• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (5050569)   Today's Articles (0)
For: Choi HJ, Chung HT, Sohn JW, Min CH. Independent dose validation system for Gamma Knife radiosurgery, using a DICOM-RT interface and Geant4. Phys Med 2018;51:117-24. [PMID: 29914795 DOI: 10.1016/j.ejmp.2018.06.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 06/08/2018] [Accepted: 06/09/2018] [Indexed: 11/21/2022]  Open
Number Cited by Other Article(s)
1
Han EY, Diagaradjane P, Luo D, Ding Y, Kalaitzakis G, Zoros E, Zourari K, Boursianis T, Pappas E, Wen Z, Wang J, Briere TM. Validation of PTV margin for Gamma Knife Icon frameless treatment using a PseudoPatient® Prime anthropomorphic phantom. J Appl Clin Med Phys 2020;21:278-285. [PMID: 32786141 PMCID: PMC7497928 DOI: 10.1002/acm2.12997] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 04/28/2020] [Accepted: 06/23/2020] [Indexed: 11/09/2022]  Open
2
Logothetis A, Pantelis E, Zoros E, Pappas EP, Dimitriadis A, Paddick I, Garding J, Johansson J, Kollias G, Karaiskos P. Dosimetric evaluation of the Leksell GammaPlan Convolution dose calculation algorithm. Phys Med Biol 2020;65:045011. [PMID: 31860889 DOI: 10.1088/1361-6560/ab64b7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
3
Cheon BW, Yoo DH, Shin WG, Choi HJ, Park HJ, Kim JI, Min CH. Development of advanced skin dose evaluation technique using a tetrahedral-mesh phantom in external beam radiotherapy: a Monte Carlo simulation study. Phys Med Biol 2019;64:165005. [PMID: 31269480 DOI: 10.1088/1361-6560/ab2ef5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
4
Choi HJ, Park H, Yi CY, Kim BC, Shin WG, Min CH. Determining the energy spectrum of clinical linear accelerator using an optimized photon beam transmission protocol. Med Phys 2019;46:3285-3297. [PMID: 31055830 DOI: 10.1002/mp.13569] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 04/09/2019] [Accepted: 04/25/2019] [Indexed: 12/29/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA