1
|
Farid AR, Comtesse S, Sagi HC, Frosch KH, Weaver MJ, Yoon RS, von Keudell A. Enabling Technology in Fracture Surgery: State of the Art. J Bone Joint Surg Am 2025:00004623-990000000-01468. [PMID: 40424369 DOI: 10.2106/jbjs.24.00938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/29/2025]
Abstract
➢ Three-dimensional (3D) printing and virtual modeling, using computed tomographic (CT) scans as a base for the 3D-printed model, help surgeons to visualize relevant anatomy, may provide a better understanding of fracture planes, may help to plan surgical approaches, and can possibly simulate surgical fixation options.➢ Navigation systems create real-time 3D maps of patient anatomy intraoperatively, with most literature in orthopaedic trauma thus far demonstrating efficacy in percutaneous screw placement using preoperative imaging data or intraoperative markers.➢ Augmented reality and virtual reality are new applications in orthopaedic trauma, with the former in particular demonstrating the potential utility in intraoperative visualization of implant placement.➢ Use of 3D-printed metal implants has been studied in limited sample sizes thus far. However, early results have suggested that they may have good efficacy in improving intraoperative measures and postoperative outcomes.
Collapse
Affiliation(s)
- Alexander R Farid
- Harvard Combined Orthopaedic Residency Program, Boston, Massachusetts
| | - Simon Comtesse
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - H Claude Sagi
- Department of Orthopedic Surgery and Sports Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio
| | - Karl-Heinz Frosch
- Department of Trauma and Orthopedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Department of Trauma Surgery, Orthopedics and Sports Traumatology, BG Klinikum Hamburg, Hamburg, Germany
| | - Michael J Weaver
- Harvard Orthopaedic Trauma Initiative, Boston, Massachusetts
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Richard S Yoon
- Division of Orthopaedic Trauma and Adult Reconstruction, Department of Orthopaedic Surgery, Jersey City Medical Center/Saint Barnabas Medical Center-RWJBarnabas Health, Livingston/Jersey City, New Jersey
| | - Arvind von Keudell
- Harvard Orthopaedic Trauma Initiative, Boston, Massachusetts
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
- Department of Orthopaedic Surgery, Bispebjerg Hospital, University of Copenhagen, Denmark
| |
Collapse
|
2
|
Cody EA, Henry JK, Shaffrey I, Jones A, Nguyen JT, Demetracopoulos CA, Conti MS. Early Periprosthetic Tibial Lucency Following Low-Profile Total Ankle Arthroplasty. Foot Ankle Int 2025:10711007251324183. [PMID: 40100001 DOI: 10.1177/10711007251324183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/20/2025]
Abstract
BACKGROUND Most modern total ankle arthroplasty (TAA) implants have low-profile designs that minimize tibial resection and use small pegs or posts for fixation. A number of studies have identified concerning rates of lucencies around the tibial components of these implants. In this study, we evaluated a consecutive series of patients receiving an anterior approach low-profile TAA prosthesis to describe the incidence, characteristics, and progression of tibial component lucencies at short-term (minimum 1-year) follow-up. METHODS Patients who underwent primary TAA with a modern low-profile TAA tibial implant from 2014 through 2021 were identified from a prospectively collected TAA registry. Poorly defined lucency around the tibial component in all 4 tibial zones, as agreed on by 2 independent reviewers, was considered "global lucency." Intraoperative, 1-year, and 2-year postoperative radiographs were assessed for periprosthetic lucencies. Patients with global lucency at 1 year were compared to the remaining patients. RESULTS 554 ankles with a mean 29 ± 19 months of follow-up met inclusion criteria. Twenty-one ankles (3.8%) were revised for tibial loosening. Thirty-six ankles (6.5%) had global tibial lucency at 1 year. Of these, 15 (42%) were eventually revised and the remaining 21 (58%) were doing well clinically at final follow-up. Following multivariable regression, postoperative coronal tibiotalar offset ≥2 degrees (adjusted odds ratio [OR] = 3.60, P = .017), use of the Vantage implant (adjusted OR = 2.84, P = .006), and male sex (adjusted OR = 2.71, P = .016) were predictors of global lucency at 1 year. CONCLUSION At 1 year after anterior approach low-profile TAA, we found a 6.5% incidence of global lucency around the tibial component, suggestive of lack of osseous integration of the prosthesis. Fifty-eight percent of patients with global lucency did not require revision and were doing well clinically at early follow-up. Higher postoperative coronal tibiotalar offset, use of the Vantage implant, and male sex were all significantly associated with development of global lucency.
Collapse
Affiliation(s)
- Elizabeth A Cody
- Orthopedic Foot and Ankle Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Jensen K Henry
- Orthopedic Foot and Ankle Surgery, Hospital for Special Surgery, New York, NY, USA
| | | | - Agnes Jones
- Hospital for Special Surgery, New York, NY, USA
| | | | | | - Matthew S Conti
- Orthopedic Foot and Ankle Surgery, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
3
|
DeVries JG, Scharer BM. Rejection rate, modifications, and turnaround time for patient specific instrumentation plans in total ankle replacement. J Foot Ankle Surg 2025:S1067-2516(25)00063-8. [PMID: 40058684 DOI: 10.1053/j.jfas.2025.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Revised: 03/02/2025] [Accepted: 03/04/2025] [Indexed: 04/03/2025]
Abstract
Patient specific instrumentation (PSI) in total ankle replacement (TAR) has been reported to be accurate and time saving. However, there has been criticism regarding accuracy and an overreliance on the preoperative plan. This is a retrospective review of a single surgeon's PSI plans from 2016-2024. We report rejection rates, modifications, and turnaround time. A total of 101 plans were reviewed and found an overall rejection rate of 17.8 %, with 18 reports rejected. Average turnaround time was 29:07 hours. When comparing the 1st half of the study period to the second half, a statistically significant increase in rejection rate was found, 0 % to 45 %, p < 0.0001. In addition, there was a higher rate of rejection on more complicated stemmed implants or revision implants compared to low profile implants. This report shows there is not a blind trust of the engineer's plan, and with experience with PSI rejection rate increases. Also, the engineer's understanding of complicated cases is addressed with higher rates of rejection in complicated cases. This report refutes charges that surgeons that use PSI for TAR are overly reliant on CT-derived engineer produced plans. Further studies with national data or multiple surgeons should be undertaken to explore this further.
Collapse
Affiliation(s)
- Jason George DeVries
- Orthopedics & Sports Medicine, BayCare Clinic, 1111 BayShore Dr, Manitowoc, WI 54220, United States.
| | - Brandon M Scharer
- Orthopedics & Sports Medicine, BayCare Clinic, 1111 BayShore Dr, Manitowoc, WI 54220, United States
| |
Collapse
|
4
|
Padilla JA, Andriani N, Papalia A, Huyke-Hernández FA, Cohn RM, Bitterman AD. Response to "Letter Regarding: Cost Analysis of Routine Histopathologic Evaluation of Specimens Following Total Ankle Arthroplasty". Foot Ankle Int 2025; 46:127-128. [PMID: 39748475 DOI: 10.1177/10711007241308244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
5
|
Regal A, Tuifua TS, Scharer BM, DeVries JG. Effect of Preoperative Coronal Plane Alignment on Actual Versus Predicted Alignment Using Patient Specific Instrumentation in Total Ankle Replacement. J Foot Ankle Surg 2024; 63:724-730. [PMID: 39098649 DOI: 10.1053/j.jfas.2024.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 06/24/2024] [Accepted: 07/25/2024] [Indexed: 08/06/2024]
Abstract
Alignment in total ankle replacement is important for success and implant survival. Recently there has been the introduction and adoption of patient specific instrumentation for implantation in total ankle replacement. Current literature does not evaluate the effect of preoperative deformity on accuracy of patient specific instrumentation. A retrospective radiographic analysis was performed on 97 consecutive patients receiving total ankle replacement with patient specific instrumentation to assess the accuracy and reproducibility of the instrumentation. Subgroup analysis evaluated the effect of preoperative deformity. All surgeries were performed by fellowship trained foot and ankle surgeons without industry ties to the implants used. Preoperative and postoperative films were compared to plans based on computerized tomography scans to assess how closely the plan would be implemented in patients. Overall postoperative coronal plane alignment was within 2° of predicted in 87.6% (85 patients). Similarly, overall postoperative sagittal plane alignment was within 2° of predicted in 88.7% (86 patients). Tibial implant size was accurately predicted in 81.4% (79 patients), and talus implant size was correct in 75.3% (73 patients). Patients with preoperative varus deformity had a higher difference between predicted and actual postoperative alignment compared to valgus deformity (1.1° compared to 0.3°, p = .02). A higher average procedure time was found in varus patients, and more adjunctive procedures were needed in patients with varus or valgus deformity, but these were not significant, p > .5. Surgeons can expect a high degree of accuracy when using patient specific instrumentation overall, but less accurate in varus deformity.
