1
|
Green PG, Monteiro C, Holdsworth DA, Betts TR, Herring N. Cardiac resynchronization using fusion pacing during exercise. J Cardiovasc Electrophysiol 2024; 35:146-154. [PMID: 37888415 DOI: 10.1111/jce.16120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/02/2023] [Accepted: 10/24/2023] [Indexed: 10/28/2023]
Abstract
INTRODUCTION Fusion pacing requires correct timing of left ventricular pacing to right ventricular activation, although it is unclear whether this is maintained when atrioventricular (AV) conduction changes during exercise. We used cardiopulmonary exercise testing (CPET) to compare cardiac resynchronization therapy (CRT) using fusion pacing or fixed AV delays (AVD). METHODS Patients 6 months post-CRT implant with PR intervals < 250 ms performed two CPET tests, using either the SyncAV™ algorithm or fixed AVD of 120 ms in a double-blinded, randomized, crossover study. All other programming was optimized to produce the narrowest QRS duration (QRSd) possible. RESULTS Twenty patients (11 male, age 71 [65-77] years) were recruited. Fixed AVD and fusion programming resulted in similar narrowing of QRSd from intrinsic rhythm at rest (p = .85). Overall, there was no difference in peak oxygen consumption (V̇O2 PEAK , p = .19), oxygen consumption at anaerobic threshold (VT1, p = .42), or in the time to reach either V̇O2 PEAK (p = .81) or VT1 (p = .39). The BORG rating of perceived exertion was similar between groups. CPET performance was also analyzed comparing whichever programming gave the narrowest QRSd at rest (119 [96-136] vs. 134 [119-142] ms, p < .01). QRSd during exercise (p = .03), peak O2 pulse (mL/beat, a surrogate of stroke volume, p = .03), and cardiac efficiency (watts/mL/kg/min, p = .04) were significantly improved. CONCLUSION Fusion pacing is maintained during exercise without impairing exercise capacity compared with fixed AVD. However, using whichever algorithm gives the narrowest QRSd at rest is associated with a narrower QRSd during exercise, higher peak stroke volume, and improved cardiac efficiency.
Collapse
Affiliation(s)
- Peregrine G Green
- Department of Physiology, Anatomy and Genetics, Burdon Sanderson Cardiac Science Centre, University of Oxford, Oxford, UK
- Department of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Oxford Heart Centre, John Radcliffe Hospital, University of Oxford NHS Foundation Trust, Oxford, UK
| | - Cristiana Monteiro
- Department of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - David A Holdsworth
- Department of Physiology, Anatomy and Genetics, Burdon Sanderson Cardiac Science Centre, University of Oxford, Oxford, UK
- Oxford Heart Centre, John Radcliffe Hospital, University of Oxford NHS Foundation Trust, Oxford, UK
| | - Timothy R Betts
- Department of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Oxford Heart Centre, John Radcliffe Hospital, University of Oxford NHS Foundation Trust, Oxford, UK
| | - Neil Herring
- Department of Physiology, Anatomy and Genetics, Burdon Sanderson Cardiac Science Centre, University of Oxford, Oxford, UK
- Oxford Heart Centre, John Radcliffe Hospital, University of Oxford NHS Foundation Trust, Oxford, UK
| |
Collapse
|
2
|
Coluccia G, Dell'Era G, Ghiglieno C, De Vecchi F, Spinoni E, Santagostino M, Guido A, Zaccaria M, Patti G, Accogli M, Palmisano P. Optimization of the atrioventricular delay in conduction system pacing. J Cardiovasc Electrophysiol 2023; 34:1441-1451. [PMID: 37161936 DOI: 10.1111/jce.15927] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 04/16/2023] [Accepted: 05/01/2023] [Indexed: 05/11/2023]
Abstract
INTRODUCTION In patients receiving conduction system pacing (CSP), it is not well established how to program the sensed atrioventricular delay (sAVD), with respect to the type of capture obtained (selective, nonselective His-bundle [HB] capture or left bundle branch [LBB] capture). The aim of this study was to acutely assess the effectiveness of an electrophysiology (EP)-guided method for sAVD optimization by comparing it with the echocardiogram-guided optimization. METHODS AND RESULTS Consecutive patients undergoing HB or LBB pacing were enrolled. The EP-guided sAVD was defined as the sAVD leading to a PR interval of 150 ms on surface electrocardiogram (ECG). In HB pacing patients, EP-guided sAVD was obtained subtracting the time from the onset of the P wave on ECG to the local atrial electrogram (EGM) recorded by the atrial lead (right atrial sensing latency, RASL) and the His-ventricular interval from 150 ms; in LBB pacing patients, subtracting RASL from 150 ms. Transmitral flow assessment by pulsed wave Doppler was used to find the echo-optimized sAVD by a modified iterative method. The discordance between the EP-guided and the echo-optimized sAVD was recorded. RESULTS Seventy-one patients were enrolled: 12 with selective, 32 nonselective HB capture, and 27 LBB capture. Overall, the rate of concordance between the EP-guided and the echo-optimized sAVD was 71.8%, with no significant differences between the three groups. CONCLUSION In CSP patients, an optimal sAVD can be programmed, in more than 70% of cases, considering only simple EGM intervals to obtain a physiological PR interval on surface ECG.
Collapse
Affiliation(s)
| | - Gabriele Dell'Era
- Division of Cardiology, Maggiore della Carità Hospital, University of Eastern Piedmont, Novara, Italy
| | - Chiara Ghiglieno
- Division of Cardiology, Maggiore della Carità Hospital, University of Eastern Piedmont, Novara, Italy
| | - Federica De Vecchi
- Division of Cardiology, Maggiore della Carità Hospital, University of Eastern Piedmont, Novara, Italy
| | - Enrico Spinoni
- Division of Cardiology, Maggiore della Carità Hospital, University of Eastern Piedmont, Novara, Italy
| | - Matteo Santagostino
- Division of Cardiology, Maggiore della Carità Hospital, University of Eastern Piedmont, Novara, Italy
| | | | - Maria Zaccaria
- Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy
| | - Giuseppe Patti
- Division of Cardiology, Maggiore della Carità Hospital, University of Eastern Piedmont, Novara, Italy
| | | | | |
Collapse
|
3
|
Atwater BD, Emerek K, Loring Z, Polcwiartek C, Jackson KP, Friedman DJ. Frequency and causes of QRS prolongation during exercise electrocardiogram testing in biventricular paced patients with heart failure. HeartRhythm Case Rep 2020; 6:308-312. [PMID: 32577383 PMCID: PMC7300328 DOI: 10.1016/j.hrcr.2020.02.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Affiliation(s)
- Brett D Atwater
- Division of Cardiology, Duke University Medical Center, Durham, North Carolina
| | - Kasper Emerek
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Zak Loring
- Division of Cardiology, Duke University Medical Center, Durham, North Carolina
| | - Christoffer Polcwiartek
- Division of Cardiology, Duke University Medical Center, Durham, North Carolina.,Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Kevin P Jackson
- Division of Cardiology, Duke University Medical Center, Durham, North Carolina
| | - Daniel J Friedman
- Division of Cardiology, Yale University Medical Center, New Haven, Connecticut
| |
Collapse
|
4
|
Niu H, Yu Y, Sturdivant JL, An Q, Gold MR. The effect of posture, exercise, and atrial pacing on atrioventricular conduction in systolic heart failure. J Cardiovasc Electrophysiol 2019; 30:2892-2899. [PMID: 31691436 DOI: 10.1111/jce.14264] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 08/29/2019] [Accepted: 11/01/2019] [Indexed: 11/28/2022]
Abstract
