1
|
Araújo GTS, Faustino LC, Silva RMP, Cantanhêde W, Gerôncio ETS. Simple graphite/PVC ink-designed paper-based electrodes integrated with a 3D-printed electrochemical device for affordable analyses. Mikrochim Acta 2025; 192:191. [PMID: 40011243 DOI: 10.1007/s00604-025-07041-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2024] [Accepted: 02/11/2025] [Indexed: 02/28/2025]
Abstract
A simple and cost-effective methodology for manufacturing a portable electroanalytical device is reported. The device is based on a graphite/polyvinyl chloride (PVC) paper-based electrode coupled to a miniaturized 3D-printed electrochemical cell (3DEC). The 3DEC was designed to ensure the reproducibility of the system by delimitating the paper-based graphite electrode (PGE) area. The disposable PGE was fabricated by paint-brushing a conductive ink based on graphite powder and toluene-free PVC glue, onto a kraft paper. Different weight proportions (wt%) of graphite/PVC were evaluated regarding mechanical stability and electrochemical behavior. Cyclic voltammetric (CV) analysis in the presence of the [Fe(CN)6]3-/4- redox probe has shown that as the wt% of graphite in the ink increased from 50 to 90%, a clear decrease in peak potential separation (ΔEp) and increase in current are observed, indicating an improvement in charge transfer kinetics. However, 90 wt% graphite electrodes have shown poor adhesion to the substrate and easy leaching due to the small amount of PVC (binder). Therefore, the best PGE was achieved using 80:20 wt% graphite/PVC ink (PGE8020). Moreover, scanning electron microscopy (SEM) images and energy dispersive spectroscopy (EDS) mapping revealed a rugous and more uniform deposition of the conductive ink containing 80 wt% graphite. As a proof of concept, the graphite/PVC ink-based disposable electrodes were employed for the detection of 3-nitro-L-tyrosine (3-NLT) in synthetic urine samples, showing a detection limit of 2.85 μmol L-1, and %recovery in synthetic urine between 97 and 109%, highlighting the reliability and applicability of the proposed approach.
Collapse
Affiliation(s)
- Gleidson Thiago Sá Araújo
- Department of Chemistry - PPGQ, State University of Piauí, Campus Poeta Torquato Neto, Pirajá, Teresina, PI, 64002-150, Brazil
| | - Lucas Costa Faustino
- Department of Chemistry - PPGQ, Federal University of Piauí, Campus Universitário Ministro Petrônio Portella, Teresina, PI, 64049-550, Brazil
| | - Rejane Maria Pereira Silva
- Department of Chemistry - PPGQ, State University of Piauí, Campus Poeta Torquato Neto, Pirajá, Teresina, PI, 64002-150, Brazil
| | - Welter Cantanhêde
- Department of Chemistry - PPGQ, Federal University of Piauí, Campus Universitário Ministro Petrônio Portella, Teresina, PI, 64049-550, Brazil
| | - Everson Thiago Santos Gerôncio
- Department of Chemistry - PPGQ, State University of Piauí, Campus Poeta Torquato Neto, Pirajá, Teresina, PI, 64002-150, Brazil.
- Department of Chemistry - PPGQ, Federal University of Piauí, Campus Universitário Ministro Petrônio Portella, Teresina, PI, 64049-550, Brazil.
| |
Collapse
|
2
|
Zheng C, Liu R, Chen J, Li S, Ling Y, Zhang Z. Development of a selective electrochemical microsensor based on molecularly imprinted polydopamine/ZIF-67/laser-induced graphene for point-of-care determination of 3-nitrotyrosine. Biosens Bioelectron 2024; 255:116246. [PMID: 38537430 DOI: 10.1016/j.bios.2024.116246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 03/22/2024] [Accepted: 03/23/2024] [Indexed: 04/15/2024]
Abstract
3-nitrotyrosine (3-NT) is a biomarker closely associated with the early diagnosis of oxidative stress-related disorders. The development of an accurate, cost-effective, point-of-care 3-NT sensor holds significant importance for self-monitoring and clinical treatment. In this study, a selective, sensitive, and portable molecularly imprinted electrochemical sensor was developed. ZIF-67 with strong adsorption capacity was facilely modified on an electrochemically active laser-induced graphene (LIG) substrate (formed ZIF-67/LIG). Subsequently, biocompatible dopamine was chosen as the functional monomer, and interference-free ʟ-tyrosine was used as the dummy template to create molecularly imprinted polydopamine (MIPDA) on the ZIF-67/LIG, endowing the sensor with selectivity. The morphologies, electrochemical properties, and detection performance of the sensor were comprehensively investigated using scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry. To achieve the best performance, several parameters were optimized, including the number of polymerization cycles (15), elution time (60 min), incubation time (7 min), and pH of the buffer solution (6). The turnaround time for this sensor is 10 min. Benefiting from the alliance of MIPDA, ZIF-67, and LIG, the sensor exhibited excellent sensitivity with a detection limit of 6.71 nM, and distinguished selectivity against 11 interfering substances. To enable convenient clinical diagnosis, a customized electrochemical microsensor with MIPDA/ZIF-67/LIG was designed, showcasing excellent reliability and convenience in detecting biological samples without pretreatment. The proposed microsensor will not only facilitate clinical diagnosis and improve patient care, but also provide inspiration for the development of other portable and accurate electrochemical biosensors.
