1
|
Yu H, Ahn J, Choi BG, Park S, Kang DO, Choi CU, Rha SW, Jeong MH. Three-Year Clinical Outcomes With the Cilotax Dual Drug-Eluting Stent vs Everolimus-Eluting Stents in Patients With Acute Myocardial Infarction. Tex Heart Inst J 2024; 51:e238271. [PMID: 38686684 PMCID: PMC11075153 DOI: 10.14503/thij-23-8271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
BACKGROUND This study compared the safety and effectiveness of paclitaxel/cilostazol-eluting Cilotax stents with those of everolimus-eluting stents in patients with acute myocardial infarction. Real-world data from the Korea Acute Myocardial Infarction Registry were examined. METHODS A total of 5,472 patients with acute myocardial infarction underwent percutaneous coronary intervention with Cilotax stents (n = 212) or everolimus-eluting stents (n = 5,260). The primary end point was the 3-year rate of target lesion failure. The other end points were major adverse cardiovascular events (a composite of cardiac death, target vessel myocardial infarction, and ischemia-driven target lesion revascularization), target vessel revascularization, and stent thrombosis. A propensity score matching analysis was performed to adjust for potential confounders by using a logistic regression model; propensity score matching generated 2 well-balanced groups (Cilotax group, n = 180; everolimus-eluting stents group, n = 170; N = 350). After propensity score matching, baseline clinical characteristics were similar between the groups. RESULTS After percutaneous coronary intervention, compared with the everolimus-eluting stents group, the Cilotax group more often had major adverse cardiovascular events (24.1% vs 18.5%; P = .042), myocardial infarction (8.0% vs 3.2%; P < .001), target lesion revascularization (8.0% vs 2.6%; P < .001), target vessel revascularization (11.3% vs 4.5%; P < .001), and stent thrombosis (4.7% vs 0.5%; P < .001) before matching. Even after matching, the Cilotax group had more frequent target lesion revascularization (9.4% vs 2.9%; P = .22) and stent thrombosis (5.6% vs 1.2%; P = .34). CONCLUSION In patients with acute myocardial infarction who underwent percutaneous coronary intervention, use of the Cilotax stent was associated with higher rates of target lesion revascularization, target vessel revascularization, and stent thrombosis than were everolimus-eluting stents. Use of the Cilotax dual drugeluting stent should be avoided in the treatment of myocardial infarction.
Collapse
Affiliation(s)
- HyeYon Yu
- School of Nursing, College of Medicine, Soonchunhyang University, Asan, Republic of Korea
| | - Jihun Ahn
- Department of Internal Medicine, Daejeon Eulji Medical Center, Eulji University College of Medicine, Daejeon, Republic of Korea
| | - Byoung Geol Choi
- Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Soohyung Park
- Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Dong Oh Kang
- Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Cheol Ung Choi
- Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Seung-Woon Rha
- Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Myung Ho Jeong
- Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| |
Collapse
|
3
|
Ma YL, Tang XF, Yao Y, Xu N, Song Y, Jiang P, Xu JJ, Wang HH, Jiang L, Liu R, Zhao XY, Chen J, Gao Z, Qiao SB, Yang YJ, Gao RL, Xu B, Yuan JQ. Comparison of Efficacy and Safety between First- and Second-Generation Drug-Eluting Stents in Patients with Acute Coronary Syndrome. Chin Med J (Engl) 2018; 131:1397-1405. [PMID: 29893356 PMCID: PMC6006822 DOI: 10.4103/0366-6999.233959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background: It remains undetermined whether second-generation drug-eluting stents (G2-DESs) outperform first-generation DESs (G1-DESs) in patients with acute coronary syndrome (ACS). We aimed to compare the efficacy and safety of G1-DES and G2-DES in ACS patients in a high-volume cardiovascular center. Methods: In 2013, 10,724 consecutive patients underwent percutaneous coronary intervention in our institution. We included 4037 patients with ACS who underwent exclusively G1-DES or G2-DES implantation (n = 364 and n = 3673, respectively). We used propensity score matching to minimize the imbalance between the G1-DES and G2-DES groups and followed patients for 2 years. The efficacy endpoints were major adverse cardiac events (MACEs) and its components including target vessel-related myocardial infarction (TV-MI), target vessel revascularization/target lesion revascularization (TVR/TLR), and cardiac death. The safety endpoint was stent thrombosis. Continuous variables were compared by Mann-Whitney U-test, and categorical variables were compared using Pearson's Chi-square or Fisher's exact test. Kaplan-Meier curves were constructed to compare the event-free survival rates, and multivariate Cox proportional hazards regression analysis was used to assess whether stent type was an independent risk factor for the efficacy and safety endpoints. Results: At the 2-year follow-up, the results for MACE and it components, as well as stent thrombosis, were similar for G1-DES and G2-DES (MACE, 5.2% vs. 4.3%, χ2 = 0.514, P = 0.474; TV-MI, 0.8% vs. 0.4%, P = 0.407; TVR, 4.9% vs. 3.7%, χ2 = 0.939, P = 0.333; TLR, 3.8% vs. 2.5%, χ2 = 1.610, P = 0.205; cardiac death, 0.3% vs. 0.5%, P = 0.670; and stent thrombosis, 0.5% vs. 0.4%, P > 0.999). Kaplan-Meier analysis indicated similar event-free survival rates between G1-DES and G2-DES after propensity score matching (all: log-rank P > 0.05). Multivariate analysis demonstrated that stent type was not an independent risk factor for the efficacy and safety endpoints (MACE, hazard ratio [HR] = 0.805, 95% confidence interval [CI]: 0.455–1.424, P = 0.456; TV-MI, HR = 0.500, 95% CI: 0.101–2.475, P = 0.395; TVR, HR = 0.732, 95% CI: 0.403–1.330, P = 0.306; TLR, HR = 0.629, 95% CI: 0.313–1.264, P = 0.193; cardiac death, HR = 1.991, 95% CI: 0.223–17.814, P = 0.538; and stent thrombosis, HR = 0.746, 95% CI: 0.125–4.467, P = 0.749). Conclusion: G1-DES and G2-DES have similar efficacy and safety profiles in ACS patients at the 2-year follow-up.
