1
|
Hu Y, Seum WCTH, Hunzeker A, Muller O, Foote RL, Mundy DW. The effect of common dental fixtures on treatment planning and delivery for head and neck intensity modulated proton therapy. J Appl Clin Med Phys 2023; 24:e13973. [PMID: 36972299 PMCID: PMC10338740 DOI: 10.1002/acm2.13973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 03/06/2023] [Accepted: 03/09/2023] [Indexed: 07/20/2023] Open
Abstract
PURPOSE Proton treatment plan perturbation by common dental fixtures such as amalgams (Am) and porcelain-fused-to-metal (PFM) crowns has, to date, been uncharacterized. Previous studies have been conducted to determine the physical effect of these materials within the beam path for single spots, but their effects on complex treatment plans and clinical anatomy have not yet been quantified. The present manuscript aims to study the effect of Am and PFM fixtures on proton treatment planning in a clinical setting. METHODS An anthropomorphic phantom with removable tongue, maxilla, and mandible modules was simulated on a clinical computed tomography (CT) scanner. Spare maxilla modules were modified to include either a 1.5 mm depth central groove occlusal amalgam (Am) or a porcelain-fused-to-metal (PFM) crown, implanted on the first right molar. Modified tongue modules were 3D printed to accommodate several axial or sagittal oriented pieces of EBT-3 film. Clinically representative spot-scanning proton plans were generated in Eclipse v.15.6 using the proton convolution superposition (PCS) algorithm v.15.6.06 using a multi-field optimization (MFO) technique with the goal of delivering a uniform 54 Gy dose to a clinical target volume (CTV) typical of a base-of-tongue (BoT) treatment. A typical geometric beam arrangement of two anterior oblique (AO) beams and a posterior beam was employed. Plans optimized without any material overrides were delivered to the phantom A) without implants; B) with Am fixture; or C) with PFM crown. Plans were also reoptimized and delivered with inclusion of material overrides to equate relative stopping power of the fixture with that of a previously measured result. RESULTS Plans exhibit slightly greater dose weight towards AO beams. The optimizer accounted for inclusion of fixture overrides by increasing beam weights to the beam closest to the implant. Film measurements exhibited cold spots directly within the beam path through the fixture in plans with and without overridden materials. Cold spots were somewhat mitigated in plans including overridden materials in the structure set but were not entirely eliminated. Cold spots associated with Am and PFM fixtures were quantified at 17% and 14% for plans without overrides, respectively, and 11% and 9% with using Monte Carlo simulation. Compared with film measurements and Monte Carlo simulation, the treatment planning system underestimates the dose shadowing effect in plans including material overrides. CONCLUSIONS Dental fixtures create a dose shadowing effect directly in line with the beam path through the material. This cold spot is partially mitigated by overriding the material to measured relative stopping powers. Due to uncertainties in modeling perturbation through the fixture, the magnitude of the cold spot is underestimated using the institutional TPS when compared to measurement and MC simulation.
Collapse
Affiliation(s)
- Yue‐Houng Hu
- Department of Radiation OncologyDivision of Medical Physics and BiophysicsBrigham and Women's HospitalDana‐Farber Cancer Institute, and Harvard Medical SchoolBostonMassachusettsUSA
| | | | - Ashley Hunzeker
- Department of Radiation OncologyDivision of Medical PhysicsMayo ClinicRochesterMinnesotaUSA
| | - Olivia Muller
- Department of Advanced ProsthodonticsMayo ClinicRochesterMinnesotaUSA
| | - Robert L. Foote
- Department of Radiation OncologyDivision of Medical PhysicsMayo ClinicRochesterMinnesotaUSA
| | - Daniel W. Mundy
- Department of Radiation OncologyDivision of Medical PhysicsMayo ClinicRochesterMinnesotaUSA
| |
Collapse
|
2
|
Longarino FK, Herpel C, Tessonnier T, Mein S, Ackermann B, Debus J, Schwindling FS, Stiller W, Mairani A. Dual-energy CT-based stopping power prediction for dental materials in particle therapy. J Appl Clin Med Phys 2023:e13977. [PMID: 37032540 PMCID: PMC10402687 DOI: 10.1002/acm2.13977] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/23/2023] [Accepted: 03/17/2023] [Indexed: 04/11/2023] Open
Abstract
Radiotherapy with protons or light ions can offer accurate and precise treatment delivery. Accurate knowledge of the stopping power ratio (SPR) distribution of the tissues in the patient is crucial for improving dose prediction in patients during planning. However, materials of uncertain stoichiometric composition such as dental implant and restoration materials can substantially impair particle therapy treatment planning due to related SPR prediction uncertainties. This study investigated the impact of using dual-energy computed tomography (DECT) imaging for characterizing and compensating for commonly used dental implant and restoration materials during particle therapy treatment planning. Radiological material parameters of ten common dental materials were determined using two different DECT techniques: sequential acquisition CT (SACT) and dual-layer spectral CT (DLCT). DECT-based direct SPR predictions of dental materials via spectral image data were compared to conventional single-energy CT (SECT)-based SPR predictions obtained via indirect CT-number-to-SPR conversion. DECT techniques were found overall to reduce uncertainty in SPR predictions in dental implant and restoration materials compared to SECT, although DECT methods showed limitations for materials containing elements of a high atomic number. To assess the influence on treatment planning, an anthropomorphic head phantom with a removable tooth containing lithium disilicate as a dental material was used. The results indicated that both DECT techniques predicted similar ranges for beams unobstructed by dental material in the head phantom. When ion beams passed through the lithium disilicate restoration, DLCT-based SPR predictions using a projection-based method showed better agreement with measured reference SPR values (range deviation: 0.2 mm) compared to SECT-based predictions. DECT-based SPR prediction may improve the management of certain non-tissue dental implant and restoration materials and subsequently increase dose prediction accuracy.
