1
|
Knoop RF, Amanzada A, Petzold G, Ellenrieder V, Engelhardt M, Neesse A, Bremer SCB, Kunsch S. Endoscopic mucosal resection and endoscopic submucosal dissection with an external additional working channel (EMR+ and ESD+) are equivalent to using a double-channel endoscope: a systematic evaluation in a porcine ex vivo model. Surg Endosc 2023; 37:7749-7758. [PMID: 37567979 PMCID: PMC10520185 DOI: 10.1007/s00464-023-10295-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 07/02/2023] [Indexed: 08/13/2023]
Abstract
BACKGROUND AND AIMS With an external additional working channel (AWC) endoscopic mucosal resection (EMR) as well as endoscopic submucosal dissection (ESD) can be extended to techniques termed "EMR+" and "ESD+." These novel techniques are systematically compared to EMR and ESD under the use of a double-channel endoscope (DC). METHODS Our trial was conducted prospectively in a pre-clinical porcine animal model (EASIE-R simulator) with standardized gastric lesions measuring 3 or 4 cm. RESULTS EMR+ and EMR DC showed both good results for 3 cm lesions with no adverse events and an en bloc resection rate of 73.33% (EMR+) and 60.00% (EMR DC, p = 0.70). They came to their limits in 4 cm lesions with muscularis damages of 20.00% (EMR+), 13.33% (EMR DC, p ≥ 0.99) and decreasing en bloc resection rates of 60.00% (EMR+) and 46.67% (EMR DC, p = 0.72). ESD+ and ESD DC were both reliable concerning en bloc resection rates (100% in all groups) and adverse events (0.00% in 3 cm lesions, 12.50% muscularis damages in both ESD+ and ESD DC in 4 cm lesions). Resection time was slightly shorter in all groups with the AWC compared to DC although only reaching significance in 3 cm ESD lesions (p < 0.05*). CONCLUSIONS With the AWC, a standard endoscope can easily be transformed to double-channel functionality. We could show that EMR+ and ESD+ are non-inferior to EMR and ESD under the use of a double-channel endoscope. Consequently, the AWC presents an affordable alternative to a double-channel endoscope for both EMR and ESD.
Collapse
Affiliation(s)
- Richard F Knoop
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany.
| | - Ahmad Amanzada
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Golo Petzold
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Michael Engelhardt
- Department of Gastroenterology, Internal Medicine and Geriatrics, Rems-Murr-Hospital, Winnenden, Germany
| | - Albrecht Neesse
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Sebastian C B Bremer
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Steffen Kunsch
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
- Department of Gastroenterology, Internal Medicine and Geriatrics, Rems-Murr-Hospital, Winnenden, Germany
| |
Collapse
|
2
|
Visrodia K, Dobashi A, Bazerbachi F, Poneros J, Sethi A. Endoscopic Submucosal Dissection Facilitating Techniques Among Non-experts: A Systematic Literature Review. Dig Dis Sci 2023; 68:2561-2584. [PMID: 37024739 DOI: 10.1007/s10620-022-07784-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Accepted: 11/30/2022] [Indexed: 04/08/2023]
Abstract
BACKGROUND AND AIMS The dissemination of endoscopic submucosal dissection (ESD) has been limited by its technical complexity and safety profile, particularly among non-experts. Various techniques and devices have facilitated the performance of ESD, but their yield and role in the path to learning ESD remain unclear. METHODS We performed a systematic review by querying MEDLINE, EMBASE, Web of Science, and Japan Medical Abstracts Society specifically for comparative studies investigating the impact of assigned ESD techniques vs. conventional techniques among non-experts in ESD (< 50 ESD procedures). Procedural outcomes of efficacy, efficiency, and safety were assessed. RESULTS We identified 46 studies evaluating 54 cohorts in which a total 237 non-experts performed 2461 ESDs conventionally, and 1953 ESDs using an assigned ESD technique (knives, countertraction, miscellaneous techniques). The majority of studies were from East Asia (67%), single-center (96%), observational in design (61%), in an animal model (57%), and gastric location (63%). The most studied techniques were countertraction techniques (48% cohorts) and scissor knives (15% cohorts), both of which commonly enhanced efficiency of ESD, and less so efficacy or safety. Techniques found to be beneficial in experts were more likely to be beneficial in non-experts (70% concordance) than vice versa (47% concordance). CONCLUSION Based on the currently available literature, countertraction techniques and scissor knives should be considered for early incorporation into ESD training by non-experts. Several aspects of ESD training remain understudied, including techniques in Western non-experts, educational resources, and several commonly cited techniques. These areas should guide future investigation to enhance the pathway to learning ESD.
Collapse
Affiliation(s)
- Kavel Visrodia
- Division of Digestive and Liver Diseases, Columbia University Irving Medical Center-New York Presbyterian Hospital, 161 Fort Washington Ave, 8th Fl, Ste 852A, New York, NY, 10032, USA.
| | - Akira Dobashi
- Department of Endoscopy, The Jikei University School of Medicine, Tokyo, Japan
| | - Fateh Bazerbachi
- CentraCare, Interventional Endoscopy Program, St Cloud Hospital, St Cloud, MN, USA
| | - John Poneros
- Division of Digestive and Liver Diseases, Columbia University Irving Medical Center-New York Presbyterian Hospital, 161 Fort Washington Ave, 8th Fl, Ste 852A, New York, NY, 10032, USA
| | - Amrita Sethi
- Division of Digestive and Liver Diseases, Columbia University Irving Medical Center-New York Presbyterian Hospital, 161 Fort Washington Ave, 8th Fl, Ste 852A, New York, NY, 10032, USA
| |
Collapse
|
3
|
Knoop RF, Wedi E, Petzold G, Bremer SCB, Amanzada A, Ellenrieder V, Neesse A, Kunsch S. Endoscopic submucosal dissection with an additional working channel (ESD+): a novel technique to improve procedure time and safety of ESD. Surg Endosc 2020; 35:3506-3512. [PMID: 32676726 PMCID: PMC8195965 DOI: 10.1007/s00464-020-07808-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 07/10/2020] [Indexed: 02/07/2023]
Abstract
Background and aims A new external additional working channel (AWC) was recently introduced by which endoscopic submucosal dissection (ESD) can be converted to a technique termed “ESD+ ”. We aim to systematically evaluate this novel technique in flat gastric lesions and compare it to classical ESD. Methods The study was prospectively conducted in a pre-clinical ex vivo animal model (EASIE-R simulator) with porcine stomachs. Prior to intervention, we set standardized lesions measuring 3 cm or 4 cm in antegrade as well as in retrograde positions. Results Overall, 64 procedures were performed by an experienced endoscopist. Both techniques were reliable and showed en bloc resection rates of 100%. Overall, ESD+ reduced time of procedure compared to ESD (24.5 vs. 32.5 min, p = 0.025*). Particularly, ESD+ was significantly faster in retrograde lesions with a median of 22.5 vs. 34.0 min in 3 cm retrograde lesions (p = 0.002*) and 34.5 vs. 41.0 min (p = 0.011*) in 4 cm retrograde lesions. There were 0 perforations with both techniques. In ESD+ , 1 muscularis damage occurred (3.13%) compared to 6 muscularis damages with ESD (18.75%, p = 0.045*). Conclusions By its grasp-and-mobilize technique, ESD+ allows potentially faster and safer resections of flat gastric lesions compared to conventional ESD in an ex vivo porcine model. The potential advantages of ESD+ in terms of procedure time may be particularly relevant for difficult lesions in retrograde positions. Electronic supplementary material The online version of this article (10.1007/s00464-020-07808-w) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Richard F Knoop
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Golo Petzold
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Sebastian C B Bremer
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Ahmad Amanzada
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Albrecht Neesse
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Steffen Kunsch
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany.
| |
Collapse
|
4
|
Wang F, Leng X, Gao Y, Zhao K, Sun Y, Bian H, Liu H, Liu P. Endoscopic submucosal dissection of distal intestinal tumors using grasping forceps for traction. Tech Coloproctol 2019; 23:1079-1083. [PMID: 31659559 DOI: 10.1007/s10151-019-02102-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Accepted: 10/15/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND The aim of this study was to assess the efficacy of traction device-assisted endoscopic submucosal dissection (ESD) of the rectum and the distal segment of sigmoid colon using grasping forceps. METHODS A total of 43 patients scheduled for colonic ESD at our institution were enrolled between January 2013 and June 2017. The patients were randomly allocated to receive conventional ESD (group A) or traction device-assisted ESD (group B). The procedure time, complication rate, and en-block resection rate in the two groups were compared. RESULTS A total of 41 patients completed the study. The procedure time, complication rate and en-block resection rate were, respectively, 104.1 ± 34.7 min, 15%, 90% in the routine group (group A) and 84.7 ± 23.5 min, 9.5%, 90.5% in traction device-assisted ESD (group B). The procedure time in group B was significantly less than that in group A (F = 4.442, p < 0.05). CONCLUSIONS Traction device-assisted ESD using grasping forceps is safe and effective in distal colon ESD.
Collapse
Affiliation(s)
- F Wang
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - X Leng
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - Y Gao
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - K Zhao
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - Y Sun
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - H Bian
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - H Liu
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China
| | - P Liu
- Xuzhou Medical University, No. 3 Yingrui Road, Jiangyin, China.
| |
Collapse
|
5
|
An internal magnet traction device reduces procedure time for endoscopic submucosal dissection by expert and non-expert endoscopists: ex vivo study in a porcine colorectal model (with video). Surg Endosc 2019; 33:2696-2703. [PMID: 31069502 DOI: 10.1007/s00464-019-06817-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 04/30/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND Efficacy of an internal magnet traction device (MTD) for gastric endoscopic submucosal dissection (ESD) by an expert endoscopist has been reported. We hypothesized that use of the MTD would enhance the performance of colorectal ESD in a non-expert endoscopist in ESD compared to the conventional technique. Primary aim of this study was to compare procedure times between conventional ESD (C-ESD) and MTD-assisted ESD (MTD-ESD) by expert and non-expert endoscopists in ESD. Secondary aims included rate of en bloc resection, iatrogenic injury, visualization score of the submucosal layer, and endoscopist satisfaction score. METHODS A total of 56 lesions were created in an ex vivo porcine colorectum. Two endoscopists completed C-ESD (n = 28) and MTD-ESD (n = 28). Lesions measured 3 cm in diameter and were located on either the anterior or posterior colorectal wall. The MTD consisted of a small neodymium magnet and nylon monofilament attached to a through-the-scope clip. The first MTD was deployed on the opposing colorectal wall of the target lesion and a second MTD was then deployed directly onto the distal margin of the lesion. RESULTS Total procedure time for MTD-ESD was significantly shorter than C-ESD for both expert (median: 15.8 vs. 19.3 min, p < 0.05) and non-expert (median: 21.3 vs. 33.9 min, p < 0.001) endoscopists. All lesions were resected en bloc. There was no iatrogenic muscularis propria injury in the MTD-ESD group. For both the expert and non-expert, scores for MTD-ESD were significantly higher for submucosal layer visualization (p < 0.05) and endoscopist satisfaction (p < 0.001) compared to C-ESD. CONCLUSIONS Use of the MTD significantly reduced procedure time for both expert and non-expert endoscopists performing ESD. Improving the efficiency, safety, and satisfaction of ESD with such a device particularly for non-expert endoscopists is appealing and could potentially minimize the complexity and duration of the procedure allowing for more widespread use of the technique.
Collapse
|
6
|
Gromski MA, Cohen J, Saito K, Gonzalez JM, Sawhney M, Kang C, Moore A, Matthes K. Learning colorectal endoscopic submucosal dissection: a prospective learning curve study using a novel ex vivo simulator. Surg Endosc 2017; 31:4231-4237. [PMID: 28281126 DOI: 10.1007/s00464-017-5484-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 02/16/2017] [Indexed: 12/15/2022]
Abstract
BACKGROUND Endoscopic submucosal dissection (ESD) is increasingly being used in Asia as a minimally invasive therapy to eradicate large laterally spreading superficial tumors in the colon. To date, the learning curve and effectiveness of ex vivo simulators in colonic ESD training remain unclear. The aim of the study is to determine the learning curve of colonic ESD in an ex vivo simulator. METHODS We conducted a prospective study of colon ESD in ex vivo porcine colons in a prototype simulator. Three endoscopists with prior experience in gastric ESD but with no experience in colonic ESD each performed 30 ESD resections on standardized lesions in the rectosigmoid and left colon of the porcine simulator. Procedure time, en bloc resection status, and perforation were recorded. RESULTS All 90 lesions were resected using the ESD technique. The mean time of procedure was 49.6 min (standard deviation 29.6 min). The aggregate rate of perforation was 14.4% and the aggregate rate of non-en bloc resection was 5.6%. Using a composite quality score integrating complications and procedural time, it was found that there was a significant difference between two local polynomial regression lines when using a cut-point at the 9th procedure (p = 0.04), reflecting the point at which most of the learning curve is traversed. CONCLUSIONS In this study, there were significant improvements realized in colonic ESD performance after 9 colon ESD procedures in ex vivo specimens. Although training will depend on endoscopist skill and expertise, we suggest at least 9 ex vivo procedures prior to moving to live animal or proctored training in colonic ESD.
Collapse
Affiliation(s)
- Mark A Gromski
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, 702 Rotary Circle, Suite 225, Indianapolis, IN, 46202, USA.
- Department of Medicine, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.
