1
|
Ohno Y, Fujisawa Y, Yoshikawa T, Seki S, Takenaka D, Fujii K, Ito Y, Kimata H, Akino N, Nagata H, Nomura M, Ueda T, Ozawa Y. Dynamic perfusion area-detector CT in non-small cell lung cancer with progressive fibrosing interstitial lung disease. Eur Radiol 2025:10.1007/s00330-025-11653-7. [PMID: 40402289 DOI: 10.1007/s00330-025-11653-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 03/24/2025] [Accepted: 04/09/2025] [Indexed: 05/23/2025]
Abstract
OBJECTIVES To determine the capability of dynamic contrast-enhanced (CE-) perfusion area-detector CT (ADCT) for detecting pathological structural changes in stage I non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS Sixty-three consecutive stage I NSCLC patients with progressive fibrosing interstitial lung disease (PF-ILD) underwent dynamic CE-perfusion ADCT analyzed by dual-input maximum slope (DMS) methods for total, pulmonary arterial and systemic arterial perfusion (TPDMS, PAPDMS and SAPDMS) maps, surgical treatment and pathological examination. Multicentric ROIs were then placed over sites assessed as normal lung, pulmonary emphysema, GGO or reticular pattern without traction bronchiectasis, reticular pattern with traction bronchiectasis and honeycombing in the resected lung. Next, an analysis of variance (ANOVA) followed by Tukey's honest significant difference (HSD) multiple comparison test was performed for a comparison of each of the perfusion parameters for five groups. Finally, discrimination accuracy for evaluation of lung parenchymal change was compared for all indexes and combined methods. RESULTS PAPDMSs of abnormal lungs were significantly lower than that of normal lungs (p < 0.0001). SAPDMSs of normal or emphysematous lungs were significantly lower than those of others (p < 0.0001). SAPDMS of GGO or reticular pattern without traction bronchiectasis was significantly lower than that for reticular pattern with traction bronchiectasis and honeycombing (p < 0.0001). Discrimination accuracy of combined perfusion index was significantly higher than that of each index (p < 0.0001). CONCLUSION Dynamic CE-perfusion ADCT is useful for detecting pathological structural changes in stage I NSCLC patients with PF-ILD. KEY POINTS Question Can dynamic first-pass contrast-enhanced perfusion matrices evaluate parenchymal lung changes and disease severity of parenchymal diseases in stage I non-small cell lung cancer (NSCLC) patients? Findings Perfusion indexes differentiated significantly among normal lung, emphysema, GGO or reticular pattern without traction bronchiectasis, reticular pattern with traction bronchiectasis and honeycombing and significantly improved discrimination accuracy by combined methods. Clinical relevance Dynamic first-pass contrast-enhanced perfusion area-detector CT has the potential to assess underlying pathologies and pulmonary functional changes in stage I non-small cell carcinoma patients with progressive fibrosing interstitial lung disease.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan.
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Mediciine, Toyoake, Japan.
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
| | | | - Takeshi Yoshikawa
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
- Division of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan
| | - Shinichiro Seki
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
- Division of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan
| | - Daisuke Takenaka
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Kenji Fujii
- Canon Medical Systems Corporation, Otawara, Japan
| | - Yuya Ito
- Canon Medical Systems Corporation, Otawara, Japan
| | | | | | - Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Mediciine, Toyoake, Japan
| | - Masahiko Nomura
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Takahiro Ueda
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Yoshiyuki Ozawa
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| |
Collapse
|
2
|
Sebek J, Taeprasartsit P, Pathomparai C, Dupuy DE, Wibowo H, Prakash P. Computational modeling of microwave ablation of lung tumors: Assessment of model-predictions against post-treatment imaging. Med Phys 2025. [PMID: 40405374 DOI: 10.1002/mp.17897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Revised: 04/18/2025] [Accepted: 05/07/2025] [Indexed: 05/24/2025] Open
Abstract
BACKGROUND Percutaneous microwave ablation is a clinically established method for treatment of unresectable lung nodules. When planning the intervention, the size of ablation zone, which should encompass the nodule as well as a surrounding margin of normal tissue, is predicted via manufacturer-provided geometric models, which do not consider patient-specific characteristics. However, the size and shape of ablation is dependent on tissue composition and properties and can vary between patients. PURPOSE To comparatively assess performance of a computational model-based approach and manufacturer geometric model for predicting extent of ablation zones following microwave lung ablation procedures on a retrospectively collected clinical imaging dataset. METHODS A retrospective computed-tomography (CT) imaging dataset was assembled of 50 patients treated with microwave ablation of lung tumors at a single institution. For each case, the dataset consisted of a pre-procedure CT acquired without the ablation applicator, a peri-procedure CT scan with the ablation applicator in position, and post-procedure CT scan to assess the ablation zone extent acquired on the first follow-up visit. A physics-based computational model of microwave absorption and bioheat transfer was implemented using the finite element method, with the model geometry incorporating key tissue types within 2 cm of the applicator as informed by imaging data. The model-predicted extent of the ablation zone was estimated using the Arrhenius thermal damage model. The ablation zone predicted by the manufacturer geometric model consisted of an ellipsoid registered with the applicator position and dimensions provided by instructions for use documentation. Both ablation estimates were compared to ground truth ablation zone segmented from post-procedure CT via Dice similarity coefficient (DSC) and average absolute error (AAE). The statistically significant difference at level 0.05 in performance between both ablation prediction methods was tested with permutation test on DSC as well as AAE datasets with applied Bonferroni multiple-comparison correction. RESULTS Receiver operating characteristic analysis of the predictive power of the volume of insufficient coverage (i.e. tumor volume which did not receive an ablative thermal dose) as an indicator of local tumor recurrence yielded an area under the curve of 0.84, illustrating the clinical significance of accurate prediction of ablation zone extents. Across all cases, AAEs were 3.65 ± 1.12 mm, and 5.11 ± 1.93 mm for patient-specific computational and manufacturer geometric models respectively. Similarly, average DSCs were 0.55 ± 0.14, and 0.46 ± 0.19 for computational and manufacturer geometric models respectively. The manufacturer geometric model overpredicted volume of the ablation zone compared to ground truth by 141% on average, whereas the patient-specific computational model overpredicted ablation zone volumes by 31.5% on average. CONCLUSIONS Patient-specific physics-based computational models of lung microwave ablation yield improved prediction of microwave ablation extent compared to the manufacturer geometric model.
