1
|
Brycht M, Skrzypek S, Mirceski V. Improved procedure for square-wave voltammetric sensing of fenhexamid residues on blueberries peel surface at the anodically pretreated boron-doped diamond electrode. Anal Chim Acta 2023; 1249:340936. [PMID: 36868771 DOI: 10.1016/j.aca.2023.340936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 01/18/2023] [Accepted: 02/01/2023] [Indexed: 02/05/2023]
Abstract
BACKGROUND Fungicide fenhexamid (FH) has a high residual concentration on fruits and vegetables, thus, it is of high importance to monitor the level of FH residues on foodstuff samples. So far, the assay of FH residues in selected foodstuff samples has been conducted by electroanalytical methods on sp2 carbon-based electrodes that are well-known to be susceptible to severe fouling of the electrodes surfaces during electrochemical measurements. As an alternative, sp3 carbon-based electrode such as boron-doped diamond (BDD) can be used in the analysis of FH residues retained on the peel surface of foodstuff (blueberries) sample. RESULTS In situ anodic pretreatment of the BDDE surface was found to be the most successful strategy to remediate the passivated BDDE surface by FH oxidation (by)products, and the best validation parameters, i.e., the widest linear range (3.0-100.0 μmol L-1), the highest sensitivity (0.0265 μA L μmol-1) and the lowest limit of detection (0.821 μmol L-1), were achieved on the anodically pretreated BDDE (APT-BDDE) in a Britton-Robinson buffer, pH 2.0, using square-wave voltammetry (SWV). The assay of FH residues retained on blueberries peel surface was performed on the APT-BDDE using SWV, and the obtained concentration of FH residues of 6.152 μmol L-1 (1.859 mg kg-1) was found to be below the maximum residue value fixed for blueberries by the European Union regulations (20 mg kg-1). SIGNIFICANCE AND NOVELTY In this work, a protocol based on a very easy and fast foodstuff sample preparation procedure combined with the straightforward pretreatment approach of the BDDE surface was elaborated for the first time for the monitoring of the level of FH residues retained on the peel surface of blueberries samples. The presented reliable, cost-effective, and easy-to-use protocol could find its application as a rapid screening method for the control of food safety.
Collapse
Affiliation(s)
- Mariola Brycht
- University of Lodz, Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, Tamka 12, 91-403, Lodz, Poland.
| | - Sławomira Skrzypek
- University of Lodz, Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, Tamka 12, 91-403, Lodz, Poland
| | - Valentin Mirceski
- University of Lodz, Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, Tamka 12, 91-403, Lodz, Poland; Ss. Cyril and Methodius University in Skopje, Faculty of Natural Sciences and Mathematics, Institute of Chemistry, Arhimedova 5, P.O. Box 162, 1001, Skopje, Macedonia; Macedonian Academy of Sciences and Arts, Research Center for Environment and Materials, Boulevard Krste Misirkov 2, 1000, Skopje, Macedonia
| |
Collapse
|
2
|
Gričar E, Kalcher K, Genorio B, Kolar M. Highly Sensitive Amperometric Detection of Hydrogen Peroxide in Saliva Based on N-Doped Graphene Nanoribbons and MnO 2 Modified Carbon Paste Electrodes. SENSORS 2021; 21:s21248301. [PMID: 34960395 PMCID: PMC8707399 DOI: 10.3390/s21248301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/06/2021] [Accepted: 12/10/2021] [Indexed: 11/27/2022]
Abstract
Four different graphene-based nanomaterials (htGO, N-htGO, htGONR, and N-htGONR) were synthesized, characterized, and used as a modifier of carbon paste electrode (CPE) in order to produce a reliable, precise, and highly sensitive non-enzymatic amperometric hydrogen peroxide sensor for complex matrices. CPE, with their robustness, reliability, and ease of modification, present a convenient starting point for the development of new sensors. Modification of CPE was optimized by systematically changing the type and concentration of materials in the modifier and studying the prepared electrode surface by cyclic voltammetry. N-htGONR in combination with manganese dioxide (1:1 ratio) proved to be the most appropriate material for detection of hydrogen peroxide in pharmaceutical and saliva matrices. The developed sensor exhibited a wide linear range (1.0–300 µM) and an excellent limit of detection (0.08 µM) and reproducibility, as well as high sensitivity and stability. The sensor was successfully applied to real sample analysis, where the recovery values for a commercially obtained pharmaceutical product were between 94.3% and 98.0%. Saliva samples of a user of the pharmaceutical product were also successfully analyzed.
