1
|
Fu W, Ma Z, Yang Z, Yu S, Zhang Y, Zhang X, Mei B, Meng Y, Ma C, Gong X. Fully automated image quality assessment based on deep learning for carotid computed tomography angiography: A multicenter study. Phys Med 2025; 134:104990. [PMID: 40347553 DOI: 10.1016/j.ejmp.2025.104990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 04/01/2025] [Accepted: 04/29/2025] [Indexed: 05/14/2025] Open
Abstract
PURPOSE To develop and evaluate the performance of fully automated model based on deep learning and multiple logistics regression algorithm for image quality assessment (IQA) of carotid computed tomography angiography (CTA) images. METHODS This study retrospectively collected 840 carotid CTA images from four tertiary hospitals. Three radiologists independently assessed the image quality using a 3-point Likert scale, based on the degree of noise, vessel enhancement, arterial vessel contrast, vessel edge sharpness, and overall diagnostic acceptability. An automated assessment model was developed using a training dataset consisting of 600 carotid CTA images. The assessment steps included: (i) selection of objective representative slices; (ii) use of 3D Res U-net approach to extract objective indices from the representative slices and (iii) use of single objective index and multiple indices combinedly to develop logistic regression models for IQA. In the internal and external test datasets (n = 240), the performance of models was evaluated using sensitivity, specificity, precision, F-score, accuracy, the area under the receiver operating characteristic curve (AUC), and the IQA results of models was compared with radiologists' consensus. RESULTS The representative slices were determined based on the same length model. The performance of multi-index model was excellent in internal and external test datasets with AUCs of 0.98 and 0.97. And the consistency between model and radiologists achieved 91.8% (95% CI: 87.0-96.5) and 92.6% (95 % CI: 86.9-98.4) in internal and external test datasets respectively. CONCLUSION The fully automated multi-index model showed equivalent performance to the subjective perceptions of radiologists with greater efficiency for IQA.
Collapse
Affiliation(s)
- Wanyun Fu
- Rehabilitation Medicine Center, Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou 310014, Zhejiang, China.; The Second School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou 310053 Zhejiang, China
| | - Zhangman Ma
- The Second School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou 310053 Zhejiang, China
| | - Zhiwen Yang
- ShuKun Technology Co., Ltd., Jinhui Bd, Qiyang Rd, Beijing 100029, China
| | - Shufeng Yu
- Rehabilitation Medicine Center, Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou 310014, Zhejiang, China
| | - Yongsheng Zhang
- Department of Radiology, Hangzhou TCM Hospital Affiliated to Zhejiang Chinese Medical University, China
| | - Xinsheng Zhang
- The Second School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou 310053 Zhejiang, China
| | - Bozhe Mei
- Jinzhou Medical University, Jinzhou, Liaoning Province, China
| | - Yu Meng
- Rehabilitation Medicine Center, Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou 310014, Zhejiang, China
| | - Chune Ma
- ShuKun Technology Co., Ltd., Jinhui Bd, Qiyang Rd, Beijing 100029, China
| | - Xiangyang Gong
- Rehabilitation Medicine Center, Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou 310014, Zhejiang, China.; Institute of Artificial Intelligence and Remote Imaging, Hangzhou Medical College, Hangzhou 310014, China.
| |
Collapse
|
2
|
Lin DC, Tsai PS, Lin TL, Huang WH, Liu YP, Wu TH, Shih CT. Predicting complications and morbidities in PAD patients through lower extremity compositions with dual-energy CT and material decomposition: a 2-year follow-up observational study. BMC Cardiovasc Disord 2025; 25:268. [PMID: 40197259 PMCID: PMC11977887 DOI: 10.1186/s12872-025-04695-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/21/2025] [Indexed: 04/10/2025] Open
Abstract
BACKGROUND Peripheral artery disease (PAD) is associated with various morbidities. This study aims to investigate the correlation between different lower extremity compositions and development of morbidities in PAD patients. METHODS Between January 2018 and December 2020, 108 subjects diagnosed of PAD were enrolled (mean age of 64.1 ± 13.5 years) and utilized dual-energy computed tomography (DECT) with material decomposition to measure the vessel volume, muscle volume, fat volume, and cortical-bone volume in lower extremity respectively. The association between each leg composition and developing complications or morbidities in PAD patients was analyzed over a two-year follow-up. RESULTS Fontaine stage 3 and 4 had lower muscle mass compared to stages 1 and 2. More severe vascular stenosis was associated with lower muscle, fat, and cortical-bone volume. Patients with severe Fontaine stages (3 and 4) and lower-leg vascular stenosis had a higher risk of developing infection or inflammation (OR 45.5, 95% CI: 13.5-166.7, and OR 11.7, 95% CI: 2.8-50, P < 0.05) and amputation (OR 18.2, 95% CI: 2.2-142.8, and OR 10.7, 95% CI: 1.11-100, P < 0.05). Lower thigh cortical-bone volume was associated with an increased risk of falls resulting in fractures (OR: 1.39, 95% CI: 1.13-2.19, P < 0.01). Thigh cortical-bone volume below 64.5 cm3 was identified as the cut-off value to predict fall-related fractures, with a sensitivity of 100% and specificity of 92%. CONCLUSIONS This study demonstrates the potential of DECT with material decomposition to assess lower extremity composition and its relevance in predicting complications and morbidities in PAD patients. Severe vascular stenosis may contribute to muscle wasting and subsequent complications, while lower thigh cortical-bone mass may serve as a predictor of fall-related fractures.
Collapse
Affiliation(s)
- Dao-Chen Lin
- Department of Radiology, Taipei Veterans General Hospital, Taipei City, Taiwan
- Division of Endocrine and Metabolism, Department of Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan
| | - Pei-Shan Tsai
- Department of Radiology, MacKay Memorial Hospital, Taipei City, Taiwan
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan
- Department of Medicine, Mackay Medical College, New Taipei City, Taiwan
- Nursing and Management, Mackay Junior College of Medicine, Taipei City, Taiwan
| | - Tzu-Lin Lin
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan
| | - Wen-Hui Huang
- Department of Radiology, MacKay Memorial Hospital, Taipei City, Taiwan
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan
- Department of Medicine, Mackay Medical College, New Taipei City, Taiwan
- Nursing and Management, Mackay Junior College of Medicine, Taipei City, Taiwan
| | - Yu-Peng Liu
- Nursing and Management, Mackay Junior College of Medicine, Taipei City, Taiwan
- Department of Radiology, Hsinchu Mackay Memorial Hospital, Hsinchu City, Taiwan
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan
| | - Cheng-Ting Shih
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung City, Taiwan.
| |
Collapse
|
3
|
Rippel K, Decker JA, Luitjens J, Habeeballah O, Bette S, Braun F, Kroencke TJ, Scheurig-Muenkler C. Virtual Monoenergetic Imaging of Thoracoabdominal Computed Tomography Angiography on Photon-Counting Detector Computertomography: Assessment of Image Quality and Leveraging Low-keV Series for Salvaging Suboptimal Contrast Acquisitions. Diagnostics (Basel) 2024; 14:2843. [PMID: 39767204 PMCID: PMC11675690 DOI: 10.3390/diagnostics14242843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 12/07/2024] [Accepted: 12/11/2024] [Indexed: 01/11/2025] Open
Abstract
BACKGROUND The aim of this study was to assess the possibility of image improvement of ECG-gated, high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta before transaortic valve replacement (TAVR) on a novel dual-source photon-counting detector CT (PCD-CT) in the setting of suboptimal low-contrast attenuation. METHODS Continuously examined patients who underwent an ECG-gated, high-pitch CTA of the aorta on a PCD-CT with a contrast decrease of at least 50% between the ascending aorta and the common femoral arteries (CFA) were included. Patient characteristics were documented. Virtual monoenergetic imaging (VMI) reconstructions with three keV settings were generated. CT values and noise were measured for five vascular segments of the aorta and the CFA. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Two independent board-certified radiologists rated the images with the focus on vascular attenuation, vessel sharpness, and image quality using a 5-point Likert scale. RESULTS Fifty-five patients (mean age 77.4 ± 8.5 years; 15 women) were included. The SNR was significantly higher at 40 and 45 keV VMI compared to reference 70 keV (p < 0.001 and p = 0.005, respectively). The same was shown for the CNR (p < 0.001 and p = 0.0049, respectively). Subjective image evaluation showed a significant increase in vessel attenuation in the lower keV reconstructions, while the overall image quality decreased only slightly. Furthermore, 50% (8/16) of primarily non-diagnostic scans were considered diagnostic when using low-keV reconstructions (p > 0.05). CONCLUSIONS ECG-gated CTA of the aorta in high-pitch mode on PCD-CT with suboptimal contrast enhancement at the level of the CFA can be salvaged by using low-keV VMI. This implies the possibility of radiation dose reduction by eliminating the need for repeat scans.
Collapse
Affiliation(s)
- Katharina Rippel
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| | - Josua A. Decker
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| | - Jan Luitjens
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| | - Osama Habeeballah
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| | - Stefanie Bette
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| | - Franziska Braun
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| | - Thomas J. Kroencke
- Centre for Advanced Analytics and Predictive Sciences (CAAPS), University of Augsburg, Universitätsstr. 2, 86159 Augsburg, Germany
| | - Christian Scheurig-Muenkler
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
| |
Collapse
|
4
|
Booz C, Bucolo GM, D'Angelo T, Mazziotti S, Lanzafame LRM, Yel I, Alizadeh LS, Gruenewald LD, Koch V, Martin SS, Dimitrova M, Goekduman A, Vogl TJ, Kaatsch HL, Overhoff D, Waldeck S. Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability. LA RADIOLOGIA MEDICA 2024; 129:1633-1643. [PMID: 39287697 PMCID: PMC11554704 DOI: 10.1007/s11547-024-01889-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 09/12/2024] [Indexed: 09/19/2024]
Abstract
PURPOSE Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. MATERIALS AND METHODS A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery. RESULTS Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) (p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01). CONCLUSIONS Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.
Collapse
Affiliation(s)
- Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Giuseppe M Bucolo
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Tommaso D'Angelo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy.
