1
|
Brás M, Freitas H, Gonçalves P, Seco J. In vivo dosimetry for proton therapy: A Monte Carlo study of the Gadolinium spectral response throughout the course of treatment. Med Phys 2025; 52:2412-2424. [PMID: 39838583 PMCID: PMC11972047 DOI: 10.1002/mp.17625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 12/03/2024] [Accepted: 12/22/2024] [Indexed: 01/23/2025] Open
Abstract
BACKGROUND In proton radiotherapy, the steep dose deposition profile near the end of the proton's track, the Bragg peak, ensures a more conformed deposition of dose to the tumor region when compared with conventional radiotherapy while reducing the probability of normal tissue complications. However, uncertainties, as in the proton range, patient geometry, and positioning pose challenges to the precise and secure delivery of the treatment plan (TP). In vivo range determination and dose distribution are pivotal for mitigation of uncertainties, opening the possibility to reduce uncertainty margins and for adaptation of the TP. PURPOSE This study aims to explore the feasibility of utilizing gadolinium (Gd), a highly used contrast agent in MRI, as a surrogate for in vivo dosimetry during the course of scanning proton therapy, tracking the delivery of a TP and the impact of uncertainties intra- and inter-fraction in the course of treatment. METHODS Monte Carlo simulations (Geant4 11.1.1) were performed, where a Gd-filled volume was placed within a water phantom and underwent treatment with a scanning proton TP delivering 4 Gy. The secondary photons emitted upon proton-Gd interaction were recorded and assessed for various tumor displacements. The spectral response of Gd to each pencil beam irradiation is therefore used as a surrogate for dose measurements during treatment. RESULTS Results show that the deposited dose at the target volume can be tracked for each TP scanning point by correlating it with the recorded Gd signal. The analyzed Gd spectral line corresponded to the characteristic X-rayk α $\text{k}_\alpha$ line at 43 keV. Displacements from the planned geometry could be distinguished by observing changes in the Gd signal induced by each pencil beam. Moreover, the total 43 keV signal recorded subsequently to the full TP delivery reflected deviations from the planned integral dose to the target. CONCLUSIONS The study suggests that the spectral response of a Gd-based contrast agent can be used for in vivo dosimetry, providing insights into the TP delivery. The Gd 43 keV spectral line was correlated with the dose at the tumor, its volume, and its position. Other variables that can impact the method, such as the kinetic energy of the incident protons and Gd concentration in the target were also discussed.
Collapse
Affiliation(s)
- Mariana Brás
- German Cancer Research CentreHeidelbergGermany
- Laboratório de Intrumentação e Física Experimental de PartículasLisbonPortugal
- Department of PhysicsInstituto Superior Técnico University of LisbonLisbonPortugal
| | - Hugo Freitas
- German Cancer Research CentreHeidelbergGermany
- Department of Physics and AstronomyUniversity of HeidelbergHeidelbergGermany
| | - Patrícia Gonçalves
- Laboratório de Intrumentação e Física Experimental de PartículasLisbonPortugal
- Department of PhysicsInstituto Superior Técnico University of LisbonLisbonPortugal
| | - João Seco
- German Cancer Research CentreHeidelbergGermany
- Department of Physics and AstronomyUniversity of HeidelbergHeidelbergGermany
| |
Collapse
|
2
|
Liu Z, Pan L, Ma T, Lu H, Wang Y. Comprehensive beam delivery latency evaluation for gated proton therapy system using customized multi-channel signal acquisition platform. J Appl Clin Med Phys 2024; 25:e14349. [PMID: 38551392 PMCID: PMC11087162 DOI: 10.1002/acm2.14349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Revised: 03/04/2024] [Accepted: 03/08/2024] [Indexed: 05/12/2024] Open
Abstract
PURPOSE Beam delivery latency in respiratory-gated particle therapy systems is a crucial issue to dose delivery accuracy. The aim of this study is to develop a multi-channel signal acquisition platform for investigating gating latencies occurring within RPM respiratory gating system (Varian, USA) and ProBeam proton treatment system (Varian, USA) individually. METHODS The multi-channel signal acquisition platform consisted of several electronic components, including a string position sensor for target motion detection, a photodiode for proton beam sensing, an interfacing board for accessing the trigger signal between the respiratory gating system and the proton treatment system, a signal acquisition device for sampling and synchronizing signals from the aforementioned components, and a laptop for controlling the signal acquisition device and data storage. RPM system latencies were determined by comparing the expected gating phases extracted from the motion signal with the trigger signal's state turning points. ProBeam system latencies were assessed by comparing the state turning points of the trigger signal with the beam signal. The total beam delivery latencies were calculated as the sum of delays in the respiratory gating system and the cyclotron proton treatment system. During latency measurements, simulated sinusoidal motion were applied at different amplitudes and periods for complete beam delivery latency evaluation under different breathing patterns. Each breathing pattern was repeated 30 times for statistical analysis. RESULTS The measured gating ON/OFF latencies in the RPM system were found to be 104.20 ± 13.64 ms and 113.60 ± 14.98 ms, respectively. The measured gating ON/OFF delays in the ProBeam system were 108.29 ± 0.85 ms and 1.20 ± 0.04 ms, respectively. The total beam ON/OFF latencies were determined to be 212.50 ± 13.64 ms and 114.80 ± 14.98 ms. CONCLUSION With the developed multi-channel signal acquisition platform, it was able to investigate the gating lags happened in both the respiratory gating system and the proton treatment system. The resolution of the platform is enough to distinguish the delays at the millisecond time level. Both the respiratory gating system and the proton treatment system made contributions to gating latency. Both systems contributed nearly equally to the total beam ON latency, with approximately 100 ms. In contrast, the respiratory gating system was the dominant contributor to the total beam OFF latency.
Collapse
Affiliation(s)
- Zhipeng Liu
- Hefei Ion Medical Centerthe First Affiliated Hospital of USTCDivision of Life Sciences and MedicineUniversity of Science and Technology of ChinaHefeiChina
| | - Lingjing Pan
- Hefei Ion Medical Centerthe First Affiliated Hospital of USTCDivision of Life Sciences and MedicineUniversity of Science and Technology of ChinaHefeiChina
| | - Tao Ma
- Hefei Ion Medical Centerthe First Affiliated Hospital of USTCDivision of Life Sciences and MedicineUniversity of Science and Technology of ChinaHefeiChina
| | - Hsiao‐Ming Lu
- Hefei Ion Medical Centerthe First Affiliated Hospital of USTCDivision of Life Sciences and MedicineUniversity of Science and Technology of ChinaHefeiChina
- Ion Medical Research InstituteUniversity of Science and Technology of ChinaHefeiChina
| | - Yuanyuan Wang
- Hefei Ion Medical Centerthe First Affiliated Hospital of USTCDivision of Life Sciences and MedicineUniversity of Science and Technology of ChinaHefeiChina
| |
Collapse
|
3
|
Spautz S, Jakobi A, Meijers A, Peters N, Löck S, Knopf AC, Troost EGC, Richter C, Stützer K. Experimental validation of 4D log file-based proton dose reconstruction for interplay assessment considering amplitude-sorted 4DCTs. Med Phys 2022; 49:3538-3549. [PMID: 35342943 DOI: 10.1002/mp.15625] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 02/01/2022] [Accepted: 03/13/2022] [Indexed: 11/06/2022] Open
Abstract
PURPOSE The unpredictable interplay between dynamic proton therapy delivery and target motion in the thorax can lead to severe dose distortions. A fraction-wise four-dimensional (4D) dose reconstruction workflow allows for the assessment of the applied dose after patient treatment while considering the actual beam delivery sequence extracted from machine log files, the recorded breathing pattern and the geometric information from a 4D computed tomography scan (4DCT). Such an algorithm capable of accounting for amplitude-sorted 4DCTs was implemented and its accuracy as well as its sensitivity to input parameter variations was experimentally evaluated. METHODS An anthropomorphic thorax phantom with a movable insert containing a target surrogate and a radiochromic film was irradiated with a monoenergetic field for various 1D target motion forms (sin, sin4) and peak-to-peak amplitudes (5/10/15/20/30 mm). The measured characteristic film dose distributions were compared to the respective sections in the 4D reconstructed doses using a 2D γ-analysis (3mm, 3%); γ-pass rates were derived for different dose grid resolutions (1mm/3mm) and deformable image registrations (DIR, automatic/manual) applied during the 4D dose reconstruction process. In an additional analysis, the sensitivity of reconstructed dose distributions against potential asynchronous timing of the motion and machine log files was investigated for both a monoenergetic field and more realistic 4D robustly optimized fields by artificially introduced offsets of ± 1/5/25/50/250 ms. The resulting dose distributions with asynchronized log files were compared to those with synchronized log files by means of a 3D γ-analysis (1mm, 1%) and the evaluation of absolute dose differences. RESULTS The induced characteristic interplay patterns on the films were well reproduced by the 4D dose reconstruction with 2D γ-pass rates ≥95% for almost all cases with motion magnitudes ≤15 mm. In general, the 2D γ-pass rates showed a significant decrease for larger motion amplitudes and increase when using a finer dose grid resolution but were not affected by the choice of motion form (sin, sin4). There was also a trend, though not statistically significant, towards the manually defined DIR for better quality of the reconstructed dose distributions in the area imaged by the film. The 4D dose reconstruction results for the monoenergetic as well as the 4D robustly optimized fields were robust against small asynchronies between motion and machine log files of up to 5 ms, which is in the order of potential network latencies. CONCLUSIONS We have implemented a 4D log file-based proton dose reconstruction that accounts for amplitude-sorted 4DCTs. Its accuracy was proven to be clinically acceptable for target motion magnitudes of up to 15 mm. Particular attention should be paid to the synchronization of the log file generating systems as the reconstructed dose distribution may vary with log file asynchronies larger than those caused by realistic network delays. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Saskia Spautz
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany
| | - Annika Jakobi
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Arturs Meijers
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Steffen Löck
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Antje-Christin Knopf
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.,Department 1 of Internal Medicine, Center for Integrated Oncology Cologne, University Hospital of Cologne, Cologne, Germany
| | - Esther G C Troost
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany.,National Center for Tumor Diseases (NCT), Partner Site Dresden, Germany: German Cancer Research Center (DKFZ), Heidelberg, Germany, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany, and; Helmholtz Association / Helmholtz-Zentrum Dresden - Rossendorf (HZDR), Dresden, Germany
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Kristin Stützer
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| |
Collapse
|
4
|
Pastor-Serrano O, Habraken S, Lathouwers D, Hoogeman M, Schaart D, Perkó Z. How should we model and evaluate breathing interplay effects in IMPT? Phys Med Biol 2021; 66. [PMID: 34757958 DOI: 10.1088/1361-6560/ac383f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 11/10/2021] [Indexed: 11/12/2022]
Abstract
Breathing interplay effects in Intensity Modulated Proton Therapy (IMPT) arise from the interaction between target motion and the scanning beam. Assessing the detrimental effect of interplay and the clinical robustness of several mitigation techniques requires statistical evaluation procedures that take into account the variability of breathing during dose delivery. In this study, we present such a statistical method to model intra-fraction respiratory motion based on breathing signals and assess clinical relevant aspects related to the practical evaluation of interplay in IMPT such as how to model irregular breathing, how small breathing changes affect the final dose distribution, and what is the statistical power (number of different scenarios) required for trustworthy quantification of interplay effects. First, two data-driven methodologies to generate artificial patient-specific breathing signals are compared: a simple sinusoidal model, and a precise probabilistic deep learning model generating very realistic samples of patient breathing. Second, we investigate the highly fluctuating relationship between interplay doses and breathing parameters, showing that small changes in breathing period result in large local variations in the dose. Our results indicate that using a limited number of samples to calculate interplay statistics introduces a bigger error than using simple sinusoidal models based on patient parameters or disregarding breathing hysteresis during the evaluation. We illustrate the power of the presented statistical method by analyzing interplay robustness of 4DCT and Internal Target Volume (ITV) treatment plans for a 8 lung cancer patients, showing that, unlike 4DCT plans, even 33 fraction ITV plans systematically fail to fulfill robustness requirements.
