Urikura A, Ishii I, Sone M, Sugawara S, Itou C, Kimura S, Suzuki H, Ishihara T, Kusumoto M. Preliminary phantom study of four-dimensional computed tomographic angiography for renal artery mapping: Low-tube voltage and low-contrast volume imaging with deep learning-based reconstruction. Radiography (Lond) 2025; 31:102929. [PMID: 40147091 DOI: 10.1016/j.radi.2025.102929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2025] [Revised: 03/09/2025] [Accepted: 03/13/2025] [Indexed: 03/29/2025]
Abstract
INTRODUCTION A hybrid angio-CT system with 320-row detectors and deep learning-based reconstruction (DLR), provides additional imaging via 4D-CT angiography (CTA), potentially shortening procedure time and reducing DSA acquisitions, contrast media, and radiation dose. This study evaluates the feasibility of low-tube voltage 4D-CTA with low-contrast volume and DLR for selective renal artery embolization using a vessel phantom. METHODS A custom-made phantom simulating contrast-enhanced vessels filled with contrast medium was scanned. The study assessed image quality under varying image noise and vessel contrast. Quantitative analysis included peak contrast-to-noise ratio (pCNR) and image noise. Qualitative assessment was performed by seven radiologists using a 4-point scale; each radiologist independently recorded their evaluations on an assessment sheet. RESULTS A pCNR of approximately 15.0 was identified as the threshold for acceptable image quality. The pCNR decreased as the noise index increased (by 25-75 % when comparing a noise index of 30-70 HU).Vessels with a CT value of 500 Hounsfield units (HU) achieved sufficient image quality with a noise index of 50 HU. Dose reduction was substantial compared to traditional DSA, with effective radiation dose remaining within acceptable clinical levels. CONCLUSION 4D-CTA, combined with DLR, demonstrated the potential to reduce radiation and contrast agent usage while preserving diagnostic quality for renal artery angiography. Further clinical validation is required to confirm these findings in clinical settings. IMPLICATIONS FOR PRACTICE 4D-CTA with low-tube voltage and deep learning-based reconstruction (DLR) can reduce radiation and contrast use while maintaining image quality. This approach might improve safety, particularly in patients with renal impairment, and serve as a viable alternative to conventional DSA for selective renal artery embolization.
Collapse
Affiliation(s)
- A Urikura
- Department of Radiological Technology, Radiological Diagnosis, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
| | - I Ishii
- Department of Radiological Technology, Radiological Diagnosis, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan; Department of Radiological Technology, Fukuyama Medical Center, 14-17, 4-chome, Okinogami-cho, Fukuyama City, Hiroshima, Japan
| | - M Sone
- Department of Diagnostic Radiology/Interventional Radiology Center, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 1040045, Japan
| | - S Sugawara
- Department of Diagnostic Radiology/Interventional Radiology Center, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 1040045, Japan
| | - C Itou
- Department of Diagnostic Radiology/Interventional Radiology Center, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 1040045, Japan
| | - S Kimura
- Department of Diagnostic Radiology/Interventional Radiology Center, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 1040045, Japan
| | - H Suzuki
- Department of Radiological Technology, Radiological Diagnosis, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - T Ishihara
- Department of Radiological Technology, Radiological Diagnosis, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - M Kusumoto
- Department of Diagnostic Radiology, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 1040045, Japan
| |
Collapse
|
2
|
Williams C, Biffin L, Franich R. A model for estimating peak skin dose in CT. Phys Eng Sci Med 2024; 47:539-550. [PMID: 38451465 DOI: 10.1007/s13246-024-01384-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 01/03/2024] [Indexed: 03/08/2024]
Abstract
In interventional radiology patient care can be improved by accurately assessing peak skin dose (PSD) from procedures, as it is the main predictor for tissue-reactions such as erythema. Historically, high skin dose procedures performed in radiology departments were almost exclusively planar fluoroscopy. However, with the increase in use of technologies involving repeated or adjacent computed tomography (CT) such as CT fluoroscopy and multi-modality rooms, the peak skin dose delivered by CT needs to be considered. In this paper, a model to estimate the PSD delivered to a patient undergoing CT has been developed to assist in determining the overall PSD. This model relates the PSD to the device-reported CT Dose Index (CTDIvol) by accounting for a variety of CT technique and patient factors. It includes a novel method for estimating dose contributions as a function of patient or phantom size, scanner geometry, and physical measurement of lateral and depth-based beam profiles. Physical measurements of PSD using radiochromic film on several phantoms have been used to determine needed model parameters. The resulting fitted model was found to agree with measured data to a standard deviation of 5.1% for the data used to fit the model, and 6.8% for measurements that were not used for fitting the model. Two methods for adapting the model for specific scanners are provided, one based on local PSD measurements with radiochromic film and another using CTDIvol measurements. The model, when suitably adapted, can accurately assess individual patients' CT PSD. This information can be integrated with radiation exposure data from other modalities, such as planar fluoroscopy, to predict the overall risk of tissue reactions, allowing for more tailored patient care.
