1
|
El-Shahawi MS, Alwael H, Alsibaai AA, Hamza A, Algethami FK, Alshareef FM, El-Khouly SH, Eweda N. Sorption Characteristics and Chromatographic Separation of 90Y 3+ from 90Sr 2+ from Aqueous Media by Chelex-100 (Anion Ion Exchange) Packed Column. Int J Anal Chem 2024; 2024:6232381. [PMID: 38770043 PMCID: PMC11105960 DOI: 10.1155/2024/6232381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/29/2024] [Accepted: 04/09/2024] [Indexed: 05/22/2024] Open
Abstract
There is growing demand for separation of 90Y carrier free from 90Sr coexisting to produce high purity 90Y essential for radiopharmaceutical uses. Thus, in this context the sorption profiles of Y3+ and Sr2+ from aqueous solutions containing diethylenetriaminepenta acetic acid (DTPA), ethylenediaminetetra-acetic acid (EDTA), acetic acid, citric acid, or NaCl onto Chelex-100 (anion ion exchange) solid sorbent were critically studied for developing an efficient and low-cost methodology for selective separation of Y3+ from Sr2+ ions (1.0 × 10-5 M). Batch experiments displayed relative chemical extraction percentage (98 ± 5.4%) of Y3+ from aqueous acetic acid solution onto Chelex-100 (anion ion exchanger), whereas Sr2+ species showed no sorption. Hence, a selective separation of Y3+ from its parent 90Sr2+ has been established based upon percolation of the aqueous solution of Y3+ and Sr2+ ions containing acetic acid at pH 1-2 through Chelex-100 sorbent packed column at a 2 mL min-1 flow rate. Y3+ species were retained quantitatively while Sr2+ ions were not sorbed and passed through the sorbent packed column without extraction. The sorbed Y3+ species were then recovered from the sorbent packed column with HNO3 (1.0 M) at a 1.0 mL min-1 flow rate. A dual extraction mechanism comprising absorption associated to "weak-base anion exchanger" and "solvent extraction" of Y3+ as (YCl6)3- and an extra part for "surface adsorption" of Y3+ by the sorbent is proposed. The established method was validated by measuring the radiochemical (99.2 ± 2 1%), radionuclide purity and retardation factor (Rf = 10.0 ± 0.1 cm) of 90Y3+ recovered in the eluate. Ultimately, the sorbent packed column also presented high stability for reusing 2-3 cycles without drop in its efficiency (±5%) towards Y3+ uptake and relative chemical recovery. A proposed flow sheet describing the analytical procedures for the separation of 90Y3+ from 90Sr2+ using chelating Chelex 100 (anion exchange) packed column is also included.
Collapse
Affiliation(s)
- Mohammad S. El-Shahawi
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Hassan Alwael
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Abdulaziz A. Alsibaai
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Abdelgany Hamza
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Faisal K. Algethami
- Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), P.O. Box 90950, Riyadh 11623, Saudi Arabia
| | - Fatmah M. Alshareef
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Sanaa H. El-Khouly
- Department of Production of Isotopes and Generators, Atomic Energy Authority, Cairo, Egypt
| | - Neven Eweda
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| |
Collapse
|
2
|
Levillain H, Bagni O, Deroose CM, Dieudonné A, Gnesin S, Grosser OS, Kappadath SC, Kennedy A, Kokabi N, Liu DM, Madoff DC, Mahvash A, Martinez de la Cuesta A, Ng DCE, Paprottka PM, Pettinato C, Rodríguez-Fraile M, Salem R, Sangro B, Strigari L, Sze DY, de Wit van der Veen BJ, Flamen P. International recommendations for personalised selective internal radiation therapy of primary and metastatic liver diseases with yttrium-90 resin microspheres. Eur J Nucl Med Mol Imaging 2021; 48:1570-1584. [PMID: 33433699 PMCID: PMC8113219 DOI: 10.1007/s00259-020-05163-5] [Citation(s) in RCA: 150] [Impact Index Per Article: 37.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 12/08/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. METHODS A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%-79%, no agreement ≤ 49%). RESULTS Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100-120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). CONCLUSION Practitioners are encouraged to work towards adoption of these recommendations.