Collapse
Affiliation(s)
- Friderike K Longarino
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Department of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Christopher Herpel
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Thomas Tessonnier
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany
- Translational Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | - Stewart Mein
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany
- Translational Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
| | | | - Jürgen Debus
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- German Cancer Consortium (DKTK), Core Center Heidelberg, Heidelberg, Germany
| | | | - Wolfram Stiller
- Diagnostic & Interventional Radiology (DIR), Heidelberg University Hospital, Heidelberg, Germany
| | - Andrea Mairani
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany
- National Center for Tumor Diseases (NCT), Heidelberg, Germany
- Medical Physics, National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| |
Collapse
|
3
|
Hu YH, Wan CTHS, Mundy DW. Physical characterization of therapeutic proton delivery through common dental materials. Med Phys 2022; 49:2904-2913. [PMID: 35276753 DOI: 10.1002/mp.15602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 11/05/2021] [Accepted: 03/07/2022] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Dental fixtures are commonplace in an aging, radiation treatment population. The current, local standard of practice in particle therapy is to employ treatment geometries to avoid delivery through implanted dental fixtures. The present study aims to observe the physical effect of delivering therapeutic proton beams through common dental fixture materials as prelude to an eventual goal of assessing the feasibility of using treatment geometries not specified for avoidance of oral implants. A sampling of common dental materials was selected based on prosthodontic consult and was evaluated in terms of relative stopping power and three-dimensional (3D) dose perturbation. METHODS Amalgams, porcelain-fused-to-metal (PFM) crowns consisting of zirconia and non-noble base metals, and lithium disilicate implants were chosen for analysis. Theoretical stopping power (S) and mass stopping power (S/ρ) were calculated using the Stopping and Range of Ions in Matter (SRIM) application, basing stoichiometric compositions of each fixture on published materials data. S and S/ρ were calculated for a range of historically available compositions of amalgams from 1900 until the current era. The perturbance of S and S/ρ as a function of clinically relevant ranges of amalgam compositions for the modern era was analyzed. Water equivalent thickness (WET) and relative stopping power (Srel ) of each material was measured for a clinical spot-scanning proton beam with monoenergies of 159.9 and 228.8 MeV with a multi-layer ionization chamber (MLIC). Subsequently, 3D dose perturbation was assessed by delivering proton beams through a custom phantom designed to simulate both en-face and on-edge treatment geometries through the selected materials. A treatment plan mimicking the experimental delivery was constructed in the institutional treatment planning system and calculated using TOPAS based Monte Carlo Simulation (MCS). Experimental results were used to validate the MCS. Finally, TPS outputs were compared to MCS to determine the accuracy of the dose calculation model. RESULTS Historical compositions of amalgams ranged in S from 44.8 to 42.9 MeV/cm, with the greatest deviation being observed for the 1900-1959 era. Deviation as a function of amalgam composition from the modern era was most sensitive to proportion of Hg, accounting for deviations up to -4.2% at the greatest clinically relevant concentration. S/ρ was not found to vary greatly between each porcelain and metal alloy material for porcelain-fused-to-metal (PFM) type crowns. Relative stopping powers ranged between 1.3 and 5.4 for all studied materials, suggesting substantial changes in proton range with respect to water. Film measurements of pristine spots confirm dose perturbance and shortening of proton range, with an upstream shift of each Bragg peak being observed directly behind the installed fixture. At high energies, cold spots were found in all cases directly behind each material feature with a medial fill-in of dose occurring distally. Qualitative agreement of spot perturbance was confirmed between film measurements and MCS. Finally, when comparing integrated depth doses (IDD) by summing over all axial directions, good agreement is observed between TPS and MCS. CONCLUSIONS All dental materials studied substantially perturbed the dosimetry of pristine proton spots both in terms of WET/Srel as well as the spatial distribution of dose. Proton range was quantifiably shortened, and each dental material affected a cold spot directly behind the object with medial dose back-filling was observed distally. Monte Carlo simulations and Eclipse dose calculations exhibited good agreement with measurements, suggesting that treatment planning without employing avoidance strategies may be possible with further investigation. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Yue-Houng Hu
- Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Rochester, MN, 55902, USA.,Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women's Hospital, Dana-Farber Cancer Institute, and Harvard Medical School, Boston, MA, 02115, USA
| | - Chan Tseung Hok Seum Wan
- Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Rochester, MN, 55902, USA
| | - Daniel W Mundy
- Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Rochester, MN, 55902, USA
| |
Collapse
|