1
|
Chiș IA, Andrei V, Muntean A, Moldovan M, Mesaroș AȘ, Dudescu MC, Ilea A. Salivary Biomarkers of Anti-Epileptic Drugs: A Narrative Review. Diagnostics (Basel) 2023; 13:diagnostics13111962. [PMID: 37296814 DOI: 10.3390/diagnostics13111962] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 05/30/2023] [Accepted: 06/02/2023] [Indexed: 06/12/2023] Open
Abstract
Saliva is a biofluid that reflects general health and that can be collected in order to evaluate and determine various pathologies and treatments. Biomarker analysis through saliva sampling is an emerging method of accurately screening and diagnosing diseases. Anti-epileptic drugs (AEDs) are prescribed generally in seizure treatment. The dose-response relationship of AEDs is influenced by numerous factors and varies from patient to patient, hence the need for the careful supervision of drug intake. The therapeutic drug monitoring (TDM) of AEDs was traditionally performed through repeated blood withdrawals. Saliva sampling in order to determine and monitor AEDs is a novel, fast, low-cost and non-invasive approach. This narrative review focuses on the characteristics of various AEDs and the possibility of determining active plasma concentrations from saliva samples. Additionally, this study aims to highlight the significant correlations between AED blood, urine and oral fluid levels and the applicability of saliva TDM for AEDs. The study also focuses on emphasizing the applicability of saliva sampling for epileptic patients.
Collapse
Affiliation(s)
- Ioana-Andreea Chiș
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Medicine and Pharmacy "Iuliu Hațieganu", 400012 Cluj-Napoca, Romania
| | - Vlad Andrei
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Medicine and Pharmacy "Iuliu Hațieganu", 400012 Cluj-Napoca, Romania
| | - Alexandrina Muntean
- Department of Paediatric Dentistry, Faculty of Dentistry, University of Medicine and Pharmacy "Iuliu Hațieganu", 400012 Cluj-Napoca, Romania
| | - Marioara Moldovan
- Department of Polymer Composites, Institute of Chemistry "Raluca Ripan", University Babes-Bolyai, 400294 Cluj-Napoca, Romania
| | - Anca Ștefania Mesaroș
- Department of Dental Propaedeutics and Aesthetics, University of Medicine and Pharmacy "Iuliu Hațieganu", 400012 Cluj-Napoca, Romania
| | - Mircea Cristian Dudescu
- Department of Mechanical Engineering, Faculty of Automotive, Mechatronics and Mechanical Engineering, Technical University of Cluj-Napoca, 400641 Cluj-Napoca, Romania
| | - Aranka Ilea
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Medicine and Pharmacy "Iuliu Hațieganu", 400012 Cluj-Napoca, Romania
| |
Collapse
|
2
|
Olędzka I, Plenis A, Kowalski P, Bączek T, Roszkowska A. Analytical aspects of sample handling during the quantification of selective serotonin reuptake inhibitors in clinical applications. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/15/2023]
|
3
|
Cheng JYK, Hui JWS, Chan WS, So MH, Hong YH, Leung WT, Ku KW, Yeung HS, Lo KM, Fung KM, Ip CY, Dao KL, Cheung BKK. Interpol review of toxicology 2019-2022. Forensic Sci Int Synerg 2022; 6:100303. [PMID: 36597440 PMCID: PMC9799715 DOI: 10.1016/j.fsisyn.2022.100303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Bobbie Kwok-keung Cheung
- Corresponding author. Government Laboratory, 7/F, Homantin Government Offices, 88 Chung Hau Street, Ho Man Tin, Kowloon, SAR, Hong Kong, China. http://www.govtlab.gov.hk/
| |
Collapse
|
4
|
Pascual-Caro S, Borrull F, Calull M, Aguilar C. Recent chromatographic and electrophoretic based methods for determining drugs of abuse in urine and oral fluid: A review from 2018 to June 2021. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116705] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
5
|
Wille SMR, Desharnais B, Pichini S, Trana AD, Busardò FP, Wissenbach DK, Peters FT. Liquid Chromatography High Resolution Mass Spectrometry in Forensic Toxicology: What Are the Specifics of Method Development, Validation and Quality Assurance for Comprehensive Screening Approaches? Curr Pharm Des 2022; 28:1230-1244. [PMID: 35619258 DOI: 10.2174/1381612828666220526152259] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 04/12/2022] [Indexed: 11/22/2022]
Abstract
The use of High Resolution Mass Spectrometry (HRMS) has increased over the past decade in clinical and forensic toxicology, especially for comprehensive screening approaches. Despite this, few guidelines of this field have specifically addressed HRMS issues concerning compound identification, validation, measurement uncertainty and quality assurance. To fully implement this technique, certainly in an era in which the quality demands for laboratories are ever increasing due to various norms (e.g. the International Organization for Standardization's ISO 17025), these specific issues need to be addressed. This manuscript reviews 26 HRMS-based methods for qualitative systematic toxicological analysis (STA) published between 2011 and 2021. Key analytical data such as samples matrices, analytical platforms, numbers of analytes and employed mass spectral reference databases/libraries as well as the studied validation parameters are summarized and discussed. The article further includes a critical review of targeted and untargeted data acquisition approaches, available HRMS reference databases and libraries as well as current guidelines for HRMS data interpretation with a particular focus on identification criteria. Moreover, it provides an overview on current recommendations for the validation and determination measurement uncertainty of qualitative methods. Finally, the article aims to put forward suggestions for method development, compound identification, validation experiments to be performed, and adequate determination of measurement uncertainty for this type of wide-range qualitative HRMS-based methods.