Collapse
Affiliation(s)
- Oscar Pastor-Serrano
- Delft University of Technology, Department of Radiation Science and Technology, Delft, The Netherlands
| | - Steven Habraken
- Erasmus MC Cancer Institute, University Medical Center, Department of Radiotherapy, Rotterdam, The Netherlands.,HollandPTC, Department of Radiation Oncology, Delft, The Netherlands
| | - Danny Lathouwers
- Delft University of Technology, Department of Radiation Science and Technology, Delft, The Netherlands
| | - Mischa Hoogeman
- Erasmus MC Cancer Institute, University Medical Center, Department of Radiotherapy, Rotterdam, The Netherlands.,HollandPTC, Department of Radiation Oncology, Delft, The Netherlands
| | - Dennis Schaart
- Delft University of Technology, Department of Radiation Science and Technology, Delft, The Netherlands.,HollandPTC, Department of Radiation Oncology, Delft, The Netherlands
| | - Zoltán Perkó
- Delft University of Technology, Department of Radiation Science and Technology, Delft, The Netherlands
| |
Collapse
|
5
|
Paganetti H, Botas P, Sharp GC, Winey B. Adaptive proton therapy. Phys Med Biol 2021; 66:10.1088/1361-6560/ac344f. [PMID: 34710858 PMCID: PMC8628198 DOI: 10.1088/1361-6560/ac344f] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 10/28/2021] [Indexed: 12/25/2022]
Abstract
Radiation therapy treatments are typically planned based on a single image set, assuming that the patient's anatomy and its position relative to the delivery system remains constant during the course of treatment. Similarly, the prescription dose assumes constant biological dose-response over the treatment course. However, variations can and do occur on multiple time scales. For treatment sites with significant intra-fractional motion, geometric changes happen over seconds or minutes, while biological considerations change over days or weeks. At an intermediate timescale, geometric changes occur between daily treatment fractions. Adaptive radiation therapy is applied to consider changes in patient anatomy during the course of fractionated treatment delivery. While traditionally adaptation has been done off-line with replanning based on new CT images, online treatment adaptation based on on-board imaging has gained momentum in recent years due to advanced imaging techniques combined with treatment delivery systems. Adaptation is particularly important in proton therapy where small changes in patient anatomy can lead to significant dose perturbations due to the dose conformality and finite range of proton beams. This review summarizes the current state-of-the-art of on-line adaptive proton therapy and identifies areas requiring further research.
Collapse
Affiliation(s)
- Harald Paganetti
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Pablo Botas
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
- Foundation 29 of February, Pozuelo de Alarcón, Madrid, Spain
| | - Gregory C Sharp
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Brian Winey
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
6
|
Zheng Y, Jiang S, Yang Z. Deformable registration of chest CT images using a 3D convolutional neural network based on unsupervised learning. J Appl Clin Med Phys 2021; 22:22-35. [PMID: 34505341 PMCID: PMC8504612 DOI: 10.1002/acm2.13392] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 06/10/2021] [Accepted: 07/29/2021] [Indexed: 11/09/2022] Open
Abstract
Purpose The deformable registration of 3D chest computed tomography (CT) images is one of the most important tasks in the field of medical image registration. However, the nonlinear deformation and large‐scale displacement of lung tissues caused by respiratory motion cause great challenges in the deformable registration of 3D lung CT images. Materials and methods We proposed an end‐to‐end fast registration method based on unsupervised learning, optimized the classic U‐Net, and added inception modules between skip connections. The inception module attempts to capture and merge information at different spatial scales to generate a high‐precision dense displacement vector field. To solve the problem of voxel folding in flexible registration, we put the Jacobian regularization term into the loss function to directly penalize the singularity of the displacement field during training to ensure a smooth displacement vector field. In the stage of data preprocessing, we segmented the lung fields to eliminate the interference of irrelevant information in the network during training. The existing publicly available datasets cannot implement model training. To alleviate the problem of overfitting caused by limited data resources being available, we proposed a data augmentation method based on the 3D‐TPS (3D thin plate spline) transform to expand the training data. Results Compared with the experimental results obtained by using the VoxelMorph deep learning method and registration packages, such as ANTs and Elastix, we achieved a competitive target registration error of 2.09 mm, an optimal Dice score of 0.987, and almost no folding voxels. Additionally, the proposed method was much faster than the traditional methods. Conclusions In this study, we have shown that the proposed method was efficient in 3D chest image registration. The promising results demonstrated that our method showed strong robustness in the deformable registration of 3D chest CT images.
Collapse
Affiliation(s)
- Yongnan Zheng
- School of Mechanical Engineering, Tianjin University, Tianjin, China
| | - Shan Jiang
- School of Mechanical Engineering, Tianjin University, Tianjin, China
| | - Zhiyong Yang
- School of Mechanical Engineering, Tianjin University, Tianjin, China
| |
Collapse
|
7
|
Gut P, Krieger M, Lomax T, Weber DC, Hrbacek J. Combining rescanning and gating for a time-efficient treatment of mobile tumors using pencil beam scanning proton therapy. Radiother Oncol 2021; 160:82-89. [PMID: 33839206 DOI: 10.1016/j.radonc.2021.03.041] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 03/04/2021] [Accepted: 03/31/2021] [Indexed: 12/17/2022]
Abstract
BACKGROUND AND PURPOSE Respiratory motion during proton therapy can severely degrade dose distributions, particularly due to interplay effects when using pencil beam scanning. Combined rescanning and gating treatments for moving tumors mitigates dose degradation, but at the cost of increased treatment delivery time. The objective of this study was to identify the time efficiency of these dose degradation-motion mitigation strategies for different range of motions. MATERIALS AND METHODS Seventeen patients with thoracic or abdominal tumors were studied. Tumor motion amplitudes ranged from 2-30 mm. Deliveries using different combinations of rescanning and gating were simulated with a dense dose spot grid (4 × 4 × 2.5 mm3) for all patients and a sparse dose spot grid (8 × 8 × 5 mm3) for six patients with larger tumor movements (>8 mm). The resulting plans were evaluated in terms of CTV coverage and time efficiency. RESULTS Based on the studied patient cohort, it has been shown that for amplitudes up to 5 mm, no motion mitigation is required with a dense spot grid. For amplitudes between 5 and 10 mm, volumetric rescanning should be applied while maintaining a 100% duty cycle when using a dense spot grid. Although gating could be envisaged to reduce the target volume for intermediate motion, it has been shown that the dose to normal tissues would only be reduced marginally. Moreover, the treatment time would increase. Finally, for larger motion amplitudes, both volumetric rescanning and respiratory gating should be applied with both spot grids. In addition, it has been shown that a dense spot grid delivers better CTV dose coverage than a sparse dose grid. CONCLUSION Volumetric rescanning and/or respiratory gating can be used in order to effectively and efficiently mitigate dose degradation due to tumor movement.
Collapse
Affiliation(s)
- Pauline Gut
- Department of Physics, ETH Zurich, Zurich, Switzerland; Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland
| | - Miriam Krieger
- Department of Physics, ETH Zurich, Zurich, Switzerland; Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland
| | - Tony Lomax
- Department of Physics, ETH Zurich, Zurich, Switzerland; Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland
| | - Damien C Weber
- Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland; Department of Radiation Oncology, University Hospital of Zurich, Zurich, Switzerland; Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Switzerland
| | - Jan Hrbacek
- Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland.
| |
Collapse
|
8
|
Wong SL, Alshaikhi J, Grimes H, Amos RA, Poynter A, Rompokos V, Gulliford S, Royle G, Liao Z, Sharma RA, Mendes R. Retrospective Planning Study of Patients with Superior Sulcus Tumours Comparing Pencil Beam Scanning Protons to Volumetric-Modulated Arc Therapy. Clin Oncol (R Coll Radiol) 2021; 33:e118-e131. [PMID: 32798157 PMCID: PMC7883303 DOI: 10.1016/j.clon.2020.07.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/30/2020] [Accepted: 07/22/2020] [Indexed: 12/25/2022]
Abstract
AIMS Twenty per cent of patients with non-small cell lung cancer present with stage III locally advanced disease. Precision radiotherapy with pencil beam scanning (PBS) protons may improve outcomes. However, stage III is a heterogeneous group and accounting for complex tumour motion is challenging. As yet, it remains unclear as to whom will benefit. In our retrospective planning study, we explored if patients with superior sulcus tumours (SSTs) are a select cohort who might benefit from this treatment. MATERIALS AND METHODS Patients with SSTs treated with radical radiotherapy using four-dimensional planning computed tomography between 2010 and 2015 were identified. Tumour motion was assessed and excluded if greater than 5 mm. Photon volumetric-modulated arc therapy (VMAT) and PBS proton single-field optimisation plans, with and without inhomogeneity corrections, were generated retrospectively. Robustness analysis was assessed for VMAT and PBS plans involving: (i) 5 mm geometric uncertainty, with an additional 3.5% range uncertainty for proton plans; (ii) verification plans at maximal inhalation and exhalation. Comparative dosimetric and robustness analyses were carried out. RESULTS Ten patients were suitable. The mean clinical target volume D95 was 98.1% ± 0.4 (97.5-98.8) and 98.4% ± 0.2 (98.1-98.9) for PBS and VMAT plans, respectively. All normal tissue tolerances were achieved. The same four PBS and VMAT plans failed robustness assessment. Inhomogeneity corrections minimally impacted proton plan robustness and made it worse in one case. The most important factor affecting target coverage and robustness was the clinical target volume entering the spinal canal. Proton plans significantly reduced the mean lung dose (by 21.9%), lung V5, V10, V20 (by 47.9%, 36.4%, 12.1%, respectively), mean heart dose (by 21.4%) and thoracic vertebra dose (by 29.2%) (P < 0.05). CONCLUSIONS In this planning study, robust PBS plans were achievable in carefully selected patients. Considerable dose reductions to the lung, heart and thoracic vertebra were possible without compromising target coverage. Sparing these lymphopenia-related organs may be particularly important in this era of immunotherapy.
Collapse
Affiliation(s)
- S-L Wong
- University College London Cancer Institute, London, UK; Department of Clinical Oncology, University College London Hospitals NHS Foundation Trust, London, UK.
| | - J Alshaikhi
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK; Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK; Saudi Particle Therapy Centre, Riyadh, Saudi Arabia
| | - H Grimes
- Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - R A Amos
- Department of Clinical Oncology, University College London Hospitals NHS Foundation Trust, London, UK; Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK; Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - A Poynter
- Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - V Rompokos
- Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - S Gulliford
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK; Department of Radiotherapy Physics, University College London Hospitals NHS Foundation Trust, London, UK
| | - G Royle
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Z Liao
- Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - R A Sharma
- University College London Cancer Institute, London, UK; Department of Clinical Oncology, University College London Hospitals NHS Foundation Trust, London, UK; NIHR University College London Hospitals Biomedical Research Centre, London, UK
| | - R Mendes
- Department of Clinical Oncology, University College London Hospitals NHS Foundation Trust, London, UK
| |
Collapse
|
9
|
Raldow A, Lamb J, Hong T. Proton beam therapy for tumors of the upper abdomen. Br J Radiol 2019; 93:20190226. [PMID: 31430202 DOI: 10.1259/bjr.20190226] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Proton radiotherapy has clear dosimetric advantages over photon radiotherapy. In contrast to photons, which are absorbed exponentially, protons have a finite range dependent on the initial proton energy. Protons therefore do not deposit dose beyond the tumor, resulting in great conformality, and offers the promise of dose escalation to increase tumor control while minimizing toxicity. In this review, we discuss the rationale for using proton radiotherapy in the treatment of upper abdominal tumors-hepatocellular carcinomas, cholangiocarcinomas and pancreatic cancers. We also review the clinical outcomes and technical challenges of using proton radiotherapy for the treatment of these malignancies. Finally, we discuss the ongoing clinical trials implementing proton radiotherapy for the treatment of primary liver and pancreatic tumors.
