1
|
Liu K, Chen C, Shen T, Wen X, Zeng M, Xu P. Multiple b value diffusion-weighted MRI of liver: A novel respiratory frequency-modulated continuous-wave radar-trigger technique and comparison with free-breathing technique. Magn Reson Imaging 2025; 117:110312. [PMID: 39694121 DOI: 10.1016/j.mri.2024.110312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 12/15/2024] [Accepted: 12/15/2024] [Indexed: 12/20/2024]
Abstract
OBJECTIVE The aim of this study was to evaluate a novel respiratory frequency-modulated continuous-wave radar-trigger (FT) technique for multiple -b-value diffusion-weighted imaging (DWI) of liver and compare it with conventional free breathing (FB) DWI technique. MATERIAL AND METHODS 39 patients with focal liver lesions underwent both frequency-modulated continuous-wave radar-trigger (FT) and conventional free-breathing (FB) multi-b-value diffusion-weighted imaging (DWI,b = 0,50,400,800 s/mm2). Two abdominal radiologists independently assessed the quality of liver DWI images obtained using both techniques, measured and compared liver signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at different b-values, as well as apparent diffusion coefficient (ADC) values calculated from all b-values. RESULTS In terms of image quality, the FT technique is superior to the conventional FB technique, with overall image quality scores (Reader 1, 3.56 ± 0.50 and Reader 2, 3.59 ± 0.55)vs (Reader 1, 2.90 ± 0.75 and Reader 2, 2.97 ± 0.71), respectively. The liver SNR (at b-values of 50,400,and 800 s/mm2) obtained by FT was (138.5 ± 43.48, 96.67 ± 31.95, 71.54 ± 22.03), respectively, which was significantly higher than that obtained by conventional FB (110.90 ± 39.28, 80.86 ± 29.13, 60.43 ± 18.61, P < 0.05). The lesion CNR with FT was significantly higher than that with conventional FB (258.99 ± 151.38 vs 174.60 ± 99.90; 164.56 ± 87.25 vs 111.12 ± 42.43; 118.83 ± 68.76 vs 76.01 ± 35.48, P < 0.001). There was no significant difference in ADC values of liver and lesions between the two techniques: ADCliver-L and ADCliver-R: (FT 1479.3 ± 270.0 vs FB 1529.3 ± 275.5 and FT 1219.6 ± 127.4 vs FB 1248.7 ± 168.2, P > 0.05); ADC lesion:FT(969.0 ± 261.3) vs FB (1017.5 ± 240.4, P > 0.05). CONCLUSION For multi-b-value liver diffusion-weighted imaging, FT technique has higher image quality and better lesion visibility than conventional FB technique and there is no significant difference in ADC values of liver and lesions between the two techniques.
Collapse
Affiliation(s)
- Kai Liu
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, China.
| | - Caizhong Chen
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, China.
| | - Tingting Shen
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, China.
| | - Xixi Wen
- Shanghai United Imaging Healthcare Co., Ltd., Shanghai, China.
| | - Mengsu Zeng
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, China
| | - Pengju Xu
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, China.
