Kojima T, Yamasaki Y, Matsuura Y, Mikayama R, Shirasaka T, Kondo M, Kamitani T, Kato T, Ishigami K, Yabuuchi H. The Feasibility of Deep Learning-Based Reconstruction for Low-Tube-Voltage CT Angiography for Transcatheter Aortic Valve Implantation. J Comput Assist Tomogr 2024; 48:77-84. [PMID: 37574664 DOI: 10.1097/rct.0000000000001525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
OBJECTIVE The purpose of this study is to evaluate the efficacy of deep learning reconstruction (DLR) on low-tube-voltage computed tomographic angiography (CTA) for transcatheter aortic valve implantation (TAVI). METHODS We enrolled 30 patients who underwent TAVI-CT on a 320-row CT scanner. Electrocardiogram-gated coronary CTA (CCTA) was performed at 100 kV, followed by nongated aortoiliac CTA at 80 kV using a single bolus of contrast material. We used hybrid-iterative reconstruction (HIR), model-based IR (MBIR), and DLR to reconstruct these images. The contrast-to-noise ratios (CNRs) were calculated. Five-point scales were used for the overall image quality analysis. The diameter of the aortic annulus was measured in each reconstructed image, and we compared the interobserver and intraobserver agreements. RESULTS In the CCTA, the CNR and image quality score for DLR were significantly higher than those for HIR and MBIR ( P < 0.01). In the aortoiliac CTA, the CNR for DLR was significantly higher than that for HIR ( P < 0.01) and significantly lower than that for MBIR ( P ≤ 0.02). The image quality score for DLR was significantly higher than that for HIR ( P < 0.01). No significant differences were observed between the image quality scores for DLR and MBIR. The measured aortic annulus diameter had high interobserver and intraobserver agreement regardless of the reconstruction method (all intraclass correlation coefficients, >0.89). CONCLUSIONS In low tube voltage TAVI-CT, DLR provides higher image quality than HIR, and DLR provides higher image quality than MBIR in CCTA and is visually comparable to MBIR in aortoiliac CTA.
Collapse
Affiliation(s)
- Tsukasa Kojima
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital
| | | | | | | | | | - Masatoshi Kondo
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | - Toyoyuki Kato
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital
| | | | - Hidetake Yabuuchi
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
2
|
Chamberlin JH, Baruah D, Smith C, McGuire A, Maisuria D, Kabakus IM. Cardiac Computed Tomography Protocols in Structural Heart Disease: A State-of-the-Art Review. Semin Roentgenol 2024; 59:7-19. [PMID: 38388099 DOI: 10.1053/j.ro.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/23/2023] [Accepted: 12/01/2023] [Indexed: 02/24/2024]
Affiliation(s)
- Jordan H Chamberlin
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Dhiraj Baruah
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC.
| | - Carter Smith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Aaron McGuire
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Dhruw Maisuria
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Ismail M Kabakus
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| |
Collapse
|
3
|
Chatzaraki V, Kubik-Huch RA, Thali M, Niemann T. Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods. Acta Radiol 2021; 63:1353-1362. [PMID: 34647842 DOI: 10.1177/02841851211041813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. PURPOSE To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. MATERIAL AND METHODS A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. RESULTS The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. CONCLUSION We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
Collapse
Affiliation(s)
- Vasiliki Chatzaraki
- Institute of Radiology, Kantonsspital Baden, Baden, Switzerland
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | | | - Michael Thali
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Tilo Niemann
- Institute of Radiology, Kantonsspital Baden, Baden, Switzerland
| |
Collapse
|
4
|
Image quality and diagnostic performance evaluation in transcatheter aortic valve implantation candidates with atrial fibrillation using a whole-heart coverage CT scanner. Eur Radiol 2021; 32:1034-1043. [PMID: 34338842 DOI: 10.1007/s00330-021-08187-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 06/09/2021] [Accepted: 06/29/2021] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To evaluate the image quality and diagnostic performance for obstructive coronary artery disease of transcatheter aortic valve implantation (TAVI) patients with atrial fibrillation (AF) during TAVI planning CT using a whole-heart coverage CT scanner. METHODS Eighty-eight consecutive TAVI candidates with AF (50 men, 74 ± 6 years) who underwent both TAVI planning CT and invasive coronary catheter angiography (ICA) were retrospectively analyzed. With ICA results as the reference standard, the accuracy of TAVI planning CT for lesion detection on a per-vessel and per-patient level was calculated. Meanwhile, image quality, contrast volume, and effective dose (ED) were evaluated. A 5-point visual scale (1-5) was used to assess the subjective image quality. The CT value and signal-to-noise ratio were measured for the left main coronary artery (LM), left anterior descending (LAD), left circumflex (LCX), and right coronary arteries (RCA). RESULTS The ED for CCTA was 3.25 ± 1.39 mSv and contrast volume was 58.14 ± 12.34 mL. A total of 1371 (1371/1408 = 97.4%) segments with diameter > 1.5 mm were analyzed. For the subjective evaluation, the mean score was 3.99 ± 0.96 for overall image quality. The mean CT values in LM, RCA, LCX, and LAD were all above 400 HU. For the detection of > 50% stenosis, TAVI planning CT provided on the per-vessel and per-patient basis 97.06% and 100% in sensitivity, 96.23% and 89.06% in specificity, 99.7% and 100% in negative predictive value, and 73.3% and 77.4% in positive predictive value, respectively. CONCLUSION TAVI planning CT with whole-heart coverage demonstrates good CCTA image quality and a high sensitivity and NPV in excluding obstructive CAD in TAVI candidates with AF. KEY POINTS • Transcatheter aortic valve implantation planning (TAVI) CT with whole-heart coverage enables good image quality of CCTA in TAVI candidates with atrial fibrillation. • Obstructive coronary artery disease may be excluded with high accuracy in transcatheter aortic valve implantation (TAVI) candidates with atrial fibrillation with the usage of whole-heart coverage TAVI planning CT.
