1
|
Reyes Valdivia A, Oikonomou K, Milner R, Kasprzak P, Reijnen MMPJ, Pitoulias G, Torsello GB, Pfister K, de Vries JPPM, Chaudhuri A. The Effect of EndoAnchors on Aneurysm Sac Regression for Patients Treated With Infrarenal Endovascular Repair With Hostile Neck Anatomies: A Propensity Scored Analysis. J Endovasc Ther 2024; 31:438-449. [PMID: 36214450 DOI: 10.1177/15266028221127839] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To analyze sac evolution patterns in matched patients with hostile neck anatomy (HNA) treated with standard endovascular aneurysm repair (sEVAR) and endosutured aneurysm repair (ESAR). METHODS Observational retrospective study using prospectively collected data between June 2010 and December 2019. ESAR group data were extracted from the primary arm of the PERU registry with an assigned identifier (NCT04100499) at 8 centers and those from the sEVAR came from 4 centers. Suitability for inclusion required: no proximal endograft adjuncts (besides EndoAnchor use), ≤15 mm neck length and minimum of 12-months follow-up imaging. Bubble-shaped neck (noncylindrical short neck with discontinuous seal) aspect was analyzed. Both groups were analyzed using propensity score matching (PSM) for aortic neck length, width, angulation, and device fixation type. Main outcome assessed was sac evolution patterns (sac expansion and regression were defined as >5mm increase or decrease, of the maximum sac diameter respectively; all AAAs within this ±5 mm range in diameter change were considered stable) and secondary outcomes were type-Ia endoleaks; other endoleaks and mortality. A power analysis calculation >80% was confirmed for sac regression evaluation. RESULTS After exclusions, PSM resulted in 96 ESAR and 96 sEVAR patients. Mean imaging follow-up (months) was 44.4±21.3 versus 43.0±19.6 (p=0.643), respectively. The overall number of patients achieving sac regression was higher in the ESAR group (n=57, 59.4% vs n=31, 32.3%; p<0.001) and the cumulative sac regression achieved at 5 years was 65% versus 38% (p=0.003) in favor of the ESAR group. There were no statistically significant differences in type-Ia endoleak and/or other endoleaks. Univariate analysis for sac regression patients in the sEVAR and ESAR group individually showed the bubble-shape neck as a predictor of sac regression failure. There were no statistical differences in overall and aneurysm-related mortality. CONCLUSION Endosutured aneurysm repair provided improved rates of sac regression for patients with AAA and HNA when compared with sEVAR at midterm and up to 5 years, despite similar rates of type-Ia endoleaks, and the need to consider some important limitations. The presence of bubble-shaped neck was a predictor of sac regression failure for both groups equally. CLINICAL IMPACT The use of EndoAnchors aids and improves EVAR treatment in hostile neck anatomies by an increased rate of sac regression when compared to EVAR treatment alone in up to 5 year analysis. Moreover, a trend to reduced number of type Ia endoleaks is also achieved, although not significant in the present study. This data, adds to current and growing evidence on the usefulness of EndoAnchors for AAA endovascular treatment.
