1
|
Zou W, Dong L, Kevin Teo BK. Current State of Image Guidance in Radiation Oncology: Implications for PTV Margin Expansion and Adaptive Therapy. Semin Radiat Oncol 2018; 28:238-247. [PMID: 29933883 DOI: 10.1016/j.semradonc.2018.02.008] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Image guidance technology has evolved and seen widespread application in the past several decades. Advancements in the diagnostic imaging field have found new applications in radiation oncology and promoted the development of therapeutic devices with advanced imaging capabilities. A recent example is the development of linear accelerators that offer magnetic resonance imaging for real-time imaging and online adaptive planning. Volumetric imaging, in particular, offers more precise localization of soft tissue targets and critical organs which reduces setup uncertainty and permit the use of smaller setup margins. We present a review of the status of current imaging modalities available for radiation oncology and its impact on target margins and use for adaptive therapy.
Collapse
Affiliation(s)
- Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA.
| | - Lei Dong
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| | - Boon-Keng Kevin Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
2
|
Vanhanen A, Syrén H, Kapanen M. Localization accuracy of two electromagnetic tracking systems in prostate cancer radiotherapy: A comparison with fiducial marker based kilovoltage imaging. Phys Med 2018; 56:10-18. [PMID: 30527084 DOI: 10.1016/j.ejmp.2018.11.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Revised: 10/02/2018] [Accepted: 11/10/2018] [Indexed: 10/27/2022] Open
Abstract
The aim of this study was to evaluate the localization accuracy of electromagnetic (EM) tracking systems RayPilot (Micropos Medical AB) and Calypso (Varian Medical Systems) in prostate cancer radiotherapy. The accuracy was assessed by comparing couch shifts obtained with the EM methods to the couch shifts determined by simultaneous fiducial marker (FM) based orthogonal kilovoltage (kV) imaging. Agreement between the methods was compared using Bland-Altman analysis. Interfractional positional stability of the FMs, RayPilot transmitters and Calypso transponders was investigated. 582 fractions from 22 RayPilot patients and 335 fractions from 26 Calypso patients were analyzed. Mean (± standard deviation (SD)) differences between RayPilot and kV imaging were 0.3 ± 2.2, -2.2 ± 2.4 and -0.0 ± 1.0 mm in anterior-posterior (AP), superior-inferior (SI) and left-right (LR) directions, respectively. Corresponding 95% limits of agreement (LOA) were ±4.3, ±4.7 and ±2.1 mm around the mean. Mean (±SD) differences between Calypso and kV imaging were -0.2 ± 0.6, 0.1 ± 0.5 and -0.1 ± 0.4 mm in AP, SI and LR directions, respectively, and corresponding LOAs were ±1.3, ±1.0 and ±0.8 mm around the mean. FMs and transponders were stable: SD of intermarker and intertransponder distances was 0.5 mm. Transmitters were unstable: mean caudal transmitter shift of 1.8 ± 2.0 mm was observed. Results indicate that the localization accuracy of the Calypso is comparable to kV imaging of fiducials and the methods could be used interchangeably. The localization accuracy of the RayPilot is affected by transmitter instability and the positioning of the patient should be verified by other setup techniques. The study is part of clinical trial NCT02319239.
Collapse
Affiliation(s)
- A Vanhanen
- Department of Oncology, Unit of Radiotherapy, Tampere University Hospital, POB-2000, 33521 Tampere, Finland; Department of Medical Physics, Medical Imaging Center, Tampere University Hospital, POB-2000, 33521 Tampere, Finland.
| | - H Syrén
- Micropos Medical AB, Gothenburg, Sweden
| | - M Kapanen
- Department of Oncology, Unit of Radiotherapy, Tampere University Hospital, POB-2000, 33521 Tampere, Finland; Department of Medical Physics, Medical Imaging Center, Tampere University Hospital, POB-2000, 33521 Tampere, Finland
| |
Collapse
|
3
|
Molitoris JK, Diwanji T, Snider JW, Mossahebi S, Samanta S, Badiyan SN, Simone CB, Mohindra P. Advances in the use of motion management and image guidance in radiation therapy treatment for lung cancer. J Thorac Dis 2018; 10:S2437-S2450. [PMID: 30206490 PMCID: PMC6123191 DOI: 10.21037/jtd.2018.01.155] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2018] [Accepted: 01/26/2018] [Indexed: 12/22/2022]
Abstract
The development of advanced radiation technologies, including intensity-modulated radiation therapy (IMRT), stereotactic body radiation therapy (SBRT) and proton therapy, has resulted in increasingly conformal radiation treatments. Recent evidence for the importance of minimizing dose to normal critical structures including the heart and lungs has led to incorporation of these advanced treatment modalities into radiation therapy (RT) for non-small cell lung cancer (NSCLC). While such technologies have allowed for improved dose delivery, implementation requires improved target accuracy with treatments, placing increasing importance on evaluating tumor motion at the time of planning and verifying tumor position at the time of treatment. In this review article, we describe issues and updates related both to motion management and image guidance in the treatment of NSCLC.
