1
|
Abatzis-Papadopoulos M, Tigkiropoulos K, Nikas S, Sidiropoulou K, Alexou C, Kostopoulou O, Stavridis K, Karamanos D, Lazaridis I, Saratzis N. Endograft Anaconda in Endovascular Aneurysm Repair: A Systematic Review of Literature and Meta-Analysis. Ann Vasc Surg 2024; 104:93-109. [PMID: 37468059 DOI: 10.1016/j.avsg.2023.06.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 06/16/2023] [Accepted: 06/25/2023] [Indexed: 07/21/2023]
Abstract
BACKGOUND The number of endovascular abdominal aortic aneurysm repairs (EVARs) has surpassed the number of open surgical repair of AAAs worldwide with a great variety of endografts being available. The aim of this study is to conduct a systematic review of the literature and meta-analysis of studies reporting patients with infrarenal abdominal aortic aneurysm (AAA) subjected to EVAR with the Anaconda endograft. METHODS We performed a systematic review of multiple electronic databases for studies including patients with infrarenal AAA who were subjected to elective EVAR with Anaconda endograft exclusively. We conducted a proportional meta-analysis cumulating the results of the included studies. The endpoints were first month overall mortality, first and second-year survival after EVAR, AAA-related deaths, incidence of endoleaks, endograft migration, endograft occlusion, open conversion, and primary and secondary technical success. The mean value for each separate studied factor was calculated, and the respective percentage or incidence was extracted so that it can be compared to endograft outcome studies in the literature. We assessed the methodologic quality of studies by using the Briggs Institute critical appraisal tool. RESULTS Seven observational studies were found including 954 patients (males 91.9%, mean age 73.38 ± 6.97 years). The mean transverse diameter of AAAs was 56.83 ± 9.97 mm. The mean proximal aortic neck diameter and length were 23.06 ± 3.33 mm and 24.14 ± 12.16 mm, respectively. Increased aortic neck calcification and aortic neck thrombus were present in 12.5% of patients. The 30-day overall mortality post-EVAR was 1.3%, 1 and 2-year survival rates were 95.9% and 91.4%, respectively. The mean follow-up period in the studies was 46.59 ± 15.5 months. AAA-related mortality was 1.3%. Primary technical success was 97.9% and secondary success was 99.3%. Open conversion was required in 3.4% of all patients (0.6% during the primary operation [Prim. Op]). The most common endoleak was type II, reported in 17.4% of all patients. Early type Ia endoleak was reported in 1.5% of patients and late type Ia in 1.7%. Overall, 2 endoleaks type III and 1 type IV were reported. Endograft migration occurred in 1.7% of patients. Main body and/or one/both iliac legs thrombotic occlusion was found totally in 7.6% of patients (5 main body occlusions and 64 iliac leg occlusions). CONCLUSIONS The use of Anaconda endograft in electively treated patients with infrarenal AAAs presented good results with high technical success and low postoperative and mid-term complications, except for an increased incidence of stent-graft thrombosis, which seems to be the "Achilles heel" of the device.
Collapse
Affiliation(s)
- Manolis Abatzis-Papadopoulos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece.
| | - Konstantinos Tigkiropoulos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Spyridon Nikas
- Radiology Department, General Hospital of Veroia, Veroia, Greece
| | - Katerina Sidiropoulou
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Christina Alexou
- Department of Nursing (Thessaloniki), School of Health Sciences, International Hellenic University, Thessaloniki, Greece
| | - Olympia Kostopoulou
- Internal Medicine Department, General Hospital of Katerini, Katerini, Greece
| | - Kyriakos Stavridis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Dimitrios Karamanos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Ioannis Lazaridis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Nikolaos Saratzis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| |
Collapse
|
2
|
Chaudhuri A, Abisi S, Badawy A. Percutaneous mechanical thrombectomy for limb graft occlusion after endovascular aneurysm repair: Results of a case series. Vascular 2024; 32:546-549. [PMID: 36724505 DOI: 10.1177/17085381231155670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Limb graft occlusion (LGO) is a recognised complication after endovascular aneurysm repair (EVAR). We present outcomes of a case series of LGO treated by percutaneous mechanical thrombectomy (PMT). METHODS Six male patients (mean age 70.5 ± 7.5 years) presented with LGO after EVAR (n = 4), fenestrated EVAR with an iliac branch device (n = 1), branched EVAR (n = 1). Median time to occlusion was 28.5(IQR 90) weeks; all occlusions were unilateral. The presenting symptom was intermittent claudication (n = 4), chronic limb-threatening ischaemia (n = 1) or acute limb ischaemia (n = 1). PMT was undertaken using the 10F Rotarex Rotational Excisional Atherectomy System (Becton, Dickinson and Company, Franklin Lakes, USA) with optional stenting/reline of the affected limb. RESULTS LGO was cleared in all 6 cases by PMT with limb stenting (n = 4)/limb reline (n = 2)/outflow stenting (n = 2). Post-operatively, novel oral anticoagulant therapy supplemented prior antiplatelet therapy in all cases. Length of stay was 2 (IQR 19) days. All cleared limbs remain patent at median 15 (IQR 185) weeks follow-up. CONCLUSION This case series indicates that percutaneous mechanical thrombectomy is associated with high technical success rates and subsequent acceptable ensuing short-to-midterm patency. This approach is a valid alternative to surgical interventions in such cases, and represents our primary approach when LGO is encountered after EVAR.
Collapse
Affiliation(s)
- Arindam Chaudhuri
- Bedfordshire - Milton Keynes Vascular Centre, Bedford Hospital NHS Trust, Bedford, UK
| | | | - Ayman Badawy
- Bedfordshire - Milton Keynes Vascular Centre, Bedford Hospital NHS Trust, Bedford, UK
| |
Collapse
|
3
|
Kontes I, Bontinis V, Bontinis A, Manaki V, Chorti A, Giannopoulos A, Ktenidis K. Sequential Graft Limb Occlusion Following Endovascular Aneurysm Repair: A Case Report and Literature Review. Cureus 2024; 16:e60102. [PMID: 38860102 PMCID: PMC11164407 DOI: 10.7759/cureus.60102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/10/2024] [Indexed: 06/12/2024] Open
Abstract
Limb graft occlusion (LGO) is a common complication that can occur after endovascular aneurysm repair (EVAR). There are many factors that can contribute to LGO, including patient-related variables, device-related considerations, and factors associated with the procedural technique. Patients with LGO may exhibit no symptoms, have intermittent claudication, or suffer from acute limb ischemia. In this manuscript, we present a case of a 64-year-old male who experienced sequential LGOs after EVAR accompanied by a comprehensive review of the pertinent literature.
Collapse
Affiliation(s)
- Ioannis Kontes
- Department of Vascular Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| | - Vangelis Bontinis
- Department of Vascular Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| | - Alkis Bontinis
- Department of Vascular Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| | - Vasiliki Manaki
- Department of Vascular Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| | - Angeliki Chorti
- Department of Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| | - Argyrios Giannopoulos
- Department of Vascular Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| | - Kyriakos Ktenidis
- Department of Vascular Surgery, AHEPA (American Hellenic Educational and Progressive Association) University General Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC
| |
Collapse
|
4
|
Basra M, Hussain P, Li M, Kulkarni S, Stather PW, Armon M, Choksy S. Factors Related to Limb Occlusion After Endovascular Abdominal Aortic Aneurysm Repair (EVAR). Ann Vasc Surg 2024; 99:312-319. [PMID: 37858668 DOI: 10.1016/j.avsg.2023.08.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/03/2023] [Accepted: 08/25/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND Limb occlusion is a potentially serious consequence of endovascular abdominal aortic aneurysm (EVAR). This case-control study identifies factors that predispose to limb occlusion. METHODS A consecutive series of patients from 2 centers undergoing EVAR over an 11-year period 2007-2017 were identified retrospectively. Patient records were interrogated allowing collations of demographics, intraoperative and perioperative data and surveillance data. The preoperative computed tomography angiogram was analyzed to determine EVAR relevant anatomical data. The primary outcome was occlusion of the iliac limb of the implanted EVAR. Raw data are presented as percentages, with comparative data analyzed using Mann-Whitney U-test and binomial logistic regression. RESULTS A total of 787 patients (702 males; median age 78 years, range 53-94 years old) were analyzed. Fifty patients reached the primary outcome, resulting in an overall limb occlusion rate of 6.35%. Factors predictive of limb occlusion were oversizing by >10% native vessel diameter, with oversizing of >20% in 50% of those that occluded. External iliac artery landing zone (12/50 limb occlusions) 24% and postoperative kinking (5/50 limb occlusions) 10% were also more common in those that occluded. Fifty randomly selected controls with similar baseline characteristics were studied. Oversizing of the iliac endograft was found to be significantly greater in the limb occlusion group compared to the controls (P < 0.001) which remained significant on regression analysis. There was no correlation with iliac tortuosity. The Cook stent graft had a 9% limb occlusion rate across sites. Medtronic and Vascutek endografts had 2.4% and 2.5% limb occlusion rates respectively. CONCLUSIONS Oversizing of iliac limbs by >20% could be a contributing factor to limb occlusion after EVAR and judicious oversizing should be used.
Collapse
Affiliation(s)
- Melvinder Basra
- Vascular Surgery Department, Colchester University Hospital Foundation Trust, Colchester, UK; Vascular Surgery Department, Norfolk and Norwich University Hospital, Norwich, UK.
| | - Parvez Hussain
- Vascular Surgery Department, Colchester University Hospital Foundation Trust, Colchester, UK
| | - Mimi Li
- Vascular Surgery Department, Norfolk and Norwich University Hospital, Norwich, UK
| | - Shreya Kulkarni
- Vascular Surgery Department, Norfolk and Norwich University Hospital, Norwich, UK
| | - Philip W Stather
- Vascular Surgery Department, Norfolk and Norwich University Hospital, Norwich, UK; Norwich Medical School, University of East Anglia, Norwich, UK
| | - Matthew Armon
- Vascular Surgery Department, Norfolk and Norwich University Hospital, Norwich, UK
| | - Sohail Choksy
- Vascular Surgery Department, Colchester University Hospital Foundation Trust, Colchester, UK
| |
Collapse
|
5
|
Wanhainen A, Van Herzeele I, Bastos Goncalves F, Bellmunt Montoya S, Berard X, Boyle JR, D'Oria M, Prendes CF, Karkos CD, Kazimierczak A, Koelemay MJW, Kölbel T, Mani K, Melissano G, Powell JT, Trimarchi S, Tsilimparis N, Antoniou GA, Björck M, Coscas R, Dias NV, Kolh P, Lepidi S, Mees BME, Resch TA, Ricco JB, Tulamo R, Twine CP, Branzan D, Cheng SWK, Dalman RL, Dick F, Golledge J, Haulon S, van Herwaarden JA, Ilic NS, Jawien A, Mastracci TM, Oderich GS, Verzini F, Yeung KK. Editor's Choice -- European Society for Vascular Surgery (ESVS) 2024 Clinical Practice Guidelines on the Management of Abdominal Aorto-Iliac Artery Aneurysms. Eur J Vasc Endovasc Surg 2024; 67:192-331. [PMID: 38307694 DOI: 10.1016/j.ejvs.2023.11.002] [Citation(s) in RCA: 90] [Impact Index Per Article: 90.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 09/20/2023] [Indexed: 02/04/2024]
Abstract
OBJECTIVE The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.
Collapse
|
6
|
Van Gerwen A, Gallala S, Kerselaers L, Aerden D, Debing E. Stentgraft Limb Occlusion After Endovascular Aneurysm Repair: Incidence and Risk Factors. Vasc Endovascular Surg 2024; 58:34-41. [PMID: 37400356 DOI: 10.1177/15385744231186276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/05/2023]
Abstract
INTRODUCTION Stentgraft limb occlusion (SLO) is a potential complication of endovascular aneurysm repair (EVAR). The purposes of this single centre study are to report the incidence of SLO after EVAR and to detect possible risk factors. METHODS All patients who underwent EVAR between June 2001 and February 2020 were included in this retrospective study. Demographic data, cardiovascular risk factors, aneurysm characteristics, arterial anatomy, repair strategy, systemic and stentgraft-related complications, and in-hospital and late mortality were collected. Routine follow-up included duplex examination and/or CT angiography at 3 months, 12 months and annually thereafter. Logistic regression analysis was performed to detect predictors for SLO. RESULTS A total of 221 patients (425 stentgraft limbs) were included; of whom 11 patients (5.0%) occluded. Median time to occlusion was 3.3 months and most of the patients presented ischemic signs. Two risk factors for SLO could be identified: symptomatic aneurysm (P .015, odds ratio 4.62, 95% confidence interval 1.35-15.86) and length of the infrarenal abdominal aortic aneurysm (AAA) (P .021, odds ratio 1.31, 95% confidence interval 1.04 - 1.64). CONCLUSION The incidence of SLO after EVAR is low, and most occlusions occur within the first year. Predictors for SLO are the symptomatic aneurysm and the length of the infrarenal AAA. Further research is necessary to pool all predictors and to assess the clinical impact of different follow-up strategies for high-vs low-risk patients.
Collapse
Affiliation(s)
- Anouk Van Gerwen
- Department of Vascular Surgery, Universitair Ziekenhuis Brussel, Brussel, Belgium
| | - Sarah Gallala
- Department of Vascular Surgery, Universitair Ziekenhuis Brussel, Brussel, Belgium
| | - Laura Kerselaers
- Department of Vascular Surgery, Universitair Ziekenhuis Brussel, Brussel, Belgium
| | - Dimitri Aerden
- Department of Vascular Surgery, Universitair Ziekenhuis Brussel, Brussel, Belgium
| | - Erik Debing
- Department of Vascular Surgery, Universitair Ziekenhuis Brussel, Brussel, Belgium
| |
Collapse
|
7
|
González Canga C, Alonso Pastor A, Zanabili Al-Sibbai A, Vaquero Lorenzo F, Álvarez Marcos F, Alonso Pérez M. Aneurysm Sac Shrinkage After EVAR Can Lead to Complications: A Case Report of Complete Endograft Thrombosis Due to Kinking. Vasc Endovascular Surg 2024; 58:105-109. [PMID: 37437582 DOI: 10.1177/15385744231189019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/14/2023]
Abstract
BACKGROUND Bilateral limb occlusion after endovascular repair of abdominal aortic aneurysms (EVAR) is an uncommon entity. The relationship between graft kinking and unilateral limb occlusion is widely described in the literature. Our aim is to report a case of complete endograft thrombosis due to bilateral limb kinking secondary to aneurysm sac shrinkage, treated by endovascular means. CASE REPORT A 67 year-old male with history of EVAR with an Incraft® endograft (Cordis, Bridgewater, NJ, USA) four years before, presented at the emergency department with disabling claudication of the right lower extremity and a better tolerated 10-month left extremity claudication. Complete endograft thrombosis with bilateral limb kinking and a remarkable reduction of the aneurysm sac was observed in the computed tomography angiography. An endovascular repair was performed, through bilateral open femoral access and with angiographic control through percutaneous left brachial access. Bilateral recanalization was achieved and the endograft was re-lined with two 10x150 mm Viabahn (WL Gore & Ass., Flagstaff, AZ, USA). Both sides were extended with a 11 × 50 mm Viabahn (WL Gore & Ass., Flagstaff, AZ, USA). The final angiographic control showed bilateral patency with no residual stenosis and the patient recovered distal pulses. Follow-up showed complete patency and no complications at 17 months. CONCLUSIONS Bilateral limb occlusion is a rare complication with technically challenging treatment options. Aneurysm sac shrinkage can affect the endograft configuration, leading to limb distortion and occasionally to bilateral limb occlusion after EVAR. Special attention should be put on imaging follow-up to detect these complications before occlusion occurs.
Collapse
Affiliation(s)
- Carmen González Canga
- Department of Vascular Surgery, Asturias University Central Hospital (HUCA), Oviedo, Spain
| | - Alba Alonso Pastor
- Department of Vascular Surgery, Asturias University Central Hospital (HUCA), Oviedo, Spain
| | | | | | - Francisco Álvarez Marcos
- Department of Vascular Surgery, Asturias University Central Hospital (HUCA), Oviedo, Spain
- Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain
| | - Manuel Alonso Pérez
- Department of Vascular Surgery, Asturias University Central Hospital (HUCA), Oviedo, Spain
- Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain
| |
Collapse
|
8
|
Mirgolbabaee H, van de Velde L, Geelkerken RH, Versluis M, Groot Jebbink E, Reijnen MMPJ. Ultrasound Particle Image Velocimetry to Investigate Potential Hemodynamic Causes of Limb Thrombosis After Endovascular Aneurysm Repair With the Anaconda Device. J Endovasc Ther 2023:15266028231219988. [PMID: 38149463 DOI: 10.1177/15266028231219988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2023]
Abstract
PURPOSE To identify potential hemodynamic predictors for limb thrombosis (LT) following endovascular aneurysm repair with the Anaconda endograft in a patient-specific phantom. MATERIALS AND METHODS A thin-walled flow phantom, based on a patient's aortic anatomy and treated with an Anaconda endograft, that presented with a left-sided LT was fabricated. Contrast-enhanced ultrasound particle image velocimetry was performed to quantify time-resolved velocity fields. Measurements were performed in the same phantom with and without the Anaconda endograft, to investigate the impact of the endograft on the local flow fields. Hemodynamic parameters, namely vector complexity (VC) and residence time (RT), were calculated for both iliac arteries. RESULTS In both limbs, the vector fields were mostly unidirectional during the peak systolic and end-systolic velocity phases before and after endograft placement. Local vortical structures and complex flow fields were observed at the diastolic and transitional flow phases. The average VC was higher (0.11) in the phantom with endograft, compared to the phantom without endograft (0.05). Notably, in both left and right iliac arteries, the anterior wall regions corresponded to a 2- and 4-fold increase in VC in the phantom with endograft, respectively. RT simulations showed values of 1.3 to 6 seconds in the phantom without endograft. A higher RT (up to 25 seconds) was observed in the phantom with endograft, in which the left iliac artery, with LT in follow-up, showed 2 fluid stasis regions. CONCLUSION This in vitro study shows that unfavorable hemodynamics were present mostly in the limb that thrombosed during follow-up, with the highest VC and longest RT. These parameters might be valuable in predicting the occurrence of LT in the future. CLINICAL IMPACT This in-vitro study aimed to identify potential hemodynamic predictors for limb thrombosis following EVAR using ultrasound particle image velocimetry (echoPIV) technique. It was shown that unfavorable hemodynamic norms were present mostly in the thrombosed limb. Owing to the in-vivo feasibility of the echoPIV, future efforts should focus on the evaluation of these hemodynamic norms in clinical trials. Thereafter, using echoPIV as a bedside technique in hospitals becomes more promising. Performing echoPIV in pre-op phase may provide valuable insights for surgeons to enhance treatment planning. EchoPIV is also applicable for follow-up sessions to evaluate treatment progress and avoid/predict complications.
Collapse
Affiliation(s)
- Hadi Mirgolbabaee
- Multi-Modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Physics of Fluids Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Lennart van de Velde
- Multi-Modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Physics of Fluids Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| | - Robert H Geelkerken
- Multi-Modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Section of Vascular Surgery, Department of Surgery, Medisch Spectrum Twente, Enschede, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Erik Groot Jebbink
- Multi-Modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| | - Michel M P J Reijnen
- Multi-Modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| |
Collapse
|
9
|
Simmering JA, de Vries M, Haalboom M, Reijnen MMPJ, Slump CH, Geelkerken RH. Geometrical Changes of the Aorta as Predictors for Thromboembolic Events After EVAR With the Anaconda Stent-Graft. J Endovasc Ther 2023; 30:904-919. [PMID: 35786215 PMCID: PMC10637097 DOI: 10.1177/15266028221105839] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE Thromboembolic events (TE), including limb graft occlusion (LGO) and distal limb embolization (DLE), are common complications after endovascular aneurysm repair (EVAR). The aim of this study was to find predictors for TE in patients treated with the Anaconda stent-graft for infrarenal aneurysms. MATERIALS AND METHODS Geometrical and anatomical variables were retrospectively analyzed in a consecutive Anaconda cohort. Pre- and postoperative CT scans were used to derive geometrical parameters length, curvature, torsion, and tortuosity index (TI) from the center lumen lines (CLLs). Limb characteristics, pre-to-post EVAR and mid-term-follow-up changes in the parameters were evaluated for their predictive value for TE. RESULTS Eighty-four patients (mean age 74±8.3 years, 74 men) were enrolled. The risk of TE was lowered with pre-to-post implant decreasing TI (steps of 0.05: OR: 1.30, 95% CI: 1.01-1.66, p=0.04), pre-to-post implant decreasing mean curvature (OR: 1.08, 95% CI: 1.01-1.16, p=0.03), and a larger degree of circumferential common iliac artery (CIA) calcification (OR: 0.98, 95% CI: 0.97-1.00, p=0.03). The only LGO predictor was the caudal relocation of maximal curvature after EVAR (OR: 1.01, 95% CI: 1.00-1.01, p=0.04). Preventors of DLE were CIA diameter (OR: 0.87, 95% CI: 0.76-0.99, p=0.04), circumferential CIA calcification (OR: 0.97, 95% CI: 0.95-1.00, p=0.03), mean and maximal curvature of the preoperative aortoiliac trajectory (OR: 0.86, 95% CI: 0.79-0.94, p<0.01 and OR: 0.97, 95% CI: 0.95-1.00, p=0.03, respectively) and pre-to-postoperative decrease in mean curvature (OR: 1.11, 95% CI: 1.02-1.21, p=0.02). Midterm TE predictors were length (OR: 0.95, 95% CI: 0.89-1.01, p=0.08) and torsion maximum location (OR: 1.01, 95% CI: 0.99-1.01, p=0.10). CONCLUSION The present study confirms that treatment of infrarenal AAA with an Anaconda stent-graft is related to a relatively high TE rate which decreases with a pre-to-postoperative reduction in curvature and TI, and a larger degree of circumferential CIA calcification. In other words, more aortoiliac straightening and more circumferential CIA calcification may prevent TE development after EVAR with this stent-graft.
Collapse
Affiliation(s)
- Jaimy A. Simmering
- Division of Vascular Surgery, Department of Surgery, Medisch Spectrum Twente, Enschede, The Netherlands
- Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Mattijs de Vries
- Division of Vascular Surgery, Department of Surgery, Diakonessenhuis Utrecht, Utrecht, The Netherlands
| | - Marieke Haalboom
- Medical School Twente, Medisch Spectrum Twente, Enschede, The Netherlands
| | - Michel M. P. J. Reijnen
- Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Division of Vascular Surgery, Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| | - Cornelis H. Slump
- Robotics and Mechatronics (RaM) Group, Faculty of Electrical Engineering, Mathematics and Computer Science, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Robert H. Geelkerken
- Division of Vascular Surgery, Department of Surgery, Medisch Spectrum Twente, Enschede, The Netherlands
- Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| |
Collapse
|
10
|
Ogino H, Iida O, Akutsu K, Chiba Y, Hayashi H, Ishibashi-Ueda H, Kaji S, Kato M, Komori K, Matsuda H, Minatoya K, Morisaki H, Ohki T, Saiki Y, Shigematsu K, Shiiya N, Shimizu H, Azuma N, Higami H, Ichihashi S, Iwahashi T, Kamiya K, Katsumata T, Kawaharada N, Kinoshita Y, Matsumoto T, Miyamoto S, Morisaki T, Morota T, Nanto K, Nishibe T, Okada K, Orihashi K, Tazaki J, Toma M, Tsukube T, Uchida K, Ueda T, Usui A, Yamanaka K, Yamauchi H, Yoshioka K, Kimura T, Miyata T, Okita Y, Ono M, Ueda Y. JCS/JSCVS/JATS/JSVS 2020 Guideline on Diagnosis and Treatment of Aortic Aneurysm and Aortic Dissection. Circ J 2023; 87:1410-1621. [PMID: 37661428 DOI: 10.1253/circj.cj-22-0794] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Affiliation(s)
- Hitoshi Ogino
- Department of Cardiovascular Surgery, Tokyo Medical University
| | - Osamu Iida
- Cardiovascular Center, Kansai Rosai Hospital
| | - Koichi Akutsu
- Cardiovascular Medicine, Nippon Medical School Hospital
| | - Yoshiro Chiba
- Department of Cardiology, Mito Saiseikai General Hospital
| | | | | | - Shuichiro Kaji
- Department of Cardiovascular Medicine, Kansai Electric Power Hospital
| | - Masaaki Kato
- Department of Cardiovascular Surgery, Morinomiya Hospital
| | - Kimihiro Komori
- Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine
| | - Hitoshi Matsuda
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Kenji Minatoya
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University
| | | | - Takao Ohki
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine
| | - Yoshikatsu Saiki
- Division of Cardiovascular Surgery, Graduate School of Medicine, Tohoku University
| | - Kunihiro Shigematsu
- Department of Vascular Surgery, International University of Health and Welfare Mita Hospital
| | - Norihiko Shiiya
- First Department of Surgery, Hamamatsu University School of Medicine
| | | | - Nobuyoshi Azuma
- Department of Vascular Surgery, Asahikawa Medical University
| | - Hirooki Higami
- Department of Cardiology, Japanese Red Cross Otsu Hospital
| | | | - Toru Iwahashi
- Department of Cardiovascular Surgery, Tokyo Medical University
| | - Kentaro Kamiya
- Department of Cardiovascular Surgery, Tokyo Medical University
| | - Takahiro Katsumata
- Department of Thoracic and Cardiovascular Surgery, Osaka Medical College
| | - Nobuyoshi Kawaharada
- Department of Cardiovascular Surgery, Sapporo Medical University School of Medicine
| | | | - Takuya Matsumoto
- Department of Vascular Surgery, International University of Health and Welfare
| | | | - Takayuki Morisaki
- Department of General Medicine, IMSUT Hospital, the Institute of Medical Science, the University of Tokyo
| | - Tetsuro Morota
- Department of Cardiovascular Surgery, Nippon Medical School Hospital
| | | | - Toshiya Nishibe
- Department of Cardiovascular Surgery, Tokyo Medical University
| | - Kenji Okada
- Department of Surgery, Division of Cardiovascular Surgery, Kobe University Graduate School of Medicine
| | | | - Junichi Tazaki
- Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University
| | - Masanao Toma
- Department of Cardiology, Hyogo Prefectural Amagasaki General Medical Center
| | - Takuro Tsukube
- Department of Cardiovascular Surgery, Japanese Red Cross Kobe Hospital
| | - Keiji Uchida
- Cardiovascular Center, Yokohama City University Medical Center
| | - Tatsuo Ueda
- Department of Radiology, Nippon Medical School
| | - Akihiko Usui
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine
| | - Kazuo Yamanaka
- Cardiovascular Center, Nara Prefecture General Medical Center
| | - Haruo Yamauchi
- Department of Cardiac Surgery, The University of Tokyo Hospital
| | | | - Takeshi Kimura
- Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University
| | | | - Yutaka Okita
- Department of Surgery, Division of Cardiovascular Surgery, Kobe University Graduate School of Medicine
| | - Minoru Ono
- Department of Cardiac Surgery, Graduate School of Medicine, The University of Tokyo
| | | |
Collapse
|
11
|
Spath P, Pasqui E, Angiletta D, Spinazzola A, Chegai F, Isernia G, Lepidi S, Silingardi R, de Donato G, Gargiulo M. Penumbra Indigo Percutaneous Aspiration Thrombectomy System in the treatment of Aortic Endograft Iliac Limb Occlusion: Results from an Italian Multicentre Registry. Eur J Vasc Endovasc Surg 2023; 66:77-84. [PMID: 37084878 DOI: 10.1016/j.ejvs.2023.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/12/2023] [Accepted: 04/12/2023] [Indexed: 04/23/2023]
Abstract
OBJECTIVE This study aimed to evaluate the safety and effectiveness of the Penumbra Indigo percutaneous aspiration thrombectomy (PAT) system in the clinical presentation of iliac limb occlusion (ILO) after endovascular aortic repair (EVAR). METHODS A retrospective, observational, multicentre study conducted in eight Italian vascular centres. Consecutive patients presenting with ILO after EVAR were eligible. To assess vessel revascularisation, Thrombo-aspiration In Peripheral Ischaemia (TIPI) classification (score 0-3) was used at presentation (t1), after PAT (t2), and after adjunctive procedures (t3). Successful revascularisation was considered TIPI 2-3 (near complete or complete). Primary intra-operative outcomes were technical success (TS) of Indigo PAT and combined TS of PAT associated with adjunctive procedures when needed. Primary follow up outcomes were safety and effectiveness at one, six, and 12 months. RESULTS From September 2019 to December 2021, there were 48 ILO and 17 patients (35%) [median age 75 years, IQR 71, 83 years; male, 14 (82%); urgent, 8 (47%)] were treated and enrolled. The median time after primary EVAR was 24 months (IQR 0, 42 months). The median clot age from ILO diagnosis to PAT was three days (IQR 1, 12 days). Ten patients (59%) presented with limb threatening ischaemia. At t1, TIPI 0 and 1 was present in 13 (76%) and four (24%) cases, respectively. At t2, primary TS (TIPI 2-3) was achieved in 14 cases (82%) after Indigo PAT (p < .001). Fifteen patients (88%) required adjunctive procedures (14 re-linings, one surgical patch angioplasty). At t3, combined TS was achieved in 16 cases (94%). Intra-operative complication included one (6%) distal embolisation, treated successfully. The 30 day mortality was one case (6%) due to pneumonia. At one, six, and 12 months, clinical success was 100% without ILO recurrence. The median follow up was 23 months (IQR 11, 41 months): at 18 months, survival and freedom from re-intervention were 91 ± 8% and 90 ± 9%, respectively. CONCLUSION This study reports for the first time the efficacy and safety of Penumbra Indigo PAT for ILO after EVAR, with promising technical and clinical success up to one year.
Collapse
Affiliation(s)
- Paolo Spath
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Department of Vascular Surgery, Hospital "Infermi" Rimini, AUSL Romagna, Rimini, Italy.
| | - Edoardo Pasqui
- Vascular Surgery, University of Siena, DSMCN, Siena, Italy
| | | | - Angelo Spinazzola
- Interventional Radiology, Unit of Radiology, ASST-Crema, Crema, Italy
| | - Fabrizio Chegai
- Vascular and Interventional Radiology, Unit of Radiology, Hospital Viterbo, Viterbo, Italy
| | - Giacomo Isernia
- Department of Vascular and Endovascular Surgery, University of Perugia, Perugia, Italy
| | - Sandro Lepidi
- Department of Vascular Surgery, University Hospital of Trieste, Trieste, Italy
| | - Roberto Silingardi
- Department Vascular Surgery of Modena, University of Modena and Reggio Emilia, Modena, Italy
| | | | - Mauro Gargiulo
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Bologna Metropolitan Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria S. Orsola, Bologna, Italy
| |
Collapse
|
12
|
Sulzer T, Tenorio ER, Mesnard T, Vacirca A, Baghbani-Oskouei A, de Bruin JL, Verhagen HJM, Oderich GS. Intraoperative complications during standard and complex endovascular aortic repair. Semin Vasc Surg 2023; 36:189-201. [PMID: 37330233 DOI: 10.1053/j.semvascsurg.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/30/2023] [Accepted: 04/04/2023] [Indexed: 06/19/2023]
Abstract
This study aimed to provide a comprehensive overview of the most common intraoperative adverse events that occur during standard endovascular repair and fenestrated-branched endovascular repair to treat abdominal aortic aneurysms, thoracoabdominal aortic aneurysms, and aortic arch aneurysms. Despite advancements in endovascular techniques, sophisticated imaging and improved graft designs, intraoperative difficulties still occur, even in highly standardized procedures and high-volume centers. This study emphasized that with the increased adoption and complexity of endovascular aortic procedures, strategies to minimize intraoperative adverse events should be protocolized and standardized. There is a need for robust evidence on this topic, which could potentially optimize treatment outcomes and durability of the available techniques.
Collapse
Affiliation(s)
- Titia Sulzer
- The University of Texas Health Science Center at Houston, Houston, TX 77030; Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands.
| | - Emanuel R Tenorio
- The University of Texas Health Science Center at Houston, Houston, TX 77030
| | - Thomas Mesnard
- The University of Texas Health Science Center at Houston, Houston, TX 77030
| | - Andrea Vacirca
- The University of Texas Health Science Center at Houston, Houston, TX 77030
| | | | - Jorg L de Bruin
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Hence J M Verhagen
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Gustavo S Oderich
- The University of Texas Health Science Center at Houston, Houston, TX 77030
| |
Collapse
|
13
|
Chacko P, Hans SS, Nahirniak P, Morton K. Clinical Patterns, Predictors, and Results of Graft Limb Occlusion Following Endovascular Aneurysm Repair. Ann Vasc Surg 2023:S0890-5096(23)00114-0. [PMID: 36918093 DOI: 10.1016/j.avsg.2023.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/02/2023] [Accepted: 02/03/2023] [Indexed: 03/13/2023]
Abstract
OBJECTIVE To assess the incidence, clinical patterns, and outcomes of graft limb occlusion (GLO) following endovascular aneurysm repair (EVAR). METHODS A retrospective study of patients undergoing EVAR from 2002-2017 at two mid-sized suburban teaching hospitals. The ipsilateral and contralateral aorto-common iliac artery angle (A-CIA) and common iliac-external iliac artery angle (CIA-EIA) was determined. The diameter of the EIA, graft extension to the EIA, and prior CIA stenting was recorded. RESULTS Of the 373 patients who underwent EVAR, 319 were analyzed. 22 patients had 23 limbs with GLO (21 unilateral and one bilateral) with a mean follow up of 9.1 +/- 2.1 years. There were no statistically significant differences in mean age, gender, size of the abdominal aortic aneurysm, and risk factors of hypertension, coronary artery disease, diabetes mellitus, and chronic obstructive pulmonary disease in patients with and without GLO. There was no statistically significant difference in A-CIA and CIA-EIA angles. A smaller diameter EIA (6mm or less), graft extension to EIA, and prior CIA stenting were significant predictors of GLO. Four limbs had GLO within one month of EVAR, only open thrombectomy was performed in 2 limbs, open thrombectomy with simultaneous axillo-femoral graft in one limb, and open thrombectomy with self-expandable stent placement in one limb. 12 limbs had GLO within 1-12 months treated with only open thrombectomy in three limbs, open thrombectomy with fasciotomy in one limb, open thrombectomy with graft extension to EIA in one limb, and crossover femoral-femoral graft performed in three limbs. Seven limbs had GLO within 1-5 years with a crossover femoral-femoral graft performed in four limbs and open thrombectomy with graft extension to EIA was performed in one limb. Six limbs with GLO following EVAR did not undergo any intervention. One patient had an above the knee amputation 3 years following occlusion of the axillo-femoral graft and one patient returned in 4 years with an increase in size of the excluded aneurysm leading to acute rupture and death. CONCLUSIONS Graft limb occlusion leads to significant morbidity and mortality following EVAR. Predictors of GLO following EVAR include a small diameter EIA, prior CIA stenting and graft limb extension to the EIA.
Collapse
|
14
|
Evaluation of factors associated with limb thrombus formation after endovascular aortic aneurysm repair. J Vasc Surg 2023; 77:440-445. [PMID: 36252827 DOI: 10.1016/j.jvs.2022.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/03/2022] [Accepted: 10/06/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Limb thrombus formation is a complication that can occur after endovascular aortic repair (EVAR), and its clinical significance has continued to be debated. Our objective was to report the incidence of limb thrombus after EVAR and determine the association of specific demographic, anatomic, and/or graft variables. METHODS A retrospective analysis of EVAR patients at a single tertiary center between January 2010 and December 2018 was performed to determine the limb thrombus rate. Demographic, graft, and anatomic variables were analyzed for an association with limb thrombus. RESULTS A total of 301 patients were included. The average follow-up was 27.6 ± 4.9 months. The mean age was 76.5 ± 0.5 years, and 85% were men. Limb thrombus occurred in 22 patients (7.3%). Of these 22 patients, 11 (50.0%) had had occlusive limb thrombus, 14 (63.6%) were symptomatic, and 17 (77.3%) had required intervention. The patients with limb thrombus were younger (69.8 ± 1.3 years vs 77.1 ± 0.5 years; P < .0001) and more likely to be smokers (10.2% vs 5.2%; P = .10). The incidence of limb thrombus with the Alpha graft (10.7%; Cook Medical Inc, Bloomington, IN) was compared with that with non-Cook grafts (4.0%; P = .07). The average common iliac artery diameter for patients with and without limb thrombus was 14.1 mm and 16.1 mm, respectively (P < .01). Right-sided limb thrombus was more likely in smaller right iliac arteries (14.7 ± 0.9 cm vs 17.0 ± 0.6 cm; P < .05), with a similar finding on the left (13.6 ± 0.9 cm vs 15.2 ± 0.4 cm; P = .13). Unilateral limb thrombus was almost twice as likely on the main body side than on the contralateral side (11 vs 6). Limb thrombus was not associated with aortoiliac disease (odds ratio [OR], 1.31; 95% confidence interval [CI], 0.37-4.62), limb extension (OR, 0.47; 95% CI, 0.06-3.62), or nonmatching limb heights (OR, 1.36; 95% CI, 0.54-3.43). Limb thrombus was also not associated with increased 30-day mortality (P > .05). CONCLUSIONS Limb thrombus formation is a complication that can occur after EVAR (7.3%). In our study, limb thrombus was seen more frequently in younger patients and those who smoked. Cook Alpha grafts had a thrombus formation rate of 10.7%, which was not significantly higher than that with other brands. Limb thrombus was more likely in smaller iliac arteries and on the main body side.
Collapse
|
15
|
Wen W, Mufty H, Katsargyris A, Maleux G, Daenens K, Houthoofd S, Fourneau I, Verhoeven E. The influence of narrow aortic bifurcation on limb graft patency: a two-center retrospective study. THE JOURNAL OF CARDIOVASCULAR SURGERY 2022; 63:708-715. [PMID: 35913034 DOI: 10.23736/s0021-9509.22.12007-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND Narrow aortic bifurcation (NAB) has been considered as a potential risk factor for graft limb thrombosis after endovascular aortic repair (EVAR). The aim of this study was to compare mid- and long-term outcome of EVAR in patients with NAB and standard aortic bifurcation (SAB). METHODS Data from patients receiving EVAR were prospectively collected and retrospectively analyzed. In case of angiographic limb stenosis (>50%), additional stenting was performed. Patients with a NAB (≤20mm) were included in the NAB group, the remaining patients in the SAB group. Primary endpoints were limb thrombosis rate and technical success. RESULTS A total of 902 patients were included; 18.3% (N.=165/902) in the NAB and 81.7% (N.=737/902) in the SAB group. Mean follow-up time was 43 months (range 0-198 months). Bilateral stenting of the aortic bifurcation was performed in 2.7% (N.=27/902), 8.5% (N.=14/165) in the NAB and 1.4% (N.=10/737) in the SAB group (P=0.001). Limb thrombosis was found in 2.8% (N.=25/902), 3.6% (N.=6/165) in the NAB and 2.6% (N.=19/737) in the SAB group (P=0.55). Technical success was 97.8%, 98.8% in the NAB and 97.6% in the SAB group (P=0.33). Device related reintervention rate was 16% (N.=144/902), 15.2% in the NAB and 16.1% in the SAB group (P=0.75). CONCLUSIONS Standard EVAR could safely be performed in patients with NAB (≤20mm) when a low threshold for additional stenting was applied. This resulted in no significant higher incidence of limb thrombosis. Additional stent deployment did not increase the complication rate.
Collapse
Affiliation(s)
- Wen Wen
- Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium -
| | - Hozan Mufty
- Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, General Hospital and Paracelsus Medical University, Nuremberg, Germany
| | - Geert Maleux
- Department of Radiology, University Hospitals Leuven, Leuven, Belgium
| | - Kim Daenens
- Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Sabrina Houthoofd
- Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Inge Fourneau
- Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Eric Verhoeven
- Department of Vascular and Endovascular Surgery, General Hospital and Paracelsus Medical University, Nuremberg, Germany
| |
Collapse
|
16
|
Kim J, Chun JY, Ameli-Renani S, Ratnam L, Mailli L, Pavlidis V, Das R, Morgan R. Outcome of endovascular treatment of internal iliac artery aneurysms: a single center retrospective review. CVIR Endovasc 2022; 5:53. [PMID: 36255546 PMCID: PMC9579245 DOI: 10.1186/s42155-022-00330-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/11/2022] [Indexed: 11/14/2022] Open
Abstract
PURPOSE To evaluate the technical feasibility and clinical outcomes of endovascular treatment for internal iliac artery (IIA) aneurysms. MATERIAL AND METHODS This was a retrospective analysis of 25 patients with 32 IIA aneurysms (mean diameter: 39.1 ± 12.6 mm) who underwent endovascular treatment over a 10-year period, and were available for follow-up. Univariate analysis was used to determine the association between variables (including aortoiliac involvement and technique) and outcome. RESULTS The IIA inflow was covered with an iliac stent graft (N = 29) or embolized with a plug (N = 3). The IIA outflow was embolized in all but one case in which there was thrombotic occlusion of outflow branches. Outflow embolization using plugs or coils was performed in the distal IIA or anterior/posterior trunks in 9 cases and distal IIA branches in 22 cases. During a mean follow-up period of 39.9 months, 31.2% of aneurysms demonstrated endoleak and 12.5% demonstrated enlargement. Univariate analysis revealed that endoleak was associated with technical failure (p = 0.01) and that endoleak rate was higher in patients who underwent distal IIA branch embolization (p = 0.03). No variable was associated with sac expansion. Major complication occurred in one patient who died from aneurysm rupture. Minor complications were reported in six patients who developed femoral pseudoaneurysm (N = 2, 8%), buttock claudication (N = 3, 12%), and limb graft occlusion (N = 1, 4%). CONCLUSION Endovascular treatment of IIA aneurysms effectively prevents sac expansion. Endoleak was more frequently observed in cases of technical failure and those in which distal IIA branches were embolized. LEVEL OF EVIDENCE Level 3b, retrospective cohort study.