Collapse
Affiliation(s)
- Ann Raldow
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA
| | - James Lamb
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA
| | - Theodore Hong
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA
| |
Collapse
|
10
|
Boria AJ, Uh J, Pirlepesov F, Stuckey JC, Axente M, Gargone MA, Hua CH. Interplay Effect of Target Motion and Pencil-Beam Scanning in Proton Therapy for Pediatric Patients. Int J Part Ther 2018; 5:1-10. [PMID: 30800718 PMCID: PMC6383772 DOI: 10.14338/ijpt-17-00030.1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Purpose: To investigate the effect of interplay between spot-scanning proton beams and respiration-induced tumor motion on internal target volume coverage for pediatric patients. Materials and Methods: Photon treatments for 10 children with representative tumor motions (1–13 mm superior-inferior) were replanned to simulate single-field uniform dose–optimized proton therapy. Static plans were designed by using average computed tomography (CT) data sets created from 4D CT data to obtain nominal dose distributions. The motion interplay effect was simulated by assigning each spot in the static plan delivery sequence to 1 of 10 respiratory-phase CTs, using the actual patient breathing trace and specifications of a synchrotron-based proton system. Dose distributions for individual phases were deformed onto the space of the average CT and summed to produce the accumulated dose distribution, whose dose-volume histogram was compared with the one from the static plan. Results: Tumor motion had minimal impact on the internal target volume hot spot (D2), which deviated by <3% from the nominal values of the static plans. The cold spot (D98) was also minimally affected, except in 2 patients with diaphragmatic tumor motion exceeding 10 mm. The impact on tumor coverage was more pronounced with respect to the V99 rather than the V95. Decreases of 10% to 49% in the V99 occurred in multiple patients for whom the beam paths traversed the lung-diaphragm interface and were, therefore, more sensitive to respiration-induced changes in the water equivalent path length. Fractionation alone apparently did not mitigate the interplay effect beyond 6 fractions. Conclusion: The interplay effect is not a concern when delivering scanning proton beams to younger pediatric patients with tumors located in the retroperitoneal space and tumor motion of <5 mm. Children and adolescents with diaphragmatic tumor motion exceeding 10 mm require special attention, because significant declines in target coverage and dose homogeneity were seen in simulated treatments of such patients.
Collapse
Affiliation(s)
- Andrew J Boria
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA.,School of Health Sciences, Purdue University, West Lafayette, IN, USA
| | - Jinsoo Uh
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Fakhriddin Pirlepesov
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - James C Stuckey
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA.,Department of Physics, Rhodes College, Memphis, TN, USA
| | - Marian Axente
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Melissa A Gargone
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Chia-Ho Hua
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| |
Collapse
|
11
|
Intensity modulated proton therapy (IMPT) - The future of IMRT for head and neck cancer. Oral Oncol 2018; 88:66-74. [PMID: 30616799 DOI: 10.1016/j.oraloncology.2018.11.015] [Citation(s) in RCA: 93] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Revised: 11/11/2018] [Accepted: 11/12/2018] [Indexed: 12/13/2022]
Abstract
Radiation therapy plays an integral role in the management of head and neck cancers (HNCs). While most HNC patients have historically been treated with photon-based radiation techniques such as intensity modulated radiation therapy (IMRT), there is a growing awareness of the potential clinical benefits of proton therapy over IMRT in the definitive, postoperative and reirradiation settings given the unique physical properties of protons. Intensity modulated proton therapy (IMPT), also known as "pencil beam proton therapy," is a sophisticated mode of proton therapy that is analogous to IMRT and an active area of investigation in cancer care. Multifield optimization IMPT allows for high quality plans that can target superficially located HNCs as well as large neck volumes while significantly reducing integral doses. Several dosimetric studies have demonstrated the superiority of IMPT over IMRT to improve dose sparing of nearby organs such as the larynx, salivary glands, and esophagus. Evidence of the clinical translation of these dosimetric advantages has been demonstrated with documented toxicity reductions (such as decreased feeding tube dependency) after IMPT for patients with HNCs. While there are relative challenges to IMPT planning that exist today such as particle range uncertainties and high sensitivity to anatomical changes, ongoing investigations in image-guidance techniques and robust optimization methods are promising. A systematic approach towards utilizing IMPT and additional prospective studies are necessary in order to more accurately estimate the clinical benefit of IMPT over IMRT and passive proton therapy on a case-by-case basis for patients with sub-site specific HNCs.
Collapse
|
12
|
St James S, Grassberger C, Lu HM. Considerations when treating lung cancer with passive scatter or active scanning proton therapy. Transl Lung Cancer Res 2018; 7:210-215. [PMID: 29876321 DOI: 10.21037/tlcr.2018.04.01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Lung cancer, due to its poor clinical outcomes and significant toxicity associated with standard photon-based radiation, is a disease site that has the potential to greatly benefit from accurate treatment with proton radiation therapy. The potential of proton therapy is the ability to increase the radiation dose to the tumor while simultaneously decreasing the radiation dose to surrounding healthy tissues. For lung cancer treatment, this could mean significant sparing of the uninvolved healthy lung, which is difficult to achieve with external photon beam therapy, or decreasing the heart dose. In treating lung cancer with proton therapy, some additional considerations need to be made compared to treating patients with external photon beam radiation therapy. These include accounting for the finite range of protons in the patient, understanding temporal effects, potential dose discrepancies and choosing an appropriate treatment planning system for the task. One final consideration is differences between the different available proton therapy delivery systems-passive scattered proton therapy (PSPT) and active scanning proton therapy.
Collapse
Affiliation(s)
- Sara St James
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Clemens Grassberger
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Hsiao-Ming Lu
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
13
|
Abstract
Proton therapy is a promising but challenging treatment modality for the management of lung cancer. The technical challenges are due to respiratory motion, low dose tolerance of adjacent normal tissue and tissue density heterogeneity. Different imaging modalities are applied at various steps of lung proton therapy to provide information on target definition, target motion, proton range, patient setup and treatment outcome assessment. Imaging data is used to guide treatment design, treatment delivery, and treatment adaptation to ensure the treatment goal is achieved. This review article will summarize and compare various imaging techniques that can be used in every step of lung proton therapy to address these challenges.
Collapse
Affiliation(s)
- Miao Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Boon-Keng Kevin Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
14
|
Botas P, Grassberger C, Sharp G, Paganetti H. Density overwrites of internal tumor volumes in intensity modulated proton therapy plans for mobile lung tumors. Phys Med Biol 2018; 63:035023. [PMID: 29219119 PMCID: PMC5850956 DOI: 10.1088/1361-6560/aaa035] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The purpose of this study was to investigate internal tumor volume density overwrite strategies to minimize intensity modulated proton therapy (IMPT) plan degradation of mobile lung tumors. Four planning paradigms were compared for nine lung cancer patients. Internal gross tumor volume (IGTV) and internal clinical target volume (ICTV) structures were defined encompassing their respective volumes in every 4DCT phase. The paradigms use different planning CT (pCT) created from the average intensity projection (AIP) of the 4DCT, overwriting the density within the IGTV to account for movement. The density overwrites were: (a) constant filling with 100 HU (C100) or (b) 50 HU (C50), (c) maximum intensity projection (MIP) across phases, and (d) water equivalent path length (WEPL) consideration from beam's-eye-view. Plans were created optimizing dose-influence matrices calculated with fast GPU Monte Carlo (MC) simulations in each pCT. Plans were evaluated with MC on the 4DCTs using a model of the beam delivery time structure. Dose accumulation was performed using deformable image registration. Interplay effect was addressed applying 10 times rescanning. Significantly less DVH metrics degradation occurred when using MIP and WEPL approaches. Target coverage ([Formula: see text] Gy(RBE)) was fulfilled in most cases with MIP and WEPL ([Formula: see text] Gy (RBE)), keeping dose heterogeneity low ([Formula: see text] Gy(RBE)). The mean lung dose was kept lowest by the WEPL strategy, as well as the maximum dose to organs at risk (OARs). The impact on dose levels in the heart, spinal cord and esophagus were patient specific. Overall, the WEPL strategy gives the best performance and should be preferred when using a 3D static geometry for lung cancer IMPT treatment planning. Newly available fast MC methods make it possible to handle long simulations based on 4D data sets to perform studies with high accuracy and efficiency, even prior to individual treatment planning.
Collapse
Affiliation(s)
- Pablo Botas
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, United States of America. University of Heidelberg, Department of Physics, Heidelberg, Germany
| | | | | | | |
Collapse
|
15
|
Tseng YD, Wootton L, Nyflot M, Apisarnthanarax S, Rengan R, Bloch C, Sandison G, St. James S. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion? ACTA ACUST UNITED AC 2018; 63:02NT03. [DOI: 10.1088/1361-6560/aaa44e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
16
|
Vyfhuis MA, Onyeuku N, Diwanji T, Mossahebi S, Amin NP, Badiyan SN, Mohindra P, Simone CB. Advances in proton therapy in lung cancer. Ther Adv Respir Dis 2018; 12:1753466618783878. [PMID: 30014783 PMCID: PMC6050808 DOI: 10.1177/1753466618783878] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Accepted: 05/29/2018] [Indexed: 12/18/2022] Open
Abstract
Lung cancer remains the leading cause of cancer deaths in the United States (US) and worldwide. Radiation therapy is a mainstay in the treatment of locally advanced non-small cell lung cancer (NSCLC) and serves as an excellent alternative for early stage patients who are medically inoperable or who decline surgery. Proton therapy has been shown to offer a significant dosimetric advantage in NSCLC patients over photon therapy, with a decrease in dose to vital organs at risk (OARs) including the heart, lungs and esophagus. This in turn, can lead to a decrease in acute and late toxicities in a population already predisposed to lung and cardiac injury. Here, we present a review on proton treatment techniques, studies, clinical outcomes and toxicities associated with treating both early stage and locally advanced NSCLC.
