/s10396-022-01236-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Accepted: 06/07/2022] [Indexed: 11/28/2022]
Abstract
The standard diagnostic modalities for gastrointestinal (GI) diseases have long been endoscopy and barium enema. Recently, trans-sectional imaging modalities, such as computed tomography and magnetic resonance imaging, have become increasingly utilized in daily practice. In transabdominal ultrasonography (US), the bowel sometimes interferes with the observation of abdominal organs. Additionally, the thin intestinal walls and internal gas can make structures difficult to identify. However, under optimal US equipment settings, with identification of the sonoanatomy and knowledge of the US findings of GI diseases, US can be used effectively to diagnose GI disorders. Thus, the efficacy of GIUS has been gradually recognized, and GIUS guidelines have been published by the World Federation for Ultrasound in Medicine and Biology and the European Federation of Societies for Ultrasound in Medicine and Biology. Following a systematic scanning method according to the sonoanatomy and precisely estimating the layered wall structures by employing color Doppler make diagnosing disease and evaluating the degree of inflammation possible. This review describes current GIUS practices from an equipment perspective, a procedure for systematic scanning, typical findings of the normal GI tract, and 10 diagnostic items in an attempt to help medical practitioners effectively perform GIUS and promote the use of GIUS globally.
Collapse
Affiliation(s)
- Mutsumi Nishida
- Diagnostic Center for Sonography, Hokkaido University Hospital, N14 W5, Kita-ku, Sapporo, 060-8648, Japan.
| | - Yuichi Hasegawa
- Department of Clinical Laboratory, Japanese Red Cross Narita Hospital, Narita, Japan
| | - Jiro Hata
- Department of Laboratory Medicine (Endoscopy and Ultrasound), Kawasaki Medical School Hospital, Okayama, Japan
| |
Collapse
|
10
|
Jannatdoust P, Valizadeh P, Razaghi M, Rouzbahani M, Abbasi A, Arian A. Role of abbreviated non-contrast-enhanced MR-enterography in the evaluation of Crohn's disease activity and complications as an alternative for full protocol contrast-enhanced study: A systematic review and meta-analysis. RESEARCH IN DIAGNOSTIC AND INTERVENTIONAL IMAGING 2023; 6:100030. [PMID: 39077544 PMCID: PMC11265495 DOI: 10.1016/j.redii.2023.100030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 04/24/2023] [Indexed: 07/31/2024]
Abstract
Background Crohn's disease (CD) is a chronic disorder that often starts at a young age and involves periods of remission and relapse. Prompt diagnosis of relapses through screening is crucial due to the potential morbid complications of untreated active inflammation. Magnetic resonance enterography (MRE) is a noninvasive technique to screen for active inflammation. The standard protocol involves intravenous injection of contrast agents with potential side effects. Some abbreviated non-contrast-enhanced MRE protocols are proposed as alternatives for conventional MRE to identify active inflammation. Currently, there is controversy regarding the applicability and accuracy of these protocols. This study aims to describe and compare these protocols and evaluate their accuracy in detecting active inflammation and CD complications. Methods Results from a systematic search of three databases in August 2022 were queried and screened by abstract and full text. Eligible studies were qualitatively and quantitatively analyzed by diagnostic test accuracy meta-analysis. Results 59 studies entered the systematic review, and 37 were eligible for meta-analysis. Diffusion-weighted imaging (DWI) and fast T2-weighted (T2w) sequences were most frequently used in abbreviated protocols and showed non-inferior accuracy compared to the full protocol in detecting active inflammation. ADC and qualitative DWI had pooled sensitivity of 90% (CI: 82-95%) and 89% (CI:82-93%) and pooled specificity of 94% (CI: 88-97%) and 89% (CI: 79-94%), respectively for detecting active inflammation. Moreover, T2w and combined T2w+DWI sequences had pooled sensitivity of 80% (CI: 64-90%) and 76% (CI: 61-86%) and pooled specificity of 90% (CI: 80-95%) and 87% (CI: 74 - 94%), respectively. Unenhanced protocols show relatively poor diagnostic accuracy in detecting penetrating complications of CD. Magnetization transfer imaging (MTI) has demonstrated excellent accuracy in detecting fibrosis. High heterogeneity was observed in all subgroups, and accuracy was reported to be highly operator dependent in most studies. Conclusion An abbreviated protocol consisting of DWI and fast T2w imaging can potentially replace the full protocol MRE. Full protocol MRE will still have its role in identifying penetrating complications. MTI should be indicated in case of suspected fibrostenotic disease.
Collapse
Affiliation(s)
- Payam Jannatdoust
- School of Medicine, Tehran University of Medical Science, Tehran, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Parya Valizadeh
- School of Medicine, Tehran University of Medical Science, Tehran, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahshad Razaghi
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Maedeh Rouzbahani
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Amirbahador Abbasi
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Arvin Arian
- School of Medicine, Tehran University of Medical Science, Tehran, Iran
- Advanced Diagnostic and Interventional Radiologic Research Center (ADIR), Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
11
|
Xia Q, Li M, Xu M, Chen S, Xie X, Chen Y. Measurement of the stiffness of the normal terminal ileum mesentery using shear-wave elastography. Eur J Radiol 2023; 163:110807. [PMID: 37030100 DOI: 10.1016/j.ejrad.2023.110807] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 03/31/2023]
Abstract
OBJECTIVE To investigate the feasibility of using shear-wave elastography (SWE) to measure the stiffness of the normal terminal ileum mesentery, and to establish its normal reference range. METHODS Ninety-five normal subjects and 22 patients with mesentery-related disease were included. The average Young's modulus of the normal terminal ileal mesentery was measured by SWE ultrasound. The thickness and the extent to which mesenteric fat extended around the intestinal circumference of the normal terminal ileum were also recorded. The normal reference range was established and the SWE values of normal and diseased subjects were compared. RESULTS Transabdominal SWE examination of the terminal ileum mesentery was successfully performed on 91 subjects (95.8 %). The mean extent range, thickness, and SWE value of the normal terminal ileum mesentery were 1/4 (1/5-1/3), 6.8 ± 2.4 mm, and 4.3 ± 2.1 kPa, respectively. These parameters did not differ significantly between genders, and across age and body mass index groups (all P > 0.05). The intra- and inter-operator consistencies were excellent for the replicated SWE measurements (0.801 [95 % confidence interval: 0.560-0.916] and 0.751 (95 % confidence interval: 0.388-0.900], respectively). The mean mesenteric elasticity in diseased subjects was 21.9 ± 10.7 kPa, which was significantly higher than that in normal subjects (P < 0.001). The cut-off value for mesenteric elasticity was 9.3 kPa, with a sensitivity of 90 % and a specificity of 100 % (P < 0.001). CONCLUSION SWE can be used to reliably evaluate the stiffness of the terminal ileum mesentery in normal subjects.
Collapse
Affiliation(s)
- Qingqing Xia
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Manying Li
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Ming Xu
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Shuling Chen
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Xiaoyan Xie
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Yujun Chen
- Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
12
|
Sakurai K, Katsurada T, Nishida M, Omotehara S, Fukushima S, Otagiri S, Nagashima K, Onishi R, Takagi R, Komatsu Y, Sakamoto N. Characteristics and usefulness of transabdominal ultrasonography in immune-mediated colitis. Intest Res 2023; 21:126-136. [PMID: 35860848 PMCID: PMC9911272 DOI: 10.5217/ir.2021.00166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 06/06/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND/AIMS The usefulness of ultrasonography (US) in diseases of the gastrointestinal tract has been reported recently. This prospective study aimed to determine the features of US findings in immune-mediated colitis (IMC), an adverse event induced by immune checkpoint inhibitor, and examine the correlation between US findings, colonoscopy (CS) findings, and severity of colitis. METHODS We studied patients examined using CS and US upon suspicion of IMC in Hokkaido University Hospital between April 2018 and February 2021. Endoscopic findings of IMC were assessed using the Ulcerative Colitis Endoscopic Index of Severity (UCEIS). The severity of US findings in IMC was evaluated using US grade, which is the ultrasonographic grading scale in ulcerative colitis. Bowel wall thickness and the intensity of the color Doppler signal were also analyzed. Severity of colitis was evaluated using Common Terminology Criteria for Adverse Events (CTCAE) grade version 5. RESULTS Fourteen patients with IMC were enrolled. The US findings were bowel wall thickening, loss of stratification, ulceration and increased blood flow signal. The US grade was moderately correlated with the UCEIS (r=0.687, p=0.009) and CTCAE grade (r=0.628, p=0.035). Bowel wall thickness and UCEIS (r=0.628, p=0.020), as well as color Doppler signal grade and CTCAE grade (r=0.724, p=0.008), were significantly correlated. CONCLUSIONS US findings in IMC were mainly similar to those of ulcerative colitis, but there were some findings that were characteristic only of IMC. Significant correlation was found between US findings, CS findings, and severity of colitis. Hence, US could be useful for the evaluation of IMC.
Collapse
Affiliation(s)
- Kensuke Sakurai
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Takehiko Katsurada
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan,Correspondence to Takehiko Katsurada, Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Kita-15, Nishi-7 Kita-ku, Sapporo 060-8638, Japan. Tel: +81-11-716-1161, Fax: +81-11-706-7999, E-mail:
| | - Mutsumi Nishida
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Sapporo, Japan,Diagnostic Center for Sonography, Hokkaido University Hospital, Sapporo, Japan
| | - Satomi Omotehara
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Sapporo, Japan,Diagnostic Center for Sonography, Hokkaido University Hospital, Sapporo, Japan
| | - Shinya Fukushima
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Shinsuke Otagiri
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Kazunori Nagashima
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Reizo Onishi
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Ryo Takagi
- Clinical Research and Medical Innovation Center, Hokkaido University Hospital, Sapporo, Japan
| | - Yoshito Komatsu
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan,Depatment of Cancer Chemotherapy, Hokkaido University Hospital Cancer Center, Sapporo, Japan
| | - Naoya Sakamoto
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| |
Collapse
|
13
|
Al-Ani AH, Vaughan R, Christensen B, Bryant RV, Novak KL. Treat to transmural healing: how to incorporate intestinal ultrasound into the treatment of inflammatory bowel disease. Br J Radiol 2022; 95:20211174. [PMID: 35766939 PMCID: PMC10996947 DOI: 10.1259/bjr.20211174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Intestinal ultrasound (IUS) is emerging as a key tool to achieving the therapeutic target of transmural healing in inflammatory bowel disease (IBD). IUS is a non-invasive, radiation-free, imaging modality comparable to MRI, CT and ileocolonoscopy (IC). With the appropriate training and equipment, IUS can be an easily repeatable bedside test for IBD diagnosis and disease monitoring, including treatment response. Core to successful high quality IUS employment are appropriate training and expert techniques; however, the training pathway will not be explored in this review. Given the increasing shift towards objective assessment for tight disease control, gastroenterologist-led IUS should be incorporated into the armamentarium of imaging modalities alongside radiologists, to enhance our diagnostic and monitoring toolbox. This comprehensive review aims to outline the current literature around IUS and propose the placement of IUS in a treat-to-target algorithm in IBD. Ultimately, IUS facilitates timely management decisions to optimise patient care with potential to revolutionise patient outcomes, moving towards transmural healing as the holy grail of therapy in IBD.
Collapse
Affiliation(s)
- Aysha H Al-Ani
- Department of Medicine, University of Melbourne, Melbourne, Australia
- Department of Gastroenterology, The Royal Melbourne Hospital, Melbourne, Australia
| | - Rose Vaughan
- Department of Medicine, University of Melbourne, Melbourne, Australia
- Department of Gastroenterology, The Royal Melbourne Hospital, Melbourne, Australia
| | - Britt Christensen
- Department of Medicine, University of Melbourne, Melbourne, Australia
- Department of Gastroenterology, The Royal Melbourne Hospital, Melbourne, Australia
| | - Robert V Bryant
- Department of Gastroenterology, The Queen Elizabeth Hospital, Woodville, Australia
- School of Medicine, University of Adelaide, Adelaide, Australia
| | - Kerri L Novak
- Department of Gastroenterology, The University of Calgary, Alberta, Australia
| |
Collapse
|
14
|
Vaughan R, Tjandra D, Patwardhan A, Mingos N, Gibson R, Boussioutas A, Ardalan Z, Al‐Ani A, Gibson PR, Christensen B. Toward transmural healing: Sonographic healing is associated with improved long-term outcomes in patients with Crohn's disease. Aliment Pharmacol Ther 2022; 56:84-94. [PMID: 35343603 PMCID: PMC9313877 DOI: 10.1111/apt.16892] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 02/09/2022] [Accepted: 03/04/2022] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND AIMS Transmural healing has emerged as a treatment target in Crohn's disease (CD). We investigated whether transmural healing assessed with intestinal ultrasound (IUS) is associated with improved clinical outcomes in patients with CD in clinical remission. METHODS Patients with CD in clinical remission at baseline (HBI <4) having IUS between August 2017 and June 2020 with at least 6-months' follow-up were retrospectively studied. Time to medication escalation, corticosteroid use and CD-related hospitalisation or surgery were compared by the presence or absence of sonographic healing, defined as bowel wall thickness ≤3 mm without hyperemia on color Doppler, inflammatory fat, or disrupted bowel wall stratification. Factors associated with survival were analyzed by Kaplan-Meier analysis using Cox proportional-hazard model. RESULTS Of 202 consecutive patients (50% male), sonographic inflammation was present in 61%. During median follow-up of 19 (IQR 13-27) months, medication escalation occurred in 52%, corticosteroid use in 23%, hospitalisation in 21%, and CD-related surgery in 13%. Sonographic healing was significantly associated with a reduced risk of medication escalation (p = 0.0018), corticosteroid use (p = 0.0247), hospitalisation (p = 0.0102), and surgery (p = 0.083). On multivariable analysis, sonographic healing was significantly associated with an increased odds of medication escalation-free survival (hazard ratio [HR]:1.94; 95% CI 1.23-3.06; p = 0.004) and corticosteroid-free survival (HR:2.41; 95% CI 1.24-4.67; p = 0.009), but not with hospitalisation or surgery. CONCLUSION In patients with CD in clinical remission, sonographic healing is associated with improved clinical outcomes. Further studies are needed to determine whether sonographic healing should be a treatment target.
