Momeni Harzanji Z, Larizadeh MH, Namiranian N, Nickfarjam A. Evaluation and Comparison of Dosimetric Characteristics of Semiflex ®3D and Microdiamond in Relative Dosimetry under 6 and 15 MV Photon Beams in Small Fields. J Biomed Phys Eng 2022; 12:477-488. [PMID: 36313410 PMCID: PMC9589081 DOI: 10.31661/jbpe.v0i0.2008-1160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 01/14/2021] [Indexed: 06/16/2023]
Abstract
BACKGROUND In modern radiotherapy techniques, the frequently small and non-uniformed fields can increase treatment efficiency due to their highly conformal dose distribution. Particular features including lack of Lateral Charge Particle Equilibrium (LCPE) lead to detectors with high resolution since any error in obtained dosimetric data could cause patient mistreatments. OBJECTIVE This study aims to evaluate and compare two small detectors (Semiflex®3D and microdiamond) dosimetric characteristics in small field relative dosimetry. MATERIAL AND METHODS In this experimental study, the dosimetric properties of Semiflex®3D and microdiamond were assessed under 6 and 15 MV photon beams. The linearity and stability of the detector's response and dose rate were measured. Square-field sizes ranging from 0.6×0.6 - 5×5 cm2 were used for obtaining percentage depth dose curves (PDDs) and in-plane profiles. The angular and temperature dependence of both detectors' responses were also studied. RESULTS The detector response shows good stability, no deviation from linearity, and low dose rate dependence (≤1.6%). PDDs and in-plan profiles of both detectors are in good agreement and no significant difference was observed except for the high dose gradient regions (P-value≤0.017). Both detectors demonstrated low angular dependence (<0.3%) with temperature dependence lower than 1% for both detectors. CONCLUSION The results indicate both investigated detectors were well performed in small field relative dosimetry and for measuring penumbra, it is better to use microdiamond detector.
Collapse
Affiliation(s)
- Zahra Momeni Harzanji
- MSc, Department of Medical Physics, School of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Mohammad Hassan Larizadeh
- MD, Department of Radiation Oncology, School of Medicine, Kerman University of Medical Sciences, Kerman, Iran
| | - Nasim Namiranian
- MD, Yazd Diabetes Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Abolfazl Nickfarjam
- PhD, Department of Medical Physics, School of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| |
Collapse
|
2
|
Parveen N, Ramachandran P, Seshadri V, Perrett B, Fielding A. Comparison and Validation of Multiple Detectors against Monte Carlo Simulation for the Use of Small-Field Dosimetry. J Med Phys 2022; 47:235-242. [PMID: 36684698 PMCID: PMC9847003 DOI: 10.4103/jmp.jmp_35_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 06/30/2022] [Accepted: 07/20/2022] [Indexed: 11/11/2022] Open
Abstract
Aim The aim of this study was to compare the Exradin W2 scintillator, PTW microDiamond, IBA Razor Nano, and IBA Razor chamber detectors for small-field dose measurements and validate the measured data against the EGSnrc user code and observe the variation between daisy-chained and direct measurement methods for the above detectors. Materials and Methods The W2 scintillator, microDiamond, Razor Nano, and Razor chamber detectors were used to measure the in-plane and cross-plane profiles and the output factors (OFs) at 10 cm depth, and 90 source-to-surface distance for 6MV X-rays (Elekta Versa HD). The field sizes ranged from 0.5 cm × 0.5 cm to 5 cm × 5 cm. The BEAMnrc/DOSXYZnrc user codes (EGSnrc) were used to simulate the reference profiles. Gamma analysis was performed to compare the measured and simulated dose distributions. Results The OFs measured with the W2 scintillator, microDiamond, Razor Nano chamber, Razor chamber, and the calculated Monte Carlo (MC) showed agreement to within 1% for the 3 cm × 3 cm field size. The uncertainty in the MC simulation was observed to be 0.4%. The percent difference in OFs measured using daisy-chained and direct measurement methods was within 0.15%, 0.4%, 1.4%, and 2.4% for microDiamond, W2 scintillator, Nano, and Razor chamber detectors, respectively. Conclusion The lateral beam profiles and OFs of W2 scintillator, microDiamond, Razor Nano, and Razor chambers exhibit good agreement with the MC simulation within the nominal field sizes. Our results demonstrate that we can achieve considerable time-saving by directly measuring small-field OFs without daisy-chained methods using microDiamond and W2 scintillator. In terms of ease of use, sensitivity, reproducibility, and from a practical standpoint, we recommend microDiamond for small-field dosimetry.
