1
|
Yin Z, Wu P, Manohar A, McVeigh ER, Pack JD. Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain. Med Phys 2024; 51:4622-4634. [PMID: 38753583 PMCID: PMC11547861 DOI: 10.1002/mp.17088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 03/29/2024] [Indexed: 05/18/2024] Open
Abstract
BACKGROUND Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. PURPOSE A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA). METHODS Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS). RESULTS For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. CONCLUSIONS A detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.
Collapse
Affiliation(s)
- Zhye Yin
- GE HealthCare, Waukesha, WI, USA
| | - Pengwei Wu
- GE HealthCare Technology & Innovation Center, Niskayuna, NY, USA
| | - Ashish Manohar
- Dept. of Medicine, Stanford University, Palo Alto, CA, USA
| | - Elliot R. McVeigh
- Dept. of Bioengineering, Medicine, Radiology at University of California San Diego, San Diego, CA, USA
| | - Jed D. Pack
- GE HealthCare Technology & Innovation Center, Niskayuna, NY, USA
| |
Collapse
|
2
|
Lyoo Y, Choi YH, Lee SB, Lee S, Cho YJ, Shin SM, Phi JH, Kim SK, Cheon JE. Ultra-low-dose computed tomography with deep learning reconstruction for craniosynostosis at radiation doses comparable to skull radiographs: a pilot study. Pediatr Radiol 2023; 53:2260-2268. [PMID: 37488451 DOI: 10.1007/s00247-023-05717-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 06/28/2023] [Accepted: 06/29/2023] [Indexed: 07/26/2023]
Abstract
BACKGROUND Craniofacial computed tomography (CT) is the diagnostic investigation of choice for craniosynostosis, but high radiation dose remains a concern. OBJECTIVE To evaluate the image quality and diagnostic performance of an ultra-low-dose craniofacial CT protocol with deep learning reconstruction for diagnosis of craniosynostosis. MATERIALS AND METHODS All children who underwent initial craniofacial CT for suspected craniosynostosis between September 2021 and September 2022 were included in the study. The ultra-low-dose craniofacial CT protocol using 70 kVp, model-based iterative reconstruction and deep learning reconstruction techniques was compared with a routine-dose craniofacial CT protocol. Quantitative analysis of the signal-to-noise ratio and noise was performed. The 3-dimensional (D) volume-rendered images were independently evaluated by two radiologists with regard to surface coarseness, step-off artifacts and overall image quality on a 5-point scale. Sutural patency was assessed for each of six sutures. Radiation dose was compared between the two protocols. RESULTS Among 29 patients (15 routine-dose CT and 14 ultra-low-dose CT), 23 patients had craniosynostosis. The 3-D volume-rendered images of ultra-low-dose CT without deep learning showed decreased image quality compared to routine-dose CT. The 3-D volume-rendered images of ultra-low-dose CT with deep learning reconstruction showed higher noise level, higher surface coarseness but decreased step-off artifacts, comparable signal-to-noise ratio and overall similar image quality compared to the routine-dose CT images. Diagnostic performance for detecting craniosynostosis at the suture level showed no significant difference between ultra-low-dose CT without deep learning reconstruction, ultra-low-dose CT with deep learning reconstruction and routine-dose CT. The estimated effective radiation dose for the ultra-low-dose CT was 0.05 mSv (range, 0.03-0.06 mSv), a 95% reduction in dose over the routine-dose CT at 1.15 mSv (range, 0.54-1.74 mSv). This radiation dose is comparable to 4-view skull radiography (0.05-0.1 mSv) and lower than previously reported effective dose for craniosynostosis protocols (0.08-3.36 mSv). CONCLUSION In this pilot study, an ultra-low-dose CT protocol using radiation doses at a level similar to skull radiographs showed preserved diagnostic performance for craniosynostosis, but decreased image quality compared to the routine-dose CT protocol. However, by combining the ultra-low-dose CT protocol with deep learning reconstruction, image quality was improved to a level comparable to the routine-dose CT protocol, without sacrificing diagnostic performance for craniosynostosis.