- Department of Radiology and Nuclear Medicine, Erasmus MC, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
| | - Silvio Mazziotti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Ludovica R M Lanzafame
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital "Policlinico G. Martino", Via Consolare Valeria 1, 98100, Messina, Italy
| | - Ibrahim Yel
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Leona S Alizadeh
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072, Koblenz, Germany
| | - Leon D Gruenewald
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Vitali Koch
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Simon S Martin
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Mirela Dimitrova
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Aynur Goekduman
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Thomas J Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Hanns L Kaatsch
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072, Koblenz, Germany
| | - Daniel Overhoff
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072, Koblenz, Germany
- Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Centre Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Stephan Waldeck
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072, Koblenz, Germany
- Department of Neuroradiology, University Medical Center Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
5
|
Chatterjee AR, Malhotra A, Curl P, Andre JB, Perez-Carrillo GJG, Smith EB. Traumatic Cervical Cerebrovascular Injury and the Role of CTA: AJR Expert Panel Narrative Review. AJR Am J Roentgenol 2024; 223:e2329783. [PMID: 37791730 DOI: 10.2214/ajr.23.29783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/05/2023]
Abstract
Traumatic cerebrovascular injury (CVI) involving the cervical carotid and vertebral arteries is rare but can lead to stroke, hemodynamic compromise, and mortality in the absence of early diagnosis and treatment. The diagnosis of both blunt cerebrovascular injury (BCVI) and penetrating CVI is based on cerebrovascular imaging. The most commonly used screening criteria for BCVI include the expanded Denver criteria and the Memphis criteria, each providing varying thresholds for subsequent imaging. Neck CTA has supplanted catheter-based digital subtraction angiography as the preferred screening modality for CVI in patients with trauma. This AJR Expert Panel Narrative Review describes the current state of CTA-based cervical imaging in trauma. We review the most common screening criteria for BCVI, discuss BCVI grading scales that are based on neck CTA, describe the diagnostic performance of CTA in the context of other imaging modalities and evolving treatment strategies, and provide a practical guide for neck CTA implementation.
Collapse
Affiliation(s)
- Arindam Rano Chatterjee
- Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, 510 S Kingshighway, Box 8131, St. Louis, MO 63110
| | - Ajay Malhotra
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT
| | - Patti Curl
- Department of Radiology, Neuroradiology Section, University of Washington School of Medicine, Seattle, WA
| | - Jalal B Andre
- Department of Radiology, Neuroradiology Section, University of Washington School of Medicine, Seattle, WA
| | - Gloria J Guzman Perez-Carrillo
- Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, 510 S Kingshighway, Box 8131, St. Louis, MO 63110
| | - Elana B Smith
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD
| |
Collapse
|
6
|
Rippel K, Luitjens J, Habeeballah O, Scheurig-Muenkler C, Bette S, Braun F, Kroencke TJ, Schwarz F, Decker JA. Evaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography. J Endovasc Ther 2024:15266028241230943. [PMID: 38380529 DOI: 10.1177/15266028241230943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
PURPOSE The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector-CT (PCD-CT) in comparison with an energy-integrating detector-CT (EID-CT), with a special focus on low-contrast attenuation. METHODS Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. RESULTS Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. CONCLUSION The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. CLINICAL IMPACT ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.
Collapse
Affiliation(s)
- K Rippel
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| | - J Luitjens
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| | - O Habeeballah
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| | - C Scheurig-Muenkler
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| | - Stefanie Bette
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| | - Franziska Braun
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| | - T J Kroencke
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
- Centre for Advanced Analytics and Predictive Sciences, University of Augsburg, Augsburg, Germany
| | - F Schwarz
- DONAUISAR Klinikum Deggendorf, Deggendorf, Germany
| | - J A Decker
- Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Augsburg, Germany
| |
Collapse
|
7
|
Yuan D, Li L, Zhang Y, Qi K, Zhang M, Zhang W, Lyu P, Zhang Y, Gao J, Liu J. Image quality improvement in head and neck CT angiography: Individualized post-trigger delay versus fixed delay. Eur J Radiol 2023; 168:111142. [PMID: 37832195 DOI: 10.1016/j.ejrad.2023.111142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 09/27/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023]
Abstract
PURPOSE To compare the contrast media opacification of head and neck CT angiography (CTA) between conventional fixed trigger delay and individualized post-trigger delay (PTD). METHODS In this prospective study (April-October 2022), 196 consecutive participants were randomly divided into two groups to perform head and neck CTA in bolus tracking with either an individualized PTD (Group A) or a fixed 4-second PTD (Group B). All CT and contrast media protocol parameters were consistent between the two groups. One reader evaluated objective image quality, while two readers rated subjective image quality. Objective image quality was compared between groups via two-sample t-test, while the subjective ratings were compared with chi-square analysis. RESULTS Participants' clinical information including sex, age, weight, body weight index (BMI), and heart rate were not statistically different between two groups (all p > 0.05). Individualized PTD ranging from 3.5 to 7.9 s (average 5.6 s), which is shorter than fixed delays (p < 0.05). Both readers rated better subjective image quality for the Group A (p < 0.05). The mean vessel enhancement was significantly higher in Group A in all vessels (all p < 0.05). CONCLUSIONS Compared to the fixed post-trigger delay in bolus tracking technique, individualized post-trigger delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality for head and neck CT angiography.
Collapse
Affiliation(s)
- Dian Yuan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Linfeng Li
- Siemens Healthineers GmbH, Forchheim, Germany
| | - Yicun Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Ke Qi
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Mengyuan Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Weiting Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Peijie Lyu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yonggao Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China.
| |
Collapse
|
8
|
Zhao J, Cheng Q, Liu C, Wang Q, Lv Y, Tang Z, Luo Y, Yang H. Optimal combination periprosthetic vasculature visualization and metal artifact reduction by spectral computed tomography using virtual monoenergetic images in total hip arthroplasty. Insights Imaging 2023; 14:181. [PMID: 37880460 PMCID: PMC10600072 DOI: 10.1186/s13244-023-01533-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 09/29/2023] [Indexed: 10/27/2023] Open
Abstract
OBJECTIVES To investigate the optimal parameters of spectral CT for preferably visualizing the periprosthetic vasculature and metal artifact reduction (MAR) in total hip arthroplasty (THA). METHODS A total of 34 THA of 30 patients were retrospectively included. Image reconstructions included conventional image (CI), CI combined with MAR (CIMAR), and virtual monoenergetic images (VMI) combined with MAR (VMIMAR) at 50-120 keV. The attenuation and standard deviation of the vessel and artifact, and the width of artifact were measured. Qualitative scoring was evaluated including the vascular contour, the extent of artifact, and overall diagnostic evaluation. RESULTS The attenuation, noise of the vessel and artifact, and the width of artifact decreased as the energy level increased (p < 0.001). The downtrend was relatively flat at 80-120 keV, and the vascular attenuation dropped to 200 HU at 90 keV. The qualitative rating of vascular contour was significantly higher at CIMAR (3.47) and VMIMAR 60-80 keV (2.82-3.65) compared with CI (2.03) (p ≤ 0.029), and the highest score occurred at 70 and 80 keV (3.65 and 3.56). The score of the extent of artifact was higher at VMIMAR 80 keV than CIMAR (3.53 VS 3.12, p = 0.003). The score of the overall diagnostic evaluation was higher at VMIMAR 70 and 80 keV (3.32 and 3.53, respectively) than CIMAR (3.12) (p ≤ 0.035). CONCLUSION Eighty kiloelectron volts on VMIMAR, providing satisfactorily reduced metal artifacts and improved vascular visualization, can be an optimal recommended parameter of spectrum CT for the assessment of periprosthetic vasculature in THA patients. CRITICAL RELEVANCE STATEMENT The metal artifact is gradually reducing with increasing energy level; however, the vascular visualization is worsening. The vascular visualization is terrible above 100 keV, while the vessel is disturbed by artifacts below 70 keV. The best performance is found at 80 keV. KEY POINTS • VMIMAR can provide both reduced metal artifacts and improved vascular visualization. • Eighty kiloelectron volts on VMIMAR performs best in vascular visualization of total hip arthroplasty patients. • Energy spectrum CT is recommended for routine use in patients with total hip arthroplasty.
Collapse
Affiliation(s)
- Jie Zhao
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Qiang Cheng
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Chuan Liu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Qiqi Wang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Yuchan Lv
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Ziyi Tang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Yuxi Luo
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China
| | - Haitao Yang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Yuzhong District, Chongqing, 400016, China.
| |
Collapse
|
9
|
Kazimierczak W, Nowak E, Kazimierczak N, Jankowski T, Jankowska A, Serafin Z. The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair. Heliyon 2023; 9:e20700. [PMID: 37876478 PMCID: PMC10590777 DOI: 10.1016/j.heliyon.2023.e20700] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 10/04/2023] [Accepted: 10/04/2023] [Indexed: 10/26/2023] Open
Abstract
Rationale and objectives Evaluation of the diagnostic value of linearly blended (LB) and virtual monoenergetic images (VMI) reconstruction techniques with and without metal artifacts reduction (MAR) and of adaptive statistical iterative reconstructions (ASIR) in the assessment of target vessels after branched/fenestrated endovascular aortic repair (f/brEVAR) procedures. Materials and methods CT scans of 28 patients were used in this study. Arterial phase of examination was obtained using a dual-energy fast-kVp switching scanner. CT numbers in the aorta, celiac trunk, superior mesenteric artery, and renal arteries were measured in the following reconstructions: LB, VMI 60 keV, VMI MAR 60 keV, VMI ASIR 60 % 60 keV. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated for each reconstruction. Luminal diameters (measurements at 2 levels of stent) and subjective image quality (5-point Likert scale) were assessed (2 readers, blinded to the type of reconstruction). Results The highest mean values of CNR and SNR in vascular structures were obtained in VMI MAR 60 keV (CNR 12.526 ± 2.46, SNR 17.398 ± 2.52), lower in VMI 60 keV (CNR 11.508 ± 2.01, SNR 16.524 ± 2.07) and VMI ASIR (CNR 11.086 ± 1.78, SNR 15.928 ± 1.82), and the lowest in LB (CNR 6.808 ± 0.79, SNR 11.492 ± 0.79) reconstructions. There were no statistically significant differences in the measurements of the stent width between reconstructions (p > 0.05). The highest subjective image quality was obtained in the ASIR VMI (4.25 ± 0.44) and the lowest in the MAR VMI (1.57 ± 0.5) reconstruction. Conclusion Despite obtaining the highest values of SNR and CNR in the MAR VMI reconstruction, the subjective diagnostic value was the lowest for this technique due to significant artifacts. The type of reconstruction did not significantly affect vessel diameter measurements (p > 0.05). Iterative reconstructions raised both objective and subjective image quality.