Collapse
Affiliation(s)
- Andrew Regal
- Podiatric Medicine and Surgery Residency, Ascension Wisconsin Hospital, Milwaukee, WI.
| | - Tisileli S Tuifua
- Radiology Department, Aurora St. Luke's Medical Center, Milwaukee, WI
| | | | | |
Collapse
|
6
|
Teehan E, Demetracopoulos C. Outcomes of Total Ankle Replacement. Orthop Clin North Am 2024; 55:503-512. [PMID: 39216955 DOI: 10.1016/j.ocl.2024.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
Total ankle replacement (TAR) is an effective operative treatment of end-stage ankle osteoarthritis (OA) in the appropriate patient, conferring improved kinematic function, decreased stress across adjacent joints, and offering equivalent pain relief in comparison to ankle arthrodesis (AA). It is important to consider patient age, weight, coronal tibiotalar deformity, joint line height, and adjacent joint OA to maximize clinical and patient outcomes. Both mobile-bearing and fixed-bearing implants have demonstrated favorable clinical outcomes, marked improvement in patient-reported outcomes, and good survivorship; however, implant survivorship decreases with longer term follow-up, necessitating constant improvement of primary and revision TAR options.
Collapse
Affiliation(s)
- Emily Teehan
- Foot & Ankle Service, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA
| | | |
Collapse
|
7
|
de Carvalho KAM, Barbachan Mansur NS, DaCosta A, Godoy-Santos AL, de Cesar Netto C. Cone-Beam Weight-Bearing Computed Tomography of Ankle Arthritis and Total Ankle Arthroplasty. Clin Podiatr Med Surg 2024; 41:665-684. [PMID: 39237178 DOI: 10.1016/j.cpm.2024.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
Weight-bearing computed tomography has multiple advantages in evaluating the hindfoot and ankle. It can assess hindfoot and ankle alignment, pathology in ankle arthritis, and complications related to total ankle replacements. It is an essential tool in ankle osteoarthritis diagnostic, preoperative planning, and total ankle replacement outcomes. It allows for better accuracy and reproducibility of alignment and implant size. In addition, it has the potential to more assertively detect complications related to weight bearing.
Collapse
Affiliation(s)
| | | | - Albert DaCosta
- Department of Orthopedic Surgery (IOT), Division of Foot and Ankle, University of São Paulo (USP), São Paulo-SP, Brazil
| | - Alexandre Leme Godoy-Santos
- Department of Orthopedic Surgery (IOT), Division of Foot and Ankle, University of São Paulo (USP), São Paulo-SP, Brazil
| | - Cesar de Cesar Netto
- Department of Orthopedic Surgery, Division of Foot and Ankle, Duke University, Durham-NC, USA.
| |
Collapse
|
8
|
Arceri A, Abdi P, Mazzotti A, Zielli SO, Artioli E, Langone L, Sgubbi F, Faldini C. Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study. J Pers Med 2024; 14:770. [PMID: 39064024 PMCID: PMC11278035 DOI: 10.3390/jpm14070770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 07/06/2024] [Accepted: 07/13/2024] [Indexed: 07/28/2024] Open
Abstract
PURPOSE This retrospective study aims to compare surgical outcomes between two cohorts of patients who underwent total ankle arthroplasty (TAA) using either standard technique or patient-specific instrumentation (PSI). METHODS A consecutive series of patients who affected of end-staged ankle osteoarthritis were retrospectively assessed and divided into two groups based on TAA techniques: a TAA standard technique group and a TAA-using PSI group. The two groups were compared in terms of operative time, additional procedures, complications (neurovascular and wound problems, infection, loosening and osteolysis, revision and explantation rates, and perioperative fracture), clinical scores, and range of motion (ROM). RESULT Fifty-one patients underwent standard TAA, while 13 patients underwent TAA with PSI. At 1-year follow-up, there were no significant differences in complication rates between the two groups (p > 0.05). AOFAS scores were similar, with the standard TAA group scoring 83.33 ± 7.55 and the PSI group scoring 82.92 ± 9.7 (p = 0.870). Likewise, the postoperative ROM did not differ significantly, with 15.12 ± 7.6 degrees for the standard TAA group and 16.05 ± 6.7 degrees for the PSI group (p = 0.689). However, the standard TAA group experienced significantly longer operative time (107.1 ± 22.1 min) compared to the PSI group (91.92 ± 22.9 min, p = 0.032). Additionally, the standard TAA group required more adjunctive procedures (29.7%) compared to the PSI group (7.7%, p = 0.04). Residual pain was also more frequently reported in the standard TAA group (62.7%) than in the PSI group (30.7%, p = 0.038). CONCLUSION While both techniques resulted in comparable complication rates, clinical scores and ROM, the PSI group reported significantly shorter operative time and less residual pain, thus requiring fewer postoperative procedures.
Collapse
Affiliation(s)
- Alberto Arceri
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Pejman Abdi
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Antonio Mazzotti
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy
| | - Simone Ottavio Zielli
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Elena Artioli
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Laura Langone
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Federico Sgubbi
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
| | - Cesare Faldini
- 1st Orthopaedics and Traumatologic Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (A.A.); (P.A.); (S.O.Z.); (E.A.); (L.L.); (F.S.); (C.F.)
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy
| |
Collapse
|
9
|
Mazzotti A, Zielli SO, Arceri A, Artioli E, Langone L, Sgubbi F, Geraci G, Faldini C. Accuracy of patient-specific instrumentation for implant positioning in custom-made total ankle arthroplasty. J Exp Orthop 2024; 11:e12026. [PMID: 39072244 PMCID: PMC11272990 DOI: 10.1002/jeo2.12026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 03/04/2024] [Accepted: 03/25/2024] [Indexed: 07/30/2024] Open
Abstract
Purpose This retrospective radiological analysis aimed to assess the accuracy of implant positioning in patients with ankle arthritis undergoing custom-made total ankle arthroplasty (TAA) with patient-specific instrumentation (PSI) compared with preoperative planning. Methods Patients who underwent custom-made TAA with PSI from January 2018 to March 2023 were retrospectively evaluated, focusing on the tibial anterior surface (TAS) angle, tibial lateral surface (TLS) angle and tibiotalar ratio (TTR). Additionally, data regarding the time from the preoperative computed tomography (CT) scan to surgery, associated procedures and complications were recorded. Results No associated procedures were performed, and only one intraoperative complication, an iatrogenic lateral malleolar fracture, was recorded. In the coronal plane, custom-made TAA with PSI consistently achieved precise positioning of prosthetic components, even in cases with significant preoperative deformities or bone deficits. However, a statistically significant deviation from the planned values was observed in the sagittal plane (p = 0.007). A notable correlation was identified between the time elapsed from the preoperative CT scan to surgery and the deviation from the planned to the actual postoperative TAS angle (p < 0.001). Conclusion This study underscores the efficacy of PSI systems in achieving precise positioning in the coronal plane, in accordance with preoperative planning. In contrast, sagittal plane positioning did not demonstrate the same level of accuracy, as evidenced by a statistically significant difference between the planned and postoperative TLS values. Nevertheless, all measurements remained within the recommended range according to the existing literature. Level of Evidence Level IV.
Collapse
Affiliation(s)
- Antonio Mazzotti
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Simone Ottavio Zielli
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Alberto Arceri
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Elena Artioli
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Laura Langone
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Federico Sgubbi
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Giuseppe Geraci
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| | - Cesare Faldini
- IRCCS Istituto Ortopedico Rizzoli1st Orthopaedics and Traumatologic ClinicBolognaItaly
- Department of Biomedical and Neuromotor Sciences (DIBINEM)Alma Mater Studiorum University of BolognaBolognaItaly
| |
Collapse
|
10
|
Duff J, Dunson J, Doty JF. Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up. Foot Ankle Surg 2024; 30:382-388. [PMID: 38453589 DOI: 10.1016/j.fas.2024.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/16/2024] [Accepted: 02/22/2024] [Indexed: 03/09/2024]
Abstract
BACKGROUND This is a pilot study reviewing patients undergoing ankle replacement with the 3-D printed INFINITY™ with ADAPTIS™ total ankle arthroplasty (TAA) system. METHODS A retrospective review was conducted of patients with a minimum two-year follow-up who underwent TAA with the INFINITY™ with ADAPTIS™ implant system. Outcome measures include implant survivorship, complications with subsequent reoperations, patient reported outcomes, and radiologic subsidence or radiolucency. RESULTS Thirty patients were included with median follow-up of 26 months (range, 24-36). Implant survival rate was 90% (27/30). Two patients experienced linear radiolucency > 2 mm: one required a revision TAA secondary to tibial subsidence; the other patient was asymptomatic and nonprogressive on serial radiographs. No cystic radiolucencies > 5 mm were identified. VAS, PROMIS PF, and FADI scores improved significantly. CONCLUSION TAA performed with the 3-D printed INFINITY™ with ADAPTIS™ implant technology led to ninety percent short term implant survivorship and improvement in patient reported outcomes with comparable results to other 4th generation arthroplasty systems as a treatment modality for end-stage ankle arthritis. LEVEL OF EVIDENCE Level III, Retrospective cohort study, Prognostic.