Collapse
Affiliation(s)
- Andrés Reyes Valdivia
- Department of Vascular and Endovascular Surgery, Ramón y Cajal's University Hospital, Madrid, Spain
| | - Kyriakos Oikonomou
- Department of Vascular Surgery, University Medical Centre Regensburg, Regensburg, Germany
- Department of Vascular and Endovascular Surgery, Cardiovascular Surgery Clinic, University Hospital Frankfurt and Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Ross Milner
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, University of Chicago Medicine, Chicago, IL, USA
| | - Piotr Kasprzak
- Department of Vascular Surgery, University Medical Centre Regensburg, Regensburg, Germany
| | - Michel M P J Reijnen
- Department of Surgery, Rijnstate, Arnhem, The Netherlands
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Georgios Pitoulias
- Division of Vascular Surgery, 2nd Department of Surgery, Faculty of Medicine, "G. Gennimatas" Thessaloniki General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | | | - Karin Pfister
- Department of Vascular Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Jean-Paul P M de Vries
- Division of Vascular Surgery, Department of Surgery, University Medical Centre Groningen, Groningen, The Netherlands
- Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Arindam Chaudhuri
- Bedfordshire-Milton Keynes Vascular Center, Bedfordshire Hospitals NHS Foundation Trust, Bedford, UK
| |
Collapse
|
2
|
Pitros C, Mansi P, Kakkos S. Endografts for the treatment of abdominal aortic aneurysms with a hostile neck anatomy: A systematic review. Front Surg 2022; 9:872705. [PMID: 36061064 PMCID: PMC9428821 DOI: 10.3389/fsurg.2022.872705] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 07/08/2022] [Indexed: 11/28/2022] Open
Abstract
Background Endovascular aortic repair (EVAR) of abdominal aortic aneurysms (AAAs) has emerged as a better alternative to conventional open surgery for AAAs. The purpose of the review is to define the improvement in the clinical management of the patient with hostile neck AAAs due to the introduction of new endografts while giving a thorough description of their instructions for use (IFUs), main characteristics and part sizing, reporting their outcomes from clinical studies and categorizing their usability. Methods A MEDLINE search was conducted using keyword-specific combinations. Clinical studies were searched via the clinicaltrials.gov website. Relevant articles' references were also hand-searched. Results We retrieved 640 records describing Alto, Ovation iX, Treovance, Aorfix, Anaconda, Conformable, and Endurant II/IIs endografts. Aortic necks >60° can be managed with Anaconda, Aorfix, and Conformable, which can treat up to 90° necks requiring ≥15 mm (Anaconda ≥20 mm), and Treovance, which is eligible for necks ≤75° with ≥15 mm length. Ovation's innovation of combining polymer-filled O-rings with integral anchors can treat conical necked AAAs giving Ovation iX and Alto an advantage. Short-necked AAAs can be treated with Alto, eligible for necks as short as 7 mm, and Endurant II, which can treat ≥10 mm necks or 4 mm if used in conjunction with the EndoAnchors system, respectively. Alto and Conformable report a 100% technical success rate, absence of AAA-related death, migration, ruptures, and limb occlusion during follow-up. Endurant II and Ovation iX report >99% technical success rate and are almost free from the AAA mortality rate, ruptures, migration, and limb occlusion, while Ovation iX has a high rate of sac dilation (15.5%) in a 5-year follow-up. Anaconda is slightly better than Aorfix and Treovance, which are related to the lowest technical success rates, 98.3%, 96.3%, and 96%, respectively. Aorfix has the highest AAA mortality rate, 4% in a 60 month follow-up. Conclusion Most new generation endografts described have comparable results. They broaden the eligibility of patients for EVAR due to their unique technical characteristics described. There is a lack of comparative studies for newer endografts and postmarket clinical studies with long-term results concerning the most recently approved devices described, Alto and Conformable.
Collapse
Affiliation(s)
- Christos Pitros
- Department of Vascular Surgery, University of Patras Medical School, Patras, Greece
| | | | - Stavros Kakkos
- Department of Vascular Surgery, University of Patras Medical School, Patras, Greece
- Correspondence: Stavros Kakkos
| |
Collapse
|
3
|
Georgakarakos E, Kapoulas K, Bekos C, Georgiadis GS. The Ovation Alto platform: extending endovascular treatment beyond short-necked abdominal aortic aneurysms. Expert Rev Med Devices 2022; 19:463-467. [PMID: 35924393 DOI: 10.1080/17434440.2022.2109962] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Efstratios Georgakarakos
- Department of Vascular Surgery, University Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, Greece
| | | | - Christos Bekos
- Department of Vascular Surgery, General Hospital of Nicosia, Cuprus
| | - George S Georgiadis
- Department of Vascular Surgery, University Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, Greece
| |
Collapse
|
4
|
Efthymiou FO, Tsimpoukis AL, Papatsirou MA, Kouri NK, Papadoulas SI, Nikolakopoulos KM, Kakkos SK. Endovascular Juxtarenal Aortic Aneurysm Repair Using the ALTO Abdominal Stent Graft System: The First Case Series. Vasc Specialist Int 2022; 38:17. [PMID: 35748180 PMCID: PMC9233984 DOI: 10.5758/vsi.220004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 03/21/2022] [Accepted: 04/25/2022] [Indexed: 11/23/2022] Open
Abstract
The ALTO abdominal stent graft system (Endologix Inc., Irvine, CA, USA) is a latest-generation polymer-based device used to treat patients with abdominal aortic aneurysms. The present study describes the first case series of patients with abdominal aortic aneurysms, including two patients with juxtarenal aneurysms, treated using the ALTO stent graft system. Six males were treated using the ALTO device at a single public center. All procedures were uneventful, and the dosimetric results recorded in terms of kerma-area product and fluoroscopy time were similar to those reported in previous studies. At the 1-month follow-up, computed tomography angiography showed no evidence of endoleak, device migration, thrombosis, or structural graft failure. This clinical series demonstrates that the use of the ALTO stent graft system is associated with promising patient outcomes. Lifelong postoperative imaging surveillance may highlight possible late failures and suggest potential graft improvements.