Collapse
Affiliation(s)
- Rose Vaughan
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Douglas Tjandra
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Ashwin Patwardhan
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Nicholas Mingos
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Robert Gibson
- Department of RadiologyRoyal Melbourne HospitalMelbourneAustralia
| | - Alex Boussioutas
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Zaid Ardalan
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Aysha Al‐Ani
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| | - Peter R. Gibson
- Department of GastroenterologyAlfred Hospital and Monash UniversityMelbourneAustralia
| | - Britt Christensen
- Department of GastroenterologyRoyal Melbourne HospitalMelbourneAustralia
| |
Collapse
|
15
|
Hata J, Imamura H. The Use of Transabdominal Ultrasound in Inflammatory Bowel Disease. Korean J Radiol 2022; 23:308-321. [PMID: 35213095 PMCID: PMC8876649 DOI: 10.3348/kjr.2021.0692] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 11/11/2021] [Accepted: 12/20/2021] [Indexed: 11/18/2022] Open
Abstract
Transabdominal ultrasound (TAUS) is useful in all aspects of lesion screening, monitoring activity, or treating/diagnosing any related complications of inflammatory bowel disease. Its ability to screen or diagnose complications is almost the same as that of other methods, such as CT or MRI. Moreover, its noninvasiveness makes it a first-line examination method. A TAUS image depicting ulcerative colitis will show large intestinal wall thickening that is continuous from the rectum, which is mainly due to mucosal layer thickening, while for Crohn’s disease, a TAUS image is characterized by a diversity in the areas affected, distribution, and layer structure. Indicators of activity monitoring include wall thickness, wall structure, and vascular tests that use Doppler ultrasound or contrast agents. While all of these have been reported to be useful, at this time, no single parameter has been established as superior to others; therefore, a comprehensive evaluation of these parameters is justified. In addition, evaluating the elasticity of lesions using elastography is particularly useful for distinguishing between fibrous and inflammatory stenoses. However, the lack of objectivity is the biggest drawback of using ultrasound. Standardizing and popularizing the ultrasound process will be necessary, including scanning methods, equipment settings, and image analysis.
Collapse
Affiliation(s)
- Jiro Hata
- Division of Endoscopy and Ultrasound, Department of Clinical Pathology and Laboratory Medicine, Kawasaki Medical School, Okayama, Japan.
| | - Hiroshi Imamura
- Division of Endoscopy and Ultrasound, Department of Clinical Pathology and Laboratory Medicine, Kawasaki Medical School, Okayama, Japan
| |
Collapse
|
16
|
Helwig U, Fischer I, Hammer L, Kolterer S, Rath S, Maaser C, Kucharzik T. Transmural Response and Transmural Healing Defined by Intestinal Ultrasound: New Potential Therapeutic Targets? J Crohns Colitis 2022; 16:57-67. [PMID: 34185843 DOI: 10.1093/ecco-jcc/jjab106] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND AND AIMS Intestinal ultrasound [IUS] is a useful modality to monitor patients with inflammatory bowel disease [IBD]. Little is known about the use of IUS and appropriate definitions for transmural response [TR] and healing [TH]. We aimed to establish the use of IUS in monitoring TH as a potential target in routine medical practice. METHODS Based on the prospective, non-interventional, multicentre studies TRUST and TRUST&UC, we conducted a post-hoc analysis of 351 IBD patients with increased bowel wall thickness [BWT]. We analysed the rates of patients achieving TR and TH, comparing three definitions of TH. In 137 Crohn's disease [CD] patients, the predictive value of TR and TH was investigated for the clinical and sonographic outcome at week 52. RESULTS Within 12 weeks of treatment intensification, 65.6% [n = 118] of CD patients and 76.6% [n = 131] of ulcerative colitis [UC] patients showed a TR. Depending on the definition, 23.9-37.2% [n = 58/67/43] of CD patients and 45.0-61.4% [n = 90/105/77] of UC patients had TH at week 12. CD patients with TH were more likely to reach clinical remission at week 12 (odds ratio [OR] 3.33 [1.09-10.2]; p = 0.044) and a favourable sonographic outcome (OR 5.59 [1.97-15.8]; p = 0.001) at week 52 compared with patients without TH. CONCLUSIONS IUS response and TH in a relevant proportion of patients suggests that IUS is a useful method to assess transmural inflammatory activity in daily clinical practice. TR and TH are predictive for the sonographic outcome at week 52.
Collapse
Affiliation(s)
- Ulf Helwig
- University Hospital of Kiel, 1st Medical Department, Arnold Heller Str. 9, 24105 Kiel, Germany.,Private Practice for Internal Medicine, Department of Gastroenterology, Neue Donnerschweer Str. 30, 26123 Oldenburg, Germany
| | | | - Leonie Hammer
- Medical Department, AbbVie Deutschland GmbH and Co KG, Wiesbaden, Hesse, Germany
| | - Stefanie Kolterer
- Medical Department, AbbVie Deutschland GmbH and Co KG, Wiesbaden, Hesse, Germany
| | - Stefan Rath
- Medical Department, AbbVie Deutschland GmbH and Co KG, Wiesbaden, Hesse, Germany
| | - Christian Maaser
- Outpatients Department of Gastroenterology, IBD Center, Klinikum Lueneburg gGmbH, Lueneburg, Germany
| | - Torsten Kucharzik
- Department of Gastroenterology, Klinikum Lueneburg gGmbH, Lueneburg, Germany
| |
Collapse
|
17
|
Frias-Gomes C, Torres J, Palmela C. Intestinal Ultrasound in Inflammatory Bowel Disease: A Valuable and Increasingly Important Tool. GE-PORTUGUESE JOURNAL OF GASTROENTEROLOGY 2021; 29:223-239. [PMID: 35979252 PMCID: PMC9275009 DOI: 10.1159/000520212] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 09/08/2021] [Indexed: 11/19/2022]
Abstract
Background Intestinal ultrasound is emerging as a non-invasive tool for monitoring disease activity in inflammatory bowel disease patients due to its low cost, excellent safety profile, and availability. Herein, we comprehensively review the role of intestinal ultrasound in the management of these patients. Summary Intestinal ultrasound has a good accuracy in the diagnosis of Crohn's disease, as well as in the assessment of disease activity, extent, and evaluating disease-related complications, namely strictures, fistulae, and abscesses. Even though not fully validated, several scores have been developed to assess disease activity using ultrasound. Importantly, intestinal ultrasound can also be used to assess response to treatment. Changes in ultrasonographic parameters are observed as early as 4 weeks after treatment initiation and persist during short- and long-term follow-up. Additionally, Crohn's disease patients with no ultrasound improvement seem to be at a higher risk of therapy intensification, need for steroids, hospitalisation, or even surgery. Similarly to Crohn's disease, intestinal ultrasound has a good performance in the diagnosis, activity, and disease extent assessment in ulcerative colitis patients. In fact, in patients with severe acute colitis, higher bowel wall thickness at admission is associated with the need for salvage therapy and the absence of a significant decrease in this parameter may predict the need for colectomy. Short-term data also evidence the role of intestinal ultrasound in evaluating therapy response, with ultrasound changes observed after 2 weeks of treatment and significant improvement after 12 weeks of follow-up in ulcerative colitis. Key Messages Intestinal ultrasound is a valuable tool to assess disease activity and complications, and to monitor response to therapy. Even though longer prospective data are warranted, intestinal ultrasound may lead to a change in the paradigm of inflammatory bowel disease management as it can be used in a point-of-care setting, enabling earlier intervention if needed.
Collapse
Affiliation(s)
- Catarina Frias-Gomes
- Gastroenterology Division, Surgical Department, Hospital Beatriz Ângelo, Loures, Portugal
| | - Joana Torres
- Gastroenterology Division, Surgical Department, Hospital Beatriz Ângelo, Loures, Portugal
- Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal
| | - Carolina Palmela
- Gastroenterology Division, Surgical Department, Hospital Beatriz Ângelo, Loures, Portugal
- *Carolina Palmela,
| |
Collapse
|
18
|
Usefulness of radiographic targeting on the evaluation of the location of a patency capsule using abdominal ultrasonography. Eur J Gastroenterol Hepatol 2021; 33:1260-1265. [PMID: 34581688 DOI: 10.1097/meg.0000000000001999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
BACKGROUND AND AIM The usefulness of a radio-tag-free PillCam patency capsule (PatCap) has been reported to evaluate the patency of the small intestine. If the PatCap is not excreted within 33 h, the location of the failed PatCap must be confirmed. Although several methods for locating the failed PatCap have been reported, a universal method has not been established. In this study, we aimed to confirm the clinical feasibility of abdominal ultrasonography combined with abdominal X-ray in the determination of the location of a failed PatCap. PATIENTS AND METHODS Consecutive patients who were scheduled to undergo the capsule endoscopy and had received PatCap examination between July 2012 and September 2019 were retrospectively analyzed. Failed PatCap was assessed using ultrasonography combined with abdominal X-ray. RESULTS Among the eligible 250 patients, 129 retrieved the PatCap in their stool within 33 h after ingestion. Among the remaining 121 patients, abdominal X-ray was performed and the PatCaps were suspected to be in the small bowel in 57 patients. Among these 57 patients, abdominal ultrasonography identified 17 PatCaps in the small bowel. Among the selected 250 patients, 233 patients (93.2%) were eligible for capsule endoscopy examination, while 17 patients (6.8%) were not eligible. Capsule endoscopy passed through the small intestine without any incident. CONCLUSION We confirmed that the abdominal ultrasonography with a radiographic targeting of the PatCap location is a reliable indicator to avoid the risk of capsule endoscopy retention or impaction and can be performed in most hospitals and clinics.
Collapse
|
19
|
Suárez Ferrer C, Poza Cordón J, Crivillén Anguita O, Mayor Delgado P, Rueda García JL, Martín Arranz E, Sánchez Azofra M, Noci Belda J, García Ramírez L, Martín Arranz MD. Prognostic value of ultrasound activity and parietal healing in patients with Crohn's disease. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2021; 113:494-499. [PMID: 33261499 DOI: 10.17235/reed.2020.7347/2020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
INTRODUCTION the "treat to target" strategy for the management of patients with Crohn's disease (CD) requires simple, reliable and non-invasive tools for continuous monitoring of the disease. Intestinal ultrasound has been proposed as an emerging technique that could be very useful in this field. MATERIAL AND METHODS patients who had undergone an intestinal ultrasound in the clinical practice between February 2013 and October 2018 at our hospital were retrospectively included. The evolution of the patients during follow-up was assessed based on the presence of ultrasound activity and the therapeutic changes based on the results. RESULTS two hundred and seventy-seven CD patients were included and the median follow-up time was 24 months (range 5-73 months). Signs of ultrasound inflammatory activity were identified in 166 patients (60 %), and of them, treatment was escalated in 116 patients (70 %) based on the results of the ultrasound. Among patients with identified ultrasound activity, in 166 patients (60 %) the evolution was less favorable than in those without activity, with a shorter time until the next outbreak. Thus, the median disease-free survival (without outbreaks) after performing the ultrasound was 18 months when ultrasound activity was identified (although in most of the patients [70 %] the treatment had been escalated) vs 47 months in patients without ultrasound activity. However, these differences were not statistically significant (p < 0.0001). Among the 111 patients without ultrasound activity, those who achieved "parietal healing" (74 patients) had a better evolution with a 12 % subsequent outbreak vs 27 % during follow-up (p = 0.05). Thus, 15 % of patients with parietal healing had an outbreak vs 34 % of those who had not normalized the ultrasound findings after three years of follow-up. CONCLUSION intestinal ultrasound is a technique capable of detecting inflammatory activity in patients with Crohn's disease and the presence of ultrasound activity is a risk factor for a new outbreak of activity and/or clinical relapse. Likewise, the presence of "parietal or transmural healing" (PH) is associated with a better evolution of patients during follow-up. Thus, it could be a more precise objective to consider deep remission in CD, with intestinal ultrasound being a useful technique for this purpose.
