Baumann KS, Derksen L, Witt M, Adeberg S, Zink K. The influence of different versions of FLUKA and GEANT4 on the calculation of response functions of ionization chambers in clinical proton beams.
Phys Med Biol 2023;
68:24NT01. [PMID:
37939402 DOI:
10.1088/1361-6560/ad0ad4]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 11/08/2023] [Indexed: 11/10/2023]
Abstract
Objective.To investigate the influence of different versions of the Monte Carlo codesgeant4 andflukaon the calculation of overall response functionsfQof air-filled ionization chambers in clinical proton beams.Approach. fQfactors were calculated for six plane-parallel and four cylindrical ionization chambers withgeant4 andfluka. These factors were compared to already published values that were derived using older versions of these codes.Main results.Differences infQfactors calculated with different versions of the same Monte Carlo code can be up to ∼1%. Especially forgeant4, the updated version leads to a more pronounced dependence offQon proton energy and to smallerfQfactors for high energies.Significance.Different versions of the same Monte Carlo code can lead to differences in the calculation offQfactors of up to ∼1% without changing the simulation setup, transport parameters, ionization chamber geometry modeling, or employed physics lists. These findings support the statement that the dominant contributor to the overall uncertainty of Monte Carlo calculatedfQfactors are type-B uncertainties.
Collapse