Collapse
Affiliation(s)
- Jan Sebek
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas, USA
- Department of Circuit Theory, Czech Technical University in Prague, Praha, CZ
| | | | | | - Damian E Dupuy
- Department of Diagnostic Imaging, Rhode Island Hospital, The Warren Alpert Medical School of Brown University, Providence, Rhode Island, USA
- Department of Radiology, Cape Cod Hospital, Hyannis, Massachusetts, USA
| | | | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas, USA
- Department of Biomedical Engineering, The George Washington University, Washington, D.C., USA
| |
Collapse
|
3
|
Ohno Y, Ozawa Y, Nagata H, Bando S, Cong S, Takahashi T, Oshima Y, Hamabuchi N, Matsuyama T, Ueda T, Yoshikawa T, Takenaka D, Toyama H. Area-Detector Computed Tomography for Pulmonary Functional Imaging. Diagnostics (Basel) 2023; 13:2518. [PMID: 37568881 PMCID: PMC10416899 DOI: 10.3390/diagnostics13152518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/22/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
An area-detector CT (ADCT) has a 320-detector row and can obtain isotropic volume data without helical scanning within an area of nearly 160 mm. The actual-perfusion CT data within this area can, thus, be obtained by means of continuous dynamic scanning for the qualitative or quantitative evaluation of regional perfusion within nodules, lymph nodes, or tumors. Moreover, this system can obtain CT data with not only helical but also step-and-shoot or wide-volume scanning for body CT imaging. ADCT also has the potential to use dual-energy CT and subtraction CT to enable contrast-enhanced visualization by means of not only iodine but also xenon or krypton for functional evaluations. Therefore, systems using ADCT may be able to function as a pulmonary functional imaging tool. This review is intended to help the reader understand, with study results published during the last a few decades, the basic or clinical evidence about (1) newly applied reconstruction methods for radiation dose reduction for functional ADCT, (2) morphology-based pulmonary functional imaging, (3) pulmonary perfusion evaluation, (4) ventilation assessment, and (5) biomechanical evaluation.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan;
| | - Yoshiyuki Ozawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan;
| | - Shuji Bando
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Shang Cong
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Tomoki Takahashi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Yuka Oshima
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Nayu Hamabuchi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takahiro Matsuyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takeshi Yoshikawa
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi 673-0021, Hyogo, Japan
| | - Daisuke Takenaka
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi 673-0021, Hyogo, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| |
Collapse
|
4
|
Ohno Y, Yui M, Yamamoto K, Takenaka D, Koyama H, Nagata H, Ueda T, Ikeda H, Ozawa Y, Toyama H, Yoshikawa T. Chemical Exchange Saturation Transfer MRI: Capability for Predicting Therapeutic Effect of Chemoradiotherapy on Non-Small Cell Lung Cancer Patients. J Magn Reson Imaging 2023; 58:174-186. [PMID: 36971493 DOI: 10.1002/jmri.28691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 03/29/2023] Open
Abstract
BACKGROUND Amide proton transfer (APT) weighted chemical exchange saturation transfer CEST (APTw/CEST) magnetic resonance imaging (MRI) has been suggested as having the potential for assessing the therapeutic effect of brain tumors or rectal cancer. Moreover, diffusion-weighted imaging (DWI) and positron emission tomography fused with computed tomography by means of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG-PET/CT) have been suggested as useful in same setting. PURPOSE To compare the capability of APTw/CEST imaging, DWI, and FDG-PET/CT for predicting therapeutic effect of chemoradiotherapy (CRT) on stage III non-small cell lung cancer (NSCLC) patients. STUDY TYPE Prospective. POPULATION Eighty-four consecutive patients with Stage III NSCLC, 45 men (age range, 62-75 years; mean age, 71 years) and 39 women (age range, 57-75 years; mean age, 70 years). All patients were then divided into two groups (Response Evaluation Criteria in Solid Tumors [RECIST] responders, consisting of the complete response and partial response groups, and RECIST non-responders, consisting of the stable disease and progressive disease groups). FIELD STRENGTH/SEQUENCE 3 T, echo planar imaging or fast advanced spin-echo (FASE) sequences for DWI and 2D half Fourier FASE sequences with magnetization transfer pulses for CEST imaging. ASSESSMENT Magnetization transfer ratio asymmetry (MTRasym ) at 3.5 ppm, apparent diffusion coefficient (ADC), and maximum standard uptake value (SUVmax, ) on PET/CT were assessed by means of region of interest (ROI) measurements at primary tumor. STATISTICAL TESTS Kaplan-Meier method followed by log-rank test and Cox proportional hazards regression analysis with multivariate analysis. A P value <0.05 was considered statistically significant. RESULTS Progression-free survival (PFS) and overall survival (OS) had significant difference between two groups. MTRasym at 3.5 ppm (hazard ratio [HR] = 0.70) and SUVmax (HR = 1.41) were identified as significant predictors for PFS. Tumor staging (HR = 0.57) was also significant predictors for OS. DATA CONCLUSION APTw/CEST imaging showed potential performance as DWI and FDG-PET/CT for predicting the therapeutic effect of CRT on stage III NSCLC patients. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Masao Yui
- Canon Medical Systems Corporation, Otawara, Japan
| | | | - Daisuke Takenaka
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan
| | - Hisanobu Koyama
- Department of Radiology, Osaka Police Hospital, Osaka, Japan
- Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Japan
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Hirotaka Ikeda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Yoshiyuki Ozawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
| | - Takeshi Yoshikawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Japan
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Japan
| |
Collapse
|
5
|
Cheng Z, Wang Y, Yuan M, Liang J, Feng Y, Shi Y, Zhang Z, Shan F. CT perfusion imaging can detect residual lung tumor early after radiofrequency ablation: a preliminary animal study on both tumoral and peri-tumoral region assessment. J Thorac Dis 2022; 14:64-75. [PMID: 35242369 PMCID: PMC8828527 DOI: 10.21037/jtd-21-967] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 12/06/2021] [Indexed: 11/23/2022]
Abstract
BACKGROUND Radiofrequency ablation (RFA) is a minimally invasive procedure to treat lung cancer. Timely evaluation on residual lung tumor after RFA is crucial to the prognosis, hence, our objective is to assess CT perfusion (CTP) on detection of residual lung tumor early after RFA. METHODS CTP imaging was performed in 24 lung VX2 tumor models 1 day before and within 1 hour after RFA. CTP maps with dual-input (n=24) and single-input [n=13, with predominant ground glass opacity (GGO) after RFA] models were generated using the maximal slope method. Regions of interest were independently placed on the maximal cross-sectional tumor before and after RFA and on GGO after RFA by two thoracic radiologists. The bronchial flow (BF), pulmonary flow (PF) and perfusion index (PI) were compared between pre-RFA and post-RFA images. The parameters (BF, PF and PI of tumor; PF of GGO) of the complete and incomplete RFA groups were compared based on nicotinamide adenine dinucleotide hydrogen (NADH) and TdT-mediated dUTP nick-end labeling (TUNEL) staining and were correlated with the microvascular density (MVD). RESULTS The BF and PF decreased after RFA (all P values <0.03). The decrease in BF and PF (ΔBF and ΔPF) in the complete RFA group was higher (P=0.01; 0.02). The areas under the curve (AUC) of ΔBF and ΔPF at 14.85 and 17.25 mL/min/100 mL in determination of tumor with complete ablation were 0.80 and 0.78, respectively. ΔBF was positively correlated with MVD (P=0.046, r=0.468). PF of GGO with incomplete RFA was higher (P=0.001). The AUC of PF ≤29.4 mL/min/100 mL in determination of tumor with complete ablation was 0.99. CONCLUSIONS CTP could detect residual lung tumor early after RFA in a rabbit model, which might provide a clinical solution to early treatment assessment after RFA.