Collapse
Affiliation(s)
- Melissa A.L. Vyfhuis
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Nasarachi Onyeuku
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Tejan Diwanji
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Sina Mossahebi
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Neha P. Amin
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Shahed N. Badiyan
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Pranshu Mohindra
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, Baltimore, MD, USA
| | - Charles B. Simone
- Maryland Proton Treatment Center, University of
Maryland School of Medicine, 850 West Baltimore Street, Baltimore, MD 21201,
USA
| |
Collapse
|
17
|
Tajiri S, Tashiro M, Mizukami T, Tsukishima C, Torikoshi M, Kanai T. Margin estimation and disturbances of irradiation field in layer-stacking carbon-ion beams for respiratory moving targets. JOURNAL OF RADIATION RESEARCH 2017; 58:840-848. [PMID: 28339740 PMCID: PMC5710598 DOI: 10.1093/jrr/rrx001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 05/30/2016] [Accepted: 01/10/2017] [Indexed: 06/06/2023]
Abstract
Carbon-ion therapy by layer-stacking irradiation for static targets has been practised in clinical treatments. In order to apply this technique to a moving target, disturbances of carbon-ion dose distributions due to respiratory motion have been studied based on the measurement using a respiratory motion phantom, and the margin estimation given by the square root of the summation Internal margin2+Setup margin2 has been assessed. We assessed the volume in which the variation in the ratio of the dose for a target moving due to respiration relative to the dose for a static target was within 5%. The margins were insufficient for use with layer-stacking irradiation of a moving target, and an additional margin was required. The lateral movement of a target converts to the range variation, as the thickness of the range compensator changes with the movement of the target. Although the additional margin changes according to the shape of the ridge filter, dose uniformity of 5% can be achieved for a spherical target 93 mm in diameter when the upward range variation is limited to 5 mm and the additional margin of 2.5 mm is applied in case of our ridge filter. Dose uniformity in a clinical target largely depends on the shape of the mini-peak as well as on the bolus shape. We have shown the relationship between range variation and dose uniformity. In actual therapy, the upper limit of target movement should be considered by assessing the bolus shape.
Collapse
Affiliation(s)
- Shinya Tajiri
- Department of Heavy Ion Beam Medical Physics and Biology, Gunma University Graduate School of Medicine, 3-39-22 Showa-Machi, Maebashi, Gunma 371-8511, Japan
- Mitsubishi Electric Corporation, 1-1-2, Wadasaki-cho, Hyogo-ku, Kobe 652-8555, Japan
| | - Mutsumi Tashiro
- Research Program for Heavy Ion Therapy, Gunma University Initiative for Advanced Research, 3-39-22 Showa-Machi, Maebashi, Gunma, Japan
- Gunma University Heavy Ion Medical Center, 3-39-22 Showa-Machi, Maebashi, Gunma, Japan
| | - Tomohiro Mizukami
- Mitsubishi Electric Corporation, 1-1-2, Wadasaki-cho, Hyogo-ku, Kobe 652-8555, Japan
| | - Chihiro Tsukishima
- Mitsubishi Electric Corporation, 1-1-2, Wadasaki-cho, Hyogo-ku, Kobe 652-8555, Japan
| | - Masami Torikoshi
- Department of Heavy Ion Beam Medical Physics and Biology, Gunma University Graduate School of Medicine, 3-39-22 Showa-Machi, Maebashi, Gunma 371-8511, Japan
- Gunma University Heavy Ion Medical Center, 3-39-22 Showa-Machi, Maebashi, Gunma, Japan
| | - Tatsuaki Kanai
- Department of Heavy Ion Beam Medical Physics and Biology, Gunma University Graduate School of Medicine, 3-39-22 Showa-Machi, Maebashi, Gunma 371-8511, Japan
- Gunma University Heavy Ion Medical Center, 3-39-22 Showa-Machi, Maebashi, Gunma, Japan
| |
Collapse
|
18
|
Knecht ML, Wang N, Vassantachart A, Mifflin R, Slater JD, Yang GY. Individualized 4-dimensional computed tomography proton treatment for pancreatic tumors. J Gastrointest Oncol 2017; 8:675-682. [PMID: 28890818 DOI: 10.21037/jgo.2016.12.10] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND The goal of this study is to determine whether a phase or reconstruction of a 10-phase 4 dimensional computed tomography (4D CT) scan can be used as the primary planning scan for proton treatment of the pancreas, thus eliminating the need for second a slow CT or free breathing CT. METHODS Ten patients with pancreatic adenocarcinoma were simulated with 4D CT and a proton treatment plan generated based upon one of three primary planning scans, the T0 phase, T50 phase or average reconstruction. These plans were then exported to each of the remaining phases of the 4D CT and the dose to 95% of the target (D95) calculated. Plans were deemed adequate if the D95 remained at 99% of the prescribed dose or greater. RESULTS For the ten patients in this study anterior abdominal motion was found to range from 2-27 mm (mean 7.50±6.79 mm). For 9 of 10 patients the anterior abdominal motion was ≤8 mm and all three primary planning scans provided adequate target coverage, resulting in minimum D95 coverage per plan of T0_plan 99.7%, T50_plan 99.3% and AVE_plan 99%. However no plan provided adequate target coverage on the single patient with the largest anterior abdominal motion, 27 mm, and cranio-caudal motion, 20 mm, with minimum D95 values of T0_plan 96.3%, T50_plan 68%, and AVE_plan 68%. CONCLUSIONS The primary plans tested based up on the T0, T50 and average reconstructions provided adequate D95 coverage throughout the respiratory cycle as long as the anterior abdominal motion was ≤8 mm and can be considered for use as the primary proton planning scan.
Collapse
Affiliation(s)
- Matthew L Knecht
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University Medical Center, Loma Linda, CA, USA
| | - Ning Wang
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University Medical Center, Loma Linda, CA, USA
| | - April Vassantachart
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University Medical Center, Loma Linda, CA, USA
| | - Rachel Mifflin
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University Medical Center, Loma Linda, CA, USA
| | - Jerry D Slater
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University Medical Center, Loma Linda, CA, USA
| | - Gary Y Yang
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University Medical Center, Loma Linda, CA, USA
| |
Collapse
|
19
|
Szeto YZ, Witte MG, van Herk M, Sonke JJ. A population based statistical model for daily geometric variations in the thorax. Radiother Oncol 2017; 123:99-105. [DOI: 10.1016/j.radonc.2017.02.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Revised: 01/09/2017] [Accepted: 02/08/2017] [Indexed: 11/27/2022]
|
20
|
Intrafractional dose variation and beam configuration in carbon ion radiotherapy for esophageal cancer. Radiat Oncol 2016; 11:150. [PMID: 27846916 PMCID: PMC5109696 DOI: 10.1186/s13014-016-0727-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Accepted: 11/09/2016] [Indexed: 12/04/2022] Open
Abstract
Background In carbon ion radiotherapy (CIR) for esophageal cancer, organ and target motion is a major challenge for treatment planning due to potential range deviations. This study intends to analyze the impact of intrafractional variations on dosimetric parameters and to identify favourable settings for robust treatment plans. Methods We contoured esophageal boost volumes in different organ localizations for four patients and calculated CIR-plans with 13 different beam geometries on a free-breathing CT. Forward calculation of these plans was performed on 4D-CT datasets representing seven different phases of the breathing cycle. Plan quality was assessed for each patient and beam configuration. Results Target volume coverage was adequate for all settings in the baseline CIR-plans (V95 > 98% for two-beam geometries, > 94% for one-beam geometries), but reduced on 4D-CT plans (V95 range 50–95%). Sparing of the organs at risk (OAR) was adequate, but range deviations during the breathing cycle partly caused critical, maximum doses to spinal cord up to 3.5x higher than expected. There was at least one beam configuration for each patient with appropriate plan quality. Conclusions Despite intrafractional motion, CIR for esophageal cancer is possible with robust treatment plans when an individually optimized beam setup is selected depending on tumor size and localization.
Collapse
|
21
|
Szeto YZ, Witte MG, van Kranen SR, Sonke JJ, Belderbos J, van Herk M. Effects of anatomical changes on pencil beam scanning proton plans in locally advanced NSCLC patients. Radiother Oncol 2016; 120:286-92. [PMID: 27393217 DOI: 10.1016/j.radonc.2016.04.002] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Revised: 04/02/2016] [Accepted: 04/03/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND AND PURPOSE Daily anatomical variations can cause considerable differences between delivered and planned dose. This study simulates and evaluates these effects in spot-scanning proton therapy for lung cancer patients. MATERIALS AND METHODS Robust intensity modulated treatment plans were designed on the mid-position CT scan for sixteen locally advanced lung cancer patients. To estimate dosimetric uncertainty, deformable registration was performed on their daily CBCTs to generate 4DCT equivalent scans for each fraction and to map recomputed dose to a common frame. RESULTS Without adaptive planning, eight patients had an undercoverage of the targets of more than 2GyE (maximum of 14.1GyE) on the recalculated treatment dose from the daily anatomy variations including respiration. In organs at risk, a maximum increase of 4.7GyE in the D1 was found in the mediastinal structures. The effect of respiratory motion alone is smaller: 1.4GyE undercoverage for targets and less than 1GyE for organs at risk. CONCLUSIONS Daily anatomical variations over the course of treatment can cause considerable dose differences in the robust planned dose distribution. An advanced planning strategy including knowledge of anatomical uncertainties would be recommended to improve plan robustness against interfractional variations. For large anatomical changes, adaptive therapy is mandatory.
Collapse
Affiliation(s)
- Yenny Z Szeto
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Marnix G Witte
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Simon R van Kranen
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - José Belderbos
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Marcel van Herk
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| |
Collapse
|
22
|
Dueck J, Knopf AC, Lomax A, Albertini F, Persson GF, Josipovic M, Aznar M, Weber DC, Munck af Rosenschöld P. Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy. Int J Radiat Oncol Biol Phys 2016; 95:534-541. [DOI: 10.1016/j.ijrobp.2015.11.015] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Revised: 11/04/2015] [Accepted: 11/09/2015] [Indexed: 12/25/2022]
|
23
|
Chang JY, Jabbour SK, De Ruysscher D, Schild SE, Simone CB, Rengan R, Feigenberg S, Khan AJ, Choi NC, Bradley JD, Zhu XR, Lomax AJ, Hoppe BS. Consensus Statement on Proton Therapy in Early-Stage and Locally Advanced Non-Small Cell Lung Cancer. Int J Radiat Oncol Biol Phys 2016; 95:505-516. [PMID: 27084663 PMCID: PMC10868643 DOI: 10.1016/j.ijrobp.2016.01.036] [Citation(s) in RCA: 112] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Revised: 12/08/2015] [Accepted: 01/19/2016] [Indexed: 12/25/2022]
Abstract
Radiation dose escalation has been shown to improve local control and survival in patients with non-small cell lung cancer in some studies, but randomized data have not supported this premise, possibly owing to adverse effects. Because of the physical characteristics of the Bragg peak, proton therapy (PT) delivers minimal exit dose distal to the target volume, resulting in better sparing of normal tissues in comparison to photon-based radiation therapy. This is particularly important for lung cancer given the proximity of the lung, heart, esophagus, major airways, large blood vessels, and spinal cord. However, PT is associated with more uncertainty because of the finite range of the proton beam and motion for thoracic cancers. PT is more costly than traditional photon therapy but may reduce side effects and toxicity-related hospitalization, which has its own associated cost. The cost of PT is decreasing over time because of reduced prices for the building, machine, maintenance, and overhead, as well as newer, shorter treatment programs. PT is improving rapidly as more research is performed particularly with the implementation of 4-dimensional computed tomography-based motion management and intensity modulated PT. Given these controversies, there is much debate in the oncology community about which patients with lung cancer benefit significantly from PT. The Particle Therapy Co-operative Group (PTCOG) Thoracic Subcommittee task group intends to address the issues of PT indications, advantages and limitations, cost-effectiveness, technology improvement, clinical trials, and future research directions. This consensus report can be used to guide clinical practice and indications for PT, insurance approval, and clinical or translational research directions.
