1
|
Lucas K, Melling N, Giannou AD, Reeh M, Mann O, Hackert T, Izbicki JR, Perez D, Grass JK. Lymphatic Mapping in Colon Cancer Depending on Injection Time and Tracing Agent: A Systematic Review and Meta-Analysis of Prospective Designed Studies. Cancers (Basel) 2023; 15:3196. [PMID: 37370806 PMCID: PMC10296374 DOI: 10.3390/cancers15123196] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2023] [Revised: 06/08/2023] [Accepted: 06/13/2023] [Indexed: 06/29/2023] Open
Abstract
An optimized lymph node yield leads to better survival in colon cancer, but extended lymphadenectomy is not associated with survival benefits. Lymphatic mapping shows several colon cancers feature aberrant drainage pathways inducing local recurrence when not resected. Currently, different protocols exist for lymphatic mapping procedures. This meta-analysis assessed which protocol has the best capacity to detect tumor-draining and possibly metastatic lymph nodes. A systematic review was conducted according to PRISMA guidelines, including prospective trials with in vivo tracer application. The risk of bias was evaluated using the QUADAS-2 tool. Traced lymph nodes, total resected lymph nodes, and aberrant drainage detection rate were analyzed. Fifty-eight studies met the inclusion criteria, of which 42 searched for aberrant drainage. While a preoperative tracer injection significantly increased the traced lymph node rates compared to intraoperative tracing (30.1% (15.4, 47.3) vs. 14.1% (11.9, 16.5), p = 0.03), no effect was shown for the tracer used (p = 0.740) or the application sites comparing submucosal and subserosal injection (22.9% (14.1, 33.1) vs. 14.3% (12.1, 16.8), p = 0.07). Preoperative tracer injection resulted in a significantly higher rate of detected aberrant lymph nodes compared to intraoperative injection (26.3% [95% CI 11.5, 44.0] vs. 2.5% [95% CI 0.8, 4.7], p < 0.001). Analyzing 112 individual patient datasets from eight studies revealed a significant impact on aberrant drainage detection for injection timing, favoring preoperative over intraoperative injection (OR 0.050 [95% CI 0.010-0.176], p < 0.001) while indocyanine green presented itself as the superior tracer (OR 0.127 [95% CI 0.018-0.528], p = 0.012). Optimized lymphatic mapping techniques result in significantly higher detection of aberrant lymphatic drainage patterns and thus enable a personalized approach to reducing local recurrence.
Collapse
Affiliation(s)
- Katharina Lucas
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
- Department of Visceral, Thoracic, Vascular Surgery and Angiology, City Hospital Triemli, Birmensdorferstrasse 497, 8063 Zürich, Switzerland
| | - Nathaniel Melling
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| | - Anastasios D. Giannou
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| | - Matthias Reeh
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| | - Oliver Mann
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| | - Thilo Hackert
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| | - Jakob R. Izbicki
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| | - Daniel Perez
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
- Department of General and Visceral Surgery, Asklepios Hospital Altona, Paul-Ehrlich-Straße 1, 22763 Hamburg, Germany
| | - Julia K. Grass
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg, Germany; (K.L.); (N.M.); (A.D.G.); (M.R.); (O.M.); (T.H.); (J.R.I.); (D.P.)