Collapse
Affiliation(s)
- Youngwook Lyoo
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Young Hun Choi
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
| | - Seul Bi Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Seunghyun Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Yeon Jin Cho
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
| | - Su-Mi Shin
- Department of Radiology, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea
| | - Ji Hoon Phi
- Department of Pediatric Neurosurgery, Seoul National University Hospital, Seoul, Republic of Korea
| | - Seung Ki Kim
- Department of Pediatric Neurosurgery, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jung-Eun Cheon
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| |
Collapse
|
3
|
Borgbjerg J, Christensen HS, Al-Mashhadi R, Bøgsted M, Frøkjær JB, Medrud L, Larsen NE, Lindholt JS. Ultra-low-dose non-contrast CT and CT angiography can be used interchangeably for assessing maximal abdominal aortic diameter. Acta Radiol Open 2022; 11:20584601221132461. [PMID: 36246457 PMCID: PMC9561642 DOI: 10.1177/20584601221132461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 09/27/2022] [Indexed: 11/17/2022] Open
Abstract
Background Routine CT scans may increasingly be used to document normal aortic size and to detect incidental abdominal aortic aneurysms. Purpose To determine whether ultra-low-dose non-contrast CT (ULDNC-CT) can be used instead of the gold standard CT angiography (CTA) for assessment of maximal abdominal aortic diameter. Materials and Methods This retrospective study included 50 patients who underwent CTA and a normal-dose non-contrast CT for suspected renal artery stenosis. ULDNC-CT datasets were generated from the normal-dose non-contrast CT datasets using a simulation technique. Using the centerline technique, radiology consultants (n = 4) and residents (n = 3) determined maximal abdominal aortic diameter. The limits of agreement with the mean (LOAM) was used to access observer agreement. LOAM represents how much a measurement by a single observer may plausibly deviate from the mean of all observers on the specific subject. Results Observers completed 1400 measurements encompassing repeated CTA and ULDNC-CT measurements. The mean diameter was 24.0 and 25.0 mm for CTA and ULDNC-CT, respectively, yielding a significant but minor mean difference of 1.0 mm. The 95% LOAM reproducibility was similar for CTA and ULDNC-CT (2.3 vs 2.3 mm). In addition, the 95% LOAM and mean diameters were similar for CTA and ULDNC-CT when observers were grouped as consultants and residents. Conclusions Ultra-low-dose non-contrast CT exhibited similar accuracy and reproducibility of measurements compared with CTA for assessing maximal abdominal aortic diameter supporting that ULDNC-CT can be used interchangeably with CTA in the lower range of aortic sizes.
Collapse
Affiliation(s)
- Jens Borgbjerg
- Department of Radiology, Akershus
University Hospital, Oslo, Norway,Department of Radiology, Aarhus
University Hospital, Aarhus, Denmark,Jens Borgbjerg, Department of Radiology,
Akershus University Hospital, Sykehusveien 25, 1478 Nordbyhagen, Lorenskog 1478,
Norway.
| | - Heidi S Christensen
- Department of Clinical Medicine,
Aalborg University, Aalborg, Denmark; Department of Haematology, Aalborg
University Hospital, Aalborg, Denmark; Clinical Cancer Research Center, Aalborg
University Hospital, Aalborg, Denmark
| | - Rozh Al-Mashhadi
- Department of Clinical Medicine,
Aarhus University, Aarhus, Denmark; Department of Radiology, Aarhus University
Hospital, Aarhus, Denmark
| | - Martin Bøgsted
- Department of Clinical Medicine,
Aalborg University, Aalborg, Denmark; Department of Haematology, Aalborg
University Hospital, Aalborg, Denmark; Clinical Cancer Research Center, Aalborg
University Hospital, Aalborg, Denmark
| | - Jens B Frøkjær
- Mech-Sense, Department of
Radiology, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical
Medicine, Aalborg University, Aalborg, Denmark
| | - Lise Medrud
- Department of Radiology, Aarhus
University Hospital, Aarhus, Denmark
| | | | - Jes S Lindholt
- Department of Cardiac, Thoracic and
Vascular Surgery, Odense University Hospital, Odense, Denmark; Vascular Research
Unit, Regional Hospital Central Denmark, Viborg, Denmark; Department of Clinical
Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
4
|
Barreto IL, Tuna IS, Rajderkar DA, Ching JA, Governale LS. Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality. Pediatr Radiol 2022; 52:85-96. [PMID: 34731286 DOI: 10.1007/s00247-021-05205-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 07/15/2021] [Accepted: 09/09/2021] [Indexed: 11/25/2022]
Abstract
BACKGROUND Children with craniosynostosis may undergo multiple computed tomography (CT) examinations for diagnosis and post-treatment follow-up, resulting in cumulative radiation exposure. OBJECTIVE To reduce the risks associated with radiation exposure, we evaluated the compliance, radiation dose reduction and clinical image quality of a lower-dose CT protocol for pediatric craniosynostosis implemented at our institution. MATERIALS AND METHODS The standard of care at our institution was modified to replace pediatric head CT protocols with a lower-dose CT protocol utilizing 100 kV, 5 mAs and iterative reconstruction. Study-ordered, protocol-utilized and radiation-dose indices were collected for studies performed with routine pediatric brain protocols (n=22) and with the lower-dose CT protocol (n=135). Two pediatric neuroradiologists evaluated image quality in a subset (n=50) of the lower-dose CT studies by scoring visualization of cranial structures, confidence of diagnosis and the need for more radiation dose. RESULTS During the 30-month period, the lower-dose CT protocol had high compliance, with 2/137 studies performed with routine brain protocols. With the lower-dose CT protocol, volume CT dose index (CTDIvol) was 1.1 mGy for all patients (0-9 years old) and effective dose ranged from 0.06 to 0.22 mSv, comparable to a 4-view skull radiography examination. CTDIvol was reduced by 98% and effective dose was reduced up to 67-fold. Confidence in diagnosing craniosynostosis was high and more radiation dose was considered unnecessary in all studies (n=50) by both radiologists. CONCLUSION Replacing the routine pediatric brain CT protocol with a lower-dose CT craniosynostosis protocol substantially reduced radiation exposure without compromising image quality or diagnostic confidence.