Collapse
Affiliation(s)
- Joe Y Chang
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas.
| | - Salma K Jabbour
- Rutgers Cancer Institute of New Jersey Rutgers, Robert Wood Johnson Medical School, The State University of New Jersey, New Brunswick, New Jersey
| | | | | | - Charles B Simone
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Ramesh Rengan
- University of Washington Medical Center, Seattle, Washington
| | | | - Atif J Khan
- Rutgers Cancer Institute of New Jersey Rutgers, Robert Wood Johnson Medical School, The State University of New Jersey, New Brunswick, New Jersey
| | - Noah C Choi
- Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | | | - Xiaorong R Zhu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | | | - Bradford S Hoppe
- University of Florida Proton Therapy Institute, Jacksonville, Florida
| |
Collapse
|
24
|
Scalco E, Schwarz M, Sutto M, Ravanelli D, Fellin F, Cattaneo GM, Rizzo G. Evaluation of different CT lung anatomies for proton therapy with pencil beam scanning delivery, using a validated non-rigid image registration method. Acta Oncol 2016; 55:647-51. [PMID: 26586265 DOI: 10.3109/0284186x.2015.1105383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Elisa Scalco
- Istituto di Bioimmagini e Fisiologia Molecolare (IBFM), CNR, Segrate (MI), Italy
| | - Marco Schwarz
- Centro di Protonterapia, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | | | - Daniele Ravanelli
- Centro di Protonterapia, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | - Francesco Fellin
- Centro di Protonterapia, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | | | - Giovanna Rizzo
- Istituto di Bioimmagini e Fisiologia Molecolare (IBFM), CNR, Segrate (MI), Italy
| |
Collapse
|
25
|
Matney JE, Park PC, Li H, Court LE, Zhu XR, Dong L, Liu W, Mohan R. Perturbation of water-equivalent thickness as a surrogate for respiratory motion in proton therapy. J Appl Clin Med Phys 2016; 17:368-378. [PMID: 27074459 PMCID: PMC5546214 DOI: 10.1120/jacmp.v17i2.5795] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 12/02/2015] [Accepted: 11/18/2015] [Indexed: 12/25/2022] Open
Abstract
Respiratory motion is traditionally assessed using tumor motion magnitude. In proton therapy, respiratory motion causes density variations along the beam path that result in uncertainties of proton range. This work has investigated the use of water‐equivalent thickness (WET) to quantitatively assess the effects of respiratory motion on calculated dose in passively scattered proton therapy (PSPT). A cohort of 29 locally advanced non‐small cell lung cancer patients treated with 87 PSPT treatment fields were selected for analysis. The variation in WET (ΔWET) along each field was calculated between exhale and inhale phases of the simulation four‐dimensional computed tomography. The change in calculated dose (ΔDose) between full‐inhale and full‐exhale phase was quantified for each field using dose differences, 3D gamma analysis, and differential area under the curve (ΔAUC) analysis. Pearson correlation coefficients were calculated between ΔDose and ΔWET. Three PSPT plans were redesigned using field angles to minimize variations in ΔWET and compared to the original plans. The median ΔWET over 87 treatment fields ranged from 1‐9 mm, while the ΔWET 95th percentile value ranged up to 42 mm. The ΔWET was significantly correlated (p<0.001) to the ΔDose for all metrics analyzed. The patient plans that were redesigned using ΔWET analysis to select field angles were more robust to the effects of respiratory motion, as ΔAUC values were reduced by more than 60% in all three cases. The tumor motion magnitude alone does not capture the potential dosimetric error due to respiratory motion because the proton range is sensitive to the motion of all patient anatomy. The use of ΔWET has been demonstrated to identify situations where respiratory motion can impact the calculated dose. Angular analysis of ΔWET may be capable of designing radiotherapy plans that are more robust to the effects of respiratory motion. PACS number(s): 87.55.‐x
Collapse
|
26
|
Brevet R, Richter D, Graeff C, Durante M, Bert C. Treatment Parameters Optimization to Compensate for Interfractional Anatomy Variability and Intrafractional Tumor Motion. Front Oncol 2015; 5:291. [PMID: 26734573 PMCID: PMC4689810 DOI: 10.3389/fonc.2015.00291] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Accepted: 12/07/2015] [Indexed: 11/13/2022] Open
Abstract
Scanned ion beam therapy of lung tumors is severely limited in its clinical applicability by intrafractional organ motion, interference effects between beam and tumor motion (interplay), as well as interfractional anatomic changes. To compensate for dose deterioration caused by intrafractional motion, motion mitigation techniques, such as gating, have been developed. However, optimization of the treatment parameters is needed to further improve target dose coverage and normal tissue sparing. The aim of this study was to determine treatment-planning parameters that permit to recover good target coverage for each fraction of lung tumor treatments. For 9 lung tumor patients from MD Anderson Cancer Center (Houston, Texas), a total of 70 weekly time-resolved computed tomography (4DCT) datasets, which depict the evolution of the patient anatomy over the several fractions of the treatment, were available. Using the GSI in-house treatment planning system TRiP4D, 4D simulations were performed on each weekly 4DCT for each patient using gating and optimization of a single treatment plan based on a planning CT acquired prior to treatment. The impact on target dose coverage (V 95%,CTV) of variations in focus size and length of the gating window, as well as different additional margins and the number of fields was analyzed. It appeared that interfractional variability could potentially have a larger impact on V 95%,CTV than intrafractional motion. However, among the investigated parameters, the use of a large beam spot size, a short gating window, additional margins, and multiple fields permitted to obtain an average V 95%,CTV of 96.5%. In the presented study, it was shown that optimized treatment parameters have an important impact on target dose coverage in the treatment of moving tumors. Indeed, intrafractional motion occurring during the treatment of lung tumors and interfractional variability were best mitigated using a large focus, a short gating window, additional margins, and three fields.
Collapse
Affiliation(s)
- Romain Brevet
- GSI Helmholtzzentrum für Schwerionenforschung , Darmstadt , Germany
| | - Daniel Richter
- FAU Erlangen-Nürnberg and Universitätsklinikum Erlangen , Erlangen , Germany
| | - Christian Graeff
- GSI Helmholtzzentrum für Schwerionenforschung , Darmstadt , Germany
| | - Marco Durante
- GSI Helmholtzzentrum für Schwerionenforschung , Darmstadt , Germany
| | - Christoph Bert
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany; FAU Erlangen-Nürnberg and Universitätsklinikum Erlangen, Erlangen, Germany
| |
Collapse
|
27
|
Deep Inspiration Breath Hold-Based Radiation Therapy: A Clinical Review. Int J Radiat Oncol Biol Phys 2015; 94:478-92. [PMID: 26867877 DOI: 10.1016/j.ijrobp.2015.11.049] [Citation(s) in RCA: 159] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 11/03/2015] [Accepted: 11/29/2015] [Indexed: 01/06/2023]
Abstract
Several recent developments in linear accelerator-based radiation therapy (RT) such as fast multileaf collimators, accelerated intensity modulation paradigms like volumeric modulated arc therapy and flattening filter-free (FFF) high-dose-rate therapy have dramatically shortened the duration of treatment fractions. Deliverable photon dose distributions have approached physical complexity limits as a consequence of precise dose calculation algorithms and online 3-dimensional image guided patient positioning (image guided RT). Simultaneously, beam quality and treatment speed have continuously been improved in particle beam therapy, especially for scanned particle beams. Applying complex treatment plans with steep dose gradients requires strategies to mitigate and compensate for motion effects in general, particularly breathing motion. Intrafractional breathing-related motion results in uncertainties in dose delivery and thus in target coverage. As a consequence, generous margins have been used, which, in turn, increases exposure to organs at risk. Particle therapy, particularly with scanned beams, poses additional problems such as interplay effects and range uncertainties. Among advanced strategies to compensate breathing motion such as beam gating and tracking, deep inspiration breath hold (DIBH) gating is particularly advantageous in several respects, not only for hypofractionated, high single-dose stereotactic body RT of lung, liver, and upper abdominal lesions but also for normofractionated treatment of thoracic tumors such as lung cancer, mediastinal lymphomas, and breast cancer. This review provides an in-depth discussion of the rationale and technical implementation of DIBH gating for hypofractionated and normofractionated RT of intrathoracic and upper abdominal tumors in photon and proton RT.
Collapse
|
28
|
Mayer R, Liacouras P, Thomas A, Kang M, Lin L, Simone CB. 3D printer generated thorax phantom with mobile tumor for radiation dosimetry. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:074301. [PMID: 26233396 DOI: 10.1063/1.4923294] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This article describes the design, construction, and properties of an anthropomorphic thorax phantom with a moving surrogate tumor. This novel phantom permits detection of dose both inside and outside a moving tumor and within the substitute lung tissue material. A 3D printer generated the thorax shell composed of a chest wall, spinal column, and posterior regions of the phantom. Images of a computed tomography scan of the thorax from a patient with lung cancer provided the template for the 3D printing. The plastic phantom is segmented into two materials representing the muscle and bones, and its geometry closely matches a patient. A surrogate spherical plastic tumor controlled by a 3D linear stage simulates a lung tumor's trajectory during normal breathing. Sawdust emulates the lung tissue in terms of average and distribution in Hounsfield numbers. The sawdust also provides a forgiving medium that permits tumor motion and sandwiching of radiochromic film inside the mobile surrogate plastic tumor for dosimetry. A custom cork casing shields the film and tumor and eliminates film bending during extended scans. The phantom, lung tissue surrogate, and radiochromic film are exposed to a seven field plan based on an ECLIPSE plan for 6 MV photons from a Trilogy machine delivering 230 cGy to the isocenter. The dose collected in a sagittal plane is compared to the calculated plan. Gamma analysis finds 8.8% and 5.5% gamma failure rates for measurements of large amplitude trajectory and static measurements relative to the large amplitude plan, respectively. These particular gamma analysis results were achieved using parameters of 3% dose and 3 mm, for regions receiving doses >150 cGy. The plan assumes a stationary detection grid unlike the moving radiochromic film and tissues. This difference was experimentally observed and motivated calculated dose distributions that incorporated the phase of the tumor periodic motion. These calculations modestly improve agreement between the measured and intended doses.
Collapse
Affiliation(s)
- Rulon Mayer
- Henry Jackson Foundation, Bethesda, Maryland 20817, USA
| | - Peter Liacouras
- Walter Reed National Military Medical Center, Bethesda, Maryland 20899, USA
| | - Andrew Thomas
- ATC Healthcare, Washington, District of Columbia 20006, USA
| | - Minglei Kang
- Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | - Liyong Lin
- Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | - Charles B Simone
- Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| |
Collapse
|
29
|
Tumour Movement in Proton Therapy: Solutions and Remaining Questions: A Review. Cancers (Basel) 2015; 7:1143-53. [PMID: 26132317 PMCID: PMC4586762 DOI: 10.3390/cancers7030829] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2015] [Revised: 06/10/2015] [Accepted: 06/18/2015] [Indexed: 12/25/2022] Open
Abstract
Movement of tumours, mostly by respiration, has been a major problem for treating lung cancer, liver tumours and other locations in the abdomen and thorax. Organ motion is indeed one component of geometrical uncertainties that includes delineation and target definition uncertainties, microscopic disease and setup errors. At present, minimising motion seems to be the easiest to implement in clinical practice. If combined with adaptive approaches to correct for gradual anatomical variations, it may be a practical strategy. Other approaches such as repainting and tracking could increase the accuracy of proton therapy delivery, but advanced 4D solutions are needed. Moreover, there is a need to perform clinical studies to investigate which approach is the best in a given clinical situation. The good news is that existing and emerging technology and treatment planning systems as will without doubt lead in the forthcoming future to practical solutions to tackle intra-fraction motion in proton therapy. These developments may also improve motion management in photon therapy as well.