| |
Collapse
|
2
|
Qiao L. Sentinel lymph node mapping for metastasis detection in colorectal cancer: a systematic review and meta-analysis. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2021; 112:722-730. [PMID: 32894022 DOI: 10.17235/reed.2020.6767/2019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
INTRODUCTION controversy exists on the diagnostic performance of sentinel lymph node (SLN) mapping in colorectal cancer. This study aimed to provide a more precise estimation of its clinical significance. MATERIALS AND METHODS a systematic search of electronic databases was conducted to retrieve all relevant studies up to August 31st, 2019. Detection rate, sensitivity, and upstaging rate were pooled together, and a subgroup analysis was performed to identify factors that affect diagnostic performance. The prognostic value of upstaging was also explored. RESULTS sixty-eight studies were eligible and included. The pooled SLN detection rate was 0.93 (95 % CI, 0.91-0.94), with a significant higher rate in colon cancer or in studies including more than 100 patients. The overall sensitivity of the SLN procedure in colorectal cancer was 0.72 (95 % CI, 0.67-0.77). The tracers used were found to influence sensitivity. A mean weighted upstaging of 0.22 (95 % CI, 0.18-0.25) was identified. True upstaging, defined as micro-metastases, was 14 %. Upstaged patients were associated with worse overall survival (OS) when compared with node-negative patients (HR = 2.60, 95 % CI, 0.16-4.63). In addition, upstaged patients had a lower 5-year disease-free survival (DFS) rate than node-negative patients. CONCLUSION based on the results of the present meta-analysis, the SLN mapping procedure should focus on early stage patients to refine staging, since upstaging appeared to be a prognostic factor for DFS and OS. The SLN procedure can be recommended for colorectal cancer patients in addition to conventional resection.
Collapse
Affiliation(s)
- Likui Qiao
- Pathology, Tianjin fourth Center Hospital, China
| |
Collapse
|
3
|
Long M, Luo D, Diao F, Huang M, Huang K, Peng X, Lin S, Li H. A Carbon Nanoparticle Lymphatic Tracer Protected Parathyroid Glands During Radical Thyroidectomy for Papillary Thyroid Non-Microcarcinoma. Surg Innov 2016; 24:29-34. [PMID: 27634477 DOI: 10.1177/1553350616668088] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The study assessed the role of an activated carbon nanoparticle lymphatic tracer in reducing unintentional damage to the parathyroid glands during thyroidectomy for papillary thyroid non-microcarcinoma diagnosed intraoperatively by cryosections. A total of 103 patients with papillary thyroid non-microcarcinomas diagnosed by intraoperative cryosection were randomly assigned to receive routine radical thyroidectomy or radical thyroidectomy following administration of activated carbon nanoparticle lymphatic tracer to the contralateral thyroid, at the department of Thyroid Surgery, Sun Yat-sen Memorial Hospital (Guangzhou, China), between January 2012 and May 2013. The success of level VI lymphadenectomy and postoperative parathyroid function were compared. Administration of the activated carbon nanoparticle lymphatic tracer did not affect the frequency of recovered lymph nodes containing metastases; however, it did significantly reduce the incidence of permanent and transient hypoparathyroidism from 2 to 0 and 18 to 6, and reduced the mean recovery time for transient hypoparathyroidism from 57.0 days to 22.3 days. Administration of activated carbon nanoparticles to the contralateral thyroid after intraoperative cryosections did not contribute to lymphadenectomy for papillary thyroid non-microcarcinoma, but significantly protected parathyroid functions. This approach could decrease the morbidity of radical thyroidectomy and the occurrence of hypoparathyroidism.
Collapse
Affiliation(s)
- Miaoyun Long
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| | - Dingyuan Luo
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| | - Feiyu Diao
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| | | | - Kai Huang
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| | - Xinzhi Peng
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| | - Shaojian Lin
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| | - Honghao Li
- 1 Sun Yat-sen Memorial Hospital, Guangzhou, China
| |
Collapse
|
4
|
van der Zaag ES, Bouma WH, Tanis PJ, Ubbink DT, Bemelman WA, Buskens CJ. Systematic review of sentinel lymph node mapping procedure in colorectal cancer. Ann Surg Oncol 2012; 19:3449-59. [PMID: 22644513 DOI: 10.1245/s10434-012-2417-0] [Citation(s) in RCA: 73] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2011] [Indexed: 12/21/2022]
Abstract
BACKGROUND The clinical impact of sentinel lymph node (SN) biopsy in colorectal cancer is still controversial. The aim of our study was to determine the accuracy of this procedure from published data and to identify factors that contribute to the conflicting reports. METHODS A systematic search of the Medline, Embase, and Cochrane databases up to July 2011 revealed 98 potentially eligible studies, of which 57 were analyzed including 3,934 patients (3,944 specimens). RESULTS The pooled SN identification rate was 90.7% (95% CI 88.2-93.3), with a significant higher identification rate in studies including more than 100 patients or studies using the ex vivo SN technique. The pooled sensitivity of the SN procedure was 69.6% (95% CI 64.7-74.6). Including the immunohistochemical findings increased the pooled sensitivity of SN procedure to 80.2% (95% CI 4.7-10.7). Subgroups with significantly higher sensitivity could be identified: ≥4 SNs versus <4 SNs (85.2 vs. 66.3%, p = 0.003), colon versus rectal cancer (77.6 vs. 65.7%, p = 0.04), early T1 or T2 versus advanced T3 or T4 carcinomas (93.4 vs. 58.8%, p = 0.01). Serial sectioning and immunohistochemistry resulted in a mean upstaging of 18.9% (range 0-50%). True upstaging defined as micrometastases (pN1mi+) rather than isolated tumor cells (pN0itc+) was 7.7%. CONCLUSIONS The SN procedure in colorectal cancer has an overall sensitivity of 70%, with increased sensitivity and refined staging in early-stage colon cancer. Because the ex vivo SN mapping is an easy technique it should be considered in addition to conventional resection in colon cancer.
