1
|
Larios F, Gonzalez MR, Ruiz-Arellanos K, Inchaustegui ML, Pretell-Mazzini J, de la Blanca JCG. Use of computer-assisted hexapod external fixators for complex foot and ankle reconstructions - An analysis of functional outcomes and complications. Foot Ankle Surg 2025; 31:153-159. [PMID: 39245585 DOI: 10.1016/j.fas.2024.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 08/27/2024] [Accepted: 08/28/2024] [Indexed: 09/10/2024]
Abstract
INTRODUCTION Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation. METHODS A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification. RESULTS A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %). CONCLUSIONS Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.
Collapse
Affiliation(s)
- Felipe Larios
- Facultad de Medicina Universidad Peruana Cayetano Heredia, Lima, Peru.
| | - Marcos R Gonzalez
- Division of Orthopaedic Oncology, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| | | | | | - Juan Pretell-Mazzini
- Miami Cancer Institute, Division of Orthopedic Oncology, Baptist Health System South Florida. Plantation, FL, USA.
| | - Juan Carlos G de la Blanca
- Limb Reconstruction Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Universitario Doce de Octubre, Madrid, Spain.
| |
Collapse
|
2
|
Flaxman TE, Cooke CM, Miguel OX, Sheikh A, McInnes M, Duigenan S, Singh SS. The Value of Using Patient-Specific 3D-Printed Anatomical Models in Surgical Planning for Patients With Complex Multifibroid Uteri. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2024; 46:102435. [PMID: 38458270 DOI: 10.1016/j.jogc.2024.102435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 02/15/2024] [Accepted: 02/16/2024] [Indexed: 03/10/2024]
Abstract
OBJECTIVES To compare surgeon responses regarding their surgical plan before and after receiving a patient-specific three-dimensional (3D)-printed model of a patient's multifibroid uterus created from their magnetic resonance imaging. METHODS 3D-printed models were derived from standard-of-care pelvic magnetic resonance images of patients scheduled for surgical intervention for multifibroid uterus. Relevant anatomical structures were printed using a combination of transparent and opaque resin types. 3D models were used for 7 surgical cases (5 myomectomies, 2 hysterectomies). A staff surgeon and 1 or 2 surgical fellow(s) were present for each case. Surgeons completed a questionnaire before and after receiving the model documenting surgical approach, perceived difficulty, and confidence in surgical plan. A postoperative questionnaire was used to assess surgeon experience using 3D models. RESULTS Two staff surgeons and 3 clinical fellows participated in this study. A total of 15 surgeon responses were collected across the 7 cases. After viewing the models, an increase in perceived surgical difficulty and confidence in surgical plan was reported in 12/15 and 7/15 responses, respectively. Anticipated surgical time had a mean ± SD absolute change of 44.0 ± 47.9 minutes and anticipated blood loss had an absolute change of 100 ± 103.5 cc. 2 of 15 responses report a change in pre-surgical approach. Intra-operative model reference was reported to change the dissection route in 8/15 surgeon responses. On average, surgeons rated their experience using 3D models 8.6/10 for pre-surgical planning and 8.1/10 for intra-operative reference. CONCLUSIONS Patient-specific 3D anatomical models may be a useful tool to increase a surgeon's understanding of complex gynaecologic anatomy and to improve their surgical plan. Future work is needed to evaluate the impact of 3D models on surgical outcomes in gynaecology.