Collapse
Affiliation(s)
- Chibin Zheng
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| | - Ruwei Liu
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| | - Jianyue Chen
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China; Institute of New Functional Materials Co., Ltd, Guangxi Institute of Industrial Technology, Nanning, 530200, PR China
| | - Shilin Li
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| | - Yunhan Ling
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China.
| | - Zhengjun Zhang
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| |
Collapse
|
3
|
Anh NTN, Huynh TV, Nguyen VT, Nguyen TKA, Doong RA. MXene nanosheet-derived N, S-codoped graphene quantum dots for ultrasensitive and selective detection of 3-nitro-l-tyrosine in human serum. Anal Chim Acta 2024; 1292:342237. [PMID: 38309846 DOI: 10.1016/j.aca.2024.342237] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 02/05/2024]
Abstract
3-Nitro-l-tyrosine (3NT) is an oxidative stress metabolite associated with neurodegenerative diseases such as Parkinson's disease and rheumatoid arthritis. In this study, the N, S-co-doped graphene quantum dots (NSGQDs) derived from nitrogen-doped Ti3C2Tx MXene nanosheet via the hydrothermal method in the presence of mercaptosuccinic acid was synthesized as an optical sensing probe to detect 3NT in human serum. Tetramethyl ammonium hydroxide, the nitrogen source and delamination agent, was used to prepare nitrogen-doped MXene nanosheets via one step at room temperature. The as-prepared NSGQDs are uniform with an average size of 1.2 ± 0.6 nm, and can be stable in aqueous solution for at least 90 d to serve as the fluorescence probe. The N atoms in N-MXene reduce the restacking and aggregation of MXene nanosheets, while the sulfur dopant in NSGQDs increases the quantum yield from 6.2 to 12.1 % as well as enhances the selectivity of 3NT over the other 12 interferences via coordination interaction with nitro group in 3NT. A linear range of 0.02-150 μM in PBS and 0.05-200 μM in human serum with a recovery of 97-108 % for 3NT detection is observed. Moreover, the limit of detection can be lowered to 4.2 and 7 nM in PBS and 1 × diluted human serum, respectively. Results obtained clearly indicate the potential application of the N-Ti3C2Tx derived NSGQD for effective detection of 3NT, which can open a window for the synthesis of doped GQDs via 2D MXene materials for ultrasensitive and selective detection of other biometabolites and biomarkers of neurodegenerative diseases in biological fluids.
Collapse
Affiliation(s)
- Nguyen Thi Ngoc Anh
- Institute of Analytical and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan; Vinh Long University of Technology Education, 73 Nguyen Hue Street, Vinh Long City, Viet Nam
| | - Trung Viet Huynh
- Institute of Analytical and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan
| | - Van Thanh Nguyen
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan
| | - Thi Kim Anh Nguyen
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan
| | - Ruey-An Doong
- Institute of Analytical and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan.
| |
Collapse
|
4
|
Ayankojo AG, Reut J, Syritski V. Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics. BIOSENSORS 2024; 14:71. [PMID: 38391990 PMCID: PMC10886925 DOI: 10.3390/bios14020071] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 01/23/2024] [Accepted: 01/27/2024] [Indexed: 02/24/2024]
Abstract
Early-stage detection and diagnosis of diseases is essential to the prompt commencement of treatment regimens, curbing the spread of the disease, and improving human health. Thus, the accurate detection of disease biomarkers through the development of robust, sensitive, and selective diagnostic tools has remained cutting-edge scientific research for decades. Due to their merits of being selective, stable, simple, and having a low preparation cost, molecularly imprinted polymers (MIPs) are increasingly becoming artificial substitutes for natural receptors in the design of state-of-the-art sensing devices. While there are different MIP preparation approaches, electrochemical synthesis presents a unique and outstanding method for chemical sensing applications, allowing the direct formation of the polymer on the transducer as well as simplicity in tuning the film properties, thus accelerating the trend in the design of commercial MIP-based sensors. This review evaluates recent achievements in the applications of electrosynthesized MIP sensors for clinical analysis of disease biomarkers, identifying major trends and highlighting interesting perspectives on the realization of commercial MIP-endowed testing devices for rapid determination of prevailing diseases.
Collapse
Affiliation(s)
| | | | - Vitali Syritski
- Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia; (A.G.A.); (J.R.)
| |
Collapse
|
5
|
Sriram B, Kogularasu S, Wang SF, Chang-Chien GP. The Fabrication of a La 2Sn 2O 7/ f-HNT Composite for Non-Enzymatic Electrochemical Detection of 3-Nitro-l-tyrosine in Biological Samples. BIOSENSORS 2023; 13:722. [PMID: 37504120 PMCID: PMC10377610 DOI: 10.3390/bios13070722] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 07/03/2023] [Accepted: 07/07/2023] [Indexed: 07/29/2023]
Abstract
Reactive oxygen and nitrogen species (RONS), including 3-nitro-l-tyrosine, play a dual role in human health, inducing oxidative damage and regulating cellular functions. Early and accurate detection of such molecules, such as L-tyrosine in urine, can serve as critical biomarkers for various cancers. In this study, we aimed to enhance the electrochemical detection of these molecules through the synthesis of La2Sn2O7/f-HNT nanocomposites via a simple hydrothermal method. Detailed structural and morphological characterizations confirmed successful synthesis, consistent with our expected outcomes. The synthesized nanocomposites were utilized as nanocatalysts in electrochemical sensors, showing a notable limit of the detection of 0.012 µM for the real-time detection of 3-nitro-l-tyrosine. These findings underscore the potential of nanomaterial-based sensors in advancing early disease detection with high sensitivity, furthering our understanding of cellular oxidative processes.