Collapse
|
5
|
Hao RT, Chen J, Zhao LH, Liu C, Wang OC, Huang GL, Zhang XH, Zhao J. Sentinel lymph node biopsy using carbon nanoparticles for Chinese patients with papillary thyroid microcarcinoma. Eur J Surg Oncol 2012; 38:718-24. [PMID: 22521260 DOI: 10.1016/j.ejso.2012.02.001] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2011] [Revised: 01/15/2012] [Accepted: 02/02/2012] [Indexed: 02/06/2023] Open
Abstract
AIMS To compare the efficacies of methylene blue (MB) and carbon nanoparticles (CNs) as tracers for sentinel lymph node biopsy (SLNB), and assess the value of SLNB in predicting the cervical LN status of patients with thyroid microcarcinoma. METHODS This retrospective analysis comprised 200 thyroid microcarcinoma patients who underwent intraoperative SLNB. Among them, 100 patients were injected with MB dye. The other 100 patients received a CN suspension injection. Routine pathological examination was performed in all resected specimens. RESULTS SLNs detected in the experimental and control groups were 126 and 102, respectively, of which the metastatic LNs confirmed by histopathology were 77 and 48, respectively. The staining rate of cervical level VI LNs in the experimental group was significantly higher than that in the control group (P<0.001). For the CN method, the sensitivity, specificity, accuracy rate, and false negative rate were 93.3%, 100%, 97%, and 5.2%, respectively, whereas the corresponding figures for the MB method were 80.6%, 100%, 93%, and 9.9%, respectively. The positive rate of cancer metastases for SLNs in the experimental group was 61.1%, which is significantly higher than that in the control group (47.1%; P=0.034). CONCLUSIONS In contrast to the MB method, CNs can maintain the durability of SLN imaging and accurately forecast the LN status of patients with thyroid microcarcinoma; in addition, the CN method was found to be feasible and repeatable. The CN method better aids the screening and selection of patients who are most likely to benefit from cervical LN dissection.