Collapse
Affiliation(s)
- Nazia Parveen
- Therapeutic Physics, Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia
| | - Prabhakar Ramachandran
- Therapeutic Physics, Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia
| | - Venkatakrishnan Seshadri
- Therapeutic Physics, Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia
| | - Ben Perrett
- Therapeutic Physics, Radiation Oncology, Cancer Services, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia
| | - Andrew Fielding
- School of Chemistry and Physics, Queensland University of Technology (QUT), Brisbane, Australia
| |
Collapse
|
3
|
López-Sánchez M, Pérez-Fernández M, Pardo E, Fandiño JM, Teijeiro A, Gómez-Fernández N, Gómez F, González-Castaño DM. Small static radiosurgery field dosimetry with small volume ionization chambers. Phys Med 2022; 97:66-72. [DOI: 10.1016/j.ejmp.2022.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 03/15/2022] [Accepted: 04/09/2022] [Indexed: 11/28/2022] Open
|
4
|
Falco MD, Fusella M, Clemente S, Fiandra C, Gallio E, Garibaldi C, Bagalà P, Borzì G, Casale M, Casati M, Consorti R, Delana A, Esposito M, Malatesta T, Menghi E, Reggiori G, Russo S, Stasi M, Mancosu P. The influence of basic plan parameters on calculated small field output factors - A multicenter study. Phys Med 2021; 88:98-103. [PMID: 34217003 DOI: 10.1016/j.ejmp.2021.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 06/02/2021] [Accepted: 06/04/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE The influence of basic plan parameters such as slice thickness, grid resolution, algorithm type and field size on calculated small field output factors (OFs) was evaluated in a multicentric study. METHODS AND MATERIALS Three computational homogeneous water phantoms with slice thicknesses (ST) 1, 2 and 3 mm were shared among twenty-one centers to calculate OFs for 1x1, 2x2 and 3x3 cm2 field sizes (FSs) (normalized to 10x10 cm2 FS), with their own treatment planning system (TPS) and the energy clinically used for stereotactic body radiation therapy delivery. OFs were calculated for each combination of grid resolution (GR) (1, 2 and 3 mm) and ST and finally compared with the OFs measured for the TPS commissioning. A multivariate analysis was performed to test the effect of basic plan parameters on calculated OFs. RESULTS A total of 509 data points were collected. Calculated OFs are slightly higher than measured ones. The multivariate analysis showed that Center, GR, algorithm type, and FS are predictive variables of the difference between calculated and measured OFs (p < 0.001). As FS decreases, the spread in the difference between calculated and measured OFs became larger when increasing the GR. Monte Carlo and Analytical Anisotropic Algorithms, presented a dependence on GR (p < 0.01), while Collapsed Cone Convolution and Acuros did not. The effect of the ST was found to be negligible. CONCLUSIONS Modern TPSs slightly overestimate the calculated small field OFs compared with measured ones. Grid resolution, algorithm, center number and field size influence the calculation of small field OFs.
Collapse
Affiliation(s)
- Maria Daniela Falco
- Department of Radiation Oncology, "G. D'Annunzio" University, "SS. Annunziata" Hospital, Chieti, Italy
| | - Marco Fusella
- Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, Padova, Italy
| | - Stefania Clemente
- Unit of Medical Physic and Radioprotection. Azienda Ospedaliera Universitaria Federico II, Naples, Italy
| | - Christian Fiandra
- Department of Oncology - Radiation Oncology, University of Turin, Turin, Italy
| | - Elena Gallio
- Department of Oncology - Radiation Oncology, University of Turin, Turin, Italy
| | - Cristina Garibaldi
- IEO, European Institute of Oncology IRCCS, Unit of Radiation Research, Milan, Italy
| | - Paolo Bagalà
- Universita' Campus Bio-medico di Roma, Via Alvaro del Portillo, 200 Rome, Italy
| | | | - Michelina Casale
- Struttura Semplice di Fisica Sanitaria Azienda Ospedaliera "Santa Maria" Terni, Italy
| | - Marta Casati
- MedicalPhysics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Rita Consorti
- Medical Physics Unit, S. Filippo Neri Hospital, ASL Roma 1, Rome, Italy
| | - Anna Delana
- Servizio di Fisica Sanitaria Ospedale S. Chiara A.P.S.S. Trento, Italy
| | - Marco Esposito
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - Tiziana Malatesta
- Fisica Medica, Ospedale Fatebenefratelli S.Giovanni Calibita- Rome, Italy
| | - Enrico Menghi
- Medical Physics Unit, Istituto Romagnolo per lo Studio dei Tumori "Dino Amadori" - IRST S.r.l.Istituto di Ricovero e Cura a Carattere Scientifico, Meldola (FC), Italy
| | - Giacomo Reggiori
- Medical Physics Unit of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Rozzano-Milan, Italy
| | - Serenella Russo
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy.