Collapse
Affiliation(s)
- Wojciech Kazimierczak
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej – Curie 9, 85-094, Bydgoszcz, Poland
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009, Bydgoszcz, Poland
| | - Ewa Nowak
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej – Curie 9, 85-094, Bydgoszcz, Poland
| | - Natalia Kazimierczak
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009, Bydgoszcz, Poland
| | - Tomasz Jankowski
- Jankowscy Private Dental Practice, Czerwonego Krzyża 24, 68-200, Żary, Poland
| | - Agnieszka Jankowska
- Jankowscy Private Dental Practice, Czerwonego Krzyża 24, 68-200, Żary, Poland
| | - Zbigniew Serafin
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej – Curie 9, 85-094, Bydgoszcz, Poland
| |
Collapse
|
10
|
D’Angelo T, Lanzafame LRM, Micari A, Blandino A, Yel I, Koch V, Gruenewald LD, Vogl TJ, Booz C, Bucolo GM, Cannizzaro MT, Ascenti G, Mazziotti S. Improved Coronary Artery Visualization Using Virtual Monoenergetic Imaging from Dual-Layer Spectral Detector CT Angiography. Diagnostics (Basel) 2023; 13:2675. [PMID: 37627934 PMCID: PMC10453590 DOI: 10.3390/diagnostics13162675] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 08/07/2023] [Accepted: 08/09/2023] [Indexed: 08/27/2023] Open
Abstract
Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72-0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.
Collapse
Affiliation(s)
- Tommaso D’Angelo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
- Department of Radiology and Nuclear Medicine, Erasmus MC, 3015 GD Rotterdam, The Netherlands
| | - Ludovica R. M. Lanzafame
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Antonino Micari
- Department of Clinical and Experimental Medicine, DIMED, University Hospital Messina, 98124 Messina, Italy;
| | - Alfredo Blandino
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Ibrahim Yel
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Vitali Koch
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Leon D. Gruenewald
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Thomas J. Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Giuseppe M. Bucolo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Maria Teresa Cannizzaro
- Radiology Unit (CAST), University Hospital Catania, “Policlinico G. Rodolico–San Marco”, 95123 Catania, Italy;
| | - Giorgio Ascenti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Silvio Mazziotti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| |
Collapse
|
11
|
Bucolo GM, D’Angelo T, Yel I, Koch V, Gruenewald LD, Othman AE, Alizadeh LS, Overhoff DP, Waldeck S, Martin SS, Mazziotti S, Ascenti G, Blandino A, Vogl TJ, Booz C. Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus. Diagnostics (Basel) 2023; 13:1790. [PMID: 37238274 PMCID: PMC10217432 DOI: 10.3390/diagnostics13101790] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/11/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions. PURPOSE To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. MATERIALS AND METHODS We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast. RESULTS Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001). CONCLUSIONS DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.
Collapse
Affiliation(s)
- Giuseppe Mauro Bucolo
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Tommaso D’Angelo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
- Department of Radiology and Nuclear Medicine, Erasmus MC, 3015 GD Rotterdam, The Netherlands
| | - Ibrahim Yel
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Vitali Koch
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Leon D. Gruenewald
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Ahmed E. Othman
- Department of Neuroradiology, University Hospital Mainz, 55131 Mainz, Germany
| | - Leona Soraja Alizadeh
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, 56072 Koblenz, Germany
| | - Daniel P. Overhoff
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, 56072 Koblenz, Germany
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Heidelberg University, 68167 Mannheim, Germany
| | - Stephan Waldeck
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, 56072 Koblenz, Germany
- Institute of Neuroradiology, University Medical Centre, Johannes Gutenberg University Mainz, 55099 Mainz, Germany
| | - Simon S. Martin
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Silvio Mazziotti
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Giorgio Ascenti
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Alfredo Blandino
- Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Thomas J. Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| |
Collapse
|
12
|
Dai Y, Xu H, Fang X, Xiong X, Song Z, Hu S, Yu Y, Hu C, Zhang Y. Dual-energy CT in assessment of thrombus perviousness and its application in predicting outcomes after intravenous thrombolysis in acute ischemic stroke. Eur J Radiol 2023; 164:110861. [PMID: 37167682 DOI: 10.1016/j.ejrad.2023.110861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 04/02/2023] [Accepted: 05/02/2023] [Indexed: 05/13/2023]
Abstract
PURPOSE To evaluate the feasibility of using iodine overlay maps reconstructed from dual-energy CT (DECT) to assess thrombus perviousness and investigate its value in predicting outcomes after intravenous thrombolysis in patients with acute ischemic stroke. METHOD 86 patients with proximal intracranial occlusions of the anterior circulation who underwent intravenous thrombolysis were included in this study. Thrombus iodine concentrations (ICthrombus) and normalized iodine concentrations (NICthrombus) were compared to conventional perviousness parameters (thrombus attenuation increase, TAI; void fraction, ε and CTA-index). The associations between perviousness parameters and outcomes were analyzed by Spearman's correlation and regression analysis. RESULTS ICthrombus and NICthrombus were significantly correlated with conventional perviousness parameters (P < 0.001). The median ICthrombus was 6.81 (interquartile range [IQR], 4.76-8.73) mg/ml in the favorable functional outcome group, which was higher than 3.52 (IQR, 2.08-6.86) mg/ml in the unfavorable outcome group (P = 0.001). The median NICthrombus was 0.095 (IQR, 0.068-0.116) and 0.054 (IQR, 0.031-0.083) in the favorable and unfavorable outcome groups, respectively (P < 0.001). NICthrombus predicted favorable outcome with a higher area under the curve (AUC) of 0.755 than any conventional perviousness parameter (P < 0.05). In the multivariable regression model, ICthrombus was independently associated with favorable outcome (odds ratio [OR] = 1.472, 95 % CI: 1.154-1.877, P = 0.002) and successful recanalization (OR = 1.356, 95 % CI: 1.093-1.681, P = 0.006). ICthrombus was negatively correlated with the final infarct volume (FIV) (r = -0.262, P = 0.020). Results for NICthrombus were similar. CONCLUSIONS DECT is of great value in assessing thrombus perviousness. NICthrombus is a meaningful predictor of stroke prognosis and recanalization after intravenous thrombolysis in acute ischemic stroke.
Collapse
Affiliation(s)
- Yao Dai
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China; Department of Radiology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou 215124, China
| | - Haimin Xu
- Department of Radiology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou 215124, China
| | - Xiang Fang
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
| | - Xing Xiong
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
| | - Ziyang Song
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
| | - Su Hu
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
| | - Yixing Yu
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
| | - Chunhong Hu
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou 215006, China.
| | - Yu Zhang
- Department of Radiology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou 215124, China.
| |
Collapse
|
13
|
Ståhl F, Almqvist H, Kolloch J, Aspelin Å, Gontu V, Hummel E, van Vlimmeren M, Simon M, Thran A, Holmberg Å, Mazya MV, Söderman M, Delgado AF. Dual-Layer Detector Cone-Beam CT Angiography for Stroke Assessment: First-in-Human Results (the Next Generation X-ray Imaging System Trial). AJNR Am J Neuroradiol 2023; 44:523-529. [PMID: 37055159 PMCID: PMC10171384 DOI: 10.3174/ajnr.a7835] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 02/27/2023] [Indexed: 04/15/2023]
Abstract
BACKGROUND AND PURPOSE In patients with stroke, IV cone-beam CTA in the angiography suite could be an alternative to CTA to shorten the door-to-thrombectomy time. However, image quality in cone-beam CTA is typically limited by artifacts. This study evaluated a prototype dual-layer detector cone-beam CT angiography versus CTA in patients with stroke. MATERIALS AND METHODS A prospective, single-center trial enrolled consecutive patients with ischemic or hemorrhagic stroke on initial CT. Intracranial arterial segment vessel conspicuity and artifact presence were evaluated on dual-layer cone-beam CTA 70-keV virtual monoenergetic images and CTA. Eleven predetermined vessel segments were matched for every patient. Twelve patients were necessary to show noninferiority to CTA. Noninferiority was determined by the exact binomial test; the 1-sided lower performance boundary was prospectively set to 80% (98.75% CI). RESULTS Twenty-one patients had matched image sets (mean age, 72 years). After excluding examinations with movement or contrast media injection issues, all readers individually considered dual-layer cone-beam CT angiography noninferior to CTA (CI boundary, 93%, 84%, 80%, respectively) when evaluating arteries relevant in candidates for intracranial thrombectomy. Artifacts were more prevalent compared with CTA. The majority assessment rated each individual segment except M1 as having noninferior conspicuity compared with CTA. CONCLUSIONS In a single-center stroke setting, dual-layer detector cone-beam CTA virtual monoenergetic images are noninferior to CTA under certain conditions. Notably, the prototype is hampered by a long scan time and is not capable of contrast media bolus tracking. After excluding examinations with such scan issues, readers considered dual-layer detector cone-beam CTA noninferior to CTA, despite more artifacts.
Collapse
Affiliation(s)
- F Ståhl
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
- Department of Clinical Neuroscience (F.S., H.A., V.G., M.V.M., M. Söderman, A.F.D.) Karolinska Institutet, Stockholm, Sweden
| | - H Almqvist
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
- Department of Clinical Neuroscience (F.S., H.A., V.G., M.V.M., M. Söderman, A.F.D.) Karolinska Institutet, Stockholm, Sweden
| | - J Kolloch
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
| | - Å Aspelin
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
| | - V Gontu
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
- Department of Clinical Neuroscience (F.S., H.A., V.G., M.V.M., M. Söderman, A.F.D.) Karolinska Institutet, Stockholm, Sweden
| | - E Hummel
- Image Guided Therapy (E.H., M.v.V.), Phillips Healthcare, Best, the Netherlands
| | - M van Vlimmeren
- Image Guided Therapy (E.H., M.v.V.), Phillips Healthcare, Best, the Netherlands
| | - M Simon
- Philips Research Hamburg (M. Simon, A.T.), Hamburg, Germany
| | - A Thran
- Philips Research Hamburg (M. Simon, A.T.), Hamburg, Germany
| | - Å Holmberg
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
| | - M V Mazya
- Neurology (M.V.M.), Karolinska University Hospital, Stockholm, Sweden
- Department of Clinical Neuroscience (F.S., H.A., V.G., M.V.M., M. Söderman, A.F.D.) Karolinska Institutet, Stockholm, Sweden
| | - M Söderman
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
- Department of Clinical Neuroscience (F.S., H.A., V.G., M.V.M., M. Söderman, A.F.D.) Karolinska Institutet, Stockholm, Sweden
| | - A F Delgado
- From the Departments of Neuroradiology (F.S., H.A., J.K., Å.A., V.G., Å.H., M. Söderman, A.F.D.)
