1
|
Tobe A, Garg S, Möllmann H, Rück A, Kim WK, Buono A, Scotti A, Latib A, Toggweiler S, Mangieri A, Laine M, Meduri CU, Rheude T, Wong I, Pruthvi CR, Tsai TY, Onuma Y, Serruys PW. Short-Term Outcomes of ACURATE neo2. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100277. [PMID: 38799801 PMCID: PMC11121741 DOI: 10.1016/j.shj.2023.100277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 12/02/2023] [Accepted: 12/21/2023] [Indexed: 05/29/2024]
Abstract
Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.
Collapse
Affiliation(s)
- Akihiro Tobe
- Department of Cardiology, University of Galway, Galway, Ireland
| | - Scot Garg
- Department of Cardiology, Royal Blackburn Hospital, Blackburn, UK
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Andreas Rück
- Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden
| | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart and Thorax Center, Bad Nauheim, Germany
| | - Andrea Buono
- Cardiovascular Department, Interventional Cardiology Unit, Fondazione Poliambulanza Institute, Brescia, Italy
| | - Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | | | - Antonio Mangieri
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Mika Laine
- Department of Cardiology, Heart and Lung Center, Helsinki University and Helsinki University Central Hospital, Helsinki, Finland
| | | | - Tobias Rheude
- Department of Cardiovascular Diseases, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Ivan Wong
- Division of Cardiology, Queen Elizabeth Hospital, Kowloon, Hong Kong
| | | | - Tsung-Ying Tsai
- Department of Cardiology, University of Galway, Galway, Ireland
- Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan
| | - Yoshinobu Onuma
- Department of Cardiology, University of Galway, Galway, Ireland
| | | |
Collapse
|
2
|
Elkoumy A, Rück A, Abdel-Wahab M, Thiele H, Rudolph TK, Wolf A, Wambach JM, De Backer O, Sondergaard L, Hengstenberg C, Abdelshafy M, Arsang-Jang S, Elzomor H, Laine M, Bjursten H, Götberg M, Wykrzykowska JJ, Mohamed SK, Pellegrini C, Rheude T, Toggweiler S, Saleh N, Meduri CU, Kim WK, Soliman O. ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty - direct ACURATE neo2. Int J Cardiol 2024; 400:131792. [PMID: 38244892 DOI: 10.1016/j.ijcard.2024.131792] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/10/2024] [Accepted: 01/16/2024] [Indexed: 01/22/2024]
Abstract
BACKGROUND ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.
Collapse
Affiliation(s)
- Ahmed Elkoumy
- Discipline of Cardiology, Saolta, Galway University Hospital, Health Service Executive and CORRIB Core Lab, University of Galway, Galway, Ireland; Islamic Center of Cardiology, Al-Azhar University, Nasr City, Cairo, Egypt
| | - Andreas Rück
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | - Mohamed Abdel-Wahab
- Department of Cardiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany
| | - Holger Thiele
- Department of Cardiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany
| | - Tanja K Rudolph
- Heart and Diabetes Center Nordrhine Westphalia, Department of General and Interventional Cardiology/Angiology, Bad Oeynhausen, Ruhr-University Bochum, Germany
| | - Alexander Wolf
- Department of Cardiology, Contilia Heart and Vascular Center, Elisabeth-Krankenhaus, Essen, Germany
| | - Jan Martin Wambach
- Department of Cardiology, Contilia Heart and Vascular Center, Elisabeth-Krankenhaus, Essen, Germany
| | - Ole De Backer
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | | | - Christian Hengstenberg
- Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna, Vienna, Austria
| | - Mahmoud Abdelshafy
- Discipline of Cardiology, Saolta, Galway University Hospital, Health Service Executive and CORRIB Core Lab, University of Galway, Galway, Ireland; Department of Cardiology, Al-Azhar University Hospitals, Cairo, Egypt
| | - Shahram Arsang-Jang
- Discipline of Cardiology, Saolta, Galway University Hospital, Health Service Executive and CORRIB Core Lab, University of Galway, Galway, Ireland; CÚRAM, SFI Research Centre for Medical Devices, Galway, Ireland
| | - Hesham Elzomor
- Discipline of Cardiology, Saolta, Galway University Hospital, Health Service Executive and CORRIB Core Lab, University of Galway, Galway, Ireland
| | - Mika Laine
- Department of Cardiology, Heart and Lung Centre, Helsinki University Hospital, Helsinki, Finland
| | - Henrik Bjursten
- Department of Cardiothoracic Surgery, Anaesthesia and Intensive Care, Lund University, Skåne University Hospital, Lund, Sweden
| | - Matthias Götberg
- Department of Cardiology, Clinical Sciences. Lund University, Skåne University Hospital, Lund, Sweden
| | - Joanna J Wykrzykowska
- Interventional Cardiology, Department of Cardiology, University of Groningen, University Medical Center Groningen, the Netherlands
| | - Sameh K Mohamed
- Discipline of Cardiology, Saolta, Galway University Hospital, Health Service Executive and CORRIB Core Lab, University of Galway, Galway, Ireland
| | - Costanza Pellegrini
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich, Germany
| | - Tobias Rheude
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich, Germany
| | - Stefan Toggweiler
- Department of Cardiology, Heart Center Lucerne, Luzerner Kantonsspital|LUKS, Lucerne, Switzerland
| | - Nawzad Saleh
- Karolinska University Hospital, Department of Cardiology, Stockholm, Sweden
| | | | - Won-Keun Kim
- Department of Cardiology and Cardiac Surgery, Kerckhoff Heart, and Lung Centre, Bad Nauheim, Germany
| | - Osama Soliman
- Discipline of Cardiology, Saolta, Galway University Hospital, Health Service Executive and CORRIB Core Lab, University of Galway, Galway, Ireland; CÚRAM, SFI Research Centre for Medical Devices, Galway, Ireland.
| |
Collapse
|