Collapse
Affiliation(s)
- Balasubramanian Sriram
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 106, Taiwan
| | | | - Sea-Fue Wang
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 106, Taiwan
| | - Guo-Ping Chang-Chien
- Institute of Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833301, Taiwan
- Super Micro Mass Research and Technology Center, Cheng Shiu University, Kaohsiung 833301, Taiwan
- Center for Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833301, Taiwan
| |
Collapse
|
6
|
Yan Y, Liu Z, Xie P, Huang S, Chen J, Caddeo F, Liu X, Huang Q, Jin M, Shui L. Sensitive electrochemical assay of acetaminophen based on 3D-hierarchical mesoporous carbon nanosheets. J Colloid Interface Sci 2023; 634:509-520. [PMID: 36542979 DOI: 10.1016/j.jcis.2022.12.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/30/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022]
Abstract
Acetaminophen plays a key role in first-line Covid-19 cure as a supportive therapy of fever and pain. However, overdose of acetaminophen may give rise to severe adverse events such as acute liver failure in individual. In this work, 3D-hierarchical mesoporous carbon nanosheet (hMCNS) microspheres with superior properties were fabricated using simple and quick strategy and applied for sensitive quantification of acetaminophen in pharmaceutical formulation and rat plasmas after administration. The hMCNS microspheres are prepared via chemical etching of zinc oxide (ZnO) nanoparticles from a zinc-gallic acid precursor composite (Zn-GA) synthesized by high-temperature anaerobic pyrolysis. The obtained hMCNS could enhance analytes accessibility and accelerate proton transfer in the interface, hence increasing the electrochemical performance. Under optimized experimental conditions, the proposed electrochemical sensor achieves a detection limit of 3.5 nM for acetaminophen. The prepared electrochemical sensor has been successfully applied for quantification of acetaminophen in pharmaceutical formulations and the rat plasma samples before and after administration. Meanwhile, this sensor is compared with high-performance liquid chromatography (HPLC) as a reference technology, showing an excellent accuracy. Such an electrochemical sensor has great potential and economic benefits for applications in the fields of pharmaceutical assay and therapeutic drug monitoring (TDM).
Collapse
Affiliation(s)
- Yu Yan
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Zhenping Liu
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China; University of Hamburg, Institute for Nanostructure and Solid-State Physics, Center for Hybrid Nanostructures, Hamburg, Germany.
| | - Peng Xie
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Shuqing Huang
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Jiamei Chen
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Francesco Caddeo
- University of Hamburg, Institute for Nanostructure and Solid-State Physics, Center for Hybrid Nanostructures, Hamburg, Germany
| | - Xin Liu
- University of Hamburg, Institute for Nanostructure and Solid-State Physics, Center for Hybrid Nanostructures, Hamburg, Germany
| | - Qiuju Huang
- Guangxi Key Laboratory of Bioactive Molecules Research and Evaluation, College of Pharmacy, Guangxi Medical University, Nanning 530021, PR China
| | - Mingliang Jin
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China; International Academy of Optoelectronics at Zhaoqing, South China Normal University, Zhaoqing 526238, PR China
| | - Lingling Shui
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China; Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, South China Normal University, Guangzhou 510006, PR China.
| |
Collapse
|
7
|
Jamshidi M, Walcarius A, Thangamuthu M, Mehrgardi M, Ranjbar A. Electrochemical approaches based on micro- and nanomaterials for diagnosing oxidative stress. Mikrochim Acta 2023; 190:117. [PMID: 36879086 DOI: 10.1007/s00604-023-05681-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 01/30/2023] [Indexed: 03/08/2023]
Abstract
This review article comprehensively discusses the various electrochemical approaches for measuring and detecting oxidative stress biomarkers and enzymes, particularly reactive oxygen/nitrogen species, highly reactive chemical molecules, which are the byproducts of normal aerobic metabolism and can oxidize cellular components such as DNA, lipids, and proteins. First, we address the latest research on the electrochemical determination of reactive oxygen species generating enzymes, followed by detection of oxidative stress biomarkers, and final determination of total antioxidant activity (endogenous and exogenous). Most electrochemical sensing platforms exploited the unique properties of micro- and nanomaterials such as carbon nanomaterials, metal or metal oxide nanoparticles (NPs), conductive polymers and metal-nano compounds, which have been mainly used for enhancing the electrocatalytic response of sensors/biosensors. The performance of the electroanalytical devices commonly measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in terms of detection limit, sensitivity, and linear range of detection is also discussed. This article provides a comprehensive review of electrode fabrication, characterization and evaluation of their performances, which are assisting to design and manufacture an appropriate electrochemical (bio)sensor for medical and clinical applications. The key points such as accessibility, affordability, rapidity, low cost, and high sensitivity of the electrochemical sensing devices are also highlighted for the diagnosis of oxidative stress. Overall, this review brings a timely discussion on past and current approaches for developing electrochemical sensors and biosensors mainly based on micro and nanomaterials for the diagnosis of oxidative stress.
Collapse
Affiliation(s)
- Mahdi Jamshidi
- Department of Toxicology and Pharmacology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran.,Nutrition Health Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Alain Walcarius
- Laboratory of Physical Chemistry and Microbiology for Materials and the Environment, Université de Lorraine, CNRS, LCPME, Nancy, France
| | - Madasamy Thangamuthu
- Department of Chemical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Masoud Mehrgardi
- Department of Chemistry, University of Isfahan, Isfahan, 81746-73441, Iran
| | - Akram Ranjbar
- Department of Toxicology and Pharmacology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran. .,Nutrition Health Research Center, Hamadan University of Medical Sciences, Hamadan, Iran.
| |
Collapse
|
8
|
Ning L, Bai Y, Wang Z, Wen W, Wang J. Label-free electrochemiluminescence immunosensor based on conductive PANI to synergistically amplify electrodeposited AuNPs luminophore signal for ultrasensitive detection of 3-nitrotyrosine. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023]
|
9
|
Mehmandoust M, Soylak M, Erk N. Innovative molecularly imprinted electrochemical sensor for the nanomolar detection of Tenofovir as an anti-HIV drug. Talanta 2023; 253:123991. [PMID: 36228557 DOI: 10.1016/j.talanta.2022.123991] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/30/2022] [Accepted: 10/02/2022] [Indexed: 11/23/2022]
Abstract
Tenofovir (TNF) is an antiviral medicine that is utilized to treat the human immunodeficiency virus (HIV). However, its level must be controlled in the human body and environment at the risk of causing kidney and liver problems. Therefore, determining TNF concentration in real samples with more advanced, inexpensive, and accurate sensing systems is essential. In this work, a novel electrochemical nanosensor for TNF determination based on molecularly imprinted polymer (MIP) on the screen-printed electrode modified with functionalized multi-walled carbon nanotubes, graphite carbon nitride, and platinum nanoparticles (MIP-Pt@g-C3N4/F-MWCNT/SPE) was constructed through the electro-polymerization approach. The molecularly imprinted polymers were prepared on the electrode surface with TNF as the template molecule and 2-aminophenol (2-AP) as the functional monomer. Moreover, factors that affect sensor response were optimized. Pt@g-C3N4/F-MWCNT nanocomposite had an excellent synergistic effect on MIP, allowing rapid and specific identification of the test substance. The results demonstrated that the electro-polymerization of 2-AP supplies large amounts of functional groups for the binding of the template molecules, which remarkably enhances the sensitivity and specific surface area of the MIP sensor. This surface enlargement increased the analyte accessibility to imprinted molecular cavities. Under optimum conditions, the oxidation peak current had a linear relationship with TNF concentration ranging from 0.005 to 0.69 μM with a low detection limit of 0.0030 μM (S/N = 3). The results demonstrated that the designed MIP sensor possesses acceptable sensitivity, repeatability, and reproducibility toward TNF determination. Moreover, the developed sensor was applied to biological and water samples to determine TNF, and satisfactory recovery results of 95.6-104.8% were obtained (RSD less than 10.0%). We confirm that combining as-synthesized nanocomposite Pt@g-C3N4/F-MWCNT with MIP improves the limitations of MIP-based nanosensors. The proposed electrode is also compatible with portable potentiostats, allowing on-site measurements and showing tremendous promise as a point-of-care (POC) diagnostic platform.
