Aebischer P, Anschuetz L, Caversaccio M, Mantokoudis G, Weder S. Quantitative in-vitro assessment of a novel robot-assisted system for cochlear implant electrode insertion. Int J Comput Assist Radiol Surg 2025; 20:323-332. [PMID: 39352456 PMCID: PMC11807918 DOI: 10.1007/s11548-024-03276-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Accepted: 09/11/2024] [Indexed: 02/11/2025]
Abstract
PURPOSE As an increasing number of cochlear implant candidates exhibit residual inner ear function, hearing preservation strategies during implant insertion are gaining importance. Manual implantation is known to induce traumatic force and pressure peaks. In this study, we use a validated in-vitro model to comprehensively evaluate a novel surgical tool that addresses these challenges through motorized movement of a forceps. METHODS Using lateral wall electrodes, we examined two subgroups of insertions: 30 insertions were performed manually by experienced surgeons, and another 30 insertions were conducted with a robot-assisted system under the same surgeons' supervision. We utilized a realistic, validated model of the temporal bone. This model accurately reproduces intracochlear frictional conditions and allows for the synchronous recording of forces on intracochlear structures, intracochlear pressure, and the position and deformation of the electrode array within the scala tympani. RESULTS We identified a significant reduction in force variation during robot-assisted insertions compared to the conventional procedure, with average values of 12 mN/s and 32 mN/s, respectively. Robotic assistance was also associated with a significant reduction of strong pressure peaks and a 17 dB reduction in intracochlear pressure levels. Furthermore, our study highlights that the release of the insertion tool represents a critical phase requiring surgical training. CONCLUSION Robotic assistance demonstrated more consistent insertion speeds compared to manual techniques. Its use can significantly reduce factors associated with intracochlear trauma, highlighting its potential for improved hearing preservation. Finally, the system does not mitigate the impact of subsequent surgical steps like electrode cable routing and cochlear access sealing, pointing to areas in need of further research.
Collapse
Affiliation(s)
- Philipp Aebischer
- Hearing Research Laboratory, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, 3008, Switzerland.
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, 3010, Bern, Switzerland.
| | - Lukas Anschuetz
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, 3010, Bern, Switzerland
- Department of Otorhinolaryngology, Head and Neck Surgery, Lausanne University Hospital (CHUV), University of Lausanne, 1011, Lausanne, Switzerland
- The Sense Innovation and Research Center, 1011, Lausanne and Sion, Switzerland
| | - Marco Caversaccio
- Hearing Research Laboratory, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, 3008, Switzerland
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, 3010, Bern, Switzerland
| | - Georgios Mantokoudis
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, 3010, Bern, Switzerland
| | - Stefan Weder
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, 3010, Bern, Switzerland
| |
Collapse
|
2
|
Aebischer P, Sarbach B, Weder S, Mantokoudis G, Caversaccio M, Anschuetz L. Development and Evaluation of a Reusable, Force Measuring Tool for the Robot-Assisted Insertion of Cochlear Implant Electrode Arrays. IEEE Trans Biomed Eng 2025; 72:381-387. [PMID: 38995714 DOI: 10.1109/tbme.2024.3386723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/14/2024]
Abstract
OBJECTIVE Limitations in human kinematics during cochlear implantation induce pressure transients and increased forces on intracochlear structures. Herein, we present a novel head-mounted surgical tool designed for the motorized insertion of cochlear implant electrode arrays. The tool integrates a force measurement feature to overcome the lack of haptic feedback in current robotic solutions. METHODS Utilizing a prototype device, we compare force measurements with those exerted on intracochlear structures in a realistic temporal bone model. Furthermore, we test the tool on six temporal bone specimens in a surgical setting to assess its performance in various anatomies. RESULTS Force measurements exhibit good agreement with intracochlear forces, offering significantly improved resolution over manual, tactile sensing. Successful electrode array insertions in six cadaver specimens affirmed the feasibility of tool setup, motorized insertion and tool removal in different anatomies. CONCLUSION The tool allows the robot-assisted insertion of cochlear implant electrode arrays and offers valuable insights during the surgical procedure, demonstrating promise for application in clinical contexts. SIGNIFICANCE This instrument has the potential to aid surgeons in achieving atraumatic placement of electrodes, consequently contributing to the improvement of hearing outcomes in cochlear implantation.