Collapse
Affiliation(s)
- Ema Gričar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
| | - Kurt Kalcher
- Department of Analytical Chemistry, Insistute of Chemistry, University of Graz, Universitätsplatz 1, 8020 Graz, Austria;
| | - Boštjan Genorio
- Department of Chemical Engineering and Technical Safety, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia
- Correspondence: (B.G.); (M.K.)
| | - Mitja Kolar
- Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
- Correspondence: (B.G.); (M.K.)
| |
Collapse
|
3
|
Brahma B, Sen S, Sarkar P, Sarkar U. Interference-free electrocatalysis of p-chloro meta xylenol (PCMX) on uniquely designed optimized polymeric nanohybrid of P(EDOT-co-OPD) and fMWCNT modified glassy carbon electrode. Anal Chim Acta 2021; 1168:338595. [PMID: 34052000 DOI: 10.1016/j.aca.2021.338595] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 04/15/2021] [Accepted: 04/27/2021] [Indexed: 12/24/2022]
Abstract
p-Chloro-meta-Xylenol (PCMX) is an environmentally hazardous phenolic compound having biocidal and antiseptic activity. Very few research publications addressed monitoring this contaminant. This paper presents a rapid sensing system to quantify it in waste water samples. The electrochemical activity of PCMX was exploited through a unique polymeric nanocomposite modified transducer for its quantification. Poly[(3,4-Ethylenedioxythiophene)-co-(o-phenylenediamine)] [P(EDOT-co-OPD)] was deposited through one-step electropolymerization technique on the glassy carbon electrode (GCE) modified by functionalized multi-wall carbon nanotubes (fMWCNTs). An optimized combination of these constituents was evaluated using response surface methodology (RSM) based Box-Behnken experimental design. This maximized the response for PCMX using differential pulse voltammetry (DPV). The sensing matrix was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The structural and morphological study of the modified film was conducted by Fourier transform-infrared spectroscopy (FT-IR), Raman spectroscopy, scanning electron microscopy (SEM), and field emission scanning electron microscope (FESEM). The anodic peak current could be read from a wide range of 0.5-225 μM calibration curve with a detection limit of 0.2545 μmol L-1. Interestingly this work did not use any biomaterial in the modification but achieved interference-free response with excellent selectivity, sensitivity (0.4668 μA μM-1 cm-2), reproducibility (RSD = 2.2%), and repeatability. The sensing platform showed good stability (85.7%) of 3 months even after 150 times repetitive use. Its applicability for real samples was established by good correlation with standard methods.
Collapse
Affiliation(s)
- Bhanupriya Brahma
- Biosensor Laboratory, Department of Polymer Science and Technology, University of Calcutta, A.P.C. Road, Kolkata, 700009, West Bengal, India; Pollution Control Laboratory, Department of Chemical Engineering, Jadavpur University, 188, Raja Subodh Chandra Mallick Road, Kolkata, 700032, West Bengal, India.
| | - Sarani Sen
- Biosensor Laboratory, Department of Polymer Science and Technology, University of Calcutta, A.P.C. Road, Kolkata, 700009, West Bengal, India.
| | - Priyabrata Sarkar
- Biosensor Laboratory, Department of Polymer Science and Technology, University of Calcutta, A.P.C. Road, Kolkata, 700009, West Bengal, India; Calcutta Institute of Technology, Uluberia, Howrah, 711316, India.
| | - Ujjaini Sarkar
- Pollution Control Laboratory, Department of Chemical Engineering, Jadavpur University, 188, Raja Subodh Chandra Mallick Road, Kolkata, 700032, West Bengal, India.