BACKGROUND Optimization of atrioventricular (AV) intervals for cardiac resynchronization therapy (CRT) programming is typically performed in supine patients at rest, which may not reflect AV timing in other conditions. OBJECTIVE To evaluate the effects of posture, exercise, and atrial pacing on intrinsic AV intervals in patients with CRT devices. METHODS Rate-dependent A-V delay by exercise was a multicenter, prospective trial of patients in sinus rhythm following CRT implantation. Intracardiac electrograms were recorded to analyze atrial to right ventricular (ARV), atrial to left ventricular (ALV), and RV to LV (VV) time intervals. Heart rate was increased with incremental atrial pacing in different postures, followed by an exercise treadmill test. RESULTS This study included 36 patients. At rest, AV intervals changed minimally with posture. With atrial pacing, AV interval immediately increased compared with sinus rhythm, with ARV slopes being 8.1 ± 7.7, 8.8 ± 13.4, and 6.8 ± 6.5 milliseconds per beat per minute (ms/bpm) and ALV slopes being 8.2 ± 7.7, 9.1 ± 12.8, and 7.0 ± 6.5 ms/bpm for supine, standing and sitting positions, respectively. As the paced heart rate increased, ARV and ALV intervals increased more gradually with similar trends. Interventricular conduction times changed less than 0.2 ms/bpm with atrial pacing. During exercise, the direction of change of intrinsic ARV intervals, as heart rate increased, was variable between patients with relatively small overall group changes (0.1 ± 1.4 and 0.2 ± 1.2 ms/bpm for ARV and ALV, respectively). CONCLUSION Posture and exercise have a smaller effect on AV timing compared with atrial pacing. However, individualized optimization and dynamic rate related changes may be needed to maintain optimal fusion with left ventricular (LV) stimulation.
Collapse
Affiliation(s)
- Hongxia Niu
- State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.,Division of Cardiology, Medical University of South Carolina, Charleston, South Carolina
| | - Yinghong Yu
- Division of Cardiology, Medical University of South Carolina, St. Paul, Minnesota
| | - John L Sturdivant
- Division of Cardiology, Medical University of South Carolina, Charleston, South Carolina
| | - Qi An
- Division of Cardiology, Medical University of South Carolina, St. Paul, Minnesota
| | - Michael R Gold
- Division of Cardiology, Medical University of South Carolina, Charleston, South Carolina
| |
Collapse
|
5
|
Rowe MK, Kaye GC. Advances in atrioventricular and interventricular optimization of cardiac resynchronization therapy - what's the gold standard? Expert Rev Cardiovasc Ther 2018; 16:183-196. [PMID: 29338475 DOI: 10.1080/14779072.2018.1427582] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
INTRODUCTION Cardiac resynchronization therapy (CRT) is one of the most important advances in heart failure management in the last twenty years. Approximately one-third of patients appear not to respond to therapy. Although there are a number of possible mechanisms for non-response, an important factor is suboptimal atrioventricular (AV) and interventricular (VV) timing intervals. There remains controversy over whether routinely optimizing intervals is necessary and there is no agreed gold standard methodology. Optimization has classically been performed using echocardiography which has limits related to resource use, time-cost and variable reproducibility. Newer optimization methods using device-based sensors and algorithms show promise in reducing heart-failure hospitalization compared with echocardiography. Areas covered: This review outlines the rationale for optimization, the principles of AV and VV optimization, the standard echocardiographic approach and newer device-based algorithms and the evidence base for their use. Expert commentary: The incremental gains of optimization are likely to be real, but small, compared to the overall improvement gained from cardiac resynchronization itself. At this time routine optimization may not be mandatory but should be performed where there is no response to CRT. Device-based optimization algorithms appear to be practical and in some cases, deliver superior clinical outcomes compared to echocardiography.