Collapse
Affiliation(s)
- Zenghui Cheng
- Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University, School of Medicine, Shanghai, China
| | - Yixue Wang
- Department of Critical Care Medicine, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Min Yuan
- Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Jianxiao Liang
- Department of Radiology, Dongying People’s Hospital, Dongying, China
| | - Yanling Feng
- Department of Pathology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Yuxin Shi
- Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Zhiyong Zhang
- Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Fei Shan
- Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| |
Collapse
|
6
|
Can dynamic imaging, using 18F-FDG PET/CT and CT perfusion differentiate between benign and malignant pulmonary nodules? Radiol Oncol 2021; 55:259-267. [PMID: 34051709 PMCID: PMC8366734 DOI: 10.2478/raon-2021-0024] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 04/24/2021] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND The aim of the study was to derive and compare metabolic parameters relating to benign and malignant pulmonary nodules using dynamic 2-deoxy-2-[fluorine-18]fluoro-D-glucose (18F-FDG) PET/CT, and nodule perfusion parameters derived through perfusion computed tomography (CT). PATIENTS AND METHODS Twenty patients with 21 pulmonary nodules incidentally detected on CT underwent a dynamic 18F-FDG PET/CT and a perfusion CT. The maximum standardized uptake value (SUVmax) was measured on conventional 18F-FDG PET/CT images. The influx constant (Ki ) was calculated from the dynamic 18F-FDG PET/CT data using Patlak model. Arterial flow (AF) using the maximum slope model and blood volume (BV) using the Patlak plot method for each nodule were calculated from the perfusion CT data. All nodules were characterized as malignant or benign based on histopathology or 2 year follow up CT. All parameters were statistically compared between the two groups using the nonparametric Mann-Whitney test. RESULTS Twelve malignant and 9 benign lung nodules were analysed (median size 20.1 mm, 9-29 mm) in 21 patients (male/female = 11/9; mean age ± SD: 65.3 ± 7.4; age range: 50-76 years). The average SUVmax values ± SD of the benign and malignant nodules were 2.2 ± 1.7 vs. 7.0 ± 4.5, respectively (p = 0.0148). Average Ki values in benign and malignant nodules were 0.0057 ± 0.0071 and 0.0230 ± 0.0155 min-1, respectively (p = 0.0311). Average BV for the benign and malignant nodules were 11.6857 ± 6.7347 and 28.3400 ± 15.9672 ml/100 ml, respectively (p = 0.0250). Average AF for the benign and malignant nodules were 74.4571 ± 89.0321 and 89.200 ± 49.8883 ml/100g/min, respectively (p = 0.1613). CONCLUSIONS Dynamic 18F-FDG PET/CT and perfusion CT derived blood volume had similar capability to differentiate benign from malignant lung nodules.
Collapse
|
7
|
Ohno Y, Seo JB, Parraga G, Lee KS, Gefter WB, Fain SB, Schiebler ML, Hatabu H. Pulmonary Functional Imaging: Part 1-State-of-the-Art Technical and Physiologic Underpinnings. Radiology 2021; 299:508-523. [PMID: 33825513 DOI: 10.1148/radiol.2021203711] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Over the past few decades, pulmonary imaging technologies have advanced from chest radiography and nuclear medicine methods to high-spatial-resolution or low-dose chest CT and MRI. It is currently possible to identify and measure pulmonary pathologic changes before these are obvious even to patients or depicted on conventional morphologic images. Here, key technological advances are described, including multiparametric CT image processing methods, inhaled hyperpolarized and fluorinated gas MRI, and four-dimensional free-breathing CT and MRI methods to measure regional ventilation, perfusion, gas exchange, and biomechanics. The basic anatomic and physiologic underpinnings of these pulmonary functional imaging techniques are explained. In addition, advances in image analysis and computational and artificial intelligence (machine learning) methods pertinent to functional lung imaging are discussed. The clinical applications of pulmonary functional imaging, including both the opportunities and challenges for clinical translation and deployment, will be discussed in part 2 of this review. Given the technical advances in these sophisticated imaging methods and the wealth of information they can provide, it is anticipated that pulmonary functional imaging will be increasingly used in the care of patients with lung disease. © RSNA, 2021 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Joon Beom Seo
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Grace Parraga
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Kyung Soo Lee
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Warren B Gefter
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Sean B Fain
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Mark L Schiebler
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| | - Hiroto Hatabu
- From the Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan (Y.O.); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan (Y.O.); Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.S.); Department of Medicine, Robarts Research Institute, and Department of Medical Biophysics, Western University, London, Canada (G.P.); Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (SKKU-SOM), Seoul, Korea (K.S.L.); Department of Radiology, Penn Medicine, University of Pennsylvania, Philadelphia, Pa (W.B.G.); Departments of Medical Physics and Radiology (S.B.F., M.L.S.), UW-Madison School of Medicine and Public Health, Madison, Wis; and Center for Pulmonary Functional Imaging, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02215 (H.H.)
| |
Collapse
|
8
|
Taiji R, Nishiofuku H, Tanaka T, Minamiguchi K, Fukuoka Y, Saito N, Taguchi H, Matsumoto T, Marugami N, Hirai T, Kichikawa K. Useful Parameters in Dynamic Contrast-enhanced Ultrasonography for Identifying Early Response to Chemotherapy in a Rat Liver Tumor Model. J Clin Imaging Sci 2021; 11:15. [PMID: 33767907 PMCID: PMC7981939 DOI: 10.25259/jcis_6_2020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 02/15/2021] [Indexed: 12/24/2022] Open
Abstract
Objectives The objective of the study is to determine a parameter on the time-intensity curve (TIC) of dynamic contrast-enhanced ultrasonography (DCE-US) that best correlates with tumor growth and to evaluate whether the parameter could correlate with the early response to irinotecan in a rat liver tumor model. Material and Methods Twenty rats with tumors were evaluated (control: Saline, n = 6; treatment: Irinotecan, n = 14) regarding four parameters from TIC: Peak intensity (PI), k value, slope (PI × k), and time to peak (TTP). Relative changes in maximum tumor diameter between day 0 and 10, and parameters in the first 3 days were evaluated. The Mann-Whitney U-test was used to compare differences in tumor size and other parameters. Pearson's correlation coefficients (r) between tumor size and parameters in the control group were calculated. In the treatment group, relative changes of parameters in the first 3 days were compared between responder and non-responder (<20% and ≥20% increase in size on day 10, respectively). Results PI, k value, PI × k, and TTP significantly correlated with tumor growth (r = 0.513, 0.911, 0.665, and 0.741, respectively). The mean RC in k value among responders (n = 6) was significantly lower than non-responders (n = 8) (mean k value, 4.96 vs. 72.5; P = 0.003). Conclusion Parameters of DCE-US could be a useful parameter for identifying early response to irinotecan.
