1
|
Chen Z, Li Z, Huang YH, Teng X, Zhang J, Xiong T, Dong Y, Song L, Ren G, Cai J. Anatomy-wise lung ventilation imaging for precise functional lung avoidance radiation therapy. Phys Med Biol 2025; 70:045019. [PMID: 39889343 DOI: 10.1088/1361-6560/adb123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Accepted: 01/31/2025] [Indexed: 02/03/2025]
Abstract
Objective.This study aimed to propose a method for obtaining anatomy-wise lung ventilation image (VIaw) that enables functional assessment of lung parenchyma and tumor-blocked pulmonary segments. The VIawwas used to define multiple functional volumes of the lung and thereby support radiation treatment planning.Approach.A super-voxel-based method was employed for functional assessment of lung parenchyma to generate VIsvd. In the VIsvdof the 11 patients with tumor blockage of the airway, the functional value in tumor-blocked segments was set to 0 to generate the VIaw. The lung was divided into regions of high functional volume (HFV), unrecoverable low functional volume (LFV), and recoverable LFV (rLFV, the region in the tumor-blocked segment with a high function value based on the VIsvd) to design three intensity-modulated photon plans for five patients. These plans were an anatomical-lung-guided plan (aPlan), a functional-lung-guided plan (fPlan), and a recoverable functional-lung-guided plan (rfPlan) where the latter protected both HFV and rLFV.Main results.The LFV in the reference ventilation images and the tumor-blocked segments had a high overlap similarity coefficient value of 0.90 ± 0.07. The mean Spearman correlation between the VIawand reference ventilation images was 0.72 ± 0.05 for the patient with tumor blockage of the airway. TheV20 and mean dose of rLFV in rfPlan were lower than those in aPlan by 12.1 ± 8.4% and 13.0 ± 6.4%, respectively, and lower than those in fPlan by 14.9 ± 9.8% and 15.9 ± 6.5%, respectively.Significance.The VIawcan reach a moderate-strong correlation with reference ventilation images and thus can identify rLFV to support treatment planning to preserve lung function.
Collapse
Affiliation(s)
- Zhi Chen
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Zihan Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Yu-Hua Huang
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Xinzhi Teng
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Jiang Zhang
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Tianyu Xiong
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Yanjing Dong
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Liming Song
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Ge Ren
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region of China, People's Republic of China
| |
Collapse
|
2
|
Yu J, Tang X, Lei Y, Zhang Z, Li B, Bai H, Li L. A review on functional lung avoidance radiotherapy plan for lung cancer. Front Oncol 2024; 14:1429837. [PMID: 39703855 PMCID: PMC11656049 DOI: 10.3389/fonc.2024.1429837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Accepted: 11/11/2024] [Indexed: 12/21/2024] Open
Abstract
Lung cancer is the most common malignant tumor in China. Its incidence and mortality rate increase year by year. In the synthesis treatment of lung cancer, radiotherapy (RT) plays a vital role, and radiation-induced lung injury(RILI) has become the major limiting factor in prescription dose escalation. Conventional RT is designed to minimize radiation exposure to healthy lungs without considering the inhomogeneity of lung function, which is significantly non-uniform in most patients. In accordance with the functional and structural heterogeneity of lung tissue, functional lung avoidance RT (FLART) can reduce radiation exposure to functional lung (FL), thus reducing RILI. Meanwhile, a dose-function histogram (DFH) was proposed to describe the dose parameters of the optimized image-guided RT plan. This paper reviews lung function imaging for lung cancer RT plans. It also reviews the clinical applications of function-guided RT plans and their current problems and research directions to provide better guidance for clinical selection.
Collapse
Affiliation(s)
- Jinhui Yu
- The Third Affiliated Hospital of Kunming Medical University, Kunming Medical University, Kunming, Yunnan, China
| | - Xiaofeng Tang
- Department of Radiation Oncology, The Third Affiliated Hospital of Kunming Medical University, Yunnan Tumor Hospital, Kunming, Yunnan, China
| | - Yifan Lei
- The Third Affiliated Hospital of Kunming Medical University, Kunming Medical University, Kunming, Yunnan, China
| | - Zhe Zhang
- The Third Affiliated Hospital of Kunming Medical University, Kunming Medical University, Kunming, Yunnan, China
| | - Bo Li
- The Third Affiliated Hospital of Kunming Medical University, Kunming Medical University, Kunming, Yunnan, China
| | - Han Bai
- Department of Radiation Oncology, The Third Affiliated Hospital of Kunming Medical University, Yunnan Tumor Hospital, Kunming, Yunnan, China
- Department of Physics and Astronomy, Yunnan University, Kunming, Yunnan, China
| | - Lan Li
- Department of Radiation Oncology, The Third Affiliated Hospital of Kunming Medical University, Yunnan Tumor Hospital, Kunming, Yunnan, China
| |
Collapse
|
3
|
Klaar R, Rabe M, Stüber AT, Hering S, Corradini S, Eze C, Marschner S, Belka C, Landry G, Dinkel J, Kurz C. MRI-based ventilation and perfusion imaging to predict radiation-induced pneumonitis in lung tumor patients at a 0.35T MR-Linac. Radiother Oncol 2024; 199:110468. [PMID: 39111637 DOI: 10.1016/j.radonc.2024.110468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 07/10/2024] [Accepted: 07/31/2024] [Indexed: 08/12/2024]
Abstract
BACKGROUND AND PURPOSE Radiation-induced pneumonitis (RP), diagnosed 6-12 weeks after treatment, is a complication of lung tumor radiotherapy. So far, clinical and dosimetric parameters have not been reliable in predicting RP. We propose using non-contrast enhanced magnetic resonance imaging (MRI) based functional parameters acquired over the treatment course for patient stratification for improved follow-up. MATERIALS AND METHODS 23 lung tumor patients received MR-guided hypofractionated stereotactic body radiation therapy at a 0.35T MR-Linac. Ventilation- and perfusion-maps were generated from 2D-cine MRI-scans acquired after the first and last treatment fraction (Fx) using non-uniform Fourier decomposition. The relative differences in ventilation and perfusion between last and first Fx in three regions (planning target volume (PTV), lung volume receiving more than 20Gy (V20) excluding PTV, whole tumor-bearing lung excluding PTV) and three dosimetric parameters (mean lung dose, V20, mean dose to the gross tumor volume) were investigated. Univariate receiver operating characteristic curve - area under the curve (ROC-AUC) analysis was performed (endpoint RP grade≥1) using 5000 bootstrapping samples. Differences between RP and non-RP patients were tested for statistical significance with the non-parametric Mann-Whitney U test (α=0.05). RESULTS 14/23 patients developed RP of grade≥1 within 3 months. The dosimetric parameters showed no significant differences between RP and non-RP patients. In contrast, the functional parameters, especially the relative ventilation difference in the PTV, achieved a p-value<0.05 and an AUC value of 0.84. CONCLUSION MRI-based functional parameters extracted from 2D-cine MRI-scans were found to be predictive of RP development in lung tumor patients.