Collapse
|
30
|
Abstract
Intensity modulated proton therapy (IMPT) implies the electromagnetic spatial control of well-circumscribed "pencil beams" of protons of variable energy and intensity. Proton pencil beams take advantage of the charged-particle Bragg peak-the characteristic peak of dose at the end of range-combined with the modulation of pencil beam variables to create target-local modulations in dose that achieves the dose objectives. IMPT improves on X-ray intensity modulated beams (intensity modulated radiotherapy or volumetric modulated arc therapy) with dose modulation along the beam axis as well as lateral, in-field, dose modulation. The clinical practice of IMPT further improves the healthy tissue vs target dose differential in comparison with X-rays and thus allows increased target dose with dose reduction elsewhere. In addition, heavy-charged-particle beams allow for the modulation of biological effects, which is of active interest in combination with dose "painting" within a target. The clinical utilization of IMPT is actively pursued but technical, physical and clinical questions remain. Technical questions pertain to control processes for manipulating pencil beams from the creation of the proton beam to delivery within the patient within the accuracy requirement. Physical questions pertain to the interplay between the proton penetration and variations between planned and actual patient anatomical representation and the intrinsic uncertainty in tissue stopping powers (the measure of energy loss per unit distance). Clinical questions remain concerning the impact and management of the technical and physical questions within the context of the daily treatment delivery, the clinical benefit of IMPT and the biological response differential compared with X-rays against which clinical benefit will be judged. It is expected that IMPT will replace other modes of proton field delivery. Proton radiotherapy, since its first practice 50 years ago, always required the highest level of accuracy and pioneered volumetric treatment planning and imaging at a level of quality now standard in X-ray therapy. IMPT requires not only the highest precision tools but also the highest level of system integration of the services required to deliver high-precision radiotherapy.
Collapse
Affiliation(s)
- H M Kooy
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - C Grassberger
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
31
|
Rana S, Simpson H, Larson G, Zheng Y. Dosimetric impact of number of treatment fields in uniform scanning proton therapy planning of lung cancer. J Med Phys 2014; 39:212-8. [PMID: 25525308 PMCID: PMC4258728 DOI: 10.4103/0971-6203.144483] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 10/06/2014] [Accepted: 10/12/2014] [Indexed: 12/28/2022] Open
Abstract
The main purpose of this study was to perform a treatment planning study for lung cancer comparing 2-field (2F) versus 3-field (3F) techniques in uniform scanning proton therapy (USPT). Ten clinically approved lung cancer treatment plans delivered using USPT at our proton center were included in this retrospective study. All 10 lung cases included 4D computed tomography (CT) simulation. The delineation of target volumes was done based on the maximum intensity projection (MIP) images. Both the 3F and 2F treatment plans were generated for the total dose of 74 cobalt-gray-equivalent (CGE) with a daily dose of 2 CGE. 3F plan was generated by adding an extra beam in the 2F plan. Various dosimetric parameters between 2F and 3F plans were evaluated. 3F plans produced better target coverage and conformality as well as lower mean dose to the lung, with absolute difference between 3F and 2F plans within 2%. In contrast, the addition of third beam led to increase of low-dose regions (V20 and V5) in the lung in 3F plans compared to the ones in 2F plans with absolute difference within 2%. Maximum dose to the spinal cord was lower in 2F plans. Mean dose to the heart and esophagus were comparable in both 3F and 2F plans. In conclusion, the 3F technique in USPT produced better target coverage and conformality, but increased the low-dose regions in the lung when compared to 2F technique.
Collapse
Affiliation(s)
- Suresh Rana
- Department of Medical Physics, ProCure Proton Therapy Center, Oklahoma City, Oklahoma, USA
| | - Hilarie Simpson
- Department of Medical Dosimetry, ProCure Proton Therapy Center, Oklahoma City, Oklahoma, USA
| | - Gary Larson
- Department of Radiation Oncology, ProCure Proton Therapy Center, Oklahoma City, Oklahoma, USA
| | - Yuanshui Zheng
- Department of Medical Physics, ProCure Proton Therapy Center, Oklahoma City, Oklahoma, USA
| |
Collapse
|
32
|
Bert C, Graeff C, Riboldi M, Nill S, Baroni G, Knopf AC. Advances in 4D treatment planning for scanned particle beam therapy - report of dedicated workshops. Technol Cancer Res Treat 2014; 13:485-95. [PMID: 24354749 PMCID: PMC4527425 DOI: 10.7785/tcrtexpress.2013.600274] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 09/27/2013] [Accepted: 10/01/2013] [Indexed: 11/25/2022] Open
Abstract
We report on recent progress in the field of mobile tumor treatment with scanned particle beams, as discussed in the latest editions of the 4D treatment planning workshop. The workshop series started in 2009, with about 20 people from 4 research institutes involved, all actively working on particle therapy delivery and development. The first workshop resulted in a summary of recommendations for the treatment of mobile targets, along with a list of requirements to apply these guidelines clinically. The increased interest in the treatment of mobile tumors led to a continuously growing number of attendees: the 2012 edition counted more than 60 participants from 20 institutions and commercial vendors. The focus of research discussions among workshop participants progressively moved from 4D treatment planning to complete 4D treatments, aiming at effective and safe treatment delivery. Current research perspectives on 4D treatments include all critical aspects of time resolved delivery, such as in-room imaging, motion detection, beam application, and quality assurance techniques. This was motivated by the start of first clinical treatments of hepato cellular tumors with a scanned particle beam, relying on gating or abdominal compression for motion mitigation. Up to date research activities emphasize significant efforts in investigating advanced motion mitigation techniques, with a specific interest in the development of dedicated tools for experimental validation. Potential improvements will be made possible in the near future through 4D optimized treatment plans that require upgrades of the currently established therapy control systems for time resolved delivery. But since also these novel optimization techniques rely on the validity of the 4DCT, research focusing on alternative 4D imaging technique, such as MRI based 4DCT generation will continue.
Collapse
Affiliation(s)
- Christoph Bert
- University Clinic Erlangen, Radiation Oncology, Universitatsstrasse 27, 91054 Erlangen, Germany.
| | | | | | | | | | | |
Collapse
|
33
|
Wink KCJ, Roelofs E, Solberg T, Lin L, Simone CB, Jakobi A, Richter C, Lambin P, Troost EGC. Particle therapy for non-small cell lung tumors: where do we stand? A systematic review of the literature. Front Oncol 2014; 4:292. [PMID: 25401087 PMCID: PMC4212620 DOI: 10.3389/fonc.2014.00292] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Accepted: 10/07/2014] [Indexed: 12/25/2022] Open
Abstract
This review article provides a systematic overview of the currently available evidence on the clinical effectiveness of particle therapy for the treatment of non-small cell lung cancer and summarizes findings of in silico comparative planning studies. Furthermore, technical issues and dosimetric uncertainties with respect to thoracic particle therapy are discussed.
Collapse
Affiliation(s)
- Krista C J Wink
- Department of Radiation Oncology (MAASTRO Clinic), GROW - School for Oncology and Developmental Biology, Maastricht University Medical Centre , Maastricht , Netherlands
| | - Erik Roelofs
- Department of Radiation Oncology (MAASTRO Clinic), GROW - School for Oncology and Developmental Biology, Maastricht University Medical Centre , Maastricht , Netherlands
| | - Timothy Solberg
- Department of Radiation Oncology, Hospital of the University of Pennsylvania , Philadelphia, PA , USA
| | - Liyong Lin
- Department of Radiation Oncology, Hospital of the University of Pennsylvania , Philadelphia, PA , USA
| | - Charles B Simone
- Department of Radiation Oncology, Hospital of the University of Pennsylvania , Philadelphia, PA , USA
| | - Annika Jakobi
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden and Helmholtz-Zentrum Dresden-Rossendorf , Dresden , Germany
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden and Helmholtz-Zentrum Dresden-Rossendorf , Dresden , Germany ; German Cancer Consortium (DKTK) Dresden and German Cancer Research Center (DKFZ) , Heidelberg , Germany
| | - Philippe Lambin
- Department of Radiation Oncology (MAASTRO Clinic), GROW - School for Oncology and Developmental Biology, Maastricht University Medical Centre , Maastricht , Netherlands
| | - Esther G C Troost
- Department of Radiation Oncology (MAASTRO Clinic), GROW - School for Oncology and Developmental Biology, Maastricht University Medical Centre , Maastricht , Netherlands
| |
Collapse
|
34
|
Li Y, Kardar L, Li X, Li H, Cao W, Chang JY, Liao L, Zhu RX, Sahoo N, Gillin M, Liao Z, Komaki R, Cox JD, Lim G, Zhang X. On the interplay effects with proton scanning beams in stage III lung cancer. Med Phys 2014; 41:021721. [PMID: 24506612 DOI: 10.1118/1.4862076] [Citation(s) in RCA: 80] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. METHODS Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. RESULTS Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. CONCLUSIONS Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.
Collapse
Affiliation(s)
- Yupeng Li
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Applied Research, Varian Medical Systems, Palo Alto, California 94304
| | - Laleh Kardar
- Department of Industrial Engineering, The University of Houston, Houston, Texas 77204
| | - Xiaoqiang Li
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Heng Li
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Wenhua Cao
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Department of Industrial Engineering, The University of Houston, Houston, Texas 77204
| | - Joe Y Chang
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Li Liao
- Department of Industrial Engineering, The University of Houston, Houston, Texas 77204
| | - Ronald X Zhu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Narayan Sahoo
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Michael Gillin
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Zhongxing Liao
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Ritsuko Komaki
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - James D Cox
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - Gino Lim
- Department of Industrial Engineering, The University of Houston, Houston, Texas 77204
| | - Xiaodong Zhang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| |
Collapse
|
35
|
Mori S, Inaniwa T, Miki K, Shirai T, Noda K. Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system. Br J Radiol 2014; 87:20140233. [PMID: 25168286 DOI: 10.1259/bjr.20140233] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE Treatment planning for charged particle therapy in the thoracic and abdominal regions should take account of range uncertainty due to intrafractional motion. Here, we developed a design tool (4Dtool) for the target volume [field-specific target volume (FTV)], which accounts for this uncertainty using four-dimensional CT (4DCT). METHODS Target and normal tissue contours were input manually into a treatment planning system (TPS). These data were transferred to the 4Dtool via the picture archiving and communication system (PACS). Contours at the reference phase were propagated to other phases by deformable image registration. FTV was calculated using 4DCT on the 4Dtool. The TPS displays FTV contours using digital imaging and communications in medicine files imported from the PACS. These treatment parameters on the CT image at the reference phase were then used for dose calculation on the TPS. The tool was tested in single clinical case randomly selected from patients treated at our centre for lung cancer. RESULTS In this clinical case, calculation of dose distribution with the 4Dtool resulted in the successful delivery of carbon-ion beam at the reference phase of 95% of the prescribed dose to the clinical target volume (CTV). Application to the other phases also provided sufficient dose to the CTV. CONCLUSION The 4Dtool software allows the design of the target volume with consideration to intrafractional range variation and is now in routine clinical use at our institution. ADVANCES IN KNOWLEDGE Our alternative technique represents a practical approach to four-dimensional treatment planning within the current state of charged particle therapy.
