1
|
Ji Y, Zhuo Y, Li T, Lian J, Wang Z, Guo X, Kong D, Li K. MR-guided percutaneous microwave coagulation of small breast tumors. Insights Imaging 2024; 15:76. [PMID: 38499835 PMCID: PMC10948645 DOI: 10.1186/s13244-024-01645-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 02/10/2024] [Indexed: 03/20/2024] Open
Abstract
BACKGROUND To evaluate the technical success and patient safety of magnetic resonance-guided percutaneous microwave coagulation (MR-guided PMC) for breast malignancies. METHODS From May 2018 to December 2019, 26 patients with breast tumors measuring 2 cm or less were recruited to participate in a prospective, single-institution clinical study. The primary endpoint of this study was the evaluation of treatment efficacy for each patient. Histochemical staining with α-nicotinamide adenine dinucleotide and reduced (NADH)-diaphorase was used to determine cell viability following and efficacy of PMC. The complications and self-reported sensations from all patients during and after ablation were also assessed. The technical success of the PMC procedure was defined when the area of the NADH-diaphorase negative region fully covered the hematoxylin-eosin (H&E) staining region in the tumor. RESULTS All patients had a complete response to ablation with no residual carcinoma on histopathological specimen. The mean energy, ablation duration, and procedure duration per tumor were 36.0 ± 4.2 kJ, 252.9 ± 30.9 S, and 104.2 ± 13.5 min, respectively. During the ablation, 14 patients underwent prolonged ablation time, and 1 patient required adjusting of the antenna position. Eleven patients had feelings of subtle heat or swelling, and 3 patients experienced slight pain. After ablation, one patient took two painkillers because of moderate pain, and no patients had postoperative oozing or other complications after PMC. Induration around the ablation area appeared in 16 patients. CONCLUSION MR-guided PMC of small breast tumors is feasible and could be applied in clinical practice in the future. CRITICAL RELEVANCE STATEMENT MR-guided PMC of small breast tumors is feasible and could be applied in clinical practice in the future. KEY POINTS • MR-guided PMC of small breast tumors is feasible. • PMC was successfully performed for all patients. • All patients were satisfied with the final cosmetic result.
Collapse
Affiliation(s)
- Ying Ji
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Yaoyao Zhuo
- Department of Radiology, Zhongshan Hospital, Fudan University School of Medicine, Shanghai, 200000, China
| | - Ting Li
- Department of Radiology, First People's Hospital of Changzhou, Jiangsu, 213003, China
| | - Jingge Lian
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Zilin Wang
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Xinyu Guo
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 650 New Songjiang Road, Shanghai, 201620, China
| | - Dexing Kong
- School of Mathematical Sciences, Zhejiang University, Zhejiang, 310027, China
| | - Kangan Li
- Department of Radiology, Songjiang Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, 201600, China.
| |
Collapse
|
2
|
Mankertz F, Bayerl N, Gemeinhardt O, Hosten N, Kromrey ML. The Effect of Cooling Fluid Composition on Ablation Size in Hepatic Laser Ablation: A Comparative Study in an Ex Vivo Bovine Setting. Tomography 2023; 9:1638-1648. [PMID: 37736984 PMCID: PMC10514785 DOI: 10.3390/tomography9050131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 08/25/2023] [Accepted: 08/27/2023] [Indexed: 09/23/2023] Open
Abstract
PURPOSE Hyperthermic ablation is a minimally invasive mode of tumour therapy which serves as a viable alternative to surgical intervention. However, one of the major drawbacks, besides the heat sink effect and the risk of damaging adjacent organs, is limited ablation size. The use of a cooling fluid during ablation has been shown to increase the ablation volume and decrease the carbonisation rate. The aim of this study was to investigate whether the composition of the cooling fluid has an effect on ablation size and carbonisation rate during hepatic laser ablation in an ex vivo bovine setting. METHOD In this study bovine hepatic tissue was ablated in an ex vivo setting using an internally cooled laser applicator. A total of 45 tissue samples were assigned to three groups: 0.9% saline infusion (n = 15), distilled