Collapse
Affiliation(s)
- Ryosuke Taiji
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | | | - Toshihiro Tanaka
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | | | - Yasushi Fukuoka
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Natsuhiko Saito
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Hidehiko Taguchi
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Takeshi Matsumoto
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Nagaaki Marugami
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Toshiko Hirai
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Kimihiko Kichikawa
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| |
Collapse
|
9
|
Besson FL, Fernandez B, Faure S, Mercier O, Seferian A, Mignard X, Mussot S, le Pechoux C, Caramella C, Botticella A, Levy A, Parent F, Bulifon S, Montani D, Mitilian D, Fadel E, Planchard D, Besse B, Ghigna-Bellinzoni MR, Comtat C, Lebon V, Durand E. 18F-FDG PET and DCE kinetic modeling and their correlations in primary NSCLC: first voxel-wise correlative analysis of human simultaneous [18F]FDG PET-MRI data. EJNMMI Res 2020; 10:88. [PMID: 32734484 PMCID: PMC7392998 DOI: 10.1186/s13550-020-00671-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 07/14/2020] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVES To decipher the correlations between PET and DCE kinetic parameters in non-small-cell lung cancer (NSCLC), by using voxel-wise analysis of dynamic simultaneous [18F]FDG PET-MRI. MATERIAL AND METHODS Fourteen treatment-naïve patients with biopsy-proven NSCLC prospectively underwent a 1-h dynamic [18F]FDG thoracic PET-MRI scan including DCE. The PET and DCE data were normalized to their corresponding T1-weighted MR morphological space, and tumors were masked semi-automatically. Voxel-wise parametric maps of PET and DCE kinetic parameters were computed by fitting the dynamic PET and DCE tumor data to the Sokoloff and Extended Tofts models respectively, by using in-house developed procedures. Curve-fitting errors were assessed by computing the relative root mean square error (rRMSE) of the estimated PET and DCE signals at the voxel level. For each tumor, Spearman correlation coefficients (rs) between all the pairs of PET and DCE kinetic parameters were estimated on a voxel-wise basis, along with their respective bootstrapped 95% confidence intervals (n = 1000 iterations). RESULTS Curve-fitting metrics provided fit errors under 20% for almost 90% of the PET voxels (median rRMSE = 10.3, interquartile ranges IQR = 8.1; 14.3), whereas 73.3% of the DCE voxels showed fit errors under 45% (median rRMSE = 31.8%, IQR = 22.4; 46.6). The PET-PET, DCE-DCE, and PET-DCE voxel-wise correlations varied according to individual tumor behaviors. Beyond this wide variability, the PET-PET and DCE-DCE correlations were mainly high (absolute rs values > 0.7), whereas the PET-DCE correlations were mainly low to moderate (absolute rs values < 0.7). Half the tumors showed a hypometabolism with low perfused/vascularized profile, a hallmark of hypoxia, and tumor aggressiveness. CONCLUSION A dynamic "one-stop shop" procedure applied to NSCLC is technically feasible in clinical practice. PET and DCE kinetic parameters assessed simultaneously are not highly correlated in NSCLC, and these correlations showed a wide variability among tumors and patients. These results tend to suggest that PET and DCE kinetic parameters might provide complementary information. In the future, this might make PET-MRI a unique tool to characterize the individual tumor biological behavior in NSCLC.
Collapse
Affiliation(s)
- Florent L Besson
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMAPs, 91401, Orsay, France.
- Department of Biophysics and Nuclear Medicine-Molecular Imaging, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, CHU Bicêtre, 94270, Le Kremlin-Bicêtre, France.
- School of Medicine, Université Paris-Saclay, Le Kremlin-Bicêtre, France.
| | | | - Sylvain Faure
- Laboratoire de Mathématiques d'Orsay, CNRS, Université Paris-Saclay, 91405, Orsay, France
| | - Olaf Mercier
- Department of Thoracic and Vascular Surgery and Heart-Lung Transplantation, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - Andrei Seferian
- Service de Pneumologie, Centre de Référence de l'Hypertension Pulmonaire, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, 94270, Le Kremlin-Bicêtre, France
- Inserm UMR_S999, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - Xavier Mignard
- Service de Pneumologie, Centre de Référence de l'Hypertension Pulmonaire, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, 94270, Le Kremlin-Bicêtre, France
| | - Sacha Mussot
- Department of Thoracic and Vascular Surgery and Heart-Lung Transplantation, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - Cecile le Pechoux
- Department of Radiation Oncology, Institut d'Oncologie Thoracique (IOT), Gustave Roussy, Université Paris Saclay, Villejuif, France
| | - Caroline Caramella
- Department of Radiology, Institut d'Oncologie Thoracique (IOT), Gustave Roussy, Université Paris Saclay, Villejuif, France
| | - Angela Botticella
- Department of Radiation Oncology, Institut d'Oncologie Thoracique (IOT), Gustave Roussy, Université Paris Saclay, Villejuif, France
| | - Antonin Levy
- Department of Radiation Oncology, Institut d'Oncologie Thoracique (IOT), Gustave Roussy, Université Paris Saclay, Villejuif, France
| | - Florence Parent
- Service de Pneumologie, Centre de Référence de l'Hypertension Pulmonaire, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, 94270, Le Kremlin-Bicêtre, France
- Inserm UMR_S999, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - Sophie Bulifon
- Service de Pneumologie, Centre de Référence de l'Hypertension Pulmonaire, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, 94270, Le Kremlin-Bicêtre, France
- Inserm UMR_S999, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - David Montani
- Service de Pneumologie, Centre de Référence de l'Hypertension Pulmonaire, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, 94270, Le Kremlin-Bicêtre, France
- Inserm UMR_S999, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - Delphine Mitilian
- Department of Thoracic and Vascular Surgery and Heart-Lung Transplantation, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - Elie Fadel
- Department of Thoracic and Vascular Surgery and Heart-Lung Transplantation, Marie Lannelongue Hospital, 92350, Le Plessis Robinson, France
| | - David Planchard
- Department of Oncology, Institut d'Oncologie Thoracique (IOT), Gustave Roussy, Université Paris Saclay, Villejuif, France
| | - Benjamin Besse
- Department of Oncology, Institut d'Oncologie Thoracique (IOT), Gustave Roussy, Université Paris Saclay, Villejuif, France
| | | | - Claude Comtat
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMAPs, 91401, Orsay, France
- School of Medicine, Université Paris-Saclay, Le Kremlin-Bicêtre, France
| | - Vincent Lebon
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMAPs, 91401, Orsay, France
- School of Medicine, Université Paris-Saclay, Le Kremlin-Bicêtre, France
| | - Emmanuel Durand
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMAPs, 91401, Orsay, France
- Department of Biophysics and Nuclear Medicine-Molecular Imaging, Hôpitaux Universitaires Paris-Saclay, Assistance Publique-Hôpitaux de Paris, CHU Bicêtre, 94270, Le Kremlin-Bicêtre, France
- School of Medicine, Université Paris-Saclay, Le Kremlin-Bicêtre, France
| |
Collapse
|
10
|
Wu Q, Zhong L, Xie X. The value of four imaging modalities to distinguish malignant from benign solitary pulmonary nodules: a study based on 73 cohorts incorporating 7956 individuals. Clin Transl Oncol 2020; 23:296-310. [PMID: 32548796 DOI: 10.1007/s12094-020-02418-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 06/02/2020] [Indexed: 12/19/2022]
Abstract
BACKGROUND Solitary pulmonary nodules (SPNs) frequently bother oncologists. The differentiation of malignant from benign nodules with non-invasive approach remains a tough challenge. This study was designed to assess the diagnostic accuracy of dynamic computed tomography (CT), dynamic magnetic resonance imaging (MRI), fluorine 18 fluorodeoxyglucose (18F-FDG) positron emission tomography (PET), and technetium 99 m (99mTc) depreotide single photon emission computed tomography (SPECT) for SPNs. METHODS Electronic databases of MEDLINE, PubMed, EMBASE, and Cochrane Library were searched to identify relevant trials. The primary evaluation index of diagnostic accuracy was areas under the summary receiver-operating characteristic (SROC) curve. The results were analyzed utilizing Stata 12.0 statistical software. RESULTS Seventy-three trials incorporating 7956 individuals were recruited. Sensitivities, specificities, positive likelihood ratios, negative likelihood ratios, diagnostic score, diagnostic odds ratios, and areas under the SROC curve with 95% confidence intervals were, respectively, 0.92 (0.89-0.95), 0.64 (0.54-0.74), 2.60 (1.98-3.42), 0.12 (0.08-0.17), 3.10 (2.62-3.59), 22.24 (13.67-36.17), and 0.91 (0.88-0.93) for CT; 0.92 (0.86-0.95), 0.85 (0.77-0.90), 6.01 (3.90-9.24), 0.10 (0.06-0.17), 4.12 (3.41-4.82), 61.39 (30.41-123.93), and 0.94 (0.92-0.96) for MRI; 0.90 (0.86-0.93), 0.73 (0.65-0.79), 3.28 (2.56-4.20), 0.14 (0.10-0.19), 3.16 (2.69-3.64), 23.68 (14.74-38.05), and 0.90 (0.87-0.92) for 18F-FDG PET; and 0.93 (0.88-0.96), 0.70 (0.56-0.81), 3.12 (2.03-4.81), 0.10 (0.06-0.17), 3.43 (2.63-4.22), 30.74 (13.84-68.27), and 0.93 (0.91-0.95) for 99mTc-depreotide SPECT. CONCLUSION The dynamic MRI, dynamic CT, 18F-FDG PET, and 99mTc-depreotide SPECT were favorable non-invasive approaches to distinguish malignant SPNs from benign. Moreover, from the viewpoint of cost-effectiveness and avoiding radiation, the dynamic MRI was recommendable for SPNs.