Collapse
|
3
|
Cramer J, Böttcher-Rebmann G, Lenarz T, Rau TS. A method for accurate and reproducible specimen alignment for insertion tests of cochlear implant electrode arrays. Int J Comput Assist Radiol Surg 2024; 19:1883-1893. [PMID: 37204650 PMCID: PMC11582122 DOI: 10.1007/s11548-023-02930-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 04/19/2023] [Indexed: 05/20/2023]
Abstract
PURPOSE The trajectory along which the cochlear implant electrode array is inserted influences the insertion forces and the probability for intracochlear trauma. Controlling the trajectory is especially relevant for reproducible conditions in electrode insertion tests. Using ex vivo cochlear specimens, manual alignment of the invisibly embedded cochlea is imprecise and hardly reproducible. The aim of this study was to develop a method for creating a 3D printable pose setting adapter to align a specimen along a desired trajectory toward an insertion axis. METHODS Planning points of the desired trajectory into the cochlea were set using CBCT images. A new custom-made algorithm processed these points for automated calculation of a pose setting adapter. Its shape ensures coaxial positioning of the planned trajectory to both the force sensor measuring direction and the insertion axis. The performance of the approach was evaluated by dissecting and aligning 15 porcine cochlear specimens of which four were subsequently used for automated electrode insertions. RESULTS The pose setting adapter could easily be integrated into an insertion force test setup. Its calculation and 3D printing was possible in all 15 cases. Compared to planning data, a mean positioning accuracy of 0.21 ± 0.10 mm at the level of the round window and a mean angular accuracy of 0.43° ± 0.21° were measured. After alignment, four specimens were used for electrode insertions, demonstrating the practical applicability of our method. CONCLUSION In this work, we present a new method, which enables automated calculation and creation of a ready-to-print pose setting adapter for alignment of cochlear specimens in insertion test setups. The approach is characterized by a high level of accuracy and reproducibility in controlling the insertion trajectory. Therefore, it enables a higher degree of standardization in force measurement when performing ex vivo insertion tests and thereby improves reliability in electrode testing.
Collapse
Affiliation(s)
- Jakob Cramer
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
| | - Georg Böttcher-Rebmann
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
- Cluster of Excellence EXC 2177/1 "Hearing4all", Hannover Medical School, Hannover, Germany
| | - Thomas S Rau
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
- Cluster of Excellence EXC 2177/1 "Hearing4all", Hannover Medical School, Hannover, Germany
| |
Collapse
|
4
|
Harte N, Obrist D, Caversaccio M, Lajoinie G, Wimmer W. Transverse flow under oscillating stimulation in helical square ducts with cochlea-like geometrical curvature and torsion. EUROPEAN JOURNAL OF MECHANICS. B, FLUIDS 2024; 107:165-174. [PMID: 39220585 PMCID: PMC11327769 DOI: 10.1016/j.euromechflu.2024.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 05/24/2024] [Accepted: 07/01/2024] [Indexed: 09/04/2024]
Abstract
The cochlea, situated within the inner ear, is a spiral-shaped, liquid-filled organ responsible for hearing. The physiological significance of its shape remains uncertain. Previous research has scarcely addressed the occurrence of transverse flow within the cochlea, particularly in relation to its unique shape. This study aims to investigate the impact of the geometric features of the cochlea on fluid dynamics by characterizing transverse flow induced by harmonically oscillating axial flow in square ducts with curvature and torsion resembling human cochlear anatomy. We examined four geometries to investigate curvature and torsion effects on axial and transverse flow components. Twelve frequencies from 0.125 Hz to 256 Hz were studied, covering infrasound and low-frequency hearing, with mean inlet velocity amplitudes representing levels expected for normal conversation or louder situations. Our simulations show that torsion contributes significantly to transverse flow in unsteady conditions, and that its contribution increases with increasing oscillation frequency. Curvature alone has a small effect on transverse flow strength, which decreases rapidly with increasing frequency. Strikingly, the combined effect of curvature and torsion on transverse flow is greater than expected from a simple superposition of the two effects, especially when the relative contribution of curvature alone becomes negligible. These findings may be relevant to understanding physiological processes in the cochlea, including metabolite transport and wall shear stress. Further studies are needed to investigate possible implications for cochlear mechanics.