| |
Collapse
|
2
|
Reithmeier B, Laun FB, Führes T, Uder M, Bickelhaupt S, Saake M. Relevance of lesion size in navigator-triggered and free-breathing diffusion-weighted liver MRI. Eur Radiol 2025; 35:2106-2115. [PMID: 39287825 PMCID: PMC11913969 DOI: 10.1007/s00330-024-11063-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 07/14/2024] [Accepted: 08/21/2024] [Indexed: 09/19/2024]
Abstract
OBJECTIVES The purpose of this study was to investigate the relevance of focal liver lesions (FLL) size for lesion detection comparing navigator triggering (TRIG) to free breathing (FB) liver Diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHOD Patients with known or suspected FLL were prospectively (registry number 276_19 B) included from October to December 2019 in this study, out of which 32 had liver lesions. Echo planar spin-echo DWI data both with TRIG and FB were with approximately constant acquisition times acquired at 1.5 T. Lesions were segmented in the b = 800 s/mm² images in both the TRIG and FB images. The lesion size, location (liver segment), liver lesion visibility, as well as contrast-to-noise ratio (CNR) were recorded. The CNR was assessed with the Wilcoxon-Mann-Whitney test and the number of visible lesions with the Fisher test. RESULTS Data from 43 patients (22 female) were analyzed. The mean patient age was 58 ± 14 years. A total of 885 FLL (Ntotal) were segmented. Among these, 811 lesions (Nboth) were detected with TRIG and FB, 65 lesions exclusively with TRIG (NTRIG_Only), and nine exclusively in FB (NFB_Only). The largest additional lesion in TRIG/FB had a diameter of 10.4 mm/7.6 mm. The number of additional lesions detected with TRIG decreased with size. Among all lesions ≤ 4.7 mm, the relative number of additional lesions was 15.6%. Additional lesions were found in all liver segments with TRIG. In the left liver lobe, the relative proportion was 9.2%, and in the right liver lobe 5.4%. CNR and visibility were significantly higher in TRIG than in FB (p < 0.001). In relation to size, the difference is significant in terms of visibility and CNR for lesion diameters ≤ 8 mm. CONCLUSION Respiration triggering can improve the detection of small liver lesions with diameters up to approx. 1 cm in the whole liver. KEY POINTS Question Can respiration triggering (TRIG) improve the detection of small FLL compared to FB diffusion-weighted imaging? Findings Among 885 segmented FLL, TRIG was superior to FB for lesions smaller than 8 mm and had improved CNR and visibility. Clinical relevance Diffusion-weighted magnetic resonance imaging is used for the detection of focal liver lesions and image quality is influenced by breathing motion. Navigator triggering becomes more important for smaller lesions, and seems recommendable for the detection of small focal liver lesions.
Collapse
Affiliation(s)
- Bianca Reithmeier
- Institut für Radiologie, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland.
| | - Frederik B Laun
- Institut für Radiologie, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
| | - Tobit Führes
- Institut für Radiologie, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
| | - Michael Uder
- Institut für Radiologie, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
| | - Sebastian Bickelhaupt
- Institut für Radiologie, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
| | - Marc Saake
- Institut für Radiologie, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
| |
Collapse
|
3
|
Liang X, Bi Z, Yang C, Sheng R, Xia X, Zhang Z, Dai Y, Zeng M. Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study. Front Oncol 2022; 12:918173. [PMID: 35719930 PMCID: PMC9200370 DOI: 10.3389/fonc.2022.918173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 05/03/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study is to evaluate the performance of free-breathing liver MRI with a novel respiratory frequency-modulated continuous-wave radar-trigger (FT) technique on T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) for both healthy volunteers and patients in comparison to navigator-trigger (NT) and belt-trigger (BT) techniques. Methods In this prospective study, 17 healthy volunteers and 23 patients with known or suspected liver diseases were enrolled. Six sequences (T2WI and DWI with FT, NT, and BT techniques) were performed in each subject. Quantitative evaluation and qualitative assessment were analyzed by two radiologists. Overall image quality, blurring, motion artifacts, and liver edge delineations were rated on a 4-point Likert scale. The liver and lesion signal-to-noise ratio (SNR), the lesion-to-liver contrast-to-noise ratio (CNR), as well as the apparent diffusion coefficient (ADC) value were quantitatively calculated. Results For volunteers, there were no significant differences in the image quality Likert scores and quantitative parameters on T2WI and DWI with three respiratory-trigger techniques. For patients, NT was superior to other techniques for image quality on T2WI; conversely, little difference was found on DWI in qualitative assessment. The mean SNR of the liver on T2WI and DWI with BT, NT, and FT techniques was similar in patients, which is in line with volunteers. FT performed better in terms of higher SNR (705.13 ± 434.80) and higher CNR (504.41 ± 400.69) on DWI at b50 compared with BT (SNR: 651.83 ± 401.16; CNR:429.24 ± 404.11) and NT (SNR: 639.41 ± 407.98; CNR: 420.64 ± 416.61) (p < 0.05). The mean ADC values of the liver and lesion with different techniques in both volunteers and patients showed non-significant difference. Conclusion For volunteers, the performance of T2WI as well as DWI with three respiratory-trigger techniques was similarly good. As for patients, FT-DWI is superior to BT and NT techniques in terms of higher lesion SNR and CNR at b50.
