1
|
Using a novel ambulatory monitoring system to support patient safety on an acute infectious disease ward during an unfolding pandemic. J Adv Nurs 2024; 80:2452-2461. [PMID: 38054397 DOI: 10.1111/jan.15977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 10/16/2023] [Accepted: 11/09/2023] [Indexed: 12/07/2023]
Abstract
AIM To gain staff feedback on the implementation and impact of a novel ambulatory monitoring system to support coronavirus patient management on an isolation ward. DESIGN Qualitative service evaluation. METHODS Semi-structured interviews were conducted with 15 multidisciplinary isolation ward staff in the United Kingdom between July 2020 and May 2021. Interviews were audio-recorded, transcribed and analysed using thematic analysis. FINDINGS Adopting Innovation to Assist Patient Safety was identified as the overriding theme. Three interlinked sub-themes represent facets of how the system supported patient safety. Patient Selection was developed throughout the pandemic, as clinical staff became more confident in choosing which patients would benefit most. Trust In the System described how nurses coped with discrepancies between the ambulatory system and ward observation machines. Finally, Resource Management examined how, once trust was built, staff perceived the ambulatory system assisted with caseload management. This supported efficient personal protective equipment resource use by reducing the number of isolation room entries. Despite these reported benefits, face-to-face contact was still highly valued, despite the risk of coronavirus exposure. CONCLUSION Hospital wards should consider using ambulatory monitoring systems to support caseload management and patient safety. Patients in isolation rooms or at high risk of deterioration may particularly benefit from this additional monitoring. However, these systems should be seen as an adjunct to nursing care, not a replacement. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE Nurses valued ambulatory monitoring as a means of ensuring the safety of patients at risk of deterioration and prioritizing their workload. IMPACT The findings of this research will be useful to all those developing or considering implementation of ambulatory monitoring systems in hospital wards. REPORTING METHOD This manuscript follows the Consolidated criteria for Reporting Qualitative Research (COREQ) guidelines with inclusion of relevant SQUIRE guidelines for reporting quality improvement. PATIENT OR PUBLIC CONTRIBUTION No Patient or Public Contribution.
Collapse
|
2
|
Barriers to and Facilitators of Key Stakeholders Influencing Successful Digital Implementation of Remote Monitoring Solutions: Mixed Methods Analysis. JMIR Hum Factors 2024; 11:e49769. [PMID: 37338929 PMCID: PMC11106697 DOI: 10.2196/49769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 01/26/2024] [Accepted: 04/07/2024] [Indexed: 06/21/2023] Open
Abstract
BACKGROUND Implementation of remote monitoring solutions and digital alerting tools in health care has historically been challenging, despite the impetus provided by the COVID-19 pandemic. To date, a health systems-based approach to systematically describe barriers and facilitators across multiple domains has not been undertaken. OBJECTIVE We aimed to undertake a comprehensive mixed methods analysis of barriers and facilitators for successful implementation of remote monitoring and digital alerting tools in complex health organizations. METHODS A mixed methods approach using a modified Technology Acceptance Model questionnaire and semistructured interviews mapped to the validated fit among humans, organizations, and technology (HOT-fit) framework was undertaken. Likert frequency responses and deductive thematic analyses were performed. RESULTS A total of 11 participants responded to the questionnaire and 18 participants to the interviews. Key barriers and facilitators could be mapped onto 6 dimensions, which incorporated aspects of digitization: system use (human), user satisfaction (human), environment (organization), structure (organization), information and service quality (technology), and system quality (technology). CONCLUSIONS The recommendations proposed can enhance the potential for future remote sensing solutions to be more successfully integrated in health care practice, resulting in more successful use of "virtual wards." TRIAL REGISTRATION ClinicalTrials.gov NCT05321004; https://www.clinicaltrials.gov/study/NCT05321004.
Collapse
|
3
|
The patient experience of in-hospital telemetry monitoring: a qualitative analysis. Eur J Cardiovasc Nurs 2024; 23:258-266. [PMID: 37590960 DOI: 10.1093/eurjcn/zvad082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 08/07/2023] [Accepted: 08/08/2023] [Indexed: 08/19/2023]
Abstract
AIMS In-hospital telemetry monitoring has been an integrated part of arrhythmia monitoring for decades. A substantial proportion of patients require arrhythmia monitoring during stays in non-intensive care units. However, studies exploring patients' experiences of telemetry monitoring are scarce. Therefore, the aim was to explore and describe patients' experiences of in-hospital telemetry monitoring in a non-intensive care setting. METHODS AND RESULTS Twenty face-to-face, semi-structured interviews were conducted. Interviews were conducted before discharge at two university hospitals in Norway. The patients were purposively sampled, resulting in a well-balanced population comprising 11 men and nine women, mean age 62 years (range 25-83). Average monitoring time was 9 days (range 3-14). Data were audiotaped, transcribed verbatim, and coded using NVivo software. Qualitative content analysis using an inductive approach was performed. Patients expressed a need for individualized information during telemetry monitoring. Their feelings of safety were related to responses from nurses from the central monitoring station when alarms from the telemetry were triggered. Despite perceived physical restrictions and psychological limitations associated with telemetry monitoring, they found monitoring to be beneficial because it facilitated the diagnosis of arrhythmia. Moreover, they expressed a need for improvements in wearable monitoring equipment. Patients expressed ambivalent feelings about discontinuing the telemetry and their readiness for discharge. CONCLUSION Patients need individualized information about the results of their telemetry monitoring in order to better understand the arrhythmia management and to increase their experience of safety after discharge. The limitations patients experienced should be taken into consideration in further upgrades of telemetry monitoring equipment.
Collapse
|
4
|
Continuous ward monitoring and intensive postoperative management. Chin Med J (Engl) 2024; 137:631-632. [PMID: 38384165 PMCID: PMC10950178 DOI: 10.1097/cm9.0000000000002997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Indexed: 02/23/2024] Open
|
5
|
Three Years of Continuous Vital Signs Monitoring on the General Surgical Ward: Is It Sustainable? A Qualitative Study. J Clin Med 2024; 13:439. [PMID: 38256573 PMCID: PMC10816891 DOI: 10.3390/jcm13020439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 01/24/2024] Open
Abstract
Continuous monitoring of vital signs using a wireless wearable device was implemented in 2018 at a surgical care unit of an academic hospital. This study aimed at gaining insight into nurses' and patients' perspectives regarding the use and innovation of a continuous vital signs monitoring system, three years after its introduction. This qualitative study was performed in a surgical, non-intensive care unit of an academic hospital in 2021. Key-user nurses (nurses with additional training and expertise with the device) and patients were selected for semi-structured interviews, and nurses from the ward were selected for a focus group interview using a topic list. Transcripts of the audio tapes were deductively analysed using four dimensions for adoptions of information and communication technologies (ICT) devices in healthcare. The device provided feelings of safety for nurses and patients. Nurses and patients had a few issues with the device, including the size and the battery life. Nurses gained knowledge and skills in using the system for measurement and interpretations. They perceived the system as a tool to improve the recognition of clinical decline. The use of the system could be further developed regarding the technical device's characteristics, nurses' interpretation of the data and the of type of alarms, the information needs of patients, and clarification of the definition and standardization of continuous monitoring. Three years after the introduction, wireless continuous vital signs monitoring is the new standard of care according to the end-users at the general surgical ward.
Collapse
|
6
|
Continuous Vital Signs Monitoring with a Wireless Device on a General Ward: A Survey to Explore Nurses' Experiences in a Post-Implementation Period. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:ijerph20105794. [PMID: 37239523 DOI: 10.3390/ijerph20105794] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/10/2023] [Accepted: 04/20/2023] [Indexed: 05/28/2023]
Abstract
BACKGROUND Nurse engagement, perceived need and usefulness affect healthcare technology use, acceptance and improvements in quality, safety and accessibility of healthcare. Nurses' opinions regarding continuous monitoring appear to be positive. However, facilitators and barriers were little studied. This study explored nurses' post-implementation experiences of the facilitators and barriers to continuously monitoring patients' vital signs using a wireless device on general hospital wards. METHODS This study employed a cross-sectional survey. Vocational and registered nurses from three general wards in a Dutch tertiary university hospital participated in a survey comprising open and closed questions. The data were analysed using thematic analysis and descriptive statistics. RESULTS Fifty-eight nurses (51.3%) completed the survey. Barriers and facilitators were identified under four key themes: (1) timely signalling and early action, (2) time savings and time consumption, (3) patient comfort and satisfaction and (4) preconditions. CONCLUSIONS According to nurses, early detection and intervention for deteriorating patients facilitate the use and acceptance of continuously monitoring vital signs. Barriers primarily concern difficulties connecting patients correctly to the devices and system.
Collapse
|
7
|
Potential for remote vital sign monitoring to improve hospital patient sleep: A feasibility study. Int J Med Inform 2023; 170:104970. [PMID: 36603390 DOI: 10.1016/j.ijmedinf.2022.104970] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/20/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND Even low-acuity patients suffer from disrupted sleep in the hospital in part due to routine overnight vital sign (VS) checks. When invasive monitoring is not needed, vital sign monitoring devices (VSMDs) similar to consumer-grade health monitors may play a role in promoting sleep, which can aid healing and recovery. METHODS We provided one VSMD to neuroscience ward patients during their hospital stays and used surveys to assess patient and nurse attitudes toward the device and the impact of the device on patient comfort. We also compared VSMD-streamed vS data to nurse-recorded vS data in the chart to evaluate the consistency of data streaming and data concordance between the device and nurse-collected vital sign values. FINDINGS 21 patients and 15 nurses enrolled. Overall, patients and nurses responded positively to the device and patients preferred wearing the device to receiving manual vital checks overnight. The most common device-related cause of sleep disruption per patients was device weight (29%). Device vS were concordant with nurse vS on average but there was significant variance in agreement between nurse and device values. INTERPRETATION Patients and nurses feel positively about the use of VSMDs and their use in the hospital. The device we tested may be limited in its sleep promotion by its weight and patient comfort assessment. Further research is needed to assess the precision of the device in measuring vital signs when used in a clinical setting. Future studies should compare VSMD models and assess their impacts on patient sleep in the absence of manual vS checks overnight. FUNDING Funding provided by the Sara & Evan Williams Foundation Endowed Neurohospitalist Chair at UCSF.
Collapse
|
8
|
Healthcare provider and patient/family perceptions of continuous pressure imaging technology for prevention of pressure injuries: A secondary analysis of patients enrolled in a randomized control trial. PLoS One 2022; 17:e0278019. [PMID: 36445905 PMCID: PMC9707747 DOI: 10.1371/journal.pone.0278019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 11/08/2022] [Indexed: 12/02/2022] Open
Abstract
INTRODUCTION Despite the availability of various pressure injury (PI) prevention strategies (e.g., risk identification, use of pressure re-distribution surfaces, frequent repositioning), they persist as a significant issue for healthcare systems worldwide. Continuous pressure imaging (CPI) is a novel technology that could be integrated within a comprehensive approach to the prevention of PIs. We studied the perceptions of healthcare providers and patients/families to identify facilitators and barriers to the use of this technology. METHODS Hospitalized patients/family members from a randomized controlled trial assessing the efficacy of CPI in preventing PIs completed a survey after 72 hours (or upon discharge from hospital) of CPI monitoring. They were asked questions about prior and current experience with CPI technology. For healthcare providers, perceptions on the use of the device and its impact on care were explored through a survey distributed by email or hard copies. RESULTS A total of 125 healthcare providers and 525 patients/family members completed the surveys. Of the healthcare providers, 95% either agreed/strongly agreed that the CPI technology was easy to use and 65% stated that the device improved how they provided pressure relief for patients. Identified issues with the device were cost, the fitting of the mattress cover, and the fixation of the patients/families on the device. Over a quarter of the patient/family respondents agreed/strongly agreed that the device influenced how pressure relief was provided. This response was statistically associated with whether the monitor was turned on (intervention arm; 52.7%) or off (control arm; 4.2%). DISCUSSION AND CONCLUSION CPI technology was positively perceived by healthcare providers. Most patients/families felt it influenced care when the CPI monitor was turned on. Concerns raised around cost and the ease of use of these devices by healthcare providers may affect the decisions of healthcare system administrators to adopt and implement this technology.