water infusion (n = 15) and a 50%/50% mixture of 0.9% saline and distilled water (n = 15). Ablation was conducted using a 1064 nm Nd:YAG laser at a wattage of 25 W and time interval of 10 min. The ablation volume and carbonisation rate were then measured and recorded through postprocedural MRI. One-way ANOVA and post-hoc testing were performed to assess the effect of the cooling fluid composition on the ablation volumes. RESULTS We found that using a mixture of saline and distilled water as a cooling fluid during hyperthermic ablation resulted in a larger ablation volume (mean ± SD: 22.64 ± 0.99 cm3) when compared to saline infusion (21.08 ± 1.11 cm3) or distilled water infusion (20.92 ± 0.92 cm3). This difference was highly significant (p < 0.001). There was no significant difference in ablation size between the saline group and the distilled water group. The highest carbonisation rate occurred in the saline group (12/15), followed by the mixed infusion group (3/15) and the distilled water group (1/15). CONCLUSIONS The results of this study suggest that cooling fluid composition during hepatic laser ablation affects ablation volume in an ex vivo bovine setting. There was no statistically significant difference when comparing ablation volumes during saline infusion and distilled water infusion, but the carbonisation rate was significantly higher when using saline. The combination of saline and distilled water in a 50%/50% mixture as cooling fluid appears to be an auspicious alternative, as ablation volumes created with it are larger when compared to saline and distilled water alone, while carbonisation rate remains low. This might improve patient outcome as well as patient eligibility for hyperthermic ablation.
Collapse
Affiliation(s)
- Fiona Mankertz
- Institute for Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, 17475 Greifswald, Germany
| | - Nadine Bayerl
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Ole Gemeinhardt
- Department of Radiology, Charité—Universitätsmedizin Berlin, 10117 Berlin, Germany
| | - Norbert Hosten
- Institute for Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, 17475 Greifswald, Germany
| | - Marie-Luise Kromrey
- Institute for Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, 17475 Greifswald, Germany
| |
Collapse
|
3
|
Tehrani MHH, Soltani M, Kashkooli FM, Raahemifar K. Use of microwave ablation for thermal treatment of solid tumors with different shapes and sizes-A computational approach. PLoS One 2020; 15:e0233219. [PMID: 32542034 PMCID: PMC7295236 DOI: 10.1371/journal.pone.0233219] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 04/30/2020] [Indexed: 12/11/2022] Open
Abstract
Microwave Ablation (MWA) is one of the most recent developments in the field of thermal therapy. This approach is an effective method for thermal tumor ablation by increasing the temperature above the normal physiological threshold to kill cancer cells with minimum side effects to surrounding organs due to rapid heat dispersive tissues. In the present study, the effects of the shape and size of the tumor on MWA are investigated. To obtain the temperature gradient, coupled bio-heat and electromagnetic equations are solved using a three-dimensional finite element method (FEM). To extract cellular response at different temperatures and times, the three-state mathematical model was employed to achieve the ablation zone size. Results show that treatment of larger tumors is more difficult than that of smaller ones. By doubling the diameter of the tumor, the percentage of dead cancer cells is reduced by 20%. For a spherical tumor smaller than 2 cm, applying 50 W input power compared to 25 W has no significant effects on treatment efficiency and only increases the risk of damage to adjacent tissues. However, for tumors larger than 2 cm, it can increase the ablation zone up to 21%. In the spherical and oblate tumors, the mean percentage of dead cells at 6 GHz is nearly 30% higher than that at 2.45GHz, but for prolate tumors, treatment efficacy is reduced by 10% at a higher frequency. Moreover, the distance between two slots in the coaxial double slot antenna is modified based on the best treatment of prolate tumors. The findings of this study can be used to choose the optimum frequency and the best antenna design according to the shape and size of the tumor.
