1
|
Talebi AS, Mehnati P, Rajabi H, Rezaei H, Geramifar P. Precision individual dosimetry in Yttrium-90 transarterial radioembolization in the presence of Au nanoparticles. Radiat Phys Chem Oxf Engl 1993 2024; 222:111888. [DOI: 10.1016/j.radphyschem.2024.111888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2025]
|
2
|
Kim TP, Gandhi RT, Tolakanahalli R, Herrera R, Chuong MD, Gutierrez AN, Alvarez D. Establishing Updated Safety Standards for Independent 99mTc-MAA SPECT/CT Treatment Planning in Radioembolization. Int J Radiat Oncol Biol Phys 2024; 119:1285-1296. [PMID: 38925768 DOI: 10.1016/j.ijrobp.2023.12.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 12/08/2023] [Accepted: 12/30/2023] [Indexed: 06/28/2024]
Abstract
PURPOSE Significant improvements within radioembolization imaging and dosimetry permit the development of an accurate and personalized pretreatment plan using technetium 99m-labeled macroaggregated albumin (99mTc-MAA) and single-photon emission computed tomography (SPECT) combined with anatomical CT (SPECT/CT). Despite these potential advantages, the clinical transition to pretreatment protocols with SPECT/CT is hindered by their unknown safety constraints. This study aimed to address this issue by establishing novel dose limits for 99mTc-MAA SPECT/CT to enable quantitative pretreatment planning. METHODS AND MATERIALS Stratification criteria to determine images most viable for dosimetry analysis were created from a cohort of 85 patients. SPECT/CT, cone beam CT, and activity calculations derived from the local deposition method were used to create an accurate pretreatment protocol. Planar and SPECT/CT images were compared using linear regression and modified Bland-Altman analyses to convert accepted planar dose limits to SPECT/CT. To validate these new dose limits, activity calculations based on SPECT/CT were compared with those calculated with the body surface area and planar methods for three treatment plans. RESULTS A total of 38 of 85 patients were deemed viable for dosimetry analysis. SPECT yielded greater lung shunt fractions (LSFs) than planar imaging when LSFs were <4.89%, whereas SPECT yielded lower LSFs than planar imaging when LSFs were >4.89%. Planar to SPECT/CT dose conversions were 0.76×, 0.70×, and 0.55× for the whole liver, normal liver, and lungs, respectively. Patients with SPECT LSFs ≤4.89% were safely treated with the direct application of planar lung dose limits. Activity calculations with the newly established SPECT/CT dose limits were greater than those of the body surface area method by a median range of 33.1% to 61.9% and were lower than planar-based activity calculations by a median range of 12.5% to 13.7% for the whole liver and by 29.4% to 32.2% for the normal liver. CONCLUSIONS This study demonstrated a safe method for translating dose limits from 99mTc-MAA planar imaging to SPECT/CT. A robust pretreatment protocol was further developed guided by the current knowledge in the field. Established SPECT/CT dose limits safely treated 97.5% of patients and permitted the application of independent pretreatment planning with 99mTc-MAA SPECT/CT.
Collapse
Affiliation(s)
| | - Ripal T Gandhi
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida; Interventional Radiology Department, Miami Cardiac and Vascular Institute, Miami, Florida
| | | | - Robert Herrera
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| | - Michael D Chuong
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| | | | - Diane Alvarez
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| |
Collapse
|
3
|
Kim TP, Enger SA. Characterizing the voxel-based approaches in radioembolization dosimetry with reDoseMC. Med Phys 2024; 51:4007-4027. [PMID: 38703394 DOI: 10.1002/mp.17054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/15/2024] [Accepted: 02/20/2024] [Indexed: 05/06/2024] Open
Abstract
BACKGROUND Yttrium-90 (90 Y $^{90}{\rm {Y}}$ ) represents the primary radioisotope used in radioembolization procedures, while holmium-166 (166 Ho $^{166}{\rm {Ho}}$ ) is hypothesized to serve as a viable substitute for90 Y $^{90}{\rm {Y}}$ due to its comparable therapeutic potential and improved quantitative imaging. Voxel-based dosimetry for these radioisotopes relies on activity images obtained through PET or SPECT and dosimetry methods, including the voxel S-value (VSV) and the local deposition method (LDM). However, the evaluation of the accuracy of absorbed dose calculations has been limited by the use of non-ideal reference standards and investigations restricted to the liver. The objective of this study was to expand upon these dosimetry characterizations by investigating the impact of image resolutions, voxel sizes, target volumes, and tissue materials on the accuracy of90 Y $^{90}{\rm {Y}}$ and166 Ho $^{166}{\rm {Ho}}$ dosimetry techniques. METHODS A specialized radiopharmaceutical dosimetry software called reDoseMC was developed using the Geant4 Monte Carlo toolkit and validated by benchmarking the generated90 Y $^{90}{\rm {Y}}$ kernels with published data. The decay spectra of both90 Y $^{90}{\rm {Y}}$ and166 Ho $^{166}{\rm {Ho}}$ were also compared. Multiple VSV kernels were generated for the liver, lungs, soft tissue, and bone for isotropic voxel sizes of 1 mm, 2 mm, and 4 mm. Three theoretical phantom setups were created with 20 or 40 mm activity and mass density inserts for the same three voxel sizes. To replicate the limited spatial resolutions present in PET and SPECT images, image resolutions were modeled using a 3D Gaussian kernel with a Full Width at Half Maximum (FWHM) ranging from 0 to 16 mm and with no added noise. The VSV and LDM dosimetry methods were evaluated by characterizing their respective kernels and analyzing their absorbed dose estimates calculated on theoretical phantoms. The ground truth for these estimations was calculated using reDoseMC. RESULTS The decay spectra obtained through reDoseMC showed less than a 1% difference when compared to previously published experimental data for energies below 1.9 MeV in the case of90 Y $^{90}{\rm {Y}}$ and less than 1% for energies below 1.5 MeV for166 Ho $^{166}{\rm {Ho}}$ . Additionally, the validation kernels for90 Y $^{90}{\rm {Y}}$ VSV exhibited results similar to those found in published Monte Carlo codes, with source dose depositions having less than a 3% error margin. Resolution thresholds (FWHM thresh s ${\rm {FWHM}}_\mathrm{thresh}{\rm {s}}$ ), defined as resolutions that resulted in similar dose estimates between the LDM and VSV methods, were observed for90 Y $^{90}{\rm {Y}}$ . They were 1.5 mm for bone, 2.5 mm for soft tissue and liver, and 8.5 mm for lungs. For166 Ho $^{166}{\rm {Ho}}$ , the accuracy of absorbed dose deposition was found to be dependent on the contributions of absorbed dose from photons. Volume errors due to variations in voxel size impacted the final dose estimates. Larger target volumes yielded more accurate mean doses than smaller volumes. For both radioisotopes, the radial dose profiles for the VSV and LDM approximated but never matched the reference standard. CONCLUSIONS reDoseMC was developed and validated for radiopharmaceutical dosimetry. The accuracy of voxel-based dosimetry was found to vary widely with changes in image resolutions, voxel sizes, chosen target volumes, and tissue material; hence, the standardization of dosimetry protocols was found to be of great importance for comparable dosimetry analysis.