Collapse
Affiliation(s)
- Joseph Duff
- Department of Orthopaedic Surgery, University of Tennessee College of Medicine Chattanooga, 975 East Third Street, Hospital Box 260, Chattanooga, TN 37403, USA.
| | - Jordan Dunson
- Department of Orthopaedic Surgery, University of Tennessee College of Medicine Chattanooga, 975 East Third Street, Hospital Box 260, Chattanooga, TN 37403, USA
| | - Jesse F Doty
- Department of Orthopaedic Surgery, University of Tennessee College of Medicine Chattanooga, 975 East Third Street, Hospital Box 260, Chattanooga, TN 37403, USA
| |
Collapse
|
11
|
Doty J, Murphy GA, Bohay D, Fortin P, Vora A, Strasser N, Friscia D, Newton W, Gross CE. Two-Year Survivorship and Patient-Reported Outcomes of a Prospectively Enrolled Cohort of INFINITY Total Ankle Arthroplasties. Foot Ankle Int 2024; 45:150-157. [PMID: 38140701 DOI: 10.1177/10711007231212484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
BACKGROUND The INFINITY total ankle implant is a widely and successfully used option for total ankle arthroplasty. The purpose of this study is to assess the 2-year survivorship, complication rates, patient-reported outcomes, and radiologic findings of prospectively enrolled patients undergoing a fixed-bearing total ankle arthroplasty (TAA). This study sought to determine if factors such as traditional vs patient-specific instrumentation, preoperative degree of arthritis, deformity, or etiology of arthritis impact surgical or clinical outcomes. METHODS A total of 143 prospectively enrolled patients (148 ankles) underwent TAA with a fixed-bearing total ankle implant between 2017 and 2019 at 9 different institutions by 9 different surgeons. A total of 116 completed 2-year follow-up. Patients were stratified by instrumentation used, degree of preoperative deformity, the Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system, and etiology of arthritis. Outcomes used included implant survivorship and adverse events within 2 years of surgery. Additionally, patient-reported outcomes and radiographs were collected at 6-month, 1-year, and 2-year postoperatively. PROMs used included Ankle Osteoarthritis Score (AOS), Patient-Reported Outcomes Measurement Information System (PROMIS) global health score, the Foot and Ankle Outcome Score (FAOS), and patient satisfaction (rated from excellent to poor). RESULTS Implant survivorship at 2 years was 97.79%. There were 17 reoperations (11.5%), with 4 of the implants requiring revision (2.7%). Significant improvements in all PROMs were observed among all subgroups at all postoperative time points without significant variation between subgroups. Patients classified as COFAS type 2 arthritis preoperatively demonstrated significantly more improvement in FAOS Total Symptom Score at the 1- and 2-year measurements than COFAS type 3 patients at both time points. CONCLUSION Total ankle arthroplasty with a fixed-bearing implant system is a safe and reliable treatment option for patients with end-stage arthritis regardless of degree of deformity or COFAS grading. LEVEL OF EVIDENCE Level II, prospective cohort study.
Collapse
Affiliation(s)
- Jesse Doty
- University of Tennessee/Erlanger Orthopaedics, Chattanooga, TN, USA
| | | | - Donald Bohay
- Orthopaedics Associates of Michigan, Grand Rapids, MI, USA
| | - Paul Fortin
- Michigan Orthopaedic Surgeons, Beaumont Hospital Royal Oak, MI, USA
| | - Anand Vora
- Illinois Bone & Joint Institute, Chicago, IL, USA
| | | | - David Friscia
- Eisenhower Desert Orthopaedic Center, Rancho Mirage, CA, USA
| | - William Newton
- Medical University of South Carolina, Charleston, SC, USA
| | | |
Collapse
|
12
|
Yau J, Emmerson B, Kakwani R, Murty AN, Townshend DN. Patient-Reported Outcomes in Total Ankle Arthroplasty: Patient Specific Versus Standard Instrumentation. Foot Ankle Spec 2024; 17:30S-37S. [PMID: 37350251 PMCID: PMC11016196 DOI: 10.1177/19386400231179124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) can now be performed using patient-specific instrumentation (PSI). Advantages include the ability to preoperatively plan and reduce the number of intraoperative surgical steps. The aim of this study was to compare PSI with standard instrumentation (SI) in a nonrandomized retrospective cohort study with respect to patient-reported outcome measures (PROMs). Secondary aims were to compare complications, reoperations, tourniquet time, fluoroscopy time, and postoperative alignment. METHODS In all, 159 patients (111 men, 48 women) undergoing a total of 168 Infinity TAA (Stryker, Memphis, TN) using PSI (Prophecy, Stryker, Memphis, TN) or SI between 2014 and 2021 were included with a minimum follow-up of 12 months. The PROMs were obtained preoperatively and at 1 year, and included the Manchester-Oxford Foot Questionnaire (MOXFQ), Ankle Osteoarthritis Scale (AOS), and European Quality of Life 5 Dimension 3 Level (EQ-5D-3L). Coronal plane deformity correction was assessed using the midline tibiotalar angle (MTTA). Demographics, tourniquet time, and intraoperative fluoroscopy times were obtained from the hospital records. RESULTS There were 61 TAAs in the PSI group and 107 TAAs in the SI group. There was no significant difference in total MOXFQ, AOS, or EQ-5D. There was a significantly reduced tourniquet time (PSI mean: 95.39 minutes, SI mean: 116.87 minutes, P < .001) and radiation exposure (PSI mean: 31 seconds, SI mean: 53 seconds, P < .001). Angular correction was more accurate in the PSI group (PSI mean: 1.29°, SI mean: 2.26°, P = .005). CONCLUSION This study supports the use of PSI to decrease operative time, reduce intraoperative fluoroscopy, improve accuracy of implantation, and improve postoperative alignment in TAA. There was a significant difference (P = .032) in favor of PSI in the walking/standing domain of the MOXFQ at 12 months but no significant difference in overall PROMs. LEVELS OF EVIDENCE Level III, Retrospective.
Collapse
Affiliation(s)
- James Yau
- Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK
| | | | - Rajesh Kakwani
- Northumbria Healthcare NHS Foundation Trust, North Shields, UK
| | | | - David N. Townshend
- Northumbria Healthcare NHS Foundation Trust, North Shields, UK
- University of Newcastle upon Tyne, Newcastle upon Tyne, UK
| |
Collapse
|
13
|
Townshend D, Bing A, Blundell C, Clough T, Davenport J, Davies H, Davis J, Dhar S, Hepple S, Kakwani R, Karski M, Makwana N, McKinley J, Murty A, Raglan M, Shalaby H, Sharpe I, Smith R, Taylor H, Goldberg A. Two to Five-Year Outcomes of Total Ankle Arthroplasty with the Infinity Fixed-Bearing Implant: A Concise Follow-up of a Previous Report. J Bone Joint Surg Am 2023; 105:1846-1856. [PMID: 38063779 PMCID: PMC10695343 DOI: 10.2106/jbjs.22.01294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
LEVEL OF EVIDENCE Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- David Townshend
- Northumbria NHS Healthcare Trust, North Shields, England, United Kingdom
| | - Andrew Bing
- Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Trust, Oswestry, England, United Kingdom
| | | | - Tim Clough
- Wrightington Hospital, Wrightington, United Kingdom
| | | | - Howard Davies
- Northern General Hospital, Sheffield, United Kingdom
| | | | - Sunil Dhar
- Nottingham University Hospitals Trust, Nottingham, United Kingdom
| | - Steve Hepple
- Avon Orthopaedic Centre, Southmead Hospital, Bristol, United Kingdom
| | - Rajesh Kakwani
- Northumbria NHS Healthcare Trust, North Shields, England, United Kingdom
| | - Mike Karski
- Wrightington Hospital, Wrightington, United Kingdom
| | - Nilesh Makwana
- Robert Jones and Agnes Hunt Orthopaedic Hospital, NHS Trust, Oswestry, England, United Kingdom
| | | | - Aradhyula Murty
- Northumbria NHS Healthcare Trust, North Shields, England, United Kingdom
| | - Martin Raglan
- Nottingham University Hospitals Trust, Nottingham, United Kingdom
| | | | - Ian Sharpe
- Royal Devon and Exeter NHS Foundation Trust, Exeter, United Kingdom
| | - Robert Smith
- Wrightington Hospital, Wrightington, United Kingdom
| | - Heath Taylor
- Royal Bournemouth Hospital, Bournemouth, United Kingdom
| | | |
Collapse
|
14
|
Mathieu J, Dagneaux L. Midfoot Tarsectomy in Cavovarus: Why PSI Makes a Difference? Foot Ankle Clin 2023; 28:791-803. [PMID: 37863535 DOI: 10.1016/j.fcl.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2023]
Abstract
The cavovarus foot is a complex deformity that can be treated using multiple surgical procedures, ranging from soft tissue surgery to triple arthrodesis. Among these options, anterior midfoot tarsectomy is a three-dimensional closed-wedge osteotomy, traditionally performed slowly and progressively in a blind fashion, and remaining a challenge for unexperimented surgeons with variable outcomes. As such, we investigated and discussed the use of patient-specific cutting guides (PSCGs) in computer-assisted anterior midfoot tarsectomy in terms of accuracy, reproducibility, and safety.