Collapse
Affiliation(s)
- Jinoo Kim
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK ,grid.411261.10000 0004 0648 1036Department of Radiology, Ajou University Hospital, Suwon, Gyeonggi-do Republic of Korea
| | - Joo-Young Chun
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| | - Seyed Ameli-Renani
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| | - Lakshmi Ratnam
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| | - Leto Mailli
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| | - Vyzantios Pavlidis
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| | - Raj Das
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| | - Robert Morgan
- grid.451349.eDepartment of Radiology, St George’s University Hospitals NHS Foundation Trust, Tooting, London, UK
| |
Collapse
|
17
|
Percutaneous Thrombectomy in Patients with Occlusions of the Aortoiliac Segment: A Case Series. Cardiovasc Intervent Radiol 2022; 45:1684-1692. [PMID: 36002537 DOI: 10.1007/s00270-022-03222-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 07/03/2022] [Indexed: 11/02/2022]
Abstract
OBJECTIVE Thrombectomy of the aortoiliac segment remains a challenge for surgical and endovascular revision. This study aimed to evaluate the concept of percutaneous thrombectomy in patients with aortoiliac segment occlusions. MATERIALS & METHODS Eighteen patients with aortoiliac occlusion who underwent percutaneous thrombectomy were retrospectively identified using the local picture archive and divided into the stent-graft (N = 10) and native vessels (N = 8) groups. The procedure was performed by placing a 12-24 French sheath adjacent to the distal end of the occluded vessel segment. The occlusion was passed with a balloon catheter which was retracted after inflation, to deliver the thrombus into the sheath. Technical success (reperfusion of the vessel and no residual thrombus/stenosis < 30%), complications and primary arterial patency were assessed. Follow-up included computed tomography angiography and evaluation of the clinical situation via telephone. RESULTS Technical success was achieved in 38% (7/18) of patients after percutaneous thrombectomy alone and in 100% after additional procedures. The most common complication was peripheral embolism (44%, 8/18), which was treated successfully in all cases and was linked to a mismatch between the sheath and target vessel of ≥ 1 mm (P < .01). There were no significant differences in the incidence of complications between the two groups. Primary patency was 72% (13/18) with no significant difference between groups (P = .94). Follow-up CT scans were available for 13/18 patients (72%), with a mean follow-up time of 270 ± 146 days. All patients were contacted via phone (follow-up time, 653 ± 264 days). CONCLUSION Percutaneous thrombectomy appears to be effective for revascularization of the aortoiliac segment, both in stent-grafts and in native vessels. The most common complication is peripheral embolism; however, the risk may be reduced by choosing an adequate sheath size.
Collapse
|
18
|
Bahroloomi D, Qato K, Nguyen N, Schreiber-Gregory D, Conway AM, Giangola G, Carroccio A. External iliac artery extension causes greater aneurysm sac regression than the bell-bottom technique or iliac branch endoprosthesis for repair of concomitant infrarenal aortic and iliac artery aneurysm. J Vasc Surg 2022; 76:132-140. [PMID: 34998943 DOI: 10.1016/j.jvs.2021.12.062] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 12/13/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVE Aneurysmal extension of abdominal aortic aneurysms (AAAs) to the common iliac artery (CIA) presents a technical challenge to successful endovascular abdominal aortic aneurysm repair (EVAR). In the present study, we compared sac shrinkage and perioperative outcomes after the bell-bottom technique (BBT), internal iliac artery embolization and external iliac artery extension (EIE), and iliac branch endoprosthesis (IBE). METHODS Using the Vascular Quality Initiative database, a retrospective analysis was conducted for patients who had undergone EVAR from 2013 to 2019. The demographic, anatomic, and perioperative data were analyzed. All patients with a proximal aortic neck length <10 mm and aortic graft diameter >32 mm were excluded from the analysis. The patients were subdivided into four groups according to the distal limb strategy: group 1, control group with a bilateral common iliac artery limb <20 mm; group 2, BBT with either a unilateral or bilateral limb >20 mm; group 3, EIE technique; and group 4, IBE. The primary endpoint was the maximal change in the aortic diameter during follow-up. The secondary endpoints included postoperative complications and the rate of endoleak. RESULTS The records for 14,455 patients who had undergone EVAR were queried and 5788 met the anatomic criteria. The average age was 73 years, and 86.3% were men. The maximal change in the aortic diameter in the control, BBT, IBE, and EIE groups was -7.2 mm, -6.1 mm, -4.6 mm, and -6.8 mm, respectively (P = .06). The differences were not statistically significant on univariate analysis at an average follow-up of 405 days. However, on multivariable analysis (P = .01), compared with the control group, the BBT and IBE groups were 18.4% (odds ratio [OR], 0.816; 95% confidence interval [CI], 0.68-0.98) and 48.0% (OR, 0.52; 95% CI, 0.33-0.82) less likely to experience aneurysmal shrinkage, respectively. In contrast, the EIE group showed no significant difference in shrinkage compared with that in the control group. Multivariable analysis of the groups also revealed that compared directly with the BBT group, the EIE group was 69.5% more likely to have experienced shrinkage in the aortic aneurysmal diameter (OR, 1.70; 95% CI, 1.05-2.75). The BBT and IBE groups had a significantly higher rate of type II endoleaks (17.63% and 16.95%, respectively; P = .03). The EIE group had a higher rate of type Ib endoleaks (1.9%) compared with the BBT (1.1%), IBE (1.7%), and control (0.3%) groups (P = .01). No differences were found between the groups in terms of postoperative myocardial infarction (P = .47) or respiratory (P = .61) or intestinal (P = .71) complications. However, the rates of limb complications and reoperation were higher in the EIE group. CONCLUSIONS The present study revealed that the EIE technique was more likely to demonstrate shrinkage in the aortic aneurysmal diameter than were the BBT and IBE groups compared with the control group on multivariable analysis. The EIE technique was also more likely to result in aneurysmal sac shrinkage than was the BBT group, albeit with greater rates of limb-related complications.
Collapse
Affiliation(s)
- Donna Bahroloomi
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY.
| | - Khalil Qato
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY
| | - Nhan Nguyen
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY
| | - Deanna Schreiber-Gregory
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY
| | - Allan M Conway
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY
| | - Gary Giangola
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY
| | - Alfio Carroccio
- Department of General Surgery, Lenox Hill Hospital, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell Health, New York, NY
| |
Collapse
|
19
|
Abstract
PURPOSE OF REVIEW Abdominal aortic aneurysms (AAA) can carry extremely high mortality rates and most will only present with symptoms with impending rupture. We present an overview of management of this disease process starting with screening, to medical management, surveillance and treatment options currently available, as well as those being studied for future use. RECENT FINDINGS Screening has been proven to reduce the mortality rate. There still remains a paucity of data to support medical therapies to help mitigate the rate of aneurysm growth and prevent rupture. However, on the topic of repair, there have been advancements in endovascular devices which have broadened the scope of treatment for patients with anatomy not amenable to standard endovascular repair or those who are not suitable candidates for open surgical repair. Appropriate surveillance, risk factor modification, and operative repair, when indicated, are the cornerstones of contemporary management of AAAs. Advancements in endovascular technologies have allowed us to treat more patients. Further research is warranted on non-operative medical therapies.
Collapse
|
20
|
Gozzo C, Caruana G, Cannella R, Farina A, Giambelluca D, Dinoto E, Vernuccio F, Basile A, Midiri M. CT angiography for the assessment of EVAR complications: a pictorial review. Insights Imaging 2022; 13:5. [PMID: 35032231 PMCID: PMC8761205 DOI: 10.1186/s13244-021-01112-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 10/18/2021] [Indexed: 11/26/2022] Open
Abstract
Endovascular aneurysm repair (EVAR) is a minimally invasive treatment proposed as an alternative to open repair in patients with abdominal aortic aneurysms. EVAR consists in a stent-graft placement within the aorta in order to exclude the aneurysm from arterial circulation and reduce the risk of rupture. Knowledge of the various types of devices is mandatory because some stents/grafts are more frequently associated with complications. CT angiography is the gold standard diagnostic technique for preprocedural planning and postprocedural surveillance. EVAR needs long-term follow-up due to the high rate of complications. Complications can be divided in endograft device-related and systemic complications. The purpose of this article is to review the CT imaging findings of EVAR complications and the key features for the diagnosis.
Collapse
Affiliation(s)
- Cecilia Gozzo
- Radiodiagnostic and Radiotherapy Unit, Department of Medical and Surgical Sciences and Advanced Technologies "GF Ingrassia". Catania, Italy, Via Santa Sofia 78, 95123, Catania, Italy
| | - Giovanni Caruana
- Neuroradiology Section, Department of Radiology (IDI), Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Pg. Vall d'Hebron 119-129, 08035, Barcelona, Spain
| | - Roberto Cannella
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", University of Palermo, Via del Vespro 129, 90127, Palermo, Italy.,Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties (PROMISE), University of Palermo, 90127, Palermo, Italy
| | - Arduino Farina
- Vascular Surgery Unit ARNAS Civico Di Cristina Benfratelli, Palermo, Italy
| | - Dario Giambelluca
- Section of Radiology, Asp Siracusa, Ospedale Umberto I, Via Giuseppe Testaferrata 1, Siracusa, SR, Italy
| | - Ettore Dinoto
- Vascular Surgery Unit AOUP Policlinico 'P. Giaccone', Palermo, Italy
| | - Federica Vernuccio
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", University of Palermo, Via del Vespro 129, 90127, Palermo, Italy.
| | - Antonio Basile
- Radiodiagnostic and Radiotherapy Unit, Department of Medical and Surgical Sciences and Advanced Technologies "GF Ingrassia". Catania, Italy, Via Santa Sofia 78, 95123, Catania, Italy
| | - Massimo Midiri
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", University of Palermo, Via del Vespro 129, 90127, Palermo, Italy
| |
Collapse
|
21
|
ENDOVASCULAR REPAIR OF NARROW DISTAL AORTAS USING AN IN-SITU FENESTRATION TECHNIQUE. J Vasc Interv Radiol 2022; 33:489-494. [DOI: 10.1016/j.jvir.2022.01.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 12/16/2021] [Accepted: 01/19/2022] [Indexed: 11/24/2022] Open
|
22
|
Leeuwerke SJG, de Niet A, Geelkerken RH, Reijnen MMPJ, Zeebregts CJ. Incidence and predictive factors for endograft limb patency of the Fenestrated Anaconda™ endograft used for complex endovascular aneurysm repair. J Vasc Surg 2021; 75:1512-1520.e1. [PMID: 34921964 DOI: 10.1016/j.jvs.2021.11.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Accepted: 11/12/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To describe the incidence, risk factors and outcomes of treatment for limb occlusion in patients treated for complex (thoraco-)abdominal aortic aneurysms (AAA) with the Fenestrated Anaconda™. METHODS Between June 2010 and May 2018, 335 patients underwent elective fenestrated aortic aneurysm repair in 11 participating centers using the Fenestrated Anaconda™ with a median follow-up of 14.3 months (IQR 27.4). The primary outcome measure was freedom-from-limb-occlusion. Secondary outcome measures were freedom-from-limb-related-reintervention, secondary patency, and risk factors associated with limb occlusion. RESULTS Thirty (9.0%) patients presented with limb occlusion during follow-up with freedom-from-limb-occlusion of 98.5%, 91.2%, and 81.7% at 30-days, 1 and 5 years, respectively. In 87% of cases, no obvious cause for limb occlusion was documented. Primary occlusion occurred within 30-days in 36.7% and within 1 year in 80.0%. Twenty-three (6.9%) patients underwent an occlusion-related reintervention; seven (23.3%) patients were treated conservatively. Freedom-from-limb-occlusion-related-reintervention at 30-days, one and five years was 97.8%, 93.2% and 88.6%, respectively. Secondary patency was 91.3% after 1-month and 86.2% after 1 and 5 years, respectively. Female sex (OR 3.27 - 95% CI 1.28 to 8.34, P = .01) was a statistically significant predictor for limb occlusion. A higher percentage of thrombus in the aneurysm sac appeared to be protective for limb occlusion (0% compared to <25%: OR 0.22 - 95% CI 0.07 to 0.63, P = .01; 0% compared to 25-50%: OR 0.20 - 95% CI 0.07 to 0.57, P = .00 and 0% compared to >50%: OR 0.08 - 95% CI 0.02 to 0.38, P = .00), as did iliac angulation (OR 0.99 - 95% CI 0.98 to 1.00, P = .04). CONCLUSION Limb occlusion remains a significant impediment of endograft durability in patients treated with the Fenestrated Anaconda™, especially in female patients. Controversially, a high aneurysmal thrombus load and a high degree of iliac angulation appeared to be protective for limb occlusion, for which no obvious cause could be identified.
Collapse
Affiliation(s)
- S J G Leeuwerke
- Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
| | - A de Niet
- Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - R H Geelkerken
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, the Netherlands; Department of Surgery, Medisch Spectrum Twente, Enschede, the Netherlands
| | - M M P J Reijnen
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, the Netherlands; Department of Surgery, Rijnstate, Arnhem, the Netherlands
| | - C J Zeebregts
- Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | | |
Collapse
|
23
|
Avril S, Gee MW, Hemmler A, Rugonyi S. Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3529. [PMID: 34490740 DOI: 10.1002/cnm.3529] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 08/30/2021] [Indexed: 06/13/2023]
Abstract
Endovascular aortic repair (EVAR) has become the preferred intervention option for aortic aneurysms and dissections. This is because EVAR is much less invasive than the alternative open surgery repair. While in-hospital mortality rates are smaller for EVAR than open repair (1%-2% vs. 3%-5%), the early benefits of EVAR are lost after 3 years due to larger rates of complications in the EVAR group. Clinicians follow instructions for use (IFU) when possible, but are left with personal experience on how to best proceed and what choices to make with respect to stent-graft (SG) model choice, sizing, procedural options, and their implications on long-term outcomes. Computational modeling of SG deployment in EVAR and tissue remodeling after intervention offers an alternative way of testing SG designs in silico, in a personalized way before intervention, to ultimately select the strategies leading to better outcomes. Further, computational modeling can be used in the optimal design of SGs in cases of complex geometries. In this review, we address some of the difficulties and successes associated with computational modeling of EVAR procedures. There is still work to be done in all areas of EVAR in silico modeling, including model validation, before models can be applied in the clinic, but much progress has already been made. Critical to clinical implementation are current efforts focusing on developing fast algorithms that can achieve (near) real-time solutions, as well as ways of dealing with inherent uncertainties related to patient aortic wall degradation on an individualized basis. We are optimistic that EVAR modeling in the clinic will soon become a reality to help clinicians optimize EVAR interventions and ultimately reduce EVAR-associated complications.