Collapse
Affiliation(s)
- Taehyung Peter Kim
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Québec, Canada
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montréal, Québec, Canada
| | - Shirin A Enger
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Québec, Canada
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montréal, Québec, Canada
| |
Collapse
|
4
|
Mee SF, Polan DF, Dewaraja YK, Cuneo KC, Gemmete JJ, Evans JR, Lawrence TS, Dow JS, Mikell JK. Stereotactic body radiation therapy (SBRT) following Yttrium-90 ( 90Y) selective internal radiation therapy (SIRT): a feasibility planning study using 90Y delivered dose. Phys Med Biol 2023; 68:065003. [PMID: 36780696 PMCID: PMC10001703 DOI: 10.1088/1361-6560/acbbb5] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 02/13/2023] [Indexed: 02/15/2023]
Abstract
Objective.90Y selective internal radiation therapy (SIRT) treatment of hepatocellular carcinoma (HCC) can potentially underdose lesions, as identified on post-therapy PET/CT imaging. This study introduces a methodology and explores the feasibility for selectively treating SIRT-underdosed HCC lesions, or lesion subvolumes, with stereotactic body radiation therapy (SBRT) following post-SIRT dosimetry.Approach. We retrospectively analyzed post-treatment PET/CT images of 20 HCC patients after90Y SIRT. Predicted tumor response from SIRT was quantified based on personalized post-therapy dosimetry and corresponding response models. Predicted non-responding tumor regions were then targeted with a hypothetical SBRT boost plan using a framework for selecting eligible tumors and tumor subregions. SBRT boost plans were compared to SBRT plans targeting all tumors irrespective of SIRT dose with the same prescription and organ-at-risk (OAR) objectives. The potential benefit of SIRT followed by a SBRT was evaluated based on OAR dose and predicted toxicity compared to the independent SBRT treatment.Main results. Following SIRT, 14/20 patients had at least one predicted non-responding tumor considered eligible for a SBRT boost. When comparing SBRT plans, 10/14 (71%) SBRTboostand 12/20 (60%) SBRTaloneplans were within OAR dose constraints. For three patients, SBRTboostplans were within OAR constraints while SBRTaloneplans were not. Across the 14 eligible patients, SBRTboostplans had significantly less dose to the healthy liver (decrease in mean dose was on average ± standard deviation, 2.09 Gy ± 1.99 Gy, ) and reduced the overall targeted PTV volume (39% ± 21%) compared with SBRTalone.Significance. A clinical methodology for treating HCC using a synergized SIRT and SBRT approach is presented, demonstrating that it could reduce normal tissue toxicity risk in a majority of our retrospectively evaluated cases. Selectively targeting SIRT underdosed HCC lesions, or lesion subvolumes, with SBRT could improve tumor control and patient outcomes post-SIRT and allow SIRT to function as a target debulking tool for cases when SBRT is not independently feasible.
Collapse
Affiliation(s)
- Stephen F Mee
- Department of Radiology, University of Michigan, Ann Arbor, MI, United States of America.,School of Medicine, Wayne State University, Detroit, MI, United States of America
| | - Daniel F Polan
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America
| | - Yuni K Dewaraja
- Department of Radiology, University of Michigan, Ann Arbor, MI, United States of America
| | - Kyle C Cuneo
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America
| | - Joseph J Gemmete
- Department of Radiology, University of Michigan, Ann Arbor, MI, United States of America
| | - Joseph R Evans
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America
| | - Theodore S Lawrence
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America
| | - Janell S Dow
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America
| | - Justin K Mikell
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America
| |
Collapse
|
5
|
Craig AJ, Murray I, Denis-Bacelar AM, Rojas B, Gear JI, Hossen L, Maenhout A, Khan N, Flux GD. Comparison of 90Y SIRT predicted and delivered absorbed doses using a PSF conversion method. Phys Med 2021; 89:1-10. [PMID: 34339928 PMCID: PMC8501309 DOI: 10.1016/j.ejmp.2021.07.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 06/23/2021] [Accepted: 07/19/2021] [Indexed: 12/24/2022] Open
Abstract
PURPOSE The aims of this study were to develop and apply a method to correct for the differences in partial volume effects of pre-therapy Technetium-99 m (99mTc)-MAA SPECT and post-therapy Yttrium-90 (90Y) bremsstrahlung SPECT imaging in selective internal radiation therapy, and to use this method to improve quantitative comparison of predicted and delivered 90Y absorbed doses. METHODS The spatial resolution of 99mTc SPECT data was converted to that of 90Y SPECT data using a function calculated from 99mTc and 90Y point spread functions. This resolution conversion method (RCM) was first applied to 99mTc and 90Y SPECT phantom data to validate the method, and then to clinical data to assess the power of 99mTc SPECT imaging to predict the therapeutic absorbed dose. RESULTS The maximum difference between absorbed doses to phantom spheres was 178%. This was reduced to 27% after the RCM was applied. The clinical data demonstrated differences within 38% for mean absorbed doses delivered to the normal liver, which were reduced to 20% after application of the RCM. Analysis of clinical data showed that therapeutic absorbed doses delivered to tumours greater than 100 cm3 were predicted to within 52%, although there were differences of up to 210% for smaller tumours, even after the RCM was applied. CONCLUSIONS The RCM was successfully verified using phantom data. Analysis of the clinical data established that the 99mTc pre-therapy imaging was predictive of the 90Y absorbed dose to the normal liver to within 20%, but had poor predictability for tumours smaller than 100 cm3.