Collapse
|
9
|
Key Stakeholder Barriers and Facilitators to Implementing Remote Monitoring Technologies: Protocol for a Mixed Methods Analysis. JMIR Res Protoc 2022; 11:e38437. [PMID: 35862185 PMCID: PMC9353674 DOI: 10.2196/38437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 06/08/2022] [Accepted: 06/24/2022] [Indexed: 11/13/2022] Open
Abstract
Background The implementation of novel digital solutions within the National Health Service has historically been challenging. Since the start of the COVID-19 pandemic, there has been a greater push for digitization and for operating remote monitoring solutions. However, the implementation and widespread adoption of this type of innovation have been poorly studied. Objective We aim to investigate key stakeholder barriers and facilitators to implementing remote monitoring solutions to identify factors that could affect successful adoption. Methods A mixed methods approach will be implemented. Semistructured interviews will be conducted with high-level stakeholders from industry and academia and health care providers who have played an instrumental role in, and have prior experience with, implementing digital solutions, alongside the use of an adapted version of the Technology Acceptance Model questionnaire. Results Enrollment is currently underway, having started in February 2022. It is anticipated to end in July 2022, with data analysis scheduled to commence in August 2022. Conclusions The results of our study may highlight key barriers and facilitators to implementing digital remote monitoring solutions, thereby allowing for improved widespread adoption within the National Health Service in the future. Trial Registration ClinicalTrials.gov NCT05321004; https://clinicaltrials.gov/ct2/show/NCT05321004
Collapse
|
10
|
Outcomes of Vital Sign Monitoring of an Acute Surgical Cohort With Wearable Sensors and Digital Alerting Systems: A Pragmatically Designed Cohort Study and Propensity-Matched Analysis. Front Bioeng Biotechnol 2022; 10:895973. [PMID: 35832414 PMCID: PMC9271673 DOI: 10.3389/fbioe.2022.895973] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 06/06/2022] [Indexed: 11/15/2022] Open
Abstract
Background: The implementation and efficacy of wearable sensors and alerting systems in acute secondary care have been poorly described. Objectives: to pragmatically test one such system and its influence on clinical outcomes in an acute surgical cohort. Methods: In this pragmatically designed, pre-post implementation trial, participants admitted to the acute surgical unit at our institution were recruited. In the pre-implementation phase (September 2017 to May 2019), the SensiumVitals™ monitoring system, which continuously measures temperature, heart, and respiratory rates, was used for monitoring alongside usual care (intermittent monitoring in accordance with the National Early Warning Score 2 [NEWS 2] protocol) without alerts being generated. In the post-implementation phase (May 2019 to March 2020), alerts were generated when pre-established thresholds for vital parameters were breached, requiring acknowledgement from healthcare staff on provided mobile devices. Hospital length of stay, intensive care use, and 28-days mortality were measured. Balanced cohorts were created with 1:1 ‘optimal’ propensity score logistic regression models. Results: The 1:1 matching method matched the post-implementation group (n = 141) with the same number of subjects from the pre-implementation group (n = 141). The median age of the entire cohort was 52 (range: 18–95) years and the median duration of wearing the sensor was 1.3 (interquartile range: 0.7–2.0) days. The median alert acknowledgement time was 111 (range: 1–2,146) minutes. There were no significant differences in critical care admission (planned or unplanned), hospital length of stay, or mortality. Conclusion: This study offered insight into the implementation of digital health technologies within our institution. Further work is required for optimisation of digital workflows, particularly given their more favourable acceptability in the post pandemic era. Clinical trials registration information: ClinicalTrials.gov Identifier: NCT04638738.
Collapse
|
11
|
Nurses' experiences with continuous vital sign monitoring on the general surgical ward: a qualitative study based on the Behaviour Change Wheel. BMC Nurs 2022; 21:60. [PMID: 35287678 PMCID: PMC8919550 DOI: 10.1186/s12912-022-00837-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 03/02/2022] [Indexed: 11/18/2022] Open
Abstract
Background To support early recognition of clinical deterioration on a general ward continuous vital signs monitoring (CMVS) systems using wearable devices are increasingly being investigated. Although nurses play a crucial role in successful implementation, reported nurse adoption and acceptance scores vary significantly. In-depth insight into the perspectives of nurses regarding CMVS is lacking. To this end, we applied a theoretical approach for behaviour change derived from the Behaviour Change Wheel (BCW). Aim To provide insight in the capability, opportunity and motivation of nurses working with CMVS, in order to inform future implementation efforts. Methods A qualitative study was conducted, including twelve nurses of a surgical ward in a tertiary teaching hospital with previous experience of working with CMVS. Semi-structured interviews were audiotaped, transcribed verbatim, and analysed using thematic analysis. The results were mapped onto the Capability, Opportunity, Motivation – Behaviour (COM-B) model of the BCW. Results Five key themes emerged. The theme ‘Learning and coaching on the job’ linked to Capability. Nurses favoured learning about CVSM by dealing with it in daily practice. Receiving bedside guidance and coaching was perceived as important. The theme ‘interpretation of vital sign trends’ also linked to Capability. Nurses mentioned the novelty of monitoring vital sign trends of patients on wards. The theme ‘Management of alarms’ linked to Opportunity. Nurses perceived the (false) alarms generated by the system as excessive resulting in feelings of irritation and uncertainty. The theme ‘Integration and compatibility with clinical workflow’ linked to Opportunity. CVSM was experienced as helpful and easy to use, although integration in mobile devices and the EMR was highly favoured and the management of clinical workflows would need improvement. The theme ‘Added value for nursing care’ linked to Motivation. All nurses recognized the potential added value of CVSM for postoperative care. Conclusion Our findings suggest all parts of the COM-B model should be considered when implementing CVSM on general wards. When the themes in Capability and Opportunity are not properly addressed by selecting interventions and policy categories, this may negatively influence the Motivation and may compromise successful implementation. Supplementary Information The online version contains supplementary material available at 10.1186/s12912-022-00837-x.