Collapse
Affiliation(s)
- Stéphane Avril
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, Saint-Étienne, France
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - André Hemmler
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - Sandra Rugonyi
- Biomedical Engineering Department, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
24
|
A Computational Framework Examining the Mechanical Behaviour of Bare and Polymer-Covered Self-Expanding Laser-Cut Stents. Cardiovasc Eng Technol 2021; 13:466-480. [PMID: 34850370 DOI: 10.1007/s13239-021-00597-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 11/16/2021] [Indexed: 01/22/2023]
Abstract
PURPOSE Polymer covered stents have demonstrated promising clinical outcomes with improved patency rates compared to traditional bare-metal stents. However, little is known on the mechanical implication of stent covering. This study aims to provide insight into the role of a polymeric cover on the biomechanical performance of self-expanding laser-cut stents through a combined experimental-computational approach. METHODS Experimental bench top tests were conducted on bare and covered versions of a commercial stent to evaluate the radial, axial and bending response. In parallel, a computational framework with a novel covering strategy was developed that accurately predicts stent mechanical performance. Different stent geometries and polymer materials were also considered to further improve understanding on covered stent mechanics. RESULTS Results show that stent covering causes increased initial axial stiffness and up to 60% greater radial resistive force at small crimp diameters as the cover folds and self-contacts. The incorporation of a cover allows stent designs without interconnecting struts, thereby providing improved flexibility without compromising radial force. It was also shown that use of a stiffer PET polymeric covering material caused significant alterations to the radial and axial response, with the initial axial stiffness increasing six-fold and the maximum radial resistive force increasing four-fold compared to a PTFE-PU covered stent. CONCLUSION This study demonstrates that stent covering has a substantial effect on the overall stent mechanical performance and highlights the importance of considering the mechanical properties of the combined cover and stent.
Collapse
|
25
|
Bogdanovic M, Stackelberg O, Lindström D, Ersryd S, Andersson M, Roos H, Siika A, Jonsson M, Roy J. Limb Graft Occlusion Following Endovascular Aneurysm Repair for Infrarenal Abdominal Aortic Aneurysm with the Zenith Alpha, Excluder, and Endurant Devices: a Multicentre Cohort Study. Eur J Vasc Endovasc Surg 2021; 62:532-539. [PMID: 34266764 DOI: 10.1016/j.ejvs.2021.05.015] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 03/26/2021] [Accepted: 05/08/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Limb graft occlusion (LGO) is a serious complication after endovascular aneurysm repair (EVAR) and while device development enables treatment of increasingly complex aortic anatomy, little is known about how endograft type affects the risk of occlusion. This observational study aimed to explore the incidence of LGO after EVAR for three major endograft systems. METHODS All patients with standard EVAR as the primary intervention for infrarenal abdominal aortic aneurysm (AAA), between January 2012 and December 2018, at five Swedish vascular surgery centres, were included in this multicentre retrospective cohort study. LGO was defined as a total limb occlusion regardless of symptoms, or a treated significant stenosis. A nested case control (NCC) design with incidence density sampling of 1:3 was used for analysis of potential per-operative and morphological risk factors. Conditional logistic regression was used to estimate multivariable odds ratios (OR) with 95% confidence intervals (CI) RESULTS: A total of 924 patients were included. The majority were male (84%), the mean age was 76 years (± 7.5 SD), and median AAA diameter was 59 mm (IQR 55, 67). Patients were treated with Zenith Alpha (n = 315, ZISL limbs), Excluder (n = 152, PLC/PXC limbs), and Endurant (n = 457, ETLW/ ETEW limbs). During median follow up of 37 months (IQR 21, 62), 55 occlusions occurred (5.9%); 39 with Zenith Alpha (12.4%), one with Excluder (0.7%), and 15 with Endurant (3.3%). In the NCC analysis, the Zenith Alpha device (OR 5.31, 95% CI 1.97 - 14.3), external iliac artery (EIA) landing (OR 5.91, 95% CI 1.30 - 26.7), and EIA diameter < 10 mm (OR 4.99, 95% CI 1.46 - 16.9) were associated with an increased risk of LGO. CONCLUSION Endograft device type is an independent risk factor for LGO after EVAR. Specifically, the Zenith Alpha demonstrated an increased risk of LGO compared with the Endurant and Excluder devices. In addition, a narrow EIA and landing zone in EIA are also risk factors for LGO.
Collapse
Affiliation(s)
- Marko Bogdanovic
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Otto Stackelberg
- Department of Clinical Science and Education, Karolinska Institutet at Södersjukhuset, Stockholm, Sweden; Unit of Cardiovascular and Nutritional Epidemiology, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - David Lindström
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden
| | - Samuel Ersryd
- Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden; Centre for Research and Development, Uppsala University/County Council of Gävleborg, Gävle, Sweden
| | - Manne Andersson
- Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden; Department of Surgery, Division of Vascular Surgery, Ryhov County Hospital, Jönköping, Sweden
| | - Håkan Roos
- Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Surgery, Division of Vascular Surgery, Ryhov County Hospital, Jönköping, Sweden
| | - Antti Siika
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Magnus Jonsson
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden; Department of Vascular Surgery, Karolinska University Hospital, Stockholm, Sweden
| | - Joy Roy
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden; Department of Vascular Surgery, Karolinska University Hospital, Stockholm, Sweden.
| |
Collapse
|
26
|
Kikuchi Y, Ohtani N, Kamiya H. The Potential of AFX Iliac Extension in Abdominal Aortic Aneurysms with High Iliac Tortuosity. Int J Angiol 2021; 31:267-272. [PMID: 36588868 PMCID: PMC9803538 DOI: 10.1055/s-0041-1729736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Recently, endovascular aortic aneurysm repair (EVAR) is the most common surgery for abdominal aortic aneurysm (AAA). However, iliac limb complications of EVAR often cause problems in patients with high iliac tortuosity. There is no difference of rate of iliac limb complication among EVAR devices, such as Excluder, Endurant, and Zenith in high iliac tortuosity. But there has been not reported about AFX. We studied AFX iliac extension as it is the only stent graft with an endoskeletal framework. This study aimed to evaluate the AFX iliac extension patency in a case in vitro and to use it in seven cases of AAA with high iliac tortuosity. The silicon tube inserted in the AFX iliac extension was flexed at 30, 60, 90, and 120 degrees, and the lumen of the iliac extension was monitored using an underwater camera in the circulatory system. During the experiment, the Iwaki Bellows Pump (IWAKI CO., LTD., Tokyo, Japan) produced a pulsating flow. We used this in seven patients with AAA high iliac tortuosity cases between November 2018 and May 2019. If the silicon tube inserted in the AFX iliac extension was flexed at 60 and 120 degrees, the stent protruded into the lumen. However, the graft was dilated at all degrees. All seven patients with AFX iliac extension had no complications and a patent iliac artery. The AFX iliac extension can reduce iliac limb complications in cases of high iliac tortuosity.
Collapse
Affiliation(s)
- Yuta Kikuchi
- Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan,Address for correspondence Yuta Kikuchi, MD Department of Cardiovascular Surgery, Asahikawa Medical University1-1-1 Higashi 2 jo, Midorigaoka, Asahikawa, Hokkaido 078-8510Japan
| | - Norifumi Ohtani
- Department of Cardiovascular Surgery, Sapporo Teishinkai Hospital, Sapporo, Hokkaido, Japan
| | - Hiroyuki Kamiya
- Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| |
Collapse
|
27
|
Marques de Marino P, Ibraheem A, Gafur N, Mufty H, Schubert N, Verhoeven EL, Katsargyris A. Limb Occlusion Rate after EVAR With Individualized Graft Limb Selection and a Liberal Protocol of Primary Relining. Ann Vasc Surg 2021; 75:445-454. [PMID: 33823248 DOI: 10.1016/j.avsg.2021.02.046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/24/2021] [Accepted: 02/25/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND This study analyses limb occlusion rates after endovascular aneurysm repair (EVAR) with a strategy including stent-graft limb selection and liberal primary stenting (relining) in anatomies at higher risk for occlusion with uncovered self-expandable or balloon-expandable stents. METHODS All patients undergoing elective EVAR with a bifurcated stent-graft between January 2010-August 2018 were included. A protocol involving personalized stent-graft selection and liberal primary relining based on preoperative imaging was followed during the whole period. Primary endpoints were technical success and primary limb patency during follow-up. Secondary endpoints included mortality and limb reintervention rates. Risk factors associated to limb patency and reintervention rates were analyzed. RESULTS Six hundred and fifteen patients (548 males; mean age 72.9 ± 9 years) were included. Overall technical success was 98.5% (606/615). One (0.16%) patient died during the first 30 days. Of the 1230 limbs, 96 (8%) were deemed at risk for occlusion in view of the anatomy, and primarily relined in 62 patients. Estimated primary limb patency at 6 months, 1 year and 3 years was 99.5 ± 0.2%, 99.2 ± 0.3% and 98.5 ± 0.5%, respectively. Freedom from limb-related reintervention at 6 months, 1 year and 3 years was 98.1 ± 0.4%, 97.4 ± 0.5% and 95.6 ± 0.7%, respectively. Only one (1%) of the 96 relined limbs occluded during follow-up. No differences were found in terms of patency or freedom from reintervention between limbs at risk that were primary stented and limbs without adjunctive stents. Gore Excluder stent-grafts presented better patency (Breslow P = 0.005) and lower reintervention rates (Breslow P = 0.001) than other devices during follow-up. Peripheral artery disease was also a risk factor for reintervention (Breslow P = 0.015). CONCLUSION Liberal use of primary limb relining in patients with iliac anatomy at higher risk for occlusion appears to be a safe and effective strategy to preserve limb patency after EVAR. Gore Excluder graft limbs present better patency and lower reintervention rates than other stent-graft types.
Collapse
Affiliation(s)
- Pablo Marques de Marino
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Anas Ibraheem
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Nargis Gafur
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Hozan Mufty
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany; Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Niklas Schubert
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Eric L Verhoeven
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, Klinikum Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany.
| |
Collapse
|
28
|
Complications of endo-vascular aortic repair for abdominal aortic aneurysm: A retrospective single-centre experience. Ann Med Surg (Lond) 2021; 64:102219. [PMID: 33850623 PMCID: PMC8039833 DOI: 10.1016/j.amsu.2021.102219] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/05/2021] [Accepted: 03/09/2021] [Indexed: 12/20/2022] Open
Abstract
Background Endovascular aortic repair (EVAR) is obviously less invasive than open aortic repair (OAR) for the treatment of infra-renal abdominal aortic aneurysm (AAA). However, it is not free of complications which can potentially result in severe morbidity or even mortality. The purpose of this study was to share our single-center experience with stent-graft related and systemic complications associated with EVAR. Methods Patients with infra-renal AAA treated by elective and emergency EVAR between March 2014 and November 2020 were retrospectively identified. Demographic data, risk factors, American Society of Anesthesiologists (ASA) score, systemic complications, stent-graft related complications, surgical site complications, 30-day mortality, late EVAR related mortality, estimated blood loss, intensive care unit (ICU) length of stay (LOS), hospital LOS and follow-up durations were collected and analyzed. Results A total of 43 patients underwent EVAR during the period of study. There were 42 males (97.7%) and 1 female (2.3%). The mean age was 68.8 ± 6.2 years. Elective EVAR was performed in 36 (83.7%) and emergency EVAR in 7 (16.3%). Technical success was achieved in 42 patients (100%) with no conversion to OAR. Stent-graft related complications were (21.0%) endoleaks, (2.3%) graft limb occlusion, (0%) graft infection, and (2.3%) rupture-EVAR. Systemic complications were (2.3%) myocardial infarction (MI), (2.3%) stroke, (2.3%) spinal cord injury (SCI), (2.3%) respiratory failure, (19.0%) wound complications, and (2.3%) acute lower limb ischemia (ALI). The 30-day mortality was (2.3%) due to perioperative MI and the late graft related mortality was (2.3%) due to rupture-EVAR. Conclusion EVAR showed a high technical success rate with no conversion to OAR. The most common complications were type II and type I endoleaks followed by graft limb occlusion. The 30-day mortality was 2.3% due to perioperative MI. Only one late stent-graft related mortality was registered due to rupture-EVAR.
Collapse
|
29
|
Ferrer C, Simonte G, Parlani G, Coscarella C, Spataro C, Pupo G, Lenti M, Giudice R. Results of adjunctive stenting with high-radial force stents to prevent or treat limb occlusion after EVAR. THE JOURNAL OF CARDIOVASCULAR SURGERY 2021; 62:250-257. [PMID: 33635040 DOI: 10.23736/s0021-9509.21.11635-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The aim of this study was to report the results of a multicenter experience on the use of adjunctive stents deployed inside abdominal aortic endografts with the purpose to prevent or treat limb occlusion after endovascular aneurysm repair (EVAR). METHODS Between 2010 and 2018, there were 35 patients with aorto-iliac aneurysm presenting one or more risk factors for endograft limb occlusion (narrow aortic bifurcation and/or stenotic, highly angulated or occluded iliac arteries), who were treated with standard bifurcated stent graft reinforced by the means of a single model of balloon-expandable platinum/iridium bare stent (CP Stent; NuMED, Inc., Hopkinton, NY, USA). Technical success, mortality, limb patency and reintervention rate during follow-up were the main endpoints assessed. RESULTS Technical success was 100%. No patients died perioperatively and no major complication was registered. During a mean follow-up of 48 months (range 1-87), neither aortic-related death nor secondary intervention was registered. At a mean follow-up imaging of 39.4 months (range 1-81) no endograft limb lost its patency. CONCLUSIONS The use of high-radial force balloon-expandable stents deployed inside bifurcated endografts to prevent or treat limb occlusion is a safe and effective adjunctive procedure, with outstanding long-term outcomes in terms of patency and reinterventions.
