Koike Y, Ohira S, Yamamoto Y, Miyazaki M, Konishi K, Nakamura S, Tanigawa N. Artificial intelligence-based image-domain material decomposition in single-energy computed tomography for head and neck cancer. Int J Comput Assist Radiol Surg 2024; 19:541-551. [PMID: 38219257 DOI: 10.1007/s11548-023-03058-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 12/28/2023] [Indexed: 01/16/2024]
Abstract
PURPOSE While dual-energy computed tomography (DECT) images provide clinically useful information than single-energy CT (SECT), SECT remains the most widely used CT system globally, and only a few institutions can use DECT. This study aimed to establish an artificial intelligence (AI)-based image-domain material decomposition technique using multiple keV-output learning of virtual monochromatic images (VMIs) to create DECT-equivalent images from SECT images. METHODS This study involved 82 patients with head and neck cancer. Of these, the AI model was built with data from the 67 patients with only DECT scans, while 15 patients with both SECT and DECT scans were used for SECT testing. Our AI model generated VMI50keV and VMI100keV from VMI70keV equivalent to 120-kVp SECT images. We introduced a loss function for material density images (MDIs) in addition to the loss for VMIs. For comparison, we trained the same model with the loss for VMIs only. DECT-equivalent images were generated from SECT images and compared with the true DECT images. RESULTS The prediction time was 5.4 s per patient. The proposed method with the MDI loss function quantitatively provided more accurate DECT-equivalent images than the model trained with the loss for VMIs only. Using real 120-kVp SECT images, the trained model produced precise DECT images of excellent quality. CONCLUSION In this study, we developed an AI-based material decomposition approach for head and neck cancer patients by introducing the loss function for MDIs via multiple keV-output learning. Our results suggest the feasibility of AI-based image-domain material decomposition in a conventional SECT system without a DECT scanner.
Collapse
Affiliation(s)
- Yuhei Koike
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
- Division of Radiation Oncology, Kansai Medical University Hospital, 2-3-1 Shinmachi, Hirakata, Osaka, 573-1191, Japan.
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yuki Yamamoto
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Satoaki Nakamura
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
- Division of Radiation Oncology, Kansai Medical University Hospital, 2-3-1 Shinmachi, Hirakata, Osaka, 573-1191, Japan
| | - Noboru Tanigawa
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| |
Collapse
|
2
|
Koike Y, Ohira S, Teraoka Y, Matsumi A, Imai Y, Akino Y, Miyazaki M, Nakamura S, Konishi K, Tanigawa N, Ogawa K. Pseudo low-energy monochromatic imaging of head and neck cancers: Deep learning image reconstruction with dual-energy CT. Int J Comput Assist Radiol Surg 2022; 17:1271-1279. [PMID: 35415780 DOI: 10.1007/s11548-022-02627-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 03/24/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Low-energy virtual monochromatic images (VMIs) derived from dual-energy computed tomography (DECT) systems improve lesion conspicuity of head and neck cancer over single-energy CT (SECT). However, DECT systems are installed in a limited number of facilities; thus, only a few facilities benefit from VMIs. In this work, we present a deep learning (DL) architecture suitable for generating pseudo low-energy VMIs of head and neck cancers for facilities that employ SECT imaging. METHODS We retrospectively analyzed 115 patients with head and neck cancers who underwent contrast enhanced DECT. VMIs at 70 and 50 keV were used as the input and ground truth (GT), respectively. We divided them into two datasets: for DL (104 patients) and for inference with SECT (11 patients). We compared four DL architectures: U-Net, DenseNet-based, and two ResNet-based models. Pseudo VMIs at 50 keV (pVMI50keV) were compared with the GT in terms of the mean absolute error (MAE) of Hounsfield unit (HU) values, peak signal-to-noise ratio (PSNR), and structural similarity (SSIM). The HU values for tumors, vessels, parotid glands, muscle, fat, and bone were evaluated. pVMI50keV were generated from actual SECT images and the HU values were evaluated. RESULTS U-Net produced the lowest MAE (13.32 ± 2.20 HU) and highest PSNR (47.03 ± 2.33 dB) and SSIM (0.9965 ± 0.0009), with statistically significant differences (P < 0.001). The HU evaluation showed good agreement between the GT and U-Net. U-Net produced the smallest absolute HU difference for the tumor, at < 5.0 HU. CONCLUSION Quantitative comparisons of physical parameters demonstrated that the proposed U-Net could generate high accuracy pVMI50keV in a shorter time compared with the established DL architectures. Although further evaluation on diagnostic accuracy is required, our method can help obtain low-energy VMI from SECT images without DECT systems.
Collapse
Affiliation(s)
- Yuhei Koike
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Yuri Teraoka
- GE Healthcare Japan Corporation, 4-7-127 Asahigaoka, Hino, Tokyo, 191-8503, Japan
| | - Ayako Matsumi
- GE Healthcare Japan Corporation, 4-7-127 Asahigaoka, Hino, Tokyo, 191-8503, Japan
| | - Yasuhiro Imai
- GE Healthcare Japan Corporation, 4-7-127 Asahigaoka, Hino, Tokyo, 191-8503, Japan
| | - Yuichi Akino
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Satoaki Nakamura
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Noboru Tanigawa
- Department of Radiology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|