Collapse
|
20
|
Novak KL, Nylund K, Maaser C, Petersen F, Kucharzik T, Lu C, Allocca M, Maconi G, de Voogd F, Christensen B, Vaughan R, Palmela C, Carter D, Wilkens R. Expert Consensus on Optimal Acquisition and Development of the International Bowel Ultrasound Segmental Activity Score [IBUS-SAS]: A Reliability and Inter-rater Variability Study on Intestinal Ultrasonography in Crohn's Disease. J Crohns Colitis 2021; 15:609-616. [PMID: 33098642 PMCID: PMC8023841 DOI: 10.1093/ecco-jcc/jjaa216] [Citation(s) in RCA: 116] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND AIMS Intestinal ultrasound [IUS] is an accurate, patient-centreed monitoring tool that objectively evaluates Crohn's disease [CD] activity. However no current, widely accepted, reproducible activity index exists to facilitate consistent IUS identification of inflammatory activity. The aim of this study is to identify key parameters of CD inflammation on IUS, evaluate their reliability, and develop an IUS index reflecting segmental activity. METHODS There were three phases: [1] expert consensus Delphi method to derive measures of IUS activity; [2] an initial, multi-expert case acquisition and expert interpretation of 20 blinded cases, to measure inter-rater reliability for individual measures; [3] refinement of case acquisition and interpretation by 12 international experts, with 30 blinded case reads with reliability assessment and development of a segmental activity score. RESULTS Delphi consensus: 11 experts representing seven countries identified four key parameters including: [1] bowel wall thickness [BWT]; [2] bowel wall stratification; [3] hyperaemia of the wall [colour Doppler imaging]; and [4] inflammatory mesenteric fat. Blind read: each variable exhibited moderate to substantial reliability. Optimal, standardised image and cineloop acquisition were established. Second blind read and score development: intra-class correlation coefficient [ICC] for BWT was almost perfect at 0.96 [0.94-0.98]. All four parameters correlated with the global disease activity assessment and were included in the final International Bowel Ultrasound Segmental Activity Score with almost perfect ICC (0.97 [0.95-0.99, p <0.001]). CONCLUSIONS Using expert consensus and standardised approaches, identification of key activity measurements on IUS has been achieved and a segmental activity score has been proposed, demonstrating excellent reliability.
Collapse
Affiliation(s)
- Kerri L Novak
- Division of Gastroenterology and Hepatology, Department of Medicine, University of Calgary, AB, Canada
| | - Kim Nylund
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Institute of Clinical Medicine, University in Bergen, Klinisk institutt 1, Bergen, Norway
| | - Christian Maaser
- Outpatient Department of Gastroenterology, Department of Geriatric Medicine, University Teaching Hospital Lueneburg, Lueneburg, Germany
| | - Frauke Petersen
- Department of Gastroenterology, University Teaching Hospital Lueneburg, Lueneburg, Germany
| | - Torsten Kucharzik
- Department of Gastroenterology, University Teaching Hospital Lueneburg, Lueneburg, Germany
| | - Cathy Lu
- Division of Gastroenterology and Hepatology, Department of Medicine, University of Calgary, AB, Canada
| | - Mariangela Allocca
- Humanitas Clinical and Research Centre, Rozzano, Italy
- Humanitas University, Department of Biomedical Sciences, Milan, Italy
| | - Giovanni Maconi
- Gastroenterology Unit, Department of Biomedical and Clinical Sciences. FBF- L.Sacco University Hospital, Milan. Italy
| | - Floris de Voogd
- Department of Gastroenterology and Hepatology, Amsterdam University Medical Centre, Amsterdam, The Netherlands
| | - Britt Christensen
- Department of Gastroenterology, Royal Melbourne Hospital, Parkville, VIC Australia
| | - Rose Vaughan
- Department of Gastroenterology, Royal Melbourne Hospital, Parkville, VIC Australia
| | - Carolina Palmela
- Division of Gastroenterology, Department of General Surgery, Hospital Beatriz Ângelo, Loures, Portugal
| | - Dan Carter
- Department of Gastroenterology, Chaim Sheba Medical Centre, Tel Hashomer, Israel and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Rune Wilkens
- Gastrounit, Division of Medicine, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark
- Copenhagen Centre for Inflammatory Bowel Disease in Children, Adolescents and Adults, University of Copenhagen, Hvidovre Hospital, Copenhagen, Denmark
| |
Collapse
|
21
|
Marin AM, Calapod OP, Moldoveanu AC, Tribus LC, Fierbințeanu-Braticevici C. Non-invasive Ultrasonographic Score for Assessment of the Severity of Inflammatory Bowel Disease. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:932-940. [PMID: 33388210 DOI: 10.1016/j.ultrasmedbio.2020.11.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 10/28/2020] [Accepted: 11/22/2020] [Indexed: 06/12/2023]
Abstract
Intestinal ultrasound and shear wave elastography have gained increasing interest because of their promising results in the assessment of inflammatory bowel disease. The aim of this study was to find an ultrasonographic score to replace invasive endoscopic procedures for the management of these patients. The score includes ultrasound parameters that correlate well with clinical severity scales and inflammatory markers: bowel wall thickness, the Limberg score, disease extension and acoustic radiation force impulse measurements. The score proved to be well correlated with the Harvey Bradshaw Index, the Mayo score, C-reactive protein and fecal calprotectin. For Crohn's disease, a cutoff value of 8 points could identify active disease with 81.81% sensitivity and 83% specificity, while for ulcerative colitis, a cutoff value of 7 points could discriminate between remission and relapse with 86.85% sensitivity and 94% specificity. In conclusion, our ultrasonographic score can differentiate relapse from remission in inflammatory bowel disease.
Collapse
Affiliation(s)
- Andreea Maria Marin
- Carol Davila University of Medicine and Pharmacy Bucharest, Bucharest, Romania
| | - Ovidiu Paul Calapod
- Carol Davila University of Medicine and Pharmacy Bucharest, Bucharest, Romania; Gastroenterology Department, Bucharest Emergency University Hospital, Bucharest, Romania
| | - Alexandru Constantin Moldoveanu
- Carol Davila University of Medicine and Pharmacy Bucharest, Bucharest, Romania; Gastroenterology Department, Bucharest Emergency University Hospital, Bucharest, Romania
| | - Laura Carina Tribus
- Carol Davila University of Medicine and Pharmacy Bucharest, Bucharest, Romania; Gastroenterology Department, Bucharest Emergency University Hospital, Bucharest, Romania.
| | - Carmen Fierbințeanu-Braticevici
- Carol Davila University of Medicine and Pharmacy Bucharest, Bucharest, Romania; Gastroenterology Department, Bucharest Emergency University Hospital, Bucharest, Romania
| |
Collapse
|
22
|
Esterson A, Alpert EA, Gabrieli S, Granat N. Sonographic assessment of inflammatory bowel disease in the emergency department: A case series and review of the literature. JOURNAL OF CLINICAL ULTRASOUND : JCU 2021; 49:277-281. [PMID: 33277932 DOI: 10.1002/jcu.22946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 09/09/2020] [Accepted: 10/27/2020] [Indexed: 06/12/2023]
Abstract
The use of sonography for diagnosing inflammatory bowel disease (IBD) has been reported in the radiology literature but is not common practice in the hands of emergency physicians (EPs). We present a series of three cases where IBD was managed by an EP using point-of-care ultrasonography (POCUS), and discuss the sonographic features of IBD including bowel wall thickening, increased blood flow on color Doppler, infiltration of surrounding fatty tissue, and presence of intraperitoneal fluid. Complications such as bowel strictures and peri-colic abscess are also described. We suggest that the use of POCUS for the assessment of IBD patients in the ED may expedite both diagnosis and treatment, as well as minimize the use of additional imaging.
Collapse
Affiliation(s)
- Akiva Esterson
- Department of Emergency Medicine, Beilinson Hospital, Rabin Medical Center, Petah Tikva, Israel
| | - Evan Avraham Alpert
- Department of Emergency Medicine, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Selma Gabrieli
- Department of Diagnostic Imaging, Hasharon Hospital, Rabin Medical Center, Petah Tikva, Israel
| | - Nadav Granat
- Department of Emergency Medicine, Beilinson Hospital, Rabin Medical Center, Petah Tikva, Israel
- Department of Diagnostic Imaging, Hasharon Hospital, Rabin Medical Center, Petah Tikva, Israel
| |
Collapse
|
23
|
Allocca M, Furfaro F, Fiorino G, Peyrin-Biroulet L, Danese S. Point-of-Care Ultrasound in Inflammatory Bowel Disease. J Crohns Colitis 2021; 15:143-151. [PMID: 32674146 DOI: 10.1093/ecco-jcc/jjaa151] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Inflammatory bowel diseases [IBD], including Crohn's disease [CD] and ulcerative colitis [UC], are chronic, relapsing and destructive inflammatory disorders of the gastrointestinal tract which can lead to organ damage and impair quality of life. A 'treat-to-target' strategy based on activity and severity of disease and response to treatment with close monitoring of intestinal inflammation is recommended. Ileocolonoscopy [CS] is considered the first-line procedure for the assessment of IBD, and magnetic resonance enterography [MRE] is the current standard for assessing the small bowel and complications in CD, and has been proposed as an alternative procedure to CS in the evaluation of both ileo-colonic CD and UC. As that both CS and MRE are invasive and expensive procedures and unappealing to patients, they are unfeasible as frequent and repetitive tools for the monitoring of disease activity. Bowel ultrasound [US] represents a well-tolerated, non-invasive and cost-effective modality to manage IBD patients in clinical practice. Compared to CS and MRE, bowel US has been shown to have the same level of accuracy in assessing and monitoring disease activity and severity of both CD and UC. It can be performed at the point-of-care and therefore allow for real-time clinical decision-making. Point-of-care ultrasound [POCUS] is suggested as the stethoscope of the future and is gaining interest and diffusion in the medical field because it can be used for the bedside examination of patients. The aim of this review is to discuss point-of-care bowel ultrasound [POCBUS] in the management of patients with IBD.
Collapse
Affiliation(s)
- Mariangela Allocca
- Humanitas Clinical and Research Center - IRCCS, via Manzoni 56, Rozzano (Mi), Italy.,Humanitas University, Department of Biomedical Sciences, Via Rita Levi Montalcini 4, Pieve Emanuele - Milan, Italy
| | - Federica Furfaro
- Humanitas Clinical and Research Center - IRCCS, via Manzoni 56, Rozzano (Mi), Italy
| | - Gionata Fiorino
- Humanitas Clinical and Research Center - IRCCS, via Manzoni 56, Rozzano (Mi), Italy.,Humanitas University, Department of Biomedical Sciences, Via Rita Levi Montalcini 4, Pieve Emanuele - Milan, Italy
| | - Laurent Peyrin-Biroulet
- Department of Gastroenterology and Inserm U954, University Hospital of Nancy, Lorraine University, Nancy, France
| | - Silvio Danese
- Humanitas Clinical and Research Center - IRCCS, via Manzoni 56, Rozzano (Mi), Italy.,Humanitas University, Department of Biomedical Sciences, Via Rita Levi Montalcini 4, Pieve Emanuele - Milan, Italy
| |
Collapse
|
24
|
De Voogd F, Wilkens R, Gecse K, Allocca M, Novak K, Lu C, D’Haens G, Maaser C. A Reliability Study: Strong Inter-Observer Agreement of an Expert Panel for Intestinal Ultrasound in Ulcerative Colitis. J Crohns Colitis 2021; 15:1284-1290. [PMID: 33420784 PMCID: PMC8328294 DOI: 10.1093/ecco-jcc/jjaa267] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Intestinal ultrasound [IUS] is a promising and non-invasive cross-sectional imaging modality in the diagnosis and monitoring of ulcerative colitis [UC]. Unlike endoscopy, where standardized scoring for evaluation of disease activity is widely used, scoring for UC with IUS is currently unavailable. Therefore, we conducted a study to assess the reliability of IUS in UC among expert sonographists in order to identify robust parameters. METHODS Thirty patients with both clinically active [25] and quiescent [five] UC were included. Six expert sonographers first agreed upon key IUS parameters and grading, including bowel wall thickness [BWT], colour Doppler signal [CDS], inflammatory fat [i-fat], loss of bowel wall stratification [BWS], loss of haustrations and presence of lymph nodes. Thirty video-recorded cases were blindly reviewed. RESULTS Inter-observer agreement was almost perfect for BWT (intra-class correlation coefficient [ICC]: 0.96) and substantial for CDS [κ = 0.63]. Agreement was moderate for presence of lymph nodes [κ = 0.41] and fair for presence of i-fat [κ = 0.36], BWS [κ = 0.24] and loss of haustrations [κ = 0.26]. Furthermore, there was substantial agreement for presence of disease activity on IUS [κ = 0.77] and almost perfect agreement for disease severity [ICC: 0.93]. Most individual parameters showed a strong association with IUS disease activity as measured by the six readers. CONCLUSION IUS is a reliable imaging modality to assess disease activity and severity in UC. Important individual parameters such as BWT and CDS are reliable and could be incorporated in a future UC scoring index. Standardized acquisition and assessment of UC utilizing IUS with established reliability is important to expand the use of IUS globally.