Collapse
Affiliation(s)
- Julie Mathieu
- Department of Orthopedic Surgery, Lower Limb Surgery Unit, Univ Montpellier, 371 av. Gaston Giraud, Montpellier Cedex 05 34295, France
| | - Louis Dagneaux
- Department of Orthopedic Surgery, Lower Limb Surgery Unit, Univ Montpellier, 371 av. Gaston Giraud, Montpellier Cedex 05 34295, France; Laboratoire de mécanique et génie civil (LMGC), CNRS, Montpellier University of Excellence (MUSE), 860, rue de St-Priest, Montpellier 34090, France.
| |
Collapse
|
15
|
April PM, Locke E, Champagne PH, Angers M, Martinez-Gomez AP, Seidel A, Jibri Z, Lalonde KA, Meulenkamp B. Accuracy of a Patient-Specific Total Ankle Arthroplasty Instrumentation. Foot Ankle Int 2023; 44:1150-1157. [PMID: 37727986 DOI: 10.1177/10711007231194049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Total ankle arthroplasty (TAA) is a preferred surgical option for end-stage ankle osteoarthritis; however, it is a demanding procedure with a higher historical rate of revision compared with ankle fusion. Patient-specific instrumentation (PSI) has been introduced to optimize prosthesis alignment and theoretically overall improve TAA outcomes. The goal of this study is to report on the experience and surgical outcomes of one implant with specific evaluation of the accuracy and reproducibility of the system with respect to prosthesis alignment and prediction of implant size. METHODS A retrospective, multicentered study involving 4 foot and ankle fellowship-trained orthopaedic surgeon's patients undergoing TAA between January 1, 2015, and December 31, 2018, using the PROPHECY PSI system. RESULTS 80 TAA procedures were performed. On average the postoperative tibial component alignment was 89.9 (range, 86.1-96.5) degrees in the coronal plane, with a mean sagittal alignment of 88.1 (range, 81.3-96.7) degrees. The mean deviation from neutral sagittal alignment improved from 4.9 ± 3.9 degrees preoperatively to 2.7 ± 1.7 degrees postoperatively, whereas the mean coronal alignment improved from 3.3 ± 2.5 degrees to 1.3 ± 1.1 degrees. The PSI software correctly determined the tibial implant size in 70 patients (89%). Prediction of talar implant sizing was less accurate than the tibial component, with 56 patients (71%) using the predicted sized implant. The overall implant survival at a mean follow-up of 45 months (range, 27-76) was 97.5%. CONCLUSION We found that this PSI system accurately and reliably assisted in implant total ankle prosthesis positioning within a clinically acceptable margin and without significant outliers. Prediction of implant size was not as accurate as component orientation. LEVEL OF EVIDENCE Level III, retrospective study.
Collapse
Affiliation(s)
| | - Eric Locke
- Department of Orthopaedics, Civic Hospital, Ottawa, Canada
| | | | | | | | - Angela Seidel
- Department of Orthopaedics, Civic Hospital, Ottawa, Canada
| | - Zaid Jibri
- Department of Orthopaedics, Civic Hospital, Ottawa, Canada
| | | | | |
Collapse
|
16
|
Yoon YK, Park KH, Shim DW, Han SH, Lee JW, Jung M. Robotic-assisted foot and ankle surgery: a review of the present status and the future. Biomed Eng Lett 2023; 13:571-577. [PMID: 37872981 PMCID: PMC10590355 DOI: 10.1007/s13534-023-00328-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 09/17/2023] [Accepted: 09/26/2023] [Indexed: 10/25/2023] Open
Abstract
The surgical application of robotics has increased significantly since its first application in 1985 for a brain biopsy acquisition. Robotic-assisted surgery has been one of the viable options in various surgical areas, and also in orthopaedic surgery. Robotic-assisted orthopaedic surgery has gained popularity as a mean of improving accuracy, reducing complications and achieving better patient satisfaction. Numerous clinical research studies have demonstrated advantages of robotic-assisted orthopaedic surgery, however, most of that researches were about the total knee arthroplasty, total hip arthroplasty and spine surgery. The application of robotic technology in foot and ankle surgery is in a very nascent stage. Furthermore, there has been little research on intraoperative use of robotics in foot and ankle surgery in literature. A review of previous preclinical studies in foot and ankle robotics and clinical research studies in various fields of robot-assisted orthopaedic surgery shows that its potential application and benefits over conventional techniques, such as total ankle arthroplasty, minimally invasive surgery for foot and ankle trauma or other corrective procedure, and intraoperative biomechanical testing. More studies on practical application of robotic technology to surgical procedure in the field of foot and ankle surgery are needed to confirm its clinical usefulness and cost effectiveness.
Collapse
Affiliation(s)
- Yeo Kwon Yoon
- Department of Orthopaedic Surgery, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, South Korea
| | - Kwang Hwan Park
- Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Dong Woo Shim
- Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Seung Hwan Han
- Department of Orthopaedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Jin Woo Lee
- Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Min Jung
- Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
17
|
de Carvalho KAM, Barbachan Mansur NS, de Cesar Netto C. Cone-Beam Weight-Bearing Computed Tomography of Ankle Arthritis and Total Ankle Arthroplasty. Foot Ankle Clin 2023; 28:509-528. [PMID: 37536816 DOI: 10.1016/j.fcl.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Weight-bearing computed tomography has multiple advantages in evaluating the hindfoot and ankle. It can assess hindfoot and ankle alignment, pathology in ankle arthritis, and complications related to total ankle replacements. It is an essential tool in ankle osteoarthritis diagnostic, preoperative planning, and total ankle replacement outcomes. It allows for better accuracy and reproducibility of alignment and implant size. In addition, it has the potential to more assertively detect complications related to weight bearing.
Collapse
Affiliation(s)
| | | | - Cesar de Cesar Netto
- Department of Orthopedics and Rehabilitation, University of Iowa, Carver College of Medicine, Iowa City, IA, USA; Department of Orthopedic Surgery, Division of Orthopedic Foot and Ankle Surgery, Duke University, Durham, NC, USA.
| |
Collapse
|
18
|
Biela G, Piraino J, Roukis TS. An Analysis of 50 Consecutive Total Ankle Replacements Undergoing Preoperative Computerized Tomography Scan-Based, Engineer-Provided Planning From a Single Noninventor, Nonconsultant Surgeon. J Foot Ankle Surg 2023; 62:228-236. [PMID: 35871115 DOI: 10.1053/j.jfas.2022.06.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 06/14/2022] [Accepted: 06/23/2022] [Indexed: 02/03/2023]
Abstract
Preoperative computerized tomography (CT) scan-based, engineer-provided alignment plans and patient-specific pinning blocks for total ankle replacement (TAR) are available for use in the United States. However, nonbiased studies that justify the additional expense associated with this technology through support of the marketed benefits of less procedural complexity, less intraoperative radiation and reduced surgical time, are lacking. Therefore, to verify the manufacturer's proposed benefits, we sought to investigate our experience with this preoperative CT scan-based, engineer-provided plan and patient-specific pinning blocks during primary TAR. In review of our 50 TAR patients, we found that "perfect" radiographic alignment was not consistently achieved and the accuracy of component prediction was modest. Furthermore, the preoperative plans and patient-specific pinning blocks did not simplify the complexity of our operations since the operative time, intraoperative image intensification time and radiation dose per case all exceeded published historical TAR controls. Interestingly, we identified a significant difference in placement accuracy between the arced and flat-top talar component types that were implanted with the arced being more frequently malaligned. We did not find associations between preoperative deformity severity and accuracy of postoperative alignment. These findings suggest that it is imperative to have surgeons continue to rely on their own surgical planning and experience to achieve optimum radiographic alignment rather than depending on engineer-based recommendations or "surface matched" pinning blocks. Ultimately, we were unable to support the purported benefits of this CT scan-based, engineer-provided alignment plan and patient-specific pinning blocks for this manufacturer's primary TAR systems.