Collapse
|
5
|
Villecourt A, Faroux L, Blanpain T, Kinnel M, Mora C, Tassan-Mangina S, Heroguelle V, Nazeyrollas P, Metz D. Exposure to Ionizing Radiation in Patients Undergoing Transfemoral Transcatheter Aortic Valve Implantation. Am J Cardiol 2020; 125:114-119. [PMID: 31699362 DOI: 10.1016/j.amjcard.2019.09.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 09/16/2019] [Accepted: 09/17/2019] [Indexed: 11/17/2022]
Abstract
Transcatheter aortic valve implantation (TAVI) is currently becoming an alternative to surgical valve replacement for patients at low risk, a population that is likely to experience an increase in the radiation-induced cancer risk following TAVI. We aimed to evaluate the overall exposure to ionizing radiation in patients who underwent transfemoral TAVI, including the procedure itself as well as the procedures performed in the preintervention work-up and the post-TAVI interventions. All patients who underwent transfemoral TAVI for symptomatic aortic stenosis in our center over a 26 months period were included. Dosimetric indicators from preprocedural coronary angiography and computed tomography (CT), the TAVI procedure, and any postprocedural interventions (electrophysiology study and/or pacemaker implantation) were collected and converted into an effective dose. A total of 119 transfemoral TAVI procedures were included. The mean cumulative effective dose (ED) was 37.3 mSv. Three irradiating procedures were necessary for 84 patients (71% of the population, i.e., coronary angiography, CT scan and the TAVI procedure itself), whereas 30 patients (25%) required a fourth procedure, and 5 required a fifth (4%). The majority of the dose was from the CT, while only 11% of the dose derived from the TAVI procedure itself. In conclusion, overall exposure to ionizing radiation for patients who underwent transfemoral TAVI seems acceptable, and the majority of the overall ED comes from the CT scan.
Collapse
Affiliation(s)
| | - Laurent Faroux
- Department of Cardiology, Reims University Hospital, Reims, France.
| | - Thierry Blanpain
- Department of Cardiology, Reims University Hospital, Reims, France; Department of Radiation Protection, Reims University Hospital, Reims, France
| | - Marine Kinnel
- Department of Cardiology, Reims University Hospital, Reims, France
| | - Caroline Mora
- Department of Radiology, Reims University Hospital, Reims, France
| | | | | | | | - Damien Metz
- Department of Cardiology, Reims University Hospital, Reims, France
| |
Collapse
|
6
|
Onoda H, Ueno H, Hashimoto M, Kuwahara H, Sobajima M, Kinugawa K. Clinical Advantages of Using Low Tube Voltage in Third-Generation 192-Slice Dual-Source Computed Tomographic Angiography Before Transcatheter Aortic Valve Implantation. Int Heart J 2019; 60:1091-1097. [PMID: 31484865 DOI: 10.1536/ihj.18-693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Low-voltage computed tomographic angiography (CTA) is a highly effective technique to reduce contrast media volume. We sought to examine the suitability of low tube voltage CTA with a reduced contrast media volume protocol using third-generation 192-slice dual-source CT in patients undergoing transcatheter aortic valve implantation (TAVI). CTA was performed to aid TAVI planning for 40 consecutive patients with severe aortic stenosis. For the first 10 patients (120/100 kV group), we used a conventional tube voltage combined CTA protocol (an ECG-gated helical scan; 120 kV, non-gated helical scan; 100 kV). For the subsequent 30 patients (70-kV group), we adopted a low tube voltage CTA protocol. We evaluated vascular attenuation, image noise, contrast-to-noise ratio (CNR), and renal function. The mean contrast media (CM) volume was 77.7 ± 17.7 mL in the 120/100-kV group and 30.9 ± 6.3 mL in the 70-kV group (P < 0.001). In the images of the aortic valve complex, the mean attenuation was not significant difference for both groups. In the images of the aorto-femoral arteries, mean attenuation was > 250 Hounsfield Units and CNR was > 10 in all vascular segments for both groups. There was no significant difference in the change of renal function in the 70-kV group, but renal function in the 120/100-kV group decreased within 1-3 months after CTA. Low tube voltage CTA using third-generation dual-source CT is suitable to assess procedural planning for TAVI. This approach maintains image quality and reduces the required CM volume.