Collapse
Affiliation(s)
- N.C. Harte
- Department of Otorhinolaryngology, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - D. Obrist
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - M. Caversaccio
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
- Department of Otorhinolaryngology, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - G.P.R. Lajoinie
- Physics of Fluids Group, Max Planck Center for Complex Fluid Dynamics, Technical Medical (TechMed) Center, University of Twente, Enschede, The Netherlands
| | - W. Wimmer
- Department of Otorhinolaryngology, TUM School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- Department of Otorhinolaryngology, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
5
|
Amstutz C, Ilic M, Fontaine N, Siegenthaler L, Illi J, Haeberlin A, Zurbuchen A, Burger J. Development of a patient-specific model of the human coronary system for percutaneous transluminal coronary angioplasty balloon catheter training and testing. Biomed Eng Online 2024; 23:89. [PMID: 39215308 PMCID: PMC11363638 DOI: 10.1186/s12938-024-01271-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 07/22/2024] [Indexed: 09/04/2024] Open
Abstract
BACKGROUND To treat stenosed coronary arteries, percutaneous transluminal coronary angioplasty (PTCA) balloon catheters must combine pushability, trackability, crossability, and rewrap behavior. The existing anatomic track model (ASTM F2394) for catheter testing lacks 3D morphology, vessel tortuosity, and compliance, making evaluating performance characteristics difficult. This study aimed to develop a three-dimensional patient-specific phantom (3DPSP) for device testing and safe training for interventional cardiologists. METHODS A range of silicone materials with different shore hardnesses (00-30-45 A) and wall thicknesses (0.5 mm, 1 mm, 2 mm) were tested to determine compliance for creating coronary vessel phantoms. Compliance was assessed using optical coherence tomography (OCT) and compared to values in the literature. Stenosis was induced using multilayer casting and brushing methods, with gypsum added for calcification. The radial tensile properties of the samples were investigated, and the relationship between Young's modulus and compliance was determined. Various methods have been introduced to approximate the friction between silicone and real coronary vessel walls. Computerized tomography (CT) scans were used to obtain patient-specific anatomy from the femoral artery to the coronary arteries. Artery lumens were segmented from the CT scans to create dissolvable 3D-printed core models. RESULTS A 15A shore hardness silicone yielded an experimental compliance of 12.3-22.4m m 2 mmHg · 10 3 for stenosed tubes and 14.7-57.9m m 2 mmHg · 10 3 for uniform tubes, aligning closely with the literature data (6.28-40.88m m 2 mmHg · 10 3 ). The Young's modulus ranged from 43.2 to 75.5 kPa and 56.6-67.9 kPa for the uniform and calcified materials, respectively. The dependency of the compliance on the wall thickness, Young's modulus, and inner diameter could be shown. Introducing a lubricant reduced the silicone friction coefficient from 0.52 to 0.13. The 3DPSP was successfully fabricated, and comparative analyses were conducted among eight commercially available catheters. CONCLUSION This study presents a novel method for crafting 3DPSPs with realistic mechanical and frictional properties. The proposed approach enables the creation of comprehensive and anatomically precise setups spanning the right femoral artery to the coronary arteries, highlighting the importance of such realistic environments for advancing medical device development and fostering safe training conditions.
Collapse
Affiliation(s)
- C Amstutz
- School of Biomedical and Precision Engineering, Faculty of Medicine, University of Bern, Güterstrasse 24/26, CH-3010, Bern, Switzerland.
| | - M Ilic
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - N Fontaine
- School of Biomedical and Precision Engineering, Faculty of Medicine, University of Bern, Güterstrasse 24/26, CH-3010, Bern, Switzerland
| | - L Siegenthaler
- School of Biomedical and Precision Engineering, Faculty of Medicine, University of Bern, Güterstrasse 24/26, CH-3010, Bern, Switzerland
| | - J Illi
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - A Haeberlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - A Zurbuchen
- School of Biomedical and Precision Engineering, Faculty of Medicine, University of Bern, Güterstrasse 24/26, CH-3010, Bern, Switzerland
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - J Burger
- School of Biomedical and Precision Engineering, Faculty of Medicine, University of Bern, Güterstrasse 24/26, CH-3010, Bern, Switzerland
| |
Collapse
|
6
|
Fröhlich M, Deutz J, Wangenheim M, Rau TS, Lenarz T, Kral A, Schurzig D. The role of pressure and friction forces in automated insertion of cochlear implants. Front Neurol 2024; 15:1430694. [PMID: 39170077 PMCID: PMC11337231 DOI: 10.3389/fneur.2024.1430694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 07/24/2024] [Indexed: 08/23/2024] Open