Collapse
Affiliation(s)
- Ciro Ferrer
- Unit of Vascular and Endovascular Surgery, San Giovanni Addolorata Hospital, Rome, Italy -
| | - Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Gianbattista Parlani
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Carlo Coscarella
- Unit of Vascular and Endovascular Surgery, San Giovanni Addolorata Hospital, Rome, Italy
| | - Claudio Spataro
- Unit of Vascular and Endovascular Surgery, San Giovanni Addolorata Hospital, Rome, Italy
| | - Guglielmo Pupo
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Massimo Lenti
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Rocco Giudice
- Unit of Vascular and Endovascular Surgery, San Giovanni Addolorata Hospital, Rome, Italy
| |
Collapse
|
30
|
Dupont C, Kaladji A, Rochette M, Saudreau B, Lucas A, Haigron P. Numerical simulation of fenestrated graft deployment: Anticipation of stent graft and vascular structure adequacy. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e03409. [PMID: 33098246 DOI: 10.1002/cnm.3409] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 10/10/2020] [Accepted: 10/12/2020] [Indexed: 06/11/2023]
Abstract
Fenestrated endovascular aneurism repair (FEVAR) is a minimally invasive technique, and its success depends on the adequacy of the correspondence between the visceral arteries ostia and position of the fenestrations of the stent graft (SG) during its deployment in juxtarenal aneurisms. However, the fenestration position is generally determined from a preoperative computerised tomography (CT) scan, without considering the vascular deformation induced by the insertion of the endovascular tools. Catheterisation difficulties may occur during clinical procedures. Accordingly, the objective of this work is to present an initial proof of concept aimed at anticipating and optimising the position of the fenestrations, while considering the vascular deformation induced by the insertion of the endovascular tools. The proposed method relies on the finite element method to simulate the SG deployment in a vascular structure (VS), and considers the vascular deformation induced by the tools. After determining the optimal simulation parameters for a patient-specific case, the robustness of the method is demonstrated on six other representative anatomies. The simulated SG is also compared with post-deployment CT observations, and demonstrates good adequacy. The results show that the numerically corrected fenestration positions, as determined from the simulated results following the insertion of the endovascular tools, deviate from those of the standard plan (as determined from the preoperative CT scan). This indicates that the SG-VS adequacy could be improved via simulation-based planning, to anticipate potential catheterisation difficulties.
Collapse
Affiliation(s)
- Claire Dupont
- Université de Rennes, CHU Rennes, Inserm, LTSI-UMR 1099, Rennes, France
| | - Adrien Kaladji
- Université de Rennes, CHU Rennes, Inserm, LTSI-UMR 1099, Rennes, France
| | | | | | - Antoine Lucas
- Université de Rennes, CHU Rennes, Inserm, LTSI-UMR 1099, Rennes, France
| | - Pascal Haigron
- Université de Rennes, CHU Rennes, Inserm, LTSI-UMR 1099, Rennes, France
| |
Collapse
|
31
|
Galanakis N, Kontopodis N, Charalambous S, Palioudakis S, Kakisis I, Geroulakos G, Tsetis D, Ioannou CV. Endovascular Aneurysm Repair with Bifurcated Stent Grafts in Patients with Narrow Versus Regular Aortic Bifurcation: Systematic Review and Meta-analysis of Comparative Studies. Ann Vasc Surg 2020; 73:385-396. [PMID: 33373765 DOI: 10.1016/j.avsg.2020.11.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 11/17/2020] [Accepted: 11/19/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Narrow aortic bifurcation (NAB) is considered as a risk factor for endograft limb thrombosis. The purpose of the study was to investigate the effect of narrow aortic bifurcation on outcomes of elective endovascular aneurysm repair (EVAR). METHODS A systematic review that conformed to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was performed. We searched electronic bibliographic databases using a combination of controlled vocabulary (thesaurus) and free-text terms to identify relevant studies comparing outcomes of EVAR in patients with NAB versus those with regular aortic bifurcation. Pooled estimates of dichotomous outcomes were calculated using odds ratio (OR) and those of continuous outcomes using mean difference and 95% confidence interval (CI). To account for expected heterogeneity, the random-effects model was applied for statistical analysis. RESULTS Six observational studies were included, reporting a total of 2,673 patients (412 with NAR and 2,261 with friendly anatomy). Perioperative mortality was similar between the groups (OR 1.14, 95% CI 0.30-4.34, P = 0.85, I2 = 0%). Limb stenosis and kinking requiring additional intraoperative procedures was significantly more common among patients with NAB (OR 3.02, 95% CI 2.16-4.22, P < 0.00001, I2 = 0%). Nevertheless, 30-day reintervention rate was similar between the groups, as was the rate of limb occlusion during follow-up. CONCLUSIONS Available evidence suggests that at the expense of significantly more intraoperative additional procedures, EVAR with bifurcated devices can be safely performed in patients with NAB.
Collapse
Affiliation(s)
- Nikolaos Galanakis
- Interventional Radiology Unit, Department of Medical Imaging, University of Crete, Medical School, Heraklion, Crete, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University of Crete, Medical School, Heraklion, Crete, Greece.
| | - Stavros Charalambous
- Interventional Radiology Unit, Department of Medical Imaging, University of Crete, Medical School, Heraklion, Crete, Greece
| | - Stefanos Palioudakis
- Thoracic Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University of Crete, Medical School, Heraklion, Crete, Greece
| | - Ioannis Kakisis
- Department of Vascular Surgery, "Attikon" University Hospital, National and Kapodistrian University of Athens, Athens, Greece
| | - George Geroulakos
- Department of Vascular Surgery, "Attikon" University Hospital, National and Kapodistrian University of Athens, Athens, Greece
| | - Dimitrios Tsetis
- Interventional Radiology Unit, Department of Medical Imaging, University of Crete, Medical School, Heraklion, Crete, Greece
| | - Christos V Ioannou
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University of Crete, Medical School, Heraklion, Crete, Greece
| |
Collapse
|
32
|
Yazdi SG, Docherty PD, Khanafer A, Jermy M, Kabaliuk N, Geoghegan PH, Williamson P. In-vitro particle image velocimetry assessment of the endovascular haemodynamic features distal of stent-grafts that are associated with development of limb occlusion. J R Soc N Z 2020. [DOI: 10.1080/03036758.2020.1826988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Sina G. Yazdi
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Paul D. Docherty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Adib Khanafer
- Department of Surgery, University of Otago, Christchurch, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Patrick H. Geoghegan
- Department of Biomedical Engineering, School of Life & Health Sciences, Aston University, Birmingham, UK
- Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg, South Africa
| | - Petra Williamson
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
33
|
Becquemin JP, Haupert S, Issam F, Dubar A, Martelloni Y, Jousset Y, Sauguet A. Five Year Patient Outcomes of Endovascular Abdominal Aortic Aneurysm Repair in the ENDURANT France Registry. Eur J Vasc Endovasc Surg 2020; 61:98-105. [PMID: 33004284 DOI: 10.1016/j.ejvs.2020.08.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 08/06/2020] [Accepted: 08/20/2020] [Indexed: 01/01/2023]
Abstract
OBJECTIVE Endovascular repair is the preferred method of treatment for infrarenal abdominal aortic aneurysms with numerous publications from multiple geographic regions showing excellent patient outcomes. Since the original ACE (Anevrysme de l'aorte abdominale: Chirurgie versus Endoprothese) randomised control trial, studies of French specific population have also contributed significantly to the body of evidence in support of endovascular abdominal aortic repair. METHODS In the ENDURANT France registry, 180 patients were consecutively enrolled from 20 French centres starting in 2012. Investigational sites included public and private practice and differing centre volumes to be as representative of real world French experience as possible. The aim of this study was to present the five year outcomes from this registry. RESULTS Instructions for use (IFU) were respected in 97.8% (176/180) of patients. At five years, the Kaplan-Meier overall survival was 69.9% ± 3.5% and the freedom from aneurysm related death was 97.6% ± 1.2%. The freedom from Type IA endoleaks was 94.5% ± 1.7%, freedom from endoleaks of any type was 70.1 ± 3.4%, and freedom from secondary endovascular procedure 90.4% ± 2.6%. In addition, 61.6% (45/73) of patients exhibited sac shrinkage at five years. CONCLUSION In this five year report of the Endurant France registry, survival, re-intervention, and freedom from endoleak rates were comparable to recent EVAR registries and there was a high sac shrinkage rate. Secondary procedure and aneurysm rupture were lower than those of ACE, the French RCT which included older generation devices. This prospective registry demonstrates favourable five year outcomes of the Endurant stent graft used within IFU.
Collapse
Affiliation(s)
- Jean-Pierre Becquemin
- Institut Vasculaire Paris Est, Hopital Privé Paul d'Egine, Ramsay Group Champigny, France.
| | | | - Farah Issam
- Clinique Belledonne, Saint Martin d'Hères, France
| | | | | | | | | |
Collapse
|
34
|
Kato H, Kato N, Nakajima K, Higashigawa T, Ouchi T, Chino S, Tokui T, Sakuma H. Parallel Placement of Excluder Legs to Treat Abdominal Aortic Aneurysms with Aortoiliac Occlusive Lesion. Ann Vasc Dis 2020; 13:319-321. [PMID: 33384738 PMCID: PMC7751086 DOI: 10.3400/avd.cr.20-00044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
The effectiveness of endovascular aneurysm repair (EVAR) has been proven, but anatomical limitations, including narrow access route, may obstruct procedure of EVAR and cause serious complications. Parallel placement of Excluder legs (W. L. Gore & Associates, Inc., Newark, DE, USA) was established to treat patients with type IIIb endoleak or those with a narrow aorta, who could not be treated using a standard main body. In this report, we applied this technique in two patients with aortoiliac aneurysms with occlusive lesion.
Collapse
Affiliation(s)
- Hiroaki Kato
- Department of Radiology, Mie University Hospital
| | | | | | | | | | - Shuji Chino
- Department of Radiology, Ise Red Cross Hospital
| | - Toshiya Tokui
- Department of Cardiovascular Surgery, Ise Red Cross Hospital
| | | |
Collapse
|
35
|
Acute Distress Respiratory Syndrome and Cardiac Shock after AngioJet Thrombectomy for Acute Occlusion of an Aortic Endograft. Ann Vasc Surg 2020; 70:569.e11-569.e14. [PMID: 32927032 DOI: 10.1016/j.avsg.2020.08.128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 08/16/2020] [Accepted: 08/18/2020] [Indexed: 11/20/2022]
Abstract
Partial thrombosis or total occlusion of aortic or limb graft are possible complications after endovascular aneurysm repair. Different strategies for therapeutic management are available; these include open surgical techniques or endovascular treatments. The choice of the treatment depends on the patient's clinical conditions and on the timing of the thrombosis. Bypass still remains the first choice in case of chronic occlusion but in the last 10 years, the use of percutaneous mechanical/rheolytic thrombectomy systems is increasing. These devices can be used in case of acute or subacute onset of native arterial and venous thrombosis or embolism and in case of graft occlusion. AngioJet is a percutaneous rheolytic mechanical thrombectomy system. Through a pressurized saline solution jet, a low-pressure zone is made up and the thrombus is fragmented and aspirated by the device. Different transient adverse effects caused by lysis of the thrombus are described such as hemoglobinuria but in some cases the release of high doses of the thrombus degradation products such as heme and adenosine diphosphate can lead to fatal consequences for the patient. We reported a case of an acute onset of acute distress respiratory syndrome, pulmonary edema, cardiac shock, and renal failure following AngioJet thrombectomy in an 81-year-old man with an acute occlusion of an aortic endograft.
Collapse
|
36
|
Vacirca A, Faggioli G, Pini R, Spath P, Gallitto E, Mascoli C, Abualhin M, Gargiulo M. The Efficacy of a Protocol of Iliac Artery and Limb Treatment During EVAR in Minimising Early and Late Iliac Occlusion. Eur J Vasc Endovasc Surg 2020; 60:663-670. [PMID: 32855029 DOI: 10.1016/j.ejvs.2020.07.066] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 07/01/2020] [Accepted: 07/21/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE Iliac limb occlusion (ILO) is a complication of endovascular aortic repair (EVAR) and requires re-intervention in most cases. Attention to any intra-operative defect of iliac limbs and arteries may prevent ILO. The study aimed to analyse the long term effect of an intra-operative protocol of iliac limb treatment during EVAR on ILO. METHODS Patients treated from 2012 to 2017 for abdominal aortic aneurysm (AAA) with standard EVAR were collected prospectively. Pre-operative computed tomography angiography anatomical characteristics were evaluated. The protocol for intra-operative iliac limb management was: a. pre-EVAR angioplasty of common/external iliac artery stenosis; b. precise contralateral iliac limb deployment at the same level of the flow divider; c. iliac limb kissing ballooning with high pressure non-compliant balloons; d. iliac limb stenting for residual tortuosity/kink and adjunctive external iliac stenting for residual stenosis/dissection after EVAR. ILO was evaluated at 30 days and at follow up, which was performed by duplex ultrasonography before discharge, at three, six, and 12 months and yearly thereafter. Kaplan-Meier and Cox linear regression were used. RESULTS Four hundred and forty-two patients and 884 iliac limbs were included in the study. Severe iliac tortuosity and calcification were present in 15% (132/884) and 8% (70/884), respectively. External iliac angioplasty and stenting of iliac limb were performed in 2% (18/884) and 9.5% (84/884) of limbs. The thirty day mortality was 1.6%, with no ILO. At a mean follow up of 33 ± 12 months, ILO occurred in 7/884 (0.8%) limbs of six patients. Five ILO were treated by endovascular relining, two surgically: one by femorofemoral bypass and one by surgical explant. On univariable analysis, sac shrinkage was significantly associated with ILO (HR 1, 95% CI 0.8-2.5, p = .043). CONCLUSION A protocol of aggressive iliac limb treatment in EVAR leads to a very low rate of late ILO. The role of sac shrinkage in ILO should be investigated further.
