1
|
Manolesou DG, Georgiopoulos G, Lazaris AM, Schizas D, Stamatelopoulos KS, Khir AW, Liakakos T, Papaioannou TG. Experimental Devices Versus Hand-Sewn Anastomosis of the Aorta: A Systematic Review and Meta-Analysis. J Surg Res 2020; 258:200-212. [PMID: 33035743 DOI: 10.1016/j.jss.2020.08.060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 07/27/2020] [Accepted: 08/30/2020] [Indexed: 01/16/2023]
Abstract
BACKGROUND To minimize complications associated with the construction of the hand-sewn aortic anastomosis, alternative experimental methods have been pursued. This study aimed to evaluate the efficacy of experimental anastomotic devices in relation to time and point of rupture of the anastomosis in comparison to the conventional technique. MATERIALS AND METHODS An electronic search was performed using MEDLINE, Scopus, Science Direct, and Cochrane Library databases by two independent authors. Our exclusion criteria referred to studies reporting results solely from end-to-side anastomosis, results on vessels other than the aorta, studies that did not involve animal experiments, and non-English publications. The last search date was January 1, 2020. RESULTS The meta-analysis included 22 studies with 34 anastomosis samples and a total of 316 animals. The pooled mean automated anastomosis time was 10.38 min, and the mean point of rupture was 32.7 N. In the subgroup analysis of automated anastomosis time by device category, the anastomotic stenting technique reported significantly lower anastomosis time but also showed significantly lower point of rupture. Comparing the efficacy of experimental devices and the hand-sewn technique, our pooled analysis showed that automated devices significantly decrease the time needed to perform the anastomosis (weighted mean difference -7.24 min). On the other hand, the automated anastomosis is also associated with decreased tensile strength (weighted mean difference -20.68 N). CONCLUSIONS Although experimental devices seem to offer a faster anastomosis, they lack endurance when compared with the hand-sewn technique. Further research is needed for the development of an "ideal" anastomotic technique.
Collapse
Affiliation(s)
- Danae G Manolesou
- Biomedical Engineering Unit, First Department of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
| | - George Georgiopoulos
- School of Biomedical Engineering and Imaging Sciences, King's College London, London UK
| | - Andreas M Lazaris
- Department of Vascular Surgery, Attikon Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Dimitrios Schizas
- First Department of Surgery, Laiko Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Kimon S Stamatelopoulos
- Vascular Laboratory, Department of Clinical Therapeutics, Alexandra Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Ashraf W Khir
- Brunel Institute for Bioengineering, Brunel University London, London, UK
| | - Theodoros Liakakos
- First Department of Surgery, Laiko Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore G Papaioannou
- Biomedical Engineering Unit, First Department of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
2
|
Manolesou D, Papaioannou TG, Georgiopoulos G, Schizas D, Lazaris A, Stamatelopoulos K, Dimakakos E, Stergiopulos N, Stefanadis C, Liakakos T, Tousoulis D. Α systematic review and meta-analysis of the efficacy of aortic anastomotic devices. J Vasc Surg 2019; 69:598-613.e7. [PMID: 30683205 DOI: 10.1016/j.jvs.2018.08.154] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 08/09/2018] [Indexed: 01/16/2023]
Abstract
OBJECTIVE One of the factors contributing to complications related to open repair of the aorta is the construction of a hand-sewn anastomosis. Aortic anastomotic devices (AADs), such as the intraluminal ringed graft (IRG), and the anastomotic stenting technique have been developed to perform a sutureless and less complicated anastomosis. This study performed a systematic review and meta-analysis of the literature reporting clinical use of AADs and aimed to assess, primarily, the effect of each device on 30-day overall and operation-related mortality and aortic cross-clamping time and, secondarily, the rate of successful two-sided application of the IRG device and the operation-related morbidity for each device. METHODS An electronic search was performed using MEDLINE, Scopus, ScienceDirect, and Cochrane Library by two independent authors. Our exclusion criteria included studies incorporating fewer than three patients and studies reporting results solely from animals or in vitro testing, results solely from end-to-side anastomosis, and results solely from endarterectomy procedures. The last search date was February 1, 2018. RESULTS A total of 41 studies were identified that reported outcomes for the use of three different device types: IRG, anastomotic stenting technique, and surgical staplers. The last two types were classified together as the non-IRG group. The meta-analysis included 27 studies with 50 cohorts incorporating 1260 patients. The median age of the incorporated patients was 61.4 years (range, 51-73 years), and 68.9% were male. The operations were performed for the treatment of acute aortic dissection in 82.3%. The pooled overall 30-day mortality rate varied by device type; IRG devices had a mean rate of all-cause mortality of 9.71%, whereas non-IRG devices were associated with a significantly (I2 = 15.78%; P for Cochrane Q test < .19) lower rate of death (1.47%). The pooled mean aortic cross-clamping time was 35.83 minutes. Metaregression showed that the performance of two-sided anastomosis with the IRG device significantly decreased the aortic cross-clamping time. However, a successful two-sided ringed anastomosis was performed in approximately half of the cases. CONCLUSIONS Taking into account that the majority of operations were performed for the treatment of acute aortic dissection, AADs had a relatively low rate of 30-day mortality. Despite the observed heterogeneity in study protocols and the small sample size in the non-IRG group, the non-IRG group presented with the lowest 30-day mortality rate. Specific device-related complications between the different device types need further investigation.