Collapse
Affiliation(s)
- Xinyue Liang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Zhenghong Bi
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Chun Yang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Ruofan Sheng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xinyuan Xia
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Zheng Zhang
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Mengsu Zeng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
4
|
Saake M, Seuß H, Riexinger A, Bickelhaupt S, Hammon M, Uder M, Laun FB. Image Quality and Detection of Small Focal Liver Lesions in Diffusion-Weighted Imaging: Comparison of Navigator Tracking and Free-Breathing Acquisition. Invest Radiol 2021; 56:579-590. [PMID: 33813572 DOI: 10.1097/rli.0000000000000776] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The aim of this study was to compare intraindividual diffusion-weighted imaging (DWI) of the liver acquired with free breathing (FB) versus navigator triggering (NT) for assessing small focal liver lesions (FLLs) in noncirrhotic patients. MATERIALS AND METHODS Patients with known or suspected multiple FLLs were prospectively included, and spin-echo echo-planar DWI with NT and FB acquisition was performed (b-values, 50 and 800 s/mm2 [b50 and b800]). NT and FB DWI sequences with similar acquisitions times were used. Liver and lesion signal-to-noise ratios were measured at b800. The DWI scans were analyzed independently by 2 readers. Liver edge delineation, presence of stair-step artifacts, vessel sharpness, severity of cardiac motion artifacts, overall image quality, and lesion conspicuity were rated with 5-point Likert scales. Small and large FLLs (ie, <1 cm or ≥1 cm) were rated separately for lesion conspicuity. The FLL detectability was estimated by comparing the number of lesions visible with FB to those visible with NT. RESULTS Forty-three patients were included in the study. The FB acquisition performed better in terms of severity of cardiac motion artifacts. The NT performed better in terms of liver edge delineation and vessel sharpness. Little difference was found for stair-step artifact, overall image quality, and conspicuity of large FLL, whereas the conspicuity of small FLL was better for NT. For small FLL, both readers found more lesions with NT in 11 cases at b800. For large FLL, this effect was much less pronounced (1 case at b800 reported by 1 of the readers). The mean liver and lesion signal-to-noise ratios were 16.8/41.5 and 19.8/38.4 for NT/FB, respectively. CONCLUSIONS Small FLL detection is better with NT. Large FLL detection by FB and NT is similarly good. We conclude that NT should be used.
Collapse
Affiliation(s)
- Marc Saake
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | | | - Andreas Riexinger
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Sebastian Bickelhaupt
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Matthias Hammon
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Michael Uder
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| | - Frederik B Laun
- From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen
| |
Collapse
|
5
|
Riexinger A, Laun FB, Bickelhaupt S, Seuß H, Uder M, Hensel B, Saake M. On the dependence of the cardiac motion artifact on the breathing cycle in liver diffusion-weighted imaging. PLoS One 2020; 15:e0239743. [PMID: 33002028 PMCID: PMC7529231 DOI: 10.1371/journal.pone.0239743] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 09/11/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose The purpose of this study was to investigate whether the cardiac motion artifact that regularly appears in diffusion-weighted imaging of the left liver lobe might be reduced by acquiring images in inspiration, when the coupling between heart and liver might be minimal. Materials and methods 43 patients with known or suspected focal liver lesions were examined at 1.5 T with breath hold acquisition, once in inspiration and once in expiration. Data were acquired with a diffusion-weighted echo planar imaging sequence and two b-values (b50 = 50 s/mm² and b800 = 800 s/mm²). The severity of the cardiac motion artifact in the left liver lobe was rated by two experienced radiologists for both b-values with a 5 point Likert scale. Additionally, the normalized signal S(b800)/S(b50) in the left liver lobe was computed. The Wilcoxon signed-rank test was used comparing the scores of the two readers obtained in inspiration and expiration, and to compare the normalized signal in inspiration and expiration. Results The normalized signal in inspiration was slightly higher than in expiration (0.349±0.077 vs 0.336±0.058), which would indicate a slight reduction of the cardiac motion artifact, but this difference was not significant (p = 0.24). In the qualitative evaluation, the readers did not observe a significant difference for b50 (reader 1: p = 0.61; reader 2: p = 0.18). For b800, reader 1 observed a significant difference of small effect size favouring expiration (p = 0.03 with a difference of mean Likert scores of 0.27), while reader 2 observed no significant difference (p = 0.62). Conclusion Acquiring the data in inspiration does not lead to a markedly reduced cardiac motion artifact in diffusion-weighted imaging of the left liver lobe and is in this regard not to be preferred over acquiring the data in expiration.
