1
|
Simpson J, Al-Sadawi M, Deshmukh A, Liang JJ, Latchamsetty R, Crawford T, Jongnarangsin K, Oral H, Bogun F, Ghannam M. Catheter ablation of parahisian premature ventricular complexes in patients with and without cardiac scar. Heart Rhythm 2024:S1547-5271(24)02308-7. [PMID: 38574787 DOI: 10.1016/j.hrthm.2024.03.1813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 03/19/2024] [Accepted: 03/29/2024] [Indexed: 04/06/2024]
Abstract
BACKGROUND Ablation of premature ventricular complexes (PVCs) originating from the parahisian area is challenging. Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) scar may influence procedural outcomes; the impact of cardiac scar on parahisian PVCs has not been described. OBJECTIVE The objective of this study was to examine the incidence and significance of LGE-CMR scarring in patients undergoing ablation for parahisian PVCs. METHODS Consecutive patients who underwent preprocedure LGE-CMR imaging and ablation of parahisian PVCs were included. Acute and long-term outcomes were examined. RESULTS Forty-eight patients were included (male, n = 37; age, 66 ± 10 years; ejection fraction, 50% ± 12%; preprocedure PVC burden, 21% ± 12%). Intramural LGE-CMR scar was present in 33 of 48 (69%) patients. Cryoablation was used in 9 patients; ablation in multiple chambers was required in 28 (58%) patients. The PVC site of origin (SOO) was intramural (n = 25 patients), left ventricular (n = 5), and right ventricular (n = 18). Patients with LGE-CMR scar were more likely to have intramural PVCs (64% vs 27%; P < .04) and to require ablation in multiple cardiac chambers (58% vs 13%; P < .02). Patients with intramural scar required longer duration of ablation delivery (31 ± 20 minutes vs 17 ± 8 minutes; P < .02). Acute procedural success was 69%; PVC burden on follow-up was 6% ± 9% and similar for those with and without scar. CONCLUSION Ablation of parahisian PVCs often requires mapping and ablation of multiple cardiac chambers, with an intramural SOO identified in most patients. An intramural scar was associated with an intramural SOO of the PVCs requiring more extensive ablation procedures, with similar long-term outcomes compared with those without scar.
Collapse
Affiliation(s)
- Jamie Simpson
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Mohamed Al-Sadawi
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Amrish Deshmukh
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Jackson J Liang
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Rakesh Latchamsetty
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Thomas Crawford
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Krit Jongnarangsin
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Hakan Oral
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Frank Bogun
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan
| | - Michael Ghannam
- Division of Cardiovascular Medicine, Department of Electrophysiology, University of Michigan, Ann Arbor, Michigan.
| |
Collapse
|
2
|
Pandozi C, Botto GL, Loricchio ML, D'Ammando M, Lavalle C, Del Giorno G, Matteucci A, Mariani MV, Nicolis D, Segreti L, Papa AA, Casale MC, Galeazzi M, Russo M, Di Belardino N, Pelargonio G, Centurion Aznaran C, Malacrida M, Maddaluno F, Treglia S, Piccolo F, Colivicchi F. High-density mapping of Koch's triangle during sinus rhythm and typical atrioventricular nodal re-entrant tachycardia, integrated with direct recording of atrio-ventricular node structure potential. J Cardiovasc Electrophysiol 2024; 35:379-388. [PMID: 38185855 DOI: 10.1111/jce.16168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/11/2023] [Accepted: 12/15/2023] [Indexed: 01/09/2024]
Abstract
BACKGROUND The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.
Collapse
Affiliation(s)
- Claudio Pandozi
- Division of Cardiology, San Filippo Neri Hospital, Rome, Italy
| | | | | | | | - Carlo Lavalle
- Azienda ospedaliero-universitaria Policlinico Umberto I, Rome, Italy
| | | | - Andrea Matteucci
- Division of Cardiology, San Filippo Neri Hospital, Rome, Italy
- Department of System and Experimental Medicine, University of Rome 'Tor Vergata, Rome, Italy
| | | | | | | | - Andrea Antonio Papa
- Cardiology and Syncope Unit, Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli"-Monaldi Hospital, Naples, Italy
| | | | - Marco Galeazzi
- Division of Cardiology, San Filippo Neri Hospital, Rome, Italy
| | - Maurizio Russo
- Division of Cardiology, San Filippo Neri Hospital, Rome, Italy
| | | | - Gemma Pelargonio
- Istituto di Cardiologia Università Cattolica del Sacro Cuore, Rome, Italy
- Department of Cardiovascular Sciences, Arrhythmology Unit, Fondazione Policlinico Universitario Agostino Gemelli, IRCCS, Rome, Italy
| | | | | | | | | | | | | |
Collapse
|
3
|
Kobza R, Hilfiker G, Rissotto S, Mahida S, Grebmer C, Duru F, Pürerfellner H, Berte B. Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia. Europace 2023; 26:euad372. [PMID: 38193796 PMCID: PMC10775682 DOI: 10.1093/europace/euad372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 12/15/2023] [Indexed: 01/10/2024] Open
Abstract
AIMS High-power ablation is effective for ventricular arrhythmia ablation; however, it increases the risk of steam pops. The aim of this study was to define the safety and efficacy of QMODE ablation in the ventricle and the risk of steam pop. METHODS AND RESULTS Consecutive patients undergoing ventricular ablation using QDOT were included in a prospective single-centre registry. Procedural data, complications, and follow-up were systematically analysed and compared with a historical ventricular tachycardia (VT) and premature ventricular complexes (PVC) cohort ablated using STSF. QMODE (≤50 W) ablation was performed in 107 patients [age 62 ± 13 years; 76% male; VT (n = 41); PVC (n = 66)]. A total of 2456 applications were analysed [power: 45.9 ± 5.0 W with minimal power titration (90% > 95% max power); duration 26 ± 8 s; impedance drop 9.4 ± 4.7 Ω; ablation index: 569 ± 163; mean-max temperature 44.3 ± 2.6°C]. Ventricular tachycardia ablation was associated with shorter radiofrequency (RF) time and a trend towards shorter procedure times using QDOT (QDOT vs. STSF: 20.1 ± 14.7 vs. 31 ± 17 min; P = 0.002, 151 ± 59 vs. 172 ± 48 min; P = 0.06). Complications, VT recurrence, and mortality rates were comparable (QDOT vs. STSF: 2% vs. 2%; P = 0.9, 24% vs. 27%; P = 0.82, and 2% vs. 4%; P = 0.67). Five audible steam pops (0.02%) occurred. Premature ventricular complex ablation was associated with comparable RF and procedure times (QDOT vs. STSF: 4.8 ± 4.6 vs. 3.9 ± 3.1 min; P = 0.25 and 96.1 ± 31.9 vs. 94.6 ± 24.7 min; P = 0.75). Complication and PVC recurrence were also comparable (QDOT vs. STSF: 0% vs. 3%; P = 0.17 and 19% vs. 22%; P = 0.71). CONCLUSION Ventricular ablation using QMODE ≤ 50 W is safe and effective for both VT and PVC ablation and is associated with a low risk for steam pop.
Collapse
Affiliation(s)
- Richard Kobza
- Heart Center, Luzerner Kantonsspital, Zentralstrasse 1, Lucerne 6004, Switzerland
| | - Gabriela Hilfiker
- Heart Center, Luzerner Kantonsspital, Zentralstrasse 1, Lucerne 6004, Switzerland
| | | | - Saagar Mahida
- Department of Cardiac Electrophysiology, Liverpool Heart and Chest Hospital, Liverpool, UK
| | - Christian Grebmer
- Heart Center, Luzerner Kantonsspital, Zentralstrasse 1, Lucerne 6004, Switzerland
| | - Firat Duru
- Cardiology Department, University Hospital Zürich, Zürich, Switzerland
| | | | - Benjamin Berte
- Heart Center, Luzerner Kantonsspital, Zentralstrasse 1, Lucerne 6004, Switzerland
| |
Collapse
|
4
|
Initial Clinical Experience With a Novel 8-Spline High-Resolution Mapping Catheter. JACC Clin Electrophysiol 2022; 8:1067-1076. [PMID: 35780035 DOI: 10.1016/j.jacep.2022.05.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 05/23/2022] [Accepted: 05/25/2022] [Indexed: 11/24/2022]
Abstract
BACKGROUND The Octaray (Biosense Webster) is a novel, multispline mapping catheter with 48 closely spaced microelectrodes enabling high-resolution electroanatomical mapping. OBJECTIVES This study sought to report the initial clinical mapping experience with this novel catheter in a variety of cardiac arrhythmias and to compare the mapping performance with the 5-spline Pentaray. METHODS Fifty consecutive procedures among 46 patients were retrospectively analyzed regarding safety, efficacy, and acute procedural success defined as termination or noninducibility of clinical tachycardia, conduction block across an ablation line, or pulmonary vein isolation. In addition, another 10 patients with sustained atrial tachycardia mapped with the 5-spline catheter (2-5-2 spacing) or the novel 8-spline catheter (2-2-2-2-2 spacing) were analyzed. RESULTS Left atrial and ventricular mapping by either transseptal (n = 41) or retroaortic (n = 2) access was feasible without any complications related to the multispline design of the novel catheter. The acute procedural success rate was 94%. In sustained atrial tachycardia compared with the 5-spline catheter, the novel 8-spline catheter recorded more electrograms per map (3,628 ± 714 vs 11,350 ± 1,203; P < 0.001) in a shorter mapping time (13 ± 2 vs 9 ± 1 minutes; P = 0.08) resulting in a higher point density (18 ± 4 vs 59 ± 10 electrograms/cm2; P < 0.01) and point acquisition rate (308 ± 69 vs 1,332 ± 208 electrograms/min.; P < 0.01). CONCLUSIONS In this initial experience, mapping with the novel catheter was safe and efficient with a high electroanatomical resolution. In sustained atrial tachycardia the novel 8-spline catheter demonstrated a marked increase in point density and mapping speed compared with those of the 5-spline catheter. These initial results should be validated in a larger multicenter cohort with longer follow-up.
Collapse
|
5
|
Anderson RH, Spicer DE, Quintessenza JA, Najm HK, Tretter JT. Words and how we use them-Which is to be the master? J Card Surg 2022; 37:2481-2485. [PMID: 35705190 DOI: 10.1111/jocs.16620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 05/05/2022] [Indexed: 11/30/2022]
Affiliation(s)
- Robert H Anderson
- Department of Cardiovascular Research Centre, Biosciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Diane E Spicer
- Department of Heart Institute, Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA
| | - James A Quintessenza
- Department of Heart Institute, Johns Hopkins All Children's Hospital, St. Petersburg, Florida, USA
| | - Hani K Najm
- Department of Pediatric Cardiac Surgery, Cleveland Clinic Children's, and The Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Justin T Tretter
- Department of Pediatric Cardiology, Cleveland Clinic Children's, and The Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
6
|
Anderson RH, Sanchez-Quintana D, Farre J, Cabrera JA, Tretter JT, Sternick EB. To the Editor- The anatomical correlations to the atrioventricular node. Heart Rhythm 2022; 19:1397. [PMID: 35595018 DOI: 10.1016/j.hrthm.2022.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Accepted: 05/04/2022] [Indexed: 11/04/2022]
Affiliation(s)
- Robert H Anderson
- Institute of Biosciences, Newcastle University, Newcastle upon Tyne, United Kingdom
| | | | - Jeronimo Farre
- Fundación Jiménez Díaz University Hospital and Institute of Biomedical Research, Madrid, Spain
| | - Jose-Angel Cabrera
- Unidad de Arritmias, Departamento de Cardiologıa, Hospital Universitario Quiron-Salud, Universidad Europea, Madrid, Spain
| | - Justin T Tretter
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio
| | - Eduardo Back Sternick
- Arrhythmia and Electrophysiology Department, Biocor Instituto, Nova Lima, Minas Gerais, Brazil.
| |
Collapse
|
7
|
To See More Clearly: Utility of Microelectrodes in Improving Spatio-Temporal Resolution for Para-Hisian Ablation. Heart Rhythm 2021; 19:560-561. [PMID: 34968738 DOI: 10.1016/j.hrthm.2021.12.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 12/23/2021] [Indexed: 11/20/2022]
|