Collamati F, Morganti S, van Oosterom MN, Campana L, Ceci F, Luzzago S, Mancini-Terracciano C, Mirabelli R, Musi G, Nicolanti F, Orsi I, van Leeuwen FWB, Faccini R. First-in-human validation of a DROP-IN β-probe for robotic radioguided surgery: defining optimal signal-to-background discrimination algorithm. Eur J Nucl Med Mol Imaging 2024; 51:3098-3108. [PMID: 38376805 PMCID: PMC11300660 DOI: 10.1007/s00259-024-06653-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 02/07/2024] [Indexed: 02/21/2024]
Abstract
PURPOSE In radioguided surgery (RGS), radiopharmaceuticals are used to generate preoperative roadmaps (e.g., PET/CT) and to facilitate intraoperative tracing of tracer avid lesions. Within RGS, there is a push toward the use of receptor-targeted radiopharmaceuticals, a trend that also has to align with the surgical move toward minimal invasive robotic surgery. Building on our initial ex vivo evaluation, this study investigates the clinical translation of a DROP-IN β probe in robotic PSMA-guided prostate cancer surgery. METHODS A clinical-grade DROP-IN β probe was developed to support the detection of PET radioisotopes (e.g., 68 Ga). The prototype was evaluated in 7 primary prostate cancer patients, having at least 1 lymph node metastases visible on PSMA-PET. Patients were scheduled for radical prostatectomy combined with extended pelvic lymph node dissection. At the beginning of surgery, patients were injected with 1.1 MBq/kg of [68Ga]Ga-PSMA. The β probe was used to trace PSMA-expressing lymph nodes in vivo. To support intraoperative decision-making, a statistical software algorithm was defined and optimized on this dataset to help the surgeon discriminate between probe signals coming from tumors and healthy tissue. RESULTS The DROP-IN β probe helped provide the surgeon with autonomous and highly maneuverable tracer detection. A total of 66 samples (i.e., lymph node specimens) were analyzed in vivo, of which 31 (47%) were found to be malignant. After optimization of the signal cutoff algorithm, we found a probe detection rate of 78% of the PSMA-PET-positive samples, a sensitivity of 76%, and a specificity of 93%, as compared to pathologic evaluation. CONCLUSION This study shows the first-in-human use of a DROP-IN β probe, supporting the integration of β radio guidance and robotic surgery. The achieved competitive sensitivity and specificity help open the world of robotic RGS to a whole new range of radiopharmaceuticals.
Collapse
Affiliation(s)
| | - Silvio Morganti
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
| | - Matthias N van Oosterom
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Lorenzo Campana
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
- Department of Scienze di Base e Applicate per l'Ingegneria (SBAI), Sapienza University of Rome, Rome, Italy
| | - Francesco Ceci
- Division of Nuclear Medicine, IEO, European Institute of Oncology IRCCS, Milan, Italy
- Department of Oncology and Hematology-Oncology, University of Milan, Milan, Italy
| | - Stefano Luzzago
- Department of Oncology and Hematology-Oncology, University of Milan, Milan, Italy
- Department of Urology, IEO European Institute of Oncology, IRCCS, Milan, Italy
| | - Carlo Mancini-Terracciano
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
- Department of Physics, Sapienza University of Rome, Rome, Italy
| | - Riccardo Mirabelli
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy.
- Department of Scienze di Base e Applicate per l'Ingegneria (SBAI), Sapienza University of Rome, Rome, Italy.
| | - Gennaro Musi
- Department of Oncology and Hematology-Oncology, University of Milan, Milan, Italy
- Department of Urology, IEO European Institute of Oncology, IRCCS, Milan, Italy
| | - Francesca Nicolanti
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
- Department of Physics, Sapienza University of Rome, Rome, Italy
| | - Ilaria Orsi
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
- Department of Physics, Sapienza University of Rome, Rome, Italy
| | - Fijs W B van Leeuwen
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Riccardo Faccini
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
- Department of Physics, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
2
|
Collarino A, Florit A, Bizzarri N, Lanni V, Morganti S, De Summa M, Vizzielli G, Fanfani F, Mirabelli R, Ferrandina G, Scambia G, Rufini V, Faccini R, Collamati F. Radioguided surgery with β decay: A feasibility study in cervical cancer. Phys Med 2023; 113:102658. [PMID: 37603908 DOI: 10.1016/j.ejmp.2023.102658] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 07/07/2023] [Accepted: 08/05/2023] [Indexed: 08/23/2023] Open
Abstract
PURPOSE Radioguided surgery (RGS) is a technique that helps the surgeon to achieve a tumour resection as complete as possible, by means of the intraoperative detection of particles emitted by a radiotracer that bounds to tumoural cells. This study aimed to investigate the applicability of β-RGS for tumour resection and margin assessment in cervical cancer patients preoperatively injected with [18F]FDG, by means of Monte Carlo simulations. METHODS Patients were retrospectively included if they had a recurrent or persistent cervical cancer, underwent preoperative PET/CT to exclude distant metastases and received radical surgery. All PET/CT images were analysed extracting tumour SUVmax, background SUVmean and tumour-to-non-tumour ratio. These values were used to obtain the expected count rate in a realistic surgical scenario by means of a Monte Carlo simulation of the β probe, assuming the injection of 2 MBq/kg of [18F]FDG 60 min before surgery. RESULTS Thirty-eight patients were included. A measuring time of ∼2-3 s is expected to be sufficient for discriminating the tumour from background in a given lesion, being this the time the probe has to be over the sample in order to be able to discriminate tumour from healthy tissue with a sensitivity of ∼99% and a specificity of at least 95%. CONCLUSION This study presents the first step towards a possible application of our β-RGS technique in cervical cancer. Results suggest that this approach to β-RGS could help surgeons distinguish tumour margins from surrounding healthy tissue, even in a setting of high radiotracer background activity.
Collapse
Affiliation(s)
- Angela Collarino
- Nuclear Medicine Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
| | - Anita Florit
- Section of Nuclear Medicine, University Department of Radiological Sciences and Hematology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Nicolò Bizzarri
- Gynecologic Oncology Unit, Department of Women, Children and Public Health Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Valerio Lanni
- Nuclear Medicine Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Silvio Morganti
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy
| | - Marco De Summa
- PET/CT Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Giuseppe Vizzielli
- Gynecologic Oncology Unit, Department of Women, Children and Public Health Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Francesco Fanfani
- Gynecologic Oncology Unit, Department of Women, Children and Public Health Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; Institute of Obstetrics and Gynecology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Riccardo Mirabelli
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy; Department of Basic and Applied Sciences for Engineering, Sapienza Università di Roma, Rome, Italy.
| | - Gabriella Ferrandina
- Gynecologic Oncology Unit, Department of Women, Children and Public Health Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; Institute of Obstetrics and Gynecology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Giovanni Scambia
- Gynecologic Oncology Unit, Department of Women, Children and Public Health Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; Institute of Obstetrics and Gynecology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Vittoria Rufini
- Nuclear Medicine Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; Section of Nuclear Medicine, University Department of Radiological Sciences and Hematology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Riccardo Faccini
- National Institute of Nuclear Physics (INFN), Section of Rome, Rome, Italy; Physics Department, Sapienza Università di Roma, Rome, Italy
| | | |
Collapse
|