Collapse
Affiliation(s)
- Mohammad Mehmandoust
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkey
| | - Mustafa Soylak
- Erciyes University, Faculty of Sciences, Department of Chemistry, 38039, Kayseri, Turkey; Technology Research & Application Center (TAUM), Erciyes University, 38039, Kayseri, Turkey; Turkish Academy of Sciences (TUBA), Cankaya, Ankara, Turkey
| | - Nevin Erk
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkey.
| |
Collapse
|
10
|
Ali HM, Hotan Alsohaimi I, Nayl A, Essawy AA, Gamal M, Ibrahim H. A new ultrasensitive platform based on f-GCNFs@nano-CeO2 core-shell nanocomposite for electrochemical sensing of oxidative stress biomarker 3-nitrotyrosine in presence of uric acid and tyrosine. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
11
|
Wang Q, Cheng S, Ren S, Zheng Z. Construction of molecularly imprinted voltammetric sensor based on Cu N C polyhedron porous carbon from Cu doping ZIF-8 for the selective determination of norfloxacin. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
12
|
Amatatongchai M, Nontawong N, Ngaosri P, Chunta S, Wanram S, Jarujamrus P, Nacapricha D, Lieberzeit PA. Facile and Compact Electrochemical Paper-Based Analytical Device for Point-of-Care Diagnostic of Dual Carcinogen Oxidative Stress Biomarkers through a Molecularly Imprinted Polymer Coated on Graphene Quantum-Dot Capped Gold. Anal Chem 2022; 94:16692-16700. [DOI: 10.1021/acs.analchem.2c03120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand
| | - Nongyao Nontawong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand
| | - Pattanun Ngaosri
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand
| | | | - Surasak Wanram
- Biomedical Science Research Unit, College of Medicine and Public Health, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand
| | - Purim Jarujamrus
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand
| | - Duangjai Nacapricha
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Peter A. Lieberzeit
- Faculty for Chemistry, Department of Physical Chemistry, University of Vienna, 1090 Vienna, Austria
| |
Collapse
|
13
|
Sriram B, Baby JN, Hsu YF, Wang SF, George M. In Situ Synthesis of a Bismuth Vanadate/Molybdenum Disulfide Composite: An Electrochemical Tool for 3-Nitro-l-Tyrosine Analysis. Inorg Chem 2022; 61:14046-14057. [PMID: 35998644 DOI: 10.1021/acs.inorgchem.2c02037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The quantification of 3-nitro-l-tyrosine (NO2-Tyr), an in vivo biomarker of nitrosative stress, is indispensable for the clinical intervention of various inflammatory disorders caused by nitrosative stress. By integrating the unique features of BiVO4 and MoS2 with matching bandgap energies, electrode materials with amplified response signals can be developed. In this regard, we introduce a hydrothermally synthesized bismuth vanadate sheathed molybdenum disulfide (MoS2@BiVO4) heterojunction as a highly sensitive electrode material for the determination of NO2-Tyr. Excellent electrochemical behavior perceived for the MoS2@BiVO4 augments the performance of the sensor and allows the measurement of NO2-Tyr in biological media without any time-consuming pretreatments. The synergistic interactions between BiVO4 and MoS2 heterojunctions contribute to low resistance charge transfer (Rct = 159.13 Ω·cm2), a reduction potential Epc = -0.58 V (vs Ag/AgCl), and a good response range (0.001-526.3 μM) with a lower limit of detection (0.94 nM) toward the detection of NO2-Tyr. An improved active surface area, reduced charge recombination, and high analyte adsorption contribute to the high loading of the biomarker for improved selectivity (in the presence of 10 interfering compounds), operational stability (1000 s), and reproducibility (six various modified electrodes). The proposed sensor was successfully utilized for the real-time determination of NO2-Tyr in water, urine, and saliva samples with good recovery values (±98.94-99.98%), ascertaining the reliability of the method. It is noteworthy that the electrochemical activity remains unaffected by other redox interferons, thus leading to targeted sensing applications.