Collapse
Affiliation(s)
- S Mori
- Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba, Japan
| | | | | | | | | |
Collapse
|
36
|
Phillips J, Gueorguiev G, Shackleford JA, Grassberger C, Dowdell S, Paganetti H, Sharp GC. Computing proton dose to irregularly moving targets. Phys Med Biol 2014; 59:4261-73. [PMID: 25029239 DOI: 10.1088/0031-9155/59/15/4261] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE While four-dimensional computed tomography (4DCT) and deformable registration can be used to assess the dose delivered to regularly moving targets, there are few methods available for irregularly moving targets. 4DCT captures an idealized waveform, but human respiration during treatment is characterized by gradual baseline shifts and other deviations from a periodic signal. This paper describes a method for computing the dose delivered to irregularly moving targets based on 1D or 3D waveforms captured at the time of delivery. METHODS The procedure uses CT or 4DCT images for dose calculation, and 1D or 3D respiratory waveforms of the target position at time of delivery. Dose volumes are converted from their Cartesian geometry into a beam-specific radiological depth space, parameterized in 2D by the beam aperture, and longitudinally by the radiological depth. In this new frame of reference, the proton doses are translated according to the motion found in the 1D or 3D trajectory. These translated dose volumes are weighted and summed, then transformed back into Cartesian space, yielding an estimate of the dose that includes the effect of the measured breathing motion. The method was validated using a synthetic lung phantom and a single representative patient CT. Simulated 4DCT was generated for the phantom with 2 cm peak-to-peak motion. RESULTS A passively-scattered proton treatment plan was generated using 6 mm and 5 mm smearing for the phantom and patient plans, respectively. The method was tested without motion, and with two simulated breathing signals: a 2 cm amplitude sinusoid, and a 2 cm amplitude sinusoid with 3 cm linear drift in the phantom. The tumor positions were equally weighted for the patient calculation. Motion-corrected dose was computed based on the mid-ventilation CT image in the phantom and the peak exhale position in the patient. Gamma evaluation was 97.8% without motion, 95.7% for 2 cm sinusoidal motion, 95.7% with 3 cm drift in the phantom (2 mm, 2%), and 90.8% (3 mm, 3%)for the patient data. CONCLUSIONS We have demonstrated a method for accurately reproducing proton dose to an irregularly moving target from a single CT image. We believe this algorithm could prove a useful tool to study the dosimetric impact of baseline shifts either before or during treatment.
Collapse
Affiliation(s)
- Justin Phillips
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | | | | | | | | | | | | |
Collapse
|
37
|
Schätti A, Zakova M, Meer D, Lomax AJ. The effectiveness of combined gating and re-scanning for treating mobile targets with proton spot scanning. An experimental and simulation-based investigation. Phys Med Biol 2014; 59:3813-28. [PMID: 24955723 DOI: 10.1088/0031-9155/59/14/3813] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Organ motion is one of the major obstacles in radiotherapy and charged particle therapy. Even more so, the theoretical advantages of dose distributions in scanned ion beam therapy may be lost due to the interplay between organ motion and beam scanning. Several techniques for dealing with this problem have been devised. In re-scanning, the target volume is scanned several times to average out the motion effects. In gating and breath-hold, dose is only delivered if the tumour is in a narrow window of position. Experiments have been performed to verify if gating and re-scanning are effective means of motion mitigation. Dose distributions were acquired in a lateral plane of a homogeneous phantom. For a spherical target volume and regular motion gating was sufficient. However, for realistic, irregular motion or a patient target volume, gating did not reduce the interplay effect to an acceptable level. Combining gating with re-scanning recovered the dose distributions. The simplest re-scanning approach, where a treatment plan is duplicated several times and applied in sequence, was not efficient. Simulations of different combinations of gating window sizes and re-scanning schemes revealed that reducing the gating window is the most efficient approach. However, very small gating windows are not robust for irregular motion.
Collapse
Affiliation(s)
- A Schätti
- Centre for Proton Therapy, Paul Scherrer Institut, Villigen, Switzerland
| | | | | | | |
Collapse
|
38
|
Chi A, Nguyen NP, Welsh JS, Tse W, Monga M, Oduntan O, Almubarak M, Rogers J, Remick SC, Gius D. Strategies of dose escalation in the treatment of locally advanced non-small cell lung cancer: image guidance and beyond. Front Oncol 2014; 4:156. [PMID: 24999451 PMCID: PMC4064255 DOI: 10.3389/fonc.2014.00156] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Accepted: 06/04/2014] [Indexed: 12/25/2022] Open
Abstract
Radiation dose in the setting of chemo-radiation for locally advanced non-small cell lung cancer (NSCLC) has been historically limited by the risk of normal tissue toxicity and this has been hypothesized to correlate with the poor results in regard to local tumor recurrences. Dose escalation, as a means to improve local control, with concurrent chemotherapy has been shown to be feasible with three-dimensional conformal radiotherapy in early phase studies with good clinical outcome. However, the potential superiority of moderate dose escalation to 74 Gy has not been shown in phase III randomized studies. In this review, the limitations in target volume definition in previous studies; and the factors that may be critical to safe dose escalation in the treatment of locally advanced NSCLC, such as respiratory motion management, image guidance, intensity modulation, FDG-positron emission tomography incorporation in the treatment planning process, and adaptive radiotherapy, are discussed. These factors, along with novel treatment approaches that have emerged in recent years, are proposed to warrant further investigation in future trials in a more comprehensive and integrated fashion.
Collapse
Affiliation(s)
- Alexander Chi
- Department of Radiation Oncology, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - Nam Phong Nguyen
- The International Geriatric Radiotherapy Group , Tucson, AZ , USA
| | - James S Welsh
- Northern Illinois University Institute for Neutron Therapy at Fermilab , Batavia, IL , USA
| | - William Tse
- Division of Hematology and Oncology, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - Manish Monga
- Division of Hematology and Oncology, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - Olusola Oduntan
- Thoracic Surgery, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - Mohammed Almubarak
- Division of Hematology and Oncology, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - John Rogers
- Division of Hematology and Oncology, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - Scot C Remick
- Division of Hematology and Oncology, Mary Babb Randolph Cancer Center of West Virginia University , Morgantown, WV , USA
| | - David Gius
- Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center of Northwestern University , Chicago, IL , USA
| |
Collapse
|
39
|
Grassberger C, Daartz J, Dowdell S, Ruggieri T, Sharp G, Paganetti H. Quantification of proton dose calculation accuracy in the lung. Int J Radiat Oncol Biol Phys 2014; 89:424-30. [PMID: 24726289 DOI: 10.1016/j.ijrobp.2014.02.023] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 02/06/2014] [Accepted: 02/14/2014] [Indexed: 11/19/2022]
Abstract
PURPOSE To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)-based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung. METHODS AND MATERIALS A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung, and to determine the distal fall-off of the proton beam. Results were compared with TPS and MC calculations. Dose distributions in 19 patients (54 fields total) were simulated using MC and compared to the TPS algorithm. RESULTS MC increased dose calculation accuracy in lung tissue compared with the TPS and reproduced dose measurements in the target to within ±2%. The average difference between measured and predicted dose in a plane through the center of the target was 5.6% for the TPS and 1.6% for MC. MC recalculations in patients showed a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. For large tumors, MC also predicted consistently higher V5 and V10 to the normal lung, because of a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target could show large deviations, although this effect was highly patient specific. Range measurements showed that MC can reduce range uncertainty by a factor of ~2: the average (maximum) difference to the measured range was 3.9 mm (7.5 mm) for MC and 7 mm (17 mm) for the TPS in lung tissue. CONCLUSION Integration of Monte Carlo dose calculation techniques into the clinic would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. In addition, the ability to confidently reduce range margins would benefit all patients by potentially lowering toxicity.
Collapse
Affiliation(s)
- Clemens Grassberger
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts; Center for Proton Radiotherapy, Paul Scherrer Institute, Villigen, Switzerland.
| | - Juliane Daartz
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Stephen Dowdell
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Thomas Ruggieri
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Greg Sharp
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
40
|
Chang JY, Cox JD. Proton Therapy. Lung Cancer 2014. [DOI: 10.1002/9781118468791.ch22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
41
|
Richter D, Schwarzkopf A, Trautmann J, Krämer M, Durante M, Jäkel O, Bert C. Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy. Med Phys 2013; 40:051722. [PMID: 23635270 DOI: 10.1118/1.4800802] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused by patient motion and dynamic beam delivery. METHODS The 4DTPS integrates data interfaces to 4D computed tomography (4DCT), deformable image registration and clinically used motion monitoring devices. The authors implemented a novel data model for 4D image segmentation using Boolean mask volume datasets and developed an algorithm propagating a manually contoured reference contour dataset to all 4DCT phases. They further included detailed treatment simulation and dose reconstruction functionality, based on the irregular patient motion and the temporal structure of the beam delivery. The treatment simulation functionality was validated against experimental data from irradiation of moving radiographic films in air, 3D moving ionization chambers in a water phantom, and moving cells in a biological phantom with a scanned carbon ion beam. The performance of the program was compared to results obtained with predecessor programs. RESULTS The measured optical density distributions of the radiographic films were reproduced by the simulations to (-2 ± 12)%. Compared to earlier versions of the 4DTPS, the mean agreement improved by 2%, standard deviations were reduced by 7%. The simulated dose to the moving ionization chambers in water showed an agreement with the measured dose of (-1 ± 4)% for the typical beam configuration. The mean deviation of the simulated from the measured biologically effective dose determined via cell survival was (617 ± 538) mGy relative biological effectiveness corresponding to (10 ± 9)%. CONCLUSIONS The authors developed a research 4DTPS suitable for realistic treatment planning on patient data and capable of simulating dose delivery to a moving patient geometry for scanned ion beams. The accuracy and reliability of treatment simulations improved considerably with respect to earlier versions of the 4DTPS.
Collapse
Affiliation(s)
- D Richter
- GSI Helmholtzzentrum für Schwerionenforschung GmbH, Abt. Biophysik, Planckstraße 1, 64291 Darmstadt, Germany
| | | | | | | | | | | | | |
Collapse
|
42
|
Schätti A, Zakova M, Meer D, Lomax AJ. Experimental verification of motion mitigation of discrete proton spot scanning by re-scanning. Phys Med Biol 2013; 58:8555-72. [DOI: 10.1088/0031-9155/58/23/8555] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
43
|
Petit S, Seco J, Kooy H. Increasing maximum tumor dose to manage range uncertainties in IMPT treatment planning. Phys Med Biol 2013; 58:7329-41. [PMID: 24077105 DOI: 10.1088/0031-9155/58/20/7329] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The accuracy of intensity modulated proton therapy (IMPT) is sensitive to range uncertainties. Geometric margins, as dosimetric surrogates, are ineffective and robust optimization strategies are needed. These, however, lead to increased normal tissue dose. We explore here how this dose increase can be reduced by increasing the maximum tumor dose instead. We focus on range uncertainties, modeled by scaling the stopping powers 5% up (undershoot) or down (overshoot) compared to the nominal scenario. Robust optimization optimizes for target dose conformity in the most likely scenario, not the worst, while constraining target coverage for the worst-case scenario. Non-robust plans are also generated. Different maximum target doses are applied (105% versus 120% versus 140%) to investigate the effect on normal tissue dose reduction. The method is tested on a homogeneous and a lung phantom and on a liver patient. Target D99 of the robust plans equals the prescription dose of 60 GyE for all scenarios, but decreases to 36 GyE for the non-robust plans. The mean normal tissue dose in a 2 cm ring around the target is 11% to 31% higher for the robust plans. This increase can be reduced to -8% and 3% (compared to the non-robust plan) by allowing a maximum tumor dose of 120% instead of 105%. Thus robustness leads to more normal tissue dose, but it can be compensated by allowing a higher maximum tumor dose.
