• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4598436)   Today's Articles (4055)   Subscriber (49356)
For: Chica U, Flórez G, Anguiano M, Lallena A. A simple analytical expression to calculate the backscatter factor for low energy X-ray beams. Phys Med 2011;27:75-80. [DOI: 10.1016/j.ejmp.2010.03.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2009] [Revised: 01/19/2010] [Accepted: 03/31/2010] [Indexed: 10/19/2022]  Open
Number Cited by Other Article(s)
1
Tanabe R, Araki F. Determination of backscatter factors based on the quality index for diagnostic kilovoltage x-ray beams. Phys Med 2020;77:48-53. [DOI: 10.1016/j.ejmp.2020.07.032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/25/2020] [Accepted: 07/28/2020] [Indexed: 10/23/2022]  Open
2
Hill R, Healy B, Butler D, Odgers D, Gill S, Lye J, Gorjiara T, Pope D, Hill B. Australasian recommendations for quality assurance in kilovoltage radiation therapy from the Kilovoltage Dosimetry Working Group of the Australasian College of Physical Scientists and Engineers in Medicine. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2018;41:781-808. [DOI: 10.1007/s13246-018-0692-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
3
Poirier Y, Johnstone CD, Kirkby C. The potential impact of ultrathin filter design on dosimetry and relative biological effectiveness in modern image-guided small animal irradiators. Br J Radiol 2018;92:20180537. [PMID: 30281330 DOI: 10.1259/bjr.20180537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]  Open
4
Poirier Y, Kuznetsova S, Villarreal-Barajas JE. Characterization of nanoDot optically stimulated luminescence detectors and high-sensitivity MCP-N thermoluminescent detectors in the 40-300 kVp energy range. Med Phys 2017;45:402-413. [DOI: 10.1002/mp.12691] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 10/10/2017] [Accepted: 10/27/2017] [Indexed: 01/04/2023]  Open
5
Reynoso FJ, Tailor R, Wang CKC, Cho SH. Comparison of filtered x-ray spectra and depth doses derived from a hybrid Monte Carlo model of an orthovoltage x-ray unit with experimental measurements. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/4/045011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
6
Erazo F, Lallena AM. Photon beam quality correction factors for the NE2571A and NE2581A thimble ionization chambers using PENELOPE. Phys Med 2016;32:232-6. [DOI: 10.1016/j.ejmp.2015.09.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 09/03/2015] [Accepted: 09/28/2015] [Indexed: 10/22/2022]  Open
7
Eaton DJ, Doolan PJ. Review of backscatter measurement in kilovoltage radiotherapy using novel detectors and reduction from lack of underlying scattering material. J Appl Clin Med Phys 2013;14:4358. [PMID: 24257277 PMCID: PMC5714622 DOI: 10.1120/jacmp.v14i6.4358] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2013] [Revised: 06/18/2013] [Accepted: 06/11/2013] [Indexed: 11/23/2022]  Open
8
Chica U, Anguiano M, Lallena A. On the behavior of fc,Q factors with quality indexes for medium energy X-ray beams: A Monte Carlo study with penelope. Radiat Phys Chem Oxf Engl 1993 2013. [DOI: 10.1016/j.radphyschem.2013.03.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA