1
|
Lee MY, Lee D, Choi D, Kim KS, Kang PM. Targeting Reactive Oxygen Species for Diagnosis of Various Diseases. J Funct Biomater 2024; 15:378. [PMID: 39728178 DOI: 10.3390/jfb15120378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Revised: 12/12/2024] [Accepted: 12/12/2024] [Indexed: 12/28/2024] Open
Abstract
Reactive oxygen species (ROS) are generated predominantly during cellular respiration and play a significant role in signaling within the cell and between cells. However, excessive accumulation of ROS can lead to cellular dysfunction, disease progression, and apoptosis that can lead to organ dysfunction. To overcome the short half-life of ROS and the relatively small amount produced, various imaging methods have been developed, using both endogenous and exogenous means to monitor ROS in disease settings. In this review, we discuss the molecular mechanisms underlying ROS production and explore the methods and materials that could be used to detect ROS overproduction, including iron-based materials, ROS-responsive chemical bond containing polymers, and ROS-responsive molecule containing biomaterials. We also discuss various imaging and imaging techniques that could be used to target and detect ROS overproduction. We discuss the ROS imaging potentials of established clinical imaging methods, such as magnetic resonance imaging (MRI), sonographic imaging, and fluorescence imaging. ROS imaging potentials of other imaging methods, such as photoacoustic imaging (PAI) and Raman imaging (RI) that are currently in preclinical stage are also discussed. Finally, this paper focuses on various diseases that are associated with ROS overproduction, and the current and the future clinical applications of ROS-targeted imaging. While the most widely used clinical condition is cardiovascular diseases, its potential extends into non-cardiovascular clinical conditions, such as neurovascular, neurodegenerative, and other ROS-associated conditions, such as cancers, skin aging, acute kidney injury, and inflammatory arthritis.
Collapse
Affiliation(s)
- Moung Young Lee
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
- Centers for Research in ICT based Infectious Diseases, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Donguk Lee
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
- Massachusetts College of Pharmacy and Health Sciences, Boston, MA 02115, USA
| | - Dayun Choi
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
- Massachusetts College of Pharmacy and Health Sciences, Boston, MA 02115, USA
| | - Kye S Kim
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
| | - Peter M Kang
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
2
|
Carneiro LM, Bartoloni FH, Angolini CFF, Keppler AF. Solvent-free synthesis of nitrone-containing template as a chemosensor for selective detection of Cu(II) in water. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 267:120473. [PMID: 34715559 DOI: 10.1016/j.saa.2021.120473] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/21/2021] [Accepted: 10/04/2021] [Indexed: 06/13/2023]
Abstract
A state-of-the-art method was developed for repurposing nitrone-containing compounds in the chemosensory field, the ability of the designed molecules to chelate metal cations was evaluated, and their unprecedented solubility in water was confirmed. A facile, rapid, and solvent-free method of synthesizing small molecular mass chemosensors was developed by using a modulative α-aryl-N-aryl nitrone template. α-(Z)-Imidazol-4-ylmethylen-N-phenyl nitrone (Nit1) and α-(Z)-2-pyridyl-N-phenyl nitrone (Nit2) were prepared in 15 min, isolated in less than 60 min with ca. 90% yield, and screened against nine metal cations. Nit1 is a small-molecular-mass compound (188 g mol-1) that is water-soluble and has specificity for sensing Cu2+ with an association constant of K = 1.53 × 1010 and a limit of detection (LOD) of 0.06 ppm. These properties make Nit1 a competitive chemosensor for the detection of Cu2+ in aqueous solution. The nitrone-containing template used in this study is a step forward for new and small chemosensory entities.
Collapse
Affiliation(s)
- Leonardo M Carneiro
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Avenida dos Estados 5001, Santo André, SP ZIP CODE 09210-580, Brazil
| | - Fernando H Bartoloni
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Avenida dos Estados 5001, Santo André, SP ZIP CODE 09210-580, Brazil
| | - Célio F F Angolini
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Avenida dos Estados 5001, Santo André, SP ZIP CODE 09210-580, Brazil
| | - Artur F Keppler
- Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Avenida dos Estados 5001, Santo André, SP ZIP CODE 09210-580, Brazil.
| |
Collapse
|
3
|
Brender JR, Saida Y, Devasahayam N, Krishna MC, Kishimoto S. Hypoxia Imaging As a Guide for Hypoxia-Modulated and Hypoxia-Activated Therapy. Antioxid Redox Signal 2022; 36:144-159. [PMID: 34428981 PMCID: PMC8856011 DOI: 10.1089/ars.2021.0176] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 08/16/2021] [Indexed: 01/03/2023]
Abstract
Significance: Oxygen imaging techniques, which can probe the spatiotemporal heterogeneity of tumor oxygenation, could be of significant clinical utility in radiation treatment planning and in evaluating the effectiveness of hypoxia-activated prodrugs. To fulfill these goals, oxygen imaging techniques should be noninvasive, quantitative, and capable of serial imaging, as well as having sufficient temporal resolution to detect the dynamics of tumor oxygenation to distinguish regions of chronic and acute hypoxia. Recent Advances: No current technique meets all these requirements, although all have strengths in certain areas. The current status of positron emission tomography (PET)-based hypoxia imaging, oxygen-enhanced magnetic resonance imaging (MRI), 19F MRI, and electron paramagnetic resonance (EPR) oximetry are reviewed along with their strengths and weaknesses for planning hypoxia-guided, intensity-modulated radiation therapy and detecting treatment response for hypoxia-targeted prodrugs. Critical Issues: Spatial and temporal resolution emerges as a major concern for these areas along with specificity and quantitative response. Although multiple oxygen imaging techniques have reached the investigative stage, clinical trials to test the therapeutic effectiveness of hypoxia imaging have been limited. Future Directions: Imaging elements of the redox environment besides oxygen by EPR and hyperpolarized MRI may have a significant impact on our understanding of the basic biology of the reactive oxygen species response and may extend treatment possibilities.
