1
|
Nasri S, Samimi S, Eslami M, Hematpour K, Eslami M, Yarmohammadi H, Mollazadeh R, Rahmanian M. Efficacy and safety of mechanical transvenous lead extraction: median follow-up analysis and development of an experimental model for predicting survival post-extraction. Egypt Heart J 2025; 77:25. [PMID: 39998773 PMCID: PMC11861461 DOI: 10.1186/s43044-025-00617-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2024] [Accepted: 02/03/2025] [Indexed: 02/27/2025] Open
Abstract
BACKGROUND Cardiac implantable electronic device (CIED) implantation is on the rise, accompanied by an increase in its inevitable complications such as different types of CIED infections that require further therapy and potential device extraction. Ensuring efficacy and safety remains paramount in transvenous lead extraction (TLE), given the complex nature of the procedure. The purpose of this study is to assess the outcomes of relatively low-cost mechanical TLE, including mid-term clinical follow-up, and to develop a predictive model for post-TLE survival. This study included all consecutive patients admitted for TLE at two tertiary medical centers between 2016 and 2021. Baseline characteristics, TLE procedure details complications occurring during and/or after the procedure and follow-up outcomes were collected. RESULTS During the 5-year period, 100 consecutive patients underwent TLE. The mean age of the subjects was 61 ± 3 years. The average time from lead implantation to TLE was 69.34 ± 9.36 months, with a total of 216 leads extracted. The most common indication for TLE was infection observed in 87% of subjects with pocket infection seen in the majority (84%). Complete clinical success was achieved in 98% of patients, with major complications occurred in 5% of cases and only one case of peri-procedural death. Proposed experimental model showed that near 50% of the patients will live less than 73.29 months. CONCLUSION TLE demonstrated a high level of safety with low mortality and morbidity rates. Using low cost widely available mechanical tools is useful for treating CIED-related infections.
Collapse
Affiliation(s)
- Shima Nasri
- Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran
| | - Sahar Samimi
- McGovern Medical School, University of Texas, Houston, USA
| | - Masoud Eslami
- Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran
| | | | - Morteza Eslami
- Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran
| | - Hirad Yarmohammadi
- Columbia University Vagelos College of Physicians and Surgeons, New York, USA
| | - Reza Mollazadeh
- Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran.
| | - Mehrzad Rahmanian
- Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Islamic Republic of Iran, Tehran
| |
Collapse
|
2
|
Patel K, Toomu S, Lee E, Darden D, Jacobs K, Pollema T, Ho G, Birgersdotter-Green U. Computed tomography predictors of increased transvenous lead extraction difficulty. Pacing Clin Electrophysiol 2024; 47:1232-1240. [PMID: 38967391 DOI: 10.1111/pace.15034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 05/19/2024] [Accepted: 06/18/2024] [Indexed: 07/06/2024]
Abstract
BACKGROUND The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject. OBJECTIVE To identify CT characteristics associated with increased TLE difficulty. METHODS All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac-gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead-removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty. RESULTS A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell-in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead-removal fluoroscopy time (p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54-10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89-7.35), respectively. CONCLUSION In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead-associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.
Collapse
Affiliation(s)
- Kavisha Patel
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Sandeep Toomu
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Euyhyun Lee
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Douglas Darden
- Department of Cardiology, Kansas City Heart Rhythm Institute, Kansas City, Kansas, USA
| | - Kathleen Jacobs
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Travis Pollema
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | - Gordon Ho
- Department of Cardiology, University of California San Diego, La Jolla, California, USA
| | | |
Collapse
|
3
|
Migliore F, Pittorru R, De Lazzari M, Dall’Aglio PB, Cecchetto A, Previtero M, Pergola V, Thiene G, Masiero G, Tarantini G, Tarzia V, Gerosa G. Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction. Europace 2024; 26:euae191. [PMID: 38989913 PMCID: PMC11282457 DOI: 10.1093/europace/euae191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 07/03/2024] [Indexed: 07/12/2024] Open
Abstract
AIMS Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. METHODS AND RESULTS In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003-1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004-1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44-18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01-5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06-4.89; P = 0.035). CONCLUSION Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.
Collapse
Affiliation(s)
- Federico Migliore
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Raimondo Pittorru
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Manuel De Lazzari
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | | | - Antonella Cecchetto
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Marco Previtero
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Valeria Pergola
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Gaetano Thiene
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Giulia Masiero
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Giuseppe Tarantini
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Vincenzo Tarzia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | - Gino Gerosa
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| |
Collapse
|
4
|
Akhtar Z, Kontogiannis C, Georgiopoulos G, Starck CT, Leung LWM, Lee SY, Lee BK, Seshasai SRK, Sohal M, Gallagher MM. Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis. Europace 2023; 25:euad316. [PMID: 37882609 PMCID: PMC10638006 DOI: 10.1093/europace/euad316] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 08/07/2023] [Accepted: 09/24/2023] [Indexed: 10/27/2023] Open
Abstract
AIMS Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.
Collapse
Affiliation(s)
- Zaki Akhtar
- Department of Cardiology, St George’s University Hospital, London, UK
| | | | - Georgios Georgiopoulos
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Clinical Therapeutics, National and Kapodistrian University of Athens, Athens, Greece
| | - Christoph T Starck
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| | - Lisa W M Leung
- Department of Cardiology, St George’s University Hospital, London, UK
| | - Sun Y Lee
- Department of Medicine, San Joaquin General Hospital, French Camp, CA, USA
| | - Byron K Lee
- Division of Cardiology, University of California, San Francisco, CA, USA
| | | | - Manav Sohal
- Department of Cardiology, St George’s University Hospital, London, UK
| | - Mark M Gallagher
- Department of Cardiology, St George’s University Hospital, London, UK
| |
Collapse
|
5
|
Frei C, Hofer D, Jan S, Grebmer C, Breitenstein A. Single center experience with the novel rotating dilator sheath TightRail TM Sub-C in transvenous lead extraction. J Cardiovasc Electrophysiol 2023; 34:1738-1743. [PMID: 37343057 DOI: 10.1111/jce.15970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 05/06/2023] [Accepted: 06/05/2023] [Indexed: 06/23/2023]
Abstract
INTRODUCTION Transvenous lead extraction has become a frequent procedure in the context of device lead management and various tools are available. The aim of this study was to investigate the efficacy and safety of the novel short rotating dilator sheath TightRailTM Sub-C (Sub-C) in transvenous lead extraction. METHODS For this retrospective single-center analysis, we included consecutive patients undergoing transvenous lead extraction using the Sub-C from January 2018 until February 2020 at the University Heart Center Zurich. RESULTS A total of 87 leads were extracted within 45 patients using the Sub-C extraction sheath. The mean dwell time of the leads was 112 ± 9.1 months. Complete procedural success was achieved in 95.6% (43/45) and clinical procedural success in 97.8% (44/45). Two major complications (4.4%, 2/45) occurred, but neither was directly related to the Sub-C. CONCLUSION This retrospective single-center analysis suggests that transvenous lead extraction with a routine use of the TightRailTM Sub-C extraction sheath is a safe strategy resulting in high success rates that may offer useful theoretical benefits. Future studies are needed to evaluate the incremental benefit of a routine use of short extraction sheaths including the Sub-C during TLE procedures.