Collapse
Affiliation(s)
- Danae Manolesou
- Biomedical Engineering Unit, First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
| | - Theodore G Papaioannou
- Biomedical Engineering Unit, First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - George Georgiopoulos
- Vascular Laboratory, Department of Therapeutics, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Dimitrios Schizas
- First Department of Surgery, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Andreas Lazaris
- Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Kimonas Stamatelopoulos
- Vascular Laboratory, Department of Therapeutics, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Evangelos Dimakakos
- Vascular Unit, 3rd Internal Medicine Clinic, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Nikolaos Stergiopulos
- Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Biotechnology, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | | | - Theodoros Liakakos
- First Department of Surgery, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Dimitrios Tousoulis
- Biomedical Engineering Unit, First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
3
|
Liu H, Zhang SJ, Shao YF, Lu XH, Gu WD, Ni BI, Gu Q, Du JJ. Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis. J Biomed Res 2018; 32:454-460. [PMID: 28963444 PMCID: PMC6283826 DOI: 10.7555/jbr.31.20170011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 04/20/2017] [Indexed: 12/04/2022] Open
Abstract
The surgical treatment for aortic diseases remains a challenge for any cardiac surgeon. The use of sutureless ring connector in aortic anastomosis can simplify the procedure and shorten anastomosis time. Therefore, we developed a novel device for sutureless aortic anastomosis. A series of experiments were carried out for tensile and leakproof-capacity assessments to verify the feasibility of the ring connector by using fresh swine aorta samples. In in vivo test, the ring connector was implanted in 6 swine with follow-up of 6 months. Radiographic and pathological studies of the aorta were performed. In the tensile tests, the strength was 32.7±5.9 Newton (N) in the sutureless anastomosis group, compared with 73.3±12.5 N in the control group by traditional manual suture. In the leakproof-capacity assessment, no sign of either leakage or bursting was evident at 280 mmHg of internal pressure in the aorta samples. In in vivo tests, it took 9.47±0.3 minutes for the sutureless anastomosis, compared with 15.58±1.39 minutes for hand-sewn suturing. Insertion was easy and rapid. Radiographic and pathological studies were performed at first month, third month and sixth month after surgery, each time obtained from the two swine, showed patency of the anastomosis and no signs of stenosis, blood leakage, migration or pseudoaneurysm formation, except one paralyzed swine developed of thrombo-occlusion at the site of the sutureless anastomosis. The result indicates that this novel ring connector offers considerable promise for sutureless aortic anastomosis.
Collapse
Affiliation(s)
- Huan Liu
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Shi-jiang Zhang
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Yong-feng Shao
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Xiao-hu Lu
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Wei-dong Gu
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Buq-ing Ni
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Qun Gu
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| | - Jun-jie Du
- Department of Cardiovascular Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, Jiangsu 210029, China
| |
Collapse
|
4
|
Kapischke M, Gerhard D, Pries A. Sutureless open vascular anastomosis connector: An experimental study. Vascular 2016; 25:101-104. [DOI: 10.1177/1708538116669065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The objective of this study was to assess the safety of a new developed sutureless vascular adapter system in a porcine model. In five pigs, 4-cm-long polyester prosthesis (6 mm diameter) were implanted and anastomosed with the newly developed adapter proximally and suture anastomosis distally. The integration of the adapter was investigated in comparison to the suture anastomosis. These investigations were performed by light microscopy and scanning electron microscopy. Median operative time for performing the adapter anastomosis was significantly shorter compared to suture anastomosis (66 s vs. 246 s, p < 0.05). Median estimated blood loss during adapter anastomosis implementation was 22.5 mL (range 19.0–25.0 mL) compared to 48.2 mL (range 45.4–63.5 mL, p < 0.05). In five hand-sewn anastomoses, overall eight additional stitches were necessary whereas all adapter anastomoses showed primary leak tightness. This in vivo study shows the technical feasibility of the newly developed adapter.