Collapse
Affiliation(s)
- Garrett Biela
- Post-Graduate Year 2 Resident, Department of Orthopaedic Surgery & Rehabilitation, Foot & Ankle Service Line, University of Florida College of Medicine-Jacksonville, Jacksonville, FL.
| | - Jason Piraino
- Associate Professor, Department of Orthopaedic Surgery & Rehabilitation, Chairman, Foot & Ankle Service Line, University of Florida College of Medicine-Jacksonville, Jacksonville, FL
| | - Thomas S Roukis
- Professor, Department of Orthopaedic Surgery & Rehabilitation, Foot & Ankle Service Line, University of Florida College of Medicine-Jacksonville, Jacksonville, FL
| |
Collapse
|
19
|
Benignus C, Buschner P, Meier MK, Wilken F, Rieger J, Beckmann J. Patient Specific Instruments and Patient Individual Implants—A Narrative Review. J Pers Med 2023; 13:jpm13030426. [PMID: 36983609 PMCID: PMC10051718 DOI: 10.3390/jpm13030426] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/20/2023] [Accepted: 02/25/2023] [Indexed: 03/02/2023] Open
Abstract
Joint arthroplasties are one of the most frequently performed standard operations worldwide. Patient individual instruments and patient individual implants represent an innovation that must prove its usefulness in further studies. However, promising results are emerging. Those implants seem to be a benefit especially in revision situations. Most experience is available in the field of knee and hip arthroplasty. Patient-specific instruments for the shoulder and upper ankle are much less common. Patient individual implants combine individual cutting blocks and implants, while patient individual instruments solely use individual cutting blocks in combination with off-the-shelf implants. This review summarizes the current data regarding the implantation of individual implants and the use of individual instruments.
Collapse
Affiliation(s)
- Christian Benignus
- Department of Traumatology and Orthopedic Surgery, Hospital Ludwigsburg, Posilipostr. 4, 71640 Ludwigsburg, Germany
| | - Peter Buschner
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Malin Kristin Meier
- Department of Orthopedic Surgery and Traumatology, Inselspital, University Hospital Bern, University of Bern, Freiburgstr. 4, 3010 Bern, Switzerland
| | - Frauke Wilken
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Rieger
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
| | - Johannes Beckmann
- Department of Orthopedic Surgery and Traumatology, Hospital Barmherzige Brüder Munich, Romanstr. 93, 80639 Munich, Germany
- Correspondence:
| |
Collapse
|
20
|
Stauffer TP, Kim BI, Grant C, Adams SB, Anastasio AT. Robotic Technology in Foot and Ankle Surgery: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:686. [PMID: 36679483 PMCID: PMC9864483 DOI: 10.3390/s23020686] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/11/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Recent developments in robotic technologies in the field of orthopaedic surgery have largely been focused on higher volume arthroplasty procedures, with a paucity of attention paid to robotic potential for foot and ankle surgery. The aim of this paper is to summarize past and present developments foot and ankle robotics and describe outcomes associated with these interventions, with specific emphasis on the following topics: translational and preclinical utilization of robotics, deep learning and artificial intelligence modeling in foot and ankle, current applications for robotics in foot and ankle surgery, and therapeutic and orthotic-related utilizations of robotics related to the foot and ankle. Herein, we describe numerous recent robotic advancements across foot and ankle surgery, geared towards optimizing intra-operative performance, improving detection of foot and ankle pathology, understanding ankle kinematics, and rehabilitating post-surgically. Future research should work to incorporate robotics specifically into surgical procedures as other specialties within orthopaedics have done, and to further individualize machinery to patients, with the ultimate goal to improve perioperative and post-operative outcomes.
Collapse
Affiliation(s)
| | - Billy I. Kim
- School of Medicine, Duke University, Durham, NC 27710, USA
| | - Caitlin Grant
- School of Medicine, Duke University, Durham, NC 27710, USA
| | - Samuel B. Adams
- Departmen of Orthopaedic Surgery, Duke University, Durham, NC 27710, USA
| | | |
Collapse
|
21
|
Togher CJ, Golding SL, Ferrise TD, Butterfield J, Reeves CL, Shane AM. Effects of Patient-Specific Instrumentation and Ancillary Surgery Performed in Conjunction With Total Ankle Implant Arthroplasty: Postoperative Radiographic Findings. J Foot Ankle Surg 2022; 61:739-747. [PMID: 34961682 DOI: 10.1053/j.jfas.2021.11.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 11/10/2021] [Accepted: 11/17/2021] [Indexed: 02/03/2023]
Abstract
Accuracy and reproducibility when performing total ankle implant arthroplasty (TAA) are essential for longevity of the implant, maintaining relative stability of the joint, and theoretically reducing the formation of adjacent joint arthritis in the subtalar and knee joints. Studies have helped to illustrate the accuracy of implantation when using patient-specific instrumentation in both knee and ankle implant arthroplasty. Despite the findings of these studies, few have gone on to evaluate the effects of ancillary procedures on TAA; particularly their effects on postoperative implant congruity when performed simultaneously with joint replacement surgery. In this study, preoperative plans on implant alignment based on patient-specific computed tomography images were compared with the alignment observed on immediate postoperative radiographs. Additionally, postoperative joint congruity was measured, and operative reports were assessed to determine if concomitant procedures performed with total ankle replacement had a significant effect on overall alignment. In our population, 46/47 implants were within 1.5° of their anticipated placement in the coronal plane, and 100% were within 2° of anticipated placement in the sagittal plane. Using a spearman's rank-order correlation, our data failed to show any significant relationship between conducting additional procedures in conjunction with TAA (rho = 0.178; p value = .232) and postoperative congruency of the implant. These findings help support the accuracy of ankle implantation using patient-specific instrumentation, while also supporting the appropriate use of indicated procedures in conjunction with total ankle replacement to help obtain a congruent joint postoperatively.
Collapse
Affiliation(s)
- Cody J Togher
- Fellow, Orthopedic Foot & Ankle Center, Worthington, OH.
| | - Stephanie L Golding
- Resident, Advent Health East Orlando Podiatric Surgical Residency, Orlando, FL
| | - Thomas D Ferrise
- Resident, Advent Health East Orlando Podiatric Surgical Residency, Orlando, FL
| | | | - Christopher L Reeves
- Department of Podiatric Surgery, AdventHealth System, Faculty, Advent Health East Orlando Podiatric Surgical Residency, Orlando, FL
| | - Amber M Shane
- Chair of Department of Podiatric Surgery, AdventHealth System, Faculty, Advent Health East Orlando Podiatric Surgical Residency, Orlando, FL
| |
Collapse
|
22
|
Heisler L, Vach W, Katz G, Egelhof T, Knupp M. Patient-Specific Instrumentation vs Standard Referencing in Total Ankle Arthroplasty: A Comparison of the Radiologic Outcome. Foot Ankle Int 2022; 43:741-749. [PMID: 35209725 PMCID: PMC9168897 DOI: 10.1177/10711007221077100] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Existing literature on the superiority of patient-specific instrumentation (PSI) in total ankle arthroplasty (TAA) over standard referencing (SR) is limited. Advantages presented include better implant alignment, shorter operating times, and increased accuracy of implant size prediction. The aim of this retrospective study was to analyze PSI in the hands of an experienced foot and ankle surgeon new to both PSI and SR for this specific implant, in regard to determining implant alignment, operative times, and radiologic short-term outcome and predicting implant size for tibial and talar components. METHODS Twenty-four patients undergoing TAA using PSI were compared to 25 patients using SR instrumentation. Outcome measures included alignment of the tibial component (α coronal plane, γ sagittal plane), the tibiotalar tilt (β), and the talar offset x on the sagittal view as well as the presence of radiolucent lines, operation time, and wound healing. Postoperative outcome was assessed at 6 weeks, 4 months, and 1 year postoperatively. RESULTS Implant positioning was similar in both groups, and no advantage in regard to the operative time could be seen when comparing TAA using PSI to SR. Implant size prediction was more reliable for the tibia than for the talus. Three patients (1 from the SR group and 2 from the PSI group) showed radiolucent lines around the tibial component. Two patients (both SR group) suffered delayed wound healing, albeit not requiring any additional measures. CONCLUSION The PSI method did not show an advantage over SR in regard to positioning of the components or the duration of the surgery. The current study suggests that no initial advantage of PSI over SR are to be expected in standard total ankle replacement. LEVEL OF EVIDENCE Level III, retrospective study.
Collapse
Affiliation(s)
| | - Werner Vach
- Basel Academy for Quality and Research
in Medicine, Basel, Switzerland
| | - Georg Katz
- Merian Iselin Klinik, Institute for
Radiology, Basel, Switzerland
| | - Thomas Egelhof
- Merian Iselin Klinik, Institute for
Radiology, Basel, Switzerland
| | - Markus Knupp
- University of Basel, Basel,
Switzerland,Orthopedic Surgery & Traumatology,
Mein Fusszentrum AG, Basel, Switzerland,Markus Knupp, MD, Specialist in Orthopedic
Surgery & Traumatology, Mein Fusszentrum AG, Eichenstrasse 31, Basel CH
4054, Switzerland.
| |
Collapse
|
23
|
Advances in the Application of Three-dimensional Printing for the Clinical Treatment of Osteoarticular Defects. Curr Med Sci 2022; 42:467-473. [PMID: 35451806 DOI: 10.1007/s11596-022-2565-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 10/26/2021] [Indexed: 11/03/2022]
Abstract
As a promising manufacturing technology, three-dimensional (3D) printing technology is widely used in the medical field. In the treatment of osteoarticular defects, the emergence of 3D printing technology provides a new option for the reconstruction of functional articular surfaces. At present, 3D printing technology has been used in clinical applications such as models, patient-specific instruments (PSIs), and customized implants to treat joint defects caused by trauma, sports injury, and tumors. This review summarizes the application status of 3D printing technology in the treatment of osteoarticular defects and discusses its advantages, disadvantages, and possible future research strategies.