Collapse
Affiliation(s)
- Celine Frei
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| | - Daniel Hofer
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| | - Steffel Jan
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| | - Christian Grebmer
- Department of Cardiology, Cantonal Hospital Lucerne, Lucerne, Switzerland
| | - Alexander Breitenstein
- Electrophysiology, Department of Cardiology, University Hospital Zurich, University Heart Center, Zurich, Switzerland
| |
Collapse
|
6
|
Migliore F, Pittorru R, Dall'Aglio PB, De Lazzari M, Falzone PV, Sottini S, Dentico A, Ferrieri A, Pradegan N, Bertaglia E, Iliceto S, Gerosa G, Tarzia V, Carretta D. Outcomes of transvenous lead extraction in octogenarians using bidirectional rotational mechanical sheaths. Pacing Clin Electrophysiol 2023; 46:960-968. [PMID: 36951180 DOI: 10.1111/pace.14696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/01/2023] [Accepted: 03/07/2023] [Indexed: 03/24/2023]
Abstract
BACKGROUND Outcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid-term outcome after TLE. METHODS The study population comprised 83 patients (78.3% male; mean age 85 ± 3 years; [range 80-94 years]) with 181 target leads. All the leads (mean implant duration 112 ± 77 months [range 12-377]) were extracted exclusively using the Evolution RL sheaths (Cook Medical, Bloomington, IN, USA). RESULTS The main indication for TLE was infection in 84.3% of cases. Complete procedural success rate, clinical success rate, per lead were 93.9% and 98.3%, respectively. Failure of lead extraction was seen in 1.7% of leads. The additional use of a snare was required in 8.4% of patients. Major complications occurred in one patient (1.2%). Thirty-day mortality after TLE was 6%. During a mean time follow-up of 22 ± 21 months, 24 patients (29%) died. No procedure-related mortality occurred. Predictors of mortality included ischemic cardiomyopathy (HR 4.35; 95% CI 1.87-10.13; p = .001), left ventricularejection fraction ≤35% (HR 7.89; 95% CI 3.20-19.48; p < .001), and TLE for systemic infection (HR 4.24; 95% CI 1.69-10.66; p = .002). CONCLUSIONS At experienced centers bidirectional rotational mechanical sheaths combined with different mechanical tools and femoral approach allowreasonable success and safety in octogenarian with long lead dwell time. Patient's age should not influence the decision to extract or not the leads, although the 30-day and mid-term mortality are significant, especially in the present of specific comorbidities.
Collapse
Affiliation(s)
- Federico Migliore
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Raimondo Pittorru
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | | | - Manuel De Lazzari
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Pasquale Valerio Falzone
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Simone Sottini
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Alessia Dentico
- Division of Cardiovascular Diseases, Azienda Ospedaliera Universitaria, Ospedale Policlinico Consorziale, Bari, Italy
| | - Alessandra Ferrieri
- Division of Cardiovascular Diseases, Azienda Ospedaliera Universitaria, Ospedale Policlinico Consorziale, Bari, Italy
| | - Nicola Pradegan
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Emanuele Bertaglia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Sabino Iliceto
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Gino Gerosa
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Vincenzo Tarzia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Domenico Carretta
- Division of Cardiovascular Diseases, Azienda Ospedaliera Universitaria, Ospedale Policlinico Consorziale, Bari, Italy
| |
Collapse
|
7
|
Akhtar Z, Sohal M, Sheppard MN, Gallagher MM. Transvenous Lead Extraction: Work in Progress. Eur Cardiol 2023; 18:e44. [PMID: 37456768 PMCID: PMC10345938 DOI: 10.15420/ecr.2023.06] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 04/10/2023] [Indexed: 07/18/2023] Open
Abstract
Cardiac implantable electronic devices are the cornerstone of cardiac rhythm management, with a significant number of implantations annually. A rising prevalence of cardiac implantable electronic devices coupled with widening indications for device removal has fuelled a demand for transvenous lead extraction (TLE). With advancement of tools and techniques, the safety and efficacy profile of TLE has significantly improved since its inception. Despite these advances, TLE continues to carry risk of significant complications, including a superior vena cava injury and mortality. However, innovative approaches to lead extraction, including the use of the jugular and femoral accesses, offers potential for further gains in safety and efficacy. In this review, the indications and risks of TLE are discussed while examining the evolution of this procedure from simple traction to advanced methodologies, which have contributed to a significant improvement in safety and efficacy.
Collapse
Affiliation(s)
- Zaki Akhtar
- Department of Cardiology, St George's University Hospital NHS Foundation TrustLondon, UK
| | - Manav Sohal
- Department of Cardiology, St George's University Hospital NHS Foundation TrustLondon, UK
| | - Mary N Sheppard
- Cardiac Risk in the Young, Cardiovascular Pathology Unit, St George's University of LondonLondon, UK
| | - Mark M Gallagher
- Department of Cardiology, St George's University Hospital NHS Foundation TrustLondon, UK
| |
Collapse
|
8
|
Hofer D, Kuster N, Bebié MC, Sasse T, Steffel J, Breitenstein A. Success and Complication Rates of Transvenous Lead Extraction in a Developing High-Volume Extraction Center: The Zurich Experience. J Clin Med 2023; 12:jcm12062260. [PMID: 36983262 PMCID: PMC10051593 DOI: 10.3390/jcm12062260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 03/06/2023] [Accepted: 03/08/2023] [Indexed: 03/17/2023] Open
Abstract
Introduction: Transvenous lead extractions are increasingly performed for malfunction or infection of cardiac implantable electronic devices, but they harvest a potential for complications and suboptimal success. Apart from multicenter registries and reports from highly experienced single centers, the outcome in individual newly developing high-volume centers starting a lead extraction program is less well established. We aimed to evaluate the clinical and radiological success and complication rate at our center, having started a lead extraction program less than a decade ago. Methods: We retrospectively analyzed patients who underwent transvenous lead extraction at the University Hospital Zurich from 2013 to 2021 regarding success as well as complications and compared our results to previously reported outcome rates. Results: A total of 346 patients underwent 350 transvenous lead extractions from January 2013 to December 2021. Combined radiological success was achieved in 97.7% and clinical success in 96.0% of interventions. Procedure-related major complications occurred in 13 patients (3.7%). Death within 30 days after transvenous lead extractions occurred in 13 patients (3.7%), with a procedure-related mortality of 1.4% (five patients). Summary: Transvenous lead extractions in newly developing high-volume centers can be performed with high clinical and radiological success rates, but procedure-related major complications may affect a relevant number of patients. Compared to large single or multicenter registries of experienced centers, the success rate may be lower and the complication rate higher in centers newly starting with lead extraction, which may have important implications for patient selection, procedural planning, proctoring, and safety measures.
Collapse
|
9
|
Migliore F, Pittorru R, Dall'Aglio PB, De Lazzari M, Rovaris G, Piazzi E, Dentico A, Ferrieri A, D'Angelo G, Marzi A, Sawaf BE, Bertaglia E, Iliceto S, Gerosa G, Tarzia V, Carretta D, Mazzone P. Outcomes of transvenous lead extraction of very old leads using bidirectional rotational mechanical sheaths: Results of a multicentre study. J Cardiovasc Electrophysiol 2023; 34:728-737. [PMID: 36477909 DOI: 10.1111/jce.15767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 11/22/2022] [Accepted: 11/30/2022] [Indexed: 12/12/2022]
Abstract
INTRODUCTION Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.
Collapse
Affiliation(s)
- Federico Migliore
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Raimondo Pittorru
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Pietro Bernardo Dall'Aglio
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Manuel De Lazzari
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | | | - Elena Piazzi
- Department of Cardiology, San Gerardo Hospital, Monza, Italy
| | - Alessia Dentico
- Division of Cardiovascular Diseases, Azienda Ospedaliera Universitaria, Ospedale Policlinico Consorziale, Bari, Italy
| | - Alessandra Ferrieri
- Division of Cardiovascular Diseases, Azienda Ospedaliera Universitaria, Ospedale Policlinico Consorziale, Bari, Italy
| | - Giuseppe D'Angelo
- Departement of Cardiac Electrophysiology and Arrhythmology, San Raffaele Hospital, Milano, Italy
| | - Alessandra Marzi
- Departement of Cardiac Electrophysiology and Arrhythmology, San Raffaele Hospital, Milano, Italy
| | - Basma El Sawaf
