1
|
Zhang H, Zhang S, Li Y, Li L, Hou X. Biochar/sodium alginate mixed matrix membrane as adsorbent for in-syringe solid-phase extraction towards trace nitroimidazoles in water samples prior to ultra-high-performance liquid chromatography-tandem mass spectrometry analysis. J Sep Sci 2023; 46:e2300316. [PMID: 37688330 DOI: 10.1002/jssc.202300316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 08/30/2023] [Accepted: 09/03/2023] [Indexed: 09/10/2023]
Abstract
In the present work, the herb (Poria cocos (Schw.) Wolf) residue, as an environmentally friendly and renewable biomass source, was converted into novel biochar. Biochar/sodium alginate mixed matrix membrane was fabricated. On this basis, a biochar/sodium alginate mixed matrix membrane-based in-syringe solid-phase extraction was developed combined with ultra-high performance liquid chromatography-tandem mass spectrometry to determine nitroimidazoles in water samples. The factors including times of exaction, type, and volume of elution solvent, and sample solution pH were thoroughly optimized. Then the correlation coefficient was 0.9995-0.9997. The limit of detection of four analytes was between 0.006 and 0.014 ng/mL, and the recovery was between 79.02% and 99.1%. Consequently, the established method would provide a new perspective on monitoring nitroimidazoles in water samples.
Collapse
Affiliation(s)
- Hongyu Zhang
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, P. R. China
| | - Sijia Zhang
- School of Pharmaceutical Engineering, Shenyang Pharmaceutical University, Shenyang, P. R. China
| | - Yingying Li
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, P. R. China
| | - Lin Li
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, P. R. China
| | - Xiaohong Hou
- School of Pharmaceutical Engineering, Shenyang Pharmaceutical University, Shenyang, P. R. China
| |
Collapse
|
2
|
Mohan B, Singh G, Chauhan A, Pombeiro AJL, Ren P. Metal-organic frameworks (MOFs) based luminescent and electrochemical sensors for food contaminant detection. JOURNAL OF HAZARDOUS MATERIALS 2023; 453:131324. [PMID: 37080033 DOI: 10.1016/j.jhazmat.2023.131324] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 03/10/2023] [Accepted: 03/29/2023] [Indexed: 05/03/2023]
Abstract
With the increasing population, food toxicity has become a prevalent concern due to the growing contaminants of food products. Therefore, the need for new materials for toxicant detection and food quality monitoring will always be in demand. Metal-organic frameworks (MOFs) based on luminescence and electrochemical sensors with tunable porosity and active surface area are promising materials for food contaminants monitoring. This review summarizes and studies the most recent progress on MOF sensors for detecting food contaminants such as pesticides, antibiotics, toxins, biomolecules, and ionic species. First, with the introduction of MOFs, food contaminants and materials for toxicants detection are discussed. Then the insights into the MOFs as emerging materials for sensing applications with luminescent and electrochemical properties, signal changes, and sensing mechanisms are discussed. Next, recent advances in luminescent and electrochemical MOFs food sensors and their sensitivity, selectivity, and capacities for common food toxicants are summarized. Further, the challenges and outlooks are discussed for providing a new pathway for MOF food contaminant detection tools. Overall, a timely source of information on advanced MOF materials provides materials for next-generation food sensors.
Collapse
Affiliation(s)
- Brij Mohan
- School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China; Centro de Química Estrutural, Institute of Molecular Sciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal.
| | - Gurjaspreet Singh
- Department of Chemistry & Centre for Advanced Studies in Chemistry, Panjab University, Chandigarh 160014, India
| | - Archana Chauhan
- Department of Chemistry, Kurukshetra University, Kurukshetra, Haryana 136119, India
| | - Armando J L Pombeiro
- Centro de Química Estrutural, Institute of Molecular Sciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal.
| | - Peng Ren
- School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China.