Collapse
Affiliation(s)
- Floris De Voogd
- Amsterdam University Medical Center, Department of Gastroenterology and Hepatology, Amsterdam, The Netherlands,Corresponding author: Dr F. de Voogd, Amsterdam University Medical Centers, Department of Gastroenterology and Hepatology, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
| | - Rune Wilkens
- Gastrounit, Division of Medicine, Hvidovre Hospital, Copenhagen, Denmark
| | - Krisztina Gecse
- Amsterdam University Medical Center, Department of Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | | | - Kerri Novak
- Division of Gastroenterology, Department of Medicine, University of Calgary, Alberta, Canada
| | - Cathy Lu
- Division of Gastroenterology, Department of Medicine, University of Calgary, Alberta, Canada
| | - Geert D’Haens
- Amsterdam University Medical Center, Department of Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | - Christian Maaser
- Outpatient’s Department of Gastroenterology, University Teaching Hospital Lueneburg Germany
| |
Collapse
|
25
|
Ripollés T, Poza J, Suarez Ferrer C, Martínez-Pérez MJ, Martín-Algíbez A, de Las Heras Paez B. Evaluation of Crohn's Disease Activity: Development of an Ultrasound Score in a Multicenter Study. Inflamm Bowel Dis 2021; 27:145-154. [PMID: 32507880 DOI: 10.1093/ibd/izaa134] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Indexed: 01/09/2023]
Abstract
OBJECTIVE Our goal in this multicentric prospective study was 2-fold: first, to test the diagnostic accuracy of ultrasound, color Doppler imaging (CDI), and contrast-enhanced ultrasound (CEUS) in identifying disease activity in patients with Crohn's disease (CD) compared with endoscopy as the reference standard; and, second, to construct a sonographic score that allows disease activity to be detected. MATERIALS AND METHODS Seventy-two patients with CD from 3 hospitals underwent within a 30-day period both colonoscopy and ultrasound (US), including mural thickness, CDI, and CEUS, prospectively as part of clinical care. A multivariate analysis was carried out to assess the influence of each of the ultrasound variables in predicting endoscopic activity. We then developed a predictive ultrasound score for disease activity, and a receiver operating characteristic (ROC) curve was constructed to determine the area under the ROC curve (AUC) and the best cut-off score value to discriminate between active and inactive disease. RESULTS Sonographic findings that were independent predictors of the presence of active disease at endoscopy were wall thickness, color grade, and contrast parameters. A score based on those variables showed high accuracy in predicting active disease, with an area under the ROC curve of 0.972. A simpler index, without contrast parameters, also showed high accuracy in detecting disease activity (AUC, 0.923). CONCLUSION A score based on wall thickness, color Doppler grade, and contrast parameters showed high accuracy in predicting active disease. A score without including the use of contrast agent had practically similar results and is easier to use in monitoring response to treatment.
Collapse
Affiliation(s)
- Tomás Ripollés
- Department of Radiology, Hospital Universitario Dr. Peset, Valencia, Spain
| | - Joaquín Poza
- Department of Gastroenterology, Hospital Universitario La Paz, Madrid, Spain
| | | | | | - Ana Martín-Algíbez
- Department of Gastroenterology, Hospital Universitario 12 Octubre, Madrid, Spain
| | | |
Collapse
|
26
|
Gonzalez-Montpetit E, Ripollés T, Martinez-Pérez MJ, Vizuete J, Martín G, Blanc E. Ultrasound findings of Crohn's disease: correlation with MR enterography. Abdom Radiol (NY) 2021; 46:156-167. [PMID: 32607648 DOI: 10.1007/s00261-020-02622-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/08/2020] [Accepted: 06/13/2020] [Indexed: 12/17/2022]
Abstract
Crohn's disease is a chronic inflammatory bowel disease characterized by periods of relative inactivity alternating with acute flare-ups. Imaging techniques play a fundamental role in the diagnosis and follow-up of Crohn's disease, providing information on the extent of disease, disease activity, and the presence of extramural complications. Because of the frequent re-evaluation required by the relapsing nature of Crohn's disease and the relative young age at which most patients are diagnosed, techniques that use ionizing radiation are best avoided in monitoring this population. Thus, magnetic resonance enterography (MRE) and ultrasonography (US) are the preferable techniques. Various studies have demonstrated that US is accurate in assessing the gut. Despite some clear advantages over MRE, US has long been underused in the evaluation of intestinal disease. This review presents an overview of the main imaging findings in Crohn's disease, correlating representative US images with MRE and surgical pathology specimens. We conclude that US reliably depicts both bowel-related and mesenteric features of Crohn's disease and US findings correlate strongly with MRE findings.
Collapse
Affiliation(s)
- Estefania Gonzalez-Montpetit
- Section of Abdominal Imaging at the Radiology Department, Hospital Universitario Doctor Peset, Valencia, Spain.
- Abdominal Imaging, Centre IDI Girona, Hospital Universitario Doctor Josep Trueta, Avinguda de França s/n, 17007, Girona, Spain.
| | - Tomás Ripollés
- Section of Abdominal Imaging at the Radiology Department, Hospital Universitario Doctor Peset, Valencia, Spain
| | - María J Martinez-Pérez
- Section of Abdominal Imaging at the Radiology Department, Hospital Universitario Doctor Peset, Valencia, Spain
| | - José Vizuete
- Section of Abdominal Imaging at the Radiology Department, Hospital Universitario Doctor Peset, Valencia, Spain
| | - Gregorio Martín
- Section of Abdominal Imaging at the Radiology Department, Hospital Universitario Doctor Peset, Valencia, Spain
| | - Esther Blanc
- Section of Abdominal Imaging at the Radiology Department, Hospital Universitario Doctor Peset, Valencia, Spain
| |
Collapse
|
27
|
Ripollés T, Muñoz F, Martínez-Pérez M, de Miguel E, Poza Cordón J, de la Heras Páez de la Cadena B. Usefulness of intestinal ultrasound in inflammatory bowel disease. RADIOLOGIA 2021. [DOI: 10.1016/j.rxeng.2020.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
28
|
Muñoz F, Ripollés T, Poza Cordón J, de Las Heras Páez de la Cadena B, Martínez-Pérez MJ, de Miguel E, Zabana Y, Mañosa Ciria M, Beltrán B, Barreiro-de Acosta M. Recommendations of the Spanish Working Group on Crohn's Disease and Ulcerative Colitis (GETECCU) on the use of abdominal ultrasound in inflammatory bowel disease. GASTROENTEROLOGIA Y HEPATOLOGIA 2020; 44:158-174. [PMID: 33309386 DOI: 10.1016/j.gastrohep.2020.05.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 05/22/2020] [Indexed: 10/22/2022]
Abstract
Ultrasound has an excellent diagnostic performance when Crohn's disease is suspected, when performing an activity assessment, or determining the extension and location of Crohn's disease, very similar to other examinations such as MRI or CT. It has a good correlation with endoscopic lesions and allows the detection of complications such as strictures, fistulas or abscesses. It complements colonoscopy in the diagnosis and, given its tolerance, cost and immediacy, it can be considered as a good tool for disease monitoring. In ulcerative colitis, its role is less relevant, being limited to assessing the extent and activity when it is not possible with other diagnostic techniques or if there are doubts with these. Despite its advantages, its use in inflammatory bowel disease (IBD) is not widespread in Spain. For this reason, this document reviews the advantages and disadvantages of the technique to promote knowledge about it and implementation of it in IBD Units.
Collapse
Affiliation(s)
- Fernando Muñoz
- Servicio de Digestivo. Complejo Asistencial Universitario de Salamanca, España.
| | - Tomás Ripollés
- Servicio Radiodiagnóstico, Hospital Universitario Dr. Peset, Valencia, España
| | - Joaquín Poza Cordón
- Servicio de Aparato Digestivo del Hospital Universitario La Paz, Madrid, España
| | | | | | - Enrique de Miguel
- Servicio de Radiodiagnóstico, Hospital General Universitario Gregorio Marañón, Madrid, España
| | - Yamile Zabana
- Servicio de Gastroenterología, Unidad de Enfermedad Inflamatoria Intestinal, Hospital Universitari Mútua de Terrassa, CIBERehd, Barcelona, España
| | - Miriam Mañosa Ciria
- Unidad de EII. Servei d'Aparell digestiu. Hospital Universitari Germans Trias i Pujol, CIBERehd, Barcelona, España
| | - Belén Beltrán
- Servicio de Medicina Digestiva, Hospital Universitario La Fe, CIBERehd, Valencia, España
| | - Manuel Barreiro-de Acosta
- Unidad EII. Servicio de Aparato Digestivo. Hospital Clínico Universitario de Santiago, A Coruña, España
| |
Collapse
|
29
|
Ripollés T, Muñoz F, Martínez-Pérez MJ, de Miguel E, Cordón JP, de la Heras Páez de la Cadena B. Usefulness of intestinal ultrasound in inflammatory bowel disease. RADIOLOGIA 2020; 63:89-102. [PMID: 33189372 DOI: 10.1016/j.rx.2020.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 08/30/2020] [Accepted: 10/02/2020] [Indexed: 02/07/2023]
Abstract
Imaging techniques play a fundamental role in the initial diagnosis and follow-up of inflammatory bowel disease. Intestinal ultrasound has high sensitivity and specificity in patients with suspected Crohn's disease and in the detection of inflammatory activity. This technique enables the early diagnosis of intra-abdominal complications such as stenosis, fistulas, and abscesses. It has also proven useful in monitoring the response to treatment and in detecting postsurgical recurrence. Technical improvements in ultrasound scanners, technological advances such as ultrasound contrast agents and elastography, and above all increased experience have increased the role of ultrasound in the evaluation of the gastrointestinal tract. The features that make ultrasound especially attractive include its wide availability, its noninvasiveness and lack of ionizing radiation, its low cost, and its good reproducibility, which is important because it is easy to repeat the study and the study is well tolerated during follow-up. This review summarizes the role of intestinal ultrasound in the detection and follow-up of inflammatory bowel disease.
Collapse
Affiliation(s)
- T Ripollés
- Servicio de Radiología, Hospital Dr. Peset, Valencia, España.
| | - F Muñoz
- Servicio de Digestivo, Complejo Asistencial Universitario de Salamanca, Salamanca, España
| | | | - E de Miguel
- Servicio de Radiología, Hospital General Universitario Gregorio Marañón, Madrid, España
| | - J Poza Cordón
- Servicio de Digestivo, Hospital Universitario La Paz, Madrid, España
| | | |
Collapse
|
30
|
Taylor SA, Mallett S, Bhatnagar G, Morris S, Quinn L, Tomini F, Miles A, Baldwin-Cleland R, Bloom S, Gupta A, Hamlin PJ, Hart AL, Higginson A, Jacobs I, McCartney S, Murray CD, Plumb AA, Pollok RC, Rodriguez-Justo M, Shabir Z, Slater A, Tolan D, Travis S, Windsor A, Wylie P, Zealley I, Halligan S. Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing Crohn's disease patients: the METRIC diagnostic accuracy study. Health Technol Assess 2020; 23:1-162. [PMID: 31432777 DOI: 10.3310/hta23420] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. OBJECTIVE To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. DESIGN Prospective multicentre cohort study. SETTING Eight NHS hospitals. PARTICIPANTS Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. INTERVENTIONS Magnetic resonance enterography and ultrasonography. MAIN OUTCOME MEASURES The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. RESULTS Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%; p = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. LIMITATIONS Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. CONCLUSIONS Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. TRIAL REGISTRATION Current Controlled Trials ISRCTN03982913. FUNDING This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 42. See the NIHR Journals Library website for further project information.