Collapse
Affiliation(s)
- Hugo Levillain
- Department of Nuclear Medicine, Jules Bordet Institute, Université Libre de Bruxelles, Rue Héger-Bordet 1, B-1000, Brussels, Belgium.
| | - Oreste Bagni
- Nuclear Medicine Unit, Santa Maria Goretti Hospital, Latina, Italy
| | - Christophe M Deroose
- Nuclear Medicine, University Hospitals Leuven and Nuclear Medicine & Molecular Imaging, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Arnaud Dieudonné
- Department of Nuclear Medicine, Hôpital Beaujon, AP-HP.Nord, DMU DREAM and Inserm U1149, Clichy, France
| | - Silvano Gnesin
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Oliver S Grosser
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Germany and Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
| | - S Cheenu Kappadath
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | | | - Nima Kokabi
- Division of Interventional Radiology and Image Guided Medicine, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - David M Liu
- Department of Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada
| | - David C Madoff
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | | | - David C E Ng
- Department of Nuclear Medicine and Molecular Imaging, Singapore General Hospital, Singapore, Singapore
| | - Philipp M Paprottka
- Department of Interventional Radiology, Technical University Munich, Munich, Germany
| | - Cinzia Pettinato
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | | | - Riad Salem
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | - Bruno Sangro
- Clinica Universidad de Navarra-IDISNA and CIBEREHD, Pamplona, Spain
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Daniel Y Sze
- Department of Interventional Radiology, Stanford University School of Medicine, Palo Alto, CA, USA
| | | | - Patrick Flamen
- Department of Nuclear Medicine, Jules Bordet Institute, Université Libre de Bruxelles, Rue Héger-Bordet 1, B-1000, Brussels, Belgium
| |
Collapse
|
3
|
|
4
|
Pasoglou V, Michoux N, Larbi A, Van Nieuwenhove S, Lecouvet F. Whole Body MRI and oncology: recent major advances. Br J Radiol 2018; 91:20170664. [PMID: 29334236 DOI: 10.1259/bjr.20170664] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
MRI is a very attractive approach for tumour detection and oncological staging with its absence of ionizing radiation, high soft tissue contrast and spatial resolution. Less than 10 years ago the use of Whole Body MRI (WB-MRI) protocols was uncommon due to many limitations, such as the forbidding acquisition times and limited availability. This decade has marked substantial progress in WB-MRI protocols. This very promising technique is rapidly arising from the research world and is becoming a commonly used examination for tumour detection due to recent technological developments and validation of WB-MRI by multiple studies and consensus papers. As a result, WB-MRI is progressively proposed by radiologists as an efficient examination for an expanding range of indications. As the spectrum of its uses becomes wider, radiologists will soon be confronted with the challenges of this technique and be urged to be trained in order to accurately read and report these examinations. The aim of this review is to summarize the validated indications of WB-MRI and present an overview of its most recent advances. This paper will briefly discuss how this examination is performed and which are the recommended sequences along with the future perspectives in the field.
Collapse
Affiliation(s)
- Vassiliki Pasoglou
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| | - Nicolas Michoux
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| | - Ahmed Larbi
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium.,2 Department of Radiology, Nimes University Hospital , Nimes , France
| | - Sandy Van Nieuwenhove
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| | - Frédéric Lecouvet
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| |
Collapse
|
5
|
Pasoglou V, Michoux N, Larbi A, Van Nieuwenhove S, Lecouvet F. Whole Body MRI and oncology: recent major advances. Br J Radiol 2018. [PMID: 29334236 DOI: 10.1259/bjr.20170664%0a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
MRI is a very attractive approach for tumour detection and oncological staging with its absence of ionizing radiation, high soft tissue contrast and spatial resolution. Less than 10 years ago the use of Whole Body MRI (WB-MRI) protocols was uncommon due to many limitations, such as the forbidding acquisition times and limited availability. This decade has marked substantial progress in WB-MRI protocols. This very promising technique is rapidly arising from the research world and is becoming a commonly used examination for tumour detection due to recent technological developments and validation of WB-MRI by multiple studies and consensus papers. As a result, WB-MRI is progressively proposed by radiologists as an efficient examination for an expanding range of indications. As the spectrum of its uses becomes wider, radiologists will soon be confronted with the challenges of this technique and be urged to be trained in order to accurately read and report these examinations. The aim of this review is to summarize the validated indications of WB-MRI and present an overview of its most recent advances. This paper will briefly discuss how this examination is performed and which are the recommended sequences along with the future perspectives in the field.