Collapse
Affiliation(s)
- Allison J. Craig
- Joint Department of Physics, Royal Marsden NHSFT, Sutton, United Kingdom,The Institute of Cancer Research, London, United Kingdom,Corresponding author.
| | - Iain Murray
- Joint Department of Physics, Royal Marsden NHSFT, Sutton, United Kingdom,The Institute of Cancer Research, London, United Kingdom
| | | | - Bruno Rojas
- Joint Department of Physics, Royal Marsden NHSFT, Sutton, United Kingdom,The Institute of Cancer Research, London, United Kingdom
| | - Jonathan I. Gear
- Joint Department of Physics, Royal Marsden NHSFT, Sutton, United Kingdom,The Institute of Cancer Research, London, United Kingdom
| | - Lucy Hossen
- Royal Brompton & Harefield NHSFT, London, United Kingdom
| | | | - Nasir Khan
- Chelsea & Westminster NHSFT, London, United Kingdom
| | - Glenn D. Flux
- Joint Department of Physics, Royal Marsden NHSFT, Sutton, United Kingdom,The Institute of Cancer Research, London, United Kingdom
| |
Collapse
|
6
|
Nodari G, Popoff R, Riedinger JM, Lopez O, Pellegrinelli J, Dygai-Cochet I, Tabouret-Viaud C, Presles B, Chevallier O, Gehin S, Gallet M, Latournerie M, Manfredi S, Loffroy R, Vrigneaud JM, Cochet A. Impact of contouring methods on pre-treatment and post-treatment dosimetry for the prediction of tumor control and survival in HCC patients treated with selective internal radiation therapy. EJNMMI Res 2021; 11:24. [PMID: 33687596 PMCID: PMC7943673 DOI: 10.1186/s13550-021-00766-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 02/23/2021] [Indexed: 12/16/2022] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the impact of the contouring methods on dose metrics and their predictive value on tumor control and survival, in both situations of pre-treatment and post-treatment dosimetry, for patients with advanced HCC treated with SIRT. METHODS Forty-eight patients who underwent SIRT between 2012 and 2020 were retrospectively included in this study. Target volumes were delineated using two methods: MRI-based contours manually drawn by a radiologist and then registered on SPECT/CT and PET/CT via deformable registration (Pre-CMRI and Post-CMRI), 99mTc-MAA-SPECT and 90Y-microspheres-PET 10% threshold contouring (Pre-CSPECT and Post-CPET). The mean absorbed dose (Dm) and the minimal absorbed dose delivered to 70% of the tumor volume (D70) were evaluated with both contouring methods; the tumor-to-normal liver uptake ratio (TNR) was evaluated with MRI-based contours only. Tumor response was assessed using the mRECIST criteria on the follow-up MRIs. RESULTS No significant differences were found for Dm and TNR between pre- and post-treatment. TNR evaluated with radiologic contours (Pre-CMRI and Post-CMRI) were predictive of tumor control at 6 months on pre- and post-treatment dosimetry (OR 5.9 and 7.1, respectively; p = 0.02 and 0.01). All dose metrics determined with both methods were predictive of overall survival (OS) on pre-treatment dosimetry, but only Dm with MRI-based contours was predictive of OS on post-treatment images with a median of 23 months for patients with a supramedian Dm versus 14 months for the others (p = 0.04). CONCLUSION In advanced HCC treated with SIRT, Dm and TNR determined with radiologic contours were predictive of tumor control and OS. This study shows that a rigorous clinical workflow (radiologic contours + registration on scintigraphic images) is feasible and should be prospectively considered for improving therapeutic strategy.