Collapse
|
12
|
Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study. PLoS One 2022; 17:e0265435. [PMID: 35286354 PMCID: PMC8947816 DOI: 10.1371/journal.pone.0265435] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 03/01/2022] [Indexed: 11/19/2022] Open
Abstract
Background Wireless continuous vital sign monitoring by wearable devices have recently become available for patients on general wards to promote timely detection of clinical deterioration. Many continuous monitoring systems use conventional threshold alarm settings to alert nurses in case of deviating vital signs. However, frequent false alarms often lead to alarm fatigue and inefficiencies in the workplace. The aim of this study was to determine the feasibility of continuous vital sign monitoring without the use of alarms, thereby exclusively relying on interval trend monitoring. Methods This explanatory sequential mixed methods study was conducted at an abdominal surgical ward of a tertiary teaching hospital. Heart rate and respiratory rate of patients were measured every minute by a wearable sensor. Trends were visualized and assessed six times per day by nurses and once a day by doctors during morning rounds. Instead of using alarms we focused exclusively on regular vital sign trend analysis by nurses and doctors. Primary outcome was feasibility in terms of acceptability by professionals, assessed by the Usefulness, Satisfaction and Ease of Use questionnaire and further explored in two focus groups, as well as fidelity. Results A total of 56 patients were monitored and in 80.5% (n = 536) of nurses’ work shifts the trends assessments were documented. All deviating trends (n = 17) were recognized in time. Professionals (N = 46) considered continuous monitoring satisfying (4.8±1.0 on a 1–7 Likert-scale) and were willing to use the technology. Although insight into vital sign trends allowed faster anticipation and action upon changed patient status, professionals were neutral about usefulness (4.4±1.0). They found continuous monitoring easy to use (4.7±0.8) and easy to learn (5.3±1.0) but indicated the need for gaining practical experience. Nurses considered the use of alarms for deviating vital signs unnecessary, when trends were regularly assessed and reported. Conclusion We demonstrated that continuous vital signs trend monitoring without using alarms was feasible in the general ward setting, thereby avoiding unnecessary alarms and preventing alarm fatigue. When monitoring in a general ward setting, the standard use of alarms may therefore be reconsidered.
Collapse
|
13
|
Remote Monitoring of Chronic Critically Ill Patients after Hospital Discharge: A Systematic Review. J Clin Med 2022; 11:jcm11041010. [PMID: 35207287 PMCID: PMC8879658 DOI: 10.3390/jcm11041010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/29/2022] [Accepted: 02/11/2022] [Indexed: 12/22/2022] Open
Abstract
Background: Over the past few decades, critical care has seen many advancements. These advancements resulted in a considerable increase in the prevalence of chronically critically ill patients requiring prolonged medical care, which led to a massive increase in healthcare utilization. Methods: We performed a search for suitable articles using PubMed and Google Scholar from the inception of these databases to 15 May 2021. Results: Thirty-four articles were included in the review and analyzed. We described the following characteristics and problems with chronic critically ill patient management: the patient population, remote monitoring, the monitoring of physiological parameters in chronic critically ill patients, the anatomical location of sensors, the barriers to implementation, and the main technology-related issues. The main challenges in the management of these patients are (1) the shortage of caretakers, (2) the periodicity of vital function monitoring (e.g., episodic measuring of blood pressure leads to missing important critical events such as hypertension, hypotension, and hypoxia), and (3) failure to catch and manage critical physiological events at the right time, which can result in poor outcomes. Conclusions: The prevalence of critically ill patients is expected to grow. Technical solutions can greatly assist medical personnel and caregivers. Wearable devices can be used to monitor blood pressure, heart rate, pulse, respiratory rate, blood oxygen saturation, metabolism, and central nervous system function. The most important points that should be addressed in future studies are the performance of the remote monitoring systems, safety, clinical and economic outcomes, as well as the acceptance of the devices by patients, caretakers, and healthcare professionals.
Collapse
|
14
|
Abstract
Background Wearable devices have been proposed as a novel method for monitoring patients after surgery to track recovery, identify complications early, and improve surgical safety. Previous studies have used a heterogeneous range of devices, methods, and analyses. This review aimed to examine current methods and wearable devices used for monitoring after abdominal surgery and identify knowledge gaps requiring further investigation. Methods A scoping review was conducted given the heterogeneous nature of the evidence. MEDLINE, EMBASE, and Scopus databases were systematically searched. Studies of wearable devices for monitoring of adult patients within 30 days after abdominal surgery were eligible for inclusion. Results A total of 78 articles from 65 study cohorts, with 5153 patients were included. Thirty-one different wearable devices were used to measure vital signs, physiological measurements, or physical activity. The duration of postoperative wearable device use ranged from 15 h to 3 months after surgery. Studies mostly focused on physical activity metrics (71.8 per cent). Continuous vital sign measurement and physical activity tracking both showed promise for detecting postoperative complications earlier than usual care, but conclusions were limited by poor device precision, adherence, occurrence of false alarms, data transmission problems, and retrospective data analysis. Devices were generally well accepted by patients, with high levels of acceptance, comfort, and safety. Conclusion Wearable technology has not yet realized its potential to improve postoperative monitoring. Further work is needed to overcome technical limitations, improve precision, and reduce false alarms. Prospective assessment of efficacy, using an intention-to-treat approach should be the focus of further studies.