- Department of Clinical Neuroscience (F.S., H.A., V.G., M.V.M., M. Söderman, A.F.D.) Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
14
|
Estler A, Nikolaou K, Schönberg SO, Bamberg F, Froelich MF, Tollens F, Verloh N, Weiss J, Horger M, Hagen F. Is There Still a Role for Two-Phase Contrast-Enhanced CT and Virtual Monoenergetic Images in the Era of Photon-Counting Detector CT? Diagnostics (Basel) 2023; 13:diagnostics13081454. [PMID: 37189555 DOI: 10.3390/diagnostics13081454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 04/14/2023] [Accepted: 04/16/2023] [Indexed: 05/17/2023] Open
Abstract
BACKGROUND To compare the diagnostic characteristics between arterial phase imaging versus portal venous phase imaging, applying polychromatic T3D images and low keV virtual monochromatic images using a 1st generation photon-counting CT detector, of CT in patients with hepatocellular carcinoma (HCC). METHODS Consecutive patients with HCC, with a clinical indication for CT imaging, were prospectively enrolled. Virtual monoenergetic images (VMI) were reconstructed at 40 to 70 keV for the PCD-CT. Two independent, blinded radiologists counted all hepatic lesions and quantified their size. The lesion-to-background ratio was quantified for both phases. SNR and CNR were determined for T3D and low VMI images; non-parametric statistics were used. RESULTS Among 49 oncologic patients (mean age 66.9 ± 11.2 years, eight females), HCC was detected in both arterial and portal venous scans. The signal-to-noise ratio, the CNR liver-to-muscle, the CNR tumor-to-liver, and CNR tumor-to-muscle were 6.58 ± 2.86, 1.40 ± 0.42, 1.13 ± 0.49, and 1.53 ± 0.76 in the arterial phase and 5.93 ± 2.97, 1.73 ± 0.38, 0.79 ± 0.30, and 1.36 ± 0.60 in the portal venous phase with PCD-CT, respectively. There was no significant difference in SNR between the arterial and portal venous phases, including between "T3D" and low keV images (p > 0.05). CNRtumor-to-liver differed significantly between arterial and portal venous contrast phases (p < 0.005) for both "T3D" and all reconstructed keV levels. CNRliver-to-muscle and CNRtumor-to-muscle did not differ in either the arterial or portal venous contrast phases. CNRtumor-to-liver increased in the arterial contrast phase with lower keV in addition to SD. In the portal venous contrast phase, CNRtumor-to-liver decreased with lower keV; whereas, CNRtumor-to-muscle increased with lower keV in both arterial and portal venous contrast phases. CTDI and DLP mean values for the arterial upper abdomen phase were 9.03 ± 3.59 and 275 ± 133, respectively. CTDI and DLP mean values for the abdominal portal venous phase were 8.75 ± 2.99 and 448 ± 157 with PCD-CT, respectively. No statistically significant differences were found concerning the inter-reader agreement for any of the (calculated) keV levels in either the arterial or portal-venous contrast phases. CONCLUSIONS The arterial contrast phase imaging provides higher lesion-to-background ratios of HCC lesions using a PCD-CT; especially, at 40 keV. However, the difference was not subjectively perceived as significant.
Collapse
Affiliation(s)
- Arne Estler
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany
| | - Stefan O Schönberg
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, 79106 Freiburg, Germany
| | - Matthias F Froelich
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Fabian Tollens
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Niklas Verloh
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, 79106 Freiburg, Germany
| | - Jakob Weiss
- Department of Diagnostic and Interventional Radiology, Medical Center University of Freiburg, 79106 Freiburg, Germany
| | - Marius Horger
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany
| | - Florian Hagen
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany
| |
Collapse
|
15
|
Rotzinger DC, Qanadli SD, Fahrni G. Imaging the Vulnerable Carotid Plaque with CT: Caveats to Consider. Comment on Wang et al. Identification Markers of Carotid Vulnerable Plaques: An Update. Biomolecules 2022, 12, 1192. Biomolecules 2023; 13:biom13020397. [PMID: 36830766 PMCID: PMC9953174 DOI: 10.3390/biom13020397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/03/2023] [Accepted: 02/19/2023] [Indexed: 02/22/2023] Open
Abstract
We read with great interest the review by Wang et al. entitled "Identification Markers of Carotid Vulnerable Plaques: An Update", recently published in Biomolecules [...].
Collapse
Affiliation(s)
- David C. Rotzinger
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, 1015 Lausanne, Switzerland
- Correspondence: ; Tel.: +41-21-314-44-75
| | - Salah D. Qanadli
- Faculty of Biology and Medicine, University of Lausanne, 1015 Lausanne, Switzerland
- Riviera-Chablais Hospital, 1847 Rennaz, Switzerland
| | - Guillaume Fahrni
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011 Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, 1015 Lausanne, Switzerland
| |
Collapse
|
16
|
D’Angelo T, Vizzari G, Lanzafame LRM, Pergolizzi F, Mazziotti S, Gaeta M, Costa F, Di Bella G, Vogl TJ, Booz C, Micari A, Blandino A. Spectral CT Imaging of Prosthetic Valve Embolization after Transcatheter Aortic Valve Implantation. Diagnostics (Basel) 2023; 13:678. [PMID: 36832165 PMCID: PMC9955456 DOI: 10.3390/diagnostics13040678] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/06/2023] [Accepted: 02/08/2023] [Indexed: 02/15/2023] Open
Abstract
Transcatheter heart valve (THV) embolization is a rare complication of transcatheter aortic valve implantation (TAVI) generally caused by malpositioning, sizing inaccuracies and pacing failures. The consequences are related to the site of embolization, ranging from a silent clinical picture when the device is stably anchored in the descending aorta to potentially fatal outcomes (e.g., obstruction of flow to vital organs, aortic dissection, thrombosis, etc.). Here, we present the case of a 65-year-old severely obese woman affected by severe aortic valve stenosis who underwent TAVI complicated by embolization of the device. The patient underwent spectral CT angiography that allowed for improved image quality by means of virtual monoenergetic reconstructions, permitting optimal pre-procedural planning. She was successfully re-treated with implantation of a second prosthetic valve a few weeks later.
Collapse
Affiliation(s)
- Tommaso D’Angelo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
- Department of Radiology and Nuclear Medicine, Erasmus MC, 3015 GD Rotterdam, The Netherlands
| | - Giampiero Vizzari
- Cardiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Ludovica R. M. Lanzafame
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Federica Pergolizzi
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Silvio Mazziotti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Michele Gaeta
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Francesco Costa
- Cardiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Gianluca Di Bella
- Cardiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Thomas J. Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany
| | - Antonio Micari
- Cardiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| | - Alfredo Blandino
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy
| |
Collapse
|
17
|
Rippel K, Decker JA, Wudy R, Trzaska T, Haerting M, Kroencke TJ, Schwarz F, Scheurig-Muenkler C. Evaluation of run-off computed tomography angiography on a first-generation photon-counting detector CT scanner - Comparison with low-kVp energy-integrating CT. Eur J Radiol 2023; 158:110645. [PMID: 36525704 DOI: 10.1016/j.ejrad.2022.110645] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/23/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022]
Abstract
PURPOSE To assess the overall imaging performance (radiation dose and image quality) of a photon-counting detector CT (PCD-CT) in comparison with a state-of-the-art energy-integrating detector CT (EID-CT) in run-off CTAs. METHODS Consecutive patients who underwent run-off CTA on a PCD-CT were included (PCD-CT cohort). A retrospective cohort of patients who had undergone run-off CTA on an EID-CT was matched for gender, body mass index, height, and age (EID-CT cohort). Virtual monoenergetic imaging (VMI) reconstructions for various keV settings (40-120 keV) were generated. CT values and noise were semiautomatically measured for 13 vascular segments of the abdomen, pelvis, and lower extremities. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for each segment. Subjective image quality was evaluated by two radiologists along the dimensions 'vessel attenuation', 'vessel sharpness', and 'overall image quality' using 5-point Likert scales. RESULTS Forty patients (age 70.9 ± 9.8 years; 14 women) were included in the PCD-CT cohort and matched with a corresponding number of EID-CT patients. Overall, there was an inverse correlation of signal and noise but also of SNR and CNR with keV levels used for VMI reconstructions. SNR and CNR in the 40 - 60 keV range exceeded EID-CT levels significantly. Subjective image quality was substantially higher at lower keV levels and showed no significant difference to EID-CT. CONCLUSION Low keV VMI reconstructions of run-off CTA scans on a PCD-CT result in substantially higher SNR and CNR than 80 kVp and 100 kVp EID-CT acquisitions with equal subjective image quality.