Abstract
Objectives Despite the success of cochlear implant (CI) surgery for hearing restoration, reducing CI electrode insertion forces is an ongoing challenge with the goal to further reduce post-implantation hearing loss. While research in this field shows that both friction and quasistatic pressure forces occur during CI insertion, there is a lack of studies distinguishing between these origins. The present study was conducted to analyze the contribution of both force phenomena during automated CI insertion. Methods Five MED-EL FLEX28 CI electrode arrays were inserted into both a regular and uncoiled version of the same average scala tympani (ST). Both ST models had a pressure release hole at the apical end, which was kept open or closed to quantify pressure forces. ST models were filled with different sodium dodecyl sulfate (SDS) lubricants (1, 5, and 10% SDS, water). The viscosity of lubricants was determined using a rheometer. Insertions were conducted with velocities ranging from v= 0.125 mm/s to 2.0 mm/s. Results Viscosity of SDS lubricants at 20°C was 1.28, 1.96, and 2.51 mPas for 1, 5, and 10% SDS, respectively, which lies within the values reported for human perilymph. In the uncoiled ST model, forces remained within the noise floor (maximum: 0.049 × 10-3 N ± 1.5 × 10-3 N), indicating minimal contribution from quasistatic pressure. Conversely, forces using the regular, coiled ST model were at least an order of magnitude larger (minimum: Fmax = 28.95 × 10-3 N, v = 1 mm/s, 10% SDS), confirming that friction forces are the main contributor to total insertion forces. An N-way ANOVA revealed that both lubricant viscosity and insertion speed significantly reduce insertion forces (p < 0.001). Conclusion For the first time, this study demonstrates that at realistic perilymph viscosities, quasistatic pressure forces minimally affect the total insertion force profile during insertion. Mixed friction is the main determinant, and significantly decreases with increaseing insertion speeds. This suggests that in clinical settings with similar ST geometries and surgical preparation, quasistatic pressure plays a subordinate role. Moreover, the findings indicate that managing the hydrodynamics of the cochlear environment, possibly through pre-surgical preparation or the use of specific lubricants, could effectively reduce insertion forces.
Collapse
Affiliation(s)
- Max Fröhlich
- MED-EL Research Center, MED-EL Medical Electronics GmbH, Hannover, Germany
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany
| | - Jaro Deutz
- MED-EL Research Center, MED-EL Medical Electronics GmbH, Hannover, Germany
- Institute of Dynamic and Vibration Research, Leibniz University Hannover, Hannover, Germany
| | - Matthias Wangenheim
- Institute of Dynamic and Vibration Research, Leibniz University Hannover, Hannover, Germany
| | - Thomas S. Rau
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany
| | - Andrej Kral
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany
| | - Daniel Schurzig
- MED-EL Research Center, MED-EL Medical Electronics GmbH, Hannover, Germany
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany
| |
Collapse
|
7
|
Hrnčiřík F, Nagy L, Grimes HL, Iftikhar H, Muzaffar J, Bance M. Impact of Insertion Speed, Depth, and Robotic Assistance on Cochlear Implant Insertion Forces and Intracochlear Pressure: A Scoping Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:3307. [PMID: 38894099 PMCID: PMC11174543 DOI: 10.3390/s24113307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/13/2024] [Accepted: 05/14/2024] [Indexed: 06/21/2024]
Abstract
Cochlear implants are crucial for addressing severe-to-profound hearing loss, with the success of the procedure requiring careful electrode placement. This scoping review synthesizes the findings from 125 studies examining the factors influencing insertion forces (IFs) and intracochlear pressure (IP), which are crucial for optimizing implantation techniques and enhancing patient outcomes. The review highlights the impact of variables, including insertion depth, speed, and the use of robotic assistance on IFs and IP. Results indicate that higher insertion speeds generally increase IFs and IP in artificial models, a pattern not consistently observed in cadaveric studies due to variations in methodology and sample size. The study also explores the observed minimal impact of robotic assistance on reducing IFs compared to manual methods. Importantly, this review underscores the need for a standardized approach in cochlear implant research to address inconsistencies and improve clinical practices aimed at preserving hearing during implantation.
Collapse
Affiliation(s)
- Filip Hrnčiřík
- Cambridge Hearing Group, Cambridge CB2 7EF, UK; (F.H.)
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Leo Nagy
- Clinical School, University of Cambridge, Cambridge CB2 0QQ, UK
| | | | - Haissan Iftikhar
- Department of Otolaryngology, University Hospitals Birmingham, Birmingham B15 2TT, UK
| | - Jameel Muzaffar
- Cambridge Hearing Group, Cambridge CB2 7EF, UK; (F.H.)