Collapse
|
24
|
Mazzotti A, Arceri A, Zielli S, Bonelli S, Viglione V, Faldini C. Patient-specific instrumentation in total ankle arthroplasty. World J Orthop 2022; 13:230-237. [PMID: 35317257 PMCID: PMC8935326 DOI: 10.5312/wjo.v13.i3.230] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 08/09/2021] [Accepted: 02/10/2022] [Indexed: 02/06/2023] Open
Abstract
The recent increase in the adoption of total ankle arthroplasty (TAA) reflects the improvements in implant designs and surgical techniques, including the use of preoperative navigation system and patient-specific instrumentation (PSI), such as custom-made cutting guides. Cutting guides are customized with respect to each patient's anatomy based on preoperative ankle computed tomography scans, and they drive the saw intra-operatively to improve the accuracy of bone resection and implant positioning. Despite some promising results, the main queries in the literature are whether PSI improves the reliability of achieving neutral ankle alignment and more accurate implant sizing, whether it is actually superior over standard techniques, and whether it is cost effective. Moreover, the advantages of PSI in clinical outcomes are still theoretical because the current literature does not allow to confirm its superiority. The purpose of this review article is therefore to assess the current literature on PSI in TAA with regard to current implants with PSI, templating and preoperative planning strategies, alignment and sizing, clinical outcomes, cost analysis, and comparison with standard techniques.
Collapse
Affiliation(s)
- Antonio Mazzotti
- The First Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico RIzzoli, Bologna 40136, Italy
- Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum University of Bologna, Bologna 40136, Italy
| | - Alberto Arceri
- The First Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico RIzzoli, Bologna 40136, Italy
| | - Simone Zielli
- The First Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico RIzzoli, Bologna 40136, Italy
| | - Simone Bonelli
- The First Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico RIzzoli, Bologna 40136, Italy
| | - Valentina Viglione
- The First Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico RIzzoli, Bologna 40136, Italy
| | - Cesare Faldini
- The First Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico RIzzoli, Bologna 40136, Italy
- Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum University of Bologna, Bologna 40136, Italy
| |
Collapse
|
25
|
Doyle MD, Ishibashi MA, Sherick RM, Mitchell LH, Castellucci-Garza FM, Rao NM. Outcomes and Complications of the INFINITY Total Ankle: A Systematic Review. Foot Ankle Spec 2022:19386400221079491. [PMID: 35189714 DOI: 10.1177/19386400221079491] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Matthew D Doyle
- Silicon Valley Reconstructive Foot and Ankle Fellowship, Palo Alto Medical Foundation, Mountain View, California
| | - Megan A Ishibashi
- Kaiser San Francisco Bay Area Foot and Ankle Residency Program, Kaiser Foundation Hospitals, Oakland, California
| | - Ryan M Sherick
- Silicon Valley Reconstructive Foot and Ankle Fellowship, Palo Alto Medical Foundation, Mountain View, California
| | - Logan H Mitchell
- Kaiser San Francisco Bay Area Foot and Ankle Residency Program, Kaiser Foundation Hospitals, Oakland, California
| | - Francesca M Castellucci-Garza
- Kaiser San Francisco Bay Area Foot and Ankle Residency Program, Department of Orthopedics, Kaiser Foundation Hospitals, Antioch, California
| | - Nilin M Rao
- Silicon Valley Reconstructive Foot and Ankle Fellowship, Palo Alto Medical Foundation, Mountain View, California
| |
Collapse
|
26
|
Gauci MO. Patient-specific guides in orthopedic surgery. Orthop Traumatol Surg Res 2022; 108:103154. [PMID: 34838754 DOI: 10.1016/j.otsr.2021.103154] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 03/10/2021] [Accepted: 04/29/2021] [Indexed: 02/03/2023]
Abstract
The interest of patient-specific guides (PSGs) lies in reliable intraoperative achievement of preoperative planning goals. They are a form of instrumentation optimizing intraoperative precision and thus improving the safety and reproducibility of surgical procedures. Clinical superiority, however, has not been demonstrated. The various steps from design to implementation leave room for error, which needs to be known and controlled by the surgeon who is responsible for final outcome. Instituting large-scale patient-specific surgery requires management systems for guides and innovative implants which cannot be a simple extension of current practices. We shall approach the present state of knowledge regarding PSGs via 5 questions: (1) What is a PSG? Single-use instrumentation produced after preoperative planning, aiming exclusively to optimize procedural exactness. (2) How to use and assess PSGs in orthopedic surgery? Strict rules of use must be adhered to. Any deviation from the predefined objective is, necessarily, an error that must be identified as such. (3) Do PSGs provide greater surgical exactness? The contribution of PSGs varies greatly between procedures. Exactness is enhanced in the spine, in osteotomies around the knee and in bone-tumor surgery. In the shoulder, their contribution is seen only in complex cases. Data are sparse for hip replacement, and controversial for knee replacement. (4) What are the expected benefits of PSGs? As well as improving exactness, PSGs allow a lower radiation dose and shorter operating time. They also enable junior surgeons to train in techniques otherwise reserved to hyperspecialists. (5) How to include PSGs in everyday practice? As well as their potential clinical interest, PSGs involve deep changes in organization, equipment provision and economic model. LEVEL OF EVIDENCE: V; expert opinion.
Collapse
Affiliation(s)
- Marc-Olivier Gauci
- Institut Universitaire Locomoteur et du Sport (IULS), CHU de Nice, Unité de Recherche Clinique Côte d'Azur (UCA), Hôpital Pasteur II, 30, voie Romaine, 06000 Nice, France.
| |
Collapse
|
27
|
Umbel BD, Hockman T, Myers D, Sharpe BD, Berlet GC. Accuracy of CT-Derived Patient-Specific Instrumentation for Total Ankle Arthroplasty: The Impact of the Severity of Preoperative Varus Ankle Deformity. Foot Ankle Spec 2022:19386400211068262. [PMID: 34991375 DOI: 10.1177/19386400211068262] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Significant preoperative varus tibiotalar deformity was once believed to be a contraindication for total ankle arthroplasty (TAA). Our primary goal was to evaluate the influence of increasing preoperative varus tibiotalar deformity on the accuracy of final implant positioning using computed tomography (CT)-derived patient-specific guides for TAA. METHODS Thirty-two patients with varus ankle arthritis underwent TAA using CT-derived patient-specific guides. Patients were subcategorized into varying degrees of deformity based on preoperative tibiotalar angles (0°-5° neutral, 6°-10° mild, 11°-15° moderate, and >15° severe). Postoperative weightbearing radiographs were used to measure coronal plane alignment of the tibial implant relative to the target axis determined by the preoperative CT template. Average follow-up at the time of data collection was 36.8 months. RESULTS Average preoperative varus deformity was 6.06° (range: 0.66°-16.3°). Postoperatively, 96.9% (30/31) of patients demonstrated neutral implant alignment. Average postoperative tibial implant deviation was 1.54° (range: 0.17°-5.7°). Average coronal deviation relative to the target axis was 1.61° for the neutral group, 1.78° for the mild group, 0.94° for the moderate group, and 1.41° for the severe group (P = .256). Preoperative plans predicted 100% of tibial and talar implant sizes correctly within 1 size of actual implant size. Conclusion. Our study supports the claim that neutral postoperative TAA alignment can be obtained using CT-derived patient-specific instrumentation (PSI). Furthermore, final implant alignment accuracy with PSI does not appear to be impacted by worsening preoperative varus deformity. All but one patient (96.9%) achieved neutral postoperative alignment relative to the predicted target axis. LEVEL OF EVIDENCE Level IV, Clinical Case Series.