| | - Michele Stasi
- Medical Physics Department, A.O. Ordine Mauriziano, Turin, Italy
| | - Pietro Mancosu
- Medical Physics Unit of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Rozzano-Milan, Italy
| |
Collapse
|
5
|
Mancosu P, Russo S, Antonucci AR, Stasi M. Lean Thinking to manage a national working group on physics aspects of Stereotactic Body Radiation Therapy. Med Phys 2021; 48:2050-2056. [PMID: 33598932 DOI: 10.1002/mp.14783] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 01/21/2021] [Accepted: 02/09/2021] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To report how the adoption of a Lean Thinking mindset in the management of a national working group (WG) on the physics of stereotactic body radiation therapy (SBRT) contributed to achieve SBRT standardization objectives. METHODS Vision for the WG has been established as fragmentation reduction and process harmonization enhancement in SBRT for Italian centers. Two main research themes of the technical aspects of SBRT emerged as areas with major standardization improvement needs, small field dosimetry and SBRT planning comparisons, to be investigated through multi-institutional studies. The management of the WG leveraged on the Lean concept of fostering self-organization in a non-hierarchical environment. Four progressive involvement levels were defined for each study. No specific "scientific" pre-experience was required to propose and coordinate a project, just requiring a voluntary commitment. People engagement was measured in terms of number of published articles. The standardization goals have been conducted through a simplified "5S" (Sort, Set in Order, Shine, Standardize, and Sustain) methodology, first considering a phase of awareness (the first three "S"), then identifying and implementing standardization actions (the last two "S"). RESULTS Since the beginning, 157 medical physicists joined the AIFM/SBRT-WG. Twenty-four papers/reviews/letters have been published in the period 2014-2019 on major radiation oncology journals, authored by >100 physicists (>50% working in small hospitals). Six over 12 first authors worked in peripheral/small hospitals, with no prior publication as first author. These studies contributed to the awareness and standardization phases for both small-field dosimetry and planning. In particular, errors in small-field measurements in 8% of centers were detected thanks to a generalized output factor curve in function of the effective field size created by averaging data available from different Linacs. Furthermore, planner's experience in SBRT was correlated with dosimetric parameters in the awareness phase; while sharing median dose volume histograms (DVHs) reduced variability among centers while keeping the same level of plan complexity. Finally, all the dosimetric parameters statistically significant to the planner experience during the awareness phase, were no longer significantly different in the standardization phase. CONCLUSIONS The experience of our SBRT-WG has shown how a Lean Thinking mindset could foster the SBRT procedure standardization and spread the physics of SBRT knowledge, enhancing personal growth. Our expectation is to inspire other scientific societies that have to deal with fragmented contexts or pursue processes harmonization through Lean principles.
Collapse
Affiliation(s)
- Pietro Mancosu
- Medical Physics Unit, Radiotherapy Department, IRCCS Humanitas Research Hospital, Milano, Italy
| | - Serenella Russo
- Medical Physics Unit, Azienda USL Toscana Centro, Firenze, Italy
| | | | - Michele Stasi
- Medical Physics Department, A.O. Ordine Mauriziano di Torino, Turin, Italy
| |
Collapse
|
6
|
Clemente S, Falco MD, Cagni E, Talamonti C, Boccia M, Gino E, Lorenzini E, Rosica F, Russo S, Alparone A, Zefiro D, Fiandra C. The influence of small field output factors simulated uncertainties on the calculated dose in VMAT plans for brain metastases: a multicentre study. Br J Radiol 2021; 94:20201354. [PMID: 33481637 DOI: 10.1259/bjr.20201354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES This multicentric study was carried out to investigate the impact of small field output factors (OFs) inaccuracies on the calculated dose in volumetric arctherapy (VMAT) radiosurgery brain plans. METHODS Nine centres, realised the same five VMAT plans with common planning rules and their specific clinical equipment Linac/treatment planning system commissioned with their OFs measured values (OFbaseline). In order to simulate OFs errors, two new OFs sets were generated for each centre by changing only the OFs values of the smallest field sizes (from 3.2 × 3.2 cm2 to 1 × 1 cm2) with well-defined amounts (positive and negative). Consequently, two virtual machines for each centre were recommissioned using the new OFs and the percentage dose differences ΔD (%) between the baseline plans and the same plans recalculated using the incremented (OFup) and decremented (OFdown) values were evaluated. The ΔD (%) were analysed in terms of planning target volume (PTV) coverage and organs at risk (OARs) sparing at selected dose/volume points. RESULTS The plans recalculated with OFdown sets resulted in higher variation of doses than baseline within 1.6 and 3.4% to PTVs and OARs respectively; while the plans with OFup sets resulted in lower variation within 1.3% to both PTVs and OARs. Our analysis highlights that OFs variations affect calculated dose depending on the algorithm and on the delivery mode (field jaw/MLC-defined). The Monte Carlo (MC) algorithm resulted significantly more sensitive to OFs variations than all of the other algorithms. CONCLUSION The aim of our study was to evaluate how small fields OFs inaccuracies can affect the dose calculation in VMAT brain radiosurgery treatments plans. It was observed that simulated OFs errors, return dosimetric calculation accuracies within the 3% between concurrent plans analysed in terms of percentage dose differences at selected dose/volume points of the PTV coverage and OARs sparing. ADVANCES IN KNOWLEDGE First multicentre study involving different Planning/Linacs about undetectable errors in commissioning output factor for small fields.