- Departement of Cardiac Electrophysiology and Arrhythmology, San Raffaele Hospital, Milano, Italy
| | - Emanuele Bertaglia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Sabino Iliceto
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Gino Gerosa
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Vincenzo Tarzia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Domenico Carretta
- Division of Cardiovascular Diseases, Azienda Ospedaliera Universitaria, Ospedale Policlinico Consorziale, Bari, Italy
| | - Patrizio Mazzone
- Departement of Cardiac Electrophysiology and Arrhythmology, San Raffaele Hospital, Milano, Italy
| |
Collapse
|
10
|
Zsigmond EJ, Saghy L, Benak A, Miklos M, Makai A, Hegedus Z, Alacs E, Agocs S, Vamos M. A head-to-head comparison of laser vs. powered mechanical sheaths as first choice and second line extraction tools. Europace 2022; 25:591-599. [PMID: 36352816 PMCID: PMC9935030 DOI: 10.1093/europace/euac200] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 10/05/2022] [Indexed: 11/11/2022] Open
Abstract
AIMS During transvenous lead extraction (TLE) longer dwelling time often requires the use of powered sheaths. This study aimed to compare outcomes with the laser and powered mechanical tools. METHODS AND RESULTS Single-centre data from consecutive patients undergoing TLE between 2012 and 2021 were retrospectively analysed. Efficacy and safety of the primary extraction tool were compared. Procedures requiring crossover between powered sheaths were also analysed. Moreover, we examined the efficacy of each level of the stepwise approach. Out of 166 patients, 142 (age 65.4 ± 13.7 years) underwent TLE requiring advanced techniques with 245 leads (dwelling time 9.4 ± 6.3 years). Laser sheaths were used in 64.9%, powered mechanical sheaths in 35.1% of the procedures as primary extraction tools. Procedural success rate was 85.5% with laser and 82.5% with mechanical sheaths (P = 0.552). Minor and major complications were observed in similar rate. Procedural mortality occurred only in the laser group in the case of three patients. Crossover was needed in 19.5% after laser and in 12.8% after mechanical extractions (P = 0.187). Among crossover procedures, only clinical success favoured the secondary mechanical arm (87.1 vs. 54.5%, aOR: 0.09, 95% CI: 0.01-0.79, P = 0.030). After step-by-step efficacy analysis, procedural success was 64.9% with the first-line extraction tool, 75.1% after crossover, 84.5% with bailout femoral snare, and 91.8% by non-emergency surgery. CONCLUSION The efficacy and safety of laser and mechanical sheaths were similar, however in the subgroup of crossover procedures mechanical tools had better performance regarding clinical success. Device diversity seems to help improving outcomes, especially in the most complicated cases.
Collapse
Affiliation(s)
- Elod-Janos Zsigmond
- Cardiac Electrophysiology Division, Department of Internal Medicine, University of Szeged, Semmelweis str. 8, 6725 Szeged, Hungary
| | - Laszlo Saghy
- Cardiac Electrophysiology Division, Department of Internal Medicine, University of Szeged, Semmelweis str. 8, 6725 Szeged, Hungary
| | - Attila Benak
- Cardiac Electrophysiology Division, Department of Internal Medicine, University of Szeged, Semmelweis str. 8, 6725 Szeged, Hungary
| | - Marton Miklos
- Cardiac Electrophysiology Division, Department of Internal Medicine, University of Szeged, Semmelweis str. 8, 6725 Szeged, Hungary
| | - Attila Makai
- Cardiac Electrophysiology Division, Department of Internal Medicine, University of Szeged, Semmelweis str. 8, 6725 Szeged, Hungary
| | - Zoltan Hegedus
- Heart Surgery Department, University of Szeged, Semmelweis str. 8, 6725 Szeged, Hungary
| | - Endre Alacs
- Department of Anaesthesiology and Intensive Therapy, University of Szeged, Semmelweis str. 6, 6725 Szeged, Hungary
| | - Szilvia Agocs
- Department of Anaesthesiology and Intensive Therapy, University of Szeged, Semmelweis str. 6, 6725 Szeged, Hungary
| | - Mate Vamos
- Corresponding author. Tel: +36 62 341 559; Fax: +36 62 342 538, E-mails address: ;
| |
Collapse
|
11
|
Muhlestein JB, Dranow E, Chaney J, Navaravong L, Steinberg BA, Freedman RA. Successful avoidance of superior vena cava injury during transvenous lead extraction using a tandem femoral-superior approach. Heart Rhythm 2022; 19:1104-1108. [PMID: 35245690 PMCID: PMC9250613 DOI: 10.1016/j.hrthm.2022.02.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 02/23/2022] [Accepted: 02/23/2022] [Indexed: 11/26/2022]
Abstract
BACKGROUND Transvenous pacemaker and defibrillator lead extraction is a higher risk procedure with variation in preferred technique. A frequently fatal complication of this procedure is perforation of the superior vena cava. We have developed a tandem femoral-superior technique that incorporates snaring of targeted leads from a femoral approach combined with use of a rotational cutting sheath advanced over the lead from the subclavian vein. OBJECTIVE We sought to evaluate the safety and efficacy of a tandem femoral-superior approach to lead extraction. METHODS Consecutive patients undergoing transvenous extraction of at least 1 pacemaker or defibrillator lead with implant duration ≥1 year in which a tandem femoral-superior technique was used as the initial extraction strategy were included. The registry spanned 2010-2018 and consisted of procedures performed by a single primary operator. RESULTS A total of 131 patients were included. A total of 267 leads with a mean implant duration of 9.8 years, including 90 defibrillator leads (33.7%), were targeted for extraction. No superior vena cava perforation or other vascular damage occurred. Clinical procedural success was achieved in 96.2% of cases. There were 5 major complications (3.8% of patients), with 3 being pericardial effusion requiring intervention. There were no deaths. CONCLUSION A tandem femoral-superior approach to lead extraction effectively eliminated superior vena cava injury. This is a safe and effective technique for transvenous lead extraction.
Collapse
Affiliation(s)
| | - Elizabeth Dranow
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah
| | - Jason Chaney
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah
| | | | | | - Roger A Freedman
- Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
12
|
Tabata H, Okada A, Kobayashi H, Shoin W, Okano T, Higuchi S, Yagishita D, Ebisawa S, Motoki H, Shoda M, Kuwahara K. Usefulness of the controlled-rotation dilator sheath "Evolution RL" for extraction of old leads in two Japanese centers - An experience in use. J Cardiol 2022; 80:339-343. [PMID: 35701313 DOI: 10.1016/j.jjcc.2022.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Revised: 04/29/2022] [Accepted: 05/15/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND Transvenous lead extraction (TLE) is an established procedure for the management of cardiovascular implantable electronic devices. However, some difficulties and risks of complications still exist, especially in old and adhered leads. Evolution RL (Cook Medical, Bloomington, IN, USA) is a newly introduced device for TLE; however, no clinical results have been reported in Japan, and the results with older leads are unknown. We investigated the efficacy and safety of Evolution RL and its usefulness for old leads at two TLE centers in Japan. METHODS A total of 27 consecutive patients who underwent lead extraction using Evolution RL at Shinshu University Hospital and Tokyo Women's Medical University Hospital from September 2017 to December 2019 were retrospectively enrolled. We examined the backgrounds of the patients and leads and investigated the efficacy and safety of the procedures. We divided the leads into two groups according to the number of years of implantation (10 years) and compared the results. RESULTS Among the 27 patients, 20 (74.1%) were men, and the median age was 62 (14-91) years. The total number of leads was 58, and the median implantation duration was 136 months (8-448). We achieved clinical success in all patients and complete procedural success in 24 patients (88.9%). In three patients, the broken tip of the lead remained in the heart. No major complications were noted. Of the 58 leads, there were 34 leads with more than 10 years of implantation, with significantly more Evolution RLs used (94.1% vs. 54.2%, p = 0.001) and significantly higher percentages of Evolution 11Fr, 13Fr, and steady sheaths used (79.4% vs. 33.3%, p = 0.001, 52.9% vs. 16.7%, p = 0.006, and 64.7% vs. 20.8%, p = 0.001, respectively). CONCLUSIONS In two TLE centers in Japan, Evolution RL was shown to be safe and effective, even in leads older than 10 years.
Collapse
Affiliation(s)
- Hiroaki Tabata
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Ayako Okada
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan.
| | - Hideki Kobayashi
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Wataru Shoin
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Takahiro Okano
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Satoshi Higuchi
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Daigo Yagishita
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Soichiro Ebisawa
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Hirohiko Motoki
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| | - Morio Shoda
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan; Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Koichiro Kuwahara
- Department of Cardiovascular Medicine, Shinshu University School of Medicine, Nagano, Japan
| |
Collapse
|
13
|
Soontornmanokati N, Sirikhamkorn C, Methachittiphan N, Chintanavilas K, Apakuppakul S, Ngarmukos T, Apiyasawat S, Lohawijarn W, Chandanamattha P. Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand. Indian Pacing Electrophysiol J 2022; 22:123-128. [PMID: 35219811 PMCID: PMC9091722 DOI: 10.1016/j.ipej.2022.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 01/27/2022] [Accepted: 02/18/2022] [Indexed: 11/24/2022] Open
Abstract
Background Transvenous Lead Extraction (TLE) is a standard treatment for some late Cardiac Implantable Electronics Device (CIED) complications. The outcome of transvenous lead extraction procedure in Thailand is not robust. Methods A Single-center retrospective cohort of TLE procedures performed at Ramathibodi hospital between January 2008 and December 2020 was studied. Results There were 157 leads from 105 patients who underwent lead removal procedure during the specified period. Data analysis was performed from 79 TLE patients due to incomplete data and lead explant procedure of the excluded subjects. Mean patients’ age was 57.7 ± 18.7 years, with 70.9% male. There were 82 pacemaker leads, 35 ICD leads, and 5 CS leads (mean number of leads were 1.54 ± 0.66 per patient), with mean implanted duration of 87.8 ± 68.2 months. Main indication for TLE was infection-related, which accounted for 67.1% of the cases. Overall clinical success rate was 97.5%. Mean operative time was 163.8 ± 69.5 min. Major complications occurred in 4 patients (5.1%) with one in-hospital mortality from severe sepsis. Conclusion TLE using laser sheath and rotating mechanical sheath for transvenous lead extraction is effective and safe, even outside high-volume center.
Collapse
Affiliation(s)
- Natcha Soontornmanokati
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Chulaporn Sirikhamkorn
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Nilubon Methachittiphan
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Kumpol Chintanavilas
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Sanatcha Apakuppakul
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Tachapong Ngarmukos
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Sirin Apiyasawat
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Wachara Lohawijarn
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| | - Pakorn Chandanamattha
- Cardiology Unit, Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
| |
Collapse
|
14
|
Levesque P, Plourde B, Jacques F, Charbonneau É, Audet MÈ, Poulin JF, Philippon F. Left common carotid artery to left innominate vein arteriovenous fistula after transvenous laser lead extraction. Pacing Clin Electrophysiol 2022; 45:696-699. [PMID: 34979041 DOI: 10.1111/pace.14439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 11/07/2021] [Accepted: 12/05/2021] [Indexed: 11/27/2022]
Abstract
Transvenous lead extraction (TLE) is used for lead infection, lead debulking, venous recanalization and device upgrades. Lead extraction is performed using specialized tools including locking stylets, mechanical or rotating sheaths, femoral snares or laser sheaths. The most feared complications associated with lead extraction are bleeding, vascular tear, cardiac avulsion and tamponade. Despite technological progress, the incidence of major procedural complications including death remains slightly above 1%. This case depicts an asymptomatic left common carotid artery (LCCA) to left innominate vein arteriovenous fistula (AVF) after laser-assisted TLE successfully treated with an endovascular covered stent.