Collapse
Affiliation(s)
- Sarah M R Wille
- Unit Toxicology, National Institute of Criminalistics and Criminology (NICC), Brussels, Belgium
| | - Brigitte Desharnais
- Laboratoire de sciences judiciaires et de médecine légale, Department of Toxicology, 1701 Parthenais St., Montréal, Québec, H2K 3S7, Canada
| | - Simona Pichini
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy
| | - Annagiulia Di Trana
- Department of Excellence of Biomedical Sciences and Public Health, University "Politecnica delle Marche", Ancona, Italy
| | - Francesco Paolo Busardò
- Department of Excellence of Biomedical Sciences and Public Health, University "Politecnica delle Marche", Ancona, Italy
| | - Dirk K Wissenbach
- Institute of Forensic Medicine, Jena University Hospital, Jena, Germany
| | | |
Collapse
|
6
|
Roszkowska A, Plenis A, Kowalski P, Bączek T, Olędzka I. Recent advancements in techniques for analyzing modern, atypical antidepressants in complex biological matrices and their application in biomedical studies. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
7
|
Růžička M, Kaljurand M, Gorbatšova J, Vaher M, Mazina-Šinkar J. Portable fully automated oral fluid extraction device for illegal drugs. Talanta 2022; 243:123389. [DOI: 10.1016/j.talanta.2022.123389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 03/08/2022] [Accepted: 03/11/2022] [Indexed: 11/15/2022]
|
8
|
Mashal MS, Nalin M, Bevalot F, Sallet P, Guitton J, Machon C. Simultaneous quantification of nineteen Non-Steroidal Anti-Inflammatory Drugs in oral fluid by liquid chromatography - high resolution mass spectrometry. Application on ultratrail runner's oral fluid. Drug Test Anal 2022; 14:701-712. [PMID: 34989157 DOI: 10.1002/dta.3216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/13/2021] [Accepted: 12/17/2021] [Indexed: 11/08/2022]
Abstract
Non-steroidal anti-inflammatory drugs (NSAIDs) are a therapeutic class suspected to be used by ultratrail runners. The use of NSAIDs during ultratrails is known to be associated with various adverse effects. To study the prevalence of NSAIDs intake in ultratrail runners, oral fluid (OF) is a relevant matrix as it is noninvasive and easy to collect. The aim of our work was to develop and validate a liquid-liquid extraction followed by a LC-MS/HRMS method for the simultaneous quantification of nineteen NSAIDs in OF. After a comparison of different liquid-liquid extraction methods, a double step liquid-liquid extraction with chloroform was performed on OF collected with Quantisal®, with extraction recoveries higher than 90 %. An Accucore AQ column was selected for the chromatographic separation of NSAIDs. The Q Exactive Plus mass spectrometer operated in full scan and ddms2 mode after positive and negative electrospray ionization. Selectivity, carry-over, matrix effect, and linearity were validated for all NSAIDs. Within-day and between-day accuracy and precision were validated for all NSAIDs (< 15 % for QC samples and < 20 % for LLOQ), except within-day accuracy for the LLOQ of mefenamic acid. A stability study was also performed on OF at room temperature and +4 °C. The method was applied on OF from runners who participate to Ultra Trail du Mont-Blanc®.