Collapse
Affiliation(s)
- Izabella L Barreto
- Division of Medical Physics, Department of Radiology, University of Florida, P.O. Box 100374, Gainesville, FL, 32610, USA.
| | - Ibrahim S Tuna
- Department of Radiology, University of Florida, Gainesville, FL, USA
| | | | - Jessica A Ching
- Division of Plastic and Reconstructive Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA.,Craniofacial Center, UF Health Shands Children's Hospital, Gainesville, FL, USA
| | - Lance S Governale
- Craniofacial Center, UF Health Shands Children's Hospital, Gainesville, FL, USA.,Division of Pediatric Neurosurgery, Department of Neurosurgery, University of Florida, Gainesville, FL, USA
| |
Collapse
|
5
|
Gricienė B, Šiukšterytė M. Local Diagnostic Reference Levels for Paediatric Head CT Procedures. Acta Med Litu 2021; 28:253-261. [PMID: 35474931 PMCID: PMC8958655 DOI: 10.15388/amed.2021.28.2.13] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/21/2021] [Accepted: 06/08/2021] [Indexed: 12/02/2022] Open
Abstract
Background. Patients, especially children, are exposed to substantially high doses of ionising radiation during computed tomography (CT) procedures. Children are several times more susceptible to ionising radiation than adults. Diagnostic reference levels (DRLs) are an important tool for monitoring and optimising patient radiation exposure from radiological procedures. The aim of this study is to estimate the ionising radiation exposure doses and set local DRLs for head CT examinations according to age and to compare local DRLs with national and European DRLs and with literature data in other countries. Materials and methods. Scan parameters of single-phase head CT examinations were collected. Patients were grouped by age in the following intervals: <1, 1−5, 5−10, 10−15 and 15−18 years. Local age-based DRLs set as the 3rd quartile of the median dose-length product (DLP) were calculated. Literature analysis was performed on PubMed search engine on inclusion criteria: publication date 2015–2020, used keywords paediatric computed tomography, paediatric CT, diagnostic reference levels (DRLs). The 23 articles discussing paediatric DRLs were further analysed. Results. Data was collected from 194 paediatric head CT examinations performed in 2019. The median DLP values for head CT were 144.3, 233.7, 246.4, 288.9, 315.5 for <1, 1−5, 5−10, 10−15 and 15−18 years old groups. Estimated local DRLs for head CT examinations are 170, 300, 310, 320, 360 mGy*cm for <1, 1−5, 5−10, 10−15 and 15−18 years age groups respectively and 130, 210, 275, 320 mGy*cm for 0−3 months, 3 months−1 year, 1−6 years and ≥ 6 years age groups respectively. Conclusions. Results of this study showed that settled new local DRLs of head CT examinations were 2–4 times lower than national DRLs and about 2 times lower than European DRLs. Moreover, the study indicated that paediatric head CT doses are significantly lower in comparison with those indicated in the majority of published data from other hospitals over the last 6 years. Patient dose assessment and local DRLs establishment plays important role in future exposure optimisation.