Collapse
Affiliation(s)
- Balasubramanian Sriram
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 10608, Taiwan
| | - Jeena N Baby
- Department of Chemistry, Stella Maris College, Affiliated to the University of Madras, Chennai, Tamil Nadu 600086, India.,Department of Chemistry, St. Mary's College, Sulthan Bathery, Wayanad, Kerala 673592, India
| | - Yung-Fu Hsu
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 10608, Taiwan
| | - Sea-Fue Wang
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 10608, Taiwan
| | - Mary George
- Department of Chemistry, Stella Maris College, Affiliated to the University of Madras, Chennai, Tamil Nadu 600086, India
| |
Collapse
|
14
|
Aminikhah M, Babaei A, Taheri A. A novel electrochemical sensor based on molecularly imprinted polymer nanocomposite platform for sensitive and ultra-selective determination of citalopram. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
15
|
Heterostructures Based on Cobalt Phthalocyanine Films Decorated with Gold Nanoparticles for the Detection of Low Concentrations of Ammonia and Nitric Oxide. BIOSENSORS 2022; 12:bios12070476. [PMID: 35884279 PMCID: PMC9313448 DOI: 10.3390/bios12070476] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 06/20/2022] [Accepted: 06/27/2022] [Indexed: 11/25/2022]
Abstract
This work is aimed at the development of new heterostructures based on cobalt phthalocyanines (CoPc) and gold nanoparticles (AuNPs), and the evaluation of the prospects of their use to determine low concentrations of ammonia and nitric oxide. For this purpose, CoPc films were decorated with AuNPs by gas-phase methods (MOCVD and PVD) and drop-casting (DC), and their chemiresistive sensor response to low concentrations of NO (10–50 ppb) and NH3 (1–10 ppm) was investigated. A comparative analysis of the characteristics of heterostructures depending on the preparation methods was carried out. The composition, structure, and morphology of the resulting hybrid films were studied by X-ray photoelectron spectroscopy (XPS) and inductively coupled plasma atomic emission (ICP-AES) spectroscopy, as well as electron microscopy methods to discuss the effect of these parameters on the sensor response of hybrid films to ammonia and nitric oxide. It was shown that regardless of the fabrication method, the response of Au/CoPc heterostructures to NH3 and NO gases increased with an increase in the concentration of gold. The sensor response of Au/CoPc heterostructures to NH3 increased 2–3.3 times compared to CoPc film, whereas in the case of NO it increased up to 16 times. The detection limits of the Au/CoPc heterostructure with a gold content of ca. 2.1 µg/cm2 for NH3 and NO were 0.1 ppm and 4 ppb, respectively. It was shown that Au/CoPc heterostructures can be used for the detection of NH3 in a gas mixture simulating exhaled air (N2—74%, O2—16%, H2O—6%, CO2—4%).
Collapse
|
16
|
Molecularly Imprinted Polymer-Amyloid Fibril-Based Electrochemical Biosensor for Ultrasensitive Detection of Tryptophan. BIOSENSORS 2022; 12:bios12050291. [PMID: 35624592 PMCID: PMC9139163 DOI: 10.3390/bios12050291] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 04/25/2022] [Accepted: 04/29/2022] [Indexed: 12/03/2022]
Abstract
A tryptophan (Trp) sensor was investigated based on electrochemical impedance spectroscopy (EIS) of a molecularly imprinted polymer on a lysozyme amyloid fibril (MIP-AF). The MIP-AF was composed of aniline as a monomer chemically polymerized in the presence of a Trp template molecule onto the AF surface. After extracting the template molecule, the MIP-AF had cavities with a high affinity for the Trp molecules. The obtained MIP-AF demonstrated rapid Trp adsorption and substantial binding capacity (50 µM mg−1). Trp determination was studied using non-Faradaic EIS by drop drying the MIP-AF on the working electrode of a screen-printed electrode. The MIP-AF provided a large linear range (10 pM–80 µM), a low detection limit (8 pM), and high selectivity for Trp determination. Furthermore, the proposed method also indicates that the MIP-AF can be used to determine Trp in real samples such as milk and cancer cell media.
Collapse
|
17
|
Nehru R, Dong CD, Chen CW, Nguyen TB, Li MF. Green and low-cost synthesis of yttrium oxide/graphene oxide binary sheets as a highly efficient electrocatalyst for voltammetric determination of 3-nitro-L-tyrosine. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2021.128089] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
18
|
Nontawong N, Ngaosri P, Chunta S, Jarujamrus P, Nacapricha D, Lieberzeit PA, Amatatongchai M. Smart sensor for assessment of oxidative/nitrative stress biomarkers using a dual-imprinted electrochemical paper-based analytical device. Anal Chim Acta 2022; 1191:339363. [PMID: 35033235 DOI: 10.1016/j.aca.2021.339363] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/06/2021] [Accepted: 12/06/2021] [Indexed: 12/15/2022]
Abstract
We present a novel dual-imprinted electrochemical paper-based analytical device (Di-ePAD) to simultaneously determine 8-hydroxy-2'-deoxyguanosine (8-OHdG) and 3-nitrotyrosine (3-NT) and assess oxidative and nitrative biomarkers in urine and plasma samples. The Di-ePAD was designed with hydrophobic barrier layers formed on filter paper to provide three-dimensional circular reservoirs and assembled electrodes. The molecularly imprinted polymer (MIP) was synthesized using a silica nanosphere decorated with silver nanoparticles (SiO2@AgNPs) as a core covered with dual-analyte imprinted sites on the polymer to recognize selectively and bind the target biomarkers. This strategy drives monodispersity and enhances the conductivity of the resulting MIP core-shell products. 3-NT-MIP and 8-OHdG-MIP were synthesized by successively coating the surface of SiO2@AgNPs with l-Cysteine via the thiol group, then terminating with MIP shells. The dual imprinted core-shell composites possess attractive properties for the target biomarkers' sensing, including catalytic activity, selectivity, and good conductivity. The Di-ePAD revealed excellent linear dynamic ranges of 0.01-500 μM for 3-NT and 0.05-500 μM for 8-OHdG, with detection limits of 0.0027 μM for 3-NT and 0.0138 μM for 8-OHdG. This newly developed method based on the synergistic effects of SiO2@AgNPs combined with promising properties of MIP offers outstanding selectivity, sensitivity, reproducibility, simplicity, and low cost for quantitative analysis of 3-NT and 8-OHdG. The proposed Di-ePAD showed good accuracy and precision when applied to actual samples, including urine and serum samples validated by a conventional HPLC method.