Collapse
|
5
|
Idrees JJ, Yazdchi F, Soltesz EG, Vekstein AM, Rodriguez C, Roselli EE. Outcomes after aortic graft-to-graft anastomosis with an automated circular stapler: A novel approach. J Thorac Cardiovasc Surg 2016; 152:1052-7. [PMID: 27449353 DOI: 10.1016/j.jtcvs.2016.06.039] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2016] [Revised: 06/01/2016] [Accepted: 06/08/2016] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Patients with complex aortic disease often require multistaged repairs with numerous anastomoses. Manual suturing can be time consuming. To reduce ischemic time, a circular stapling device has been used to facilitate prosthetic graft-to-graft anastomoses. Objectives are to describe this technique and assess outcomes. METHODS From February 2009 to May 2014, 44 patients underwent complex aortic repair with a circular end-to-end anastomosis (EEA) stapler at Cleveland Clinic. All patients had extensive aneurysms: 17 after ascending dissection repair, 10 chronic type B dissections, and 17 degenerative aneurysms. Stapler was used during total arch repair as an end-to-side anastomosis (n = 36; including first stage elephant trunk [ET] in 32, frozen ET in 3) and an end-to-end anastomosis during redo thoracoabdominal repair (n = 11). Three patients had the stapler used during both stages of repair. Patients underwent early and annual follow-ups with computed tomography analysis. RESULTS There were no bleeds, ruptures, or leaks at the stapled site, but 2 patients died. Complications included 7 reoperations not related to the site of stapled anastomosis and 6 tracheostomies, but there was no paralysis or renal failure. Mean circulatory arrest time was 16 ± 5 minutes. Mean follow-up was 26 ± 17 months and consisted of imaging before discharge, at 3 to 6 months, and at 1 year. Planned reinterventions included 21 second-stage ET completion: Endovascular (n = 18) and open (n = 3). There were 4 late deaths. CONCLUSIONS Use of an end-to-end anastomotic automated circular stapler is safe, effective, and durable in performing graft-to-graft anastomoses during complex thoracic aortic surgery. Further evaluation and refinement of this technique are warranted.
Collapse
Affiliation(s)
- Jay J Idrees
- Aorta Center, Cleveland Clinic, Cleveland, Ohio; Department of Thoracic and Cardiovascular Surgery, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Farhang Yazdchi
- Department of Thoracic and Cardiovascular Surgery, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Edward G Soltesz
- Aorta Center, Cleveland Clinic, Cleveland, Ohio; Department of Thoracic and Cardiovascular Surgery, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Andrew M Vekstein
- Department of Thoracic and Cardiovascular Surgery, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Christopher Rodriguez
- Department of Thoracic and Cardiovascular Surgery, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Eric E Roselli
- Aorta Center, Cleveland Clinic, Cleveland, Ohio; Department of Thoracic and Cardiovascular Surgery, Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio.
| |
Collapse
|
6
|
Instrumento de grapado quirúrgico vascular para realizar una sutura mecánica entre un vaso sanguíneo y una prótesis sintética. ANGIOLOGIA 2015. [DOI: 10.1016/j.angio.2014.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Abou Taam S, Garbé JF, Boufi M, Berdah S, Bossavy JP. Preliminary experimental study of a mechanical connector allowing vascular anastomosis. Ann Vasc Surg 2013; 27:638-45. [PMID: 23403327 DOI: 10.1016/j.avsg.2012.11.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2011] [Revised: 07/21/2011] [Accepted: 11/30/2012] [Indexed: 11/17/2022]
Abstract
BACKGROUND Aortic clamping time needed to carry out anastomosis during aortic surgery is one of the major predictive factors of morbidity/mortality. Because of the difficulties inherent in this technique, the duration of aortic clamping can be increased significantly with laparoscopy, which may explain why this kind of surgery is not often undertaken. We designed an original connector that will help us perform automated end-to-end vascular anastomoses. This anastomotic device was tested on a cadaver, test benches, and finally on pigs. METHODS The connector consists of a bare-metal stent with spikes covering its outer surface. Once the prosthesis has been introduced into the arterial lumen over a 15-mm length, the connector is placed into the prosthesis; then, upon inflating a balloon and employing stent spikes, the prosthesis can be anchored in the artery. A feasibility study was carried out, first on cadaveric arteries and then on bench tests. In vivo, using this connector, the infrarenal aorta of 7 pigs was replaced with a 6-8-mm-diameter prosthesis. One to 42 days after implantation, angiography was performed before explanting the prosthesis. Evaluation criteria included anastomosis performance time, leakproofing capacity, tensile strength, patency, and histologic changes induced by the device. RESULTS On the cadavers, manual traction tests showed that the anastomoses were satisfactory. Median force needed to rupture an automated anastomosis was 15.85 N. No leakage was seen under a systolic/diastolic pressure of up to 250/180 mm Hg. All pigs benefited from automated anastomosis. Once the designed device had been assessed, the median connection time was 2 minutes. In 4 cases, aortic thrombosis was found, 1 of which was septic. The implanting ancillary was responsible for 2 posterior aortic wall perforations, which extended the clamping time; therefore, this device should be modified. Anastomosis patency and tensile strength tests were satisfactory. Histologic results showed the connector incorporation, integration of the spikes in the arterial wall, and the absence of inflammation in the aortic wall. CONCLUSIONS These preliminary studies confirm that the connector is quick and reliable for performing in vivo arterioprosthetic anastomoses. Further studies are needed to improve the ancillary device, which will enable its use it in laparoscopic and conventional surgery.