Collapse
Affiliation(s)
- Jason K. Molitoris
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Tejan Diwanji
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - James W. Snider
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
- Department of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland, Baltimore, MD, USA
| | - Sina Mossahebi
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
- Department of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland, Baltimore, MD, USA
| | - Santanu Samanta
- Department of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland, Baltimore, MD, USA
| | - Shahed N. Badiyan
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
- Department of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland, Baltimore, MD, USA
| | - Charles B. Simone
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
- Department of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland, Baltimore, MD, USA
| | - Pranshu Mohindra
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
- Department of Radiation Oncology, Maryland Proton Treatment Center, University of Maryland, Baltimore, MD, USA
| |
Collapse
|
4
|
Litzenberg DW, Muenz DG, Archer PG, Jackson WC, Hamstra DA, Hearn JW, Schipper MJ, Spratt DE. Changes in prostate orientation due to removal of a Foley catheter. Med Phys 2018; 45:1369-1378. [PMID: 29474748 DOI: 10.1002/mp.12830] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 01/31/2018] [Accepted: 01/31/2018] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Investigate the impact on prostate orientation caused by use and removal of a Foley catheter, and the dosimetric impact on men prospectively treated with prostate stereotactic body radiotherapy (SBRT). METHODS Twenty-two men underwent a CT simulation with a Foley in place (FCT), followed immediately by a second treatment planning simulation without the Foley (TPCT). The change in prostate orientation was determined by rigid registration of three implanted transponders between FCT and TPCT and compared to measured orientation changes during treatment. The impact on treatment planning and delivery was investigated by analyzing the measured rotations during treatment relative to both CT scans, and introducing rotations of ±15° in the treatment plan to determine the maximum impact of allowed rotations. RESULTS Removing the Foley caused a statistically significant prostate rotation (P < 0.0028) compared to normal biological motion in 60% of patients. The largest change in rotation due to removing a Foley occurs about the left-right axis (tilt) which has a standard deviation two to five times larger than changes in rotation about the Sup-Inf (roll) and Ant-Post (yaw) axes. The change in tilt due to removing a Foley for prone and supine patients was -1.1° ± 6.0° and 0.3° ± 7.4°, showing no strong directional bias. The average tilt during treatment was -1.6° ± 7.1° compared to the TPCT and would have been -2.0° ± 7.1° had the FCT been used as the reference. The TPCT was a better or equivalent representation of prostate tilt in 82% of patients, vs 50% had the FCT been used for treatment planning. However, 92.7% of fractions would still have been within the ±15° rotation limit if only the FCT were used for treatment planning. When rotated ±15°, urethra V105% = 38.85Gy < 20% was exceeded in 27% of the instances, and prostate (CTV) coverage was maintained above D95% > 37 Gy in all but one instance. CONCLUSIONS Removing a Foley catheter can cause large prostate rotations. There does not appear to be a clear dosimetric benefit to obtaining the CT scan with a Foley catheter to define the urethra given the changes in urethral position from removing the Foley catheter. If urethral sparing is desired without the use of a Foley, utilization of an MRI to define the urethra may be necessary, or a pseudo-urethral planning organ at risk volume (PRV) may be used to limit dosimetric hot spots.
Collapse
Affiliation(s)
- Dale W Litzenberg
- Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109-5010, USA
| | - Daniel G Muenz
- Department of Biostatistics, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Paul G Archer
- Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109-5010, USA
| | - William C Jackson
- Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109-5010, USA
| | - Daniel A Hamstra
- Radiation Oncology, Beaumont Health System, Royal Oak, MI, 48073, USA
| | - Jason W Hearn
- Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109-5010, USA
| | - Matthew J Schipper
- Departments of Radiation Oncology and Biostatistics, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Daniel E Spratt
- Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109-5010, USA
| |
Collapse
|
5
|
Janssen N, Eppenga R, Peeters MJV, van Duijnhoven F, Oldenburg H, van der Hage J, Rutgers E, Sonke JJ, Kuhlmann K, Ruers T, Nijkamp J. Real-time wireless tumor tracking during breast conserving surgery. Int J Comput Assist Radiol Surg 2017; 13:531-539. [PMID: 29134472 DOI: 10.1007/s11548-017-1684-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Accepted: 10/30/2017] [Indexed: 12/12/2022]
Abstract
PURPOSE To evaluate a novel surgical navigation system for breast conserving surgery (BCS), based on real-time tumor tracking using the Calypso[Formula: see text] 4D Localization System (Varian Medical Systems Inc., USA). Navigation-guided breast conserving surgery (Nav-BCS) was compared to conventional iodine seed-guided BCS ([Formula: see text]I-BCS). METHODS Two breast phantom types were produced, containing spherical and complex tumors in which wireless transponders (Nav-BCS) or a iodine seed ([Formula: see text]I-BCS) were implanted. For navigation, orthogonal views and 3D volume renders of a CT of the phantom were shown, including a tumor segmentation and a predetermined resection margin. In the same views, a surgical pointer was tracked and visualized. [Formula: see text]I-BCS was performed according to standard protocol. Five surgical breast oncologists first performed a practice session with Nav-BCS, followed by two Nav-BCS and [Formula: see text]I-BCS sessions on spherical and complex tumors. Postoperative CT images of all resection specimens were registered to the preoperative CT. Main outcome measures were the minimum resection margin (in mm) and the excision times. RESULTS The rate of incomplete tumor resections was 6.7% for Nav-BCS and 20% for [Formula: see text]I-BCS. The minimum resection margins on the spherical tumors were 3.0 ± 1.4 mm for Nav-BCS and 2.5 ± 1.6 mm for [Formula: see text]I-BCS (p = 0.63). For the complex tumors, these were 2.2 ± 1.1 mm (Nav-BCS) and 0.9 ± 2.4 mm ([Formula: see text]I-BCS) (p = 0.32). Mean excision times on spherical and complex tumors were 9.5 ± 2.7 min and 9.4 ± 2.6 min (Nav-BCS), compared to 5.8 ± 2.2 min and 4.7 ± 3.4 min ([Formula: see text]I-BCS, both (p < 0.05). CONCLUSIONS The presented surgical navigation system improved the intra-operative awareness about tumor position and orientation, with the potential to improve surgical outcomes for non-palpable breast tumors. Results are positive, and participating surgeons were enthusiastic, but extended surgical experience on real breast tissue is required.
Collapse
Affiliation(s)
- Natasja Janssen
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Roeland Eppenga
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | | | | - Hester Oldenburg
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jos van der Hage
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Emiel Rutgers
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Koert Kuhlmann
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Theo Ruers
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.,Nanobiophysics Group, MIRA Institute, University of Twente, Enschede, The Netherlands
| | - Jasper Nijkamp
- Department of Surgical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| |
Collapse
|
6
|
James J, Cetnar A, Dunlap NE, Huffaker C, Nguyen VN, Potts M, Wang B. Technical Note: Validation and implementation of a wireless transponder tracking system for gated stereotactic ablative radiotherapy of the liver. Med Phys 2017; 43:2794-2801. [PMID: 27277027 DOI: 10.1118/1.4948669] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Tracking soft-tissue targets has recently been cleared as a new application of Calypso, an electromagnetic wireless transponder tracking system, allowing for gated treatment of the liver based on the motion of the target volume itself. The purpose of this study is to describe the details of validating the Calypso system for wireless transponder tracking of the liver and to present the clinical workflow for using it to deliver gated stereotactic ablative radiotherapy (SABR). METHODS A commercial 3D diode array motion system was used to evaluate the dynamic tracking accuracy of Calypso when tracking continuous large amplitude motion. It was then used to perform end-to-end tests to evaluate the dosimetric accuracy of gated beam delivery for liver SABR. In addition, gating limits were investigated to determine how large the gating window can be while still maintaining dosimetric accuracy. The gating latency of the Calypso system was also measured using a customized motion phantom. RESULTS The average absolute difference between the measured and expected positional offset was 0.3 mm. The 2%/2 mm gamma pass rates for the gated treatment delivery were greater than 97%. When increasing the gating limits beyond the known extent of planned motion, the gamma pass rates decreased as expected. The 2%/2 mm gamma pass rate for a 1, 2, and 3 mm increase in gating limits was measured to be 97.8%, 82.9%, and 61.4%, respectively. The average gating latency was measured to be 63.8 ms for beam-hold and 195.8 ms for beam-on. Four liver patients with 17 total fractions have been successfully treated at our institution. CONCLUSIONS Wireless transponder tracking was validated as a dosimetrically accurate way to provide gated SABR of the liver. The dynamic tracking accuracy of the Calypso system met manufacturer's specification, even for continuous large amplitude motion that can be encountered when tracking liver tumors close to the diaphragm. The measured beam-hold gating latency was appropriate for targets that will traverse the gating limit each respiratory cycle causing the beam to be interrupted constantly throughout treatment delivery.
Collapse
Affiliation(s)
- Joshua James
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| | - Ashley Cetnar
- Department of Radiation Oncology, Ohio State University, Columbus, Ohio 43210
| | - Neal E Dunlap
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| | | | - Vi Nhan Nguyen
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| | - Melissa Potts
- Department of Radiology, University of Louisville, Louisville, Kentucky 40202
| | - Brian Wang
- Department of Radiation Oncology, University of Louisville, Louisville, Kentucky 40202
| |
Collapse
|
7
|
Calypso’s array attenuation. JOURNAL OF RADIOTHERAPY IN PRACTICE 2015. [DOI: 10.1017/s1460396915000114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractIntroductionThe Calypso 4D Localization System gives the possibility to track the tumour during treatment, with no additional ionising radiation delivered. To monitor the patient continuously an array is positioned above the patient during the treatment. We intend to study, for various gantry angles, the attenuation effect of the array for 6- and 10 MV and flattening filter free (FFF) 6- and FFF 10 MV photon beams.Materials and methodsMeasurements were performed using an ion chamber placed in a slab phantom positioned at the linac isocenter for 6 MV, 10 MV, FFF 6 MV and FFF 10 MV photon beams. Measurements were performed with and without array above the phantom for 0°, 10°, 20°, 40° and 50° beam angle for a True Beam STx linac, for 5×5 and 10×10 and 15×15 cm2 field size beams to evaluate the attenuation of the array. A VMAT treatment plan was measured using an ArcCheck with and without the array in the beam path.Results and discussionAttenuation measured values were up to 3%. Attenuation values were between 1 and 2% with the exception of the 30°–50° gantry angles which were up to 3.3%. The ratio values calculated in the ArcCheck for relative dose and absolute dose 10 were both 1·00.ConclusionAttenuation of the treatment beam by the Calypso array is within acceptable limits.
Collapse
|
8
|
Image guidance in radiation therapy: techniques and applications. Radiol Res Pract 2014; 2014:705604. [PMID: 25587445 PMCID: PMC4281403 DOI: 10.1155/2014/705604] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Accepted: 10/28/2014] [Indexed: 12/14/2022] Open
Abstract
In modern day radiotherapy, the emphasis on reduction on volume exposed to high radiotherapy doses, improving treatment precision as well as reducing radiation-related normal tissue toxicity has increased, and thus there is greater importance given to accurate position verification and correction before delivering radiotherapy. At present, several techniques that accomplish these goals impeccably have been developed, though all of them have their limitations. There is no single method available that eliminates treatment-related uncertainties without considerably adding to the cost. However, delivering “high precision radiotherapy” without periodic image guidance would do more harm than treating large volumes to compensate for setup errors. In the present review, we discuss the concept of image guidance in radiotherapy, the current techniques available, and their expected benefits and pitfalls.
Collapse
|
9
|
Abstract
AbstractPurposeCalypso® 4D Localization System is a system based on electromagnetic transponders detection enabling precise 3D localisation and continuous tracking of tumour target. This review intended to provide information in order to (1) show how Calypso® 4D Localization System works, (2) to present advantages and disadvantages of this system, (3) to gather information from several clinical studies and, finally, (4) to refer Calypso® System as a tool in dynamic multileaf collimator studies for target motion compensation.MethodsA structured search was carried out on B-On platform. The key words used in this research were ‘Calypso’, ‘Transponder’, ‘Electromagnetic Localization’, ‘Electromagnetic Tracking’, ‘Target Localization’, ‘Intrafraction Motion’ and ‘DMLC’.ReviewTreatment the implanted transponders are excited by an electromagnetic field and resonate back. These frequencies are detected and Calypso® software calculates the position of the transponders. If the movement detected is larger than the limits previously defined, irradiation can be stopped. The system has been proven to be submillimetre accurate.DiscussionCalypso® System has been presented as an accurate tool in prostate radiotherapy treatments. The application of this system to other clinical sites is being developed.ConclusionThe Calypso® System allows real-time localisation and monitoring of the target, without additional ionising radiation administration. It has been a very useful tool in prostate cancer treatment.
Collapse
|
10
|
De Los Santos J, Popple R, Agazaryan N, Bayouth JE, Bissonnette JP, Bucci MK, Dieterich S, Dong L, Forster KM, Indelicato D, Langen K, Lehmann J, Mayr N, Parsai I, Salter W, Tomblyn M, Yuh WTC, Chetty IJ. Image guided radiation therapy (IGRT) technologies for radiation therapy localization and delivery. Int J Radiat Oncol Biol Phys 2013; 87:33-45. [PMID: 23664076 DOI: 10.1016/j.ijrobp.2013.02.021] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2012] [Revised: 02/14/2013] [Accepted: 02/16/2013] [Indexed: 12/27/2022]
Affiliation(s)
- Jennifer De Los Santos
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Willoughby T, Lehmann J, Bencomo JA, Jani SK, Santanam L, Sethi A, Solberg TD, Tome WA, Waldron TJ. Quality assurance for nonradiographic radiotherapy localization and positioning systems: report of Task Group 147. Med Phys 2012; 39:1728-47. [PMID: 22482598 DOI: 10.1118/1.3681967] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
New technologies continue to be developed to improve the practice of radiation therapy. As several of these technologies have been implemented clinically, the Therapy Committee and the Quality Assurance and Outcomes Improvement Subcommittee of the American Association of Physicists in Medicine commissioned Task Group 147 to review the current nonradiographic technologies used for localization and tracking in radiotherapy. The specific charge of this task group was to make recommendations about the use of nonradiographic methods of localization, specifically; radiofrequency, infrared, laser, and video based patient localization and monitoring systems. The charge of this task group was to review the current use of these technologies and to write quality assurance guidelines for the use of these technologies in the clinical setting. Recommendations include testing of equipment for initial installation as well as ongoing quality assurance. As the equipment included in this task group continues to evolve, both in the type and sophistication of technology and in level of integration with treatment devices, some of the details of how one would conduct such testing will also continue to evolve. This task group, therefore, is focused on providing recommendations on the use of this equipment rather than on the equipment itself, and should be adaptable to each user's situation in helping develop a comprehensive quality assurance program.
Collapse
Affiliation(s)
- Twyla Willoughby
- Task Group 147, Department of Radiation Physics, Orlando, FL, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Foster RD, Pistenmaa DA, Solberg TD. A comparison of radiographic techniques and electromagnetic transponders for localization of the prostate. Radiat Oncol 2012; 7:101. [PMID: 22720845 PMCID: PMC3431985 DOI: 10.1186/1748-717x-7-101] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2012] [Accepted: 06/05/2012] [Indexed: 11/25/2022] Open
Abstract
Background The aim of this study is to compare three methodologies of prostate localization and to determine if there are significant differences in the techniques. Methods Daily prostate localization using cone beam CT or orthogonal kV imaging has been performed at UT Southwestern Medical Center since 2006. Prostate patients are implanted with gold seeds, which are matched with the planning CT or DRR before treatment. More recently, a technology using electromagnetic transponders implanted within the prostate was introduced into our clinic (Calypso®). With each technology, patients are localized initially using skin marks and the room lasers. In this study, patients were localized with Calypso and either CBCT or kV orthogonal images in the same treatment session, allowing a direct comparison of the technologies. Localization difference distributions were determined from the difference in the offsets determined by CBCT/kV imaging and Calypso. CBCT-Calypso and kV imaging-Calypso localization data were summarized from over 900 and 250 fractions each, respectively. The Wilcoxon signed rank test is used to determine if the localization differences are statistically significant. We also calculated Pearson’s product–moment correlation coefficient (R2) to determine if there is a linear relationship between the shifts determined by Calypso and the radiographic techniques. Results The differences between CBCT-Calypso and kV imaging-Calypso localizations are −0.18 ± 2.90 mm, -0.79 ± 2.18 mm, -0.01 ± 1.20 mm and −0.09 ± 1.40 mm, 0.48 ± 1.50 mm, 0.08 ± 1.04 mm, respectively, in the AP, SI, and RL directions. The Pearson product–moment correlation coefficients for the CBCT-Calypso shifts were 0.71, 0.92 and 0.88 and for the OBI-Calypso comparison were 0.95, 0.89 and 0.85. The percentage of localization differences that were less than 3 mm were 86.1%, 84.5% and 96.0% for the CBCT-Calypso comparison and 95.8%, 94.3% and 97% for the kV OBI-Calypso comparison. No trends were observed in the Bland-Altman analysis. Conclusions Localization of the prostate using electromagnetic transponders agrees well with radiographic techniques and each technology is suitable for high precision radiotherapy. This study finds that there is more uncertainty in CBCT localization of the prostate than in 2D orthogonal imaging, but the difference is not clinically significant.
Collapse
Affiliation(s)
- Ryan D Foster
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX 75390-9183, USA.
| | | | | |
Collapse
|
13
|
The dosimetric impact of prostate rotations during electromagnetically guided external-beam radiation therapy. Int J Radiat Oncol Biol Phys 2012; 85:230-6. [PMID: 22554583 DOI: 10.1016/j.ijrobp.2012.03.020] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2011] [Revised: 08/20/2011] [Accepted: 03/14/2012] [Indexed: 11/23/2022]
Abstract
PURPOSE To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). METHODS AND MATERIALS Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation therapy plans meeting RTOG 0126 dosimetric criteria were created with 0-, 2-, 3-, and 5-mm planning target volume (PTV) margins. Daily translations and rotations were used to reconstruct prostate delivered dose from the planned dose. D95 and V79 were computed from the delivered dose to evaluate target coverage and the adequacy of PTV margins. Prostate equivalent rotation is a new metric introduced in this study to quantify prostate rotations by accounting for prostate shape and length of rotational lever arm. RESULTS Large variations in prostate delivered dose were seen among patients. Adequate target coverage was met in 39%, 65%, and 84% of the patients for plans with 2-, 3-, and 5-mm PTV margins, respectively. Although no correlations between prostate delivered dose and daily rotations were seen, the data showed a clear correlation with prostate equivalent rotation. CONCLUSIONS Prostate rotations during RT could cause significant underdosing even if daily translations were managed. These rotations should be managed with rotational tolerances based on prostate equivalent rotations.
Collapse
|
14
|
D'Ambrosio DJ, Bayouth J, Chetty IJ, Buyyounouski MK, Price RA, Correa CR, Dilling TJ, Franklin GE, Xia P, Harris EER, Konski A. Continuous localization technologies for radiotherapy delivery: Report of the American Society for Radiation Oncology Emerging Technology Committee. Pract Radiat Oncol 2011; 2:145-50. [PMID: 24175000 PMCID: PMC3808750 DOI: 10.1016/j.prro.2011.10.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2011] [Revised: 10/20/2011] [Accepted: 10/24/2011] [Indexed: 10/28/2022]
Affiliation(s)
- David J D'Ambrosio
- Department of Radiation Oncology, Community Medical Center, Toms River, New Jersey.
| | - John Bayouth
- Department of Radiation Oncology, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - Indrin J Chetty
- Department of Radiation Oncology, Henry Ford Hospital and Health Centers, Detroit, Michigan
| | - Mark K Buyyounouski
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania
| | - Robert A Price
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania
| | - Candace R Correa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Thomas J Dilling
- Division of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida
| | - Gregg E Franklin
- Department of Radiation Oncology, New Mexico Cancer Center, Albuquerque, New Mexico
| | - Ping Xia
- Department of Radiation Oncology, Cleveland Clinic, Cleveland, Ohio
| | - Eleanor E R Harris
- Department of Radiation Oncology, H. Lee Moffit Cancer Center, Tampa, Florida
| | - Andre Konski
- Department of Radiation Oncology, Wayne State University School of Medicine, Detroit, Michigan
| |
Collapse
|
15
|
Shah AP, Kupelian PA, Willoughby TR, Meeks SL. Expanding the use of real-time electromagnetic tracking in radiation oncology. J Appl Clin Med Phys 2011; 12:3590. [PMID: 22089017 PMCID: PMC5718735 DOI: 10.1120/jacmp.v12i4.3590] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2011] [Revised: 06/15/2011] [Accepted: 06/14/2011] [Indexed: 12/02/2022] Open
Abstract
In the past 10 years, techniques to improve radiotherapy delivery, such as intensity‐modulated radiation therapy (IMRT), image‐guided radiation therapy (IGRT) for both inter‐ and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery. PACS number: 87.63.‐d
Collapse
Affiliation(s)
- Amish P Shah
- Department of Radiation Oncology, MD Anderson Cancer Center Orlando, Orlando, Florida 32806, USA.
| | | | | | | |
Collapse
|
16
|
Prostate intrafraction translation margins for real-time monitoring and correction strategies. Prostate Cancer 2011; 2012:130579. [PMID: 22111005 PMCID: PMC3195290 DOI: 10.1155/2012/130579] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2011] [Accepted: 05/12/2011] [Indexed: 12/25/2022] Open
Abstract
The purpose of this work is to determine appropriate radiation therapy beam margins to account for intrafraction prostate translations for use with real-time electromagnetic position monitoring and correction strategies. Motion was measured continuously in 35 patients over 1157 fractions at 5 institutions. This data was studied using van Herk's formula of (αΣ + γσ') for situations ranging from no electromagnetic guidance to automated real-time corrections. Without electromagnetic guidance, margins of over 10 mm are necessary to ensure 95% dosimetric coverage while automated electromagnetic guidance allows the margins necessary for intrafraction translations to be reduced to submillimeter levels. Factors such as prostate deformation and rotation, which are not included in this analysis, will become the dominant concerns as margins are reduced. Continuous electromagnetic monitoring and automated correction have the potential to reduce prostate margins to 2-3 mm, while ensuring that a higher percentage of patients (99% versus 90%) receive a greater percentage (99% versus 95%) of the prescription dose.
Collapse
|
17
|
Block AM, Lin J, Hoggarth MA, Quinn M, Garza R, Mantz CA, Roeske JC. Dose-volume factors to select patient-specific image-guidance action thresholds in prostate cancer. Technol Cancer Res Treat 2011; 10:211-7. [PMID: 21517127 DOI: 10.7785/tcrt.2012.500196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
For radiation delivery tracking systems that monitor intrafraction prostate motion, generalized departmental threshold protocols may be used. The purpose of this study is to determine whether predefined action thresholds can be generally applied or if patient-specific action thresholds may be required. Software algorithms were developed in the MatLab (The Mathworks Inc., Natick, MA) software environment to simulate shifts of the patient structure set consisting of prostate, bladder, and rectum. These structures were shifted by 1/2 10 mm in each direction in 1 mm increments to simulate displacements during treatment, without taking into consideration organ deformity. Dose-volume data at each shift were plotted and analyzed. A linear relationship was observed between planning dose-volume parameters and shifted dose-volume parameters. For a 5 mm anterior shift, it was observed that individual rectal V70 values increased by absolute magnitudes of 6-15%, dependent on the planning rectal V70 of each patient. Likewise, for a 5 mm inferior shift, individual bladder V70 values increased by 1-14%, dependent on planning bladder V70. This linear relationship was observed for all levels of shifts up to 10 mm. Since rectum and bladder dose-volume changes due to patient shifts are dependent on dose-volume parameters, this study suggests that patient-specific action thresholds may be necessary.
Collapse
Affiliation(s)
- A M Block
- Stritch School of Medicine and Department of Radiation Oncology, Loyola University Medical Center, 2160 S. First Ave. Maguire Center - Rm. 2946, Maywood, IL 60153, USA
| | | | | | | | | | | | | |
Collapse
|
18
|
Nath SK, Sandhu AP, Sethi RA, Jensen LG, Rosario MD, Kane CJ, Parsons JK, Millard FE, Jiang SB, Rice RK, Pawlicki T, Mundt AJ. Target Localization and Toxicity in Dose-Escalated Prostate Radiotherapy with Image-Guided Approach using Daily Planar Kilovoltage Imaging. Technol Cancer Res Treat 2011; 10:31-7. [DOI: 10.7785/tcrt.2012.500177] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Dose escalation with intensity-modulated radiation therapy (IMRT) for carcinoma of the prostate has augmented the need for accurate prostate localization prior to dose delivery. Daily planar kilovoltage (kV) imaging is a low-dose image-guidance technique that is prevalent among radiation oncologists. However, clinical outcomes evaluating the benefit of daily kV imaging are lacking. The purpose of this study was to report our clinical experience, including prostate motion and gastrointestinal (GI) and genitourinary (GU) toxicities, using this modality. A retrospective analysis of 100 patients treated consecutively between December 2005 and March 2008 with definitive external beam IMRT for T1c-T4 disease were included in this analysis. Prescription doses ranged from 74–78 Gy (median, 76) in 2 Gy fractions and were delivered following daily prostate localization using on-board kV imaging (OBI) to localize gold seed fiducial markers within the prostate. Acute and late toxicities were graded as per the NCI CTCAEv3.0. The median follow-up was 22 months. The magnitude and direction of prostate displacement and daily shifts in three axes are reported. Of note, 9.1% and 12.9% of prostate displacements were ≥ 5 mm in the anterior-posterior and superior-inferior directions, respectively. Acute grade 2 GI and GU events occurred in 11% and 39% of patients, respectively, however no grade 3 or higher acute GI or GU events were observed. Regarding late toxicity, 2% and 17% of patients developed grade 2 toxicities, and similarly no grade 3 or higher events had occurred by last follow-up. Thus, kV imaging detected a substantial amount of inter-fractional displacement and may help reduce toxicity profiles, especially high grade events, by improving the accuracy of dose delivery.
Collapse
Affiliation(s)
- S. K. Nath
- Department of Radiation Oncology
- Center for Advanced Radiotherapy Technologies University of California San Diego 3855 Health Sciences Drive, #0843 La Jolla, CA 92093-0843, USA
| | | | | | - L. G. Jensen
- Department of Radiation Oncology
- Center for Advanced Radiotherapy Technologies University of California San Diego 3855 Health Sciences Drive, #0843 La Jolla, CA 92093-0843, USA
| | | | - C. J. Kane
- Department of Surgery, Division of Urologic Oncology
| | - J. K. Parsons
- Department of Surgery, Division of Urologic Oncology
| | - F. E. Millard
- Department of Medicine, Division of Hematology and Oncology Moores Comprehensive Cancer Center
| | - S. B. Jiang
- Department of Radiation Oncology
- Center for Advanced Radiotherapy Technologies University of California San Diego 3855 Health Sciences Drive, #0843 La Jolla, CA 92093-0843, USA
| | | | | | - A. J. Mundt
- Department of Radiation Oncology
- Center for Advanced Radiotherapy Technologies University of California San Diego 3855 Health Sciences Drive, #0843 La Jolla, CA 92093-0843, USA
| |
Collapse
|
19
|
King BL, Butler WM, Merrick GS, Kurko BS, Reed JL, Murray BC, Wallner KE. Electromagnetic transponders indicate prostate size increase followed by decrease during the course of external beam radiation therapy. Int J Radiat Oncol Biol Phys 2010; 79:1350-7. [PMID: 20605348 DOI: 10.1016/j.ijrobp.2009.12.053] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2009] [Revised: 12/07/2009] [Accepted: 12/20/2009] [Indexed: 01/10/2023]
Abstract
PURPOSE Real-time image guidance enables more accurate radiation therapy by tracking target movement. This study used transponder positions to monitor changes in prostate volume that may be a source of dosimetric and target inaccuracy. METHODS AND MATERIALS Twenty-four men with biopsy-proven T1c-T3a prostate cancer each had three electromagnetic transponders implanted transperineally. Their coordinates were recorded by the Calypso system, and the perimeter of the triangle formed by the transponders was used to calculate prostate volumes at sequential time points throughout the course of radiation therapy to a dose of 81 Gy in 1.8-Gy fractions. RESULTS There was a significant decrease in mean prostate volume of 10.9% from the first to the final day of radiation therapy. The volume loss did not occur monotonically but increased in most patients (75%) during the first several weeks to a median maximum on Day 7. The volume increased by a mean of 6.1% before decreasing by a mean maximum difference of 18.4% to nadir (p < 0.001 for both increase and decrease). Glandular shrinkage was asymmetric, with the apex to right base dimension varying more than twice that of the lateral dimension. For all dimensions, the mean change was <0.5 cm. CONCLUSION Real-time transponder positions indicated a volume increase during the initial days of radiation therapy and then significant and asymmetric shrinkage by the final day. Understanding and tracking volume fluctuations of the prostate during radiation therapy can help real-time imaging technology perform to its fullest potential.
Collapse
Affiliation(s)
- Benjamin L King
- Radiation Oncology Department, University of Washington, Seattle, WA, USA
| | | | | | | | | | | | | |
Collapse
|
20
|
Noel CE, Santanam L, Olsen JR, Baker KW, Parikh PJ. An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking. Phys Med Biol 2010; 55:65-82. [PMID: 19949260 DOI: 10.1088/0031-9155/55/1/005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects of intra- and inter-fraction target motion for prostate cancer patients using fiducial-based electromagnetic tracking. A computer program utilizing real-time tracking data was written to (1) prospectively determine appropriate rotational/translational motion limits for patients treated with continuous isocenter localization; (2) retrospectively analyze dosimetric target coverage after daily treatment, and (3) visualize three-dimensional rotations and translations of the prostate with respect to the planned target volume and dose matrix. We present phantom testing and a patient case to validate and demonstrate the utility of this application. Gamma analysis of planar dose computed by our application demonstrated accuracy within 1%/1 mm. Dose computation of a patient treatment revealed high variation in minimum dose to the prostate (D(min)) over 40 fractions and a drop in the D(min) of approximately 8% between a 5 mm and a 3 mm PTV margin plan. The infrastructure has been created for patient-specific treatment evaluation using continuous tracking data. This application can be used to increase confidence in treatment delivery to targets influenced by motion.
Collapse
Affiliation(s)
- C E Noel
- Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, St Louis, MO 63110, USA
| | | | | | | | | |
Collapse
|
21
|
Foster RD, Solberg TD, Li HS, Kerkhoff A, Enke CA, Willoughby TR, Kupelian PA. Comparison of transabdominal ultrasound and electromagnetic transponders for prostate localization. J Appl Clin Med Phys 2010; 11:2924. [PMID: 20160686 PMCID: PMC5719783 DOI: 10.1120/jacmp.v11i1.2924] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2008] [Revised: 10/15/2009] [Accepted: 10/14/2009] [Indexed: 12/25/2022] Open
Abstract
The aim of this study is to compare two methodologies of prostate localization in a large cohort of patients. Daily prostate localization using B‐mode ultrasound has been performed at the Nebraska Medical Center since 2000. More recently, a technology using electromagnetic transponders implanted within the prostate was introduced into our clinic (Calypso). With each technology, patients were localized initially using skin marks. Localization error distributions were determined from offsets between the initial setup positions and those determined by ultrasound or Calypso. Ultrasound localization data was summarized from 16,619 imaging sessions spanning seven years. Calypso localization data consists of 1524 fractions in 41 prostate patients treated in the course of a clinical trial at five institutions and 640 localizations from the first 16 patients treated with our clinical system. Ultrasound and Calypso patients treated between March and September 2007 at the Nebraska Medical Center were analyzed and compared, allowing a single institutional comparison of the two technologies. In this group of patients, the isocenter determined by ultrasound‐based localization is on average 5.3 mm posterior to that determined by Calypso, while the systematic and random errors and PTV margins calculated from the ultrasound localizations were 3–4 times smaller than those calculated from the Calypso localizations. Our study finds that there are systematic differences between Calypso and ultrasound for prostate localization. PACS number: 87.63.dh
Collapse
Affiliation(s)
- Ryan D Foster
- Department of Radiation Oncology, UT Southwestern Medical Center at Dallas, Dallas, TX 75390-9183, USA.
| | | | | | | | | | | | | |
Collapse
|
22
|
Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking. Int J Radiat Oncol Biol Phys 2009; 74:575-82. [DOI: 10.1016/j.ijrobp.2008.12.057] [Citation(s) in RCA: 95] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2008] [Revised: 12/18/2008] [Accepted: 12/19/2008] [Indexed: 12/25/2022]
|
23
|
Noel C, Parikh PJ, Roy M, Kupelian P, Mahadevan A, Weinstein G, Enke C, Flores N, Beyer D, Levine L. Prediction of Intrafraction Prostate Motion: Accuracy of Pre- and Post-Treatment Imaging and Intermittent Imaging. Int J Radiat Oncol Biol Phys 2009; 73:692-8. [DOI: 10.1016/j.ijrobp.2008.04.076] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2007] [Revised: 04/22/2008] [Accepted: 04/25/2008] [Indexed: 11/16/2022]
|
24
|
Chen GTY, Sharp GC, Mori S. A review of image-guided radiotherapy. Radiol Phys Technol 2009; 2:1-12. [DOI: 10.1007/s12194-008-0045-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2008] [Revised: 10/27/2008] [Accepted: 10/27/2008] [Indexed: 11/25/2022]
|
25
|
Murphy MJ, Eidens R, Vertatschitsch E, Wright JN. The Effect of Transponder Motion on the Accuracy of the Calypso Electromagnetic Localization System. Int J Radiat Oncol Biol Phys 2008; 72:295-9. [PMID: 18722280 DOI: 10.1016/j.ijrobp.2008.05.036] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2008] [Revised: 05/12/2008] [Accepted: 05/14/2008] [Indexed: 11/17/2022]
Affiliation(s)
- Martin J Murphy
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298-0058, USA.
| | | | | | | |
Collapse
|
26
|
Rau AW, Nill S, Eidens RS, Oelfke U. Synchronized tumour tracking with electromagnetic transponders and kV x-ray imaging: evaluation based on a thorax phantom. Phys Med Biol 2008; 53:3789-805. [PMID: 18574313 DOI: 10.1088/0031-9155/53/14/006] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Intrafractional organ motion remains a source of error in conformal radiotherapy of dynamic targets such as tumours of the lung or of the prostate. The purpose of this work was to devise a method for the continuous and routine measurement of intrafractional organ motion. The method consists of a combination of an electromagnetic (EM), internal marker-based tracking system with the on-board kilovoltage x-ray imaging system of a modern treatment machine. The EM system continuously tracks the target, while x-ray images can be acquired simultaneously if demand arises. An image processing algorithm has been developed to automatically localize and track the EM markers in the x-ray images. We have demonstrated simultaneous target tracking using the EM system and x-ray imaging of a mobile target inside a programmable thorax phantom. The target motion was very well reproduced by both systems. The comparability of the target locations reported by both systems was established (better than 0.25 mm up to target velocities of 3 cm s(-1)). One immediate use of the synchronized system was shown: the generation of a 4D cone beam computed tomography data set using the EM system for the measurement of motion. In conclusion, we have developed a system for the routine measurement of intrafractional motion that continuously provides the 3D position of the target with the ability to acquire images of the treatment field only when needed, thereby eliminating avoidable imaging dose to the patient.