Collapse
Affiliation(s)
- Stefania Clemente
- Unit of Medical Physics and Radioprotection, Federico II University Hospital, Napoli, Italy
| | - Maria Daniela Falco
- Department of Radiation Oncology, "G. D'Annunzio" University, "SS. Annunziata" Hospital, Chieti, Italy
| | - Elisabetta Cagni
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Cinzia Talamonti
- Medical Physics Unit, University Of Florence, Azienda Ospedaliero Universitaria Careggi, Florence, Italy
| | | | - Eva Gino
- Medical PhysicDepartment, A.O. Ordine Mauriziano, Turin, Italy
| | - Elena Lorenzini
- U.O.C Fisica Sanitaria Area Nord, Azienda USL Nord Ovest Toscana, Massa Carrara, Italy
| | | | | | | | - Daniele Zefiro
- MedicaPhysics Unit, ASL5 Sistema Sanitario Regione Liguria, La Spezia, Italy
| | | |
Collapse
|
7
|
Dufreneix S, Bellec J, Josset S, Vieillevigne L. Field output factors for small fields: A large multicentre study. Phys Med 2021; 81:191-196. [PMID: 33465756 DOI: 10.1016/j.ejmp.2021.01.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 12/30/2020] [Accepted: 01/02/2021] [Indexed: 02/06/2023] Open
Abstract
PURPOSE The determination of output factors in small field dosimetry is a crucial point, especially when implementing stereotactic radiotherapy (SRT). Herein, a working group of the French medical physicist society (SFPM) was created to collect small field output factors. The objective was to gather and disseminate information on small field output factors based on different detectors for various clinical SRT equipment and measurement configurations. METHOD Participants were surveyed for information about their SRT equipment, including the type of linear particle accelerator (linac), collimator settings, measurement conditions for the output factors and the detectors used. Participants had to report both the ratio of detector readings and the correction factors applied as described in the IAEA TRS-483 code of practice for nominal field sizes smaller or equal to 3 cm. Mean field output factors and their associated standard deviations were calculated when data from at least 3 linacs were available. RESULTS 23 centres were enrolled in the project. Standard deviations of the mean field output factors were systematically smaller than 1.5% for field sizes larger or equal to 1 cm and reached 5% for the smallest field size (0.5 cm). Deviations with published data were smaller than 2% except for the 0.5 cm circular fixed aperture collimator of the CyberKnife where it reached 3.5%. CONCLUSION These field output factor values obtained via a large multicentre study can be considered as an external cross verification for any radiotherapy centre starting a SRT program and should help minimize systematic errors when determining small field output factors.
Collapse
Affiliation(s)
- S Dufreneix
- Institut de Cancérologie de l'Ouest, Angers, Saint-Herblain, France.
| | - J Bellec
- Centre Eugène Marquis, Rennes, France
| | - S Josset
- Institut de Cancérologie de l'Ouest, Angers, Saint-Herblain, France
| | - L Vieillevigne
- Institut Claudius Régaud, Institut Universitaire du Cancer de Toulouse, France; Centre de Recherche et de Cancérologie de Toulouse, UMR1037 INSERM - Université Toulouse 3 - ERL5294 CNRS, Oncopole, Toulouse, France
| |
Collapse
|
8
|
A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery. Phys Eng Sci Med 2020; 43:593-599. [DOI: 10.1007/s13246-020-00859-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Accepted: 03/10/2020] [Indexed: 11/26/2022]
|
9
|
A national survey on technology and quality assurance for stereotactic body radiation therapy. Phys Med 2019; 65:6-14. [DOI: 10.1016/j.ejmp.2019.07.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 07/26/2019] [Accepted: 07/30/2019] [Indexed: 12/22/2022] Open
|
10
|
Russo S, Masi L, Francescon P, Dicarolo P, De Martin E, Frassanito C, Redaelli I, Vigorito S, Stasi M, Mancosu P. Multi-site evaluation of the Razor stereotactic diode for CyberKnife small field relative dosimetry. Phys Med 2019; 65:40-45. [DOI: 10.1016/j.ejmp.2019.07.027] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 07/22/2019] [Accepted: 07/30/2019] [Indexed: 10/26/2022] Open
|
11
|
The effect of SSD, Field size, Energy and Detector type for Relative Output Factor measurement in small photon beams as compared with Monte Carlo simulation. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2019. [DOI: 10.2478/pjmpe-2019-0014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
Introduction: Small fields photon dosimetry is associated with many problems. Using the right detector for measurement plays a fundamental role. This study investigated the measurement of relative output for small photon fields with different detectors. It was investigated for three-photon beam energies at SSDs of 90, 95, 100 and 110 cm. As a benchmark, the Monte Carlo simulation was done to calculate the relative output of these small photon beams for the dose in water.