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
- Department of Otolaryngology, University Hospitals Birmingham, Birmingham B15 2TT, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge CB2 7EF, UK; (F.H.)
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| |
Collapse
|
8
|
Aebischer P, Weder S, Vischer M, Mantokoudis G, Caversaccio M, Wimmer W. Uncovering Vulnerable Phases in Cochlear Implant Electrode Array Insertion: Insights from an In Vitro Model. Otol Neurotol 2024; 45:e271-e280. [PMID: 38346807 DOI: 10.1097/mao.0000000000004130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
OBJECTIVES The aim of this study is to improve our understanding of the mechanics involved in the insertion of lateral wall cochlear implant electrode arrays. DESIGN A series of 30 insertion experiments were conducted by three experienced surgeons. The experiments were carried out in a previously validated artificial temporal bone model according to established soft surgery guidelines. The use of an in vitro setup enabled us to comprehensively evaluate relevant parameters, such as insertion force, intracochlear pressure, and exact electrode array position in a controlled and repeatable environment. RESULTS Our findings reveal that strong intracochlear pressure transients are more frequently caused during the second half of the insertion, and that regrasping the electrode array is a significant factor in this phenomenon. For choosing an optimal insertion speed, we show that it is crucial to balance slow movement to limit intracochlear stress with short duration to limit tremor-induced pressure spikes, challenging the common assumption that a slower insertion is inherently better. Furthermore, we found that intracochlear stress is affected by the order of execution of postinsertion steps, namely sealing the round window and posterior tympanotomy with autologous tissue and routing of the excess cable into the mastoid cavity. Finally, surgeons' subjective estimates of physical parameters such as speed, smoothness, and resistance did not correlate with objectively assessed measures, highlighting that a thorough understanding of intracochlear mechanics is essential for an atraumatic implantation. CONCLUSION The results presented in this article allow us to formulate evidence-based surgical recommendations that may ultimately help to improve surgical outcome and hearing preservation in cochlear implant patients.
Collapse
Affiliation(s)
| | - Stefan Weder
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, Switzerland
| | - Mattheus Vischer
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, Switzerland
| | - Georgios Mantokoudis
- Department for Otolaryngology, Head and Neck Surgery, Inselspital University Hospital Bern, Switzerland
| | | | | |
Collapse
|
9
|
Fröhlich M, Schurzig D, Rau TS, Lenarz T. On the interdependence of insertion forces, insertion speed, and lubrication: Aspects to consider when testing cochlear implant electrodes. PLoS One 2024; 19:e0295121. [PMID: 38266033 PMCID: PMC10807833 DOI: 10.1371/journal.pone.0295121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 11/14/2023] [Indexed: 01/26/2024] Open
Abstract
OBJECTIVES During the insertion of cochlear implant (CI) electrode arrays, forces occur which may cause trauma and poorer hearing outcomes. Unfortunately, research groups investigating factors influencing insertion forces come to contradicting results, especially regarding insertion speed. This study was conducted to investigate the origin of these contradicting results and to determine how different testing conditions influence experimental findings. METHODS Repeated, automated insertions with three different FLEX28 CI electrode arrays (MED-EL, Innsbruck, Austria) were performed into a newly developed, anatomically correct and 3D-printed mean scala tympani phantom. The testing protocol for each electrode included variations in insertion speed (v = 0.1-2.0 mm/s) and lubrication (90%, 50%, and 10% liquid soap), resulting in 51 insertions per electrode array and a total of 153 insertions. RESULTS The test setup and protocol allowed for repeatable insertions with only minimal change in the morphology of the insertion force profiles per testing condition. Strong but varying dependencies of the maximal insertion forces and work were found regarding both lubrication and speed: work-speed dependency is constant for the 10% lubricant, negative for the 50% lubricant and positive for the 90% lubricant. CONCLUSION Our results can explain part of the contradicting results found within previous studies by translating interrelations known from lubricated rubber friction to the field of CI electrode array insertion. We show that the main driver behind measured bulk forces are most likely the generated friction forces, which are strongly dependent on insertion speed and lubrication. The employed test setup allows for conducting repeatable and comparable insertion studies, which can be recapitulated by other centers due to the detailed explanation of the test setup as well as the developed and freely available insertion phantom. This study hence represents another important step toward standardizing CI array insertion testing.