| |
Collapse
|
3
|
Solidified floating organic drop microextraction in tandem with syringe membrane miro-solid phase extraction for sequential detection of thallium (III) and thallium (I) by graphite furnace atomic absorption spectrometry. ARAB J CHEM 2022. [DOI: 10.1016/j.arabjc.2022.104335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
4
|
Gutiérrez-Serpa A, Pasán J, Jiménez-Abizanda AI, Kaskel S, Senkovska I, Pino V. Thin-film microextraction using the metal-organic framework DUT-52 for determining endocrine disrupting chemicals in cosmetics. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
5
|
Kardani F, Mirzajani R. Electrospun polyacrylonitrile /MIL-53(Al) MOF@ SBA-15/ 4, 4ʹ-bipyridine nanofibers for headspace solid-phase microextraction of benzene homologues in environmental water samples with GC-FID detection. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
6
|
Metal-organic framework modified carbon cloth for electric field enhanced thin film microextraction of sulfonamides in animal-derived food. J Chromatogr A 2022; 1674:463120. [DOI: 10.1016/j.chroma.2022.463120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 04/16/2022] [Accepted: 05/04/2022] [Indexed: 11/18/2022]
|
7
|
Gutiérrez-Serpa A, Kundu T, Pasán J, Jiménez-Abizanda AI, Kaskel S, Senkovska I, Pino V. Zirconium-Based Metal-Organic Framework Mixed-Matrix Membranes as Analytical Devices for the Trace Analysis of Complex Cosmetic Samples in the Assessment of Their Personal Care Product Content. ACS APPLIED MATERIALS & INTERFACES 2022; 14:4510-4521. [PMID: 35006682 PMCID: PMC8796172 DOI: 10.1021/acsami.1c21284] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/29/2021] [Indexed: 06/14/2023]
Abstract
A device comprising a zirconium-based metal-organic framework (MOF) mixed-matrix membrane (MMM) framed in a plastic holder has been used to monitor the content of personal care products (PCPs) in cosmetic samples. Seven different devices containing the porous frameworks UiO-66, UiO-66-COOH, UiO-67, DUT-52, DUT-67, MOF-801, and MOF-808 in polyvinylidene fluoride (PVDF) membranes were studied. Optimized membranes reach high adsorption capacities of PCPs, up to 12.5 mg·g-1 benzophenone in a 3.0 mg·L-1 sample. The MMM adsorption kinetics, uptake measurements, and isotherm studies were carried out with aqueous standard solutions of PCPs to ensure complete characterization of the performance. The studies demonstrate the high applicability and selectivity of the composites prepared, highlighting the performance of PVDF/DUT-52 MMM that poses uptakes up to 78% for those PCPs with higher affinity while observing detection limits for the entire method down to 0.03 μg·L-1. The PVDF/DUT-52 device allowed the detection of parabens and benzophenones in the samples, with PCPs found at concentrations of 1.9-24 mg·L-1.
Collapse
Affiliation(s)
- Adrián Gutiérrez-Serpa
- Laboratorio
de Materiales para Análisis Químicos (MAT4ALL), Departamento
de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206 La Laguna, Tenerife, Spain
- Unidad
de Investigación de Bioanalítica y Medioambiente, Instituto
Universitario de Enfermedades Tropicales y Salud Pública de
Canarias, Universidad de La Laguna (ULL), 38206 La Laguna, Tenerife, Spain
| | - Tanay Kundu
- Department
of Chemistry, SRM Institute of Science and
Technology, Kattankulathur, 603203 Chennai, Tamil Nadu, India
| | - Jorge Pasán
- Laboratorio
de Materiales para Análisis Químicos (MAT4ALL), Departamento
de Química, Unidad Departamental de Química Inorgánica, Universidad de La Laguna (ULL), 38206 La Laguna, Tenerife, Spain
| | - Ana I. Jiménez-Abizanda
- Laboratorio
de Materiales para Análisis Químicos (MAT4ALL), Departamento
de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206 La Laguna, Tenerife, Spain
| | - Stefan Kaskel
- Technische
Universität Dresden (TUD), Bergstrasse 66, 01069 Dresden, Germany
| | - Irena Senkovska
- Technische
Universität Dresden (TUD), Bergstrasse 66, 01069 Dresden, Germany
| | - Verónica Pino
- Laboratorio
de Materiales para Análisis Químicos (MAT4ALL), Departamento
de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206 La Laguna, Tenerife, Spain
- Unidad
de Investigación de Bioanalítica y Medioambiente, Instituto
Universitario de Enfermedades Tropicales y Salud Pública de
Canarias, Universidad de La Laguna (ULL), 38206 La Laguna, Tenerife, Spain
| |
Collapse
|