Collapse
|
15
|
Experiences of current vital signs monitoring practices and views of wearable monitoring: A qualitative study in patients and nurses. J Adv Nurs 2021; 78:810-822. [PMID: 34655093 PMCID: PMC9293408 DOI: 10.1111/jan.15055] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/07/2021] [Accepted: 09/23/2021] [Indexed: 11/26/2022]
Abstract
Aims To understand current experiences of vital signs monitoring of patients and clinical staff on a surgical ward, and views on the introduction of wearable ambulatory monitoring into the general ward environment. Design Qualitative study. Methods Semi‐structured interviews using topic guides were conducted with 15 patients and 15 nurses on a surgical ward between July 2018 and August 2019. The concept of ambulatory wearable devices for clinical monitoring was introduced at the end of the interview. Results Three interconnected themes were identified. Vital sign data as evidence for escalation, examined nurses' use of data to support escalation of care and the implications for patients perceived to be deteriorating who have not reached the threshold for escalation. The second theme, Trustworthiness of vital sign data, described nurses’ practice of using manual measurements to recheck or confirm automated vital signs readings when concerned. The final theme, finding a balance between continuous and intermittent monitoring, both patients and nurses agreed that although continuous monitoring may improve safety and reassurance, these needed to be balanced with multiple limitations. Factors to be considered included noise pollution, comfort, and impact on patient mobility and independence. Introduction of the concept of ambulatory wearable devices was viewed positively by both groups as offering solutions to some of the issues identified with traditional monitoring. However, most agreed that this would not be suitable for all patients and should not replace direct nurse/patient contact. Conclusion Both patients and staff identified the benefits of continuous monitoring to improve patient safety but, due to limitations, use should be carefully considered and patient‐centred. Impact Feedback from nurses and patients suggests there is scope for ambulatory monitoring systems to be integrated into the hospital environment; however, both groups emphasized these should not add more noise to the ward nor replace direct nursing contact.
Collapse
|
16
|
The impact of wearable continuous vital sign monitoring on deterioration detection and clinical outcomes in hospitalised patients: a systematic review and meta-analysis. Crit Care 2021; 25:351. [PMID: 34583742 PMCID: PMC8477465 DOI: 10.1186/s13054-021-03766-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 09/11/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Timely recognition of the deteriorating inpatient remains challenging. Wearable monitoring systems (WMS) may augment current monitoring practices. However, there are many barriers to implementation in the hospital environment, and evidence describing the clinical impact of WMS on deterioration detection and patient outcome remains unclear. OBJECTIVE To assess the impact of vital-sign monitoring on detection of deterioration and related clinical outcomes in hospitalised patients using WMS, in comparison with standard care. METHODS A systematic search was conducted in August 2020 using MEDLINE, Embase, CINAHL, Cochrane Database of Systematic Reviews, CENTRAL, Health Technology Assessment databases and grey literature. Studies comparing the use of WMS against standard care for deterioration detection and related clinical outcomes in hospitalised patients were included. Deterioration related outcomes (primary) included unplanned intensive care admissions, rapid response team or cardiac arrest activation, total and major complications rate. Other clinical outcomes (secondary) included in-hospital mortality and hospital length of stay. Exploratory outcomes included alerting system parameters and clinical trial registry information. RESULTS Of 8706 citations, 10 studies with different designs met the inclusion criteria, of which 7 were included in the meta-analyses. Overall study quality was moderate. The meta-analysis indicated that the WMS, when compared with standard care, was not associated with significant reductions in intensive care transfers (risk ratio, RR 0.87; 95% confidence interval, CI 0.66-1.15), rapid response or cardiac arrest team activation (RR 0.84; 95% CI 0.69-1.01), total (RR 0.77; 95% CI 0.44-1.32) and major (RR 0.55; 95% CI 0.24-1.30) complications prevalence. There was also no statistically significant association with reduced mortality (RR 0.48; 95% CI 0.18-1.29) and hospital length of stay (mean difference, MD - 0.09; 95% CI - 0.43 to 0.44). CONCLUSION This systematic review indicates that there is no current evidence that implementation of WMS impacts early deterioration detection and associated clinical outcomes, as differing design/quality of available studies and diversity of outcome measures make it difficult to reach a definite conclusion. Our narrative findings suggested that alarms should be adjusted to minimise false alarms and promote rapid clinical action in response to deterioration. PROSPERO Registration number: CRD42020188633 .
Collapse
|
17
|
Short-Term Wearable Sensors for In-Hospital Medical and Surgical Patients: Mixed Methods Analysis of Patient Perspectives. JMIR Perioper Med 2021; 4:e18836. [PMID: 33885367 PMCID: PMC8103292 DOI: 10.2196/18836] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 12/18/2020] [Accepted: 01/13/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Continuous vital sign monitoring using wearable sensors may enable early detection of patient deterioration and sepsis. OBJECTIVE This study aimed to explore patient experiences with wearable sensor technology and carry out continuous monitoring through questionnaire and interview studies in an acute hospital setting. METHODS Patients were recruited for a wearable sensor study and were asked to complete a 9-item questionnaire. Patients responses were evaluated using a Likert scale and with continuous variables. A subgroup of surgical patients wearing a Sensium Vital Sign Sensor was invited to participate in semistructured interviews. The Sensium wearable sensor measures the vital signs: heart rate, respiratory rate, and temperature. All interview data were subjected to thematic analysis. RESULTS Out of a total of 500 patients, 453 (90.6%) completed the questionnaire. Furthermore, 427 (85.4%) patients agreed that the wearable sensor was comfortable, 429 (85.8%) patients agreed to wear the patch again when in hospital, and 398 (79.6%) patients agreed to wear the patch at home. Overall, 12 surgical patients consented to the interviews. Five main themes of interest to patients emerged from the interviews: (1) centralized monitoring, (2) enhanced feelings of patient safety, (3) impact on nursing staff, (4) comfort and usability, and (5) future use and views on technology. CONCLUSIONS Overall, the feedback from patients using wearable monitoring sensors was strongly positive with relatively few concerns raised. Patients felt that the wearable sensors would improve their sense of safety, relieve pressure on health care staff, and serve as a favorable aspect of future health care technology.
Collapse
|
18
|
Enhancing instructional outcomes with a serious gamified system: a qualitative investigation of student perceptions. INFORMATION AND LEARNING SCIENCES 2021. [DOI: 10.1108/ils-05-2020-0162] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose
This paper aims to evaluate the students’ perception of their learning experiences concerning serious gaming and gamification instructions and determines whether they were motivated enough and engaged during the educative process in a resource-poor context. Moreover, the study evaluated the impact of interactive instructional environment outcomes in terms of students’ perceptions of the learning catalysed by gamified systems, particularly in enhancing attitude change coupled with knowledge acquisition.