Collapse
Affiliation(s)
- Stuart A Taylor
- Centre for Medical Imaging, University College London, London, UK
| | - Sue Mallett
- Institute of Applied Health Research, National Institute for Health Research Birmingham Biomedical Research Centre, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | | | - Stephen Morris
- Applied Health Research, University College London, London, UK
| | - Laura Quinn
- Institute of Applied Health Research, National Institute for Health Research Birmingham Biomedical Research Centre, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | - Florian Tomini
- Applied Health Research, University College London, London, UK
| | - Anne Miles
- Department of Psychological Sciences, Birkbeck, University of London, London, UK
| | - Rachel Baldwin-Cleland
- Intestinal Imaging Centre, St Mark's Hospital, London North West University Healthcare NHS Trust, Harrow, UK
| | - Stuart Bloom
- Department of Gastroenterology, University College Hospital, London, UK
| | - Arun Gupta
- Intestinal Imaging Centre, St Mark's Hospital, London North West University Healthcare NHS Trust, Harrow, UK
| | - Peter John Hamlin
- Department of Gastroenterology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Ailsa L Hart
- Inflammatory Bowel Disease Unit, St Mark's Hospital, London North West University Healthcare NHS Trust, Harrow, UK
| | - Antony Higginson
- Department of Radiology, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Ilan Jacobs
- Independent patient representative, c/o Centre for Medical Imaging, University College London, London, UK
| | - Sara McCartney
- Department of Gastroenterology, University College Hospital, London, UK
| | - Charles D Murray
- Department of Gastroenterology and Endoscopy, Royal Free London NHS Foundation Trust, London, UK
| | - Andrew Ao Plumb
- Centre for Medical Imaging, University College London, London, UK
| | - Richard C Pollok
- Department of Gastroenterology, St George's Hospital, London, UK
| | | | - Zainib Shabir
- Comprehensive Clinical Trials Unit, Institute of Clinical Trials and Methodology, University College London, London, UK
| | - Andrew Slater
- Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Damian Tolan
- Department of Radiology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Simon Travis
- Translational Gastroenterology Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | | | - Peter Wylie
- Department of Radiology, Royal Free London NHS Foundation Trust, London, UK
| | - Ian Zealley
- Department of Radiology, Ninewells Hospital, Dundee, UK
| | - Steve Halligan
- Centre for Medical Imaging, University College London, London, UK
| |
Collapse
|
31
|
Abstract
Purpose To prospectively evaluate interobserver agreement for small bowel ultrasound (SBUS) in newly diagnosed and relapsing Crohn’s disease. Methods A subset of patients recruited to a prospective trial comparing the diagnostic accuracy of MR enterography and SBUS underwent a second SBUS performed by one of a pool of six practitioners, who recorded the presence, activity and location of small bowel and colonic disease. Detailed segmental mural and extra-mural observations were also scored. Interobserver variability was expressed as percentage agreement with a construct reference standard, split by patient cohort, grouping disease as present or absent. Prevalence adjusted bias adjusted kappa (PABAK), and simple percentage agreement between practitioners, irrespective of the reference standard, were calculated. Results Thirty-eight patients (11 new diagnosis, 27 relapse) were recruited from two sites. Overall percentage agreement for small bowel disease presence against the consensus reference was 82% (52–95% (95%CI)), kappa coefficient (κ) 0.64, (substantial agreement) for new diagnosis and 81%, κ 0.63 (substantial agreement) for the relapsing cohort. Agreement for colonic disease presence was 64%, κ 0.27 (fair agreement) in new diagnosis and 78%,κ 0.56 (moderate agreement) in the relapsing cohort. Simple agreement between practitioners was 84% and 87% for small bowel and colonic disease presence respectively. Practitioners agreed on small bowel disease activity in 24/27 (89%) where both identified disease. Kappa agreement for detailed mural observations ranged from κ 0.00 to 1.00. Conclusion There is substantial practitioner agreement for small bowel disease presence in newly diagnosed and relapsing CD patients, supporting wider dissemination of enteric US. Electronic supplementary material The online version of this article (10.1007/s00261-020-02405-w) contains supplementary material, which is available to authorized users.
Collapse
|
32
|
Sævik F, Eriksen R, Eide GE, Gilja OH, Nylund K. Development and Validation of a Simple Ultrasound Activity Score for Crohn's Disease. J Crohns Colitis 2020; 15:115-124. [PMID: 32504533 PMCID: PMC7805799 DOI: 10.1093/ecco-jcc/jjaa112] [Citation(s) in RCA: 69] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND AND AIMS To improve management of patients with Crohn's disease, objective measurements of disease activity are needed. Ileocolonoscopy is the current reference standard but has limitations that restrict repeated use. Ultrasonography is potentially useful for activity monitoring, but no validated sonographic activity index is currently in widespread use. Thus, we aimed to construct and validate a simple ultrasound score for Crohn's disease. METHODS Forty patients were prospectively examined with ultrasound and endoscopy in the development phase. The Simple Endoscopic Score for Crohn's Disease [SES-CD] was used as a reference standard. Seven ultrasound variables [bowel wall thickness, length, colour Doppler, stenosis, fistula, stratification and fatty wrapping] were initially included, and multiple linear regression was used to select the variables that should be included in the final score. Second, the ultrasound data from each patient were re-examined for interobserver assessment using weighted kappa and intraclass correlation. Finally, the activity index was validated in a new cohort of 124 patients. RESULTS Length, fistula and stenosis were excluded. The combination of the remaining variables provided a multiple correlation coefficient of r = 0.78. Interobserver analysis revealed poor agreement for stratification and fatty wrapping and these were thus excluded. There was excellent interobserver agreement for the remaining score consisting of wall thickness and colour Doppler. In both patient cohorts, the ultrasound score correlated well with SES-CD [Development cohort: rho = 0.83, p < 0.001, Validation cohort: rho = 0.78, p < 0.001]. A receiver operating characteristic curve analysis revealed an area under the curve of 0.92 and 0.88 for detecting endoscopic activity and moderate endoscopic activity, respectively. CONCLUSIONS A simple ultrasound activity index for Crohn's disease consisting of bowel wall thickness and colour Doppler was constructed and validated and correlated well with endoscopic disease activity.ClinicalTrials. gov ID: NCT03481751.
Collapse
Affiliation(s)
- Fredrik Sævik
- Department of Clinical Medicine, University of Bergen, Bergen, Norway,National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway,Corresponding author: Fredrik Sævik, MD, Department of Clinical Medicine, University of Bergen, Haukeland University Hospital, Jonas Lies vei, N-5021 Bergen, Norway. Tel: +47 40 01 39 10; Fax: + 47 55 97 29 50;
| | - Ragnar Eriksen
- Department of Medicine, Ålesund Hospital, Ålesund, Norway
| | - Geir Egil Eide
- Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway,Centre for Clinical Research, Haukeland University Hospital, Bergen, Norway
| | - Odd Helge Gilja
- Department of Clinical Medicine, University of Bergen, Bergen, Norway,National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
| | - Kim Nylund
- Department of Clinical Medicine, University of Bergen, Bergen, Norway,National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
| |
Collapse
|
33
|
Allocca M, Danese S, Laurent V, Peyrin-Biroulet L. Use of Cross-Sectional Imaging for Tight Monitoring of Inflammatory Bowel Diseases. Clin Gastroenterol Hepatol 2020; 18:1309-1323.e4. [PMID: 31812657 DOI: 10.1016/j.cgh.2019.11.052] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 11/06/2019] [Accepted: 11/15/2019] [Indexed: 02/07/2023]
Abstract
A treat-to-target strategy with close monitoring of intestinal inflammation is recommended in inflammatory bowel disease (IBD). Ileocolonoscopy remains the gold standard for assessing disease activity in IBD but is a relatively invasive procedure and is impossible to repeat in the context of tight monitoring strategies. In addition to biomarkers, cross-sectional imaging increasingly is used in these patients. Computed tomography is limited by the use of radiation, while the use of magnetic resonance enterography (MRE) is limited by its cost and access. There is growing interest in bowel ultrasound that represents a cost-effective, noninvasive, and well-tolerated modality in clinical practice, but it is operator dependent. Compared with ileocolonoscopy and MRE, bowel US has been shown to have the same level of accuracy in assessing and monitoring disease activity for both CD and UC and thus can be considered a point-of-care test. Diffusion-weighted imaging (DWI) is a MR imaging technique that increasingly is used in both IBD and non-IBD conditions and has been shown to be a valuable and accurate tool for assessing and monitoring IBD activity. Compared with conventional MRE, DWI is quicker, less time consuming, may not require intravenous contrast agent, fasting, bowel cleansing, oral preparation, or rectal preparation. This review discusses the role of these cross-sectional imaging techniques for the management of patients with IBD. In the near future, the value of DWI and ultrasound in assessing IBD will require further investigation in the era of transmural healing in CD and complete mucosal healing, including histologic remission, in ulcerative colitis.
Collapse
Affiliation(s)
- Mariangela Allocca
- Inflammatory Bowel Disease Centre, Humanitas Clinical and Research Centre, Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, Rozzano, Milan, Italy
| | - Silvio Danese
- Inflammatory Bowel Disease Centre, Humanitas Clinical and Research Centre, Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, Rozzano, Milan, Italy
| | - Valérie Laurent
- Department of Radiology, Nancy University Hospital, Lorraine University, Vandœuvre-lès-Nancy, France
| | - Laurent Peyrin-Biroulet
- Department of Gastroenterology, Inserm NGERE, University Hospital of Nancy, Lorraine University, Nancy, France.
| |
Collapse
|
34
|
Consistency of Trans-Abdominal and Water-Immersion Ultrasound Images of Diseased Intestinal Segments in Crohn's Disease. Diagnostics (Basel) 2020; 10:diagnostics10050267. [PMID: 32365572 PMCID: PMC7277370 DOI: 10.3390/diagnostics10050267] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/25/2020] [Accepted: 04/27/2020] [Indexed: 12/13/2022] Open
Abstract
The aim of this study is to clarify whether trans-abdominal ultrasound (TAUS) can reflect actual intestinal conditions in Crohn’s disease (CD) as effectively as water-immersion ultrasound (WIUS) does. This retrospective study enrolled 29 CD patients with 113 intestinal lesions. Five ultrasound (US) parameters (distinct presence/indistinct presence/disappearance of wall stratification in the submucosal and mucosal layers; thickened submucosal layer; irregular mucosal surface; increased fat wrapping around the bowel wall; and fistula signs) that may indicate different states in CD were determined by TAUS and WIUS for the same lesion. Using WIUS as a reference standard, the sensitivity, specificity, and accuracy of TAUS were calculated. The degree of agreement between TAUS and WIUS was evaluated by the kappa coefficient. All US parameters of TAUS had an accuracy >70% (72.6–92.7%). The highest efficacy of TAUS was obtained for fistula signs (sensitivity, specificity, and accuracy values were 63.6%, 96.0%, and 92.7%, respectively). All US parameters between TAUS and WIUS had a definitive (p ≤ 0.001) and moderate-to-substantial consistency (kappa value = 0.446–0.615). The images of TAUS showed substantial similarity to those of WIUS, suggesting that TAUS may function as a substitute to evaluate the actual intestinal conditions of CD.
Collapse
|
35
|
Abstract
Ultrasonography (US) is often the first-line imaging study used to evaluate women who present with acute or chronic pelvic pain. Detection of nongynecologic causes of pelvic pain is critical, because delay in diagnosis can cause significant morbidity and mortality. Evaluation of these entities requires a variety of transducers to achieve optimal imaging depth and changes in patient positioning. Specific imaging techniques (such as graded compression) may be required if bowel pathology is suspected. Contrast-enhanced ultrasonography is increasingly used to improve detection of certain entities. The US appearance of common gastrointestinal and urinary tract-related causes of pelvic pain is reviewed.
Collapse
|
36
|
Costantino A, Giunta M, Casazza G, Arona S, Colli A, Conte D, Vecchi M, Fraquelli M. Is pocket-size ultrasound a reliable tool for bowel investigation? A study on its feasibility, reproducibility and diagnostic accuracy. Dig Liver Dis 2020; 52:38-43. [PMID: 31409578 DOI: 10.1016/j.dld.2019.07.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 06/26/2019] [Accepted: 07/12/2019] [Indexed: 12/11/2022]
Abstract
BACKGROUND Intestinal ultrasound (IUS) examination is a first-line non-invasive imaging procedure for patients with suspicion of bowel diseases. AIM To assess the feasibility, reproducibility and diagnostic accuracy of a pocket-size ultrasound device (PUD) in identifying the presence of intestinal alterations in patients consecutively recruited to undergo IUS examination. METHODS 200 consecutive patients (57% female, 48.8 years) underwent both PUD (two independent investigators) and IUS examination on the same day. Nine ultrasonographic signs were systematically searched for. PUD inter-observer reproducibility was assessed by kappa statistic and ICC. The diagnostic accuracy of PUD as compared to IUS results was assessed by calculating sensitivity, specificity and corresponding positive and negative likelihood ratios. RESULTS PUD and IUS examinations were successful in 100% of the patients. PUD reproducibility was good/excellent at evidencing the presence (ICC 0.84) and length (ICC 0.85) of an intestinal tract with thickened wall and abdominal free fluid (ICC 0.87). The diagnostic accuracy of PUD, compared to traditional IUS, was good with regard to the presence of bowel wall thickening (sensitivity 92%, specificity 95%), the length of the thickened bowel (sensitivity 94%, specificity 95%) and the presence of free fluid (sensitivity 81%, specificity 99%). CONCLUSIONS PUD is a feasible, reproducible and accurate first-line screening tool for the assessment of the gastro-intestinal tract.