Collapse
Affiliation(s)
- Matthew K Rowe
- a Department of Cardiology , Princess Alexandra Hospital , Brisbane , Australia.,b Faculty of Medicine , The University of Queensland , Brisbane , Australia
| | - Gerald C Kaye
- a Department of Cardiology , Princess Alexandra Hospital , Brisbane , Australia.,b Faculty of Medicine , The University of Queensland , Brisbane , Australia
| |
Collapse
|
6
|
Houmsse M, Abraham WT. Continuously adjusting CRT therapy: clinical impact of adaptive cardiac resynchronization therapy. Expert Rev Cardiovasc Ther 2014; 12:541-8. [DOI: 10.1586/14779072.2014.901150] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
7
|
Nayar V, Khan FZ, Pugh PJ. Optimizing atrioventricular and interventricular intervals following cardiac resynchronization therapy. Expert Rev Cardiovasc Ther 2014; 9:185-97. [DOI: 10.1586/erc.10.187] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
8
|
Molenaar MMD, Oude Velthuis B, Scholten MF, Stevenhagen JY, Wesselink WA, van Opstal JM. Optimisation of cardiac resynchronization therapy in clinical practice during exercise. Neth Heart J 2013; 21:458-63. [PMID: 23821492 PMCID: PMC3776071 DOI: 10.1007/s12471-013-0438-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Aims Although cardiac resynchronisation therapy (CRT) is an established treatment to improve cardiac function, a significant amount of patients do not experience noticeable improvement in their cardiac function. Optimal timing of the delay between atrial and ventricular pacing pulses (AV delay) is of major importance for effective CRT treatment and this optimum may differ between resting and exercise conditions. In this study the feasibility of haemodynamic measurements by the non-invasive finger plethysmographic method (Nexfin) was used to optimise the AV delay during exercise. Methods and results Thirty-one patients implanted with a CRT device in the last 4 years participated in the study. During rest and in exercise, stroke volume (SV) was measured using the Nexfin device for several AV delays. The optimal AV delay at rest and in exercise was determined using the least squares estimates (LSE) method. Optimisation created a clinically significant improvement in SV of 10 %. The relation between HR and the optimal AV delay was patient dependent. Conclusion A potential increase in SV of 10 % can be achieved using Nexfin for optimisation of AV delay during exercise. A considerable number of patients showed benefit with lengthening of the AV delay during exercise.
Collapse
Affiliation(s)
- M M D Molenaar
- Thoraxcentrum Twente, Medisch Spectrum Twente, Haaksbergerstraat 55, 7513 ER, Enschede, the Netherlands,
| | | | | | | | | | | |
Collapse
|
9
|
Shanmugam N, Prada-Delgado O, Campos AG, Grimster A, Valencia O, Baltabaeva A, Jones S, Anderson L. Rate-adaptive AV delay and exercise performance following cardiac resynchronization therapy. Heart Rhythm 2012; 9:1815-21. [PMID: 22772135 DOI: 10.1016/j.hrthm.2012.07.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2012] [Indexed: 11/30/2022]
Affiliation(s)
- Nesan Shanmugam
- Department of Cardiology, St George's Healthcare NHS Trust, London, United Kingdom.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
AV interval optimization using pressure volume loops in dual chamber pacemaker patients with maintained systolic left ventricular function. Clin Res Cardiol 2012; 101:647-53. [DOI: 10.1007/s00392-012-0439-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 02/28/2012] [Indexed: 11/27/2022]
|
11
|
Rafie R, Qamruddin S, Ozhand A, Taha N, Naqvi TZ. Shortening of atrioventricular delay at increased atrial paced heart rates improves diastolic filling and functional class in patients with biventricular pacing. Cardiovasc Ultrasound 2012; 10:2. [PMID: 22269022 PMCID: PMC3292936 DOI: 10.1186/1476-7120-10-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2011] [Accepted: 01/24/2012] [Indexed: 11/22/2022] Open
Abstract