Collapse
Affiliation(s)
- Rabea Klaar
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, 81377, Germany; Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany.
| | - Moritz Rabe
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| | - Anna Theresa Stüber
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, 81377, Germany; Department of Statistics, LMU Munich, Munich, 80539, Germany; Munich Center for Machine Learning (MCML), Munich, 80539, Germany
| | - Svenja Hering
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| | - Chukwuka Eze
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| | - Sebastian Marschner
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| | - Claus Belka
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany; German Cancer Consortium (DKTK), partner site Munich, a partnership between DKFZ and LMU University Hospital Munich, Munich, 80336, Germany; Bavarian Cancer Research Center (BZKF), Munich, 80336, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| | - Julien Dinkel
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, 81377, Germany; Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, 81377, Germany
| |
Collapse
|
4
|
Midroni J, Salunkhe R, Liu Z, Chow R, Boldt G, Palma D, Hoover D, Vinogradskiy Y, Raman S. Incorporation of Functional Lung Imaging Into Radiation Therapy Planning in Patients With Lung Cancer: A Systematic Review and Meta-Analysis. Int J Radiat Oncol Biol Phys 2024; 120:370-408. [PMID: 38631538 PMCID: PMC11580018 DOI: 10.1016/j.ijrobp.2024.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 03/27/2024] [Accepted: 04/02/2024] [Indexed: 04/19/2024]
Abstract
Our purpose was to provide an understanding of current functional lung imaging (FLI) techniques and their potential to improve dosimetry and outcomes for patients with lung cancer receiving radiation therapy (RT). Excerpta Medica dataBASE (EMBASE), PubMed, and Cochrane Library were searched from 1990 until April 2023. Articles were included if they reported on FLI in one of: techniques, incorporation into RT planning for lung cancer, or quantification of RT-related outcomes for patients with lung cancer. Studies involving all RT modalities, including stereotactic body RT and particle therapy, were included. Meta-analyses were conducted to investigate differences in dose-function parameters between anatomic and functional RT planning techniques, as well as to investigate correlations of dose-function parameters with grade 2+ radiation pneumonitis (RP). One hundred seventy-eight studies were included in the narrative synthesis. We report on FLI modalities, dose-response quantification, functional lung (FL) definitions, FL avoidance techniques, and correlations between FL irradiation and toxicity. Meta-analysis results show that FL avoidance planning gives statistically significant absolute reductions of 3.22% to the fraction of well-ventilated lung receiving 20 Gy or more, 3.52% to the fraction of well-perfused lung receiving 20 Gy or more, 1.3 Gy to the mean dose to the well-ventilated lung, and 2.41 Gy to the mean dose to the well-perfused lung. Increases in the threshold value for defining FL are associated with decreases in functional parameters. For intensity modulated RT and volumetric modulated arc therapy, avoidance planning results in a 13% rate of grade 2+ RP, which is reduced compared with results from conventional planning cohorts. A trend of increased predictive ability for grade 2+ RP was seen in models using FL information but was not statistically significant. FLI shows promise as a method to spare FL during thoracic RT, but interventional trials related to FL avoidance planning are sparse. Such trials are critical to understanding the effect of FL avoidance planning on toxicity reduction and patient outcomes.
Collapse
Affiliation(s)
- Julie Midroni
- Temerty Faculty of Medicine, University of Toronto, Toronto, Canada; Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada
| | - Rohan Salunkhe
- Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Zhihui Liu
- Biostatistics, Princess Margaret Cancer Center, Toronto, Canada
| | - Ronald Chow
- Temerty Faculty of Medicine, University of Toronto, Toronto, Canada; Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada
| | - Gabriel Boldt
- London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada
| | - David Palma
- London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada; Ontario Institute for Cancer Research, Toronto, Canada
| | - Douglas Hoover
- London Regional Cancer Program, London Health Sciences Centre, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada
| | - Yevgeniy Vinogradskiy
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, United States of America; Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, United States of America
| | - Srinivas Raman
- Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Canada.
| |
Collapse
|
5
|
Bi S, Yuan Q, Dai Z, Sun X, Wan Sohaimi WFB, Bin Yusoff AL. Advances in CT-based lung function imaging for thoracic radiotherapy. Front Oncol 2024; 14:1414337. [PMID: 39286020 PMCID: PMC11403405 DOI: 10.3389/fonc.2024.1414337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 08/14/2024] [Indexed: 09/19/2024] Open
Abstract
The objective of this review is to examine the potential benefits and challenges of CT-based lung function imaging in radiotherapy over recent decades. This includes reviewing background information, defining related concepts, classifying and reviewing existing studies, and proposing directions for further investigation. The lung function imaging techniques reviewed herein encompass CT-based methods, specifically utilizing phase-resolved four-dimensional CT (4D-CT) or end-inspiratory and end-expiratory CT scans, to delineate distinct functional regions within the lungs. These methods extract crucial functional parameters, including lung volume and ventilation distribution, pivotal for assessing and characterizing the functional capacity of the lungs. CT-based lung ventilation imaging offers numerous advantages, notably in the realm of thoracic radiotherapy. By utilizing routine CT scans, additional radiation exposure and financial burdens on patients can be avoided. This imaging technique also enables the identification of different functional areas of the lung, which is crucial for minimizing radiation exposure to healthy lung tissue and predicting and detecting lung injury during treatment. In conclusion, CT-based lung function imaging holds significant promise for improving the effectiveness and safety of thoracic radiotherapy. Nevertheless, challenges persist, necessitating further research to address limitations and optimize clinical utilization. Overall, this review highlights the importance of CT-based lung function imaging as a valuable tool in radiotherapy planning and lung injury monitoring.
Collapse
Affiliation(s)
- Suyan Bi
- School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Qingqing Yuan
- National Cancer Center/National Clinical Research Center for Cancer/ Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Zhitao Dai
- National Cancer Center/National Clinical Research Center for Cancer/ Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Xingru Sun
- Huizhou Third People's Hospital, Guangzhou Medical University, Huizhou, Guangdong, China
| | - Wan Fatihah Binti Wan Sohaimi
- Department of Nuclear Medicine Radiotherapy and Oncology, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Ahmad Lutfi Bin Yusoff
- Department of Nuclear Medicine Radiotherapy and Oncology, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia
| |
Collapse
|
6
|
Yamamoto T, Kabus S, Bal M, Keall PJ, Moran A, Wright C, Benedict SH, Holland D, Mahaffey N, Qi L, Daly ME. Four-Dimensional Computed Tomography Ventilation Image-Guided Lung Functional Avoidance Radiation Therapy: A Single-Arm Prospective Pilot Clinical Trial. Int J Radiat Oncol Biol Phys 2023; 115:1144-1154. [PMID: 36427643 DOI: 10.1016/j.ijrobp.2022.11.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 10/28/2022] [Accepted: 11/09/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE The primary objective of this prospective pilot trial was to assess the safety and feasibility of lung functional avoidance radiation therapy (RT) with 4-dimensional (4D) computed tomography (CT) ventilation imaging. METHODS AND MATERIALS Patients with primary lung cancer or metastatic disease to the lungs to receive conventionally fractionated RT (CFRT) or stereotactic body RT (SBRT) were eligible. Standard-of-care 4D-CT scans were used to generate ventilation images through image processing/analysis. Each patient required a standard intensity modulated RT plan and ventilation image guided functional avoidance plan. The primary endpoint was the safety of functional avoidance RT, defined as the rate of grade ≥3 adverse events (AEs) that occurred ≤12 months after treatment. Protocol treatment was considered safe if the rates of grade ≥3 pneumonitis and esophagitis were <13% and <21%, respectively for CFRT, and if the rate of any grade ≥3 AEs was <28% for SBRT. Feasibility of functional avoidance RT was assessed by comparison of dose metrics between the 2 plans using the Wilcoxon signed-rank test. RESULTS Between May 2015 and November 2019, 34 patients with non-small cell lung cancer were enrolled, and 33 patients were evaluable (n = 24 for CFRT; n = 9 for SBRT). Median follow-up was 14.7 months. For CFRT, the rates of grade ≥3 pneumonitis and esophagitis were 4.2% (95% confidence interval, 0.1%-21.1%) and 12.5% (2.7%-32.4%). For SBRT, no patients developed grade ≥3 AEs. Compared with the standard plans, the functional avoidance plans significantly (P < .01) reduced the lung dose-function metrics without compromising target coverage or adherence to standard organs at risk constraints. CONCLUSIONS This study, representing one of the first prospective investigations on lung functional avoidance RT, demonstrated that the 4D-CT ventilation image guided functional avoidance RT that significantly reduced dose to ventilated lung regions could be safely administered, adding to the growing body of evidence for its clinical utility.
Collapse
Affiliation(s)
- Tokihiro Yamamoto
- Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California.
| | - Sven Kabus
- Department of Medical Image Processing & Analytics, Philips Research, Hamburg, Germany
| | | | - Paul J Keall
- ACRF Image X Institute, University of Sydney, Sydney, New South Wales, Australia
| | - Angel Moran
- Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California
| | - Cari Wright
- Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California
| | - Stanley H Benedict
- Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California
| | - Devin Holland
- Office of Clinical Research, University of California Davis Comprehensive Cancer Center, Sacramento, California
| | - Nichole Mahaffey
- Office of Clinical Research, University of California Davis Comprehensive Cancer Center, Sacramento, California
| | - Lihong Qi
- Department of Public Health Sciences, University of California, Davis, California
| | - Megan E Daly
- Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California
| |
Collapse
|
7
|
Hoppen L, Sarria GR, Kwok CS, Boda-Heggemann J, Buergy D, Ehmann M, Giordano FA, Fleckenstein J. Dosimetric benefits of adaptive radiation therapy for patients with stage III non-small cell lung cancer. Radiat Oncol 2023; 18:34. [PMID: 36814271 PMCID: PMC9945670 DOI: 10.1186/s13014-023-02222-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 02/06/2023] [Indexed: 02/24/2023] Open
Abstract
BACKGROUND Daily adaptive radiation therapy (ART) of patients with non-small cell lung cancer (NSCLC) lowers organs at risk exposure while maintaining the planning target volume (PTV) coverage. Thus, ART allows an isotoxic approach with increased doses to the PTV that could improve local tumor control. Herein we evaluate daily online ART strategies regarding their impact on relevant dose-volume metrics. METHODS Daily cone-beam CTs (1 × n = 28, 1 × n = 29, 11 × n = 30) of 13 stage III NSCLC patients were converted into synthetic CTs (sCTs). Treatment plans (TPs) were created retrospectively on the first-fraction sCTs (sCT1) and subsequently transferred unaltered to the sCTs of the remaining fractions of each patient (sCT2-n) (IGRT scenario). Two additional TPs were generated on sCT2-n: one minimizing the lung-dose while preserving the D95%(PTV) (isoeffective scenario), the other escalating the D95%(PTV) with a constant V20Gy(lungipsilateral) (isotoxic scenario). RESULTS Compared to the original TPs predicted dose, the median D95%(PTV) in the IGRT scenario decreased by 1.6 Gy ± 4.2 Gy while the V20Gy(lungipsilateral) increased in median by 1.1% ± 4.4%. The isoeffective scenario preserved the PTV coverage and reduced the median V20Gy(lungipsilateral) by 3.1% ± 3.6%. Furthermore, the median V5%(heart) decreased by 2.9% ± 6.4%. With an isotoxic prescription, a median dose-escalation to the gross target volume of 10.0 Gy ± 8.1 Gy without increasing the V20Gy(lungipsilateral) and V5%(heart) was feasible. CONCLUSIONS We demonstrated that even without reducing safety margins, ART can reduce lung-doses, while still reaching adequate target coverage or escalate target doses without increasing ipsilateral lung exposure. Clinical benefits by means of toxicity and local control of both strategies should be evaluated in prospective clinical trials.
Collapse
Affiliation(s)
- Lea Hoppen
- Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
| | - Gustavo R. Sarria
- grid.10388.320000 0001 2240 3300Department of Radiation Oncology, University Hospital Bonn, University of Bonn, Bonn, Germany
| | - Chung S. Kwok
- grid.7700.00000 0001 2190 4373Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Judit Boda-Heggemann
- grid.7700.00000 0001 2190 4373Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Daniel Buergy
- grid.7700.00000 0001 2190 4373Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Michael Ehmann
- grid.7700.00000 0001 2190 4373Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Frank A. Giordano
- grid.7700.00000 0001 2190 4373Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| | - Jens Fleckenstein
- grid.7700.00000 0001 2190 4373Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
| |
Collapse
|
8
|
Huang YS, Chen JLY, Lan HT, Tai MH, Kuo SH, Shih JY, Chang YC. Xenon-Enhanced Ventilation Computed Tomography for Functional Lung Avoidance Radiation Therapy in Patients With Lung Cancer. Int J Radiat Oncol Biol Phys 2023; 115:356-365. [PMID: 36029910 DOI: 10.1016/j.ijrobp.2022.07.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Revised: 06/22/2022] [Accepted: 07/19/2022] [Indexed: 01/14/2023]
Abstract
PURPOSE This phase 2 trial aimed to determine whether xenon-enhanced ventilation computed tomography (XeCT)-guided functional-lung-avoidance radiation therapy could reduce the radiation pneumonitis (RP) rate in patients with lung cancer undergoing definitive chemoradiation therapy. METHODS AND MATERIALS Functional lung ventilation was measured via pulmonary function testing (PFT) and XeCT. A standard plan (SP) without reference to XeCT and a functional-lung-avoidance plan (fAP) optimized for lowering the radiation dose to the functional lung at the guidance of XeCT were designed. Dosimetric parameters and predicted RP risks modeled by biological evaluation were compared between the 2 plans in a treatment planning system (TPS). All patients received the approved fAP. The primary endpoint was the rate of grade ≥2 RP, and the secondary endpoints were the survival outcomes. The study hypothesis was that fAP could reduce the rate of grade ≥2 RP to 12% compared with a 30% historical rate. RESULTS Thirty-six patients were evaluated. Xenon-enhanced total functional lung volumes positively correlated with PFT ventilation parameters (forced vital capacity, P = .012; forced expiratory volume in 1 second, P = .035), whereas they were not correlated with the diffusion capacity parameter. We observed a 17% rate of grade ≥2 RP (6 of 36 patients), which was significantly different (P = .040) compared with the historical control. Compared with the SP, the fAP significantly spared the total ventilated lung, leading to a reduction in predicted grade ≥2 RP (P = .001) by TPS biological evaluation. The median follow-up was 15.2 months. The 1-year local control (LC), disseminated failure-free survival (DFFS), and overall survival (OS) rates were 88%, 66%, and 91%, respectively. The median LC and OS were not reached, and the median DFFS was 24.0 months (95% confidence interval, 15.7-32.3 months). CONCLUSIONS This report of XeCT-guided functional-lung-avoidance radiation therapy provided evidence showing its feasibility in clinical practice. Its benefit should be assessed in a broader multicenter trial setting.
Collapse
Affiliation(s)
- Yu-Sen Huang
- Department of Radiology, National Taiwan University College of Medicine, Taipei, Taiwan; Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan
| | - Jenny Ling-Yu Chen
- Department of Radiology, National Taiwan University College of Medicine, Taipei, Taiwan; Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan
| | - Hao-Ting Lan
- Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan
| | - Mei-Hwa Tai
- Department of Radiology, National Taiwan University College of Medicine, Taipei, Taiwan; Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan
| | - Sung-Hsin Kuo
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Division of Radiation Oncology, Department of Oncology, National Taiwan University Hospital, Taipei, Taiwan
| | - Jin-Yuan Shih
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Yeun-Chung Chang
- Department of Radiology, National Taiwan University College of Medicine, Taipei, Taiwan; Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan.
| |
Collapse
|
9
|
Li S, Liu J, Gao S, Yin Y, Zhang L, Han Y, Zhang X, Li Y, Yan J, Hou Z. CT ventilation image-guided helical Tomotherapy at sparing functional lungs for locally advanced lung cancer: analysis of dose-function metrics and the impact on pulmonary toxicity. Radiat Oncol 2023; 18:6. [PMID: 36624537 PMCID: PMC9830733 DOI: 10.1186/s13014-022-02189-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 12/23/2022] [Indexed: 01/11/2023] Open
Abstract
PURPOSE CT ventilation image (CTVI)-guided radiotherapy that selectively avoids irradiating highly-functional lung regions has potential to reduce pulmonary toxicity. Considering Helical TomoTherapy (HT) has higher modulation capabilities, we investigated the capability and characteristic of HT at sparing functional lungs for locally advanced lung cancer. METHODS AND MATERIALS Pretreatment 4DCT scans were carried out for 17 patients. Local lung volume expansion (or contraction) during inspiration is related to the volume change at a given lung voxel and is used as a surrogate for ventilation. The ventilation maps were generated from two sets of CT images (peak-exhale and peak-inhale) by deformable registration and a Jacobian-based algorithm. Each ventilation map was normalized to percentile images. Six plans were designed for each patient: one anatomical plan without ventilation map and five functional plans incorporating ventilation map which designed to spare varying degrees of high-functional lungs that were defined as the top 10%, 20%, 30%, 40%, and 50% of the percentile ventilation ranges, respectively. The dosimetric and evaluation factors were recorded regarding planning target volume (PTV) and other organs at risk (OARs), with particular attention to the dose delivered to total lung and functional lungs. An established dose-function-based normal tissue complication probability (NTCP) model was used to estimate risk of radiation pneumonitis (RP) for each scenario. RESULTS Patients were divided into a benefit group (8 patients) and a non-benefit group (9 patients) based on whether the RP-risk of functional plan was lower than that of anatomical plan. The distance between high-ventilated region and PTV, as well as tumor volume had significant differences between the two groups (P < 0.05). For patients in the benefit group, the mean value of fV5, fV10, fV20, and fMLD (functional V5, V10, V20, and mean lung dose, respectively) were significantly lower starting from top 30% functional plan than in anatomical plan (P < 0.05). With expand of avoidance region in functional plans, the dose coverage of PTV is not sacrificed (P > 0.05) but at the cost of increased dose received by OARs. CONCLUSION Ventilation image-guided HT plans can reduce the dose received by highly-functional lung regions with a range up to top 50% ventilated area. The spatial distribution of ventilation and tumor size were critical factors to better select patients who could benefit from the functional plan.
Collapse
Affiliation(s)
- Shuangshuang Li
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Juan Liu
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Shanbao Gao
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Yicai Yin
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Ling Zhang
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Yongchao Han
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Xishun Zhang
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Yuanyuan Li
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Jing Yan
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| | - Zhen Hou
- grid.412676.00000 0004 1799 0784The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210000 Jiangsu China
| |
Collapse
|
10
|
Zhou PX, Zhang SX. Functional lung imaging in thoracic tumor radiotherapy: Application and progress. Front Oncol 2022; 12:908345. [PMID: 36212454 PMCID: PMC9544588 DOI: 10.3389/fonc.2022.908345] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/17/2022] [Indexed: 12/12/2022] Open
Abstract
Radiotherapy plays an irreplaceable and unique role in treating thoracic tumors, but the occurrence of radiation-induced lung injury has limited the increase in tumor target doses and has influenced patients' quality of life. However, the introduction of functional lung imaging has been incorporating functional lungs into radiotherapy planning. The design of the functional lung protection plan, while meeting the target dose requirements and dose limitations of the organs at risk (OARs), minimizes the radiation dose to the functional lung, thus reducing the occurrence of radiation-induced lung injury. In this manuscript, we mainly reviewed the lung ventilation or/and perfusion functional imaging modalities, application, and progress, as well as the results based on the functional lung protection planning in thoracic tumors. In addition, we also discussed the problems that should be explored and further studied in the practical application based on functional lung radiotherapy planning.
Collapse
Affiliation(s)
- Pi-Xiao Zhou
- Radiotherapy Center, Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou, China
- Department of Oncology, The First People's Hospital of Changde City, Changde, China
| | - Shu-Xu Zhang
- Radiotherapy Center, Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou, China
| |
Collapse
|
11
|
Ren G, Li B, Lam SK, Xiao H, Huang YH, Cheung ALY, Lu Y, Mao R, Ge H, Kong FM(S, Ho WY, Cai J. A Transfer Learning Framework for Deep Learning-Based CT-to-Perfusion Mapping on Lung Cancer Patients. Front Oncol 2022; 12:883516. [PMID: 35847874 PMCID: PMC9283770 DOI: 10.3389/fonc.2022.883516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 06/02/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose Deep learning model has shown the feasibility of providing spatial lung perfusion information based on CT images. However, the performance of this method on lung cancer patients is yet to be investigated. This study aims to develop a transfer learning framework to evaluate the deep learning based CT-to-perfusion mapping method specifically on lung cancer patients. Methods SPECT/CT perfusion scans of 33 lung cancer patients and 137 non-cancer patients were retrospectively collected from two hospitals. To adapt the deep learning model on lung cancer patients, a transfer learning framework was developed to utilize the features learned from the non-cancer patients. These images were processed to extract features from three-dimensional CT images and synthesize the corresponding CT-based perfusion images. A pre-trained model was first developed using a dataset of patients with lung diseases other than lung cancer, and subsequently fine-tuned specifically on lung cancer patients under three-fold cross-validation. A multi-level evaluation was performed between the CT-based perfusion images and ground-truth SPECT perfusion images in aspects of voxel-wise correlation using Spearman’s correlation coefficient (R), function-wise similarity using Dice Similarity Coefficient (DSC), and lobe-wise agreement using mean perfusion value for each lobe of the lungs. Results The fine-tuned model yielded a high voxel-wise correlation (0.8142 ± 0.0669) and outperformed the pre-trained model by approximately 8%. Evaluation of function-wise similarity indicated an average DSC value of 0.8112 ± 0.0484 (range: 0.6460-0.8984) for high-functional lungs and 0.8137 ± 0.0414 (range: 0.6743-0.8902) for low-functional lungs. Among the 33 lung cancer patients, high DSC values of greater than 0.7 were achieved for high functional volumes in 32 patients and low functional volumes in all patients. The correlations of the mean perfusion value on the left upper lobe, left lower lobe, right upper lobe, right middle lobe, and right lower lobe were 0.7314, 0.7134, 0.5108, 0.4765, and 0.7618, respectively. Conclusion For lung cancer patients, the CT-based perfusion images synthesized by the transfer learning framework indicated a strong voxel-wise correlation and function-wise similarity with the SPECT perfusion images. This suggests the great potential of the deep learning method in providing regional-based functional information for functional lung avoidance radiation therapy.
Collapse
Affiliation(s)
- Ge Ren
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Bing Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
- Department of Radiotherapy, Affiliated Cancer Hospital of Zhengzhou University/Henan Cancer Hospital, Zhengzhou, China
| | - Sai-kit Lam
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Haonan Xiao
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Yu-Hua Huang
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
| | - Andy Lai-yin Cheung
- Department of Clinical Oncology, Queen Mary Hospital, Hong Kong, Hong Kong SAR, China
| | - Yufei Lu
- Department of Radiotherapy, Affiliated Cancer Hospital of Zhengzhou University/Henan Cancer Hospital, Zhengzhou, China
| | - Ronghu Mao
- Department of Radiotherapy, Affiliated Cancer Hospital of Zhengzhou University/Henan Cancer Hospital, Zhengzhou, China
| | - Hong Ge
- Department of Radiotherapy, Affiliated Cancer Hospital of Zhengzhou University/Henan Cancer Hospital, Zhengzhou, China
| | - Feng-Ming (Spring) Kong
- Department of Clinical Oncology, Queen Mary Hospital, Hong Kong, Hong Kong SAR, China
- Department of Clinical Oncology, The University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Wai-yin Ho
- Department of Nuclear Medicine, Queen Mary Hospital, Hong Kong, Hong Kong SAR, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China
- *Correspondence: Jing Cai,
| |
Collapse
|
12
|
Nyeng TB, Møller DS, Farr K, Kramer S, Khalil AA, Grau C, Hoffmann L. A comparison of two methods for segmentation of functional volumes in radiotherapy planning of lung cancer patients. Acta Oncol 2021; 60:353-360. [PMID: 33522851 DOI: 10.1080/0284186x.2021.1877811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
BACKGROUND In radiotherapy (RT) of lung cancer, dose to functional lung (FL) volumes segmented with two different methods (perfusion SPECT (Q-SPECT) and 4D-CT (4D) ventilation (V)) have been shown to correlate with the incidence of radiation pneumonitis (RP). This study aims to compare the FL volumes identified by both methods. MATERIAL AND METHODS Thirty lung cancer patients had a 4D and Q-SPECT prior to treatment. Seventeen of these patients also had a ventilation SPECT (V-SPECT). FL sub-volumes were segmented automatically, using cut-off values. The volumes were compared in terms of overlap fraction (OF) relative to the minimal volume, and intersection fraction (IF) of the FL volume relative to the total lung volume (VLung). RESULTS Cut-off values suggested in literature for Q-SPECT and 4D-V resulted in volumes differing in size by a median 18% [6%;31%], and a median OF and IF of 0.48 [0.23;0.70] and 0.09 [0.02;0.25], respectively. Segmenting volumes of comparable size of about 1/3 of VLung (FL-m(1/3), m = method) resulted in a median OF and IF of 0.43 [0.23;0.58] and 0.12 [0.06;0.19], respectively. Twenty-five patients (83%) had a reasonable overlap between FL-Q(1/3) and FL-4D-V(1/3) volumes, with OF values above 0.33. IF increased significantly (p = .036) compared to using fixed cut-off values. Similarly, volumes of comparable size of about 1/3 VLung were produced for V-SPECT, and FL-Q(1/3), FL-V(1/3), and FL-4D-V(1/3) were compared. The overlaps and intersections of FL-V(1/3) with FL-Q(1/3) volumes were significantly (p<.001) larger than the corresponding overlaps and intersections of FL-Q(1/3) with FL-4D(1/3) and FL-V(1/3) with FL-4D(1/3). CONCLUSION The Q-SPECT and 4D-V methods do not segment entirely the same FL volumes. A reasonable overlap of the volumes along with the findings of other studies that both correlate to RP incidence, suggests that a combination of both volumes, e.g. using the IF, may be useful in RT treatment planning.
