Di Franco M, Fortunati E, Zanoni L, Bonazzi N, Mosconi C, Malizia C, Civollani S, Campana D, Andrini E, Lamberti G, Allegri V, Fanti S, Ambrosini V. β1600 Q.Clear Digital Reconstruction of [ 68Ga]Ga-DOTANOC PET/CT Improves Image Quality in NET Patients. J Clin Med 2024; 13:3841. [PMID: 38999406 PMCID: PMC11242716 DOI: 10.3390/jcm13133841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 06/24/2024] [Accepted: 06/26/2024] [Indexed: 07/14/2024] Open
Abstract
Background: Image reconstruction is crucial for improving overall image quality and diagnostic accuracy. Q.Clear is a novel reconstruction algorithm that reduces image noise. The aim of the present study is to assess the preferred Q.Clear β-level for digital [68Ga]Ga-DOTANOC PET/CT reconstruction vs. standard reconstruction (STD) for both overall scan and single-lesion visualization. Methods: Inclusion criteria: (1) patients with/suspected neuroendocrine tumors included in a prospective observational monocentric study between September 2019 and January 2022; (2) [68Ga]Ga-DOTANOC digital PET/CT and contrast-enhanced-CT (ceCT) performed at our center at the same time. Images were reconstructed with STD and with Q.Clear β-levels 800, 1000, and 1600. Scans were blindly reviewed by three nuclear-medicine experts: the preferred β-level reconstruction was independently chosen for the visual quality of both the overall scan and the most avid target lesion < 1 cm (t) and >1 cm (T). PET/CT results were compared to ceCT. Semiquantitative analysis was performed (STD vs. β1600) in T and t concordant at both PET/CT and ceCT. Subgroup analysis was also performed in patients presenting discordant t. Results: Overall, 52 patients were included. β1600 reconstruction was considered superior over the others for both overall scan quality and single-lesion detection in all cases. The only significantly different (p < 0.001) parameters between β1600 and STD were signal-to-noise liver ratio and standard deviation of the liver background. Lesion-dependent parameters were not significantly different in concordant T (n = 37) and t (n = 10). Among 26 discordant t, when PET was positive, all findings were confirmed as malignant. Conclusions: β1600 Q.Clear reconstruction for [68Ga]Ga-DOTANOC imaging is feasible and improves image quality for both overall and small-lesion assessment.
Collapse
Affiliation(s)
- Martina Di Franco
- Nuclear Medicine, Alma Mater Studiorum, University of Bologna, 40126 Bologna, Italy
| | - Emilia Fortunati
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Lucia Zanoni
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Norma Bonazzi
- Nuclear Medicine, Alma Mater Studiorum, University of Bologna, 40126 Bologna, Italy
| | - Cristina Mosconi
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum, University of Bologna, 40138 Bologna, Italy
- Department of Radiology, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Claudio Malizia
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Simona Civollani
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Davide Campana
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum, University of Bologna, 40138 Bologna, Italy
- Medical Oncology, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Elisa Andrini
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum, University of Bologna, 40138 Bologna, Italy
- Medical Oncology, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Giuseppe Lamberti
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum, University of Bologna, 40138 Bologna, Italy
- Medical Oncology, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Vincenzo Allegri
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Stefano Fanti
- Nuclear Medicine, Alma Mater Studiorum, University of Bologna, 40126 Bologna, Italy
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Valentina Ambrosini
- Nuclear Medicine, Alma Mater Studiorum, University of Bologna, 40126 Bologna, Italy
- Nuclear Medicine, IRCCS, Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| |
Collapse
|
2
|
Cox CPW, Brabander T, Vegt E, de Lussanet de la Sablonière QG, Graven LH, Verburg FA, Segbers M. Reduction of [ 68Ga]Ga-DOTA-TATE injected activity for digital PET/MR in comparison with analogue PET/CT. EJNMMI Phys 2024; 11:27. [PMID: 38488989 PMCID: PMC11266332 DOI: 10.1186/s40658-024-00629-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 03/06/2024] [Indexed: 03/17/2024] Open
Abstract
BACKGROUND New digital detectors and block-sequential regularized expectation maximization (BSREM) reconstruction algorithm improve positron emission tomography (PET)/magnetic resonance (MR) image quality. The impact on image quality may differ from analogue PET/computed tomography (CT) protocol. The aim of this study is to determine the potential reduction of injected [68Ga]Ga-DOTA-TATE activity for digital PET/MR with BSREM reconstruction while maintaining at least equal image quality compared to the current analogue PET/CT protocol. METHODS NEMA IQ phantom data and 25 patients scheduled for a diagnostic PET/MR were included. According to our current protocol, 1.5 MBq [68Ga]Ga-DOTA-TATE per kilogram (kg) was injected. After 60 min, scans were acquired with 3 (≤ 70 kg) or 4 (> 70 kg) minutes per bedposition. PET/MR scans were reconstructed using BSREM and factors β 150, 300, 450 and 600. List mode data with reduced counts were reconstructed to simulate scans with 17%, 33%, 50% and 67% activity reduction. Image quality was measured quantitatively for PET/CT and PET/MR phantom and patient data. Experienced nuclear medicine physicians performed visual image quality scoring and lesion counting in the PET/MR patient data. RESULTS Phantom analysis resulted in a possible injected activity reduction of 50% with factor β = 600. Quantitative analysis of patient images revealed a possible injected activity reduction of 67% with factor β = 600. Both with equal or improved image quality as compared to PET/CT. However, based on visual scoring a maximum activity reduction of 33% with factor β = 450 was acceptable, which was further limited by lesion detectability analysis to an injected activity reduction of 17% with factor β = 450. CONCLUSION A digital [68Ga]Ga-DOTA-TATE PET/MR together with BSREM using factor β = 450 result in 17% injected activity reduction with quantitative values at least similar to analogue PET/CT, without compromising on PET/MR visual image quality and lesion detectability.
Collapse
Affiliation(s)
- Christina P W Cox
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands.
| | - Tessa Brabander
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Erik Vegt
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Quido G de Lussanet de la Sablonière
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Laura H Graven
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Frederik A Verburg
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| |
Collapse
|
3
|
Zorz A, D'Alessio A, Guida F, Ramadan RM, Richetta E, Cuppari L, Pellerito R, Sacchetti GM, Brambilla M, Paiusco M, Stasi M, Matheoud R. Impact of patient's habitus on image quality and quantitative metrics in 18F-FDG PET/CT images. Phys Med 2023; 109:102584. [PMID: 37060633 DOI: 10.1016/j.ejmp.2023.102584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 03/24/2023] [Accepted: 04/06/2023] [Indexed: 04/17/2023] Open
Abstract
PURPOSE To study how the quantitative parameters of 18F-FDG PET imaging change with the emission scan duration (ESD) and the body-mass-index (BMI) in phantom and patients on a time-of-flight (TOF)-PET/CT system. METHODS The image-quality phantom with (b-NEMA-IQ, BMI = 29.2 kg/m2) and without (NEMA-IEC, BMI = 21.4 kg/m2) a 'belt' of water-bags was filled with 18F-FDG activities to obtain nominal standardized uptake values (SUV) of 19, 8 and 5. Patients with BMI ≤ 25 kg/m2 (L-BMI) and BMI > 25 kg/m2 (H-BMI) were enrolled in this study. Phantom and patients underwent list-mode PET acquisition at 120 s/bed-position. Images reconstructed with clinical protocol and different ESD (120, 90, 75, 60, 45, 30 s) were analysed for comparison of maximum SUV (SUVmax), maximum standardized uptake value lean-body-mass corrected (SULmax) and noise. RESULTS 79 oncologic patients (45 L-BMI, 44 H-BMI) were analysed. From 90 s to 30 s, an increasing variation of SUVmax and SULmax with respect to the reference 120 s time was observed, from 18% to 60% and from 16% to 37% for phantom and patients, respectively. SUVmax values were significantly higher (+50%) in b-NEMA-IQ than NEMA-IQ phantom and in H-BMI (+33%) than L-BMI patients. No significant difference was found in SULmax for the two BMI categories in both phantom and patients. CV values decreased when increasing ESD, being higher in H-BMI patients (0.13-0.25) and b-NEMA-IQ phantom (0.15-0.28) than in L-BMI patients (0.11-0.21) and NEMA-IQ phantom (0.11-0.20). CONCLUSIONS Reduction of ESD may severely impact on the variations of SUVmax and SULmax in 18F-FDG PET/CT imaging. This study confirms recommendations of using SUL for lesion uptake quantification, being unaffected by BMI variation.
Collapse
Affiliation(s)
- Alessandra Zorz
- Medical Physics Department, Istituto Oncologico Veneto IOV-IRCCS, Via Gattamelata 64, Padova, Italy
| | - Andrea D'Alessio
- Medical Physics Department, University Hospital Maggiore della Carità, C.so Mazzini 18, Novara, Italy
| | - Federica Guida
- Medical Physics Department, Istituto Oncologico Veneto IOV-IRCCS, Via Gattamelata 64, Padova, Italy
| | - Rehema Masaka Ramadan
- Department of Medical Physics, University of Trieste, Via Tiepolo 11, Trieste, Italy; Abdus Salam International Centre for Theoretical Physics (ICTP), Strada Costiera 11, Trieste, Italy
| | - Elisa Richetta
- Medical Physics Department, AO Ordine Mauriziano di Torino, Via Magellano 1, Torino, Italy
| | - Lea Cuppari
- Nuclear Medicine Department, Istituto Oncologico Veneto IOV-IRCCS, Padova, Italy
| | - Riccardo Pellerito
- Nuclear Medicine Department, AO Ordine Mauriziano Torino, Via Magellano 1, Torino, Italy
| | - Gian Mauro Sacchetti
- Nuclear Medicine Department, University Hospital Maggiore della Carità, Novara, Italy
| | - Marco Brambilla
- Medical Physics Department, University Hospital Maggiore della Carità, C.so Mazzini 18, Novara, Italy
| | - Marta Paiusco
- Medical Physics Department, Istituto Oncologico Veneto IOV-IRCCS, Via Gattamelata 64, Padova, Italy
| | - Michele Stasi
- Medical Physics Department, AO Ordine Mauriziano di Torino, Via Magellano 1, Torino, Italy
| | - Roberta Matheoud
- Medical Physics Department, University Hospital Maggiore della Carità, C.so Mazzini 18, Novara, Italy.
| |
Collapse
|
4
|
Miwa K, Miyaji N, Yamao T, Kamitaka Y, Wagatsuma K, Murata T. [[PET] 5. Recent Advances in PET Image Reconstruction Using a Bayesian Penalized Likelihood Algorithm]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023; 79:477-487. [PMID: 37211404 DOI: 10.6009/jjrt.2023-2200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Affiliation(s)
- Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
| | - Noriaki Miyaji
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
| | - Tensho Yamao
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
| | - Yuto Kamitaka
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
| | - Kei Wagatsuma
- Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology
- School of Allied Health Sciences, Kitasato University
| | | |
Collapse
|