Background Use of rate adaptive atrioventricular (AV) delay remains controversial in patients with biventricular (Biv) pacing. We hypothesized that a shortened AV delay would provide optimal diastolic filling by allowing separation of early and late diastolic filling at increased heart rate (HR) in these patients. Methods 34 patients (75 ± 11 yrs, 24 M, LVEF 34 ± 12%) with Biv and atrial pacing had optimal AV delay determined at baseline HR by Doppler echocardiography. Atrial pacing rate was then increased in 10 bpm increments to a maximum of 90 bpm. At each atrial pacing HR, optimal AV delay was determined by changing AV delay until best E and A wave separation was seen on mitral inflow pulsed wave (PW) Doppler (defined as increased atrial duration from baseline or prior pacemaker setting with minimal atrial truncation). Left ventricular (LV) systolic ejection time and velocity time integral (VTI) at fixed and optimal AV delay was also tested in 13 patients. Rate adaptive AV delay was then programmed according to the optimal AV delay at the highest HR tested and patients were followed for 1 month to assess change in NYHA class and Quality of Life Score as assessed by Minnesota Living with Heart Failure Questionnaire. Results 81 AV delays were evaluated at different atrial pacing rates. Optimal AV delay decreased as atrial paced HR increased (201 ms at 60 bpm, 187 ms at 70 bpm, 146 ms at 80 bpm and 123 ms at 90 bpm (ANOVA F-statistic = 15, p = 0.0010). Diastolic filling time (P < 0.001 vs. fixed AV delay), mitral inflow VTI (p < 0.05 vs fixed AV delay) and systolic ejection time (p < 0.02 vs. fixed AV delay) improved by 14%, 5% and 4% respectively at optimal versus fixed AV delay at the same HR. NYHA improved from 2.6 ± 0.7 at baseline to 1.7 ± 0.8 (p < 0.01) 1 month post optimization. Physical component of Quality of Life Score improved from 32 ± 17 at baseline to 25 ± 12 (p < 0.05) at follow up. Conclusions Increased heart rate by atrial pacing in patients with Biv pacing causes compromise in diastolic filling time which can be improved by AV delay shortening. Aggressive AV delay shortening was required at heart rates in physiologic range to achieve optimal diastolic filling and was associated with an increase in LV ejection time during optimization. Functional class improved at 1 month post optimization using aggressive AV delay shortening algorithm derived from echo-guidance at the time of Biv pacemaker optimization.
Collapse
Affiliation(s)
- Reza Rafie
- Echocardiographic Laboratories, Department of Medicine, Keck School of Medicine, University of Southern California, Los Angeles, California 90033, USA
| | | | | | | | | |
Collapse
|
12
|
Suzuki T, Osaka T, Kuroda Y, Hasebe H, Yokoyama E, Kamiya K, Kodama I. Potential Benefit of Bachmann’s Bundle Pacing on Left Ventricular Performance in Patients With Cardiac Resynchronized Therapy. Circ J 2012; 76:2799-806. [DOI: 10.1253/circj.cj-12-0811] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Tomoyuki Suzuki
- Division of Arrhythmia and Electrophysiology, Shizuoka Saiseikai General Hospital
- Department of Cardiovascular Research, Research Institute of Environmental Medicine, Nagoya University
| | - Toshiyuki Osaka
- Division of Arrhythmia and Electrophysiology, Shizuoka Saiseikai General Hospital
| | - Yusuke Kuroda
- Division of Arrhythmia and Electrophysiology, Shizuoka Saiseikai General Hospital
| | - Hideyuki Hasebe
- Division of Arrhythmia and Electrophysiology, Shizuoka Saiseikai General Hospital
| | - Eriko Yokoyama
- Division of Arrhythmia and Electrophysiology, Shizuoka Saiseikai General Hospital
| | - Kaichiro Kamiya
- Department of Cardiovascular Research, Research Institute of Environmental Medicine, Nagoya University
| | - Itsuo Kodama
- Department of Cardiovascular Research, Research Institute of Environmental Medicine, Nagoya University
| |
Collapse
|
13
|
Curtis AB, Lopera G. CRT Optimization. JACC Cardiovasc Imaging 2011; 4:699-701. [DOI: 10.1016/j.jcmg.2011.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Revised: 04/22/2011] [Accepted: 04/25/2011] [Indexed: 11/29/2022]
|
14
|
Houthuizen P, Bracke FALE, van Gelder BM. Atrioventricular and interventricular delay optimization in cardiac resynchronization therapy: physiological principles and overview of available methods. Heart Fail Rev 2011; 16:263-76. [PMID: 21431901 PMCID: PMC3074065 DOI: 10.1007/s10741-010-9215-1] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
In this review, the physiological rationale for atrioventricular and interventricular delay optimization of cardiac resynchronization therapy is discussed including the influence of exercise and long-term cardiac resynchronization therapy. The broad spectrum of both invasive and non-invasive optimization methods is reviewed with critical appraisal of the literature. Although the spectrum of both invasive and non-invasive optimization methods is broad, no single method can be recommend for standard practice as large-scale studies using hard endpoints are lacking. Current efforts mainly investigate optimization during resting conditions; however, there is a need to develop automated algorithms to implement dynamic optimization in order to adapt to physiological alterations during exercise and after anatomical remodeling.