Collapse
Affiliation(s)
- Andreas Riexinger
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
- * E-mail:
| | | | | | - Hannes Seuß
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| | - Bernhard Hensel
- Center for Medical Physics and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Marc Saake
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
6
|
Yacoub JH, Elsayes KM, Fowler KJ, Hecht EM, Mitchell DG, Santillan C, Szklaruk J. Pitfalls in liver MRI: Technical approach to avoiding misdiagnosis and improving image quality. J Magn Reson Imaging 2018; 49:41-58. [DOI: 10.1002/jmri.26343] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 08/29/2018] [Accepted: 08/30/2018] [Indexed: 12/27/2022] Open
Affiliation(s)
- Joseph H Yacoub
- Department of Radiology; Medstar Georgetown University Hospital; Washington DC USA
| | - Khaled M. Elsayes
- Department of Diagnostic Radiology; University of Texas MD Anderson Cancer Center; Houston Texas USA
| | - Kathryn J. Fowler
- University of California San Diego Health System, Department of Radiology; San Diego California USA
| | - Elizabeth M. Hecht
- Department of Radiology; New York Presbyterian-Columbia University Medical Center; New York New York
| | - Donald G. Mitchell
- Department of Radiology; Thomas Jefferson University; Philadelphia Pennsylvania USA
| | - Cynthia Santillan
- Liver Imaging Group; University of California San Diego; San Diego California USA
| | - Janio Szklaruk
- Department of Diagnostic Radiology; University of Texas MD Anderson Cancer Center; Houston Texas USA
| |
Collapse
|
7
|
Khorram FS, Faeghi F, Jafarisepehr A, Farshidfar Z. Evaluation of Respiratory Triggered Diffusion-Weighted MRI with Three b-Values Compared to ADC Map and Fast Spin Echo Heavily T2W in Differential Diagnosis of Hemangioma from Malignant Liver Lesions. J Med Imaging Radiat Sci 2018; 49:251-256. [DOI: 10.1016/j.jmir.2018.04.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 02/22/2018] [Accepted: 04/11/2018] [Indexed: 10/14/2022]
|
8
|
The role of apparent diffusion coefficient values in characterization of solid focal liver lesions: a prospective and comparative clinical study. SCIENCE CHINA-LIFE SCIENCES 2017; 60:16-22. [PMID: 28078512 DOI: 10.1007/s11427-016-0387-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Accepted: 11/09/2016] [Indexed: 12/14/2022]
Abstract
We evaluated and compared the diagnostic accuracy (DA) of apparent diffusion coefficient (ADC) values with that of lesion-to-liver ADC ratios in the characterization of solid focal liver lesions (FLLs). This prospective study was approved by the Institutional Human Ethics Board, after waiving written informed consent. Diffusion-weighted imaging and other routine magnetic resonance imaging were performed on 142 consecutive patients with suspected liver disease. The mean ADC values and lesion-to-liver ADC ratios were compared between benign and malignant solid FLLs. Receiver operating characteristic analysis was performed. The study participants included 46 patients (28 men, 18 women; mean age, 52.5 years) with 57 solid FLLs (32 malignant and 25 benign FLLs). The mean ADC values and ADC ratios of benign solid FLLs were significantly higher than those of malignant lesions (P<0.01). The difference between the area under the receiver operating characteristic curve of the ADC values (0.699) and ADC ratios (0.752) was not significant. Our study suggests that the DA of the ADC ratio is not significantly higher than that of ADC in characterizing solid FLLs.