Collapse
Affiliation(s)
- Q Wu
- Department of Oncology, The First Affiliated Hospital of Fujian Medical University, Chazhong Road No 20, Fuzhou, 350005, Fujian, China
| | - L Zhong
- Department of Oncology, The First Affiliated Hospital of Fujian Medical University, Chazhong Road No 20, Fuzhou, 350005, Fujian, China.,Department of Medical Oncology, The Second Hospital of Longyan, Fujian, 364000, China
| | - X Xie
- Department of Oncology, The First Affiliated Hospital of Fujian Medical University, Chazhong Road No 20, Fuzhou, 350005, Fujian, China.
| |
Collapse
|
11
|
Lee SH, Rimner A, Deasy JO, Hunt MA, Tyagi N. Dual-input tracer kinetic modeling of dynamic contrast-enhanced MRI in thoracic malignancies. J Appl Clin Med Phys 2019; 20:169-188. [PMID: 31602789 PMCID: PMC6839367 DOI: 10.1002/acm2.12740] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 09/09/2019] [Accepted: 09/11/2019] [Indexed: 12/29/2022] Open
Abstract
Pulmonary perfusion with dynamic contrast‐enhanced (DCE‐) MRI is typically assessed using a single‐input tracer kinetic model. Preliminary studies based on perfusion CT are indicating that dual‐input perfusion modeling of lung tumors may be clinically valuable as lung tumors have a dual blood supply from the pulmonary and aortic system. This study aimed to investigate the feasibility of fitting dual‐input tracer kinetic models to DCE‐MRI datasets of thoracic malignancies, including malignant pleural mesothelioma (MPM) and nonsmall cell lung cancer (NSCLC), by comparing them to single‐input (pulmonary or systemic arterial input) tracer kinetic models for the voxel‐level analysis within the tumor with respect to goodness‐of‐fit statistics. Fifteen patients (five MPM, ten NSCLC) underwent DCE‐MRI prior to radiotherapy. DCE‐MRI data were analyzed using five different single‐ or dual‐input tracer kinetic models: Tofts‐Kety (TK), extended TK (ETK), two compartment exchange (2CX), adiabatic approximation to the tissue homogeneity (AATH) and distributed parameter (DP) models. The pulmonary blood flow (BF), blood volume (BV), mean transit time (MTT), permeability‐surface area product (PS), fractional interstitial volume (vI), and volume transfer constant (KTrans) were calculated for both single‐ and dual‐input models. The pulmonary arterial flow fraction (γ), pulmonary arterial blood flow (BFPA) and systemic arterial blood flow (BFA) were additionally calculated for only dual‐input models. The competing models were ranked and their Akaike weights were calculated for each voxel according to corrected Akaike information criterion (cAIC). The optimal model was chosen based on the lowest cAIC value. In both types of tumors, all five dual‐input models yielded lower cAIC values than their corresponding single‐input models. The 2CX model was the best‐fitted model and most optimal in describing tracer kinetic behavior to assess microvascular properties in both MPM and NSCLC. The dual‐input 2CX‐model‐derived BFA was the most significant parameter in differentiating adenocarcinoma from squamous cell carcinoma histology for NSCLC patients.
Collapse
Affiliation(s)
- Sang Ho Lee
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Joseph O Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Margie A Hunt
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Neelam Tyagi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
12
|
Ohno Y, Fujisawa Y, Yui M, Takenaka D, Koyama H, Sugihara N, Yoshikawa T. Solitary pulmonary nodule: Comparison of quantitative capability for differentiation and management among dynamic CE-perfusion MRI at 3 T system, dynamic CE-perfusion ADCT and FDG-PET/CT. Eur J Radiol 2019; 115:22-30. [PMID: 31084755 DOI: 10.1016/j.ejrad.2019.03.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 02/20/2019] [Accepted: 03/24/2019] [Indexed: 12/17/2022]
Abstract
PURPOSE To prospectively compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion MR imaging with ultra-short TE and area-detector CT (ADCT), analyzed with the same mathematical methods, and that of FDG-PET/CT for diagnosis and management of solitary pulmonary nodules (SPNs). METHODS AND MATERIALS Our institutional review board approved this study and written informed consent was obtained from all subjects. A total 57 consecutive patients with 71 nodules prospectively underwent dynamic CE-perfusion ADCT and MR imaging with ultra-short TE, FDG-PET/CT, as well as microbacterial and/or pathological examinations. The nodules were classified into malignant nodules (n = 45) and benign nodules (n = 26). Pulmonary arterial, systemic arterial and total perfusions were determined by means of dual-input maximum slope models on ADCT and MR imaging and maximum values of standard uptake values (SUVmax) on PET/CT. Receiver operating characteristic (ROC) analysis was performed for each index, and sensitivity, specificity and accuracy were compared by McNemar's test. RESULTS Areas under the curve (Azs) of total perfusion on ADCT (Az = 0.89) and MR imaging (Az = 0.88) were significantly larger than those of systemic arterial perfusion and MR imaging (p<0.05). Accuracy of total perfusion on ADCT (87.3% [62/71]) and MR imaging (87.3% [62/71]) was significantly higher than that of systemic arterial perfusion for both methods (77.5% [55/71] p = 0.02) and SUVmax (78.9% [56/71], p = 0.03). CONCLUSION Dynamic CE-perfusion MR imaging with ultra-short TE and ADCT and have similar potential capabilities, and are superior to FDG-PET/CT in this setting.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan; Department of Radiology, Fujita Health University School of Medicine.