Collapse
Affiliation(s)
- Fotios O. Efthymiou
- Departments of Medical Physics, School of Medicine, University of Patras, Patras, Greece
| | - Andreas L. Tsimpoukis
- Departments of Vascular Surgery, School of Medicine, University of Patras, Patras, Greece
| | - Marianna A. Papatsirou
- Departments of Vascular Surgery, School of Medicine, University of Patras, Patras, Greece
| | - Natasa K. Kouri
- Departments of Vascular Surgery, School of Medicine, University of Patras, Patras, Greece
| | - Spyros I. Papadoulas
- Departments of Vascular Surgery, School of Medicine, University of Patras, Patras, Greece
| | | | - Stavros K. Kakkos
- Departments of Vascular Surgery, School of Medicine, University of Patras, Patras, Greece
| |
Collapse
|
5
|
de Donato G, Pasqui E, Panzano C, Galzerano G, Cappelli A, Palasciano G. Early Experience with the New Ovation Alto Stent Graft in Endovascular Abdominal Aortic Aneurysm Repair. EJVES Vasc Forum 2021; 54:7-12. [PMID: 34950916 PMCID: PMC8671859 DOI: 10.1016/j.ejvsvf.2021.11.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 10/21/2021] [Accepted: 11/22/2021] [Indexed: 12/02/2022] Open
Abstract
INTRODUCTION Since 2010, the Ovation Abdominal Stent Graft System has offered a new sealing concept, achieved by a sealing ring filled with polymer 13 mm from the renal arteries. In the latest version, called Ovation Alto, the sealing ring is relocated 6 mm closer to the top of the fabric. This study describes the early clinical outcomes, after CE Mark approval in August 2020, of endovascular aneurysm repair with the Alto endograft. REPORT Eleven patients underwent endovascular aneurysm repair with implantation of Ovation Alto endografts. All patients were male, and the median age was 75 (IQR 5.5) years. Hostile proximal aortic neck (<10 mm) was identified in six cases (54.5%). All procedures were performed using bilateral percutaneous approaches with no groin complications. The median procedure time was 58 (IQR 7.2) minutes, the median contrast volume used was 65 (IQR 4.2) mL, and the median blood loss 40 (IQR 12.4) mL. Technical success was achieved in all cases. The median stent graft landing distance between the top of the fabric and the lowest renal artery was 1.4 (IQR 0.8) mm. No intra-operative high flow endoleaks were registered. At one and six month follow up, there was 100% clinical success (no type I/III endoleak, sac enlargement, stent graft migration, polymer leakage, abdominal aortic aneurysm related mortality, or secondary intervention). DISCUSSION Initial experience confirms the early technical and clinical success of the new Ovation Alto stent graft. Technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on label. Further studies are needed to evaluate long term durability outcomes.
Collapse
Affiliation(s)
- Gianmarco de Donato
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Edoardo Pasqui
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Claudia Panzano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Giuseppe Galzerano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Alessandro Cappelli
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Giancarlo Palasciano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| |
Collapse
|
6
|
Chaudhuri A, Reyes-Valdivia A, Badawy A. Endovascular aneurysm repair for abdominal aortic aneurysms with hostile neck anatomy: Getting it right the first time avoids problems the second time round. INTERNATIONAL JOURNAL OF SURGERY OPEN 2021. [DOI: 10.1016/j.ijso.2021.100347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Chaudhuri A. Focused Interventions Aimed at Increasing Sac Shrinkage Rates After Endovascular Aneurysm Repair: Awaiting a Cohesive Analysis. J Endovasc Ther 2021; 28:484-485. [PMID: 33467945 DOI: 10.1177/1526602821989344] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Arindam Chaudhuri
- Bedfordshire-Milton Keynes Vascular Centre, Bedfordshire Hospitals NHS Foundation Trust, Bedford, UK
| |
Collapse
|