Design/methodology/approach
This study used a qualitative research design technique to collect the data. A total of 108 first year secondary school students participated in a sexual health literacy course that lasted for a five-week learning period. Using a cluster-sampling technique, three classes were randomly assigned to serious gaming, gamification and teacher-centred instructions. Individual face-to-face interviews were used to assess students’ perceives required satisfaction with three instructions. Data were audio-recorded, and coding analysis was used using NVivo software facilitated qualitative data analysis.
Findings
The results show that serious gaming and gamification instructions trumped the traditional teacher-centred instruction method. While intervention students were all positive about the serious gaming and gamification instructions, non-intervention students were negative about conservative teacher-centered learning whose limited interactivity also undermined learning relative to the two innovative interventions.
Research limitations/implications
As a justification to limit face-to-face classes, this study may be useful during an emergency phenomenon, including the current situation of amid COVID-19. The implementation of serious gaming and gamification as remotely instructional options could be among the measures to protect educational communities through reducing close-proximity, and eventually, control contamination and the spread of viruses.
Originality/value
The application of serious gaming and game elements should not be conceptualised as universal but context-specific. This study shows that particularism is essential to optimise the results in terms of coming up with a specific design based on the scope of evaluation for positive results and develop an intervention that will work, especially in the resource-poor context of the developing world.
Collapse
|
19
|
The pilot, proof of concept REMOTE-COVID trial: remote monitoring use in suspected cases of COVID-19 (SARS-CoV 2). BMC Public Health 2021; 21:638. [PMID: 33794832 PMCID: PMC8013165 DOI: 10.1186/s12889-021-10660-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 03/18/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND SARS-CoV-2 has ever-increasing attributed deaths. Vital sign trends are routinely used to monitor patients with changes in these parameters preceding an adverse event. Wearable sensors can measure vital signs continuously and remotely, outside of hospital facilities, recognising early clinical deterioration. We aim to determine the feasibility & acceptability of remote monitoring systems for quarantined individuals in a hotel suspected of COVID-19. METHODS A pilot, proof-of-concept, feasibility trial was conducted in engineered hotels near London airports (May-June 2020). Individuals arriving to London with mild suspected COVID-19 symptoms requiring quarantine, as recommended by Public Health England, or healthcare professionals with COVID-19 symptoms unable to isolate at home were eligible. The SensiumVitals™ patch, measuring temperature, heart & respiratory rates, was applied on arrival for the duration of their stay. Alerts were generated when pre-established thresholds were breeched; trained nursing staff could consequently intervene. RESULTS Fourteen individuals (M = 7, F = 7) were recruited; the mean age was 34.9 (SD 11) years. Mean length of stay was 3 (SD 1.8) days. In total, 10 vital alerts were generated across 4 participants, resulting in telephone contact, reassurance, or adjustment of the sensor. No individuals required hospitalisation or virtual general practitioner review. DISCUSSION This proof-of-concept trial demonstrated the feasibility of a rapidly implemented model of healthcare delivery through remote monitoring during a pandemic at a hotel, acting as an extension to a healthcare trust. Benefits included reduced viral exposure to healthcare staff, with recognition of clinical deterioration through ambulatory, continuous, remote monitoring using a discrete wearable sensor. CONCLUSION Remote monitoring systems can be applied to hotels to deliver healthcare safely in individuals suspected of COVID-19. Further work is required to evaluate this model on a larger scale. TRIAL REGISTRATION Clinical trials registration information: ClinicalTrials.gov Identifier: NCT04337489 (07/04/2020).
Collapse
|
20
|
Abstract
This paper presents a model of a smart healthcare service for stress management in dental patients during the interventions. The main goal is to provide dental clinics with a model that enables introducing a stress management service into everyday practice and provides patients with a better experience in a typically stressful situation. The approach is based on employing wearable sensors for monitoring physiological parameters, and a mobile application for progressive muscle relaxation therapy. Dental patients were divided into experimental and control groups. Participants from the experimental group were treated with progressive muscle relaxation through mobile health application with audio content, and patients from the control group were not exposed to any relaxation method. Heart rate was measured in both groups through three test phases: pre-intervention, intervention, and post-intervention. Evaluation of the anxiety level was performed using the STAI test. Results show that the measured heart rate in the post-intervention phase is lower than in the intervention phase in both testing groups, as well as in the pre-intervention phase. STAI scores were significantly higher in the control group through all test phases. The research found that the proposed system applied to dentist patients may relieve their anxiety symptoms and decrease stress level, which improves the patients' experience and leads to higher patients' satisfaction.
Collapse
|
21
|
Abstract
OBJECTIVE To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. DESIGN Observational cohort study. SETTING Tertiary teaching hospital. PARTICIPANTS Postoperative abdominal surgical patients (n=30) and nurses (n=23). INTERVENTIONS Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. OUTCOMES System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. RESULTS Thirty patients were monitored for a median duration of 81 hours (IQR 47-143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1-4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2-4.8) and satisfaction 3.7 (IQR 3.2-4.8), but agreed on ease of learning at 5.0 (IQR 4.0-5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. CONCLUSIONS Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses' ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
Collapse
|
22
|
Abstract
During the course of surgical interventions, complications mostly occur in the postoperative period. Slight clinical indications can be observed, which precede a significant deterioration of the patient's condition. On the general ward vital parameters, such as heart and breathing frequencies are measured every 4-8 h. Even if the monitoring of critically ill patients is increased to every 2 h and the measurement of vital functions takes 10 min, the patient is only monitored for 120 min in a 24 h period and remains postoperatively on the general ward without monitoring for 22 out of 24 h. New wireless monitoring systems are available to continuously register some vital functions with the aid of wearable sensors. These systems can alert and alarm ward personnel if the patient's condition deteriorates. Although the optimal monitoring system does not yet exist and implementation of these new wireless monitoring systems might involve some risks, these new methods offer a great opportunity to optimize surveillance of postoperative patients on the general ward.