Collapse
Affiliation(s)
| | | | - Devon Myers
- Orthopedic Surgery Resident, OhioHealth, Columbus, Ohio
| | - B Dale Sharpe
- Orthopedic Surgery Resident, OhioHealth, Columbus, Ohio
| | | |
Collapse
|
28
|
Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review. INTERNATIONAL ORTHOPAEDICS 2021; 45:2445-2452. [PMID: 34345975 DOI: 10.1007/s00264-021-05145-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Accepted: 07/07/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Patient-specific instrument (PSI) may theoretically make total ankle arthroplasty (TAA) more accurate. Several studies have reported the outcomes of PSI TAA. The aim of this study is to systematically review the literature of PSI TAA. METHODS PubMed, Embase, Web of Science, and Cochrane Library databases were systematically reviewed according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines for PSI TAA. The quality of the included studies was evaluated according to Methodological Index for Non-Randomized Studies (MINORS). RESULT Nine articles were ultimately included in the systematic review. The implant position and function outcome of TAA was similar between PSI and SI. Prediction accuracy of implant size remained great difference. PSI can shorten the operative time and fluoroscopy time. The quality of current studies on PSI TAA is insufficient to produce high-level evidence. CONCLUSION PSI can get similar implant position and clinical outcome in TAA compared to SI, but current evidence is not strong enough to evaluate PSI TAA.
Collapse
|
29
|
Claassen L, Luedtke P, Nebel D, Yao D, Ettinger S, Daniilidis K, Stukenborg-Colsman C, Plaass C. Establishing a New Patient-Specific Implantation Technique for Total Ankle Replacement: An In Vitro Study. Foot Ankle Spec 2021:19386400211029741. [PMID: 34253082 DOI: 10.1177/19386400211029741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Revision rates after total ankle replacements (TARs) are higher compared with other total joint replacements. The present study aimed to establish a new patient-specific implantation (PSI) technique for TAR. MATERIAL AND METHODS A total of 10 complete Caucasian cadaver legs had whole leg computed tomography scans. The individual geometrical ankle joint axis was determined, and based on this axis, the position of the prosthesis was planned. We assessed prosthesis placement, guiding block position, and preoperative and postoperative ankle rotational axes. RESULTS The guiding block position interobserver reliability was 0.37 mm 0.45 (mean ± SD) for the tibial guiding block. The value for the first talar guiding block was 1.72 ± 1.3 mm and for the second talar guiding block, 0.61 ± 0.39 mm. The tibial slope as well as the frontal angles of the anatomical tibial axis compared to the tibial and talar articular surfaces showed no statistically relevant differences with numbers available. The deviation of the assessed preoperative joint axis to the postoperative joint axis was 14.6° ± 7.8. CONCLUSION The present study describes the results of an establishing process of a new PSI technique for TAR. The reliability of guiding block positioning and, thereby, prosthesis placement is sufficient. LEVEL OF EVIDENCE Biomechanical study.
Collapse
Affiliation(s)
- Leif Claassen
- DIAKOVERE Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover (MHH)-Hannover Medical School
| | - Philipp Luedtke
- DIAKOVERE Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover (MHH)-Hannover Medical School
| | - Dennis Nebel
- Laboratory for Biomechanics and Biomaterials of the Hannover Medical School
| | - Daiwei Yao
- DIAKOVERE Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover (MHH)-Hannover Medical School
| | - Sarah Ettinger
- DIAKOVERE Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover (MHH)-Hannover Medical School
| | | | | | - Christian Plaass
- DIAKOVERE Annastift, Orthopädische Klinik der Medizinischen Hochschule Hannover (MHH)-Hannover Medical School
| |
Collapse
|
30
|
Escudero MI, Le V, Bemenderfer TB, Barahona M, Anderson RB, Davis H, Wing KJ, Penner MJ. Total Ankle Arthroplasty Radiographic Alignment Comparison Between Patient-Specific Instrumentation and Standard Instrumentation. Foot Ankle Int 2021; 42:851-858. [PMID: 33749342 DOI: 10.1177/1071100721996379] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Several benefits are published supporting patient-specific instrumentation (PSI) in total ankle arthroplasty (TAA). This study seeks to determine if TAA with PSI yields different radiographic outcomes vs standard instrumentation (SI). METHODS Sixty-seven primary TAA patients having surgery using PSI or SI between 2013 and 2015 were retrospectively reviewed using weightbearing radiographs at 6-12 weeks postsurgery. Radiographic parameters analyzed were the medial distal tibia angle (MDTA), talar-tilt angle (TTA), anatomic sagittal distal tibia angle (aSDTA), lateral talar station (LTS), and talar component inclination angle (TCI). A comparison of the 2 groups for each radiologic parameter's distribution was performed using a nonparametric median test and Fisher exact test. Furthermore, TAAs with all radiographic measurements within acceptable limits were classified as "perfectly aligned." The rate of "perfectly aligned" TAAs between groups was compared using a Fisher exact test with a significance of .05. RESULTS Of the 67 TAAs, 51 were done with PSI and 16 with SI. There were no differences between groups in MDTA (P = .174), TTA (P = .145), aSDTA (P = .98), LTS (P = .922), or TCI angle (P = .98). When the rate of "perfectly aligned TAA" between the 2 groups were compared, there was no significant difference (P = .35). CONCLUSION No significant radiographic alignment differences were found between PSI and SI implants. This study showed that both techniques achieve reproducible TAA radiographic coronal and sagittal alignment for the tibial component when performed by experienced surgeons. The talar component's sagittal alignment is similar whether or not PSI was used but is noticeably different from normal anatomic alignment by design. LEVEL OF EVIDENCE Level III, retrospective cohort study using prospectively collected data.
Collapse
Affiliation(s)
- Mario I Escudero
- Department of Orthopaedics, University of Chile, Santiago, Chile
| | - Vu Le
- Pacific Orthopaedic Associates, Alhambra, CA, USA
| | | | | | | | - Hodges Davis
- Department of Orthopaedics, OrthoCarolina, Charlotte, NC, USA
| | - Kevin J Wing
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Murray J Penner
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
31
|
Townshend DN, Bing AJF, Clough TM, Sharpe IT, Goldberg A, On behalf of the UK INFINITY study group. Early experience and patient-reported outcomes of 503 INFINITY total ankle arthroplasties. Bone Joint J 2021; 103-B:1270-1276. [PMID: 34192928 PMCID: PMC9948432 DOI: 10.1302/0301-620x.103b7.bjj-2020-2058.r2] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
AIMS This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes. METHODS Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence. RESULTS In all, 500 patients reached six-month follow-up, 420 reached one-year follow-up, and 188 reached two-year follow-up. The mean age was 67.8 years (23.9 to 88.5). A total of 38 patients (7.5%) presented with inflammatory arthritis. A total of 101 (20.0%) of implantations used patient-specific instrumentation; 167 patients (33.1%) underwent an additional procedure at the time of surgery. A total of seven patients died of unrelated causes, two withdrew, and one was lost to follow-up. The mean follow-up was 16.2 months (6 to 36). There was a significant improvement from baseline across all functional outcome scores at six months, one, and two years. There was no significant difference in outcomes with the use of patient-specific instrumentation, type of arthritis, or COFAS type. Five (1.0%) implants were revised. The overall complication rate was 8.8%. The non-revision reoperation rate was 1.4%. The 30-day readmission rate was 1.2% and the one-year mortality 0.74%. CONCLUSION The early experience and complications reported in this study support the current use of the INFINITY TAA as a safe and effective implant in the treatment of end-stage ankle arthritis. Cite this article: Bone Joint J 2021;103-B(7):1270-1276.
Collapse
Affiliation(s)
- David N. Townshend
- Northumbria HealthCare NHS Trust, North Shields, Tyne and Wear, UK,Correspondence should be sent to David N. Townshend. E-mail:
| | - Andrew J. F. Bing
- Robert Jones and Agnes Hunt Orthopaedic and District Hospital NHS Trust, Oswestry, Shropshire, UK
| | | | - Ian T. Sharpe
- Royal Devon and Exeter NHS Foundation Trust, Exeter, Devon, UK
| | - Andy Goldberg
- The Wellington Hospital, London, UK,UCL Division of Surgery, London, UK,Imperial College, London, UK
| | | |
Collapse
|
32
|
A new ligament-compatible patient-specific 3D-printed implant and instrumentation for total ankle arthroplasty: from biomechanical studies to clinical cases. J Orthop Traumatol 2020; 21:16. [PMID: 32876778 PMCID: PMC7468019 DOI: 10.1186/s10195-020-00555-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/29/2020] [Indexed: 12/18/2022] Open
Abstract
Background Computer navigation and patient-specific instrumentation for total ankle arthroplasty have still to demonstrate their theoretical ability to improve implant positioning and functional outcomes. The purpose of this paper is to present a new and complete total ankle arthroplasty customization process for severe posttraumatic ankle joint arthritis, consisting of patient-specific 3D-printed implant and instrumentation, starting from a ligament-compatible design. Case presentation The new customization process was proposed in a 57-year-old male patient and involved image analysis, joint modeling, prosthesis design, patient-specific implant and instrumentation development, relevant prototyping, manufacturing, and implantation. Images obtained from a CT scan were processed for a 3D model of the ankle, and the BOX ankle prosthesis (MatOrtho, UK) geometries were customized to best fit the model. Virtual in silico, i.e., at the computer, implantation was performed to optimize positioning of these components. Corresponding patient-specific cutting guides for bone preparation were designed. The obtained models were printed in ABS by additive manufacturing for a final check. Once the planning procedure was approved, the models were sent to final state-of-the-art additive manufacturing (the metal components using cobalt-chromium-molybdenum powders, and the guides using polyamide). The custom-made prosthesis was then implanted using the cutting guides. The design, manufacturing, and implantation procedures were completed successfully and consistently, and final dimensions and location for the implant corresponded with the preoperative plan. Immediate post-op X-rays showed good implant positioning and alignment. After 4 months, clinical scores and functional abilities were excellent. Gait analysis showed satisfactory joint moment at the ankle complex and muscle activation timing within normality. Conclusions The complete customization process for total ankle arthroplasty provided accurate and reliable implant positioning, with satisfactory short-term clinical outcomes. However, further studies are needed to confirm the potential benefits of this complete customization process. Level of evidence 5. Case report.