Collapse
Affiliation(s)
- K Rippel
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
| | - J A Decker
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
| | - R Wudy
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
| | - T Trzaska
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
| | - M Haerting
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
| | - T J Kroencke
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany; Centre for Advanced Analytics and Predictive Sciences (CAAPS), University of Augsburg, Universitätsstr. 2, 86159 Augsburg, Germany.
| | - F Schwarz
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany; Medical Faculty, Ludwig Maximilian University Munich, Bavariaring 19, 80336 Munich, Germany.
| | - C Scheurig-Muenkler
- Diagnostic and Interventional Radiology, University Hospital Augsburg, Faculty of Medicine, University of Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
| |
Collapse
|
18
|
Multi-Energy CT Applications. Radiol Clin North Am 2023; 61:1-21. [DOI: 10.1016/j.rcl.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
19
|
Seo JY, Joo I, Yoon JH, Kang HJ, Kim S, Kim JH, Ahn C, Lee JM. Deep learning-based reconstruction of virtual monoenergetic images of kVp-switching dual energy CT for evaluation of hypervascular liver lesions: Comparison with standard reconstruction technique. Eur J Radiol 2022; 154:110390. [PMID: 35724579 DOI: 10.1016/j.ejrad.2022.110390] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 01/12/2022] [Accepted: 05/31/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate clinical applicability of deep learning(DL)-based reconstruction of virtual monoenergetic images(VMIs) of arterial phase liver CT obtained by rapid kVp-switching dual-energy CT for evaluation of hypervascular liver lesions. MATERIALS AND METHODS We retrospectively included 109 patients who had available late arterial phase liver CT images of the liver obtained with a rapid switching kVp DECT scanner for suspicious intra-abdominal malignancies. Two VMIs of 70 keV and 40 keV were reconstructed using adaptive statistical iterative reconstruction (ASiR-V) for arterial phase scans. VMIs at 40 keV were additionally reconstructed with a vendor-agnostic DL-based reconstruction technique (ClariCT.AI, ClariPi, DL 40 keV). Qualitative, quantitative image quality and subjective diagnostic acceptability were compared according to reconstruction techniques. RESULTS In qualitative analysis, DL 40 keV images showed less image noise (4.55 vs 3.11 vs 3.95, p < 0.001), better image sharpness (4.75 vs 4.16 vs 4.3, p < 0.001), better image contrast (4.98 vs 4.72 vs 4.19, p < 0.017), better lesion conspicuity (4.61 vs 4.23 vs 3.4, p < 0.001) and diagnostic acceptability (4.59 vs 3.88 vs 4.09, p < 0.001) compared with ASiR-V 40 keV or 70 keV image sets. In quantitative analysis, DL 40 keV significantly reduced image noise relative to ASiR-V 40 keV images (49.9%, p < 0.001) and ASiR-V 70 keV images (85.2%, p = 0.012). DL 40 keV images showed significantly higher CNRlesion to the liver and SNRliver than ASiR-V 40 keV image and 70 keV images (p < 0.001). CONCLUSION DL-based reconstruction of 40 keV images using vendor-agnostic software showed greater noise reduction, better lesion conspicuity, image contrast, image sharpness, and higher overall image diagnostic acceptability than ASiR for 40 keV or 70 keV images in patients with hypervascular liver lesions.
Collapse
Affiliation(s)
- June Young Seo
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Hyo Jin Kang
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Sewoo Kim
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jong Hyo Kim
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea; Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea; Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea; Research Institute, ClariPi, Seoul, Republic of Korea
| | - Chulkyun Ahn
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea; Research Institute, ClariPi, Seoul, Republic of Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
20
|
Michael AE, Boriesosdick J, Schoenbeck D, Lopez-Schmidt I, Kroeger JR, Moenninghoff C, Horstmeier S, Pennig L, Borggrefe J, Niehoff JH. Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions. Diagnostics (Basel) 2022; 12:diagnostics12061306. [PMID: 35741116 PMCID: PMC9222087 DOI: 10.3390/diagnostics12061306] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/21/2022] [Accepted: 05/22/2022] [Indexed: 11/16/2022] Open
Abstract
Background: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. Methods: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40–120 keV). Additionally, two radiologists rated the perceived image quality. Results: The mean CTDIvol used in the PCCT was 8.31 ± 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60–65 keV was rated as best image quality. Conclusion: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.
Collapse
Affiliation(s)
- Arwed Elias Michael
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
- Correspondence: ; Tel.: +49-571-790-4601
| | - Jan Boriesosdick
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Denise Schoenbeck
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Ingo Lopez-Schmidt
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Jan Robert Kroeger
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Christoph Moenninghoff
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Sebastian Horstmeier
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Lenhard Pennig
- Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50923 Cologne, Germany;
| | - Jan Borggrefe
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| | - Julius Henning Niehoff
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 32429 Minden, Germany; (J.B.); (D.S.); (I.L.-S.); (J.R.K.); (C.M.); (S.H.); (J.B.); (J.H.N.)
| |
Collapse
|
21
|
Initial Investigation of Clinical Value of Noise-Optimized Virtual Monoenergetic Images Derived From Dual-Energy Computed Tomography Angiography in Preoperative Perforator Planning of Anterolateral Thigh Flap Transplantation. J Comput Assist Tomogr 2022; 46:560-567. [PMID: 35405721 DOI: 10.1097/rct.0000000000001320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To objectively and subjectively assess the image characteristics of noise-optimized virtual monoenergetic images [MEI (+)] and polyenergetic images (PEIs) from dual-energy computed tomography angiography and then to explore the clinical value of the optimal MEI (+) in preoperative perforator planning of anterolateral thigh (ALT) flap transplantation. METHODS Sixteen patients (32 thighs) who underwent lower extremity run-off dual-energy computed tomography angiography for planning ALT flap transplantation were enrolled. One standard PEI and 5 MEI (+) in 10-keV intervals (range, 40-80 keV) were reconstructed. First, we compared the image quality subjectively (branch order, image quality, and vascular network continuity) and objectively (vascular attenuation, image noise, signal-to-noise ratio, and the contrast-to-noise ratio). Then, we compared the clinical value (number, type, source artery, pedicle length, caliber, and location of all sizable perforators) between the optimal MEI (+) and PEI groups. RESULTS The 40-keV MEI (+) was rated superior subjective and objective image quality metrics to PEI (all P < 0.001). Compared with PEI, 40 keV MEI (+) increased the number of visible perforators, the percentage of perforators with identifiable types, and the measurable length of perforator pedicle (all P < 0.001). CONCLUSIONS We recommend 40 keV MEI (+) for the visualization of perforators and their contribution to the selection and location of suitable perforators in preoperative planning for ALT flaps.
Collapse
|
22
|
Euler A, Higashigaito K, Mergen V, Sartoretti T, Zanini B, Schmidt B, Flohr TG, Ulzheimer S, Eberhard M, Alkadhi H. High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose. Invest Radiol 2022; 57:115-121. [PMID: 34352805 DOI: 10.1097/rli.0000000000000816] [Citation(s) in RCA: 105] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The aims of this study were to determine the objective and subjective image quality of high-pitch computed tomography (CT) angiography of the aorta in clinical dual-source photon-counting detector CT (PCD-CT) and to compare the image quality to conventional dual-source energy-integrating detector CT (EID-CT) in the same patients at equal radiation dose. MATERIALS AND METHODS Patients with prior CT angiography of the thoracoabdominal aorta acquired on third-generation dual-source EID-CT in the high-pitch mode and with automatic tube voltage selection (ATVS, reference tube voltage 100 kV) were included. Follow-up imaging was performed on a first-generation, clinical dual-source PCD-CT scanner in the high-pitch and multienergy (QuantumPlus) mode at 120 kV using the same contrast media protocol as with EID-CT. Radiation doses between scans were matched by adapting the tube current of PCD-CT. Polychromatic images for both EID-CT and PCD-CT (called T3D) and virtual monoenergetic images at 40, 45, 50, and 55 keV for PCD-CT were reconstructed. Computed tomography attenuation was measured in the aorta; noise was defined as the standard deviation of attenuation; contrast-to-noise ratio (CNR) was calculated. Subjective image quality (noise, vessel attenuation, vessel sharpness, and overall quality) was rated by 2 blinded, independent radiologists. RESULTS Forty patients were included (mean age, 63 years; 8 women; mean body mass index [BMI], 26 kg/m2). There was no significant difference in BMI, effective diameter, or radiation dose between scans (all P's > 0.05). The ATVS in EID-CT selected 70, 80, 90, 100, 110, and 120 kV in 2, 14, 14, 7, 2, and 1 patients, respectively. Mean CNR was 17 ± 8 for EID-CT and 22 ± 7, 20 ± 6, 18 ± 5, 16 ± 5, and 12 ± 4 for PCD-CT at 40, 45, 50, 55 keV, and T3D, respectively. Contrast-to-noise ratio was significantly higher for 40 and 45 keV of PCD-CT as compared with EID-CT (both P's < 0.05). The linear regression model (adjusted R2, 0.38; P < 0.001) revealed that PCD-CT reconstruction (P < 0.001), BMI group (P = 0.007), and kV of the EID-CT scan (P = 0.01) were significantly associated with CNR difference, with an increase by 34% with PCD-CT for overweight as compared with normal weight patients. Subjective image quality reading revealed slight differences between readers for subjective vessel attenuation and sharpness, whereas subjective noise was rated significantly higher for 40 and 45 keV (P < 0.001) and overall quality similar (P > 0.05) between scans. CONCLUSIONS High-pitch PCD-CT angiography of the aorta with VMI at 40 and 45 keV resulted in significantly increased CNR compared with EID-CT with ATVS at matched radiation dose. The CNR gain of PCD-CT increased in overweight patients. Taking into account the subjective analysis, VMI at 45 to 50 keV is proposed as the best trade-off between objective and subjective image quality.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Kai Higashigaito
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Victor Mergen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | | | - Bettina Zanini
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
23
|
Chen J, Niu Z, Zhan K, Tao X, Tian F, Ding J, Jin Z, Hu X. Evaluation of Modified Calcium Removal Algorithm in dual energy CT of Internal Carotid Artery. Eur J Radiol 2021; 145:109927. [PMID: 34773829 DOI: 10.1016/j.ejrad.2021.109927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 06/23/2021] [Accepted: 08/14/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the performance of a dual-energy (DE) calcium removal software based on a modified three-material decomposition algorithm in assessing the stenosis of the internal carotid artery (ICA) in comparison with mixed images using digital subtraction angiography (DSA) as the reference standard. METHODS Forty-six patients (38 men; 67±8 years old), including 154 calcified ICA segments C1-C2 (59), C3-C5 (63), C6 (24), and C7 (8), were recruited in this retrospective study. Mixed images and virtual non-calcium (VNCa) images using the modified dual-energy computed tomography (DECT) algorithm were reconstructed. The differences between VNCa and DSA images vs. mixed and DSA images of degree of stenosis were compared. The intraclass correlation coefficient (ICC) was used for assessing the agreement between VNCa, mixed images, and DSA. RESULTS The degree of stenosis differed significantly between mixed and DSA images in the C3-C5 (30%±17.9% vs. 23.0%±16.9%, p = 0.026) and C6 (38.3%±15.4% vs. 28.5%±13.3%, p = 0.023) segments. The stenosis of VNCa images showed no significant difference with DSA images in all segments (all p > 0.05). The ICCs between VNCa and DSA images (0.86-0.97) were higher than those between the mixed and DSA images (0.68-0.96) in all segments. CONCLUSION The performance of a modified three-material decomposition DECT algorithm for calcium removal in ICA stenosis evaluation, particularly for the C3-C5 and C6 ICA segments, was promising.