Collapse
Affiliation(s)
- Vassiliki Pasoglou
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| | - Nicolas Michoux
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| | - Ahmed Larbi
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium.,2 Department of Radiology, Nimes University Hospital , Nimes , France
| | - Sandy Van Nieuwenhove
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| | - Frédéric Lecouvet
- 1 Department of Radiology, Centre du Cancer et Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain , Brussels , Belgium
| |
Collapse
|
6
|
The role of 18F-FDG-PET and PET/CT in patients with colorectal liver metastases undergoing selective internal radiation therapy with yttrium-90: a first evidence-based review. ScientificWorldJournal 2014; 2014:879469. [PMID: 24672385 PMCID: PMC3929576 DOI: 10.1155/2014/879469] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 10/19/2013] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To provide a first evidence-based review of the literature on the role of fluorine-18-fluorodeoxyglucose positron emission tomography and positron emission tomography/computed tomography (FDG-PET and PET/CT) in patients with colorectal liver metastases (CRLM) undergoing selective internal radiation therapy (SIRT) with yttrium-90 ((90)Y) microspheres. METHODS A comprehensive computer literature search was conducted to find relevant published articles on whole-body FDG-PET or PET/CT in patients with CRLM undergoing SIRT. RESULTS We identified 19 studies including 833 patients with CRLM undergoing SIRT. The role of FDG-PET or PET/CT was analysed in treatment planning, treatment response evaluation, and as prognostic tool. CONCLUSION FDG-PET and PET/CT provide additional information in treatment evaluation of CRLM patients treated with SIRT and may have a role in treatment planning and patient selection. FDG-PET/CT is emerging as good prognostic tool in these patients.
Collapse
|
7
|
Madhuranthakam AJ, Lee KS, Yassin A, Brittain JH, Pedrosa I, Rofsky NM, Alsop DC. Improved short tau inversion recovery (iSTIR) for increased tumor conspicuity in the abdomen. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 27:245-55. [PMID: 24052241 DOI: 10.1007/s10334-013-0410-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 09/05/2013] [Accepted: 09/09/2013] [Indexed: 01/09/2023]
Abstract
OBJECT To develop an improved short tau inversion recovery (iSTIR) technique with simultaneous suppression of fat, blood vessels and fluid to increase tumor conspicuity in the abdomen for cancer screening. MATERIALS AND METHODS An adiabatic spectrally selective inversion pulse was used for fat suppression to overcome the reduced signal to noise ratio associated with chemically non-selective inversion pulse of STIR. A motion-sensitizing driven equilibrium was used for blood vessel suppression and a dual-echo single-shot fast spin echo acquisition was used for fluid suppression. The technique was optimized on four normal subjects and later tested on five patients referred for metastatic tumor evaluation. RESULTS A velocity encoding of 2 cm/s achieved effective blood suppression even in small vessels. Subtraction of two images (one with 60 ms and the other with 280 ms echo time) acquired in the same echo train achieved excellent fluid suppression (>70% reduction). Simultaneous suppression of fat, blood vessels and fluid improved the tumor conspicuity compared to corresponding fat-suppressed (STIR) image. CONCLUSION This technique generated two complementary images from a single scan: one that is equivalent to a STIR image and the other that qualitatively resembles a diffusion-weighted image and may have potential for magnetic resonance imaging cancer screening.
Collapse
|
8
|
Comparison between whole-body MRI and Fluorine-18-Fluorodeoxyglucose PET or PET/CT in oncology: a systematic review. Radiol Oncol 2013; 47:206-18. [PMID: 24133384 PMCID: PMC3794875 DOI: 10.2478/raon-2013-0007] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2012] [Accepted: 10/23/2012] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND The aim of the article is to systematically review published data about the comparison between positron emission tomography (PET) or PET/computed tomography (PET/CT) using Fluorine-18-Fluorodeoxyglucose (FDG) and whole-body magnetic resonance imaging (WB-MRI) in patients with different tumours. METHODS A comprehensive literature search of studies published in PubMed/MEDLINE, Scopus and Embase databases through April 2012 and regarding the comparison between FDG-PET or PET/CT and WB-MRI in patients with various tumours was carried out. RESULTS Forty-four articles comprising 2287 patients were retrieved in full-text version, included and discussed in this systematic review. Several articles evaluated mixed tumours with both diagnostic methods. Concerning the specific tumour types, more evidence exists for lymphomas, bone tumours, head and neck tumours and lung tumours, whereas there is less evidence for other tumour types. CONCLUSIONS Overall, based on the literature findings, WB-MRI seems to be a valid alternative method compared to PET/CT in oncology. Further larger prospective studies and in particular cost-effectiveness analysis comparing these two whole-body imaging techniques are needed to better assess the role of WB-MRI compared to FDG-PET or PET/CT in specific tumour types.
Collapse
|
9
|
El-Shahawi MS, Kadi MW, El-Khouly SH, Abd El-Mohty A, Saad SM, Eweda NEA. Retention profile and selective separation of 90Y from 89Sr using zirconium-vanadate gel packed column. J Radioanal Nucl Chem 2012. [DOI: 10.1007/s10967-012-2262-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|