Collapse
Affiliation(s)
- R T Hao
- Department of Surgical Oncology, The First Affiliated Hospital of Wenzhou Medical College, Wenzhou 325000, China
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Sentinel-lymph-node procedure in colon and rectal cancer: a systematic review and meta-analysis. Lancet Oncol 2011; 12:540-50. [PMID: 21549638 DOI: 10.1016/s1470-2045(11)70075-4] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND No consensus exists on the validity of the sentinel-lymph-node procedure for assessment of nodal status in patients with colorectal cancer. We aimed to assess the diagnostic performance of this procedure. METHODS We searched Embase and PubMed databases for studies published before March 20, 2010. Eligible studies had a prospective design, a sample size of at least 20 patients, and reported the rate of sentinel-lymph-node positivity. Individual patient data were requested for localisation and T-stage stratification. A subset of reports with high methodological quality was selected and analysed. FINDINGS We identified 52 eligible studies, which included 3767 sentinel-lymph-node procedures (2961 [78·6%] colon and 806 [21·4%] rectal carcinomas). Most tumours 2339 (62·1%) were stage T3 or T4. 1887 (50·1%) of patients were male, 1880 (49·9%) female. Mean overall weighted-detection rate was 0·94 (95% CI 0·92-0·95), at a pooled sensitivity of 0·76 (0·72-0·80) with limited heterogeneity (χ(2)=286·08, degrees of freedom=51; p=0·003). A mean weighted upstaging of 0·15 (95% CI 0·12-0·19) was noted. Individual patient data were available from 19 studies that included 1168 patients. Analysis of these data showed no significant difference in sensitivity between colon (0·86 [95% CI 0·83-0·90]) and rectal cancer (0·82 [0·77-0·88]; p=0·23). Also, there was no dependency of sensitivity on T stage for both colon (pT1: 0·79 [95% CI 0·73-0·84], pT2: 0·76 [0·62-0·90], pT3: 0·73 [0·59-0·87], pT4: 0·73 [0·53-0·93]) and rectal cancer (T1 or T2: 0·81 [0·52-0·94] vs T3 or T4: 0·80 [0·51-0·93]). The subgroup of eight studies with high methodological quality showed a mean detection rate of 0·96 (95% CI 0·90-0·99) for colonic tumours and 0·95 (0·75-0·99) for rectal tumours, and a mean sensitivity of 0·90 (95% CI 0·86-0·93) for colonic tumours and 0·82 (0·60-0·93) for rectal tumours. INTERPRETATION The sentinel-lymph-node procedure shows a low sensitivity, regardless of T stage, localisation, or pathological technique. For every patient diagnosed with colon or rectal cancer without clinical evidence of lymph-node involvement or metastatic disease, this procedure in addition to conventional resection should be considered, since the prognostic information provided by this technique could be clinically significant. FUNDING Cancer Center Amsterdam Foundation, Amsterdam, Netherlands.
Collapse
|
7
|
van der Zaag ES, Kooij N, van de Vijver MJ, Bemelman WA, Peters HM, Buskens CJ. Diagnosing occult tumour cells and their predictive value in sentinel nodes of histologically negative patients with colorectal cancer. Eur J Surg Oncol 2010; 36:350-7. [PMID: 20163930 DOI: 10.1016/j.ejso.2009.11.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2009] [Revised: 11/11/2009] [Accepted: 11/16/2009] [Indexed: 12/13/2022] Open
Abstract
PURPOSE Most studies on the sentinel node (SN) procedure in patients with colorectal cancer include immunohistochemical analysis of the SN only. To evaluate the real diagnostic accuracy of the SN procedure with immunohistochemical analysis, the presence of occult tumour cells in all histologically negative lymph nodes was compared to the presence of these cells in SNs. Also the reproducibility of diagnosing occult tumour cells (OTC) and the sensitivity of three different antibodies was assessed. METHODS Between November 2006 en July 2007, an ex vivo SN procedure was performed in 58 histologically N0 patients with colorectal cancer. All lymph nodes (n = 908, mean 15.7) were step-sectioned and immunohistochemistry was performed using two antibodies against cytokeratins (Cam5.2, and CK 20) and one antibody against BerEp-4. RESULTS OTC were identified in 19 of 58 patients, with micrometastases (0.2-2 mm) in 7 and isolated tumour cells (ITC)(<0.2 mm) in 12 patients. The overall agreement in diagnosing OTC between two independent pathologists was 86%. An SN was identified in 53 of 58 patients. All micrometastases were found in SNs. In two patients with negative SNs, ITC's were demonstrated in non-SNs (sensitivity 88%, and overall accuracy 96%). CONCLUSION Additional immunohistochemical analysis of histologically negative lymph nodes demonstrates occult tumour cells in 33% of the patients resulting in an upstaging rate of 12%. Occult tumour cells are predominantly found in the SN, therefore SN mapping has the potential to refine the staging system for patients with colorectal cancer.
Collapse
Affiliation(s)
- E S van der Zaag
- Department of Surgery, Gelre Ziekenhuizen, Albert Schweitzerlaan 31, 7334 DZ Apeldoorn, The Netherlands.
| | | | | | | | | | | |
Collapse
|