Collapse
Affiliation(s)
- Max Fröhlich
- MED-EL Medical Electronics GmbH, MED-EL Research Center, Hannover, Germany
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Daniel Schurzig
- MED-EL Medical Electronics GmbH, MED-EL Research Center, Hannover, Germany
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Thomas S. Rau
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover, Germany
| |
Collapse
|
10
|
Harte NC, Obrist D, Caversaccio MD, Lajoinie GPR, Wimmer W. Wall Shear Stress and Pressure Fluctuations under Oscillating Stimulation in Helical Square Ducts with Cochlea-like Geometrical Curvature and Torsion . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-7. [PMID: 38083665 DOI: 10.1109/embc40787.2023.10340844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Our study aims to provide basic insights on the impact of the spiral shape of the cochlea, i.e., of geometric torsion and curvature, on wall pressure and wall shear stress. We employed computational fluid dynamics in square duct models with curvature and torsion similar to those found in human cochleae. The results include wall pressures and wall shear stresses within the ducts under oscillating axial flow. Our findings indicate that the helical shape generates higher transverse wall shear stresses compared to exclusively curved or twisted ducts. The wall pressures and transverse wall shear stresses we found rise to amounts that may be physiologically relevant in the cochlea.Clinical relevance- The role of the spiral shape of the cochlea in hearing physiology remains, for a large part, elusive. For a better apprehension of hearing and its disorders, it is important to investigate the influence of geometric properties on biofluids motion and emerging phenomena in the cochlea.
Collapse
|
11
|
Starovoyt A, Shaheen E, Putzeys T, Kerckhofs G, Politis C, Wouters J, Verhaert N. Anatomically and mechanically accurate scala tympani model for electrode insertion studies. Hear Res 2023; 430:108707. [PMID: 36773540 DOI: 10.1016/j.heares.2023.108707] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 11/25/2022] [Accepted: 01/24/2023] [Indexed: 01/26/2023]
Abstract
The risk of insertion trauma in cochlear implantation is determined by the interplay between individual cochlear anatomy and electrode insertion mechanics. Whereas patient anatomy cannot be changed, new surgical techniques, devices for cochlear monitoring, drugs, and electrode array designs are continuously being developed and tested, to optimize the insertion mechanics and prevent trauma. Preclinical testing of these developments is a crucial step in feasibility testing and optimization for clinical application. Human cadaveric specimens allow for the best simulation of an intraoperative setting. However, their availability is limited and it is not possible to conduct repeated, controlled experiments on the same sample. A variety of artificial cochlear models have been developed for electrode insertion studies, but none of them were both anatomically and mechanically representative for surgical insertion into an individual cochlea. In this study, we developed anatomically representative models of the scala tympani for surgical insertion through the round window, based on microCT images of individual human cochleae. The models were produced in transparent material using commonly-available 3D printing technology at a desired scale. The anatomical and mechanical accuracy of the produced models was validated by comparison with human cadaveric cochleae. Mechanical evaluation was performed by recording insertion forces, counting the number of inserted electrodes and grading tactile feedback during manual insertion of a straight electrode by experienced cochlear implant surgeons. Our results demonstrated that the developed models were highly representative for the anatomy of the original cochleae and for the insertion mechanics in human cadaveric cochleae. The individual anatomy of the produced models had a significant impact on the insertion mechanics. The described models have a promising potential to accelerate preclinical development and testing of atraumatic insertion techniques, reducing the need for human cadaveric material. In addition, realistic models of the cochlea can be used for surgical training and preoperative planning of patient-tailored cochlear implantation surgery.
Collapse
Affiliation(s)
- Anastasiya Starovoyt
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium
| | - Eman Shaheen
- OMFS IMPATH Research Group, Department of Imaging and Pathology, KU Leuven, University of Leuven, Leuven, Belgium; Department of Oral and Maxillofacial Surgery, UZ Leuven, University Hospitals Leuven, Leuven, Belgium
| | - Tristan Putzeys
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium; Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, University of Leuven, Leuven, Belgium
| | - Greet Kerckhofs
- Biomechanics lab, Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium; Department of Materials Engineering, KU Leuven, University of Leuven, Leuven, Belgium; IREC, Institute of Experimental and Clinical Research, UCLouvain, Woluwé-Saint-Lambert, Belgium; Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, University of Leuven, Leuven, Belgium
| | - Constantinus Politis
- OMFS IMPATH Research Group, Department of Imaging and Pathology, KU Leuven, University of Leuven, Leuven, Belgium; Department of Oral and Maxillofacial Surgery, UZ Leuven, University Hospitals Leuven, Leuven, Belgium
| | - Jan Wouters
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium
| | - Nicolas Verhaert
- Research Group Experimental Oto-Rhino-Laryngology, Department of Neurosciences, KU Leuven, University of Leuven, Leuven, Belgium; Leuven Brain Institute, Department of Neurosciences, KU Leuven, 3000 Leuven, Belgium; Department of Otorhinolaryngology, Head and Neck Surgery, UZ Leuven, University Hospitals of Leuven, Leuven, Belgium.