Collapse
Affiliation(s)
- Nongyao Nontawong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Pattanun Ngaosri
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Suticha Chunta
- Faculty of Medical Technology, Prince of Songkla University, Songkhla, 90110, Thailand
| | - Purim Jarujamrus
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand
| | - Peter A Lieberzeit
- University of Vienna, Faculty for Chemistry, Department of Physical Chemistry, 1090, Vienna, Austria
| | - Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand.
| |
Collapse
|
19
|
An UiO-66/P-L-histidine composite film fabricated by electropolymerization and electrodeposition for sensing biomarker 4-nitroquinoline N-oxide. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106925] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
20
|
Ozcelikay G, Kaya S, Ozkan E, Cetinkaya A, Nemutlu E, Kır S, Ozkan S. Sensor-based MIP technologies for targeted metabolomics analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116487] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Mousazadeh M, Jahangiri-Manesh A, Nikkhah M, Abbasian S, Moshaii A, Masroor MJ, Norouzi P. Detection of hexanal gas as a volatile organic compound cancer biomarker using a nanocomposite of gold nanoparticles and selective polymers. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115962] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
22
|
Mustafa YL, Keirouz A, Leese HS. Molecularly Imprinted Polymers in Diagnostics: Accessing Analytes in Biofluids. J Mater Chem B 2022; 10:7418-7449. [DOI: 10.1039/d2tb00703g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Bio-applied molecularly imprinted polymers (MIPs) are biomimetic materials with tailor-made synthetic recognition sites, mimicking biological counterparts known for their sensitive and selective analyte detection. MIPs, specifically designed for biomarker analysis...
Collapse
|
23
|
Chen B, Xie Q, Zhang S, Lin L, Zhang Y, Zhang L, Jiang Y, Zhao M. A novel electrochemical molecularly imprinted senor based on CuCo2O4@ biomass derived carbon for sensitive detection of tryptophan. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115680] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
24
|
Garg M, Gupta A, Sharma AL, Singh S. Advancements in 2D Materials Based Biosensors for Oxidative Stress Biomarkers. ACS APPLIED BIO MATERIALS 2021; 4:5944-5960. [DOI: 10.1021/acsabm.1c00625] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Mayank Garg
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh 160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Arushi Gupta
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh 160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Amit L. Sharma
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh 160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Suman Singh
- CSIR- Central Scientific Instruments Organisation, Sector 30-C, Chandigarh 160030, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| |
Collapse
|
25
|
Li H, Zhu F, Xiang J, Wang F, Liu Q, Chen X. In situ growth of ZIF-8 on gold nanoparticles/magnetic carbon nanotubes for the electrochemical detection of bisphenol A. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2338-2344. [PMID: 33970976 DOI: 10.1039/d1ay00324k] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We herein report a facile and scalable strategy for the fabrication of a metal-organic framework (MOF) based composite by in situ growing ZIF-8 on gold nanoparticle (AuNP) loaded magnetic carbon nanotubes (mCNTs). AuNPs were firstly loaded on PEI (polyethylenimine) modified mCNTs by electrostatic forces, and then AuNPs/mCNTs were encapsulated into the ZIF-8 frame through in situ self-assembling of zinc ions and 2-methylimidazole. The morphology, spectroscopy and structural properties of the AuNP/mCNT@ZIF-8 nanocomposites were systematically characterized. The conductivity-strain tests revealed that the in situ insertion of AuNPs/mCNTs in ZIF-8 could not only shorten the electron transfer distance between active sites and mCNTs, but also increase the dispersion of mCNTs, which would benefit the electron and mass transfer. Besides, by adopting the AuNP/mCNT@ZIF-8 nanocomposite-modified glassy carbon electrode (GCE) as the working electrode, a novel electrochemical sensor was successfully developed for the detection of bisphenol A (BPA). A linear range of BPA detection from 1 μM to 100 μM with a limit of detection of 690 nM was favorably obtained. Moreover, the developed sensor exhibited satisfactory reproducibility and superior stability with excellent anti-interference ability, and was successfully applied in the detection of BPA in real samples.
Collapse
Affiliation(s)
- Hexiang Li
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China.
| | - Fawei Zhu
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China.
| | - Jun Xiang
- Hunan Institute of Food Quality Supervision Inspection and Research, The Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, Hunan, China
| | - Fangbin Wang
- Hunan Institute of Food Quality Supervision Inspection and Research, The Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, Hunan, China
| | - Qi Liu
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China. and Hunan Institute of Food Quality Supervision Inspection and Research, The Hunan Provincial Key Laboratory of Food Safety Monitoring and Early Warning, Changsha 410111, Hunan, China
| | - Xiaoqing Chen
- College of Chemistry and Chemical Engineering, Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Central South University, Changsha 410083, China.
| |
Collapse
|
26
|
Enzyme-free electrochemical sensor for the determination of hydrogen peroxide secreted from MCF-7 breast cancer cells using calcined indium metal-organic frameworks as efficient catalysts. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136962] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
27
|
Nascimento JAM, Nascimento ML, Mendes CHS, Oliveira SCB. Voltammetric Studies of 3‐Nitro‐tyrosine Electro‐oxidation at Solid Electrodes and its Interaction with DNA. ELECTROANAL 2020. [DOI: 10.1002/elan.202060256] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- José A. M. Nascimento
- Universidade Federal Rural de Pernambuco – UFRPE, Departamento de Química Recife-PE 52171-900 Brazil
| | - Maysa L. Nascimento
- Universidade Federal Rural de Pernambuco – UFRPE, Departamento de Química Recife-PE 52171-900 Brazil
| | - Carlos H. S. Mendes
- Universidade Federal Rural de Pernambuco – UFRPE, Departamento de Química Recife-PE 52171-900 Brazil
| | | |
Collapse
|
28
|
Electrochemical platform for the detection of adenosine using a sandwich-structured molecularly imprinted polymer-based sensor. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136656] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
29
|
Kaya SI, Karabulut TC, Kurbanoglu S, Ozkan SA. Chemically Modified Electrodes in Electrochemical Drug Analysis. CURR PHARM ANAL 2020. [DOI: 10.2174/1573412915666190304140433] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Electrode modification is a technique performed with different chemical and physical methods
using various materials, such as polymers, nanomaterials and biological agents in order to enhance
sensitivity, selectivity, stability and response of sensors. Modification provides the detection of small
amounts of analyte in a complex media with very low limit of detection values. Electrochemical methods
are well suited for drug analysis, and they are all-purpose techniques widely used in environmental
studies, industrial fields, and pharmaceutical and biomedical analyses. In this review, chemically modified
electrodes are discussed in terms of modification techniques and agents, and recent studies related
to chemically modified electrodes in electrochemical drug analysis are summarized.