Collapse
Affiliation(s)
- Chris Williams
- Canberra Health Services Medical Physics and Radiation Engineering, Canberra, ACT, Australia.
| | | | | |
Collapse
|
3
|
Helical CT versus intermittent CT fluoroscopic guidance for musculoskeletal needle biopsies: impact on radiation exposure, procedure time, diagnostic yield, and adverse events. Skeletal Radiol 2022; 52:1119-1126. [PMID: 36355218 DOI: 10.1007/s00256-022-04226-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Image-guided percutaneous needle biopsies are essential in the workup of musculoskeletal (MSK) lesions. While helical CT (HCT) is well established, intermittent CT fluoroscopy (iCTF) is an increasingly used alternative. The purpose of this study is to establish whether differences in subject radiation exposure, procedure time, yield, or adverse events exist between HCT and iCTF guidance. MATERIALS AND METHODS This retrospective cohort study included consecutive MSK needle biopsies performed on a single-CT scanner over a 12-month period at a tertiary academic center. Subject demographics, radiation dose, and outcomes were abstracted from the medical record. Comparisons between the two cohorts were performed using Student's t-test for continuous data and using Fisher's exact test for categorical data and a two-tailed p value less than 0.05 was considered significant. RESULTS Two hundred sixteen adults (115 (53.2%) females) with a mean age of 58.8 ± 18.4 years, underwent 216 biopsies (109 (50.5%) HCT guided, 107 (49.5%) iCTF guided) between June 2017 and June 2018. Dose-length product (DLP) and volume CT dose index (CTDIvol) were significantly higher for the HCT cohort (HCT 698.9 ± 400.8 mGycm vs iCTF 312.8 ± 170.8 mGycm; p < 0.005 and HCT 19.1 mGy ± 8.8 vs iCTF 6.9 mGy ± 1.5, p < 0.001). No significant difference in diagnostic yield, procedure time, or adverse event rate was identified. CONCLUSION For CT-guided MSK needle biopsies, iCTF decreases subject radiation dose compared to HCT without negatively affecting outcomes. iCTF should be strongly considered by radiologists performing MSK biopsies given the reduced patient radiation exposure.
Collapse
|
4
|
Yang H, Zhang MZH, Sun HW, Chai YT, Li X, Jiang Q, Hou J. A Novel Microcrystalline BAY-876 Formulation Achieves Long-Acting Antitumor Activity Against Aerobic Glycolysis and Proliferation of Hepatocellular Carcinoma. Front Oncol 2021; 11:783194. [PMID: 34869036 PMCID: PMC8636331 DOI: 10.3389/fonc.2021.783194] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 10/15/2021] [Indexed: 12/17/2022] Open
Abstract
BAY-876 is an effective antagonist of the Glucose transporter type 1 (GLUT1) receptor, a mediator of aerobic glycolysis, a biological process considered a hallmark of hepatocellular carcinoma (HCC) together with cell proliferation, drug-resistance, and metastasis. However, the clinical application of BAY-876 has faced many challenges. In the presence study, we describe the formulation of a novel microcrystalline BAY-876 formulation. A series of HCC tumor models were established to determine not only the sustained release of microcrystalline BAY-876, but also its long-acting antitumor activity. The clinical role of BAY-876 was confirmed by the increased expression of GLUT1, which was associated with the worse prognosis among advanced HCC patients. A single dose of injection of microcrystalline BAY-876 directly in the HCC tissue achieved sustained localized levels of Bay-876. Moreover, the single injection of microcrystalline BAY-876 in HCC tissues not only inhibited glucose uptake and prolonged proliferation of HCC cells, but also inhibited the expression of epithelial-mesenchymal transition (EMT)-related factors. Thus, the microcrystalline BAY-876 described in this study can directly achieve promising localized effects, given its limited diffusion to other tissues, thereby reducing the occurrence of potential side effects, and providing an additional option for advanced HCC treatment.
Collapse
Affiliation(s)
- Hua Yang
- Department of Medical Oncology, Affiliated Hospital of Hebei University, Hebei Key Laboratory of Cancer Radiotherapy and Chemotherapy, Baoding, China
| | - Mu-Zi-He Zhang
- Department of Pharmacy, Medical Security Center of PLA General Hospital, Beijing, China
| | - Hui-Wei Sun
- Department of Infectious Disease, Institute of Infectious Disease, The Fifth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Yan-Tao Chai
- Department of Infectious Disease, Institute of Infectious Disease, The Fifth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Xiaojuan Li
- Department of Infectious Disease, Institute of Infectious Disease, The Fifth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Qiyu Jiang
- Department of Infectious Disease, Institute of Infectious Disease, The Fifth Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Jun Hou
- Department of Infectious Disease, Institute of Infectious Disease, The Fifth Medical Center of Chinese PLA General Hospital, Beijing, China
| |
Collapse
|