Collapse
Affiliation(s)
- Patrick Levesque
- Electrophysiology Division, Institut Universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Benoît Plourde
- Electrophysiology Division, Institut Universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Frédéric Jacques
- Cardiac Surgery Division, Institut Universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Éric Charbonneau
- Cardiac Surgery Division, Institut Universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - Marie-Ève Audet
- Radiology Division, Centre Hospitalier Universitaire de Québec, Québec, Canada
| | | | - François Philippon
- Electrophysiology Division, Institut Universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| |
Collapse
|
15
|
Gallagher MM, Akhtar Z, Starck CT. Preventing fatal injury to the Superior Vena Cava. Ann Thorac Surg 2021; 114:1523-1524. [PMID: 34793763 DOI: 10.1016/j.athoracsur.2021.10.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 10/02/2021] [Indexed: 11/01/2022]
|
16
|
Migliore F, Tarzia V, Dall'Aglio PB, Falzone PV, De Lazzari M, Bottio T, D'Onofrio A, Padalino M, Vida V, Rosso J, Leoni L, Pittarello D, Bertaglia E, Iliceto S, Gerosa G. The valuable interaction among cardiac surgeon and electrophysiologist for transvenous rotational mechanical lead extraction. Pacing Clin Electrophysiol 2021; 45:92-102. [PMID: 34699079 DOI: 10.1111/pace.14396] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 09/23/2021] [Accepted: 10/24/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND Recent studies have shown that Evolution RL bidirectional rotational mechanical sheath (Cook Medical,USA) is an effective and safe technique for transvenous lead extraction (TLE). We reported our experience with the bidirectional rotational mechanical tools using a multidisciplinary approach highlighting the value of a joint cardiac surgeon and electrophysiologist collaboration. METHODS The study population comprised 84 patients (77%male;mean age 65±18 years) undergoing TLE.After multidisciplinary evaluation, a combined procedure was considered. RESULTS The main indication for TLE was infection in 54 cases (64%).Overall,152 leads were extracted with a mean implant duration of 94±63 months (range 12-421).Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 91.6 % (77/84),97.6% (82/84), and 98.6%(150/152), respectively.Eighteen combined procedure were performed in 12 patients (14%), such as "hybrid approach" (n = 2) or TLE concomitant to:1) transcatheter aspiration procedure for large vegetation (n = 8); 2) left ventricular assistance device implantation as bridge to cardiac transplantation (n = 1); 3) permanent pacing with epicardial leads (n = 6); 4) tricuspid valve replacement (n = 1).One major complication (1.2%) and 11 (13%) minor complications were encountered.No injury to the superior vena cava occurred and no procedure-related deaths were reported. During a mean time follow-up of 21±18 months, 17 patients (20%) died.They were more often diabetics (P = 0.02), and they underwent TLE more often for infection (P = 0.004). CONCLUSIONS Our results support the finding that excellent outcomes can be achieved in performing TLE of chronically implanted leads by using the Evolution RL bidirectional rotational mechanical sheath and a multidisciplinary team approach involving both electrophysiologist and cardiac surgeon as first line operators. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Federico Migliore
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Vincenzo Tarzia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | | | - Pasquale Valerio Falzone
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Manuel De Lazzari
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Tomaso Bottio
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Augusto D'Onofrio
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Massimo Padalino
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Vladimiro Vida
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Jacopo Rosso
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Loira Leoni
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Demetrio Pittarello
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Emanuele Bertaglia
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Sabino Iliceto
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| | - Gino Gerosa
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Italy
| |
Collapse
|
17
|
Shah K, Pollema T, Birgersdotter-Green U. Performance and outcomes of transvenous rotational lead extraction: Results from a prospective, monitored, global clinical study-"An evolution in extraction". Heart Rhythm O2 2021; 2:122-123. [PMID: 34115052 PMCID: PMC8183959 DOI: 10.1016/j.hroo.2021.03.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Affiliation(s)
- Kunal Shah
- Division of Cardiology, Cardiac Electrophysiology Program, Sulpizio Family Cardiovascular Center, La Jolla, California, and the University of California Medical Center, San Diego, California
| | - Travis Pollema
- Division of Cardiothoracic surgery, Sulpizio Family Cardiovascular Center, La Jolla, California, and the University of California Medical Center, San Diego, California
| | - Ulrika Birgersdotter-Green
- Division of Cardiology, Cardiac Electrophysiology Program, Sulpizio Family Cardiovascular Center, La Jolla, California, and the University of California Medical Center, San Diego, California
| |
Collapse
|