Collapse
Affiliation(s)
- Masoud H. H. Tehrani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | - M. Soltani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
- Advanced Bioengineering Initiative Center, Computational Medicine Center, K. N. Toosi University of Technology, Tehran, Iran
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, Canada
- Centre for Biotechnology and Bioengineering (CBB), University of Waterloo, Waterloo, ON, Canada
- Cancer Biology Research Center, Cancer Institute of Iran, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Kaamran Raahemifar
- Electrical and Computer Engineering Department, Sultan Qaboos University, Muscat, Sultanate of Oman
- Chemical Engineering Department, University of Waterloo, Waterloo, ON, Canada
- College of Information Sciences and Technology (IST), Data Science and Artificial Intelligence Program, Penn State University, State College, Pennsylvania, PA, United States of America
| |
Collapse
|
4
|
Krokidis ME, Orsi F, Katsanos K, Helmberger T, Adam A. CIRSE Guidelines on Percutaneous Ablation of Small Renal Cell Carcinoma. Cardiovasc Intervent Radiol 2016; 40:177-191. [DOI: 10.1007/s00270-016-1531-y] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2016] [Accepted: 12/01/2016] [Indexed: 01/09/2023]
|
5
|
Poulou LS, Botsa E, Thanou I, Ziakas PD, Thanos L. Percutaneous microwave ablation vs radiofrequency ablation in the treatment of hepatocellular carcinoma. World J Hepatol 2015; 7:1054-1063. [PMID: 26052394 PMCID: PMC4450182 DOI: 10.4254/wjh.v7.i8.1054] [Citation(s) in RCA: 249] [Impact Index Per Article: 24.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 10/22/2014] [Accepted: 02/11/2015] [Indexed: 02/06/2023] Open
Abstract
Hepatocellular cancer ranks fifth among cancers and is related to chronic viral hepatitis, alcohol abuse, steatohepatitis and liver autoimmunity. Surgical resection and orthotopic liver transplantation have curative potential, but fewer than 20% of patients are suitable candidates. Interventional treatments are offered to the vast majority of patients. Radiofrequency (RFA) and microwave ablation (MWA) are among the therapeutic modalities, with similar indications which include the presence of up to three lesions, smaller than 3 cm in size, and the absence of extrahepatic disease. The therapeutic effect of both methods relies on thermal injury, but MWA uses an electromagnetic field as opposed to electrical current used in RFA. Unlike MWA, the effect of RFA is partially limited by the heat-sink effect and increased impedance of the ablated tissue. Compared with RFA, MWA attains a more predictable ablation zone, permits simultaneous treatment of multiple lesions, and achieves larger coagulation volumes in a shorter procedural time. Major complications of both methods are comparable and infrequent (approximately 2%-3%), and they include haemorrhage, infection/abscess, visceral organ injury, liver failure, and pneumothorax. RFA may incur the additional complication of skin burns. Nevertheless, there is no compelling evidence for differences in clinical outcomes, including local recurrence rates and survival.
Collapse
|
6
|
Horn JC, Patel RS, Kim E, Nowakowski FS, Lookstein RA, Fischman AM. Percutaneous microwave ablation of renal tumors using a gas-cooled 2.4-GHz probe: technique and initial results. J Vasc Interv Radiol 2014; 25:448-53. [PMID: 24581469 DOI: 10.1016/j.jvir.2013.10.029] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2013] [Revised: 10/16/2013] [Accepted: 10/17/2013] [Indexed: 12/22/2022] Open
Abstract
The feasibility, safety, and preliminary effectiveness of microwave ablation (MWA) in the treatment of renal tumors using a high-powered, carbon dioxide-cooled probe were evaluated. There were 15 tumors treated in 14 patients. Computed tomography was performed immediately after MWA, and follow-up imaging was performed to evaluate for recurrence. Immediate technical effectiveness was 100%. One complication involved the formation of a renal artery pseudoaneurysm. At follow-up (mean interval, 12.5 wk) evaluation, 14 of 15 (93.3%) tumors demonstrated complete necrosis. MWA is a safe, effective treatment modality; larger studies are warranted to demonstrate long-term oncologic outcomes.