Collapse
Affiliation(s)
- Patrick Houthuizen
- Department of Cardiology, Catharina Hospital, P.O. Box 1350, 5602 ZA Eindhoven, The Netherlands.
| | | | | |
Collapse
|
15
|
Golovchiner G, Dorian P, Mangat I, Korley V, Ahmad K, Sharef K, Posan E, Crystal E, O'Donnell S, Pinter A. Electrogram-based optimal atrioventricular and interventricular delays of cardiac resynchronization change individually during exercise. Can J Cardiol 2011; 27:351-7. [PMID: 21489747 DOI: 10.1016/j.cjca.2010.12.047] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2010] [Accepted: 12/16/2010] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Limited data suggest that optimal atrioventricular (AV) and interventricular (VV) delays are different at rest than during exercise in patients with heart failure. We assessed the feasibility and reproducibility of an electrogram-based method of optimization called QuickOpt at rest and during exercise. METHODS Patients with a St Jude Medical cardiac resynchronization therapy implantable cardioverter-defibrillator were subjected to a graded treadmill test, and QuickOpt was repeatedly measured prior to, during, and after the exercise. RESULTS Twenty-four patients (16 males, aged 67.4 ± 7.7 years) participated. At rest, delays (in ms) were 110.4 ± 20.1 for sensed AV delay and -70 (LV pacing first) to +20 (RV pacing first) for VV delay. The changes in QuickOpt-derived delays at rest were not significant despite change in body position. During exercise, QuickOpt-derived AV delays did not change in 11 patients, were shorter during peak exercise in 8 patients, and were longer in 3 patients (average value during peak exercise was 126.5 ± 15.8 ms, P = 0.04 compared to baseline). The QuickOpt-derived VV delay gradually shifted toward earlier right ventricular pacing during exercise in 19 patients, while no changes were seen in 3 patients, and a shift occurred toward earlier left ventricular pacing in 2 patients (average value during peak exercise was -30.7 ± 22.2; P = 0.001 compared to baseline). There was no correlation between changes in the QuickOpt-derived AV and VV delays and heart rate. CONCLUSIONS The application of electrogram-based algorithm is feasible both at rest and during exercise. The results are reproducible. QuickOpt-derived AV and VV delays individually change during exercise.
Collapse
Affiliation(s)
- Gregory Golovchiner
- St. Michael's Hospital, Division of Cardiology, University of Toronto, Toronto, Ontario, Canada.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Maass AH, van Veldhuisen DJ. Heart rates in cardiac resynchronization: the art of optimal device programming. Europace 2011; 13:157-8. [DOI: 10.1093/europace/euq446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
17
|
Echocardiography-Guided Biventricular Pacemaker Optimization. JACC Cardiovasc Imaging 2010; 3:1168-80. [DOI: 10.1016/j.jcmg.2010.06.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2010] [Revised: 05/24/2010] [Accepted: 06/08/2010] [Indexed: 11/18/2022]
|
18
|
BOGAARD MARGOTD, KIRKELS JHANS, HAUER RICHARDN, LOH PETER, DOEVENDANS PIETERA, MEINE MATHIAS. Should We Optimize Cardiac Resynchronization Therapy During Exercise? J Cardiovasc Electrophysiol 2010; 21:1307-16. [DOI: 10.1111/j.1540-8167.2010.01815.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
19
|
Bertini M, Delgado V, Bax JJ, Van de Veire NR. Why, how and when do we need to optimize the setting of cardiac resynchronization therapy? Europace 2009; 11 Suppl 5:v46-57. [DOI: 10.1093/europace/eup275] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
|