| |
Collapse
|
12
|
Polymeric fiber sensors for insertion forces and trajectory determination of cochlear implants in hearing preservation. Biosens Bioelectron 2023; 222:114866. [PMID: 36463651 DOI: 10.1016/j.bios.2022.114866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/11/2022] [Accepted: 10/26/2022] [Indexed: 11/06/2022]
Abstract
The level of hearing restoration in patients with severe to profound sensorineural hearing loss by means of cochlear implants (CIs) has drastically risen since the introduction of these neuroprosthetics. The proposed CI integrated with polymer optical fiber Bragg gratings (POFBGs) enables real-time evaluation of insertion forces and trajectory determination during implantation irrespective of the speed of insertion, as well as provides high signal quality, low stiffness levels, minimum induced stress even under forces of high magnitudes and exhibits significant reduction of the risk of fiber breakage inside the constricted cochlear geometry. As such, the proposed device opens new avenues towards atraumatic cochlear implantations and provides a direct route for the next generation of CIs with intraoperative insertion force assessment and path planning capacity crucial for surgical navigation. Hence, adaptation of this technology to clinical reality holds promising prospects for the hearing impaired.
Collapse
|
13
|
Smetak MR, Riojas KE, Sharma RK, Labadie RF. Beyond the phantom: Unroofing the scala vestibuli in a fresh temporal bone as a model for cochlear implant insertion experiments. J Neurosci Methods 2022; 382:109710. [PMID: 36207005 DOI: 10.1016/j.jneumeth.2022.109710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 09/06/2022] [Accepted: 09/13/2022] [Indexed: 11/07/2022]
Affiliation(s)
- Miriam R Smetak
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Ave S, Nashville, TN 37232, United States.
| | - Katherine E Riojas
- Department of Mechanical Engineering, Vanderbilt University, 2301 Vanderbilt Place PMB 401592, Nashville, TN 37240-1592, United States
| | - Rahul K Sharma
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Ave S, Nashville, TN 37232, United States
| | - Robert F Labadie
- Department of Otolaryngology - Head and Neck Surgery, Vanderbilt University Medical Center, 1215 21st Ave S, Nashville, TN 37232, United States; Department of Mechanical Engineering, Vanderbilt University, 2301 Vanderbilt Place PMB 401592, Nashville, TN 37240-1592, United States
| |
Collapse
|
14
|
Hrncirik F, Roberts IV, Swords C, Christopher PJ, Chhabu A, Gee AH, Bance ML. Impact of Scala Tympani Geometry on Insertion Forces during Implantation. BIOSENSORS 2022; 12:999. [PMID: 36354508 PMCID: PMC9688204 DOI: 10.3390/bios12110999] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 10/25/2022] [Accepted: 11/05/2022] [Indexed: 05/07/2023]
Abstract
(1) Background: During a cochlear implant insertion, the mechanical trauma can cause residual hearing loss in up to half of implantations. The forces on the cochlea during the insertion can lead to this mechanical trauma but can be highly variable between subjects which is thought to be due to differing anatomy, namely of the scala tympani. This study presents a systematic investigation of the influence of different geometrical parameters of the scala tympani on the cochlear implant insertion force. The influence of these parameters on the insertion forces were determined by testing the forces within 3D-printed, optically transparent models of the scala tympani with geometric alterations. (2) Methods: Three-dimensional segmentations of the cochlea were characterised using a custom MATLAB script which parametrised the scala tympani model, procedurally altered the key shape parameters (e.g., the volume, vertical trajectory, curvature, and cross-sectional area), and generated 3D printable models that were printed using a digital light processing 3D printer. The printed models were then attached to a custom insertion setup that measured the insertion forces on the cochlear implant and the scala tympani model during a controlled robotic insertion. (3) Results: It was determined that the insertion force is largely unaffected by the overall size, curvature, vertical trajectory, and cross-sectional area once the forces were normalised to an angular insertion depth. A Capstan-based model of the CI insertion forces was developed and matched well to the data acquired. (4) Conclusion: By using accurate 3D-printed models of the scala tympani with geometrical alterations, it was possible to demonstrate the insensitivity of the insertion forces to the size and shape of the scala tympani, after controlling for the angular insertion depth. This supports the Capstan model of the cochlear implant insertion force which predicts an exponential growth of the frictional force with an angular insertion depth. This concludes that the angular insertion depth, rather than the length of the CI inserted, should be the major consideration when evaluating the insertion force and associated mechanical trauma caused by cochlear implant insertion.