Collapse
Affiliation(s)
- Jiao Chen
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China
| | - Zhongfeng Niu
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China
| | - Kun Zhan
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China
| | - Xinwei Tao
- Siemens Healthineers China, No.399, West Haiyang Road, Shanghai, China
| | - Fengjuan Tian
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China
| | - Jing Ding
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China
| | - Zhexia Jin
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China
| | - Xiuhua Hu
- Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou City 310016, Zhejiang Province, China.
| |
Collapse
|
24
|
Li J, Wang YH, Zheng FL, Chen XY, Lin Y, Zhu CR, Wu YF, Xu Q, Jin ZY, Xue HD. Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study. Insights Imaging 2021; 12:166. [PMID: 34767101 PMCID: PMC8589906 DOI: 10.1186/s13244-021-01079-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 07/18/2021] [Indexed: 11/10/2022] Open
Abstract
Objectives The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging (VMI+) and high-concentration (400 mgI/mL) CM.
Materials and methods 41 patients who underwent both normal dose CM (ND-CM, 320 mgI/kg) and low dose CM (LD-CM, 224 mgI/kg) thoracoabdominal enhanced CT for tumor follow-up were prospectively included. The VMI+ at the energy level of 40-kev for LD-CM images was reconstructed. CT attenuation, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the abdominal artery, celiac artery, and superior mesenteric artery (SMA) and qualitative scores of pancreatic arteries depiction were recorded and compared among the three groups (ND-CM, LD-CM, and VMI+ LD-CM images). ANOVA and Friedman tests were used for statistical analysis. Results All quantitative and qualitative parameters on LD-CM images were lower than that on ND-CM images (all p < 0.01). There were no significant differences of all arteries’ qualitative scores between ND-CM and VMI+ LD-CM images (all p > 0.05). VMI+ LD-CM images had the highest mean CT and CNR values of all arteries (all p < 0.0001). The CM volume was 52.6 ± 9.4 mL for the ND-CM group and 37.0 ± 6.7 mL for the LD-CM group. Conclusion Ultra-low-dose CM (224 mgI/kg) was feasible for depicting pancreatic arteries. Inferior angiographic image quality could be successfully compensated by VMI+ and high-concentration CM.
Collapse
Affiliation(s)
- Juan Li
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Yu-Hong Wang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Fu-Ling Zheng
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | | | - Yun Lin
- Global Medical and Regulatory Affairs, Bracco Imaging Medical Technologies Co., Ltd, Shanghai, China
| | - Cai-Rong Zhu
- Department of Epidemiology and Health Statistics, West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China
| | - Yi-Fan Wu
- Global Medical and Regulatory Affairs, Bracco Imaging Medical Technologies Co., Ltd, Shanghai, China
| | - Qiang Xu
- Department of General Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Zheng-Yu Jin
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China.
| | - Hua-Dan Xue
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China.
| |
Collapse
|
25
|
Zeng Y, Geng D, Zhang J. Noise-optimized virtual monoenergetic imaging technology of the third-generation dual-source computed tomography and its clinical applications. Quant Imaging Med Surg 2021; 11:4627-4643. [PMID: 34737929 DOI: 10.21037/qims-20-1196] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 06/02/2021] [Indexed: 02/05/2023]
Abstract
The third-generation dual-source computed tomography (DSCT) is among the most advanced imaging methods. It employs noise-optimized virtual monoenergetic imaging (VMI+) technology. It uses the frequency-split method to extract high-contrast image information from low-energy images and low-noise information from images reconstructed at an optimal energy level, combining them to obtain the final image with improved quality. This review is the first to summarize the results of clinical studies that primarily and recently evaluated the VMI+ technique based on tumor, blood vessel, and other lesion classification. We aim to assist radiologists in quickly selecting the appropriate energy level when performing image reconstruction for superior image quality in clinical work and providing several ideas for future scientific research of the VMI+ technique. Presently, VMI+ reconstruction is mostly used for images of various tumors or blood vessels, including coronary plaques, coronary stents, deep vein thromboses, pulmonary embolisms (PEs), active arterial hemorrhages, and endoleaks after endovascular aneurysm repair. In addition, VMI+ has been used for imaging children's heads, liver lesions, pancreatic lacerations, and reducing metal artifacts. Regarding the reconstruction at the optimal energy level, the VMI+ technique yielded a higher image quality than the pre-optimized virtual monoenergetic imaging (VMI) technique and single-energy CT. Moreover, either low concentrations of contrast medium or low iodine injection rates can be applied before VMI+ reconstruction at a low-energy level to reduce contrast agent-related kidney injury risk. After reconstructing an image at the optimal energy level, both the image's window width and level can also be adjusted to improve the image effect's reach and diagnosis suitability. To improve image quality and lesion-imaging clarity and reduce the use of contrast agents, VMI+ reconstruction technology has been applied clinically, in which the selection of energy level is the key to the whole reconstruction process. Our review summarizes these optimal levels for radiologists' reference and suggests new ideas for the direction of future VMI+ research.
Collapse
Affiliation(s)
- Yanwei Zeng
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| | - Daoying Geng
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| | - Jun Zhang
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| |
Collapse
|
26
|
Soumah M, Brami J, Simonato D, Chousterman B, Guillonnet A, Bernat AL, Houdart E, Labeyrie MA. Computed tomography angiography for quantification of cerebral vasospasm following aneurysmal subarachnoid hemorrhage. Diagn Interv Imaging 2021; 103:161-169. [PMID: 34742674 DOI: 10.1016/j.diii.2021.10.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 10/09/2021] [Accepted: 10/12/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE The purpose of this study was to assess the accuracy of computed tomography angiography (CTA) for quantification of cerebral vasospasm following aneurysmal subarachnoid hemorrhage in proximal and middle segments of intracranial arteries. MATERIALS AND METHODS Twenty consecutive patients (7 men, 13 women; mean age, 47 ± 7 [SD] years; age range: 27-78 years) with aneurysmal subarachnoid hemorrhage who underwent CTA and digital subtracted angiography (DSA) with a 6-hour window at baseline and during vasospasm period were included. Twelve artery segments were analyzed in each patient. Vasospasm was blindly quantified on CTA and digital subtracted angiography (DSA) by two independent readers with discordance > 10% resolved by open data consensus. Inter-reader and inter-test correlations with DSA as reference, and causes of discordant readings were analyzed. The best sensitivity and specificity of CTA for determination of vasospasm ≥ 50% on DSA was determined using receiver operating curve analysis. RESULTS Two-hundred-and-ten arterial segments were analyzed after exclusion of 30 segments with missing data or metallic artifacts. An inter-reader discordance >10% was observed in 82 segments (82/210; 39% [95% CI: 32-46]). Inter-test discordances >10% were observed respectively in 115 segments (115/210; 55% [95% CI: 49-62]) with the junior reader and in 73 segments (73/210; 35% [95% CI: 29-42]) with the senior reader. They were related to reader error in 55 (55/210; 26% [95% CI: 20-32]) with the junior reader and 13 (13/210; 6% [95% CI: 3-9]) with the senior reader, as well systematic biases in 8 (8/210; 4% [95% CI: 1-6]), and intrinsic limitation in 52 (52/210; 25% [95% CI: 19-31]). Best sensitivity and specificity of CTA were observed for a threshold value of 30% (sensitivity = 88% [95% CI: 78-97%]; specificity = 84% [95% CI: 77-90%]; area under curve = 0.92 [95% CI: 0.86-0.97]). On a patient basis, sensitivity was 100% (specificity = 60% [95% CI: 38-81%]; area under curve = 0.97 [95% CI: 89-100%] for this same threshold. CONCLUSION Our study shows a moderate accuracy of CTA for the quantification of cerebral vasospasm, mostly related to challenging interpretation and intrinsic limitations. CTA may rule-out angiographic vasospasm ≥ 50% when no segment has vasospasm over than 30%.
Collapse
Affiliation(s)
- Mariam Soumah
- Department of Neuroradiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France; Faculté de Médecine, Université de Paris, Paris 75010, France
| | - Jonathan Brami
- Department of Neuroradiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France; Faculté de Médecine, Université de Paris, Paris 75010, France
| | - Davide Simonato
- Department of Neuroradiology, John Radcliffe Hospital, Oxford National Health Care, Oxford University, Oxford OX3 9DU, UK
| | - Benjamin Chousterman
- Faculté de Médecine, Université de Paris, Paris 75010, France; Intensive Care Unit, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France
| | - Antoine Guillonnet
- Department of Neuroradiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France; Faculté de Médecine, Université de Paris, Paris 75010, France
| | - Anne-Laure Bernat
- Faculté de Médecine, Université de Paris, Paris 75010, France; Department of Neurosurgery, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France
| | - Emmanuel Houdart
- Department of Neuroradiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France; Faculté de Médecine, Université de Paris, Paris 75010, France
| | - Marc-Antoine Labeyrie
- Department of Neuroradiology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris 75010, France; Faculté de Médecine, Université de Paris, Paris 75010, France.