Collapse
|
9
|
Boss A, Barth B, Filli L, Kenkel D, Wurnig MC, Piccirelli M, Reiner CS. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis. Eur J Radiol 2016; 85:1948-1955. [PMID: 27776645 DOI: 10.1016/j.ejrad.2016.09.002] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2016] [Revised: 09/02/2016] [Accepted: 09/05/2016] [Indexed: 01/02/2023]
Abstract
PURPOSE To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. MATERIALS AND METHODS Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). RESULTS In scheme (i) no differences in SNR were observed (p=0.321-0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. CONCLUSION SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.
Collapse
Affiliation(s)
- Andreas Boss
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
| | - Borna Barth
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland
| | - Lukas Filli
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland
| | - David Kenkel
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland
| | - Moritz C Wurnig
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland
| | - Marco Piccirelli
- Institute of Neuroradiology, University Hospital of Zurich, Switzerland
| | - Caecilia S Reiner
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland
| |
Collapse
|
10
|
Nakamura Y, Higaki T, Akiyama Y, Fukumoto W, Kajiwara K, Kaichi Y, Honda Y, Komoto D, Tatsugami F, Iida M, Ohmoto T, Date S, Awai K. Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging. Eur J Radiol Open 2016; 3:138-44. [PMID: 27489867 PMCID: PMC4959945 DOI: 10.1016/j.ejro.2016.07.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 06/30/2016] [Accepted: 07/02/2016] [Indexed: 12/16/2022] Open
Abstract
Purpose To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. Materials and methods In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm2) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm2, TE 70 ms; b-value 0 and 600 s/mm2, TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm2 at 1.5T and 3T as “o-1.5T-1000” and “o-3T-1000”. c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm2. c-DWI with b = 1000 and 1500 s/mm2 were defined as “c-1000” and “c-1500”. Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm2 on 1.5T- and 3T DWIs. Results Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Conclusions Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs.
Collapse
Key Words
- ADC, apparent diffusion coefficient
- CR, contrast ratio
- Computed diffusion-weighted imaging
- DWI, diffusion-weighted imaging
- Diffusion-weighted imaging
- Field strength
- HCC, hepatocellular carcinoma
- MRI, magnetic resonance imaging
- Non-complicated hepatic cysts
- SI, signal intensity
- SNR, signal-to-noise ratio
- T1-WI, T1-weighted MRI
- T2 shine-through effect
- T2-WI, T2-weighted MRI
- c-DWI, computed diffusion-weighted imaging
Collapse
Affiliation(s)
- Yuko Nakamura
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Toru Higaki
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Yuji Akiyama
- Department of Radiology, Hiroshima University Hospital, Hiroshima, Japan
| | - Wataru Fukumoto
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Kenji Kajiwara
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Yoko Kaichi
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Yukiko Honda
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Daisuke Komoto
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | | | - Makoto Iida
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | | | - Shuji Date
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| | - Kazuo Awai
- Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
11
|
Dohan A, Taylor S, Hoeffel C, Barret M, Allez M, Dautry R, Zappa M, Savoye-Collet C, Dray X, Boudiaf M, Reinhold C, Soyer P. Diffusion-weighted MRI in Crohn's disease: Current status and recommendations. J Magn Reson Imaging 2016; 44:1381-1396. [PMID: 27249184 DOI: 10.1002/jmri.25325] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Accepted: 05/12/2016] [Indexed: 12/19/2022] Open
Abstract
Over the past years, technological improvements and refinements in magnetic resonance imaging (MRI) hardware have made high-quality diffusion-weighted imaging (DWI) routinely possible for the bowel. DWI is promising for the detection and characterization of lesions in Crohn's disease (CD) and has been advocated as an alternative to intravenous gadolinium-based contrast agents. Furthermore, quantification using the apparent diffusion coefficient may have value as a biomarker of CD activity and has shown promise. In this article we critically review the literature pertaining to the value of DWI in CD for detection, characterization, and quantification of disease activity and complications. Although the body of supportive evidence is growing, it is clear that well-designed, multicenter studies are required before the role of DWI in clinical practice can be fully established. J. Magn. Reson. Imaging 2016;44:1381-1396.