Materials and Methods: 6, 10 and 15 MV beams were delivered from a Synergy LINAC equipped with an Agility 160 multileaf collimator (MLC). A CC01 ion chamber, EFD-3G diode, PTW60019 microdiamond, EBT2 radiochromic film, and EDR2 radiographic film were used to measure the relative output of the linac. Measurements were taken in water for the CC01 ion chamber, EFD-3G diode, and the PTW60019. Films were measured in water equivalent RW3 phantom slabs. Measurements were made for 1 × 1, 2 × 2, 3 × 3, 4 × 4, 5 × 5 and a reference field of 10 × 10 cm2. Field sizes were defined at 100cm SSD. Relative output factors were also compared with Monte Carlo (MC) simulation of the LINAC and a water phantom model. The influence of voxel size was also investigated for relative output measurement. Results and Discussion: The relative output factor (ROF) increased with energy for all fields large enough to have lateral electronic equilibrium (LEE). This relation broke down as the field sizes decreased due to the onset of lateral electronic disequilibrium (LED). The high-density detector, PTW60019 gave the highest ROF for the different energies, with the less dense CC01 giving the lowest ROFs.
Conclusion: These are results compared to MC simulation, higher density detectors give higher ROF values. Relative to water, the ROF measured with the air-chamber remained virtually unchanged. The ROFs, as measured in this study showed little variation due to increased SSDs. The effect of voxel size for the Monte Carlo calculations in water does not lead to significant ROF variation over the small fields studied.
Collapse
|
12
|
Gul A, Farrukh S, Kakakhel MB, Ilyas N, Naveed M, Haseeb A, Mirza SM. Measurement of 6 MV small field beam profiles - comparison of micro ionization chamber and linear diode array with monte carlo code. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:655-664. [PMID: 31205012 DOI: 10.3233/xst-190493] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The objective of this study is to analyze small field photon beams acquired with commonly available detectors. Beam profiles of 6 MV photons from the Siemens Primus Linear Accelerator were measured with a micro ion chamber (IC CC01, IBA) and linear diode array (LDA-99SC, IBA). Data was acquired using a water phantom for small fields (0.5×0.5 cm2 to 4×4 cm2) at depth of maximum dose, 5 cm and 10 cm. Profiles were also generated with EGSnrc Monte Carlo code. Measured and simulated profiles were compared in terms of percentage difference of the area under the simulated and measured profiles (PD), ratio of the measured to simulated dose at the point of maximum deviation within the central region of profile (R), full width half maximum (FWHM) and penumbra. For field sizes ≥1×1 cm2, the maximum PD is 3.17 % and 2.87 % for IC and LDA respectively, whereas R is in the range of 0.95-1.05 for IC and 0.99-1.05 for LDA. LDA measured FWHM and penumbra are also in better agreement with the simulated results. This study demonstrated that LDA can be used for acquisition of beam profiles for field size as low as 1×1 cm2.
Collapse
Affiliation(s)
- Attia Gul
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| | - Salman Farrukh
- Atomic Energy Medical Centre (AEMC), Jinnah Postgraduate Medical Centre (JPMC), Karachi, Pakistan
| | - M Basim Kakakhel
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| | - Nasir Ilyas
- Institution of Space and Planetary Astrophysics (ISPA), University of Karachi, Karachi, Pakistan
| | - Muhammad Naveed
- Atomic Energy Medical Centre (AEMC), Jinnah Postgraduate Medical Centre (JPMC), Karachi, Pakistan
| | - Abdul Haseeb
- Atomic Energy Medical Centre (AEMC), Jinnah Postgraduate Medical Centre (JPMC), Karachi, Pakistan
| | - Sikander M Mirza
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| |
Collapse
|
13
|
Talamonti C, Russo S, Pimpinella M, Falco MD, Cagni E, Pallotta S, Stasi M, Mancosu P. Community approach for reducing small field measurement errors: Experience over 24 centres. Radiother Oncol 2018; 132:218-222. [PMID: 30385173 DOI: 10.1016/j.radonc.2018.10.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2018] [Revised: 08/20/2018] [Accepted: 10/10/2018] [Indexed: 11/18/2022]
Abstract
PURPOSE The complexity of the modern Stereotactic Body Radiation Therapy (SBRT) techniques requires comprehensive quality assurance programs, to ensure the right treatment to the patient. Dosimetry of small radiation fields is a challenge especially for radiotherapy centres starting to work on this issue. The matter to be discussed here concerns the need of detailed measurement procedures and cross checks to be paired to the usual recommendations on detectors and correction factors. MATERIALS AND METHODS The presented work involved 24 Italian radiotherapy centres, with the specific purpose to minimize systematic errors in output factor measurements over different radiotherapy centres. Using the unshielded silicon diode IBA Razor, reference curves for the relative signal ratio (RSR) as a function of beam size were created for each Linac family. RESULTS With this study we have demonstrated consistency of small field dosimetry on all the centres involved, moreover all radiotherapy centres using Razor are allowed to compare measurements amongst each other and centres with values deviating more than 5% from the reference curve are advised to repeat their measurements. With this procedure, some critical issues were detected from two centres in RSR measurements, that, if implemented into the own treatment planning system, would induce an unwanted overdosage larger than 5%. CONCLUSIONS The proposed approach could allow one to envision high-skilled therapy centres providing support to those featuring minor experience and could represent an important strategy for the clinical implementation of emerging technologies at high quality levels. The methodology adopted exploits crowd knowledge methods which could be applied in others areas of radiation dosimetry.