Collapse
Affiliation(s)
- Sariye I. Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Tutku C. Karabulut
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sevinç Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
30
|
Martins GV, Marques AC, Fortunato E, Sales MGF. Paper-based (bio)sensor for label-free detection of 3-nitrotyrosine in human urine samples using molecular imprinted polymer. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100333] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
31
|
Kuzin YI, Padnya PL, Stoikov II, Gorbatchuk VV, Stoikov DI, Khadieva AI, Evtugyn GA. Electrochemical behavior of the monomeric and polymeric forms of N-phenyl-3-(phenylimino)-3H-phenothiazin-7-amine. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136195] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
32
|
Ju J, Liu X, Yu JJ, Sun K, Fathi F, Zeng X. Electrochemistry at Bimetallic Pd/Au Thin Film Surfaces for Selective Detection of Reactive Oxygen Species and Reactive Nitrogen Species. Anal Chem 2020; 92:6538-6547. [PMID: 32255342 DOI: 10.1021/acs.analchem.0c00140] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this work, we designed and fabricated Pd/Au bimetallic thin film electrodes with isolated Pd nanoparticles via underpotential deposition of copper on a gold substrate followed by in situ redox replace reaction in a Pd salt solution. The Pd/Au electrode was characterized by AFM and XPS as well as multiple electrochemical techniques including CV and electrochemical quartz crystal microbalance (EQCM) in sulfuric acid and phosphate buffer electrolytes. Results show that the reduction reactions of the analytes (i.e., H2O2 and 3-nitrotyrosine (3-NT)) at the Pd/Au thin film surfaces affect the nature and reactivity of Pd/Au surface electrochemistry including the adsorbed/absorbed hydrogen and/or the premonolayer palladium oxide redox processes at Pd. The EQCM experiment supports the arrangement of small size Pd nanoparticles in the Pd thin film in the presence of gold exhibits unusual properties, acting as a new physicochemical dimension between the electrode and target H2O2 and 3-NT molecules. The Pd/Au thin film was demonstrated as an extremely sensitive and selective probe for detection of common ROS and RNS (i.e., H2O2 and 3-NT). The integration of two different metallic species, Pd and Au, into a surface structure on nanoscale by exploiting their unique surface electrochemistry establishes an innovative analytical method for highly sensitive and selective detection of H2O2 and 3-NT simultaneously. This method has a general scope for detecting a broad range of redox active and nonredox active species simultaneously, which opens up new opportunities to develop new electrocatalytic materials and innovative sensing approaches.
Collapse
Affiliation(s)
- Jian Ju
- Department of Chemistry, Oakland University, Rochester, Michigan 48308, United States
| | - Xiaojun Liu
- Department of Chemistry, Oakland University, Rochester, Michigan 48308, United States
| | - Jing-Jiang Yu
- HiTACHI High Technologies America, Inc., Clarksburg, Maryland 20871, United States
| | - Kai Sun
- Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Fatemeh Fathi
- Department of Chemistry, Oakland University, Rochester, Michigan 48308, United States.,Department of Energy Engineering and Physics, Amirkabir University of Technology, 15875-4413 Tehran, Iran
| | - Xiangqun Zeng
- Department of Chemistry, Oakland University, Rochester, Michigan 48308, United States
| |
Collapse
|
33
|
Gui R, Guo H, Jin H. Preparation and applications of electrochemical chemosensors based on carbon-nanomaterial-modified molecularly imprinted polymers. NANOSCALE ADVANCES 2019; 1:3325-3363. [PMID: 36133548 PMCID: PMC9419493 DOI: 10.1039/c9na00455f] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 07/29/2019] [Indexed: 05/25/2023]
Abstract
The past few decades have witnessed a rapid development in electrochemical chemosensors (ECCSs). The integration of carbon nanomaterials (CNMs) and molecularly imprinted polymers (MIPs) has endowed ECCSs with high selectivity and sensitivity toward target detection. Due to the integrated merits of MIPs and CNMs, CNM-modified MIPs as ECCSs have been widely reported and have excellent detection applications. This review systematically summarized the general categories, preparation strategies, and applications of ECCSs based on CNM-modified MIPs. The categories include CNM-modified MIPs often hybridized with various materials and CNM-encapsulated or CNM-combined imprinting silica and polymers on working electrodes or other substrates. The preparation strategies include the polymerization of MIPs on CNM-modified substrates, co-polymerization of MIPs and CNMs on substrates, drop-casting of MIPs on CNM-modified substrates, self-assembly of CNMs/MIP complexes on substrates, and so forth. We discussed the in situ polymerization, electro-polymerization, and engineering structures of CNM-modified MIPs. With regard to potential applications, we elaborated the detection mechanisms, signal transducer modes, target types, and electrochemical sensing of targets in real samples. In addition, this review discussed the present status, challenges, and prospects of CNM-modified MIP-based ECCSs. This comprehensive review is desirable for scientists from broad research fields and can promote the further development of MIP-based functional materials, CNM-based hybrid materials, advanced composites, and hybrid materials.