| |
Collapse
|
4
|
Ma K, Zhou L, Bai Y, Xin Y, Chen M, Li H, Bao C, Zhou Y. Degradation and mechanism analysis of chloroxylenol in aqueous solution by gas-liquid discharge plasma combined with ozonation. RSC Adv 2021; 11:12907-12914. [PMID: 35423797 PMCID: PMC8697226 DOI: 10.1039/d1ra01886h] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 03/16/2021] [Indexed: 12/31/2022] Open
Abstract
Gas-liquid discharge non-thermal plasma (NTP) coupled with an ozonation reactor was used to investigate the removal of a broad-spectrum antibacterial agent, chloroxylenol (PCMX), from aqueous solution. Under the same experimental conditions (discharge power of 50.25 W, the initial concentration of PCMX of 60 mg L-1, oxygen flow of 1.0 L min-1 and PCMX solution flow of 150 mL min-1), the PCMX degradation rates in the ozonation-only, NTP-only and NTP/O3 systems were 29.25%, 67.04% and 79.43%, respectively. Correspondingly, the energy efficiency has also been greatly improved, and increased to 0.45, 1.03 and 1.21 g kW-1 h-1. In addition, the effects of the initial concentration of PCMX, initial pH, the flow rate of oxygen, the addition of H2O2 and the addition of a radical scavenger on the degradation rate of PCMX were investigated in the NTP/O3 system. The degradation rate in acidic solutions was higher than that in alkaline solutions. During the removal process of PCMX, the rate of degradation was strongly increased with the addition of H2O2 and acutely decreased with the addition of the radical scavenger. Compared with deionized water the degradation rates of PCMX in secondary effluent were inhibited. Four main intermediates of PCMX degradation by the NTP/O3 system were identified by gas chromatography-mass spectrometry (GC-MS) and a possible degradation pathway of PCMX was proposed. The changes in toxicity of the PCMX solution during the NTP/O3 system oxidation process were also evaluated using bioluminescent bacteria and Quantitative Structure Activity Relationship (QSAR) models with the help of the ECOSAR software.
Collapse
Affiliation(s)
- Keke Ma
- School of Environment, Tsinghua University Beijing 100084 P. R. China
| | - Lu Zhou
- School of Environment, Tsinghua University Beijing 100084 P. R. China
| | - Yu Bai
- School of Environment, Tsinghua University Beijing 100084 P. R. China
| | - Yiying Xin
- School of Environment, Tsinghua University Beijing 100084 P. R. China
| | - Mingru Chen
- School of Environment, Tsinghua University Beijing 100084 P. R. China
| | - Heping Li
- Department of Engineering Physics, Tsinghua University Beijing 100084 P. R. China
| | - Chengyu Bao
- Department of Engineering Physics, Tsinghua University Beijing 100084 P. R. China
| | - Yuexi Zhou
- School of Environment, Tsinghua University Beijing 100084 P. R. China
- Research Center of Environmental Pollution Control Engineering Technology, Chinese Research Academy of Environmental Sciences Beijing 100012 P. R. China
| |
Collapse
|
5
|
Brycht M, Konecka K, Sipa K, Skrzypek S, Mirčeski V. Electroanalysis of the Anthelmintic Drug Bithionol at Edge Plane Pyrolytic Graphite Electrode. ELECTROANAL 2019. [DOI: 10.1002/elan.201900322] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Mariola Brycht
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
- Charles University, Faculty of Science, Department of Analytical ChemistryUNESCO Laboratory of Environmental Electrochemistry Albertov 6 CZ-12843 Prague 2 Czech Republic
| | - Kinga Konecka
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
| | - Karolina Sipa
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
| | - Sławomira Skrzypek
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
| | - Valentin Mirčeski
- University of Lodz, Faculty of ChemistryDepartment of Inorganic and Analytical Chemistry Tamka 12 91-403 Lodz Poland
- Ss. Cyril and Methodius University, Faculty of Natural Sciences and MathematicsInstitute of Chemistry Arhimedova 5, P.O. Box 162 1001 Skopje R. Macedonia
| |
Collapse
|
6
|
The effect of the supporting electrolyte on the voltammetric determination of the veterinary drug nitroxinil. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.09.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|