| |
Collapse
|
27
|
D'Angelo T, Albrecht MH, Caudo D, Mazziotti S, Vogl TJ, Wichmann JL, Martin S, Yel I, Ascenti G, Koch V, Cicero G, Blandino A, Booz C. Virtual non-calcium dual-energy CT: clinical applications. Eur Radiol Exp 2021; 5:38. [PMID: 34476640 PMCID: PMC8413416 DOI: 10.1186/s41747-021-00228-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 06/11/2021] [Indexed: 12/15/2022] Open
Abstract
Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of different body areas. The virtual non-calcium (VNCa) reconstruction algorithm has shown beneficial effects on the depiction of bone marrow pathologies such as bone marrow edema. Its main advantage is the ability to substantially increase the image contrast of structures that are usually covered with calcium mineral, such as calcified vessels or bone marrow, and to depict a large number of traumatic, inflammatory, infiltrative, and degenerative disorders affecting either the spine or the appendicular skeleton. Therefore, VNCa imaging represents another step forward for DECT to image conditions and disorders that usually require the use of more expensive and time-consuming techniques such as magnetic resonance imaging, positron emission tomography/CT, or bone scintigraphy. The aim of this review article is to explain the technical background of VNCa imaging, showcase its applicability in the different body regions, and provide an updated outlook on the clinical impact of this technique, which goes beyond the sole improvement in image quality.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Moritz H Albrecht
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
| | - Danilo Caudo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Silvio Mazziotti
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Thomas J Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Julian L Wichmann
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Simon Martin
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Ibrahim Yel
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Giorgio Ascenti
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Vitali Koch
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Giuseppe Cicero
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Alfredo Blandino
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| |
Collapse
|
28
|
Zopfs D, Lennartz S, Abdullayev N, Lichtenstein T, Laukamp KR, Reimer RP, Kabbasch C, Borggrefe J, Schlamann M, Neuhaus V, Große Hokamp N. Generally applicable window settings of low-keV virtual monoenergetic reconstructions in dual-layer CT-angiography of the head and neck. Quant Imaging Med Surg 2021; 11:3408-3417. [PMID: 34341719 DOI: 10.21037/qims-20-1140] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 03/25/2021] [Indexed: 11/06/2022]
Abstract
Background Increased vessel contrast in low-keV virtual monoenergetic images (VMI) in spectral detector CT angiography of the head and neck requires adaption of window settings. Aim of this study was to define generally applicable window settings of low-keV VMI. Methods Two radiologists determined ideal subjective window settings for VMI40-70 keV in 54 patients. To obtain generally applicable window settings, center and width values were modeled against the attenuation of the internal carotid artery (HUICA). This modeling was performed with and without respect to keV. Subsequently, image quality of VMI40-70 keV was assessed using the model-based determined window settings. Results With decreasing keV values, HUICA increased significantly in comparison to conventional images (CI) (P<0.05 for 40-60 keV). No significant differences between modelled and individually recorded window settings were found confirming validity of the obtained models (P values: 0.2-1.0). However, modelling with respect to keV was marginally less precise. Conclusions Window settings of low-keV VMI can be semi-automatically determined in dependency of the ICA attenuation in spectral detector CTA of the head and neck. The reported models are a promising tool to leverage the improved image quality of these images in clinical routine.
Collapse
Affiliation(s)
- David Zopfs
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Simon Lennartz
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany.,Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Nuran Abdullayev
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Thorsten Lichtenstein
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Kai Roman Laukamp
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Robert Peter Reimer
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Christoph Kabbasch
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Jan Borggrefe
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Marc Schlamann
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Victor Neuhaus
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| | - Nils Große Hokamp
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University Cologne, Cologne, Germany
| |
Collapse
|
29
|
Effect of energy level on the spatial resolution and noise frequency characteristics of virtual monochromatic images: a phantom experiment using four types of CT scanners. Jpn J Radiol 2021; 40:94-102. [PMID: 34304382 DOI: 10.1007/s11604-021-01180-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Accepted: 07/19/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The purpose of the study is to evaluate the effect of energy level on the modulation transfer functions (MTF) and noise power spectra (NPS) of virtual monochromatic images (VMIs) obtained using four types of computed-tomographic (CT) scanners: Revolution, SOMATOM, IQon, and Aquilion. MATERIALS AND METHODS VMIs were obtained at 70, 60, and 50 kiloelectron volts (keV), and also at the lowest keV available in each scanner. We evaluated the MTF and NPS in the VMIs obtained at each keV. RESULTS No significant effect of the energy level on the MTF was observed in IQon, whereas the spatial resolution decreased as the energy level decreased in the other types of scanners. The NPS curves tended to increase as the energy levels decreased with three types of scanners other than Aquilion. CONCLUSION The spatial resolution and noise frequency characteristics of VMIs may be affected by the energy level, and the effects of energy level on these characteristics differ depending on the type of CT scanners.
Collapse
|
30
|
Fernandez-Velilla Cepria E, González-Ballester MÁ, Quera Jordana J, Pera O, Sanz Latiesas X, Foro Arnalot P, Membrive Conejo I, Rodriguez de Dios N, Reig Castillejo A, Algara Lopez M. Determination of the optimal range for virtual monoenergetic images in dual-energy CT based on physical quality parameters. Med Phys 2021; 48:5085-5095. [PMID: 34287956 DOI: 10.1002/mp.15120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/29/2021] [Accepted: 07/12/2021] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Virtual monoenergetic images (VMI) obtained from Dual-Energy Computed Tomography (DECT) with iodinated contrast are used in radiotherapy of the Head and Neck to improve the delineation of target volumes and organs at-risk (OAR). The energies used to vary from 40 to 70 keV, but noise at low keV and the use of Single Energy CT (SECT) at low kVp settings may shrink this interval. There is no guide about how to find out the optimal range where VMI has a significant improvement related to SECT images. Our study proposes a procedure to determine this optimal range, based on common image quality parameters, and establishes this range in a Siemens Somatom Confidence and a Head and Neck protocol. METHODS We compared the quality of the VMI series at 40-60 keV versus single X-ray tube voltage computed tomography (SECT) at 80 and 120 kVp . Our reference was 120 kVp . DECT images were sequentially acquired using the Siemens Somatom Confidence RT Pro CT according to the head and neck protocol in our department. VMI series were constructed using the Syngo Via software Monoenergetic+ algorithm. Quality parameters were: image uniformity, high- and low-contrast resolution, noise, and sensitivity to the iodinated contrast. We used the Catphan 604 phantom for quality control, except when assessing iodine sensitivity. To evaluate high contrast resolution, we calculated the modulation transfer function (MTF) using the point spread function estimation of a point bead and the slanted edge methods. For the low-contrast resolution, we used a statistical method for assessing differences between contrast structures and local noise. To measure the absolute value of noise and compare its texture, we used the standard deviation and the noise power spectrum. We measured iodine sensitivity by dissolving the Optiray Ultraject iodinated contrast in water in concentrations of 0 to 4500 mg/l and then compared the contrast to noise ratio (CNR) and analyzed the linear correlation between concentration and HU. RESULTS The entire series met the minimum quality requirements. However, the one at 40 keV presented uniformity at the limits of acceptability. The high- and low-contrast resolutions were similar between series. The noise of the VMI series decreased with increasing energy, while sensitivity to the contrast displayed the opposite behavior. All series showed linearity of HUs from very low iodine concentrations. Images at 60 keV presented lower iodine sensitivity than SECT at 80 kVp , while those at 55 keV were similar to them. CONCLUSIONS Our method of image comparison based on standard quality parameters in phantom gave clear results about the optimal range and can be used as a guide to characterize any other DECT imaging protocols. The optimal range for using VMI images in iodinated contrasts in the Siemens system was 45-55 keV. Lower energies lacked noise and uniformity, while higher ones could be substituted by SECT images at low kilovoltage (80 kVp ).
Collapse
Affiliation(s)
- Enric Fernandez-Velilla Cepria
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain
| | - Miguel Ángel González-Ballester
- Department of Information and Communication Technologies, BCN Medtech, Universitat Pompeu Fabra, Barcelona, Spain.,ICREA, Barcelona, Spain
| | - Jaume Quera Jordana
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain.,Universitat Pompeu Fabra, Barcelona, Spain
| | - Oscar Pera
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain
| | - Xavier Sanz Latiesas
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain.,Universitat Pompeu Fabra, Barcelona, Spain
| | - Palmira Foro Arnalot
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain.,Universitat Pompeu Fabra, Barcelona, Spain
| | - Ismael Membrive Conejo
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain
| | - Nuria Rodriguez de Dios
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain.,Universitat Pompeu Fabra, Barcelona, Spain
| | - Anna Reig Castillejo
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain
| | - Manuel Algara Lopez
- Radiation Oncology Department, Hospital del Mar, Barcelona, Spain.,IMIM (Hospital del Mar Medical Research Institute), Barcelona, Spain.,Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
31
|
Lenga L, Lange M, Martin SS, Albrecht MH, Booz C, Yel I, Arendt CT, Vogl TJ, Leithner D. Head and neck single- and dual-energy CT: differences in radiation dose and image quality of 2nd and 3rd generation dual-source CT. Br J Radiol 2021; 94:20210069. [PMID: 33914613 PMCID: PMC8173672 DOI: 10.1259/bjr.20210069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 02/16/2021] [Accepted: 02/22/2021] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVES To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts. METHODS 200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups (n = 50) matched by gender and BMI: second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assessment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measurements and dose-independent figure-of-merit calculations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evaluated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales. RESULTS Effective radiation dose (ED) was not significantly different between SECT and DECT acquisition for each scanner generation (p = 0.10). Significantly lower effective radiation dose (p < 0.01) values were observed for third-generation DSCT groups C (1.1 ± 0.2 mSv) and D (1.0 ± 0.3 mSv) compared to second-generation DSCT groups A (1.8 ± 0.1 mSv) and B (1.6 ± 0.2 mSv). Figure-of-merit/contrast-to-noise ratio analysis revealed superior results for third-generation DECT Group D compared to all other groups. Qualitative image parameters showed non-significant differences between all groups (p > 0.06). CONCLUSION Contrast-enhanced head and neck DECT can be performed with second- and third-generation DSCT systems without radiation penalty or impaired image quality compared with SECT, while third-generation DSCT is the most dose efficient acquisition method. ADVANCES IN KNOWLEDGE Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.
Collapse
Affiliation(s)
- Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Marvin Lange
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Simon S Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Christophe T Arendt
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | | |
Collapse
|
32
|
Lim HJ, Hwang JH, Kim JH, Park S, Lee KH, Park SH. Fistula from right and left coronary arteries to pulmonary artery: Coronary CT angiography and coronary angiography findings. Radiol Case Rep 2021; 16:1790-1793. [PMID: 34025888 PMCID: PMC8121624 DOI: 10.1016/j.radcr.2021.04.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 04/03/2021] [Accepted: 04/06/2021] [Indexed: 11/19/2022] Open
Abstract
Coronary artery fistula is an abnormal communication between the coronary artery and either the cardiac chamber or the great vessel. In particular, the coronary-to-pulmonary artery fistula can be supplied by either one or both coronary arteries and drains to the pulmonary trunk. We report a unique case of fistula originating from both coronary arteries and draining into both sinuses of the main pulmonary artery in a 57-year-old female who experienced chronic chest pain and palpitation. Dilated and tortuous fistulas were found in coronary angiography and coronary computed tomography angiography examinations. To aid early diagnosis and clinical management, radiologists should be aware of the characteristic radiologic findings.