Collapse
Affiliation(s)
- Cinzia Talamonti
- University of Florence, Dept Biomedical Experimental and Clinical Science, "Mario Serio", Medical Physics Unit, AOU Careggi, Florence, Italy.
| | - Serenella Russo
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - Maria Pimpinella
- Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA-INMRI C R Casaccia, I-00123 Roma, Italy
| | - Maria Daniela Falco
- Department of Radiation Oncology "G. D'Annunzio", University of Chieti, SS. Annunziata Hospital, Chieti, Italy
| | - Elisabetta Cagni
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Stefania Pallotta
- University of Florence, Dept Biomedical Experimental and Clinical Science, "Mario Serio", Medical Physics Unit, AOU Careggi, Florence, Italy
| | - Michele Stasi
- Medical Physics Department, A.O. Ordine Mauriziano, Turin, Italy
| | - Pietro Mancosu
- Medical Physics Unit of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milano, Italy
| |
Collapse
|
14
|
Nakayama S, Monzen H, Onishi Y, Kaneshige S, Kanno I. Estimation of extremely small field radiation dose for brain stereotactic radiotherapy using the Vero4DRT system. Phys Med 2018; 50:52-58. [DOI: 10.1016/j.ejmp.2018.05.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 05/23/2018] [Accepted: 05/24/2018] [Indexed: 10/14/2022] Open
|
15
|
Reggiori G, Stravato A, Mancosu P, Lobefalo F, Paganini L, Zucconi F, Palumbo V, Gaudino A, Scorsetti M, Tomatis S. Small field characterization of a Nanochamber prototype under flattening filter free photon beams. Phys Med 2018; 49:139-146. [DOI: 10.1016/j.ejmp.2017.08.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Revised: 08/04/2017] [Accepted: 08/16/2017] [Indexed: 11/28/2022] Open
|
16
|
Damodar J, Odgers D, Pope D, Hill R. A study on the suitability of the PTW microDiamond detector for kilovoltage x-ray beam dosimetry. Appl Radiat Isot 2018; 135:104-109. [DOI: 10.1016/j.apradiso.2018.01.025] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2017] [Revised: 12/12/2017] [Accepted: 01/16/2018] [Indexed: 11/25/2022]
|
17
|
Clemente S, Masi L, Fiandra C, Cagni E, Villaggi E, Esposito M, Giglioli FR, Marino C, Strigari L, Garibaldi C, Stasi M, Mancosu P, Russo S. A multi-center output factor intercomparison to uncover systematic inaccuracies in small field dosimetry. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2018; 5:93-96. [PMID: 33458376 PMCID: PMC7807548 DOI: 10.1016/j.phro.2018.03.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 03/15/2018] [Accepted: 03/15/2018] [Indexed: 11/28/2022]
Abstract
Large uncertainties in output factor (OF) small fields dosimetry motivated multicentric studies. The focus of the study was the determination of the OFs, for different linacs and radiosurgery units, using new-generation detectors. Intercomparison studies between radiotherapy centers improved quality dosimetry practices. Results confirmed the effectiveness of the studies to uncover large systematic inaccuracies in small field dosimetry.