Collapse
Affiliation(s)
- Anthony Dohan
- McGill University Health Center, Department of Radiology, McGill University Health Center, Montreal, QC, Canada
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- INSERM UMR 965, Paris, France
| | - Stuart Taylor
- Centre for Medical Imaging, University College London, Podium Level 2, University College Hospital, London, UK
| | | | - Maximilien Barret
- Department of Gastroenterology, Hôpital Cochin, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Matthieu Allez
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- Department of Gastroenterology, Hôpital Saint-Louis, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Raphael Dautry
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Magaly Zappa
- Department of Radiology, Hôpital Beaujon, Assistance Publique-Hôpitaux de Paris, Clichy, France
| | | | - Xavier Dray
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- Department of Gastroenterology, Hôpital Saint-Antoine, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Mourad Boudiaf
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - Caroline Reinhold
- McGill University Health Center, Department of Radiology, McGill University Health Center, Montreal, QC, Canada
| | - Philippe Soyer
- Department of Body and Interventional Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France
- Université Paris-Diderot, Sorbonne Paris Cité, Paris, France
- INSERM UMR 965, Paris, France
| |
Collapse
|
12
|
Diffusion-Weighted Imaging with Two Different b-Values in Detection of Solid Focal Liver Lesions. BIOMED RESEARCH INTERNATIONAL 2016; 2016:8128207. [PMID: 27019851 PMCID: PMC4785245 DOI: 10.1155/2016/8128207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/19/2015] [Accepted: 11/29/2015] [Indexed: 01/14/2023]
Abstract
One hundred and eighty-two consecutive patients with suspected liver disease were recruited to receive diffusion-weighted imaging (DWI) with two different b-values, in comparison with T2-weighted imaging (T2WI). The detection rate of three MR sequences in solid focal liver lesions (FLLs) and subgroup analyses were performed. Our prospective study found that DWI600 was equivalent to DWI100 and T2WI for the detection of solid FLLs overall but was significantly more accurate in the detection of malignant solid FLLs and lesions larger than 10 mm.
Collapse
|
13
|
Wang M, Li X, Zou J, Chen X, Chen S, Xiang W. Evaluation of Hepatic Tumors Using Intravoxel Incoherent Motion Diffusion-Weighted MRI. Med Sci Monit 2016; 22:702-9. [PMID: 26931063 PMCID: PMC4778409 DOI: 10.12659/msm.895909] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Background This study aimed to evaluate the diagnostic value of the D value, D* value, and f magnitude for identifying benign and malignant hepatic tumors using intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI). Material/Methods Data of 89 cases (123 lesions) with hepatic tumor confirmed by surgical pathology and postoperative follow-up were retrospectively collected. Among these cases, 40 cases were benign hepatic tumors (57 lesions) and 49 cases were malignant hepatic tumors (66 lesions). All subjects underwent conventional MRI with T1WI, T2WI, multi-b-value DWI, and dynamic enhanced LAVA scan. Diffusion-weighted images with 11 b values (0, 10, 20, 30, 50, 80, 100, 200, 400, 800, and 1000 s/mm2) were obtained to calculate true molecular diffusion (D), perfusion-related diffusion coefficient (D*), and perfusion fraction (f). The diagnostic performance in differentiating between malignant and benign hepatic lesions was analyzed. Results Malignant lesions had a significantly lower D value ([1.04±0.34]×10−3 mm2/s) and D* value ([16.5±7.7]×10−3 mm2/s) compared to benign lesions (D value: [1.70±0.55]×10−3 mm2/s, P<0.01; D* value: [21.7±9.9]×10−3 mm2/s, P<0.01). There was no statistically significant difference in f values between malignant (23.3±9.5) and benign lesions (33.5±14.9, P=0.13). In addition, D exhibited a better diagnostic performance than D* in terms of the area under the curve, sensitivity, and specificity when identifying malignancies from benign lesions. Conclusions D and D* are significant parameters for diagnosing hepatic tumors. Moreover, the D value is a more reliable parameter in distinguishing benign and malignant hepatic tumors.