Collapse
Affiliation(s)
- Hiroshi Onoda
- Second Department of Internal Medicine, University of Toyama
| | - Hiroshi Ueno
- Second Department of Internal Medicine, University of Toyama
| | | | | | - Mitsuo Sobajima
- Second Department of Internal Medicine, University of Toyama
| | | |
Collapse
|
7
|
Radiation dose reduction using two orthogonal topograms associated with automatic tube voltage selection for lung CT scanning as compared with a single anteroposterior topogram. Jpn J Radiol 2019; 37:292-300. [PMID: 30603833 DOI: 10.1007/s11604-018-00809-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Accepted: 12/19/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVE To evaluate the effectiveness of two orthogonal topograms on radiation dose and image quality (IQ) associated with topogram-based automatic tube voltage selection (ATVS) for lung CT scanning. METHODS Thirty-seven patients were enrolled in this study. At baseline, only an anteroposterior topogram was obtained and at follow-up, both anteroposterior and lateral topograms were performed. ATVS was turned on during all scans. Objective and subjective IQ evaluations were performed and compared; tube voltage and radiation dose of each scan were noted and analyzed. RESULTS A significant difference was observed regarding the objective parameters between baseline and follow-up only in image noise and signal-noise ratio (SNR) in the upper one-third of the image (image noise: 7.49 ± 1.08 vs. 9.10 ± 1.13, p < 0.001; SNR: 4.08 ± 0.87 vs. 3.37 ± 0.63, p < 0.001). No differences were found between baseline and follow-up in the subjective assessment of IQ. The radiation dose was significantly lower at follow-up than that at baseline (2.73 ± 0.83 mSv vs. 3.55 ± 1.24 mSv, respectively; p < 0.001). CONCLUSIONS Using two orthogonal topograms associated with ATVS could significantly reduce the total radiation dose for lung CT scanning, while subjective IQ was maintained.
Collapse
|
8
|
Technical Feasibility of a Combined Noncontrast Magnetic Resonance Protocol for Preoperative Transcatheter Aortic Valve Replacement Evaluation. J Thorac Imaging 2018; 33:60-67. [PMID: 28549023 DOI: 10.1097/rti.0000000000000278] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE The aim of this study was to prospectively evaluate the technical feasibility of a noncontrast magnetic resonance angiography (MRA) protocol using investigational prototype self-navigated 3D (SN3D) radial whole-heart and quiescent-interval single-shot (QISS) pulse sequences regarding their potential in planning transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS Five patients (76±7 y) with severe aortic valve stenosis and prior computed tomographic angiography (CTA) for TAVR planning and 10 healthy volunteers (28±6 y) underwent noncontrast MRA on a 1.5 T system. A SN3D whole-heart acquisition was used to assess the aortic root anatomy. Evaluation of the aortoiliac access route was performed with both SN3D and QISS. Measurements were compared among SN3D, QISS, and CTA using a paired t test or 1-way analysis of variance. Image quality ratings and contrast-to-noise ratios (CNR) were analyzed using Mann-Whitney U tests. Interobserver agreement was evaluated using Cohen's κ. RESULTS The combined SN3D and QISS protocol provided a 10.1±1.6-minute acquisition time. TAVR-relevant evaluation was technically feasible in healthy volunteers. All measurements showed good agreement with CTA in patients (all P>0.098). SN3D and QISS produced similar image quality both in volunteers and in patients (all P>0.122). There was no difference in qualitative ratings between MRA and CTA (all P>0.119). Interobserver agreement was good for MRA (κ=0.71 to 0.76) and excellent for CTA (κ=0.82 to 0.84). Thoracic SN3D provided a similar CNR compared with CTA (P=0.117). CTA yielded higher CNR in the abdominopelvic region compared with QISS (P=0.006). CONCLUSIONS A noncontrast MRA protocol combining SN3D and QISS acquisitions for the assessment of cardiac and vascular access route anatomy has technical feasibility for TAVR planning.
Collapse
|
9
|
Albrecht MH, Bickford MW, Schoepf UJ, Tesche C, De Santis D, Eid M, Jacobs BE, Duguay TM, Schmidt BT, Canstein C, Varga-Szemes A, Leithner D, Martin S, Vogl TJ, De Cecco CN. Beam-hardening in 70-kV Coronary CT angiography: Artifact reduction using an advanced post-processing algorithm. Eur J Radiol 2018; 101:111-117. [DOI: 10.1016/j.ejrad.2018.02.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 09/27/2017] [Accepted: 02/12/2018] [Indexed: 10/18/2022]
|
10
|
High-Pitch Coronary Computed Tomographic Angiography Using the Third-Generation Dual-Source Computed Tomography. J Comput Assist Tomogr 2018; 42:248-255. [DOI: 10.1097/rct.0000000000000678] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
11
|
Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol. Eur Radiol 2017; 28:2134-2142. [PMID: 29181587 DOI: 10.1007/s00330-017-5150-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 09/07/2017] [Accepted: 10/18/2017] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.
Collapse
|