Collapse
Affiliation(s)
- Steven Petit
- Department of Radiation Oncology, Daniel Den Hoed Cancer Center, Erasmus MC, Rotterdam, The Netherlands
| | | | | |
Collapse
|
44
|
Knopf AC, Boye D, Lomax A, Mori S. Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion. Phys Med Biol 2013; 58:6079-94. [DOI: 10.1088/0031-9155/58/17/6079] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
45
|
Gomez DR, Gillin M, Liao Z, Wei C, Lin SH, Swanick C, Alvarado T, Komaki R, Cox JD, Chang JY. Phase 1 study of dose escalation in hypofractionated proton beam therapy for non-small cell lung cancer. Int J Radiat Oncol Biol Phys 2013; 86:665-70. [PMID: 23688815 PMCID: PMC3926094 DOI: 10.1016/j.ijrobp.2013.03.035] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Revised: 03/26/2013] [Accepted: 03/30/2013] [Indexed: 12/25/2022]
Abstract
BACKGROUND Many patients with locally advanced non-small cell lung cancer (NSCLC) cannot undergo concurrent chemotherapy because of comorbidities or poor performance status. Hypofractionated radiation regimens, if tolerable, may provide an option to these patients for effective local control. METHODS AND MATERIALS Twenty-five patients were enrolled in a phase 1 dose-escalation trial of proton beam therapy (PBT) from September 2010 through July 2012. Eligible patients had histologically documented lung cancer, thymic tumors, carcinoid tumors, or metastatic thyroid tumors. Concurrent chemotherapy was not allowed, but concurrent treatment with biologic agents was. The dose-escalation schema comprised 15 fractions of 3 Gy(relative biological effectiveness [RBE])/fraction, 3.5 Gy(RBE)/fraction, or 4 Gy(RBE)/fraction. Dose constraints were derived from biologically equivalent doses of standard fractionated treatment. RESULTS The median follow-up time for patients alive at the time of analysis was 13 months (range, 8-28 months). Fifteen patients received treatment to hilar or mediastinal lymph nodes. Two patients experienced dose-limiting toxicity possibly related to treatment; 1 received 3.5-Gy(RBE) fractions and experienced an in-field tracheoesophageal fistula 9 months after PBT and 1 month after bevacizumab. The other patient received 4-Gy(RBE) fractions and was hospitalized for bacterial pneumonia/radiation pneumonitis 4 months after PBT. CONCLUSION Hypofractionated PBT to the thorax delivered over 3 weeks was well tolerated even with significant doses to the lungs and mediastinal structures. Phase 2/3 trials are needed to compare the efficacy of this technique with standard treatment for locally advanced NSCLC.
Collapse
Affiliation(s)
- Daniel R Gomez
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Selek U, Chang JY. Evolution of modern-era radiotherapy strategies for unresectable advanced non-small-cell lung cancer. Lung Cancer Manag 2013. [DOI: 10.2217/lmt.13.14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
SUMMARY In patients with advanced non-small-cell lung cancer, the current standard of care is chemoradiotherapy, which offers better outcomes than sequential treatments. Conventional radiotherapy (60–66 Gy) is associated with poor local control and dismal survival. The challenge is to escalate and/or accelerate the radiation dose safely and effectively. Cutting-edge technologies, such as 4D image-based motion management, intensity-modulated radiation therapy, proton therapy and image-guided radiotherapy, have enabled the delivery of higher doses of radiation to the difficult-to-treat moving tumors with lower toxicity risks. Incorporating the motion in 4D planning, such as an average internal target volume, would enable radiation oncologists to integrate the interfractional anatomic changes in the course of treatment for proper estimation of the actual dose delivery. Optimizing the combination of systemic therapy with radiotherapy, using a personalized approach based on using cutting-edge technologies for knowledge-guided dose escalation/acceleration radiotherapy, are crucial to improving the therapeutic ratio of non-small-cell lung cancer.
Collapse
Affiliation(s)
- Ugur Selek
- The MD Anderson Radiation Treatment Center at American Hospital, Istanbul, 34365, Turkey
- Koc University, School of Medicine, Istanbul, 34450, Turkey
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Joe Y Chang
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| |
Collapse
|
47
|
Tashiro M, Ishii T, Koya JI, Okada R, Kurosawa Y, Arai K, Abe S, Ohashi Y, Shimada H, Yusa K, Kanai T, Yamada S, Kawamura H, Ebara T, Ohno T, Nakano T. Technical approach to individualized respiratory-gated carbon-ion therapy for mobile organs. Radiol Phys Technol 2013; 6:356-66. [PMID: 23568337 PMCID: PMC3709089 DOI: 10.1007/s12194-013-0208-3] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2012] [Revised: 03/14/2013] [Accepted: 03/15/2013] [Indexed: 12/25/2022]
Abstract
We propose a strategy of individualized image acquisitions and treatment planning for respiratory-gated carbon-ion therapy. We implemented it in clinical treatments for diseases of mobile organs such as lung cancers at the Gunma University Heavy Ion Medical Center in June 2010. Gated computed tomography (CT) scans were used for treatment planning, and four-dimensional (4D) CT scans were used to evaluate motion errors within the gating window to help define the internal margins (IMs) and planning target volume for each patient. The smearing technique or internal gross tumor volume (IGTV = GTV + IM), where the stopping power ratio was replaced with the tumor value, was used for range compensation of moving targets. Dose distributions were obtained using the gated CT images for the treatment plans. The influence of respiratory motion on the dose distribution was verified with the planned beam settings using 4D CT images at some phases within the gating window before the adoption of the plan. A total of 14 lung cancer patients were treated in the first year. The planned margins with the proposed method were verified with clinical X-ray set-up images by deriving setup and internal motion errors. The planned margins were considered to be reasonable compared with the errors, except for large errors observed in some cases.
Collapse
Affiliation(s)
- Mutsumi Tashiro
- Gunma University Heavy Ion Medical Center, 3-39-22 Showa-machi, Maebashi, Gunma 371-8511, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Wang N, Patyal B, Ghebremedhin A, Bush D. Evaluation and comparison of New 4DCT based strategies for proton treatment planning for lung tumors. Radiat Oncol 2013; 8:73. [PMID: 23531301 PMCID: PMC3652762 DOI: 10.1186/1748-717x-8-73] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Accepted: 03/18/2013] [Indexed: 11/21/2022] Open
Abstract
Purpose To evaluate different strategies for proton lung treatment planning based on four-dimensional CT (4DCT) scans. Methods and Materials Twelve cases, involving only gross tumor volumes (GTV), were evaluated. Single image sets of (1) maximum intensity projection (MIP3) of end inhale (EI), middle exhale (ME) and end exhale (EE) images; (2) average intensity projection (AVG) of all phase images; and (3) EE images from 4DCT scans were selected as primary images for proton treatment planning. Internal target volumes (ITVs) outlined by a clinician were imported into MIP3, AVG, and EE images as planning targets. Initially, treatment uncertainties were not included in planning. Each plan was imported into phase images of 4DCT scans. Relative volumes of GTVs covered by 95% of prescribed dose and mean ipsilateral lung dose of a phase image obtained by averaging the dose in inspiration and expiration phases were used to evaluate the quality of a plan for a particular case. For comparing different planning strategies, the mean of the averaged relative volumes of GTVs covered by 95% of prescribed dose and its standard deviation for each planning strategy for all cases were used. Then, treatment uncertainties were included in planning. Each plan was recalculated in phase images of 4DCT scans. Same strategies were used for plan evaluation except dose-volume histograms of the planning target volumes (PTVs) instead of GTVs were used and the mean and standard deviation of the relative volumes of PTVs covered by 95% of prescribed dose and the ipsilateral lung dose were used to compare different planning strategies. Results MIP3 plans without treatment uncertainties yielded 96.7% of the mean relative GTV covered by 95% of prescribed dose (standard deviations of 5.7% for all cases). With treatment uncertainties, MIP3 plans yielded 99.5% of mean relative PTV covered by 95% of prescribed dose (standard deviations of 0.7%). Inclusion of treatment uncertainties improved PTV dose coverage but also increased the ipsilateral mean lung dose in general, and reduced the variations of the PTV dose coverage among different cases. Plans based on conventional axial CT scan (CVCT) gave the poorest PTV dose coverage (about 96% of mean relative PTV covered by 95% isodose) compared to MIP3 and EE plans, which resulted in 100% of PTV covered by 95% isodose for tumors with relatively large motion. AVG plans demonstrated PTV dose coverage of 89.8% and 94.4% for cases with small tumors. MIP3 plans demonstrated superior tumor coverage and were least sensitive to tumor size and tumor location. Conclusion MIP3 plans based on 4DCT scans were the best planning strategy for proton lung treatment planning.
Collapse
Affiliation(s)
- Ning Wang
- Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, CA 92354, USA.
| | | | | | | |
Collapse
|
49
|
Jeong H, Lee SB, Yoo SH, Lim YK, Kim TH, Park S, Chai GY, Kang KM, Shin D. Compensation method for respiratory motion in proton treatment planning for mobile liver cancer. J Appl Clin Med Phys 2013; 14:4055. [PMID: 23470935 PMCID: PMC5714365 DOI: 10.1120/jacmp.v14i2.4055] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2012] [Revised: 08/29/2012] [Accepted: 08/28/2012] [Indexed: 11/23/2022] Open
Abstract
We evaluated the dosimetric effect of a respiration motion, and sought an effective planning strategy to compensate the motion using four-dimensional computed tomography (4D CT) dataset of seven selected liver patients. For each patient, we constructed four different proton plans based on: (1) average (AVG) CT, (2) maximum-intensity projection (MIP) CT, (3) AVG CT with density override of tumor volume (OVR), and (4) AVG CT with field-specific proton margin which was determined by the range difference between AVG and MIP plans (mAVG). The overall effectiveness of each planning strategy was evaluated by calculating the cumulative dose distribution over an entire breathing cycle. We observed clear differences between AVG and MIP CT-based plans, with significant underdosages at expiratory and inspiratory phases, respectively. Only the mAVG planning strategy was fully successful as the field-specific proton margin applied in the planning strategy complemented both the limitations of AVG and MIP CT-based strategies. These results demonstrated that respiration motion induced significant changes in dose distribution of 3D proton plans for mobile liver cancer and the changes can be effectively compensated by applying field-specific proton margin to each proton field.
Collapse
Affiliation(s)
- Hojin Jeong
- Department of Radiation OncologyInstitute of Health Science, Gyeongsang National University HospitalJinJuKorea
| | - Se Byeong Lee
- Proton Therapy Center, Research Institute and HospitalNational Cancer CenterGoyangKorea
| | - Seung Hoon Yoo
- Department of Radiation OncologyCha Bundang Medical Center, Cha UniversitySeongnamKorea
| | - Young Kyung Lim
- Proton Therapy Center, Research Institute and HospitalNational Cancer CenterGoyangKorea
| | - Tae Hyun Kim
- Proton Therapy Center, Research Institute and HospitalNational Cancer CenterGoyangKorea
| | - Seyjoon Park
- Proton Therapy Center, Research Institute and HospitalNational Cancer CenterGoyangKorea
| | - Gyu Young Chai
- Department of Radiation OncologyInstitute of Health Science, Gyeongsang National University HospitalJinJuKorea
| | - Ki Mun Kang
- Department of Radiation OncologyInstitute of Health Science, Gyeongsang National University HospitalJinJuKorea
| | - Dongho Shin
- Proton Therapy Center, Research Institute and HospitalNational Cancer CenterGoyangKorea
| |
Collapse
|
50
|
Mori S, Zenklusen S, Knopf AC. Current status and future prospects of multi-dimensional image-guided particle therapy. Radiol Phys Technol 2013; 6:249-72. [DOI: 10.1007/s12194-013-0199-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Revised: 01/21/2013] [Accepted: 01/22/2013] [Indexed: 12/25/2022]
|