Lee JW, Choi JY, Yoon H, Shin CM, Park YS, Kim N, Lee DH. Favorable outcomes of prepackaged low-residue diet on bowel preparation for colonoscopy: Endoscopist-blinded randomized controlled trial.
J Gastroenterol Hepatol 2019;
34:864-869. [PMID:
30278110 DOI:
10.1111/jgh.14499]
[Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 09/15/2018] [Accepted: 09/19/2018] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND AIM
2 L polyethylene glycol plus an ascorbic acid (PEGA) is known to be as effective. However, 2 L polyethylene glycol-based regimens are often still difficult for patients to tolerate. Therefore, we conducted this study to evaluate the potential of 1 L PEGA with prepackaged low-residue diet (PLD) as an alternative to 2 L PEGA before colonoscopy.
METHODS
The subjects were randomly assigned to either of the two groups. The 2 L PEGA group received 2 L PEGA split regimen. The 1 L PEGA with PLD group received PLD on the day preceding colonoscopy and 1 L PEGA. All endoscopic procedures were performed by one physician who did not know patients allocation. Bowel preparation status were graded using Boston Bowel Preparation Score (BBPS). A questionnaire regarding tolerability and safety was administered. This trial is registered at ClinicalTrials.gov (NCT03329339).
RESULTS
A total of 173 patients completed the study (86 in the 2 L PEGA group and 87 in the 1 L PEGA with PLD group). Bowel preparation was adequate in 88.4% (76/86) of patients in the 2 L PEGA group and 93.1% of patients in the 1 L PEGA with PLD group (81/87, P = 0.28). The patients in the 1 L PEGA with PLD group had higher whole Boston Bowel Preparation Scale score (P = 0.02) and expressed more satisfaction and willingness to repeat the procedure (P < 0.01). There was no significant difference with respect to compliance or safety.
CONCLUSION
1 L PEGA with PLD showed equivalent efficacy, greater satisfaction, and more willingness to repeat compared with 2 L PEGA for bowel preparation.
Collapse