Collapse
|
33
|
Sung KS. Total ankle arthroplasty. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2020. [DOI: 10.5124/jkma.2020.63.8.445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
For end-stage ankle arthritis, either arthrodesis or total ankle arthroplasty is a available surgical option. With the failure of earlier generation of arthroplasty, arthrodesis has been the gold standard. However, there are some considerable weaknesses of the arthrodesis. Current total ankle arthroplasty is presently an effective surgical treatment for endstage ankle arthritis with much improvement. The goals of surgery are to decrease pain, preserve range of motion, and eventually improve the patient’s quality of life. Recent literatures on total ankle arthroplasty havs shown successful long-term clinical results due to the innovation of second-generation implants, including more anatomic concepts and designs. For successful outcomes, a thorough evaluation of the entire lower limb alignment, deformities of the foot and ankle, and proper selection of patients are very important. Nevertheless, complications, such as wound problems, osteolysis, gutter pain or impingement, infection, loosening, and others, may occur. In this review, we provide a summary of the current research on total ankle arthroplasty.
Collapse
|
34
|
Daniels TR, Wilson IR, Fu JM. What's New in Foot and Ankle Surgery. J Bone Joint Surg Am 2020; 102:856-865. [PMID: 32187125 DOI: 10.2106/jbjs.20.00068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Timothy R Daniels
- Division of Orthopaedic Surgery, St. Michael's Hospital and University of Toronto, Toronto, Ontario, Canada
| | | | | |
Collapse
|
35
|
Escudero MI, Symes M, Bemenderfer TB, Barahona M, Anderson R, Davis H, Wing KJ, Penner MJ. Does Patient-Specific Instrumentation Have a Higher Rate of Early Osteolysis Than Standard Referencing Techniques in Total Ankle Arthroplasty? A Radiographic Analysis. Foot Ankle Spec 2020; 13:32-42. [PMID: 30757922 DOI: 10.1177/1938640019828069] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Introduction: Patient-specific instrumentation (PSI) has been developed for total ankle arthroplasty (TAA), with proven benefits. One concern regarding PSI is the need for more soft tissue dissection in order to accurately position the PSI guides, which has the theoretical disadvantage of increased osteolysis. The purpose of our study is to compare the incidence and magnitude of osteolysis for the INFINITY Total Ankle System between PSI and standard referencing (SR) techniques. Methods: Sixty-seven patients who underwent primary TAA using Prophecy (PSI) or SR technique between 2013 and 2015 were reviewed in a retrospective observational study. Osteolysis was assessed on radiographs at 2 years. The incidence was calculated by binomial distribution. The number of zones compromised and the magnitude of osteolysis was calculated using the median as a summary statistic and interquartile range as dispersion statistic. Fisher exact test was used to compare both groups, then a regression model was estimated to calculate the odds ratio for osteolysis. Results: Of the 67 TAAs, 51 were in the PSI group and 16 in the SR group. In the PSI group the incidence, number of compromised zones (CZ), and magnitude was 41% (25%-59%), 1 [1-2], and 2 [2-3], respectively. In the SR group these were 36% (13%-65%), 3 [2-3], and 3 [2-4], respectively. No significant differences were found (P = .46, P = .12, P = .33). A slightly higher risk of osteolysis was found in the PSI group (odds ratio = 1.33 [0.36-4.83]) (P = .46). The majority of lesions were in 1 zone with size of 2 to 5 mm (63% for all cohort, 64% PSI, 60% SR). Two cases underwent revision for aseptic loosening, 1 in the SR group and 1 in the PSI group. Conclusion: According to our data, there is no significant difference between PSI and SR in terms of risk, incidence, size and magnitude of osteolysis in the INFINITY Total Ankle System at 2 years. Levels of Evidence: Therapeutic, Level III, Retrospective cohort study.
Collapse
Affiliation(s)
- Mario I Escudero
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Michael Symes
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Thomas Bradford Bemenderfer
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Maximiliano Barahona
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Robert Anderson
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Hodges Davis
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Kevin J Wing
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| | - Murray J Penner
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada (MIE, MS, KJW, MJP).,Orthocarolina Foot and Ankle Institute, Charlotte, North Carolina (TBB, RA, HD).,Department of Orthopaedics, University of Chile, Santiago, Chile (MIE, MB)
| |
Collapse
|
36
|
Adukia V, Mangwani J, Issac R, Hussain S, Parker L. Current concepts in the management of ankle arthritis. J Clin Orthop Trauma 2020; 11:388-398. [PMID: 32405197 PMCID: PMC7211821 DOI: 10.1016/j.jcot.2020.03.020] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Accepted: 03/30/2020] [Indexed: 01/15/2023] Open
Abstract
Ankle arthritis is a common condition. It causes a significant socioeconomic burden, and is associated with significant morbidity. Patients with ankle arthritis are either elderly with significant co-morbidities, or young adults who have previously suffered with ankle injuries, resulting in post-traumatic arthritis. There is a wide variation in the management of these patients with ankle arthritis. We therefore present an overview of the current evidence based management of patients with symptomatic ankle arthritis.
Collapse
Affiliation(s)
- V. Adukia
- Academic Team of Musculoskeletal Surgery, Leicester General Hospital, Gwendolen Road, Leicester, LE5 4PW, United Kingdom,Corresponding author.
| | - J. Mangwani
- Academic Team of Musculoskeletal Surgery, Leicester General Hospital, Gwendolen Road, Leicester, LE5 4PW, United Kingdom
| | - R. Issac
- Academic Team of Musculoskeletal Surgery, Leicester General Hospital, Gwendolen Road, Leicester, LE5 4PW, United Kingdom
| | - S. Hussain
- Barts Health NHS Trust, The Royal London Hospital, Whitechapel, London, E1 1BB, United Kingdom
| | - L. Parker
- Barts Health NHS Trust, The Royal London Hospital, Whitechapel, London, E1 1BB, United Kingdom
| |
Collapse
|
37
|
Savage-Elliott I, Wu VJ, Wu I, Heffernan JT, Rodriguez R. Comparison of Time and Cost Savings Using Different Cost Methodologies for Patient-Specific Instrumentation vs Standard Referencing in Total Ankle Arthroplasty. FOOT & ANKLE ORTHOPAEDICS 2019; 4:2473011419884278. [PMID: 35097347 PMCID: PMC8697097 DOI: 10.1177/2473011419884278] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Background: Patient-specific 3-D printing cutting blocks (PSI) have been used instead of traditional intramedullary cutting guides. We hypothesized that PSI would lead to significantly decreased operating room (OR) time and significant cost savings to our institution with noninferior radiographic outcomes and no difference in expected vs actual implant size when compared with standard referencing (SR). Methods: Patients who had undergone total ankle replacements at our institution from 2013 through 2016 were included in the study. Associations between demographic variables and postoperative alignment in the SR vs PSI group were calculated using the Wilcoxon rank-sum test and the intraclass correlation coefficient. The cost of the operation was calculated using both an institutionally based fixed cost of OR time and using Time Driven Activity Based Cost (TDABC) accounting. A total of 43 patients were included in the study, 13 in the SR group and 30 in the PSI group. Results: Operative time (168 vs 137 minutes) and tourniquet time (123 vs 113 minutes) were significantly lower in the PSI vs the SR group. PSI predictions were accurate 100% of the time for tibial components and 83% of the time for talar components. Average costs of TAA using PSI were significantly reduced by $7597.00 when using traditional OR accounting, whereas PSI was $836.00 more expensive on average using TDABC accounting. Conclusion: Further research is needed to determine the cost-effectiveness of PSI vs SR in TAA; however, it does appear to save time intraoperatively. The long-term effect on clinical outcomes requires further study. Level of Evidence: Level III, case-control study.
Collapse
Affiliation(s)
- Ian Savage-Elliott
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| | - Victor J Wu
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| | - Isabella Wu
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| | | | - Ramon Rodriguez
- Department of Orthopedic Surgery, Tulane University, New Orleans, LA, USA
| |
Collapse
|