Collapse
Affiliation(s)
- Jeffrey R. Brender
- Radiation Biology Branch, Center for Cancer Research, National
Institutes of Health, Bethesda, Maryland, USA
| | - Yu Saida
- Radiation Biology Branch, Center for Cancer Research, National
Institutes of Health, Bethesda, Maryland, USA
| | - Nallathamby Devasahayam
- Radiation Biology Branch, Center for Cancer Research, National
Institutes of Health, Bethesda, Maryland, USA
| | - Murali C. Krishna
- Radiation Biology Branch, Center for Cancer Research, National
Institutes of Health, Bethesda, Maryland, USA
| | - Shun Kishimoto
- Radiation Biology Branch, Center for Cancer Research, National
Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
4
|
Stewart NJ, Sato T, Takeda N, Hirata H, Matsumoto S. Hyperpolarized 13C Magnetic Resonance Imaging as a Tool for Imaging Tissue Redox State, Oxidative Stress, Inflammation, and Cellular Metabolism. Antioxid Redox Signal 2022; 36:81-94. [PMID: 34218688 PMCID: PMC8792501 DOI: 10.1089/ars.2021.0139] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Significance: Magnetic resonance imaging (MRI) with hyperpolarized (HP) 13C-labeled redox-sensitive metabolic tracers can provide noninvasive functional imaging biomarkers, reflecting tissue redox state, oxidative stress, and inflammation, among others. The capability to use endogenous metabolites as 13C-enriched imaging tracers without structural modification makes HP 13C MRI a promising tool to evaluate redox state in patients with various diseases. Recent Advances: Recent studies have demonstrated the feasibility of in vivo metabolic imaging of 13C-labeled tracers polarized by parahydrogen-induced polarization techniques, which offer a cost-effective alternative to the more widely used dissolution dynamic nuclear polarization-based hyperpolarizers. Critical Issues: Although the fluxes of many metabolic pathways reflect the change in tissue redox state, they are not functionally specific. In the present review, we summarize recent challenges in the development of specific 13C metabolic tracers for biomarkers of redox state, including that for detecting reactive oxygen species. Future Directions: Applications of HP 13C metabolic MRI to evaluate redox state have only just begun to be investigated. The possibility to gain a comprehensive understanding of the correlations between tissue redox potential and metabolism under different pathological conditions by using HP 13C MRI is promoting its interest in the clinical arena, along with its noninvasive biomarkers to evaluate the extent of disease and treatment response.
Collapse
Affiliation(s)
- Neil J Stewart
- Division of Bioengineering & Bioinformatics, Graduate School of Information Science & Technology, Hokkaido University, Sapporo, Japan.,POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Tatsuyuki Sato
- Division of Cardiology and Metabolism Center for Molecular Medicine, Jichi Medical University, Shimotsuke-shi, Japan.,Department of Cardiovascular Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.,Japan Society for the Promotion of Science, Tokyo, Japan
| | - Norihiko Takeda
- Division of Cardiology and Metabolism Center for Molecular Medicine, Jichi Medical University, Shimotsuke-shi, Japan
| | - Hiroshi Hirata
- Division of Bioengineering & Bioinformatics, Graduate School of Information Science & Technology, Hokkaido University, Sapporo, Japan
| | - Shingo Matsumoto
- Division of Bioengineering & Bioinformatics, Graduate School of Information Science & Technology, Hokkaido University, Sapporo, Japan
| |
Collapse
|
5
|
Real-Time insight into in vivo redox status utilizing hyperpolarized [1- 13C] N-acetyl cysteine. Sci Rep 2021; 11:12155. [PMID: 34108512 PMCID: PMC8190077 DOI: 10.1038/s41598-021-90921-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 05/10/2021] [Indexed: 01/27/2023] Open
Abstract
Drastic sensitivity enhancement of dynamic nuclear polarization is becoming an increasingly critical methodology to monitor real-time metabolic and physiological information in chemistry, biochemistry, and biomedicine. However, the limited number of available hyperpolarized 13C probes, which can effectively interrogate crucial metabolic activities, remains one of the major bottlenecks in this growing field. Here, we demonstrate [1-13C] N-acetyl cysteine (NAC) as a novel probe for hyperpolarized 13C MRI to monitor glutathione redox chemistry, which plays a central part of metabolic chemistry and strongly influences various therapies. NAC forms a disulfide bond in the presence of reduced glutathione, which generates a spectroscopically detectable product that is separated from the main peak by a 1.5 ppm shift. In vivo hyperpolarized MRI in mice revealed that NAC was broadly distributed throughout the body including the brain. Its biochemical transformation in two human pancreatic tumor cells in vitro and as xenografts differed depending on the individual cellular biochemical profile and microenvironment in vivo. Hyperpolarized NAC can be a promising non-invasive biomarker to monitor in vivo redox status and can be potentially translatable to clinical diagnosis.