Collapse
Affiliation(s)
- Salam Abou Taam
- Service de Chirurgie Vasculaire, CHU Toulouse, Toulouse, France.
| | | | | | | | | |
Collapse
|
8
|
Taam SA, Garbé JF, Boufi M, Bossavy JP, Ricco JB. Experimental study of a novel mechanical connector for sutureless open arterial anastomosis. J Vasc Surg 2012; 55:210-5. [DOI: 10.1016/j.jvs.2011.07.082] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2011] [Revised: 07/28/2011] [Accepted: 07/28/2011] [Indexed: 11/30/2022]
|
9
|
Cagiannos C, Kolvenbach RR. Laparoscopic surgery in the management of complex aortic disease: techniques and lessons learned. Vascular 2009; 17 Suppl 3:S119-28. [PMID: 19919802 DOI: 10.2310/6670.2009.00061] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Laparoscopic vascular surgery must be assessed in the context of both open and endovascular interventions. The development of improved laparoscopic equipment and endoscopic techniques makes performance of laparoscopy easier, but endovascular interventions still hold wide appeal because they are minimally invasive and are easier to master by vascular surgeons. Despite decreased morbidity and recovery time, endovascular interventions have inferior durability and higher reintervention rates when compared with open aortoiliac interventions. In particular, after endovascular aneurysm repair, patients need lifelong surveillance because there is potential for delayed endoleaks, aortic neck dilatation, graft migration, and ongoing risk of aneurysmal rupture. These limitations of endovascular therapy are the impetus behind the pursuit of other minimally invasive techniques, such as laparoscopy, in vascular surgery. Currently, two evolving laparoscopic approaches are available for abdominal vascular surgery: total laparoscopic aortic surgery and hybrid techniques that combine laparoscopy with endovascular techniques to treat failing endografts.
Collapse
Affiliation(s)
- Catherine Cagiannos
- Division of Vascular Surgery and Endovascular Therapy, Michael E, DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX, USA
| | | |
Collapse
|
10
|
Alimi Y, Saint Lebes B, Garitey V, Afrapoli A, Boufi M, Hartung O, Garcia S, Mouret F, Berdah S. A Clampless and Sutureless Aorto-Prosthetic End-to-Side Anastomotic Device: An Experimental Study. Eur J Vasc Endovasc Surg 2009; 38:597-602. [DOI: 10.1016/j.ejvs.2009.07.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2009] [Accepted: 07/05/2009] [Indexed: 11/29/2022]
|
11
|
Jansen SJ, Ducke W, Hartley DE, Semmens JB, Lawrence-Brown MMD. A Laparoscopic Endovascular Aortobifemoral Conduit That Can Be Retained as a Long-term Bypass: A Solution for Patients With Inadequate Iliac Access. J Endovasc Ther 2009; 16:114-9. [DOI: 10.1583/08-2417.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
12
|
Millon A, Boufi M, Garitey V, Ramos-Clamote J, Hakam Z, Mouret F, Chevalier J, Alimi Y. Evaluation of a New Vascular Suture System for Aortic Laparoscopic Surgery: An Experimental Study on Pigs and Cadavers. Eur J Vasc Endovasc Surg 2008; 35:730-6. [DOI: 10.1016/j.ejvs.2007.12.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2007] [Accepted: 12/13/2007] [Indexed: 11/29/2022]
|