Collapse
|
6
|
Yang MX, Chen B, Zhang YP, Zhao ZH. Feasibility of customizing titanium implant with three-dimensional CT imaging of low dose in skull. Medicine (Baltimore) 2020; 99:e21009. [PMID: 32664105 PMCID: PMC7360305 DOI: 10.1097/md.0000000000021009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
OBJECT To explore the feasibility and practicability of making virtual three-dimensional model of skull defect and customizing titanium implant by skull three-dimensional CT examination of low dose. METHODS Sixty patients with skull defects who underwent skull three-dimensional CT before cranioplasty were randomly divided into 4 groups: group A (conventional dose 120 peak Kilovoltage (kVp), 150 tube current time product (mAs)), low dose group B (120 kVp, 50 mAs), low dose group C (100 kVp, 50 mAs), low dose group D (100 kVp, 30 mAs). After the scanning, we compared radiation doses and image quality among the groups. The CT data were sent to the reconstruction company to produce accurate titanium implants, and neurosurgeons performed cranioplasty. After the operation, patients immediately underwent head CT scans to confirm the accuracy of the implantation position, and a series of clinical functions were evaluated. RESULTS There were significant differences in dose length product (DLP) and effective dose (ED) among the 4 groups (P < .001). The volume CT dose index (CDTIvol), DLP, and ED in group D were, respectively, 87.1%, 86.9%, and 87.3% lower than those in group A (P < .001). All images quality were at or above the general level, and there was no statistical difference (P > .05). Titanium implants were successfully manufactured, every cranioplasty was carried out smoothly, and the clinical function of patients recovered well. CONCLUSION Customizing titanium implant with three-dimensional CT imaging of low dose in skull not only met the clinical requirements, but also significantly reduced the radiation dose and hazard.
Collapse
Affiliation(s)
- Min-Xia Yang
- Department of Radiology, Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, Zhejiang Province, China
| | | | | | | |
Collapse
|
7
|
Elhamiasl M, Nuyts J. Low-dose x-ray CT simulation from an available higher-dose scan. ACTA ACUST UNITED AC 2020; 65:135010. [DOI: 10.1088/1361-6560/ab8953] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
8
|
Reimer RP, Flatten D, Lichtenstein T, Zopfs D, Neuhaus V, Kabbasch C, Maintz D, Borggrefe J, Große Hokamp N. Virtual Monoenergetic Images from Spectral Detector CT Enable Radiation Dose Reduction in Unenhanced Cranial CT. AJNR Am J Neuroradiol 2019; 40:1617-1623. [PMID: 31537517 DOI: 10.3174/ajnr.a6220] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 08/05/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Our aim was to evaluate whether improved gray-white matter differentiation in cranial CT by means of 65- keV virtual monoenergetic images enables a radiation dose reduction compared to conventional images. MATERIALS AND METHODS One hundred forty consecutive patients undergoing 171 spectral detector CTs of the head between February and November 2017 (56 ± 19 years of age; male/female ratio, 56%/44%) were retrospectively included. The tube current-time product was reduced during the study period, resulting in 61, 55, and 55 patients being examined with 320, 290, and 260 mAs, respectively. All other scanning parameters were kept identical. The volume CT dose index was recorded. ROIs were placed in gray and white matter on conventional images and copied to identical positions in 65- keV virtual monoenergetic images. The contrast-to-noise ratio was calculated. Two radiologists blinded to the reconstruction technique evaluated image quality on a 5-point Likert-scale. Statistical assessment was performed using ANOVA and Wilcoxon test adjusted for multiple comparisons. RESULTS The mean volume CT dose index was 55, 49.8, and 44.7 mGy using 320, 290, and 260 mAs, respectively. Irrespective of the volume CT dose index, noise was significantly lower in 65- keV virtual monoenergetic images compared with conventional images (65- keV virtual monoenergetic images/conventional images: extraocular muscle with 49.8 mGy, 3.7 ± 1.3/5.6 ± 1.6 HU, P < .001). Noise slightly increased with a reduced radiation dose (eg, extraocular muscle in conventional images: 5.3 ± 1.4/5.6 ± 1.6/6.1 ± 2.1 HU). Overall, the contrast-to-noise ratio in 65- keV virtual monoenergetic images was superior to that in conventional images irrespective of the volume CT dose index (P < .001). Particularly, 65-keV virtual monoenergetic images with 44.7 mGy showed significantly lower noise and a higher contrast-to-noise ratio than conventional images with 55 mGy (P < .001). Subjective analysis confirmed better image quality in 65- keV virtual monoenergetic images, even using 44.7 mGy. CONCLUSIONS The 65-keV virtual monoenergetic images from spectral detector CT allow radiation dose reduction in cranial CT. While this proof of concept included a radiation dose reduction of 19%, our data suggest that even greater reduction appears achievable.
Collapse
Affiliation(s)
- R P Reimer
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - D Flatten
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - T Lichtenstein
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - D Zopfs
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - V Neuhaus
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - C Kabbasch
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - D Maintz
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - J Borggrefe
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - N Große Hokamp
- From the Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
| |
Collapse
|