Collapse
Affiliation(s)
- Andrea Vacirca
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy.
| | - Gianluca Faggioli
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | - Rodolfo Pini
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | - Paolo Spath
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | - Enrico Gallitto
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | - Chiara Mascoli
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | - Mohammad Abualhin
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| | - Mauro Gargiulo
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico Sant'Orsola-Malpighi, Bologna, Italy
| |
Collapse
|
37
|
Kim HO, Yim NY, Kim JK, Kang YJ, Lee BC. Endovascular Aneurysm Repair for Abdominal Aortic Aneurysm: A Comprehensive Review. Korean J Radiol 2020; 20:1247-1265. [PMID: 31339013 PMCID: PMC6658877 DOI: 10.3348/kjr.2018.0927] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Accepted: 05/02/2019] [Indexed: 12/19/2022] Open
Abstract
Abdominal aortic aneurysm (AAA) can be defined as an abnormal, progressive dilatation of the abdominal aorta, carrying a substantial risk for fatal aneurysmal rupture. Endovascular aneurysmal repair (EVAR) for AAA is a minimally invasive endovascular procedure that involves the placement of a bifurcated or tubular stent-graft over the AAA to exclude the aneurysm from arterial circulation. In contrast to open surgical repair, EVAR only requires a stab incision, shorter procedure time, and early recovery. Although EVAR seems to be an attractive solution with many advantages for AAA repair, there are detailed requirements and many important aspects should be understood before the procedure. In this comprehensive review, fundamental information regarding AAA and EVAR is presented.
Collapse
Affiliation(s)
- Hyoung Ook Kim
- Department of Radiology, Chonnam National University Hospital, Gwangju, Korea
| | - Nam Yeol Yim
- Department of Radiology, Chonnam National University Hospital, Gwangju, Korea.
| | - Jae Kyu Kim
- Department of Radiology, Chonnam National University Hospital, Gwangju, Korea
| | - Yang Jun Kang
- Department of Radiology, Chonnam National University Hwasun Hospital, Hwasun, Korea
| | - Byung Chan Lee
- Department of Radiology, Chonnam National University Hwasun Hospital, Hwasun, Korea
| |
Collapse
|
38
|
Risk Factors for Early and Late Iliac Limb Occlusions of Stent Grafts Extending to the External Iliac Artery after Endovascular Abdominal Aneurysm Repair. Ann Vasc Surg 2020; 70:401-410. [PMID: 32599115 DOI: 10.1016/j.avsg.2020.06.028] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Revised: 05/29/2020] [Accepted: 06/15/2020] [Indexed: 11/20/2022]
Abstract
BACKGROUND Iliac limb stent grafting to the external iliac artery (EIA) is a commonly performed procedure in various situation during endovascular abdominal aneurysm repair (EVAR). However, this procedure is associated with a risk of graft occlusion. We evaluated risk factors affecting occlusion among patients who underwent iliac limb stent-graft extension to the EIA. MATERIALS AND METHODS We compared occluded limbs with patent limbs during the follow-up period using variables, including anatomical values, demographics, and other factors. Thereafter, we divided the occluded limbs into early and late occlusion subgroups. The main and subgroup analyses used the same variables. Survival analysis was performed to evaluate time-dependent risk factors for late limb occlusion. RESULTS From 2007 to 2016, 766 iliac limbs from 383 patients who underwent EVAR were initially included in our analysis. Among them, 134 iliac limbs underwent limb extension to the EIA. The limb extension was a significant risk factor for occlusion (hazard ratio = 6.34, P < 0.001). Occlusion occurred in 10 patients who underwent iliac limb extension. The size of common iliac artery (CIA) was associated with occlusion. The most significant factor was iliac bifurcation diameter (patent vs. occluded limbs, 21.6 ± 7.6 vs. 27.5 ± 9.5 mm, P = 0.005). Subgroup analysis revealed that the CIAs of the early occlusion subgroup were generally more tortuous (1.16 ± 0.33 vs. 1.47 ± 0.25, P = 0.091) and longer (53 ± 24 vs. 74 ± 9, P = 0.01) than those of the patent limb group. In addition, the EIA diameters of the late occlusion subgroup were narrower than those of the patent limb group (10.9 ± 1.6 mm vs. 9.1 ± 0.8 mm, P = 0.011). Using the log-rank test, those patients with an EIA diameter narrower than 10.1 mm had a higher risk for late limb occlusion (log-rank χ2 = 5.73, P = 0.017) and the patients who did not take at least a single antiplatelet agent had a significantly higher chance of limb occlusion (log-rank χ2 = 11.029, P = 0.001). In addition, the patients who did not take a statin had a higher risk for late limb occlusion (log-rank χ2 = 7.41, P = 0.007). CONCLUSIONS Among patients who underwent EVAR with iliac limb extension, the CIA length affected early limb occlusion and predisposed patients to vessel injury or stent-graft kinking, and there was the possibility that CIA tortuosity was associated with a higher risk. The late occlusion subgroup had narrower EIAs than the patent limb group. Appropriate antiplatelet and statin therapy is expected to play a key role in the prevention of late limb occlusion after EVAR.
Collapse
|
39
|
Tigkiropoulos K, Stavridis K, Lazaridis I, Bontinis E, Zournatzi I, Kolaki N, Karamanos D, Saratzis N. Outcomes of Endovascular Aneurysm Repair Using the Anaconda Stent-Graft. J Endovasc Ther 2020; 27:462-467. [PMID: 32517558 DOI: 10.1177/1526602820918875] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose: To report outcomes of elective endovascular aneurysm repair (EVAR) using the Anaconda stent-graft in a tertiary vascular center. Materials and Methods: A retrospective study was conducted of 271 patients (mean age 71.5 years; 260 men) who underwent elective EVAR for abdominal aortic aneurysm using the Anaconda stent-graft from January 2006 to January 2017. Median aneurysm diameter was 58 mm (range 50-90). All patients were anatomically suitable for EVAR according to the 2003 version of the instructions for use. Follow-up included computed tomography angiography at 1, 6, and 12 months and yearly thereafter for the first 4 years and then every 2 years. Primary outcomes included technical success and 30-day aneurysm-related mortality and complications; secondary outcomes were overall and aneurysm-related mortality and aneurysm-related morbidity in follow-up. Results: The Anaconda stent-graft was implanted successfully in all patients. Primary and secondary technical success rates were 99.6% and 100%, respectively. Three patients (1.1%) died within 30 days of causes unrelated to the aneurysm, while 15 patients (5.5%) suffered perioperative complications. Median follow-up was 72 months (range 14-141). The overall type I endoleak rate was 4.7% (11 proximal, 2 distal). Late aneurysm-related complications were observed in 48 patients (17.3%); aneurysm-related mortality was 1.4% (n=4). Non-aneurysm-related mortality was 21.0% (n=57). Freedom from reintervention was 95.2% at 1 year, 98% at 2 years, and 90% at 6 years. There was no significant difference in the overall limb graft occlusion rate between the second- and third-generation devices. Conclusion: Results in our cohort study demonstrate that the Anaconda stent-graft has satisfactory early and late results with low aneurysm-related mortality.
Collapse
Affiliation(s)
- Konstantinos Tigkiropoulos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Kyriakos Stavridis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Ioannis Lazaridis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Evangelos Bontinis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Ioulia Zournatzi
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Nikoletta Kolaki
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Dimitrios Karamanos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Nikolaos Saratzis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| |
Collapse
|
40
|
D'Oria M, Mendes BC, Bews K, Hanson K, Johnstone J, Shuja F, Kalra M, Bower T, Oderich GS, DeMartino RR. Perioperative Outcomes After Use of Iliac Branch Devices Compared With Hypogastric Occlusion or Open Surgery for Elective Treatment of Aortoiliac Aneurysms in the NSQIP Database. Ann Vasc Surg 2020; 62:35-44. [DOI: 10.1016/j.avsg.2019.04.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 04/09/2019] [Accepted: 04/13/2019] [Indexed: 12/20/2022]
|
41
|
Lotto CE, Sharma G, Walsh JP, Shah SK, Nguyen LL, Ozaki CK, Menard MT, Belkin M. The impact of combined iliac occlusive disease and aortic aneurysm on open surgical repair. J Vasc Surg 2019; 71:2021-2028.e1. [PMID: 31727458 DOI: 10.1016/j.jvs.2019.08.249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 08/11/2019] [Indexed: 11/24/2022]
Abstract
OBJECTIVE Severe aortoiliac occlusive disease is a relative contraindication for endovascular aneurysm repair, owing to an association with high stent graft-related complication and reintervention rates in this population. Open AAA repair requiring aortofemoral bypass (AFB), however, may represent a unique population with differing outcomes from standard open repair. We sought to compare the demographic and procedural characteristics, as well as outcomes of patients undergoing standard intra-abdominal repairs (STD) versus those requiring AFB. METHODS Using a prospectively maintained database, we retrospectively identified patients who underwent open AAA repair from 1994 to 2017. A total of 1087 consecutive cases were performed consisting of 981 STD (681 tube graft, 300 aortoiliac) and 106 AFB cases. Demographics, procedural data, postoperative complications, and long-term survival were analyzed. RESULTS The AFB cohort had more women (39.0 vs 22.8%; P = .001) and higher rates of hypertension (81.1 vs 69.8%; P = .015), chronic obstructive pulmonary disease (28.3 vs 17.4%; P = .006), and smoking (50.9 vs 36%; P = .002). The AFB group had smaller mean aortic (5.22 vs 5.77 cm; P = .001) and graft (17.08 vs 18.2 mm; P = .001) diameters. Proximal clamp position and blood loss were equivalent, although total anesthesia time was longer (295 vs 234 minutes; P = .001) in the AFB cohort. Overall 30-day postoperative morbidity (38.7 vs 24.8%; P = .002) was higher in the AFB group. Specifically, postoperative renal insufficiency (8.2 vs 3.4%; P = .032), wound infection (5.7 vs 1.2%; P = .005), and hematoma/seroma (5.7 vs 1.2%; P = .003) were more likely. Hospital length of stay was longer for AFB (11.9 vs 9.9 days; P = .007). The 30-day mortality (0.9% AFB vs 1.8% STD; P = .50) and major morbidity (17 vs 11.5%; P = .10) did not differ. Reintervention rate within 30 days of the initial surgery (12.3 vs 4.6; P = .001) and overall (33 vs 18.9%; P = .001) was higher in the AFB group. Long-term survival was lower in the AFB group (5-year survival: 63.1% AFB vs 71.9% STD; hazard ratio 0.76, log-rank P = .047). Multivariate regression analysis identified age, comorbid conditions, and aneurysm characteristics-rather than repair type-as independent predictors of 30-day reintervention and mortality at 5 years. CONCLUSIONS Patients requiring AFB for AAA owing to associated iliac occlusive disease have more preoperative comorbidities, postoperative complications, a longer length of stay, reintervention rates and shorter 5-year survival. Patient and aneurysm characteristics rather than surgical repair type appear to be responsible for these differences. Nevertheless, 30-day mortality and major morbidity were comparable, making AFB an attractive alternative to endovascular aneurysm repair in patients with advanced iliac occlusive disease.
Collapse
Affiliation(s)
- Christine E Lotto
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - Gaurav Sharma
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - Jillian P Walsh
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - Samir K Shah
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - Louis L Nguyen
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - C Keith Ozaki
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - Matthew T Menard
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass
| | - Michael Belkin
- Division of Vascular and Endovascular Surgery, Brigham and Women's Heart and Vascular Center/Harvard Medical School, Boston, Mass.
| |
Collapse
|
42
|
Coelho A, Nogueira C, Lobo M, Gouveia R, Campos J, Augusto R, Coelho N, Semião AC, Ribeiro JP, Canedo A. Impact of Post-EVAR Graft Limb Kinking in EVAR Limb Occlusion: Aetiology, Early Diagnosis, and Management. Eur J Vasc Endovasc Surg 2019; 58:681-689. [DOI: 10.1016/j.ejvs.2019.03.019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Revised: 03/10/2019] [Accepted: 03/11/2019] [Indexed: 12/26/2022]
|
43
|
Hemmler A, Lutz B, Reeps C, Gee MW. In silico study of vessel and stent-graft parameters on the potential success of endovascular aneurysm repair. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2019; 35:e3237. [PMID: 31315160 DOI: 10.1002/cnm.3237] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 05/29/2019] [Accepted: 07/10/2019] [Indexed: 06/10/2023]
Abstract
The variety of stent-graft (SG) design variables (eg, SG type and degree of SG oversizing) and the complexity of decision making whether a patient is suitable for endovascular aneurysm repair (EVAR) raise the need for the development of predictive tools to assist clinicians in the preinterventional planning phase. Recently, some in silico EVAR methods have been developed to predict the deployed SG configuration. However, only few studies investigated how to assess the in silico EVAR outcome with respect to EVAR complication likelihoods (eg, endoleaks and SG migration). Based on a large literature study, in this contribution, 20 mechanical and geometrical parameters (eg, SG drag force and SG fixation force) are defined to evaluate the quality of the in silico EVAR outcome. For a cohort of n = 146 realizations of parameterized vessel and SG geometries, the in silico EVAR results are studied with respect to these mechanical and geometrical parameters. All degrees of SG oversizing in the range between 5% and 40% are investigated continuously by a computationally efficient parameter continuation approach. The in silico investigations have shown that the mechanical and geometrical parameters are able to indicate candidates at high risk of postinterventional complications. Hence, this study provides the basis for the development of a simulation-based metric to assess the potential success of EVAR based on engineering parameters.