Collapse
Affiliation(s)
- Andrea Costantino
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Università di Milano, Milan, Italy
| | | | - Giovanni Casazza
- Dipartimento di Scienze Biomediche e Cliniche, Ospedale "L. Sacco", Università degli Studi di Milano, Milan, Italy
| | - Silvia Arona
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Università di Milano, Milan, Italy
| | - Agostino Colli
- Dipartimento di Medicina Interna, Ospedale "A. Manzoni", Lecco, Italy
| | - Dario Conte
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Università di Milano, Milan, Italy
| | - Maurizio Vecchi
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Università di Milano, Milan, Italy
| | - Mirella Fraquelli
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Università di Milano, Milan, Italy.
| |
Collapse
|
37
|
Fraquelli M, Castiglione F, Calabrese E, Maconi G. Impact of intestinal ultrasound on the management of patients with inflammatory bowel disease: how to apply scientific evidence to clinical practice. Dig Liver Dis 2020; 52:9-18. [PMID: 31732443 DOI: 10.1016/j.dld.2019.10.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 09/27/2019] [Accepted: 10/08/2019] [Indexed: 12/11/2022]
Abstract
Technological improvements and growing sonographers' expertise boost the role of intestinal ultrasound (IUS) in assessing patients with inflammatory bowel diseases (IBD). Non-invasiveness, low cost and good reproducibility make IUS attractive. Leveraging on the Authors' long-term field experience, this review focuses on the IUS role in IBD patients' clinical management. For detecting IBD, particularly Crohn's disease, the IUS parameters - above all the evidence of a thickened bowel wall (BWT) - show very good diagnostic accuracy similar to that of MRI or CT scan. The standard IUS parameters are not accurate enough to detect inflammatory activity, but intravenous contrast-enhanced US (CEUS) is highly accurate in ruling active inflammation out. However, its routinely use remains limited in clinical practice and its parameters need standardization. IUS is accurate in detecting IBD main complications: in particular, fistulae and abscesses. As to stenosis the recent introduction of IUS-based elastographic techniques allows to differentiate prevalently inflammatory from highly fibrotic strictures. IUS proves valid also for monitoring IBD patients. In particular, the evidence of transmural healing, defined as BWT normalization, has got an important prognostic meaning, as associated with better long-term clinical outcomes. Post-surgery CD recurrence can be suggested by early IUS assessment.
Collapse
Affiliation(s)
- Mirella Fraquelli
- Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Milan, Italy.
| | - Fabiana Castiglione
- Gastroenterology, Department of Clinical Medicine and Surgery, School of Medicine, "Federico II" University of Naples, Naples, Italy
| | - Emma Calabrese
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Giovanni Maconi
- Gastroenterology Unit, Department of Biomedical and Clinical Sciences, ASST Fatebenefratelli Sacco, "Luigi Sacco" Hospital, University of Milan, Italy
| |
Collapse
|
38
|
Sarno A, Varello S, Debani P, Bonenti G, Robotti D. Intestinal ultrasonography in adults with Crohn's disease: a 2020 update. MINERVA GASTROENTERO 2019; 65:335-345. [PMID: 31760739 DOI: 10.23736/s1121-421x.19.02638-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
In the last years intestinal ultrasonography (IUS) has increased its role in the management of inflammatory bowel diseases (IBD), that include Crohn's disease (CD) and ulcerative colitis. This is due to the fact that IUS is a non-invasive, inexpensive, and well-tolerated examination technique. Furthermore, it allows a real-time diagnosis with no radiation exposure. Usually, convex and linear probes with frequency between 3.5 and 12 MHz are used, also with the Color- Power Doppler. Focusing on CD, the IUS images of clinical interest are: bowel wall thickening (greater than 3 mm), pseudostratification and the wall vascularization. Moreover, IUS demonstrates inflammatory mass, loss of colonic haustration and the complications of the disease, such as stenosis, abscesses, and fistulas as well as other extraintestinal manifestations, such as lymph node enlargement and changes in the appearance of the mesenteric adipose tissue (creeping fat). Oral and intravenous contrast are used to obtain a better visualization of the bowel wall and to increase the diagnostic accuracy of IUS. In particular, intravenous contrast, administered during the procedure, allows to differentiate between active disease (bowel wall enhancement) and the fibrostenotic complications. Contrast-enhanced ultrasonography (CEUS) was proven to be useful in the follow-up and the disease recurrence detection. Beyond the support in the initial diagnosis, IUS has an important role in the follow-up of patients with CD, to monitor the response to the medical therapy and to detect possible complications. Furthermore, it can predict the recurrences after surgery, with more accuracy if Color-Doppler is used.
Collapse
Affiliation(s)
- Antonino Sarno
- Unit of Radiodiagnostics 2, AOU Città della Salute e della Scienza di Torino, Turin, Italy -
| | - Sara Varello
- Unit of Radiodiagnostics 2, AOU Città della Salute e della Scienza di Torino, Turin, Italy
| | - Paola Debani
- Unit of Radiodiagnostics 2, AOU Città della Salute e della Scienza di Torino, Turin, Italy
| | - Giovanni Bonenti
- Unit of Radiodiagnostics 2, AOU Città della Salute e della Scienza di Torino, Turin, Italy
| | - Daniela Robotti
- Unit of Radiodiagnostics 2, AOU Città della Salute e della Scienza di Torino, Turin, Italy
| |
Collapse
|
39
|
Allocca M, Fiorino G, Bonifacio C, Peyrin-Biroulet L, Danese S. Noninvasive Multimodal Methods to Differentiate Inflamed vs Fibrotic Strictures in Patients With Crohn's Disease. Clin Gastroenterol Hepatol 2019; 17:2397-2415. [PMID: 30995529 DOI: 10.1016/j.cgh.2019.04.025] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Revised: 04/08/2019] [Accepted: 04/10/2019] [Indexed: 02/07/2023]
Abstract
Fibrotic strictures occur in 30% of patients with Crohn's disease (CD). However, there are no therapeutic agents that prevent or reverse fibrotic strictures. Strictures are treated by endoscopic dilatation procedures and surgical procedures, but there are high rates of recurrence. Two antifibrotic agents (nintedanib and pirfenidone) recently were approved for the treatment of idiopathic pulmonary fibrosis and inhibitors of Rho-associated protein kinases 1 and 2 reversed fibrosis in mice with chronic intestinal inflammation. Cross-sectional imaging techniques, such as magnetic resonance (MR) enterography, computed tomography enterography, and bowel ultrasound, are used to assess small-bowel and CD-related complications, including strictures. It is important to be able to determine the degree of inflammation and fibrosis in strictures to select the best therapy; this can be a challenge because inflammation and fibrosis co-exist to varying degrees in a damaged bowel segment. Delayed gadolinium enhancement, magnetization transfer MR imaging, and ultrasound elastography seem to be promising tools for assessing fibrosis in patients with CD. We review noninvasive techniques for fibrosis assessment, including analyses of genetic, epigenetic, and protein markers. We discuss the potential of imaging techniques such as diffusion-weighted and magnetization transfer MR imaging, strain elastography, shear-wave imaging, and positron emission tomography to guide therapeutic decisions for patients with stricturing CD.
Collapse
Affiliation(s)
- Mariangela Allocca
- Inflammatory Bowel Disease Centre, Humanitas Clinical and Research Centre, Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, Rozzano, Milan, Italy
| | - Gionata Fiorino
- Inflammatory Bowel Disease Centre, Humanitas Clinical and Research Centre, Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, Rozzano, Milan, Italy
| | - Cristiana Bonifacio
- Division of Diagnostic Radiology, Humanitas Clinical and Research Centre, Rozzano, Milano, Italy
| | - Laurent Peyrin-Biroulet
- Department of Gastroenterology and Inserm U954, University Hospital of Nancy, Lorraine University, Nancy, France
| | - Silvio Danese
- Inflammatory Bowel Disease Centre, Humanitas Clinical and Research Centre, Rozzano, Milan, Italy; Department of Biomedical Sciences, Humanitas University, Rozzano, Milan, Italy.
| |
Collapse
|
40
|
Yaguchi K, Sasaki T, Ogashiwa T, Nishio M, Hashimoto Y, Ikeda A, Izumi M, Hanzawa A, Shibata N, Yonezawa H, Sakamaki K, Tateishi Y, Numata K, Maeda S, Kimura H, Kunisaki R. Correlation between the macroscopic severity of Crohn's disease in resected intestine and bowel wall thickness evaluated by water-immersion ultrasonography. Scand J Gastroenterol 2019; 54:1331-1338. [PMID: 31656106 DOI: 10.1080/00365521.2019.1683224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Objectives: Transabdominal ultrasonography is a common and accurate tool for managing Crohn's disease (CD); however, the significance of the resulting data is poorly understood. This study was performed to determine the association between bowel wall thickness evaluated by water-immersion ultrasonography and macroscopic severity, namely, refractory inflammation and subsequent fibrosis in CD surgical specimens.Materials and methods: We retrospectively evaluated 100 segments of colon and small intestine from 27 patients with CD. The resected specimens were placed in saline postoperatively, and bowel wall thickness was measured by water-immersion ultrasonography and compared with macroscopic findings. Correlations between bowel wall thickness and macroscopic findings were assessed using analysis of variance and receiver operating characteristic curves.Results: According to the progression of macroscopic severity, the mean bowel wall thickness was increased as follows: macroscopically intact: 4.1 mm, longitudinal ulcer scars: 5.4 mm, longitudinal open ulcers: 6.0 mm, large ulcers: 6.4 mm, cobblestone-like lesions: 7.1 mm, and fibrotic strictures: 7.4 mm. For all lesions except longitudinal ulcer scars, the bowel wall thickness was significantly thicker than that of macroscopically-intact areas (p < .001). According to receiver operating characteristic curves, bowel wall thickness >4.5 mm was associated with CD lesions, and thickness >5.5 mm was associated with more severe lesions.Conclusions: The bowel wall thickness of CD lesions was evaluated by water-immersion ultrasonography correlated with macroscopic disease severity.
Collapse
Affiliation(s)
- Katsuki Yaguchi
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan.,Department of Gastroenterology, Yokohama City University Graduate School of Medicine, Yokohama, Japan
| | - Tomohiko Sasaki
- Department of Gastroenterology, Yokohama City University Graduate School of Medicine, Yokohama, Japan
| | - Tsuyoshi Ogashiwa
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
| | - Masafumi Nishio
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
| | - Yu Hashimoto
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
| | - Aya Ikeda
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
| | - Misato Izumi
- Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama, Japan
| | - Akiho Hanzawa
- Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama, Japan
| | - Naomi Shibata
- Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama, Japan
| | - Hiromi Yonezawa
- Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama, Japan
| | - Kentaro Sakamaki
- Department of Biostatistics and Epidemiology, Graduate School of Medicine, Yokohama City University, Yokohama, Japan
| | - Yoko Tateishi
- Department of Pathology, Yokohama City University Graduate School of Medicine, Yokohama, Japan
| | - Kazushi Numata
- Gastroenterological Center, Yokohama City University Medical Center, Yokohama, Japan
| | - Shin Maeda
- Department of Gastroenterology, Yokohama City University Graduate School of Medicine, Yokohama, Japan
| | - Hideaki Kimura
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
| | - Reiko Kunisaki
- Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
| |
Collapse
|
41
|
Coy CSR, Kotze PG. SURGICAL STRATEGIES IN MULTIDISCIPLINARY MANAGEMENT OF CROHN'S DISEASE. REVISTA MÉDICA CLÍNICA LAS CONDES 2019. [DOI: 10.1016/j.rmclc.2019.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
42
|
Rao N, Kumar S, Taylor S, Plumb A. Diagnostic pathways in Crohn's disease. Clin Radiol 2019; 74:578-591. [PMID: 31005268 DOI: 10.1016/j.crad.2019.03.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 03/14/2019] [Indexed: 12/17/2022]
Abstract
The management of Crohn's disease (CD) is shifting from a stepwise, incremental approach based on symptom control to more aggressive early combined immunosuppression in an attempt to induce remission more rapidly and avoid long-term bowel damage. Accurately defining disease activity is a major challenge, as there is often a disconnect between symptomatology and underlying disease status. The role of imaging in CD has evolved such that it now plays a central role establishing the initial diagnosis, characterising disease phenotype, activity assessment, disease surveillance, and assessing response to therapy. Furthermore, the "treat-to-target" approach is being investigated in CD, with resolution of transmural inflammation on cross-sectional imaging being the treatment goal. In this review, we summarise the principal imaging techniques available to the radiologist, the key findings, and provide some guidance on the preferred imaging option in the diagnostic pathway. We consider the relative merits and drawbacks of each imaging technique before offering a brief discussion of some current developments and research avenues in CD imaging. We discuss how imaging may be useful in a "treat-to-target" approach. Finally, we highlight some practical considerations around service configuration and delivery to optimise imaging in CD in an accurate, cost-effective manner.