| | | | - Masao Yui
- Canon Medical Systems Corporation, Otawara, Japan
| | | | - Hisanobu Koyama
- Department of Radiology, Osaka Police Hospital, Osaka, Japan
| | | | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|
13
|
Seki S, Fujisawa Y, Yui M, Kishida Y, Koyama H, Ohyu S, Sugihara N, Yoshikawa T, Ohno Y. Dynamic Contrast-enhanced Area-detector CT vs Dynamic Contrast-enhanced Perfusion MRI vs FDG-PET/CT: Comparison of Utility for Quantitative Therapeutic Outcome Prediction for NSCLC Patients Undergoing Chemoradiotherapy. Magn Reson Med Sci 2019; 19:29-39. [PMID: 30880291 PMCID: PMC7067914 DOI: 10.2463/mrms.mp.2018-0158] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To directly compare the utility for therapeutic outcome prediction of dynamic first-pass contrast-enhanced (CE)-perfusion area-detector computed tomography (ADCT), MR imaging assessed with the same mathematical method and 2-[fluorine-18]-fluoro-2-deoxy-d-glucose-positron emission tomography combined with CT (PET/CT) for non-small cell lung cancer (NSCLC) patients treated with chemoradiotherapy. MATERIALS AND METHODS Forty-three consecutive stage IIIB NSCLC patients, consisting of 25 males (mean age ± standard deviation: 66.6 ± 8.7 years) and 18 females (66.4 ± 8.2 years) underwent PET/CT, dynamic CE-perfusion ADCT and MR imaging, chemoradiotherapy, and follow-up examination. In each patient, total, pulmonary arterial, and systemic arterial perfusions were calculated from both perfusion data and SUVmax on PET/CT, assessed for each targeted lesion, and averaged to determine final values. Receiver operating characteristics analyses were performed to compare the utility for distinguishing responders from non-responders using Response Evaluation Criteria in Solid Tumor (RECIST) 1.1 criteria. Overall survival (OS) assessed with each index were compared between two groups by means of the Kaplan-Meier method followed by the log-rank test. RESULTS Area under the curve (Az) for total perfusion on ADCT was significantly larger than that of pulmonary arterial perfusion (P < 0.05). Az of total perfusion on MR imaging was significantly larger than that of pulmonary arterial perfusion (P < 0.05). Mean OS of responder and non-responder groups were significantly different for total and systemic arterial (P < 0.05) perfusion. CONCLUSION Dynamic first-pass CE-perfusion ADCT and MR imaging as well as PET/CT are useful for early prediction of treatment response by NSCLC patients treated with chemoradiotherapy.
Collapse
Affiliation(s)
- Shinichiro Seki
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine.,Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine
| | | | | | - Yuji Kishida
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine
| | - Hisanobu Koyama
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine
| | | | | | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine.,Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine
| | - Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine.,Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine
| |
Collapse
|
14
|
Hong W, Zhang G. Simulation analysis for tumor radiotherapy based on three-component mathematical models. J Appl Clin Med Phys 2019; 20:22-26. [PMID: 30861277 PMCID: PMC6414144 DOI: 10.1002/acm2.12516] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 06/25/2018] [Accepted: 11/04/2018] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVE To setup a three-component tumor growth mathematical model and discuss its basic application in tumor fractional radiotherapy with computer simulation. METHOD First, our three-component tumor growth model extended from the classical Gompertz tumor model was formulated and applied to a fractional radiotherapy with a series of proper parameters. With the computer simulation of our model, the impact of some parameters such as fractional dose, amount of quiescent tumor cells, and α/β value to the effect of radiotherapy was also analyzed, respectively. RESULTS With several optimal technologies, the model could run stably and output a series of convergent results. The simulation results showed that the fractional radiotherapy dose could impact the effect of radiotherapy significantly, while the amount of quiescent tumor cells and α/β value did that to a certain extent. CONCLUSIONS Supported with some proper parameters, our model can simulate and analyze the tumor radiotherapy program as well as give some theoretical instruction to radiotherapy personalized optimization.
Collapse
Affiliation(s)
- Wen‐song Hong
- Radiotherapy Department of Guangdong Second Provincial General HospitalGuangzhouChina
| | - Gang‐qing Zhang
- Radiotherapy Department of Guangdong Second Provincial General HospitalGuangzhouChina
| |
Collapse
|
15
|
Ohno Y, Koyama H, Seki S, Kishida Y, Yoshikawa T. Radiation dose reduction techniques for chest CT: Principles and clinical results. Eur J Radiol 2018; 111:93-103. [PMID: 30691672 DOI: 10.1016/j.ejrad.2018.12.017] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 12/06/2018] [Accepted: 12/16/2018] [Indexed: 11/19/2022]
Abstract
Computer tomography plays a major role in the evaluation of thoracic diseases, especially since the advent of the multidetector-row CT (MDCT) technology. However, the increase use of this technique has raised some concerns about the resulting radiation dose. In this review, we will present the various methods allowing limiting the radiation dose exposure resulting from chest CT acquisitions, including the options of image filtering and iterative reconstruction (IR) algorithms. The clinical applications of reduced dose protocols will be reviewed, especially for lung nodule detection and diagnosis of pulmonary thromboembolism. The performance of reduced dose protocols for infiltrative lung disease assessment will also be discussed. Lastly, the influence of using IR algorithms on computer-aided detection and volumetry of lung nodules, as well as on quantitative and functional assessment of chest diseases will be presented and discussed.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Japan.
| | | | - Shinichiro Seki
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Japan
| | - Yuji Kishida
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Japan
| | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Japan
| |
Collapse
|
16
|
Yabuuchi H, Kawanami S, Iwama E, Okamoto I, Kamitani T, Sagiyama K, Yamasaki Y, Honda H. Prediction of Therapeutic Effect of Chemotherapy for NSCLC Using Dual-Input Perfusion CT Analysis: Comparison among Bevacizumab Treatment, Two-Agent Platinum-based Therapy without Bevacizumab, and Other Non-Bevacizumab Treatment Groups. Radiology 2017; 286:685-695. [PMID: 29059037 DOI: 10.1148/radiol.2017162204] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Purpose To determine whether dual-input perfusion computed tomography (CT) can predict therapeutic response and prognosis in patients who underwent chemotherapy for non-small cell lung cancer (NSCLC). Materials and Methods The institutional review board approved this study and informed consent was obtained. Sixty-six patients with stage III or IV NSCLC (42 men, 24 women; mean age, 63.4 years) who underwent chemotherapy were enrolled. Patients were separated into three groups: those who received chemotherapy with bevacizumab (BV) (n = 20), those who received two-agent platinum-based therapy without BV (n = 25), and those who received other non-BV treatment (n = 21). Before treatment, pulmonary artery perfusion (PAP) and bronchial artery perfusion (BAP) of the tumors were calculated. Predictors of tumor reduction after two courses of chemotherapy and prognosis were identified by using univariate and multivariate analyses. Covariates included were age, sex, patient's performance status, baseline maximum diameter of the tumor, clinical stage, pretreatment PAP, and pretreatment BAP. For multivariate analyses, multiple linear regression analysis for tumor reduction rate and Cox proportional hazards model for prognosis were performed, respectively. Results Pretreatment BAP was independently correlated with tumor reduction rate after two courses of chemotherapy in the BV treatment group (P = .006). Pretreatment BAP was significantly associated with a highly cumulative risk of death (P = .006) and disease progression after chemotherapy (P = .015) in the BV treatment group. Pretreatment PAP and clinical parameters were not significant predictors of therapeutic effect or prognosis in three treatment groups. Conclusion Pretreatment BAP derived from dual-input perfusion CT seems to be a promising tool to help predict responses to chemotherapy with BV in patients with NSCLC. © RSNA, 2017.