Collapse
Affiliation(s)
- T. B. Nyeng
- Department of Oncology, Section for Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - D. S. Møller
- Department of Oncology, Section for Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - K. Farr
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - S. Kramer
- Department of Nuclear Medicine & PET-Centre, Aarhus University Hospital, Aarhus, Denmark
| | - A. A. Khalil
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - C. Grau
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - L. Hoffmann
- Department of Oncology, Section for Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
13
|
Shao W, Patton TJ, Gerard SE, Pan Y, Reinhardt JM, Durumeric OC, Bayouth JE, Christensen GE. N-Phase Local Expansion Ratio for Characterizing Out-of-Phase Lung Ventilation. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2025-2034. [PMID: 31899418 PMCID: PMC7316305 DOI: 10.1109/tmi.2019.2963083] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Out-of-phase ventilation occurs when local regions of the lung reach their maximum or minimum volumes at breathing phases other than the global end inhalation or exhalation phases. This paper presents the N-phase local expansion ratio (LER N ) as a surrogate for lung ventilation. A common approach to estimate lung ventilation is to use image registration to align the end exhalation and inhalation 3DCT images and then analyze the resulting correspondence map. This 2-phase local expansion ratio (LER2) is limited because it ignores out-of-phase ventilation and thus may underestimate local lung ventilation. To overcome this limitation, LER N measures the maximum ratio of local expansion and contraction over the entire breathing cycle. Comparing LER2 to LER N provides a means for detecting and characterizing locations of the lung that experience out-of-phase ventilation. We present a novel in-phase/out-of-phase ventilation (IOV) function plot to visualize and measure the amount of high-function IOV that occurs during a breathing cycle. Treatment planning 4DCT scans collected during coached breathing from 32 human subjects with lung cancer were analyzed in this study. Results show that out-of-phase breathing occurred in all subjects and that the spatial distribution of out-of-phase ventilation varied from subject to subject. For the 32 subjects analyzed, 50% of the out-of-phase regions on average were mislabeled as low-function by LER2 (high-function threshold of 1.1, IOV threshold of 1.05). 4DCT and Xenon-enhanced CT of four sheep showed that LER8 is more accurate than LER2 for measuring lung ventilation.
Collapse
|
14
|
Wallat EM, Flakus MJ, Wuschner AE, Shao W, Christensen GE, Reinhardt JM, Baschnagel AM, Bayouth JE. Modeling the impact of out‐of‐phase ventilation on normal lung tissue response to radiation dose. Med Phys 2020; 47:3233-3242. [DOI: 10.1002/mp.14146] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 02/14/2020] [Accepted: 03/09/2020] [Indexed: 12/24/2022] Open
Affiliation(s)
- Eric M. Wallat
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - Mattison J. Flakus
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - Antonia E. Wuschner
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - Wei Shao
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA 52242 USA
| | - Gary E. Christensen
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA 52242 USA
| | - Joseph M. Reinhardt
- Department of Biomedical Engineering University of Iowa Iowa City IA 52242 USA
| | - Andrew M. Baschnagel
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| | - John E. Bayouth
- Department of Human Oncology University of Wisconsin‐Madison Madison WI 53705 USA
| |
Collapse
|
15
|
Evaluation of the effect of user-guided deformable image registration of thoracic images on registration accuracy among users. Med Dosim 2020; 45:206-212. [PMID: 32014379 DOI: 10.1016/j.meddos.2019.12.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 11/22/2019] [Accepted: 12/10/2019] [Indexed: 11/20/2022]
Abstract
User-guided deformable image registration (DIR) has allowed users to actively participate in the DIR process and is expected to improve DIR accuracy. The purpose of this study was to evaluate the time required for and effect of user-guided DIR on registration accuracy for thoracic images among users. In this study, 4-dimensional computed tomographic images of 10 thoracic cancer patients were used. The dataset for these patients was provided by DIR-Lab (www.dir-lab.com) and included a coordinate list of anatomical landmarks (300 bronchial bifurcations). Four medical physicists from different institutions performed DIR between peak-inhale and peak-exhale images with/without the user-guided DIR tool, Reg Refine, implemented in MIM Maestro (MIM software, Cleveland, OH). DIR accuracy was quantified by using target registration errors (TREs) for 300 anatomical landmarks in each patient. The average TREs with user-guided DIR in the 10 images by the 4 medical physicists were 1.48, 1.80, 3.46, and 3.55 mm, respectively, whereas the TREs without user-guided DIR were 3.28, 3.45, 3.56, and 3.28 mm, respectively. The average times taken by the 4 physicists to use the user-guided DIR were 10.0, 6.7, 7.1, and 8.0 min, respectively. This study demonstrated that user-guided DIR can improve DIR accuracy and requires only a moderate amount of time (<10 min). However, 2 of the 4 users did not show much improvement in DIR accuracy, which indicated the necessity of training prior to use of user-guided DIR.