| | - Jonah Cohen
- Department of Medicine, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Kayoko Saito
- Department of Medicine, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
- Department of Gastroenterology, Medical Topia Soka Hospital, Soka, Japan
| | - Jean-Michel Gonzalez
- Department of Medicine, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
- Department of Gastroenterology, Aix-Marseille University, APHM, Hôpital Nord, Marseille, France
| | - Mandeep Sawhney
- Department of Medicine, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Changdon Kang
- Department of Medicine, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
- Department of Internal Medicine, Kangwon National University School of Medicine, Chuncheon, South Korea
| | - Andrew Moore
- Cambridge Health Alliance, Harvard Medical School, Cambridge, MA, USA
| | - Kai Matthes
- Department of Anesthesia, Critical Care and Pain Medicine, Children's Hospital, Harvard Medical School, Boston, MA, USA
- T.A.M.G.I., Maui, HI, USA
| |
Collapse
|
7
|
Prospective, Randomized Ex Vivo Trial to Assess the Ideal Stapling Site for Endoscopic Fundoplication with Medigus Ultrasonic Surgical Endostapler. Gastroenterol Res Pract 2016; 2016:3161738. [PMID: 27547219 PMCID: PMC4983363 DOI: 10.1155/2016/3161738] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Accepted: 07/11/2016] [Indexed: 12/14/2022] Open
Abstract
Background and Aims. Endoscopic fundoplication is an emerging technique for the treatment of gastroesophageal reflux disease (GERD). The aim of this study is to determine the ideal position of the staples in relation to gastroesophageal junction (GEJ). Methods. Ten endoscopic fundoplication procedures were performed in each group using fresh ex vivo porcine stomachs: Group A: 2 staples each at 3 cm above the GEJ and 180° apart; Group B: 2 staples at 3 cm and 90° apart; Group C: 2 staples at 4 cm and 180° apart; Group D: 3 staples at 3 cm with 90° between each staple (180° total). After the procedure, the stomach was gradually filled with water. Gastric yield pressure (GYP) was determined by detection of reflux of the water in esophagus or by rupture of staples. Results. Mean increase of GYPs (±SD) after the procedure was as follows: Group A: 16.9 ± 8.7; Group B: 8.1 ± 7.9; Group C: 12.2 ± 9.4; Group D: 22.7 ± 13.3. GYP in Group A and Group D was higher than Group B (p = 0.03 and p = 0.01, resp.). Conclusions. We recommend the placement of 3 staples at 3 cm distance from the GEJ, which resulted in the highest increase of GYP.
Collapse
|
8
|
Kantsevoy SV, Bitner M, Piskun G. New endoscopic platform for endoluminal en bloc tissue resection in the gastrointestinal tract (with videos). Surg Endosc 2015; 30:3145-51. [PMID: 26514139 DOI: 10.1007/s00464-015-4544-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Accepted: 09/01/2015] [Indexed: 12/20/2022]
Abstract
BACKGROUND Endoscopic removal of gastrointestinal tract lesions is increasingly popular around the world. We evaluated feasibility, safety, effectiveness, and user learning curve of new endoscopic platform for complex intraluminal interventions. METHODS A novel system, consisting of expandable working chamber with two independent instrument guides (LIG), was inserted into colon. Simulated colonic lesions were removed with endoscopic submucosal (ESD) and submuscular (ESmD) dissection. RESULTS In all nine in vivo models, an intraluminal chamber and its dynamic tissue retractors (via LIG) provided a stable working space with excellent visualization and adequate access to target tissue. Endoscopic platform facilitated successful completion of 11 en bloc ESDs (mean size 43.0 ± 11.3 mm, mean time 46.3 ± 41.2 min) and eight ESmD (mean size 50.0 ± 14.1 mm, mean time 48.0 ± 21.2 min). The learning curve for ESD using this platform demonstrated three phases: rapid improvement in procedural skills took place during the first three procedures (mean ESD time 98.7 ± 40.0 min). A plateau phase then occurred (procedures 4-7) with mean procedure time 42.0 ± 13.4 min (p = 0.04), followed by another sharp improvement in procedural skills (procedures 8-11) requiring only 16.3 ± 11.4 min (p = 0.03) to complete ESD. Especially dramatic (p = 0.002) was the time difference between the first three procedures (mean time 98.7 ± 40.0 min) and subsequent eight procedures (mean time 29.1 ± 17.9 min). CONCLUSIONS A newly developed endoscopic platform provides stable intraluminal working space, dynamic tissue retraction, and instrument triangulation, improving visualization and access to the target tissue for safer and more effective en bloc endoscopic submucosal and submuscular dissection. The learning curve for ESD was markedly facilitated by this new endoscopic platform.
Collapse
Affiliation(s)
- Sergey V Kantsevoy
- Institute for Digestive Health and Liver Diseases, Mercy Medical Center, 301 St. Paul Place, POB 7th Floor, Suite 718, Baltimore, MD, 21202, USA.
- University of Maryland School of Medicine, Baltimore, MD, USA.
| | - Marianne Bitner
- Institute for Digestive Health and Liver Diseases, Mercy Medical Center, 301 St. Paul Place, POB 7th Floor, Suite 718, Baltimore, MD, 21202, USA
| | | |
Collapse
|
9
|
Feasibility and Safety of Endoscopic Submucosal Dissection for Large Colorectal Tumors. Surg Laparosc Endosc Percutan Tech 2015; 25:223-8. [DOI: 10.1097/sle.0000000000000135] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|