Collapse
|
6
|
Abhyankar N, Szalai V. Challenges and Advances in the Application of Dynamic Nuclear Polarization to Liquid-State NMR Spectroscopy. J Phys Chem B 2021; 125:5171-5190. [PMID: 33960784 PMCID: PMC9871957 DOI: 10.1021/acs.jpcb.0c10937] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Nuclear magnetic resonance (NMR) spectroscopy is a powerful method to study the molecular structure and dynamics of materials. The inherently low sensitivity of NMR spectroscopy is a consequence of low spin polarization. Hyperpolarization of a spin ensemble is defined as a population difference between spin states that far exceeds what is expected from the Boltzmann distribution for a given temperature. Dynamic nuclear polarization (DNP) can overcome the relatively low sensitivity of NMR spectroscopy by using a paramagnetic matrix to hyperpolarize a nuclear spin ensemble. Application of DNP to NMR can result in sensitivity gains of up to four orders of magnitude compared to NMR without DNP. Although DNP NMR is now more routinely utilized for solid-state (ss) NMR spectroscopy, it has not been exploited to the same degree for liquid-state samples. This Review will consider challenges and advances in the application of DNP NMR to liquid-state samples. The Review is organized into four sections: (i) mechanisms of DNP NMR relevant to hyperpolarization of liquid samples; (ii) applications of liquid-state DNP NMR; (iii) available detection schemes for liquid-state samples; and (iv) instrumental challenges and outlook for liquid-state DNP NMR.
Collapse
Affiliation(s)
- Nandita Abhyankar
- Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20742, USA
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| | - Veronika Szalai
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| |
Collapse
|
7
|
Shoda S, Hyodo F, Tachibana Y, Kiniwa M, Naganuma T, Eto H, Koyasu N, Murata M, Matsuo M. Imaging of Hydroxyl-Radical Generation Using Dynamic Nuclear Polarization-Magnetic Resonance Imaging and a Spin-Trapping Agent. Anal Chem 2020; 92:14408-14414. [PMID: 33064938 DOI: 10.1021/acs.analchem.0c02331] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Reactive oxygen species (ROS) play an important role in cell metabolism, but they can cause oxidative damage to biomolecules. Among ROS, the hydroxyl radical (·OH) is one of the most reactive molecules in biological systems because of its high reaction rate constant. Therefore, imaging of ·OH could be useful for evaluation of the redox mechanism and diagnosis of oxidative diseases. In vivo dynamic nuclear polarization-magnetic resonance imaging (DNP-MRI) is a noninvasive imaging method to obtain spatiotemporal information about free radicals with MRI anatomical resolution. In this study, we investigated the visualization of hydroxyl radicals generated from the Fenton reaction by combining DNP-MRI with a spin-trapping agent (DMPO: 5,5-dimethyl-1-pyrroline N-oxide) for ·OH. Additionally, we demonstrated the radical-scavenging effect using four thiol-related reagents by DNP-MRI. We demonstrated that DNP enhancement could be induced by the DMPO-OH radical using the DNP-MRI/spin-trapping method and visualized ·OH generation for the first time. Maximum DNP enhancement was observed at an electron paramagnetic resonance irradiation frequency of 474.5 MHz. Furthermore, the radical-scavenging effect was simultaneously evaluated by the decrease in the DNP image value of DMPO-OH. An advantage of our methods is that they simultaneously investigate compound activity and the radical-scavenging effect.
Collapse
Affiliation(s)
- Shinichi Shoda
- Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan
| | - Fuminori Hyodo
- Department of Radiology, Frontier Science for Imaging, School of Medicine, Gifu University, Gifu 501-1194, Japan.,Innovation Center for Medical Redox Navigation, Kyushu University,3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Yoko Tachibana
- Innovation Center for Medical Redox Navigation, Kyushu University,3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.,Center for Advanced Medical Innovation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Mamoru Kiniwa
- Innovation Center for Medical Redox Navigation, Kyushu University,3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Tatsuya Naganuma
- Japan Redox Limited, Fukuoka, 4-29 Chiyo, Fukuoka 812-0044, Japan
| | - Hinako Eto
- Innovation Center for Medical Redox Navigation, Kyushu University,3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.,Center for Advanced Medical Innovation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Norikazu Koyasu
- Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan
| | - Masaharu Murata
- Innovation Center for Medical Redox Navigation, Kyushu University,3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.,Center for Advanced Medical Innovation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Masayuki Matsuo
- Department of Radiology, Gifu University, 1-1 Yanagido, Gifu 501-1194, Japan
| |
Collapse
|