Collapse
Affiliation(s)
- Guillaume Nodari
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.
| | - Romain Popoff
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Jean Marc Riedinger
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | - Olivier Lopez
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Julie Pellegrinelli
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Inna Dygai-Cochet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | | | - Benoit Presles
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Olivier Chevallier
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France.,Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Sophie Gehin
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Matthieu Gallet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | | | - Sylvain Manfredi
- Department of Gastroenterology, University Hospital Dijon, Dijon, France
| | - Romaric Loffroy
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France.,Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Jean Marc Vrigneaud
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Alexandre Cochet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| |
Collapse
|
7
|
Dewaraja YK, Devasia T, Kaza RK, Mikell JK, Owen D, Roberson PL, Schipper MJ. Prediction of Tumor Control in 90Y Radioembolization by Logit Models with PET/CT-Based Dose Metrics. J Nucl Med 2019; 61:104-111. [PMID: 31147404 DOI: 10.2967/jnumed.119.226472] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 05/23/2019] [Indexed: 12/17/2022] Open
Abstract
The aim of this work was to develop models for tumor control probability (TCP) in radioembolization with 90Y PET/CT-derived radiobiologic dose metrics. Methods: Patients with primary liver cancer or liver metastases who underwent radioembolization with glass microspheres were imaged with 90Y PET/CT for voxel-level dosimetry to determine lesion absorbed dose (AD) metrics, biological effective dose (BED) metrics, equivalent uniform dose, and equivalent uniform BED for 28 treatments (89 lesions). The lesion dose-shrinkage correlation was assessed on the basis of RECIST and, when available, modified RECIST (mRECIST) at first follow-up. For a subset with mRECIST, logit regression TCP models were fit via maximum likelihood to relate lesion-level binary response to the dose metrics. As an exploratory analysis, the nontumoral liver dose-toxicity relationship was also evaluated. Results: Lesion dose-shrinkage analysis showed that there were no significant differences between model parameters for primary and metastatic subgroups and that correlation coefficients were superior with mRECIST. Therefore, subsequent TCP analysis was performed for the combined group using mRECIST only. The overall lesion-level mRECIST response rate was 57%. The AD and BED metrics yielding 50% TCP were 292 and 441 Gy, respectively. All dose metrics considered for TCP modeling, including mean AD, were significantly associated with the probability of response, with high areas under the curve (0.87-0.90, P < 0.0001) and high sensitivity (>0.75) and specificity (>0.83) calculated using a threshold corresponding to 50% TCP. Because nonuniform AD deposition by microspheres cannot be determined by PET at a microscopic scale, radiosensitivity values extracted here by fitting models to clinical response data were substantially lower than reported for in vitro cell cultures or for external-beam radiotherapy clinical studies. There was no correlation between nontumoral liver AD and toxicity measures. Conclusion: Despite the heterogeneous patient cohort, logistic regression TCP models showed a strong association between various dose metrics and the probability of response. The performance of mean AD was comparable to that of radiobiologic dose metrics that involve more complex calculations. These results demonstrate the importance of considering TCP in treatment planning for radioembolization.
Collapse
Affiliation(s)
- Yuni K Dewaraja
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Theresa Devasia
- Department of Biostatistics, University of Michigan, Ann Arbor, Michigan; and
| | - Ravi K Kaza
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Justin K Mikell
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Peter L Roberson
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Matthew J Schipper
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|