Collapse
Affiliation(s)
- André Hemmler
- Mechanics & High Performance Computing Group, Technische Universität München, Parkring 35, Garching b. München, 85748, Germany
| | - Brigitta Lutz
- Klinik für Viszeral-, Thorax- und Gefäßchirurgie, Universitätsklinikum Carl Gustav Carus Dresden, Fetscherstraße 74, Dresden, 01307, Germany
| | - Christian Reeps
- Klinik für Viszeral-, Thorax- und Gefäßchirurgie, Universitätsklinikum Carl Gustav Carus Dresden, Fetscherstraße 74, Dresden, 01307, Germany
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Technische Universität München, Parkring 35, Garching b. München, 85748, Germany
| |
Collapse
|
44
|
Grip O, Wanhainen A, Björck M. Temporal Trends and Management of Acute Aortic Occlusion: A 21 Year Experience. Eur J Vasc Endovasc Surg 2019; 58:690-696. [DOI: 10.1016/j.ejvs.2019.05.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 05/20/2019] [Accepted: 05/21/2019] [Indexed: 11/27/2022]
|
45
|
Catanese V, Sangiorgi G, Sotgiu G, Saderi L, Settembrini A, Donelli C, Martelli E. Clinical and anatomical variables associated in the literature to limb graft occlusion after endovascular aneurysm repair compared to the experience of a tertiary referral center. MINERVA CHIR 2019; 75:51-59. [PMID: 31663308 DOI: 10.23736/s0026-4733.19.08199-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
INTRODUCTION Limb graft occlusion (LGO) is the third reason for hospital readmission after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm. We reviewed the clinical features, incidence, anatomical and devices related predictive factors for LGO after EVAR, and compared them with our experience. EVIDENCE ACQUISITION EVAR between 2010-2017 were included. Patients with LGO (LGO group) were matched for age and type of endograft with the rest of the entire cohort without LGO (control group). Clinical, anatomical, operative, outcome, and follow-up data were collected. EVIDENCE SYNTHESIS Two hundred seventy-six EVAR, (30 aorto-uniliac), 276 patients. The incidence of LGO was 2.5% (seven limbs, seven patients) at 27±24.6 days. Symptomatic patients were successfully treated. No mortality, limb loss, critical limb ischemia or residual claudication due to LGO was observed. Fifty patients resulted from the matching. Among the predictive factors of LGO between the two groups, significant differences were observed in graft limb oversizing ≥15% (57.1% vs. 8%, P=0.005), or kinking (42.9% vs. 2%, P=0.01), and diameter of the aortic bifurcation <20 mm (71.4% vs. 20%, P=0.01). Logistic regression analysis showed that these three variables increased the risk of LGO (P=0.003, P=0.006, and P=0.01, respectively). CONCLUSIONS The strongest predictive factors of LGO issued from our review were: extension in the external iliac artery, or small diameter; tortuous, angled, and calcific iliac axis; excessive oversizing of the limb graft, or kinking; use of old generation devices; EVAR performed outside the instructions for use. Limb graft oversizing >15%, or kinking, and aortic bifurcation <20 mm appear to be independent predictive factors of LGO.
Collapse
Affiliation(s)
- Vincenzo Catanese
- Division and Residency Program in Vascular Surgery, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari, Italy
| | - Giuseppe Sangiorgi
- Division and Residency Program in Vascular Surgery, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari, Italy.,Division of Cardiology, Department of Systems Medicine, Tor Vergata University, Rome, Italy
| | - Giovanni Sotgiu
- Clinical Epidemiology and Medical Statistics Unit, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari, Italy
| | - Laura Saderi
- Clinical Epidemiology and Medical Statistics Unit, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari, Italy
| | - Alberto Settembrini
- Division of Vascular Surgery, Maggiore Polyclinic Hospital, Ca' Granda IRCCS and Foundation, Milan, Italy
| | - Carlotta Donelli
- Division and Residency Program in Vascular Surgery, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari, Italy
| | - Eugenio Martelli
- Division and Residency Program in Vascular Surgery, Department of Medical, Surgical and Experimental Sciences, University of Sassari, Sassari, Italy -
| |
Collapse
|
46
|
Shintani T, Obara H, Matsubara K, Hayashi K, Hayashi M, Ono S, Shimogawara T, Shibutani S, Watada S, Sekimoto Y, Uchida N, Asami A, Fujii T, Harada H, Fujimura N, Sato Y, Kitagawa Y. Impact of Stent Graft Design on External Iliac Artery Limb Occlusion Rates After Endovascular Aneurysm Repair: Post-hoc Analysis of a Japanese Multicentre Database. Eur J Vasc Endovasc Surg 2019; 58:839-847. [PMID: 31607678 DOI: 10.1016/j.ejvs.2019.03.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 03/13/2019] [Accepted: 03/20/2019] [Indexed: 10/25/2022]
Abstract
OBJECTIVE/BACKGROUND It was hypothesised that a helical stent with expanded polytetrafluoroethylene (ePTFE) grafts could provide a preventive effect for external iliac artery (EIA) limb occlusion following endovascular aortic aneurysm repair (EVAR). Therefore, a post-hoc analysis of a Japanese multicentre database was conducted to assess the impact of the stent graft design on EIA limb occlusion rates. METHODS Patients who underwent EVAR with EIA limb deployment between 2008 and 2016 were evaluated. The stent graft limbs were divided into two groups: group A comprised stent graft limbs made of a helical stent with ePTFE grafts (Excluder; n = 255), and group B comprised stent graft limbs made of a Z stent with polyester grafts (Zenith, Flex and Endurant; n = 173). The main outcome was the incidence of limb occlusion and severe limb stenosis (EIA related limb complications). The risk factors for EIA related limb complications were analysed and the midterm results between groups A and B compared. Fine-Gray generalisation of the proportional hazards model was used after propensity score matching to calculate the hazard ratio (HR). RESULTS One complication occurred in group A and 10 complications occurred in group B. The risk factors for EIA related limb complications for the entire group were a stent graft limb size ≤10 mm (HR 5.41; p = .01) and inclusion in group B (HR 14.9; p = .009). After propensity matching, group A (n = 159) was matched with group B (n = 159). The cumulative incidence function of EIA related limb complications at five years was 0.66% in group A and 7.8% in group B (HR 8.67; p = .039). CONCLUSION Stent graft design can affect limb patency in EIA limb deployment. When EIA limb deployment is necessary for patients with a small EIA, such as Japanese patients, stent graft limbs made of a helical stent with ePTFE should be used to reduce the risk of limb occlusion.
Collapse
Affiliation(s)
- Tsunehiro Shintani
- Department of Vascular Surgery, Shizuoka Red Cross Hospital, Shizuoka, Japan
| | - Hideaki Obara
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan.
| | - Kentaro Matsubara
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Keita Hayashi
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Masanori Hayashi
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Shigeshi Ono
- Department of Surgery, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan
| | - Tatsuya Shimogawara
- Department of Surgery, Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan
| | - Shintaro Shibutani
- Department of Vascular Surgery, Saiseikai Yokohamashi Tobu Hospital, Kawasaki, Japan
| | - Susumu Watada
- Department of Surgery, Kawasaki Municipal Hospital, Kawasaki, Japan
| | | | - Norio Uchida
- Department of Surgery, Mito Red Cross Hospital, Mito, Japan
| | - Atsunori Asami
- Department of Surgery, Saitama Municipal Hospital, Saitama, Japan
| | - Taku Fujii
- Department of Surgery, Saitama Municipal Hospital, Saitama, Japan; Department of Surgery, Hiratsuka City Hospital, Hiratsuka, Japan
| | - Hirohisa Harada
- Department of Surgery, Saiseikai Central Hospital, Tokyo, Japan
| | - Naoki Fujimura
- Department of Surgery, Saiseikai Central Hospital, Tokyo, Japan
| | - Yasunori Sato
- Department of Preventive Medicine and Public Health, Keio University School of Medicine, Tokyo, Japan
| | - Yuko Kitagawa
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
47
|
Iwakoshi S, Nakai T, Ichihashi S, Inoue T, Sakaguchi S, Hirose T, Tabayashi N, Watkins AC, Kichikawa K. Conformability and Efficacy of the Zenith Spiral Z Leg Compared with the Zenith Flex Leg in Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg 2019; 59:127-133. [DOI: 10.1016/j.avsg.2019.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 02/21/2019] [Accepted: 02/22/2019] [Indexed: 10/26/2022]
|
48
|
Argyriou C, Georgiadis GS. Validation of Duplex Ultrasound Graft Surveillance in the Immediate Postoperative Period. AORTA : OFFICIAL JOURNAL OF THE AORTIC INSTITUTE AT YALE-NEW HAVEN HOSPITAL 2019; 7:27-28. [PMID: 31330550 PMCID: PMC6645986 DOI: 10.1055/s-0039-1688435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
A femoral crossover polytetrafluoroethylene graft was performed in a patient immediately, after a failed iliac endograft limb recanalization, performed 2 years after endovascular aortic aneurysm repair. Although graft patency was confirmed clinically by palpation of groin pulses as well as noninvasively by segmental pressure measurements and Doppler examination, in the immediate postoperative period, duplex ultrasound failed to show any blood flow inside the graft lumen until the fourth postoperative day. Subcutaneous air and air tapped within the wall structure of the graft are possible explanation for the failure to show flow.
Collapse
Affiliation(s)
- Christos Argyriou
- Department of Vascular and Endovascular Surgery, University General Hospital of Evros, "Democritus" University of Thrace, Alexandroupolis, Greece
| | - George S Georgiadis
- Department of Vascular and Endovascular Surgery, University General Hospital of Evros, "Democritus" University of Thrace, Alexandroupolis, Greece
| |
Collapse
|
49
|
Spencer B, Aziz F. Excessive tortuosity of the iliac arteries is an indication for open abdominal aortic aneurysm repair. J Vasc Surg 2019; 70:272-273. [PMID: 31230645 DOI: 10.1016/j.jvs.2019.04.439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 04/03/2019] [Indexed: 11/15/2022]
Affiliation(s)
- Brianna Spencer
- Department of Surgery, Pennsylvania State University College of Medicine, Hershey, Pa
| | - Faisal Aziz
- Division of Vascular Surgery, Penn State Heart and Vascular Institute, Pennsylvania State University College of Medicine, Hershey, Pa.
| |
Collapse
|
50
|
Brazzelli M, Hernández R, Sharma P, Robertson C, Shimonovich M, MacLennan G, Fraser C, Jamieson R, Vallabhaneni SR. Contrast-enhanced ultrasound and/or colour duplex ultrasound for surveillance after endovascular abdominal aortic aneurysm repair: a systematic review and economic evaluation. Health Technol Assess 2019; 22:1-220. [PMID: 30543179 DOI: 10.3310/hta22720] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Endovascular abdominal aortic aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) is less invasive than open surgery, but may be associated with important complications. Patients receiving EVAR require long-term surveillance to detect abnormalities and direct treatments. Computed tomography angiography (CTA) has been the most common imaging modality adopted for EVAR surveillance, but it is associated with repeated radiation exposure and the risk of contrast-related nephropathy. Colour duplex ultrasound (CDU) and, more recently, contrast-enhanced ultrasound (CEU) have been suggested as possible, safer, alternatives to CTA. OBJECTIVES To assess the clinical effectiveness and cost-effectiveness of imaging strategies, using either CDU or CEU alone or in conjunction with plain radiography, compared with CTA for EVAR surveillance. DATA SOURCES Major electronic databases were searched, including MEDLINE, EMBASE, Science Citation Index, Scopus' Articles-in-Press, Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE) and NHS Economic Evaluation Database from 1996 onwards. We also searched for relevant ongoing studies and conference proceedings. The final searches were undertaken in September 2016. METHODS We conducted a systematic review of randomised controlled trials and cohort studies of patients with AAAs who were receiving surveillance using CTA, CDU and CEU with or without plain radiography. Three reviewers were involved in the study selection, data extraction and risk-of-bias assessment. We developed a Markov model based on five surveillance strategies: (1) annual CTA; (2) annual CDU; (3) annual CEU; (4) CDU together with CTA at 1 year, followed by CDU on an annual basis; and (5) CEU together with CTA at 1 year, followed by CEU on an annual basis. All of these strategies also considered plain radiography on an annual basis. RESULTS We identified two non-randomised comparative studies and 25 cohort studies of interventions, and nine systematic reviews of diagnostic accuracy. Overall, the proportion of patients who required reintervention ranged from 1.1% (mean follow-up of 24 months) to 23.8% (mean follow-up of 32 months). Reintervention was mainly required for patients with thrombosis and types I-III endoleaks. All-cause mortality ranged from 2.7% (mean follow-up of 24 months) to 42% (mean follow-up of 54.8 months). Aneurysm-related mortality occurred in < 1% of the participants. Strategies based on early and mid-term CTA and/or CDU and long-term CDU surveillance were broadly comparable with those based on a combination of CTA and CDU throughout the follow-up period in terms of clinical complications, reinterventions and mortality. The economic evaluation showed that a CDU-based strategy generated lower expected costs and higher quality-adjusted life-year (QALYs) than a CTA-based strategy and has a 63% probability of being cost-effective at a £30,000 willingness-to-pay-per-QALY threshold. A CEU-based strategy generated more QALYs, but at higher costs, and became cost-effective only for high-risk patient groups. LIMITATIONS Most studies were rated as being at a high or moderate risk of bias. No studies compared CDU with CEU. Substantial clinical heterogeneity precluded a formal synthesis of results. The economic model was hindered by a lack of suitable data. CONCLUSIONS Current surveillance practice is very heterogeneous. CDU may be a safe and cost-effective alternative to CTA, with CTA being reserved for abnormal/inconclusive CDU cases. FUTURE WORK Research is needed to validate the safety of modified, more-targeted surveillance protocols based on the use of CDU and CEU. The role of radiography for surveillance after EVAR requires clarification. STUDY REGISTRATION This study is registered as PROSPERO CRD42016036475. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Miriam Brazzelli
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Rodolfo Hernández
- Health Economics Research Unit, University of Aberdeen, Aberdeen, UK
| | - Pawana Sharma
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Clare Robertson
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | | | - Graeme MacLennan
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Cynthia Fraser
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | | | | |
Collapse
|