Collapse
Affiliation(s)
- Hidetake Yabuuchi
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Satoshi Kawanami
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Eiji Iwama
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Isamu Okamoto
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Takeshi Kamitani
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Koji Sagiyama
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Yuzo Yamasaki
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Hiroshi Honda
- From the Department of Health Sciences (H.Y.), Department of Clinical Radiology (S.K., T.K., K.S., Y.Y., H.H.), and Research Institute for Diseases of the Chest (E.I., I.O.), Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
17
|
Dynamic Contrast-Enhanced Perfusion Area-Detector CT: Preliminary Comparison of Diagnostic Performance for N Stage Assessment With FDG PET/CT in Non-Small Cell Lung Cancer. AJR Am J Roentgenol 2017; 209:W253-W262. [PMID: 28929810 DOI: 10.2214/ajr.17.17959] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of our study was to directly compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion area-detector CT (ADCT) and FDG PET/CT for differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with non-small cell lung carcinoma (NSCLC). SUBJECTS AND METHODS Seventy-seven consecutive patients, 45 men (mean age ± SD, 70.4 ± 5.9 years) and 32 women (71.2 ± 7.7 years), underwent dynamic first-pass CE-perfusion ADCT at two or three different positions for covering the entire thorax, FDG PET/CT, surgical treatment, and pathologic examination. From all ADCT data for each of the subjects, a whole-chest perfusion map was computationally generated using the dual- and single-input maximum slope and Patlak plot methods. For quantitative N stage assessment, perfusion parameters and the maximum standardized uptake value (SUVmax) for each lymph node were determined by measuring the relevant ROI. ROC curve analyses were performed for comparing the diagnostic capability of each of the methods on a per-node basis. N stages evaluated by each of the indexes were then statistically compared with the final pathologic diagnosis by means of chi-square and kappa statistics. RESULTS The area under the ROC curve (Az) values of systemic arterial perfusion (Az = 0.89), permeability surface (Az = 0.78), and SUVmax (Az = 0.85) were significantly larger than the Az values of total perfusion (Az = 0.70, p < 0.05) and distribution volume (Az = 0.55, p < 0.05). For each of the threshold values, agreement for systemic arterial perfusion calculated using the dual-input maximum slope model was substantial (κ = 0.70, p < 0.0001), and agreement for SUVmax was moderate (κ = 0.60, p < 0.0001). CONCLUSION Dynamic first-pass CE-perfusion ADCT is as useful as FDG PET/CT for the differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with NSCLC.
Collapse
|
18
|
Ito R, Iwano S, Shimamoto H, Umakoshi H, Kawaguchi K, Ito S, Kato K, Naganawa S. A comparative analysis of dual-phase dual-energy CT and FDG-PET/CT for the prediction of histopathological invasiveness of non-small cell lung cancer. Eur J Radiol 2017; 95:186-191. [PMID: 28987666 DOI: 10.1016/j.ejrad.2017.08.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/07/2017] [Accepted: 08/11/2017] [Indexed: 01/09/2023]
Abstract
PURPOSE To compare dual-phase dual-energy CT (DE-CT) with FDG-PET/CT for predicting histopathological locoregional invasiveness of non-small cell lung cancers (NSCLCs). MATERIALS AND METHODS We selected 63 consecutive patients with NSCLC lesions (37 males, 26 females; age range, 44-85 years; mean age, 69 years) who were evaluated preoperatively by both DE-CT and PET/CT at our institution. Postoperative microscopic invasiveness (lymphatic permeation, vascular invasion, and/or pleural involvement) was reviewed, and we defined locoregionally invasive tumors as those that had at least one positive finding of microscopic invasiveness. DE-CT scanning in the arterial and delayed phases was performed after injection of iodinated contrast media using 140-kVp and 80-kVp tube voltages. Three-dimensional iodine-related attenuation of primary tumors in the arterial and delayed phases was quantified automatically using "syngo Dual Energy Lung Nodules" application software, and the ratio of arterial phase to delayed phase enhancement (A/D ratio) was calculated. The A/D ratio and SUVmax on PET/CT were evaluated with respect to postoperative invasiveness by univariate logistic regression analysis. RESULTS The A/D ratio was significantly correlated with lymphatic permeation, vascular invasion, and pleural involvement (p=0.011, p=0.021, and p=0.010, respectively). In contrast, the SUVmax was significantly correlated with pleural involvement (p=0.020) but not with lymphatic permeation or vascular invasion (p=0.088 and p=0.100, respectively). In the subgroup of patients with lesion diameters ≤2cm, the A/D ratio was significantly correlated with locoregional invasiveness (p=0.040), while the SUVmax was not (p=0.121). CONCLUSION For the prediction of microscopic invasiveness of NSCLCs, the diagnostic performance of dual-phase DE-CT may be comparable to that of FDG-PET/CT.
Collapse
Affiliation(s)
- Rintaro Ito
- Nagoya University Graduate School of Medicine, Department of Radiology, 65 Tsurumai-cho, Showa-ku, Nagoya 4668550, Japan
| | - Shingo Iwano
- Nagoya University Graduate School of Medicine, Department of Radiology, 65 Tsurumai-cho, Showa-ku, Nagoya 4668550, Japan.
| | - Hironori Shimamoto
- Nagoya University Graduate School of Medicine, Department of Radiology, 65 Tsurumai-cho, Showa-ku, Nagoya 4668550, Japan
| | - Hiroyasu Umakoshi
- Nagoya University Graduate School of Medicine, Department of Radiology, 65 Tsurumai-cho, Showa-ku, Nagoya 4668550, Japan
| | - Koji Kawaguchi
- Nagoya University Graduate School of Medicine, Department of Thoracic Surgery, Japan
| | - Shinji Ito
- Nagoya University Graduate School of Medicine, Department of Radiology, 65 Tsurumai-cho, Showa-ku, Nagoya 4668550, Japan
| | - Katsuhiko Kato
- Nagoya University Graduate School of Medicine, Department of Radiological and Medical Laboratory Sciences, Japan
| | - Shinji Naganawa
- Nagoya University Graduate School of Medicine, Department of Radiology, 65 Tsurumai-cho, Showa-ku, Nagoya 4668550, Japan
| |
Collapse
|
19
|
Jiao Y, Ren Y, Zheng X. [Quantitative Imaging Assessment of Tumor Response to Chemoradiation
in Lung Cancer]. ZHONGGUO FEI AI ZA ZHI = CHINESE JOURNAL OF LUNG CANCER 2017. [PMID: 28641699 PMCID: PMC5973359 DOI: 10.3779/j.issn.1009-3419.2017.06.07] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
精准医疗的实施要求及时准确地对治疗疗效进行评估,以便于治疗方案的调整和优化,从而进一步提高疗效,改善预后。以定量评估为基础的影像组学以其无创、直观和可重复的特点在临床疗效评估方面具有不可替代的作用。本文将综述定量影像学在肺癌放化疗疗效评估中的应用现状及其相关进展。
Collapse
Affiliation(s)
- Yuxin Jiao
- Department of Radiology Oncology;Department of Radiology, Fudan University Huadong Hospital, Shanghai 200040, China
| | - Yanping Ren
- Department of Radiology Oncology, Fudan University Huadong Hospital, Shanghai 200040, China
| | - Xiangpeng Zheng
- Department of Radiology Oncology;Zhang Guozhen Diagnosis and Treatment Center of Micronodular Lung Cancer (DTC-MLC), Fudan University Huadong Hospital, Shanghai 200040, China
| |
Collapse
|
20
|
Wang Q, Zhang Z, Shan F, Shi Y, Xing W, Shi L, Zhang X. Intra-observer and inter-observer agreements for the measurement of dual-input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner-air density of tumors. Thorac Cancer 2017; 8:427-435. [PMID: 28585375 PMCID: PMC5582470 DOI: 10.1111/1759-7714.12458] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 04/19/2017] [Accepted: 04/24/2017] [Indexed: 02/06/2023] Open
Abstract
Background This study was conducted to assess intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion (DCTP) in patients with lung cancer. Methods A total of 88 patients who had undergone DCTP, which had proved a diagnosis of primary lung cancer, were divided into two groups: (i) nodules (diameter ≤3 cm) and masses (diameter >3 cm) by size, and (ii) tumors with and without air density. Pulmonary flow, bronchial flow, and pulmonary index were measured in each group. Intra‐observer and inter‐observer agreements for measurement were assessed using intraclass correlation coefficient, within‐subject coefficient of variation, and Bland–Altman analysis. Results In all lung cancers, the reproducibility coefficient for intra‐observer agreement (range 26.1–38.3%) was superior to inter‐observer agreement (range 38.1–81.2%). Further analysis revealed lower agreements for nodules compared to masses. Additionally, inner‐air density reduced both agreements for lung cancer. Conclusion The intra‐observer agreement for measuring lung cancer DCTP was satisfied, while the inter‐observer agreement was limited. The effects of tumoral size and inner‐air density to agreements, especially between two observers, should be emphasized. In future, an automatic computer‐aided segment of perfusion value of the tumor should be developed.