Collapse
|
23
|
Non-contact vital sign monitoring of patients in an intensive care unit: A human factors analysis of staff expectations. APPLIED ERGONOMICS 2021; 90:103149. [PMID: 32866689 DOI: 10.1016/j.apergo.2020.103149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 01/12/2020] [Accepted: 05/06/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Infra-red and thermal imaging enable wireless systems to monitor patients' vital signs and absence of wires may improve patient experiences. No studies have explored staff perceptions of the concept of this specific type of technology in the adult population. Understanding existing working systems before introducing technology could improve adoption. METHODS We conducted semi-structured interviews with Intensive Care Unit (ICU) staff exploring perceptions of wireless patient monitoring. We used the Systems Engineering Initiative for Patient Safety (SEIPS) model to guide thematic analysis. RESULTS We identified usability themes relating to staff perceptions of current patient monitoring experiences, staff perceptions of patient/relative expectations of ICU care, troubleshooting, hierarchy of monitoring, and consensus of trust. CONCLUSION The concept of wireless monitoring has perceived benefits for patients and staff. The Systems Engineering Initiative for Patient Safety model guided a systems-based exploratory evaluation. Results highlight the social and environmental factors which may influence usability, adoption, or abandonment of wireless technology in the ICU.
Collapse
|
24
|
Parkinson's disease: current assessment methods and wearable devices for evaluation of movement disorder motor symptoms - a patient and healthcare professional perspective. BMC Neurol 2020; 20:419. [PMID: 33208135 PMCID: PMC7677815 DOI: 10.1186/s12883-020-01996-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 11/09/2020] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Parkinson's disease is the second most common long-term chronic, progressive, neurodegenerative disease, affecting more than 10 million people worldwide. There has been a rising interest in wearable devices for evaluation of movement disorder diseases such as Parkinson's disease due to the limitations in current clinic assessment methods such as Unified Parkinson's Disease Rating Scale (UPDRS) and the Hoehn and Yahr (HY) scale. However, there are only a few commercial wearable devices available, which, in addition, have had very limited adoption and implementation. This inconsistency may be due to a lack of users' perspectives in terms of device design and implementation. This study aims to identify the perspectives of healthcare professionals and patients linked to current assessment methods and to identify preferences, and requirements of wearable devices. METHODS This was a qualitative study using semi-structured interviews followed by focus groups. Transcripts from sessions were analysed using an inductive thematic approach. RESULTS It was noted that the well-known assessment process such as Unified Parkinson's Disease Rating Scale (UPDRS) was not used routinely in clinics since it is time consuming, subjective, inaccurate, infrequent and dependent on patients' memories. Participants suggested that objective assessment methods are needed to increase the chance of effective treatment. The participants' perspectives were positive toward using wearable devices, particularly if they were involved in early design stages. Patients emphasized that the devices should be comfortable, but they did not have any concerns regarding device visibility or data privacy transmitted over the internet when it comes to their health. In terms of wearing a monitor, the preferable part of the body for all participants was the wrist. Healthcare professionals stated a need for an economical solution that is easy to interpret. Some design aspects identified by patients included clasps, material choice, and form factor. CONCLUSION The study concluded that current assessment methods are limited. Patients' and healthcare professionals' involvement in wearable devices design process has a pivotal role in terms of ultimate user acceptance. This includes the provision of additional functions to the wearable device, such as fall detection and medication reminders, which could be attractive features for patients.
Collapse
|
25
|
|
26
|
Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic Review. J Med Internet Res 2020; 22:e18636. [PMID: 32469323 PMCID: PMC7351263 DOI: 10.2196/18636] [Citation(s) in RCA: 84] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/07/2020] [Accepted: 05/14/2020] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND Continuous monitoring of vital signs by using wearable wireless devices may allow for timely detection of clinical deterioration in patients in general wards in comparison to detection by standard intermittent vital signs measurements. A large number of studies on many different wearable devices have been reported in recent years, but a systematic review is not yet available to date. OBJECTIVE The aim of this study was to provide a systematic review for health care professionals regarding the current evidence about the validation, feasibility, clinical outcomes, and costs of wearable wireless devices for continuous monitoring of vital signs. METHODS A systematic and comprehensive search was performed using PubMed/MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials from January 2009 to September 2019 for studies that evaluated wearable wireless devices for continuous monitoring of vital signs in adults. Outcomes were structured by validation, feasibility, clinical outcomes, and costs. Risk of bias was determined by using the Mixed Methods Appraisal Tool, quality assessment of diagnostic accuracy studies 2nd edition, or quality of health economic studies tool. RESULTS In this review, 27 studies evaluating 13 different wearable wireless devices were included. These studies predominantly evaluated the validation or the feasibility outcomes of these devices. Only a few studies reported the clinical outcomes with these devices and they did not report a significantly better clinical outcome than the standard tools used for measuring vital signs. Cost outcomes were not reported in any study. The quality of the included studies was predominantly rated as low or moderate. CONCLUSIONS Wearable wireless continuous monitoring devices are mostly still in the clinical validation and feasibility testing phases. To date, there are no high quality large well-controlled studies of wearable wireless devices available that show a significant clinical benefit or cost-effectiveness. Such studies are needed to help health care professionals and administrators in their decision making regarding implementation of these devices on a large scale in clinical practice or in-home monitoring.
Collapse
|
27
|
Situation Awareness-Oriented Patient Monitoring with Visual Patient Technology: A Qualitative Review of the Primary Research. SENSORS (BASEL, SWITZERLAND) 2020; 20:E2112. [PMID: 32283625 PMCID: PMC7180744 DOI: 10.3390/s20072112] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 04/01/2020] [Accepted: 04/04/2020] [Indexed: 12/15/2022]
Abstract
Visual Patient technology is a situation awareness-oriented visualization technology that translates numerical and waveform patient monitoring data into a new user-centered visual language. Vital sign values are converted into colors, shapes, and rhythmic movements-a language humans can easily perceive and interpret-on a patient avatar model in real time. In this review, we summarize the current state of the research on the Visual Patient, including the technology, its history, and its scientific context. We also provide a summary of our primary research and a brief overview of research work on similar user-centered visualizations in medicine. In several computer-based studies under various experimental conditions, Visual Patient transferred more information per unit time, increased perceived diagnostic certainty, and lowered perceived workload. Eye tracking showed the technology worked because of the way it synthesizes and transforms vital sign information into new and logical forms corresponding to the real phenomena. The technology could be particularly useful for improving situation awareness in settings with high cognitive demand or when users must make quick decisions. This comprehensive review of Visual Patient research is the foundation for an evaluation of the technology in clinical applications, starting with a high-fidelity simulation study in early 2020.