Collapse
Affiliation(s)
- Stefania Clemente
- Unit of Medical Physics and Radioprotection, A.O.U Federico II, Napoli, Italy
| | - Laura Masi
- Department of Medical Physics and Radiation Oncology, IFCA, I-50139 Firenze, Italy
| | - Christian Fiandra
- Department of Oncology, Radiation Oncology Unit, University of Torino, Italy
| | | | | | - Marco Esposito
- Medical Physics Unit, Azienda USL Toscana Centro, Firenze I-50012, Italy
| | | | | | - Lidia Strigari
- Laboratory of Medical Physics and Expert Systems, Regina Elena Cancer Center IFO, Roma, Italy
| | - Cristina Garibaldi
- Unit of Radiation Research, European Institute of Oncology, Milano, Italy
| | | | - Pietro Mancosu
- Medical Physics Unit of Radiation Oncology Dept., Humanitas Research Hospital, Milano, Italy
| | - Serenella Russo
- Medical Physics Unit, Azienda USL Toscana Centro, Firenze I-50012, Italy
| |
Collapse
|
18
|
Mancosu P, Nisbet A, Jornet N. Editorial: The role of medical physics in lung SBRT. Phys Med 2018; 45:205-206. [PMID: 29325801 DOI: 10.1016/j.ejmp.2018.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 01/03/2018] [Indexed: 12/24/2022] Open
Abstract
Stereotactic body radiation therapy (SBRT) has become a standard treatment for non-operable patients with early stage non-small cell lung cancer (NSCLC). In this context, medical physics community has largely helped in the starting and the growth of this technique. In fact, SBRT requires the convergence of many different features for delivering large doses in few fractions to small moving target in an heterogeneous medium. The special issue of last month, was focused on the different physics challenges in lung SBRT. Eleven reviews were presented, covering: imaging for treatment planning and for treatment assessment; dosimetry and planning optimization; treatment delivery possibilities; image guidance during delivery; radiobiology. The current cutting edge role of medical physics was reported. We aimed to give a complete overview of different aspects of lung SBRT that would be of interest to both physicists implementing this technique in their institutions and more experienced physicists that would be inspired to start research projects in areas that still need further developments. We also feel that the role that medical physicists have played in the development and safe implementation of SBRT, particularly in lung region, can be taken as an excellent example to be translated to other areas, not only in Radiation Oncology but also in other health sectors.
Collapse
Affiliation(s)
- Pietro Mancosu
- Medical Physics service, Radiotherapy department, Humanitas Cancer Center, Rozzano-Milan, Italy.
| | - Andrew Nisbet
- Department of Medical Physics, Royal Surrey County Hospital, United Kingdom; Department of Physics, Faculty of Engineering & Physical Sciences, University of Surrey, United Kingdom
| | - Núria Jornet
- Servei de Radiofísica i Radioprotecció, Hospital Sant Pau, Barcelona, Spain
| |
Collapse
|
19
|
Veselsky T, Novotny J, Pastykova V, Koniarova I. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator. Phys Med 2017; 44:66-71. [DOI: 10.1016/j.ejmp.2017.11.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2017] [Revised: 10/09/2017] [Accepted: 11/09/2017] [Indexed: 10/18/2022] Open
|
20
|
Giglioli FR, Clemente S, Esposito M, Fiandra C, Marino C, Russo S, Strigari L, Villaggi E, Stasi M, Mancosu P. Frontiers in planning optimization for lung SBRT. Phys Med 2017; 44:163-170. [PMID: 28566240 DOI: 10.1016/j.ejmp.2017.05.064] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Revised: 05/19/2017] [Accepted: 05/22/2017] [Indexed: 12/25/2022] Open
Abstract
Emerging data are showing the safety and the efficacy of Stereotactic Body Radiation therapy (SBRT) in lung cancer management. In this context, the very high doses delivered to the Planning Target Volume, make the planning phase essential for achieving high dose levels conformed to the shape of the target in order to have a good prognosis for tumor control and to avoid an overdose in relevant healthy adjacent tissue. In this non-systematic review we analyzed the technological and the physics aspects of SBRT planning for lung cancer. In particular, the aims of the study were: (i) to evaluate prescription strategies (homogeneous or inhomogeneous), (ii) to outline possible geometrical solutions by comparing the dosimetric results (iii) to describe the technological possibilities for a safe and effective treatment, (iv) to present the issues concerning radiobiological planning and the automation of the planning process.
Collapse
Affiliation(s)
| | | | | | - Christian Fiandra
- Dep. of Oncology Radiation Oncology Unit, University of Torino, Italy
| | | | | | - Lidia Strigari
- Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer, Institute IFO, Rome, Italy
| | | | - Michele Stasi
- Medical Physics Dept., Azienda Ospedaliera Ordine Mauriziano di Torino, Torino, Italy
| | - Pietro Mancosu
- Medical Physics Unit of Radiotherapy Dept., Humanitas Clinical and Research Hospital, Rozzano (MI), Italy
| |
Collapse
|
21
|
Zoros E, Moutsatsos A, Pappas EP, Georgiou E, Kollias G, Karaiskos P, Pantelis E. Monte Carlo and experimental determination of correction factors for gamma knife perfexion small field dosimetry measurements. Phys Med Biol 2017; 62:7532-7555. [PMID: 28796643 DOI: 10.1088/1361-6560/aa8590] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Detector-, field size- and machine-specific correction factors are required for precise dosimetry measurements in small and non-standard photon fields. In this work, Monte Carlo (MC) simulation techniques were used to calculate the [Formula: see text] and [Formula: see text] correction factors for a series of ionization chambers, a synthetic microDiamond and diode dosimeters, used for reference and/or output factor (OF) measurements in the Gamma Knife Perfexion photon fields. Calculations were performed for the solid water (SW) and ABS plastic phantoms, as well as for a water phantom of the same geometry. MC calculations for the [Formula: see text] correction factors in SW were compared against corresponding experimental results for a subset of ionization chambers and diode detectors. Reference experimental OF data were obtained through the weighted average of corresponding measurements using TLDs, EBT-2 films and alanine pellets. [Formula: see text] values close to unity (within 1%) were calculated for most of ionization chambers in water. Greater corrections of up to 6.0% were observed for chambers with relatively large air-cavity dimensions and steel central electrode. A phantom correction of 1.006 and 1.024 (breaking down to 1.014 from the ABS sphere and 1.010 from the accompanying ABS phantom adapter) were calculated for the SW and ABS phantoms, respectively, adding up to [Formula: see text] corrections in water. Both measurements and MC calculations for the diode and microDiamond detectors resulted in lower than unit [Formula: see text] correction factors, due to their denser sensitive volume and encapsulation materials. In comparison, higher than unit [Formula: see text] results for the ionization chambers suggested field size depended dose underestimations (being significant for the 4 mm field), with magnitude depending on the combination of contradicting phenomena associated with volume averaging and electron fluence perturbations. Finally, the presence of 0.5 mm air-gap between the diodes' frontal surface and their phantom-inserts may considerably influence OF measurements, reaching 4.6% for the Razor diode.