Collapse
Affiliation(s)
- Yuan-Liang Ma
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Xiao-Fang Tang
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Yi Yao
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Na Xu
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Ying Song
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Ping Jiang
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Jing-Jing Xu
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Huan-Huan Wang
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Lin Jiang
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Ru Liu
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Xue-Yan Zhao
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Jue Chen
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Zhan Gao
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Shu-Bin Qiao
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Yue-Jin Yang
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Run-Lin Gao
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Bo Xu
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Jin-Qing Yuan
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| |
Collapse
|
4
|
Tang W, Yeh J, Chen J, Liu M, Ke J, Tan G, Lin X, Wu W. Meta-analysis of randomized controlled trials on efficacy and safety of extended thienopyridine therapy after drug-eluting stent implantation. Cardiovasc Diagn Ther 2016; 6:409-416. [PMID: 27747163 DOI: 10.21037/cdt.2016.03.09] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND The potential benefits and risks of extended thienopyridine therapy beyond 12 months after drug-eluting stent (DES) implantation remain unclear. METHODS Randomized controlled trials (RCTs) were searched in PubMed, EMBASE, the Cochrane Library and China National Knowledge Infrastructure databases. The adverse clinical endpoints were compared between 12 months group (aspirin alone) and >12 months group (additional thienopyridine plus aspirin after 12-month dual antiplatelet therapy). Odds ratios (ORs) with 95% confidence intervals (95% CIs) were used as summary statistics. A random-effect model was used in the meta-analysis process. RESULTS Finally, three RCTs incorporating 16,265 participants were included in this meta-analysis. The results indicated that the incidences of myocardial infarction (1.55% vs. 2.90%; OR =0.58; 95% CI, 0.40-0.84; P=0.004) and stent thrombosis (0.32% vs. 0.98%; OR =0.35; 95% CI, 0.20-0.62; P<0.001) in the >12 months group were significantly lower than the 12 months group. However, compared to the 12 months group, the extended thienopyridine therapy markedly increased the risk of bleeding events (2.09% vs. 1.28%; OR =1.64; 95% CI, 1.23-2.17; P<0.001). The risks of stroke (0.78% vs. 0.84%; P=0.67) and cardiac death (0.94% vs. 0.89%; P=0.61) were similar between the two groups. CONCLUSIONS The synthesis of available evidence indicates that a regimen of extended thienopyridine therapy beyond 12 months may significantly reduce the risks of myocardial infarction and stent thrombosis but increase the risk of bleeding events in the patients who have received DESs implantation.
Collapse
Affiliation(s)
- Wenyi Tang
- Department of Cardiology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519099, China
| | - James Yeh
- National Heart and Lung Institute, Imperial College London, London, UK
| | - Jian Chen
- Department of Cardiology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519099, China
| | - Mao Liu
- Department of Cardiology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519099, China
| | - Jianting Ke
- Department of Nephrology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519000, China
| | - Guangyi Tan
- Department of Cardiology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519099, China
| | - Xiufang Lin
- Department of Cardiology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519099, China
| | - Wei Wu
- Department of Cardiology, the Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai 519099, China
| |
Collapse
|
5
|
Zhang F, Yang J, Qian J, Ge L, Zhou J, Ge J. Long-term performance of the second-generation cobalt-chromium sirolimus-eluting stents in real-world clinical practice: 3-year clinical outcomes from the prospective multicenter FOCUS registry. J Thorac Dis 2016; 8:1601-10. [PMID: 27499948 DOI: 10.21037/jtd.2016.05.11] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND The short- and mid-term outcomes of the second-generation cobalt-chromium sirolimus-eluting stent (CoCr-SES) in real-world patients had been reported previously, but the long-term performance remained unclear. The objective of this analysis was to evaluate the long-term safety and efficacy of the second-generation CoCr-SES from the FOCUS registry. METHODS The FOCUS registry (ClinicalTrials.gov Identifier: NCT00868829) enrolled all-comers eligible to receive Firebird-2 CoCr-SES. Follow-up was continued to 3 years to evaluate long-term safety and effectiveness of the second-generation CoCr-SES in real-world practice. Results of the extended-use group and standard-use group are compared to explore performance of CoCr-SES in more severe patients with more complex lesions. RESULTS The rate of 3-year MACE was 7.37%, consisting of 84 cases (1.78%) of cardiac death, 166 cases (3.52%) of MI and 98 cases (2.08%) of TVR. ARC definite/probable stent thrombosis happened in 34 (0.72%) patients, only 3 new cases (<0.1%) of very late stent thrombosis was reported in the third year. Meanwhile, the difference of MACE (7.77% vs. 6.06%; P=0.058), TLF (4.71% vs. 3.49%; P=0.085) and ARC definite/probable stent thrombosis (0.83% vs. 0.37%; P=0.116) between extended-use group and standard-use group showed no significance. CONCLUSIONS The second-generation CoCr-SES was associated with continued low rates of 3-year MACE, TLF and stent thrombosis in a broad spectrum of patients.
Collapse
Affiliation(s)
- Feng Zhang
- Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Ji'e Yang
- Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Juying Qian
- Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Lei Ge
- Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Jun Zhou
- Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Junbo Ge
- Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | | |
Collapse
|