Collapse
Affiliation(s)
- Jeremy C Horn
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Medical Center, One Gustave L. Levy Place, Box 1234, New York, NY 10029
| | - Rahul S Patel
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Medical Center, One Gustave L. Levy Place, Box 1234, New York, NY 10029
| | - Edward Kim
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Medical Center, One Gustave L. Levy Place, Box 1234, New York, NY 10029
| | - F Scott Nowakowski
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Medical Center, One Gustave L. Levy Place, Box 1234, New York, NY 10029
| | - Robert A Lookstein
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Medical Center, One Gustave L. Levy Place, Box 1234, New York, NY 10029
| | - Aaron M Fischman
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Medical Center, One Gustave L. Levy Place, Box 1234, New York, NY 10029.
| |
Collapse
|
7
|
Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: An in vivo comparison. Eur J Radiol 2013; 82:e350-5. [DOI: 10.1016/j.ejrad.2013.02.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2012] [Revised: 02/07/2013] [Accepted: 02/11/2013] [Indexed: 02/08/2023]
|
8
|
High-powered gas-cooled microwave ablation: shaft cooling creates an effective stick function without altering the ablation zone. AJR Am J Roentgenol 2012; 198:W260-5. [PMID: 22358023 DOI: 10.2214/ajr.11.6503] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE The purpose of our study was to validate the ability of a new gas-cooled microwave device to secure antennas into tissue before ablation via shaft cooling and to verify that such cooling does not compromise the intended ablation. MATERIALS AND METHODS The force required to extract several types of applicators from ex vivo bovine liver before and after ablation was measured. Six groups were compared: cooled needle and multitined radiofrequency electrodes, secured and unsecured cryoprobes, and gas-cooled microwave antennas (n = 6 each). Ablations were next created in in vivo porcine livers for 2 and 10 minutes (n = 6 each) using the gas-cooled microwave system at 140 W. Extraction force was again measured before and after ablation and compared between groups using analysis of variance with post hoc Student t tests. Histologic analysis of the ablation zone was performed to evaluate cellular necrosis along the antenna shaft. RESULTS Ex vivo, the secured cryoprobe and microwave antenna required significantly more force to remove than unsecured radiofrequency, cryoprobe, and microwave applicators (p < 0.05, all comparisons). The multitined radiofrequency electrode and cooled radiofrequency electrode required significantly more force to remove after ablation than before ablation (p = 0.006 and 0.02, respectively). In vivo, the secured antenna required significantly more force to remove before ablation than after ablation at both 2 (p < 0.0001) and 10 minutes (p < 0.0001). There was no histologic evidence of cell preservation along the antenna shaft. CONCLUSION The gas cooling used in this microwave device can effectively secure antennas into tissue without altering ablation shape or reducing the intended thermal damage.
Collapse
|
9
|
Zhou W, Zha X, Liu X, Ding Q, Chen L, Ni Y, Zhang Y, Xu Y, Chen L, Zhao Y, Wang S. US-guided percutaneous microwave coagulation of small breast cancers: a clinical study. Radiology 2012; 263:364-73. [PMID: 22438362 DOI: 10.1148/radiol.12111901] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE To determine the feasibility of percutaneous microwave coagulation (PMC) for the treatment of small solitary breast cancers. MATERIALS AND METHODS With approval of the institutional ethics committee and written informed consent, 41 patients with core-needle-biopsy-proved breast cancers 3.0 cm or less in diameter accessed by using ultrasonography (US) were recruited. US-guided PMC was performed with general anesthesia, followed immediately by mastectomy. Histochemical staining with α-nicotinamide adenine dinucleotide, reduced (NADH)-diaphorase was used to determine cell viability and the extent of PMC lesions. RESULTS The mean tumor volume was 5.26 cm(3) ± 3.80 (standard deviation), with a range from 0.09 to 14.14 cm(3). PMC was successfully performed in all cases, with complete tumor ablation as assessed by using US. The mean time to reach complete ablation was 4.48 minutes, ranging from 3 to 10 minutes. With microscopic examination, 37 of 41 cases (90%; 95% confidence interval [CI]: 76.9%, 97.3%) showed complete tumor coagulation, as observed by using α-NADH-diaphorase staining. Of 38 cases diagnosed with invasive ductal carcinoma, 36 cases (95%; 95% CI: 82.3%, 99.4%) showed complete tumor coagulation. Slight thermal injuries to the skin and pectoralis major muscle, which proved reversible, were found in three cases. CONCLUSION US-guided PMC of small solitary breast cancers is feasible. Nevertheless, larger-scale clinical trials are still needed to validate PMC for adoption into a standard clinical practice.
Collapse
Affiliation(s)
- Wenbin Zhou
- Department of Breast Surgery and Pathology, Nanjing Medical University, Nanjing, China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|