Collapse
Affiliation(s)
- N Rao
- Department of Radiology, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, UK
| | - S Kumar
- Centre for Medical Imaging, University College London, London, UK
| | - S Taylor
- Centre for Medical Imaging, University College London, London, UK
| | - A Plumb
- Centre for Medical Imaging, University College London, London, UK.
| |
Collapse
|
43
|
Omotehara S, Nishida M, Kinoshita K, Onishi R, Onodera A, Suya M, Hasegawa T, Mitsumori D, Katsurada T, Teshima T. Validation of US evaluation of ulcerative colitis activity. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1537-1544. [PMID: 30987912 DOI: 10.1016/j.ultrasmedbio.2019.02.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 02/23/2019] [Accepted: 02/26/2019] [Indexed: 06/09/2023]
Abstract
This study was aimed at validating the inter-rater grading agreement for assessing disease activity in patients with established ulcerative colitis (UC) using transabdominal ultrasonography (US) versus colonoscopy (CS). Fifty-seven patients underwent US and CS at four facilities. UC disease activity was assessed using the original US grading system and CS Matts classification. Initially, the US and CS grades were assessed at each examining facility, and still images and movie clips were re-assessed at the central facility. Grading agreement between the examining and central facilities was evaluated. Grading agreement for US and CS were 0.75 and 0.72 in all segments and 0.82 and 0.70 in the maximum grade of each patient, respectively (all p < 0.001). US grading agreement was "almost perfect" for the maximum grade and "moderate" to "substantial" for other assessments. The inter-rater US grading agreement was good and not inferior to that of CS for evaluating UC disease activity.
Collapse
Affiliation(s)
- Satomi Omotehara
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Kita-ku, Sapporo, Japan; Diagnostic Center for Sonography, Hokkaido University Hospital, Kita-ku, Sapporo, Japan
| | - Mutsumi Nishida
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Kita-ku, Sapporo, Japan; Diagnostic Center for Sonography, Hokkaido University Hospital, Kita-ku, Sapporo, Japan.
| | - Kenji Kinoshita
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Kita-ku, Sapporo, Japan
| | - Reizo Onishi
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Kita-ku, Sapporo, Japan
| | - Aki Onodera
- Department of Clinical Laboratory, Tomakomai City Hospital, Shimizutyou, Tomakomai, Japan
| | - Mitsuhisa Suya
- Department of Clinical Laboratory, Sapporo Higashi Tokushukai Hospital, Higashi-ku, Sapporo, Japan
| | - Toru Hasegawa
- Department of Clinical Laboratory, Ohguro Gastroenterological Hospital, Kita-ku, Sapporo, Japan
| | - Daiki Mitsumori
- Department of Clinical Laboratory, NTT East Japan Sapporo Hospital, Chuou-ku, Sapporo, Japan
| | - Takehiko Katsurada
- Division of Endoscopy, Hokkaido University Hospital, Kita-ku, Sapporo, Japan
| | - Takanori Teshima
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Kita-ku, Sapporo, Japan
| |
Collapse
|
44
|
Kinoshita K, Katsurada T, Nishida M, Omotehara S, Onishi R, Mabe K, Onodera A, Sato M, Eto K, Suya M, Maemoto A, Hasegawa T, Yamamoto J, Mitsumori D, Yoshii S, Ono K, Sakamoto N. Usefulness of transabdominal ultrasonography for assessing ulcerative colitis: a prospective, multicenter study. J Gastroenterol 2019; 54:521-529. [PMID: 30519747 DOI: 10.1007/s00535-018-01534-w] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 11/27/2018] [Indexed: 02/04/2023]
Abstract
BACKGROUND Transabdominal ultrasonography (US) has been reported to be a useful tool for evaluating ulcerative colitis (UC) although with less well-established data than for Crohn's disease. This prospective multicenter study aimed to establish the usefulness of US compared with colonoscopy (CS) for assessing disease extent and activity of UC. METHODS Altogether, 173 patients with UC were prospectively enrolled, among whom 156 were eligible for this study. All patients underwent US and CS within 2 days at five facilities. We divided the colon into six segments and examined each segment and the rectum using US and CS. US severity was graded 1-4 regarding bowel wall thickness, stratification, and ulceration. CS severity was also graded 1-4 according to Matts' endoscopic classification. Concordance between US and CS grades for all colonic segments was analyzed using kappa statistics. US and CS findings were also compared with the clinical disease activity index (CAI) and histological grade using Spearman's correlation coefficient. RESULTS There was moderate concordance between US and CS grades in all colonic segments (weighted κ = 0.55, p < 0.001). Concordance was rated moderate for each colonic segment but only slight for the rectum. The US grade was significantly correlated with the CAI score (r = 0.40, p < 0.001) and histological grade (r = 0.35, p < 0.001). CONCLUSIONS This prospective multicenter study showed moderate concordance between US and CS for assessing the disease activity of UC. Hence, US may be used more generally for evaluating UC in daily clinical practice.
Collapse
Affiliation(s)
- Kenji Kinoshita
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7 Kita-ku, Sapporo, 060-8638, Japan.
| | - Takehiko Katsurada
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7 Kita-ku, Sapporo, 060-8638, Japan
| | - Mutsumi Nishida
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Sapporo, Japan.,Diagnostic Center for Sonography, Hokkaido University Hospital, Sapporo, Japan
| | - Satomi Omotehara
- Division of Laboratory and Transfusion Medicine, Hokkaido University Hospital, Sapporo, Japan.,Diagnostic Center for Sonography, Hokkaido University Hospital, Sapporo, Japan
| | - Reizo Onishi
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7 Kita-ku, Sapporo, 060-8638, Japan
| | - Katsuhiro Mabe
- Department of Gastroenterology, National Hospital Organization Hakodate Hospital, Hakodate, Japan
| | - Aki Onodera
- Department of Clinical Laboratory, Tomakomai City Hospital, Tomakomai, Japan
| | - Mami Sato
- Department of Clinical Laboratory, Tomakomai City Hospital, Tomakomai, Japan
| | - Kazunori Eto
- Department of Gastroenterology, Tomakomai City Hospital, Tomakomai, Japan
| | - Mitsutoshi Suya
- Department of Clinical Laboratory, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Atsuo Maemoto
- Inflammatory Bowel Disease Center, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Toru Hasegawa
- Department of Clinical Laboratory, Ohguro Gastroenterological Hospital, Sapporo, Japan
| | | | - Daiki Mitsumori
- Department of Clinical Laboratory, Sapporo Medical Center NTT EC, Sapporo, Japan
| | - Shinji Yoshii
- Department of Gastroenterology, Sapporo Medical Center NTT EC, Sapporo, Japan
| | - Kota Ono
- Clinical Research and Medical Innovation Center, Hokkaido University Hospital, Sapporo, Japan
| | - Naoya Sakamoto
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7 Kita-ku, Sapporo, 060-8638, Japan
| |
Collapse
|
45
|
Intravenous Contrast-Enhanced Ultrasound for Assessing and Grading Postoperative Recurrence of Crohn's Disease. Dig Dis Sci 2019; 64:1640-1650. [PMID: 30604372 DOI: 10.1007/s10620-018-5432-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Accepted: 12/12/2018] [Indexed: 12/11/2022]
Abstract
PURPOSE The aim was to investigate the contribution of contrast-enhanced ultrasound (CEUS) to improve the results of US in the evaluation of recurrence in postsurgical Crohn's disease (CD) and establish its role in the assessment of the severity. METHODS Anastomotic site was assessed in 108 postsurgical CD patients with B-mode, color Doppler and CEUS. Bowel wall thickness (WT), transmural complications or stenosis, color Doppler grade, and bowel wall contrast enhancement (BWCE)-using time-intensity curves-were correlated with endoscopic Rutgeerts score. A receiver operating characteristic (ROC) curve was built to establish the best cutoff to predict recurrence and the severity. A US scoring system was elaborated in order to determine the grade of recurrence. RESULTS Ileocolonoscopy detected recurrence in 90 (83.3%) subjects and severe recurrence in 62. WT ≥ 3 mm had an accuracy of 90.7% in the detection of endoscopic recurrence. The combination of parameters-WT ≥ 3 mm and BWCE (≥ 46%)-demonstrated similar accuracy (90.7%). A WT ≥ 5 mm showed the best specificity (100%) for the diagnosis of recurrence and a WT ≥ 6 mm the best specificity (95.7%) for the detection of severe recurrence. The combination of sonographic parameters-WT ≥ 6 mm or WT between 5 and 6 mm with BWCE ≥ 70%, or complications-obtained the best results grading the recurrence (sensitivity, specificity, and accuracy of 90.3%, 87%, and 88.9%, respectively). CONCLUSIONS US shows high sensitivity and specificity for the diagnosis of postsurgical recurrence. When combined with CEUS, it can improve the detection of severe recurrence.
Collapse
|
46
|
Sturm A, Maaser C, Calabrese E, Annese V, Fiorino G, Kucharzik T, Vavricka SR, Verstockt B, van Rheenen P, Tolan D, Taylor SA, Rimola J, Rieder F, Limdi JK, Laghi A, Krustiņš E, Kotze PG, Kopylov U, Katsanos K, Halligan S, Gordon H, González Lama Y, Ellul P, Eliakim R, Castiglione F, Burisch J, Borralho Nunes P, Bettenworth D, Baumgart DC, Stoker J. ECCO-ESGAR Guideline for Diagnostic Assessment in IBD Part 2: IBD scores and general principles and technical aspects. J Crohns Colitis 2019; 13:273-284. [PMID: 30137278 DOI: 10.1093/ecco-jcc/jjy114] [Citation(s) in RCA: 281] [Impact Index Per Article: 46.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Andreas Sturm
- Department of Gastroenterology, DRK Kliniken Berlin I Westend, Berlin, Germany
| | - Christian Maaser
- Outpatients Department of Gastroenterology, Hospital Lüneburg, Lüneburg, Germany
| | - Emma Calabrese
- Department of Systems Medicine, University of Rome, Tor Vergata, Italy
| | - Vito Annese
- Department of Gastroenterology, Valiant Clinic & American Hospital, Dubai, UAE
| | - Gionata Fiorino
- Department of Gastroenterology, Humanitas Clinical and Research Institute, Milan, Italy
| | - Torsten Kucharzik
- Department of Internal Medicine and Gastroenterology, Hospital Lüneburg, Lüneburg, Germany
| | | | - Bram Verstockt
- Department of Gastroenterology and Hepatology, University Hospitals Leuven and CHROMETA - Translational Research in Gastrointestinal Disorders, KU Leuven, Belgium
| | - Patrick van Rheenen
- Department of Paediatric Gastroenterology, Hepatology and Nutrition, University Medical Center Groningen, Groningen, The Netherlands
| | - Damian Tolan
- Clinical Radiology, St James's University Hospital, Leeds, UK
| | - Stuart A Taylor
- Centre for Medical Imaging, University College London, London, UK
| | - Jordi Rimola
- Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain
| | - Florian Rieder
- Department of Gastroenterology, Hepatology & Nutrition, Digestive Diseases and Surgery Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Jimmy K Limdi
- Department of Gastroenterology, Pennine Acute Hospitals NHS Trust, Manchester; Manchester Academic Health Sciences Centre, University of Manchester, Manchester, UK
| | - Andrea Laghi
- Department of Clinical and Surgical Translational Medicine, Sapienza - University of Rome, Rome, Italy
| | - Eduards Krustiņš
- Department of Gastroenterology, Hepatology and Nutrition, Pauls Stradins Clinical University Hospital, Riga, Latvia
| | - Paulo G Kotze
- Colorectal Surgery Unit, Catholic University of Paraná PUCPR, Curitiba, Brazil
| | - Uri Kopylov
- Department of Gastroenterology, Sheba Medical Center, Sackler School of Medicine, Tel Aviv, Israel
| | - Konstantinos Katsanos
- Department of Gastroenterology and Hepatology, University and Medical School of Ioannina, Ioannina, Greece
| | - Steve Halligan
- Centre for Medical Imaging, University College London, London, UK
| | - Hannah Gordon
- Section of Gastroenterology & Hepatology, Royal London Hospital, London, UK
| | - Yago González Lama
- Department of Gastroenterology, University Hospital Puerta De Hierro, Majadahonda Madrid, Spain
| | - Pierre Ellul
- Department of Medicine, Mater Dei Hospital, Msida, Malta
| | - Rami Eliakim
- Department of Gastroenterology, Sheba Medical Center, Sackler School of Medicine, Tel Aviv, Israel
| | - Fabiana Castiglione
- Department of Clinical Medicine and Surgery, "Federico II" University of Naples, Naples, Italy
| | - Johan Burisch
- Department of Gastroenterology, North Zealand University Hospital; Center for Clinical Research and Prevention, Bispebjerg and Frederiksberg Hospital, Frederiksberg, Denmark
| | - Paula Borralho Nunes
- Department of Anatomic Pathology, Hospital Cuf Descobertas; Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal
| | - Dominik Bettenworth
- Department of Medicine B, Gastroenterology and Hepatology, University Hospital Münster, Münster, Germany
| | - Daniel C Baumgart
- Division of Gastroenterology, University of Alberta, Edmonton, AB, Canada
| | - Jaap Stoker
- Department of Radiology and Nuclear Medicine, Academic Medical Center AMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
47
|
Lu C, Merrill C, Medellin A, Novak K, Wilson SR. Bowel Ultrasound State of the Art: Grayscale and Doppler Ultrasound, Contrast Enhancement, and Elastography in Crohn Disease. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:271-288. [PMID: 30604884 DOI: 10.1002/jum.14920] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 11/08/2018] [Accepted: 11/22/2018] [Indexed: 06/09/2023]
Abstract
Bowel ultrasound (US) is accurate for assessing bowel inflammation and complications in Crohn disease. Additionally, contrast-enhanced US provides a quantitative, objective measurement of inflammatory activity in inflammatory bowel disease, and shear wave elastography predicts the stiffness of bowel, an increase of which suggests less response to medical therapy, often necessitating surgery. Overall, bowel US is an excellent, safe, and repeatable choice for routine surveillance and for urgent imaging. We describe an approach to evaluating inflammatory bowel disease and review its features on standard grayscale US with Doppler imaging and show how contrast-enhanced US and shear wave elastography can distinguish between inflammatory and fibrostenotic bowel.