Collapse
Affiliation(s)
- Rijun Gui
- College of Chemistry and Chemical Engineering, Intellectual Property Research Institute, Qingdao University Shandong 266071 PR China +86 532 85953981 +86 532 85953981
| | - Huijun Guo
- Advanced Fiber and Composites Research Institute, Jilin Institute of Chemical Technology Jilin 132022 PR China
| | - Hui Jin
- College of Chemistry and Chemical Engineering, Intellectual Property Research Institute, Qingdao University Shandong 266071 PR China +86 532 85953981 +86 532 85953981
| |
Collapse
|
34
|
Suprun EV. Protein post-translational modifications – A challenge for bioelectrochemistry. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.04.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
35
|
Bandookwala M, Thakkar D, Sengupta P. Advancements in the Analytical Quantification of Nitroxidative Stress Biomarker 3-Nitrotyrosine in Biological Matrices. Crit Rev Anal Chem 2019; 50:265-289. [DOI: 10.1080/10408347.2019.1623010] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Maria Bandookwala
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research-Ahmedabad, Gandhinagar, Gujarat, India
| | - Disha Thakkar
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research-Ahmedabad, Gandhinagar, Gujarat, India
| | - Pinaki Sengupta
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research-Ahmedabad, Gandhinagar, Gujarat, India
| |
Collapse
|
36
|
Ozcelikay G, Karadurmus L, Kaya SI, Bakirhan NK, Ozkan SA. A Review: New Trends in Electrode Systems for Sensitive Drug and Biomolecule Analysis. Crit Rev Anal Chem 2019; 50:212-225. [PMID: 31107105 DOI: 10.1080/10408347.2019.1615406] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Drug and biomolecule analysis with high precision, fast response, not expensive, and user-friendly methods have been very important for developing technology and clinical applications. Electrochemical methods are highly capable for assaying the concentration of electroactive drug or biomolecule and supply excellent knowledge concerning its physical and chemical properties such as electron transfer rates, diffusion coefficients, electron transfer number, and oxidation potential. Electrochemical methods have been widely applied because of their accuracy, sensitivity, cheapness, and can applied on-site determinations of various substances. The progress on electronics has allowed developing reliable, more sensitive and less expensive instrumentations, which have significant contribution in the area of drug development, drug and biomolecule analysis. The developing new sensors for electrochemical analysis of these compounds have growing interest in recent years. Screen-printed based electrodes have a great interest in electrochemical analysis of various drugs and biomolecules due to their easy manufacturing procedure of the electrode allow the transfer of electrochemical laboratory experiments for disposable on-site analysis of some compounds. Paper based electrodes are also fabricated by new technology. They can be preferred due to their easy, cheap, portable, disposable, and offering high sensitivity properties for many application field such as environmental monitoring, food quality control, clinical diagnosis, drug, and biomolecules analysis. In this review, the recent electrochemical drug and biomolecule (DNA, RNA, µRNA, Biomarkers, etc.) studies will be presented that involve new trend disposable electrodes.
Collapse
Affiliation(s)
- Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Leyla Karadurmus
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Faculty of Pharmacy, Adıyaman University, Adıyaman, Turkey
| | - S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Nurgul K Bakirhan
- Department of Chemistry, Arts & Sciences Faculty, Hitit University, Corum, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
37
|
Beluomini MA, da Silva JL, de Sá AC, Buffon E, Pereira TC, Stradiotto NR. Electrochemical sensors based on molecularly imprinted polymer on nanostructured carbon materials: A review. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.04.005] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
38
|
Essousi H, Barhoumi H, Jaffrezic‐Renault N. Molecularly Imprinted Electrochemical Sensor Based on Modified Reduced Graphene Oxide‐gold Nanoparticles‐polyaniline Nanocomposites Matrix for Dapsone Determination. ELECTROANAL 2019. [DOI: 10.1002/elan.201800818] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Houda Essousi
- University of MonastirFaculty of Sciences of MonastirLaboratory of Advanced Materials and Interfaces Monastir Tunisia
| | - Houcine Barhoumi
- University of MonastirFaculty of Sciences of MonastirLaboratory of Advanced Materials and Interfaces Monastir Tunisia
| | | |
Collapse
|
39
|
Florea A, Feier B, Cristea C. In situ analysis based on molecularly imprinted polymer electrochemical sensors. COMPREHENSIVE ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/bs.coac.2019.05.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
40
|
Lahcen AA, Amine A. Recent Advances in Electrochemical Sensors Based on Molecularly Imprinted Polymers and Nanomaterials. ELECTROANAL 2018. [DOI: 10.1002/elan.201800623] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Abdellatif Ait Lahcen
- Chemical Analysis & Biosensors Group; Laboratory of Process Engineering & Environment; Faculty of Science and Techniques; Hassan II University of Casablanca B.P. 146.; Mohammedia Morocco
| | - Aziz Amine
- Chemical Analysis & Biosensors Group; Laboratory of Process Engineering & Environment; Faculty of Science and Techniques; Hassan II University of Casablanca B.P. 146.; Mohammedia Morocco
| |
Collapse
|
41
|
An electrochemical chlorpyrifos aptasensor based on the use of a glassy carbon electrode modified with an electropolymerized aptamer-imprinted polymer and gold nanorods. Mikrochim Acta 2018; 185:551. [PMID: 30443812 DOI: 10.1007/s00604-018-3083-0] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Accepted: 11/05/2018] [Indexed: 12/12/2022]
Abstract
A highly selective and sensitive aptasensor is described for voltammetric determination of the pesticide chlorpyrifos (CPS). The sensor was constructed by modifying a glassy carbon electrode (GCE) with gold nanorods and a polymer that was molecularly imprinted with an aptamer against CPS. This results in double specific recognition. Under optimal conditions and a working potential as low as 0.22 V (vs. Ag/AgCl), the nanotools has a dynamic range that covers the 1.0 fM - 0.4 pM CPS concentration range, and the detection limit is 0.35 fM. This is lower than any of the previously reported methods. This MIP-aptasensor is selective over structural analogs, stable, and adequately reproducible. It was successfully applied to the determination of CPS in spiked food samples. Graphical abstract Impedimetric detection of Chlorpyrifos by using a Fe(CN)63-/4- probe based on double recognition of aptamer-molecular imprinted polymer onto a glassy carbon electrode modified with gold nanorod nanocomposite. The incubation with Chlorpyrifos lead to an increase of electron transfer resistance.
Collapse
|
42
|
Martins GV, Marques AC, Fortunato E, Sales MGF. Wax-printed paper-based device for direct electrochemical detection of 3-nitrotyrosine. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.07.150] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|