Collapse
|
33
|
Hamid S, Nasir MU, So A, Andrews G, Nicolaou S, Qamar SR. Clinical Applications of Dual-Energy CT. Korean J Radiol 2021; 22:970-982. [PMID: 33856133 PMCID: PMC8154785 DOI: 10.3348/kjr.2020.0996] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/16/2020] [Accepted: 11/22/2020] [Indexed: 01/05/2023] Open
Abstract
Dual-energy CT (DECT) provides insights into the material properties of tissues and can differentiate between tissues with similar attenuation on conventional single-energy imaging. In the conventional CT scanner, differences in the X-ray attenuation between adjacent structures are dependent on the atomic number of the materials involved, whereas in DECT, the difference in the attenuation is dependent on both the atomic number and electron density. The basic principle of DECT is to obtain two datasets with different X-ray energy levels from the same anatomic region and material decomposition based on attenuation differences at different energy levels. In this article, we discuss the clinical applications of DECT and its potential robust improvements in performance and postprocessing capabilities.
Collapse
Affiliation(s)
- Saira Hamid
- Department of Radiology, University of British Columbia Hospital, University of British Columbia, Vancouver, Canada.
| | - Muhammad Umer Nasir
- Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Aaron So
- Department of Medical Biophyics, Schulich School of Medicine and Dentistry Western University London, Ontario, Canada
| | - Gordon Andrews
- Department of Radiology, University of British Columbia Hospital, University of British Columbia, Vancouver, Canada
| | - Savvas Nicolaou
- Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, Vancouver, Canada
| | - Sadia Raheez Qamar
- Department of Medical Imaging, Sunnybrook Hospital, University of Toronto, Toronto, Canada
| |
Collapse
|
34
|
Gibney B, Redmond CE, Byrne D, Mathur S, Murray N. A Review of the Applications of Dual-Energy CT in Acute Neuroimaging. Can Assoc Radiol J 2020; 71:253-265. [PMID: 32106693 DOI: 10.1177/0846537120904347] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Dual-energy computed tomography (CT) is a promising tool with increasing availability and multiple emerging and established clinical applications in neuroradiology. With its ability to allow characterization of materials based on their differential attenuation when imaged at two different energy levels, dual-energy CT can help identify the composition of brain, neck, and spinal components. Virtual monoenergetic imaging allows a range of simulated single energy-level reconstructions to be created with postprocessing. Low-energy reconstructions can aid identification of edema, ischemia, and subtle lesions due to increased soft tissue contrast as well as increasing contrast-to-noise ratios on angiographic imaging. Higher energy reconstructions can reduce image artifact from dental amalgam, aneurysm clips and coils, spinal hardware, dense contrast, and dense bones. Differentiating iodine from hemorrhage may help guide management of patients after thrombectomy and aid diagnosis of enhancing tumors within parenchymal hemorrhages. Iodine quantification may predict hematoma expansion in aneurysmal bleeds and outcomes in traumatic brain injury. Calcium and bone subtraction can be used to distinguish hemorrhage from brain parenchymal mineralization as well as improving visualization of extra-axial lesions and vessels adjacent to dense plaque or skull. This article reviews the basics of dual-energy CT and highlights many of its clinical applications in the evaluation of acute neurological presentations.
Collapse
Affiliation(s)
- Brian Gibney
- Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Ciaran E Redmond
- Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Danielle Byrne
- Division of Neuroradiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | - Shobhit Mathur
- Department of Medical Imaging, St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Nicolas Murray
- Division of Emergency Radiology, Vancouver General Hospital, Vancouver, British Columbia, Canada
| |
Collapse
|
35
|
|
36
|
Albrecht MH, Vogl TJ, Martin SS, Nance JW, Duguay TM, Wichmann JL, De Cecco CN, Varga-Szemes A, van Assen M, Tesche C, Schoepf UJ. Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT. Radiology 2019; 293:260-271. [DOI: 10.1148/radiol.2019182297] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
37
|
Arendt CT, Czwikla R, Lenga L, Wichmann JL, Albrecht MH, Booz C, Martin SS, Leithner D, Tischendorf P, Blandino A, Vogl TJ, D'Angelo T. Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Eur J Radiol 2019; 122:108666. [PMID: 31786506 DOI: 10.1016/j.ejrad.2019.108666] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 09/04/2019] [Accepted: 09/12/2019] [Indexed: 01/15/2023]
Abstract
PURPOSE To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA). METHOD Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ± 13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques. RESULTS Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (allp < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89). CONCLUSIONS DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality.
Collapse
Affiliation(s)
- Christophe T Arendt
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Rouben Czwikla
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Julian L Wichmann
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Simon S Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - Doris Leithner
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Patricia Tischendorf
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Alfredo Blandino
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina, Messina, Italy
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
| | - Tommaso D'Angelo
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany; Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina, Messina, Italy
| |
Collapse
|
38
|
Zeng Y, Deng K, Yang H, Tan Y, Liu J, Geng D, Zhang J. Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2019; 28:1783-1792. [PMID: 31041597 DOI: 10.1007/s00586-019-05984-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 04/09/2019] [Accepted: 04/19/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the effects of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on reducing metal artefacts compared to traditional virtual monoenergetic imaging (VMI) and linearly blended (M_0.6) reconstructions in patients with lumbar metal internal fixation in dual-energy CT (DECT). METHODS Forty patients who underwent DECT were evaluated in this retrospective study. Images were reconstructed with M_0.6 and with VMI+ and VMI at 10-keV intervals from 40 keV to 190 keV. Attenuation and noise were measured in the hyperdense artefacts, hypodense artefacts, spinal canal, abdominal aorta (AA), and inferior vena cava (IVC). An artefact index (AI) was calculated. A subjective evaluation of the metal-bone interface, surrounding soft tissue, spinal canal, AA, and IVC was conducted. RESULTS The AI values for the hypodense artefacts, spinal canal, and IVC were lowest in the 130 keV VMI+ series, for the hyperdense artefacts in the 120 keV VMI+ series, and for the AA in the 190 keV VMI+ series. Except for the hypodense artefacts, the AI values were lower compared to the M_0.6 images and all the VMI series (all p < 0.05). The subjective image quality was highest at 130 keV VMI+ for the metal-bone interface, surrounding soft tissue, AA, and IVC, and at 120 keV VMI+ for the spinal canal. Except for the AA, these rating scores were higher compared to the M_0.6 images and the entire VMI series (all p < 0.05). CONCLUSIONS DECT with high-keV VMI+ efficiently reduces metal artefacts and shows superior image quality in patients with lumbar internal fixation. These slides can be retrieved from Electronic Supplementary Material.
Collapse
Affiliation(s)
- Yanwei Zeng
- Department of Radiology, Huashan Hospital, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
- Institute of Functional and Molecular Medical Imaging, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
| | - Kai Deng
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China
| | - Haitao Yang
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China
| | - Yi Tan
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China
| | - Jun Liu
- Department of Radiology, Second Xiangya Hospital, Central South University, Changsha, 410011, China.
| | - Daoying Geng
- Department of Radiology, Huashan Hospital, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
- Institute of Functional and Molecular Medical Imaging, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China
| | - Jun Zhang
- Department of Radiology, Huashan Hospital, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China.
- Institute of Functional and Molecular Medical Imaging, Fudan University, No.12 Wulumuqi Road (Middle), Shanghai, 200040, China.
| |
Collapse
|
39
|
D'Angelo T, Cicero G, Mazziotti S, Ascenti G, Albrecht MH, Martin SS, Othman AE, Vogl TJ, Wichmann JL. Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. Br J Radiol 2019; 92:20180546. [PMID: 30919651 DOI: 10.1259/bjr.20180546] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Dual energy CT (DECT) has evolved into a commonly applied imaging technique in clinical routine due to its unique post-processing opportunities for improved evaluation of all body areas. Reconstruction of virtual monoenergetic imaging (VMI) series has shown beneficial effects for both non-contrast and contrast-enhanced DECT due to the flexibility to calculate low-keV VMI reconstructions to increase contrast and iodine attenuation, or to compute high-keV VMI reconstructions to reduce beam-hardening artefacts. The goal of this review article is to explain the technical background of VMI and noise-optimized VMI+ algorithms and to give an overview of useful clinical applications of the VMI technique in DECT of various body regions.
Collapse
Affiliation(s)
- Tommaso D'Angelo
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy.,2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Giuseppe Cicero
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Silvio Mazziotti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Giorgio Ascenti
- 1 Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina , Messina , Italy
| | - Moritz H Albrecht
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Simon S Martin
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Ahmed E Othman
- 3 Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen , Tübingen , Germany
| | - Thomas J Vogl
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| | - Julian L Wichmann
- 2 Department of Diagnostic and Interventional Radiology, Division of Experimental Imaging, University Hospital Frankfurt , Frankfurt , Germany
| |
Collapse
|
40
|
Variation of degree of stenosis quantification using different energy level with dual energy CT scanner. Neuroradiology 2018; 61:285-291. [PMID: 30554271 DOI: 10.1007/s00234-018-2142-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Accepted: 11/20/2018] [Indexed: 11/27/2022]
Abstract
PURPOSE To investigate the variation in the quantification of the carotid degree of stenosis (DoS) with a dual energy computed tomography (CT), using different energy levels during the image reconstruction. METHODS In this retrospective study, 53 subjects (37 males; mean age 67 ± 11 years; age range 47-83 years) studied with a multi-energy CT scanner were included. Datasets were reconstructed on a dedicated workstation and from the CT raw data multiple datasets were generated at the following monochromatic energy levels: 66, 70, 77, and 86 kilo-electronvolt (keV). Two radiologists independently performed all measurements for quantification of the degree of stenosis. Wilcoxon test was used to test the differences between the Hounsifield unit (HU) values in the plaques at different keV. RESULTS The Wilcoxon analysis showed a statistically significant difference (p = 0.001) in the DoS assessment among the different keVs selected. The Bland-Altman analysis showed that the DoS difference had a linear relation with the keV difference (the bigger is the difference in keV, the bigger is the variation in DoS) and that for different keVs, the difference in DoS is reduced with its increase. CONCLUSION A standardization in the use of the energy level during the image reconstruction should be considered.
Collapse
|