Collapse
|
28
|
|
29
|
Wearable devices for remote vital signs monitoring in the outpatient setting: an overview of the field. ACTA ACUST UNITED AC 2020. [DOI: 10.1136/bmjinnov-2019-000354] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Early detection of physiological deterioration has been shown to improve patient outcomes. Due to recent improvements in technology, comprehensive outpatient vital signs monitoring is now possible. This is the first review to collate information on all wearable devices on the market for outpatient physiological monitoring.A scoping review was undertaken. The monitors reviewed were limited to those that can function in the outpatient setting with minimal restrictions on the patient’s normal lifestyle, while measuring any or all of the vital signs: heart rate, ECG, oxygen saturation, respiration rate, blood pressure and temperature.A total of 270 papers were included in the review. Thirty wearable monitors were examined: 6 patches, 3 clothing-based monitors, 4 chest straps, 2 upper arm bands and 15 wristbands. The monitoring of vital signs in the outpatient setting is a developing field with differing levels of evidence for each monitor. The most common clinical application was heart rate monitoring. Blood pressure and oxygen saturation measurements were the least common applications. There is a need for clinical validation studies in the outpatient setting to prove the potential of many of the monitors identified.Research in this area is in its infancy. Future research should look at aggregating the results of validity and reliability and patient outcome studies for each monitor and between different devices. This would provide a more holistic overview of the potential for the clinical use of each device.
Collapse
|
30
|
Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial. BMJ Open 2019; 9:e031150. [PMID: 31420399 PMCID: PMC6701670 DOI: 10.1136/bmjopen-2019-031150] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVE To validate whether a wearable remote vital signs monitor could accurately measure heart rate (HR), respiratory rate (RR) and temperature in a postsurgical patient population at high risk of complications. DESIGN Manually recorded vital signs data were paired with vital signs data derived from the remote monitor set in patients participating in the Trial of Remote versus Continuous INtermittent monitoring (TRaCINg) study: a trial of continuous remote vital signs monitoring. SETTING St James's University Hospital, UK. PARTICIPANTS 51 patients who had undergone major elective general surgery. INTERVENTIONS The intervention was the SensiumVitals monitoring system. This is a wireless patch worn on the patient's chest that measures HR, RR and temperature continuously. The reference standard was nurse-measured manually recorded vital signs. PRIMARY AND SECONDARY OUTCOME MEASURES The primary outcomes were the 95% limits of agreement between manually recorded and wearable patch vital sign recordings of HR, RR and temperature. The secondary outcomes were the percentage completeness of vital sign patch data for each vital sign. RESULTS 1135 nurse observations were available for analysis. There was no clinically meaningful bias in HR (1.85 bpm), but precision was poor (95% limits of agreement -23.92 to 20.22 bpm). Agreement was poor for RR (bias 2.93 breaths per minute, 95% limits of agreement -8.19 to 14.05 breaths per minute) and temperature (bias 0.82°C, 95% limits of agreement -1.13°C to 2.78°C). Vital sign patch data completeness was 72.8% for temperature, 59.2% for HR and 34.1% for RR. Distributions of RR in manually recorded measurements were clinically implausible. CONCLUSIONS The continuous monitoring system did not reliably provide HR consistent with nurse measurements. The accuracy of RR and temperature was outside of acceptable limits. Limitations of the system could potentially be overcome through better signal processing. While acknowledging the time pressures placed on nursing staff, inaccuracies in the manually recorded data present an opportunity to increase awareness about the importance of manual observations, particularly with regard to methods of manual HR and RR measurements.
Collapse
|
31
|
Patient acceptability of wearable vital sign monitoring technologies in the acute care setting: A systematic review. J Clin Nurs 2019; 28:2732-2744. [PMID: 31017338 DOI: 10.1111/jocn.14893] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 03/19/2019] [Accepted: 04/14/2019] [Indexed: 11/28/2022]
Abstract
AIMS AND OBJECTIVES To examine patient acceptability of wearable vital sign monitoring devices in the acute setting. BACKGROUND Wearable vital sign monitoring devices may improve patient safety, yet hospital patients' acceptability of these devices is largely unreported. DESIGN A systematic review. METHODS Cumulative Index to Nursing and Allied Health Literature Complete, MEDLINE Complete and EMBASE were searched, supplemented by reference list hand searching. Studies were included if they involved adult hospital patients (≥18 years), a wearable monitoring device capable of assessing ≥1 vital sign, and measured patient acceptability, satisfaction or experience of wearing the device. No date restrictions were enforced. Quality assessments of quantitative and qualitative studies were undertaken using the Downs and Black Checklist for Measuring Study Quality and the Critical Appraisal Skills Programme Qualitative Research Checklist, respectively. Meta-analyses were not possible given data heterogeneity and low research quality. Reporting adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and a Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist was completed. RESULTS Of the 427 studies screened, seven observational studies met the inclusion criteria. Six studies were of low quality and one was of high quality. In two studies, patient satisfaction was investigated. In the remaining studies, patient experience, patient opinions and experience, patient perceptions and experience, device acceptability, and patient comfort and concerns were investigated. In four studies, patients were mostly accepting of the wearable devices, reporting positive experiences and satisfaction relating to their use. In three studies, findings were mixed. CONCLUSION There is limited high-quality research examining patient acceptability of wearable vital sign monitoring devices as an a priori focus in the acute setting. Further understanding of patient perspectives of these devices is required to inform their continued use and development. RELEVANCE TO CLINICAL PRACTICE The provision of patient-centred nursing care is contingent on understanding patients' preferences, including their acceptability of technology use.
Collapse
|
32
|
Postanesthesia care by remote monitoring of vital signs in surgical wards. Curr Opin Anaesthesiol 2018; 31:716-722. [DOI: 10.1097/aco.0000000000000650] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|