Collapse
Affiliation(s)
- Filip Hrncirik
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Iwan V. Roberts
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| | - Chloe Swords
- Cambridge Hearing Group, Cambridge, UK
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge CB2 3DY, UK
| | | | - Akil Chhabu
- Clinical School, University of Cambridge, Cambridge CB2 0SP, UK
| | - Andrew H. Gee
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge CB2 3DY, UK
| | - Manohar L. Bance
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK
| |
Collapse
|
15
|
Robotics, automation, active electrode arrays, and new devices for cochlear implantation: A contemporary review. Hear Res 2022; 414:108425. [PMID: 34979455 DOI: 10.1016/j.heares.2021.108425] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 12/16/2021] [Accepted: 12/23/2021] [Indexed: 01/14/2023]
Abstract
In the last two decades, cochlear implant surgery has evolved into a minimally invasive, hearing preservation surgical technique. The devices used during surgery have benefited from technological advances that have allowed modification and possible improvement of the surgical technique. Robotics has recently gained popularity in otology as an effective tool to overcome the surgeon's limitations such as tremor, drift and accurate force control feedback in laboratory testing. Cochlear implantation benefits from robotic assistance in several steps during the surgical procedure: (i) during the approach to the middle ear by automated mastoidectomy and posterior tympanotomy or through a tunnel from the postauricular skin to the middle ear (i.e. direct cochlear access); (ii) a minimally invasive cochleostomy by a robot-assisted drilling tool; (iii) alignment of the correct insertion axis on the basal cochlear turn; (iv) insertion of the electrode array with a motorized insertion tool. In recent years, the development of bone-attached parallel robots and image-guided surgical robotic systems has allowed the first successful cochlear implantation procedures in patients via a single hole drilled tunnel. Several other robotic systems, new materials, sensing technologies applied to the electrodes, and smart devices have been developed, tested in experimental models and finally some have been used in patients with the aim of reducing trauma in cochleostomy, and permitting slow and more accurate insertion of the electrodes. Despite the promising results in laboratory tests in terms of minimal invasiveness, reduced trauma and better hearing preservation, so far, no clinical benefits on residual hearing preservation or better speech performance have been demonstrated. Before these devices can become the standard approach for cochlear implantation, several points still need to be addressed, primarily cost and duration of the procedure. One can hope that improvement in the cost/benefit ratio will expand the technology to every cochlear implantation procedure. Laboratory research and clinical studies on patients should continue with the aim of making intracochlear implant insertion an atraumatic and reversible gesture for total preservation of the inner ear structure and physiology.
Collapse
|
16
|
Aebischer P, Mantokoudis G, Weder S, Anschuetz L, Caversaccio M, Wimmer W. In-Vitro Study of Speed and Alignment Angle in Cochlear Implant Electrode Array Insertions. IEEE Trans Biomed Eng 2021; 69:129-137. [PMID: 34110987 DOI: 10.1109/tbme.2021.3088232] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE The insertion of the electrode array is a critical step in cochlear implantation. Herein we comprehensively investigate the impact of the alignment angle and feed-forward speed on deep insertions in artificial scala tympani models with accurate macro-anatomy and controlled frictional properties. METHODS Motorized insertions (n=1033) were performed in six scala tympani models with varying speeds and alignment angles. We evaluated reaction forces and micrographs of the insertion process and developed a mathematical model to estimate the normal force distribution along the electrode arrays. RESULTS Insertions parallel to the cochlear base significantly reduce insertion energies and lead to smoother array movement. Non-constant insertion speeds allow to reduce insertion forces for a fixed total insertion time compared to a constant feed rate. CONCLUSION In cochlear implantation, smoothness and peak forces can be reduced with alignment angles parallel to the scala tympani centerline and with non-constant feed-forward speed profiles. SIGNIFICANCE Our results may help to provide clinical guidelines and improve surgical tools for manual and automated cochlear implantation.
Collapse
|