Collapse
Affiliation(s)
- Qingle Wang
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.,Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Medical Imaging, Shanghai Medical College, Fudan University, Shanghai, China
| | - Zhiyong Zhang
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.,Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Medical Imaging, Shanghai Medical College, Fudan University, Shanghai, China
| | - Fei Shan
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Medical Imaging, Shanghai Medical College, Fudan University, Shanghai, China.,Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Yuxin Shi
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Medical Imaging, Shanghai Medical College, Fudan University, Shanghai, China.,Department of Radiology, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Wei Xing
- Department of Radiology, Third Affiliated Hospital of Suzhou University, Suzhou, China
| | - Liangrong Shi
- Department of Oncology, Third Affiliated Hospital of Suzhou University, Suzhou, China
| | - Xingwei Zhang
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.,Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Medical Imaging, Shanghai Medical College, Fudan University, Shanghai, China
| |
Collapse
|
21
|
Ohno Y, Koyama H, Lee HY, Miura S, Yoshikawa T, Sugimura K. Contrast-enhanced CT- and MRI-based perfusion assessment for pulmonary diseases: basics and clinical applications. Diagn Interv Radiol 2017; 22:407-21. [PMID: 27523813 DOI: 10.5152/dir.2016.16123] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Assessment of regional pulmonary perfusion as well as nodule and tumor perfusions in various pulmonary diseases are currently performed by means of nuclear medicine studies requiring radioactive macroaggregates, dual-energy computed tomography (CT), and dynamic first-pass contrast-enhanced perfusion CT techniques and unenhanced and dynamic first-pass contrast enhanced perfusion magnetic resonance imaging (MRI), as well as time-resolved three-dimensional or four-dimensional contrast-enhanced magnetic resonance angiography (MRA). Perfusion scintigraphy, single-photon emission tomography (SPECT) and SPECT fused with CT have been established as clinically available scintigraphic methods; however, they are limited by perfusion information with poor spatial resolution and other shortcomings. Although positron emission tomography with 15O water can measure absolute pulmonary perfusion, it requires a cyclotron for generation of a tracer with an extremely short half-life (2 min), and can only be performed for academic purposes. Therefore, clinicians are concentrating their efforts on the application of CT-based and MRI-based quantitative and qualitative perfusion assessment to various pulmonary diseases. This review article covers 1) the basics of dual-energy CT and dynamic first-pass contrast-enhanced perfusion CT techniques, 2) the basics of time-resolved contrast-enhanced MRA and dynamic first-pass contrast-enhanced perfusion MRI, and 3) clinical applications of contrast-enhanced CT- and MRI-based perfusion assessment for patients with pulmonary nodule, lung cancer, and pulmonary vascular diseases. We believe that these new techniques can be useful in routine clinical practice for not only thoracic oncology patients, but also patients with different pulmonary vascular diseases.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology and Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan.
| | | | | | | | | | | |
Collapse
|
22
|
Multislice Analysis of Blood Flow Values in CT Perfusion Studies of Lung Cancer. BIOMED RESEARCH INTERNATIONAL 2017; 2017:3236893. [PMID: 28164118 PMCID: PMC5259676 DOI: 10.1155/2017/3236893] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Revised: 12/07/2016] [Accepted: 12/12/2016] [Indexed: 12/20/2022]
Abstract
Objectives. Tumour heterogeneity represents a key issue in CT perfusion (CTp), where all studies are usually based on global mean or median values of perfusion maps, often computed on whole tumour. We sought to determine whether, and to what extent, such global values can be representative of tumour heterogeneity, with respect to single slices, and could be used for therapy assessment. Materials and Methods. Twelve patients with one primary non-small cell lung cancer lesion were enrolled in this study, for a total amount of 26 CTp examinations and 118 slices. Mean and median blood flow (BF) values, calculated voxel-based, were computed on each slice and the whole tumour. To measure functional heterogeneity, entropy was calculated on BF values as well. Results. Most of the slices were not represented by the global BF values computed on the whole tumour. In addition, there are a number of lesions having equivalent global BF values, but they are composed of slices having very different heterogeneity distributions, that is, entropy values. Conclusions. Global mean/median BF values of the single slices separately should be considered for clinical assessment, only if interpreted through entropy computed on BF values. The numerical equivalence between global BF values of different lesions may correspond to different clinical status, thus inducing possible errors in choice of therapy when considering global values only.
Collapse
|
23
|
Ohno Y, Fujisawa Y, Koyama H, Kishida Y, Seki S, Sugihara N, Yoshikawa T. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT. Eur J Radiol 2016; 86:83-91. [PMID: 28027771 DOI: 10.1016/j.ejrad.2016.11.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 11/02/2016] [Accepted: 11/03/2016] [Indexed: 02/07/2023]
Abstract
PURPOSE To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. MATERIALS AND METHODS Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR+PR) and 2) stable or progressive disease (SD+PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUVmax, and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. RESULTS The step-wise regression test showed that therapeutic effect (r2=0.63, p=0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUVmax. Mean overall survival showed a significant difference for total perfusion (p=0.003) and systemic arterial perfusion (p=0.04). CONCLUSION Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan.
| | | | - Hisanobu Koyama
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Yuji Kishida
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Shinichiro Seki
- Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | | | - Takeshi Yoshikawa
- Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan; Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|
24
|
González-Pérez V, Arana E, Barrios M, Bartrés A, Cruz J, Montero R, González M, Deltoro C, Martínez-Pérez E, De Aguiar-Quevedo K, Arrarás M. Differentiation of benign and malignant lung lesions: Dual-Energy Computed Tomography findings. Eur J Radiol 2016; 85:1765-1772. [DOI: 10.1016/j.ejrad.2016.07.019] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 07/22/2016] [Accepted: 07/26/2016] [Indexed: 11/29/2022]
|