Collapse
Affiliation(s)
- E Zoros
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 115 27 Athens, Greece
| | | | | | | | | | | | | |
Collapse
|
22
|
Dosimetric characterization of small fields using a plastic scintillator detector: A large multicenter study. Phys Med 2017; 41:33-38. [DOI: 10.1016/j.ejmp.2017.03.024] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 03/23/2017] [Accepted: 03/28/2017] [Indexed: 12/31/2022] Open
|
23
|
Reggiori G, Stravato A, Pimpinella M, Lobefalo F, De Coste V, Fogliata A, Mancosu P, De Rose F, Palumbo V, Scorsetti M, Tomatis S. Use of PTW-microDiamond for relative dosimetry of unflattened photon beams. Phys Med 2017; 38:45-53. [PMID: 28610696 DOI: 10.1016/j.ejmp.2017.05.046] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 01/31/2017] [Accepted: 05/03/2017] [Indexed: 10/19/2022] Open
Abstract
PURPOSE The increasing interest in SBRT treatments encourages the use of flattening filter free (FFF) beams. Aim of this work was to evaluate the performance of the PTW60019 microDiamond detector under 6MV and 10MVFFF beams delivered with the EDGE accelerator (Varian Medical System, Palo Alto, USA). A flattened 6MV beam was also considered for comparison. METHODS Short term stability, dose linearity and dose rate dependence were evaluated. Dose per pulse dependence was investigated in the range 0.2-2.2mGy/pulse. MicroDiamond profiles and output factors (OFs) were compared to those obtained with other detectors for field sizes ranging from 40×40cm2 to 0.6×0.6cm2. In small fields, volume averaging effects were evaluated and the relevant correction factors were applied for each detector. RESULTS MicroDiamond short term stability, dose linearity and dependence on monitor unit rate were less than 0.8% for all energies. Response variations with dose per pulse were found within 1.8%. MicroDiamond output factors (OF) values differed from those measured with the reference ion-chamber for less than 1% up to 40×40cm2 fields where silicon diodes overestimate the dose of ≈3%. For small fields (<3×3cm2) microDiamond and the unshielded silicon diode were in good agreement. CONCLUSIONS MicroDiamond showed optimal characteristics for relative dosimetry even under high dose rate beams. The effects due to dose per pulse dependence up to 2.2mGy/pulse are negligible. Compared to other detectors, microDiamond provides accurate OF measurements in the whole range of field sizes. For fields <1cm correction factors accounting for fluence perturbation and volume averaging could be required.
Collapse
Affiliation(s)
- Giacomo Reggiori
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy.
| | - Antonella Stravato
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| | - Maria Pimpinella
- Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA-INMRI C R Casaccia, Roma, Italy
| | - Francesca Lobefalo
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| | - Vanessa De Coste
- Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA-INMRI C R Casaccia, Roma, Italy
| | - Antonella Fogliata
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| | - Pietro Mancosu
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| | - Fiorenza De Rose
- Radiotherapy and Radiosurgery Department, Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| | - Valentina Palumbo
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| | - Marta Scorsetti
- Radiotherapy and Radiosurgery Department, Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy; Department of Biomedical Sciences, Humanitas University, Rozzano, Milano, Italy
| | - Stefano Tomatis
- Physics Service of Radiation Oncology Dept., Humanitas Clinical and Research Hospital, Milan-Rozzano, Italy
| |
Collapse
|
24
|
Fiorino C, Gori C. 9th Congress of the Associazione Italiana di Fisica Medica, Perugia 25–28 February 2016, “ Continuity and evolution in medical physics ”. Phys Med 2016; 32:1634-1636. [DOI: 10.1016/j.ejmp.2016.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/05/2016] [Indexed: 11/16/2022] Open
|