Collapse
Affiliation(s)
- Cathy Lu
- Department of Medicine, Division of Gastroenterology, University of Calgary, Calgary, Alberta, Canada
| | - Christina Merrill
- Department of Radiology, University of Calgary, Calgary, Alberta, Canada
| | - Alexandra Medellin
- Department of Radiology, University of Calgary, Calgary, Alberta, Canada
| | - Kerri Novak
- Department of Medicine, Division of Gastroenterology, University of Calgary, Calgary, Alberta, Canada
| | - Stephanie R Wilson
- Department of Medicine, Division of Gastroenterology, University of Calgary, Calgary, Alberta, Canada
- Department of Radiology, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
48
|
Calabrese E, Kucharzik T, Maaser C, Maconi G, Strobel D, Wilson SR, Zorzi F, Novak KL, Bruining DH, Iacucci M, Watanabe M, Lolli E, Chiaramonte C, Hanauer SB, Panaccione R, Pallone F, Ghosh S, Monteleone G. Real-time Interobserver Agreement in Bowel Ultrasonography for Diagnostic Assessment in Patients With Crohn's Disease: An International Multicenter Study. Inflamm Bowel Dis 2018; 24:2001-2006. [PMID: 29718450 DOI: 10.1093/ibd/izy091] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Indexed: 12/27/2022]
Abstract
BACKGROUND The unavailability of standardized parameters in bowel ultrasonography (US) commonly used in Crohn's disease (CD) and the shortage of skilled ultrasonographers are 2 limiting factors in the use of this imaging modality around the world. The aim of this study is to evaluate interobserver agreement among experienced sonographers in the evaluation of bowel US parameters in order to improve standardization in imaging reporting and interpretation. METHODS Fifteen patients with an established diagnosis of CD underwent blinded bowel US performed by 6 experienced sonographers. Prior to the evaluation, the sonographers and clinical and radiological IBD experts met to formally define the US parameters. Interobserver agreement was tested with the Quatto method (s). RESULTS All operators agreed on the presence/absence of CD lesions and distinguished absence of/mild activity or moderate/severe lesions in all patients. S values were moderate for bowel wall thickness (s = 0.48, P = n.s.), bowel wall pattern (s = 0.41, P = n.s.), vascularization (s = 0.52, P = n.s.), and presence of lymphnodes (s = 0.61, P = n.s.). Agreement was substantial for lesion location (s = 0.68, P = n.s.), fistula (s = 0.74, P = n.s.), phlegmon (s = 0.78, P = 0.04), and was almost perfect for abscess (s = 0.95, P = 0.02). Poor agreement was observed for mesenteric adipose tissue alteration, lesion extent, stenosis, and prestenotic dilation. CONCLUSIONS In this study, the majority of the US parameters used in CD showed moderate/substantial agreement. The development of shared US imaging interpretation patterns among sonographers will lead to improved comparability of US results among centers and facilitate the development of multicenter studies and the spread of bowel US training, thereby allowing a wider adoption of this useful technique.
Collapse
Affiliation(s)
- Emma Calabrese
- Gastroenterology Unit, Department of Systems Medicine, University of Rome "Tor Vergata," Italy
| | - Torsten Kucharzik
- Department of Internal Medicine and Gastroenterology, Staedtisches Klinikum Lueneburg, Lueneburg, Germany
| | - Christian Maaser
- Ambulanzzentrum Gastroenterologie am Klinikum Lüneburg, Lüneburg, Germany
| | - Giovanni Maconi
- Department of Clinical Sciences, L. Sacco University Hospital, Milan, Italy
| | | | - Stephanie R Wilson
- Department of Radiology and **Division of Gastroenterology, Department of Medicine, University of Calgary, Calgary, Canada.,Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Francesca Zorzi
- Gastroenterology Unit, Department of Systems Medicine, University of Rome "Tor Vergata," Italy
| | - Kerri L Novak
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - David H Bruining
- Department of Gastroenterology and Hepatology, Tokyo Medical and Dental University, Japan
| | - Marietta Iacucci
- Institute of Translational of Medicine, University of Birmingham, Birmingham, UK
| | - Mamoru Watanabe
- Northwestern University Feinberg School of Medicine, Digestive Disease Center, Chicago, Illinois, USA
| | - Elisabetta Lolli
- Gastroenterology Unit, Department of Systems Medicine, University of Rome "Tor Vergata," Italy
| | - Carlo Chiaramonte
- Gastroenterology Unit, Department of Systems Medicine, University of Rome "Tor Vergata," Italy
| | - Stephen B Hanauer
- Northwestern University Feinberg School of Medicine, Digestive Disease Center, Chicago, Illinois, USA
| | - Remo Panaccione
- Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Francesco Pallone
- Gastroenterology Unit, Department of Systems Medicine, University of Rome "Tor Vergata," Italy
| | - Subrata Ghosh
- Institute of Translational of Medicine, University of Birmingham, Birmingham, UK
| | - Giovanni Monteleone
- Gastroenterology Unit, Department of Systems Medicine, University of Rome "Tor Vergata," Italy
| |
Collapse
|
49
|
Taylor SA, Mallett S, Bhatnagar G, Baldwin-Cleland R, Bloom S, Gupta A, Hamlin PJ, Hart AL, Higginson A, Jacobs I, McCartney S, Miles A, Murray CD, Plumb AA, Pollok RC, Punwani S, Quinn L, Rodriguez-Justo M, Shabir Z, Slater A, Tolan D, Travis S, Windsor A, Wylie P, Zealley I, Halligan S. Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial. Lancet Gastroenterol Hepatol 2018; 3:548-558. [PMID: 29914843 PMCID: PMC6278907 DOI: 10.1016/s2468-1253(18)30161-4] [Citation(s) in RCA: 167] [Impact Index Per Article: 23.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 04/23/2018] [Accepted: 04/24/2018] [Indexed: 02/09/2023]
Abstract
BACKGROUND Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. FINDINGS 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. INTERPRETATION Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. FUNDING National Institute of Health and Research Health Technology Assessment.
Collapse
Affiliation(s)
- Stuart A Taylor
- Centre for Medical Imaging, University College London (UCL), London, UK.
| | - Susan Mallett
- Institute of Applied Health Research, National Institute of Health and Research Birmingham Biomedical Research Centre, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | | | - Rachel Baldwin-Cleland
- Intestinal Imaging Centre, St Mark's Hospital, London North West University Healthcare (LNWUH) National Health Service (NHS) Trust, Harrow, UK
| | - Stuart Bloom
- Department of Gastroenterology, University College Hospital, London, UK
| | - Arun Gupta
- Intestinal Imaging Centre, St Mark's Hospital, London North West University Healthcare (LNWUH) National Health Service (NHS) Trust, Harrow, UK
| | - Peter J Hamlin
- Department of Gastroenterology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Ailsa L Hart
- Inflammatory Bowel Disease Unit, St Mark's Hospital, LNWUH NHS Trust, Harrow, UK
| | - Antony Higginson
- Department of Radiology, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | | | - Sara McCartney
- Department of Gastroenterology, University College Hospital, London, UK
| | - Anne Miles
- Department of Psychological Sciences, Birkbeck University of London, London, UK
| | - Charles D Murray
- Department of Gastroenterology and Endoscopy, Royal Free London NHS Foundation Trust, London, UK
| | - Andrew A Plumb
- Centre for Medical Imaging, University College London (UCL), London, UK
| | - Richard C Pollok
- Department of Gastroenterology, St George's Hospital, London, UK
| | - Shonit Punwani
- Centre for Medical Imaging, University College London (UCL), London, UK
| | - Laura Quinn
- Institute of Applied Health Research, National Institute of Health and Research Birmingham Biomedical Research Centre, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK
| | | | - Zainib Shabir
- Comprehensive Clinical Trials Unit at UCL, Institute of Clinical Trials and Methodology, Holborn, London, UK
| | - Andrew Slater
- Department of Radiology, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Damian Tolan
- Department of Radiology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Simon Travis
- Translational Gastroenterology Unit, Oxford University Hospitals, Oxford, UK
| | | | - Peter Wylie
- Department of Radiology, Royal Free London NHS Foundation Trust, London, UK
| | - Ian Zealley
- Department of Radiology, Ninewells Hospital, Dundee, UK
| | - Steve Halligan
- Centre for Medical Imaging, University College London (UCL), London, UK
| |
Collapse
|
50
|
Rispo A, Imperatore N, Testa A, Bucci L, Luglio G, De Palma GD, Rea M, Nardone OM, Caporaso N, Castiglione F. Combined Endoscopic/Sonographic-based Risk Matrix Model for Predicting One-year Risk of Surgery: A Prospective Observational Study of a Tertiary Centre Severe/Refractory Crohn's Disease Cohort. J Crohns Colitis 2018; 12:784-793. [PMID: 29528382 DOI: 10.1093/ecco-jcc/jjy032] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Accepted: 03/06/2018] [Indexed: 12/17/2022]
Abstract
BACKGROUND In the management of Crohn's disease [CD] patients, having a simple score combining clinical, endoscopic, and imaging features to predict the risk of surgery could help to tailor treatment more effectively. AIMS We aimed to prospectively evaluate the 1-year risk factors for surgery in refractory/severe CD and to generate a risk matrix for predicting the probability of surgery at 1 year. METHODS CD patients needing a disease re-assessment at our tertiary inflammatory bowel disease [IBD] centre underwent clinical, laboratory, endoscopic, and bowel sonography [BS] examinations within 1 week. The optimal cut-off values in predicting surgery were identified using receiver operating characteristic [ROC] curves for the Simple Endoscopic Score for CD [SES-CD], bowel wall thickness [BWT] at BS, and small bowel CD extension at BS. Binary logistic regression and Cox regression were then carried out. Finally, the probabilities of surgery were calculated for selected baseline levels of covariates and results were arranged in a prediction matrix. RESULTS Of 100 CD patients, 30 underwent surgery within 1 year. SES-CD ≥9 (odds ratio [OR] 15.3; p <0.001], BWT ≥7 mm [OR 15.8; p <0.001], small bowel CD extension at BS ≥33 cm [OR 8.23; p <0.001], and stricturing/penetrating behaviour [OR 4.3; p <0.001] were the only independent factors predictive of surgery at 1 year, based on binary logistic and Cox regressions. Our matrix model combined these risk factors, and the probability of surgery ranged from 0.48% to 87.5% [16 combinations]. CONCLUSIONS Our risk matrix combining clinical, endoscopic, and ultrasonographic findings can accurately predict the 1-year risk of surgery in patients with severe/refractory CD requiring a disease re-evaluation. This tool could be of value in clinical practice, serving as the basis for a tailored management of CD patients.
Collapse
Affiliation(s)
- Antonio Rispo
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Nicola Imperatore
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Anna Testa
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Luigi Bucci
- Colorectal Surgery, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Gaetano Luglio
- Colorectal Surgery, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Giovanni Domenico De Palma
- Surgery and Advanced Technologies, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Italy
| | - Matilde Rea
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Olga Maria Nardone
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Nicola Caporaso
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| | - Fabiana Castiglione
- Gastroenterology, Department of Clinical Medicine and Surgery, 'Federico II' School of Medicine, Naples, Ital
| |
Collapse
|