Collapse
Affiliation(s)
- A W Rau
- German Cancer Research Center, Div. Medical Physics in Radiation Oncology, INF 280, 69120 Heidelberg, Germany.
| | | | | | | |
Collapse
|
27
|
Abstract
The goal of radiation therapy is to achieve maximal therapeutic benefit expressed in terms of a high probability of local control of disease with minimal side effects. Physically this often equates to the delivery of a high dose of radiation to the tumour or target region whilst maintaining an acceptably low dose to other tissues, particularly those adjacent to the target. Techniques such as intensity modulated radiotherapy (IMRT), stereotactic radiosurgery and computer planned brachytherapy provide the means to calculate the radiation dose delivery to achieve the desired dose distribution. Imaging is an essential tool in all state of the art planning and delivery techniques: (i) to enable planning of the desired treatment, (ii) to verify the treatment is delivered as planned and (iii) to follow-up treatment outcome to monitor that the treatment has had the desired effect. Clinical imaging techniques can be loosely classified into anatomic methods which measure the basic physical characteristics of tissue such as their density and biological imaging techniques which measure functional characteristics such as metabolism. In this review we consider anatomical imaging techniques. Biological imaging is considered in another article. Anatomical imaging is generally used for goals (i) and (ii) above. Computed tomography (CT) has been the mainstay of anatomical treatment planning for many years, enabling some delineation of soft tissue as well as radiation attenuation estimation for dose prediction. Magnetic resonance imaging is fast becoming widespread alongside CT, enabling superior soft-tissue visualization. Traditionally scanning for treatment planning has relied on the use of a single snapshot scan. Recent years have seen the development of techniques such as 4D CT and adaptive radiotherapy (ART). In 4D CT raw data are encoded with phase information and reconstructed to yield a set of scans detailing motion through the breathing, or cardiac, cycle. In ART a set of scans is taken on different days. Both allow planning to account for variability intrinsic to the patient. Treatment verification has been carried out using a variety of technologies including: MV portal imaging, kV portal/fluoroscopy, MVCT, conebeam kVCT, ultrasound and optical surface imaging. The various methods have their pros and cons. The four x-ray methods involve an extra radiation dose to normal tissue. The portal methods may not generally be used to visualize soft tissue, consequently they are often used in conjunction with implanted fiducial markers. The two CT-based methods allow measurement of inter-fraction variation only. Ultrasound allows soft-tissue measurement with zero dose but requires skilled interpretation, and there is evidence of systematic differences between ultrasound and other data sources, perhaps due to the effects of the probe pressure. Optical imaging also involves zero dose but requires good correlation between the target and the external measurement and thus is often used in conjunction with an x-ray method. The use of anatomical imaging in radiotherapy allows treatment uncertainties to be determined. These include errors between the mean position at treatment and that at planning (the systematic error) and the day-to-day variation in treatment set-up (the random error). Positional variations may also be categorized in terms of inter- and intra-fraction errors. Various empirical treatment margin formulae and intervention approaches exist to determine the optimum strategies for treatment in the presence of these known errors. Other methods exist to try to minimize error margins drastically including the currently available breath-hold techniques and the tracking methods which are largely in development. This paper will review anatomical imaging techniques in radiotherapy and how they are used to boost the therapeutic benefit of the treatment.
Collapse
Affiliation(s)
- Philip M Evans
- Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT, UK.
| |
Collapse
|
28
|
Lee WR. Reducing biochemical recurrence rates in EBRT-treated prostate cancer patients: the influence of dose and dose per fraction. Future Oncol 2008; 3:649-54. [PMID: 18041917 DOI: 10.2217/14796694.3.6.649] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
In the last 15-20 years, technological improvements in radiation treatment planning and delivery have allowed radiation oncologists to increase the total dose to the prostate gland. The results of four randomized trials using conventional daily doses (1.8-2 Gy) demonstrate that higher total doses lead to lower rates of biochemical recurrence, but with a modest increase in late toxicity. Preclinical data suggest that treatment schedules relying on fewer, larger daily fractions of radiotherapy (hypofractionation) may increase the therapeutic ratio. Early results from several uncontrolled trials indicate that schedules that rely on larger daily doses are associated with low toxicity, provided some form of daily target localization and sophisticated treatment delivery are used. The results of several randomized trials that compare hypofractionated regimens to conventionally fractionated regimens will be available in the next 5-10 years.
Collapse
Affiliation(s)
- W Robert Lee
- Duke University School of MedicineDurham, NC 27710, USA.
| |
Collapse
|
29
|
Verellen D, Ridder MD, Storme G. A (short) history of image-guided radiotherapy. Radiother Oncol 2008; 86:4-13. [DOI: 10.1016/j.radonc.2007.11.023] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2007] [Revised: 11/18/2007] [Accepted: 11/20/2007] [Indexed: 12/25/2022]
|
30
|
Verellen D, De Ridder M, Linthout N, Tournel K, Soete G, Storme G. Innovations in image-guided radiotherapy. Nat Rev Cancer 2007; 7:949-60. [PMID: 18034185 DOI: 10.1038/nrc2288] [Citation(s) in RCA: 269] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The limited ability to control for the location of a tumour compromises the accuracy with which radiation can be delivered to tumour-bearing tissue. The resultant requirement for larger treatment volumes to accommodate target uncertainty restricts the radiation dose because more surrounding normal tissue is exposed. With image-guided radiotherapy (IGRT) these volumes can be optimized and tumoricidal doses can be delivered, achieving maximal tumour control with minimal complications. Moreover, with the ability of high-precision dose delivery and real-time knowledge of the target volume location, IGRT has initiated the exploration of new indications for radiotherapy, some of which were previously considered infeasible.
Collapse
Affiliation(s)
- Dirk Verellen
- UZ Brussel, Oncologisch Centrum, Radiotherapie, Laarbeeklaan 101, B-1090 Brussels, Belgium.
| | | | | | | | | | | |
Collapse
|