Collapse
|
16
|
Vicente E, Modiri A, Yu KC, Wibowo H, Yan Y, Timmerman R, Sawant A. Accounting for respiratory motion in small serial structures during radiotherapy planning: proof of concept in virtual bronchoscopy-guided lung functional avoidance radiotherapy. Phys Med Biol 2019; 64:225011. [PMID: 31665703 DOI: 10.1088/1361-6560/ab52a1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Respiratory motion management techniques in radiotherapy (RT) planning are primarily focused on maintaining tumor target coverage. An inadequately addressed need is accounting for motion in dosimetric estimations in smaller serial structures. Accurate dose estimations in such structures are more sensitive to motion because respiration can cause them to move completely in or out of a high dose-gradient field. In this work, we study three motion management strategies (m1-m3) to find an accurate method to estimate the dosimetry in airways. To validate these methods, we generated a 'ground truth' digital breathing model based on a 4DCT scan from a lung stereotactic ablative radiotherapy (SAbR) patient. We simulated 225 breathing cycles with ±10% perturbations in amplitude, respiratory period, and time per respiratory phase. A high-resolution breath-hold CT (BHCT) was also acquired and used with a research virtual bronchoscopy software to autosegment 239 airways. Contours for planning target volume (PTV) and organs at risk (OARs) were defined on the maximum intensity projection of the 4DCT (CTMIP) and transferred to the average of the 10 4DCT phases (CTAVG). To design the motion management methods, the RT plan was recreated using different images and structure definitions. Methods m1 and m2 recreated the plan using the CTAVG image. In method m1, airways were deformed to the CTAVG. In m2, airways were deformed to each of the 4DCT phases, and union structures were transferred onto the CTAVG. In m3, the RT plan was recreated on each of the 10 phases, and the dose distribution from each phase was deformed to the BHCT and summed. Dose errors (mean [min, max]) in airways were: m1: 21% (0.001%, 93%); m2: 45% (0.1%, 179%); and m3: 4% (0.006%, 14%). Our work suggests that accurate dose estimation in moving small serial structures requires customized motion management techniques (like m3 in this work) rather than current clinical and investigational approaches.
Collapse
Affiliation(s)
- Esther Vicente
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD 21201, United States of America. Author to whom correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
17
|
Alaswad M, Kleefeld C, Foley M. Optimal tumour control for early-stage non-small-cell lung cancer: A radiobiological modelling perspective. Phys Med 2019; 66:55-65. [DOI: 10.1016/j.ejmp.2019.09.074] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 09/06/2019] [Accepted: 09/08/2019] [Indexed: 12/25/2022] Open
|
18
|
Matuszak MM, Kashani R, Green M, Lee C, Cao Y, Owen D, Jolly S, Mierzwa M. Functional Adaptation in Radiation Therapy. Semin Radiat Oncol 2019; 29:236-244. [PMID: 31027641 DOI: 10.1016/j.semradonc.2019.02.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The promise of adaptive therapy to improve outcomes in radiation oncology has been an area of interest and research in the community for many years. One of the sources of data that can be used to drive adaptive therapy is functional information about the tumor or normal tissues. This avenue of adaptation includes many potential sources of data including global markers and functional imaging. Global markers can be assessments derived from blood measurements, patient functional testing, and circulating tumor material and functional imaging data comprises spatial physiological information from various imaging studies such as positron emission tomography, magnetic resonance imaging, and single photon emission computed tomography. The goal of functional adaptation is to use these functional data to adapt radiation therapy to improve patient outcomes. While functional adaptation holds a lot of promise, there are challenges such as quantifying and minimizing uncertainties, streamlining clinical implementation, determining the ideal way to incorporate information within treatment plan optimization, and proving the clinical benefit through trials. This paper will discuss the types of functional information currently being used for adaptation, highlight several areas where functional adaptation has been studied, and introduce some of the barriers to more widespread clinical implementation.
Collapse
Affiliation(s)
- Martha M Matuszak
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI.
| | - Rojano Kashani
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Michael Green
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Choonik Lee
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Shruti Jolly
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| | - Michelle Mierzwa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
| |
Collapse
|
19
|
Vinogradskiy Y. CT-based ventilation imaging in radiation oncology. BJR Open 2019; 1:20180035. [PMID: 33178925 PMCID: PMC7592480 DOI: 10.1259/bjro.20180035] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 01/28/2019] [Accepted: 03/11/2019] [Indexed: 11/06/2022] Open
Abstract
A form of lung function imaging is emerging that uses phase-resolved four-dimensional CT (4DCT or breath-hold CT) images along with image processing techniques to generate lung function maps that provide a surrogate of lung ventilation. CT-based ventilation (referred to as CT-ventilation) research has gained momentum in Radiation Oncology because many lung cancer patients undergo four-dimensional CT simulation as part of the standard treatment planning process. Therefore, generating CT-ventilation images provides functional information without burdening the patient with an extra imaging procedure. CT-ventilation has progressed from an image processing calculation methodology, to validation efforts, to retrospective demonstration of clinical utility in Radiation Oncology. In particular, CT-ventilation has been proposed for two main clinical applications: functional avoidance radiation therapy and thoracic dose-response assessment. The idea of functional avoidance radiation therapy is to preferentially spare functional portions of the lung (as measured by CT-ventilation) during radiation therapy with the hypothesis that reducing dose to functional portions of the lung will lead to reduced rates of radiation-related thoracic toxicity. The idea of imaging-based dose-response assessment is to evaluate pre- to post-treatment CT-ventilation-based imaging changes. The hypothesis is that early, imaging-change-based response can be an early predictor of subsequent thoracic toxicity. Based on the retrospective evidence, the clinical applications of CT-ventilation have progressed from the retrospective setting to on-going prospective clinical trials. This review will cover basic CT-ventilation calculation methodologies, validation efforts, presentation of clinical applications, summarize on-going clinical trials, review potential uncertainties and shortcomings of CT-ventilation, and discuss future directions of CT-ventilation research.
Collapse
Affiliation(s)
- Yevgeniy Vinogradskiy
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO
| |
Collapse
|
20
|
Myziuk N, Guerrero T, Sakthivel G, Solis D, Nair G, Guerra R, Castillo E. Pulmonary blood mass dynamics on 4DCT during tidal breathing. ACTA ACUST UNITED AC 2019; 64:045014. [DOI: 10.1088/1361-6560/aaff7b] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|