Collapse
Affiliation(s)
- Mingjie Wang
- Department of Radiology, Lishui People's Hospital, Lishui, Zhejiang, China (mainland)
| | - Xudan Li
- Department of Radiology, Lishui People's Hospital, Lishui, Zhejiang, China (mainland)
| | - Jianxun Zou
- Department of Radiology, Lishui People's Hospital, Lishui, Zhejiang, China (mainland)
| | - Xugao Chen
- Department of Radiology, Lishui People's Hospital, Lishui, Zhejiang, China (mainland)
| | - Shuyan Chen
- Department of Radiology, Lishui People's Hospital, Lishui, Zhejiang, China (mainland)
| | - Wanqing Xiang
- Department of Radiology, Lishui People's Hospital, Lishui, Zhejiang, China (mainland)
| |
Collapse
|
14
|
Wang A, Shanbhogue AK, Dunst D, Hajdu CH, Rosenkrantz AB. Utility of diffusion-weighted MRI for differentiating acute from chronic cholecystitis. J Magn Reson Imaging 2015; 44:89-97. [PMID: 26691912 DOI: 10.1002/jmri.25128] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Accepted: 12/01/2015] [Indexed: 12/17/2022] Open
Abstract
PURPOSE To assess the use of diffusion-weighted imaging (DWI) for differentiating acute from chronic cholecystitis, in comparison with conventional magnetic resonance imaging (MRI) features. MATERIALS AND METHODS Liver MRI including DWI (b-values 0/500/1000s/mm(2) ) was performed at 1.5T ≤30 days before cholecystectomy in 83 patients with abdominal pain. Two radiologists assessed cases for conventional (gallstones, wall thickening, pericholecystic fluid, pericholecystic fat changes, gallbladder distension, pericholecystic liver enhancement, mural T2 -hyperintensity, mural hyperenhancement, mural striations, abscess, intraluminal membranes, and mural defect) and DWI (increased mural signal on high b-value images, visually low apparent diffusion coefficient [ADC], and ADC values) features. RESULTS Acute cholecystitis was present in 43%; chronic cholecystitis was present in 57%. Nine of 12 conventional features were more frequent in acute cholecystitis for both readers (P ≤ 0.003). Increased mural signal on high b-value images was more frequent (P < 0.001) in acute than chronic cholecystitis for R1 (92% vs. 32%) and R2 (83% vs. 30%). Sensitivity and specificity of increased signal on high b-value images were: R1, 92%/68%; R2, 83%/70%. Visually low ADC was more frequent in acute cholecystitis for R2 (P < 0.001) but not R1 (P = 0.406); ADC values were not different between groups for either reader (P = 0.104-0.139). Among conventional and DWI features, only increased signal on high b-value DWI was independently associated with acute cholecystitis for both readers (P = 0.006-0.012). CONCLUSION Visually increased mural signal on high b-value DWI was highly sensitive and moderately specific for acute cholecystitis, being an independent predictor relative to conventional features for both readers. Although requiring larger studies, DWI (particularly the high b-value images) may have additive value relative to conventional MRI-suspected acute cholecystitis. J. Magn. Reson. Imaging 2016;44:89-97.
Collapse
Affiliation(s)
- Annie Wang
- Department of Radiology, NYU School of Medicine, NYU Langone Medical Center, New York, New York, USA
| | - Alampady K Shanbhogue
- Department of Radiology, NYU School of Medicine, NYU Langone Medical Center, New York, New York, USA
| | - Diane Dunst
- Department of Radiology, NYU School of Medicine, NYU Langone Medical Center, New York, New York, USA
| | - Cristina H Hajdu
- Department of Pathology, NYU School of Medicine, NYU Langone Medical Center, New York, New York, USA
| | - Andrew B Rosenkrantz
- Department of Radiology, NYU School of Medicine, NYU Langone Medical Center, New York, New York, USA
| |
Collapse
|