Collapse
Affiliation(s)
- Mohammad Shafiq Mashal
- Biochemistry and Pharmaco-toxicology laboratory, Lyon Sud Hospital, University Hospital of Lyon, Pierre-Bénite, France.,Toxicology department, pharmacy faculty of Kabul University, Kabul, Afghanistan
| | - Marie Nalin
- Biochemistry and Pharmaco-toxicology laboratory, Lyon Sud Hospital, University Hospital of Lyon, Pierre-Bénite, France
| | | | | | - Jérôme Guitton
- Biochemistry and Pharmaco-toxicology laboratory, Lyon Sud Hospital, University Hospital of Lyon, Pierre-Bénite, France.,Toxicology laboratory, ISPB Pharmacy Faculty of Lyon, University of Lyon, France
| | - Christelle Machon
- Biochemistry and Pharmaco-toxicology laboratory, Lyon Sud Hospital, University Hospital of Lyon, Pierre-Bénite, France.,Analytical chemistry laboratory, ISPB Pharmacy Faculty of Lyon, University of Lyon, France
| |
Collapse
|
9
|
Andresen Bergström M, Lövgren H, Abrahamsson A, Eriksson EK, Lindbjer Andersson M, Komorowska M, Axelsson MAB. Rethinking Drug Analysis in Healthcare: High-Throughput Analysis of 71 Drugs of Abuse in Oral Fluid using Ion Mobility - High Resolution Mass Spectrometry. J Anal Toxicol 2021; 46:765-775. [PMID: 34746960 DOI: 10.1093/jat/bkab114] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 10/26/2021] [Accepted: 11/04/2021] [Indexed: 01/22/2023] Open
Abstract
We have identified a clinical need for a sensitive, specific, flexible, comprehensive, and affordable analytical technology to efficiently detect polydrug use. In addition, the current standard practise of surveilled urine sampling is uncomfortable for the patient, hence more patient-friendly sample collection methods are requested. To fill these needs, we have developed and validated a high-throughput liquid chromatography - high resolution mass spectrometry (LC-HRMS) method for analysis of DoA in oral fluid (OF). The method covers a panel of 71 substances including traditional drugs of abuse (DoA), prescription narcotics and new psychoactive substances (NPS), with a guaranteed limit of identification of <3 µg/L for 87% of the analytes. Method validation showed high accuracy (>99.7%), sensitivity (>99.7%) and specificity (100%). Most analytes had a high process efficiency during the salting out liquid-liquid extraction (SALLE) workup and no or only a minor matrix effect during the analysis. We have implemented this method in clinical routine, and present data from 18,579 OF samples collected during routine patient treatment in mainly psychiatric and addiction clinics in West Sweden between September 2020 and June 2021. 71% of the samples were positive and a total of 41,472 DoA findings were detected. Amphetamine (27%), buprenorphine (25%), nordiazepam (18%) and alprazolam (16%) were most prevalent. NPS were detected in 189 samples (1.0%). Occurrence of polydrug use was common, 34% of the positive samples contained three analytes or more and 12% six or more. To the best of our knowledge, this is the first method for comprehensive analysis of DoA in OF using HRMS and the largest dataset published on detection of DoA in OF. With the current complex and variable drug use pattern, this broad, cost-effective and reliable method has largely replaced immunoassay screening in urine in our laboratory.
Collapse
Affiliation(s)
- Moa Andresen Bergström
- Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Laboratory Medicine, Institute of Biomedicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Hanna Lövgren
- Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Anna Abrahamsson
- Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Emma K Eriksson
- Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Gothenburg, Sweden
| | | | - Marta Komorowska
- Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Magnus A B Axelsson
- Laboratory of Clinical Chemistry, Sahlgrenska University Hospital, Gothenburg, Sweden.,Department of Laboratory Medicine, Institute of Biomedicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
10
|
Vejar-Vivar C, García-Valverde MT, Mardones C, Lucena R, Cárdenas S. Polydopamine coated hypodermic needles as a microextraction device for the determination of tricyclic antidepressants in oral fluid by direct infusion MS/MS. RSC Adv 2021; 11:22683-22690. [PMID: 35480419 PMCID: PMC9034363 DOI: 10.1039/d1ra02721b] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 06/22/2021] [Indexed: 01/24/2023] Open
Abstract
In-needle microextraction consists of the confinement of the sorbent, by coating or packing, inside a metallic needle. The size of the needles reduces the eluent requirements providing an efficient preconcentration of the analytes. In this work, hypodermic needles coated with polydopamine (PDA) are presented as microextraction devices to isolate six tricyclic antidepressants from oral fluid samples. The coating consists of the in-surface polymerization of dopamine at pH 8.5 and mild conditions (room temperature and water as solvent). The PDA coating over the stainless-steel surface confers the needles with a high extraction ability towards the target analytes. After the extraction, the eluates were analyzed by direct infusion MS spectrometry, working in multiple reaction monitoring (MRM) mode, which provided a sample throughput of 30 samples per hour. The variables affecting the synthesis (number of coating cycles, the concentration of dopamine, and needle surface pre-treatment) and the extraction (sample salinity, sample loading cycles, and the number of elution strokes) were studied in depth. Under the optimum conditions, a matrix-matched calibration model was built. The limits of quantification are between 2 and 5 ng mL−1 with linear ranges up to 1000 ng mL−1 for all analytes. The precision, expressed as relative standard deviation (RSD), is better than 10% for all analytes. Accuracy was calculated as recovery, and the obtained values are between 84% and 107%. A single-blind assay was also performed to evaluate the suitability of the method for real application. Hypodermic needles coated with polydopamine for the extraction of antidepressants.![]()
Collapse
Affiliation(s)
- Carmina Vejar-Vivar
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba Campus de Rabanales, Edificio Marie Curie E-14071 Córdoba Spain .,Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción Casilla 237, Correo 3 Concepción Chile
| | - María Teresa García-Valverde
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba Campus de Rabanales, Edificio Marie Curie E-14071 Córdoba Spain
| | - Claudia Mardones
- Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción Casilla 237, Correo 3 Concepción Chile
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba Campus de Rabanales, Edificio Marie Curie E-14071 Córdoba Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba Campus de Rabanales, Edificio Marie Curie E-14071 Córdoba Spain
| |
Collapse
|