Collapse
Affiliation(s)
- Teresa E Flaxman
- Ottawa Hospital Research Institute, Department of Clinical Epidemiology, Ottawa, ON; University of Ottawa, Faculty of Medicine, Department of Radiology, Radiation Oncology and Medical Physics, Ottawa, ON
| | - Carly M Cooke
- University of Ottawa, Faculty of Medicine, Department of Obstetrics and Gynecology, Ottawa, ON
| | - Olivier X Miguel
- Ottawa Hospital Research Institute, Department of Clinical Epidemiology, Ottawa, ON
| | - Adnan Sheikh
- University of British Columbia, Faculty of Medicine, Department of Radiology, Vancouver, BC
| | - Matthew McInnes
- Ottawa Hospital Research Institute, Department of Clinical Epidemiology, Ottawa, ON; University of Ottawa, Faculty of Medicine, Department of Radiology, Radiation Oncology and Medical Physics, Ottawa, ON; The Ottawa Hospital, Department of Medical Imaging, Ottawa, ON
| | - Shauna Duigenan
- University of Ottawa, Faculty of Medicine, Department of Radiology, Radiation Oncology and Medical Physics, Ottawa, ON; The Ottawa Hospital, Department of Medical Imaging, Ottawa, ON
| | - Sukhbir Sony Singh
- Ottawa Hospital Research Institute, Department of Clinical Epidemiology, Ottawa, ON; University of Ottawa, Faculty of Medicine, Department of Obstetrics and Gynecology, Ottawa, ON; The Ottawa Hospital, Department of Obstetrics, Gynecology and Newborn Care, Ottawa, ON.
| |
Collapse
|
3
|
Lucas SL, Gallagher BP, Mullinix KP, Brumback RJ, Cunningham BW. 3D-Printed Model in Preoperative Planning of Sciatic Nerve Decompression Because of Heterotopic Ossification: A Case Report. JBJS Case Connect 2024; 14:01709767-202403000-00033. [PMID: 38394316 DOI: 10.2106/jbjs.cc.23.00483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
CASE A 31-year-old patient presented with an encapsulated sciatic nerve secondary to extensive hip heterotopic ossification (HO), which prevented visualization of a safe osteotomy site to avoid nerve damage. The 3D-printed model demonstrated an easily identifiable osseous reference point along the inferior aspect of the heterotopic mass, allowing for a vertical osteotomy to be safely performed. CONCLUSION HO is associated with loss of normal anatomic topography. The current case report illustrates the use of a 3D-printed model to identify pertinent anatomic landmarks required for safe decompression of an encapsulated sciatic nerve within the anatomic region of the hip.
Collapse
Affiliation(s)
- Sarah L Lucas
- Georgetown University School of Medicine, Washington, District of Columbia
- Department of Orthopaedic Surgery, Musculoskeletal Research Center, MedStar Union Memorial Hospital, Baltimore, Maryland
| | - Brian P Gallagher
- Department of Orthopaedic Surgery, Musculoskeletal Research Center, MedStar Union Memorial Hospital, Baltimore, Maryland
| | - Kenneth P Mullinix
- Department of Orthopaedic Surgery, Musculoskeletal Research Center, MedStar Union Memorial Hospital, Baltimore, Maryland
| | - Robert J Brumback
- Department of Orthopaedic Surgery, Musculoskeletal Research Center, MedStar Union Memorial Hospital, Baltimore, Maryland
| | - Bryan W Cunningham
- Department of Orthopaedic Surgery, Musculoskeletal Research Center, MedStar Union Memorial Hospital, Baltimore, Maryland
| |
Collapse
|
4
|
Betancourt MC, Araújo C, Marín S, Buriticá W. The Quantitative Impact of Using 3D Printed Anatomical Models for Surgical Planning Optimization: Literature Review. 3D PRINTING AND ADDITIVE MANUFACTURING 2023; 10:1130-1139. [PMID: 37886412 PMCID: PMC10599434 DOI: 10.1089/3dp.2021.0188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2023]
Abstract
3D printing has entered the medical field as a visualization tool that allows the manufacture of three-dimensional (3D) models that physically represent the anatomy of a patient in need of analysis to improve surgical results. This article analyzes the literature around reported study cases that make use of anatomical models for their surgical processes' planning, focusing on obtaining the quantitative results of each one of them. A search of case studies was carried out in the main medical databases such as PubMed, ScienceDirect, SpringerLink, among others; to obtain the most relevant results of the 56 selected articles, the information of each study was analyzed and categorized. These articles presented figures and data about the benefits that are considered more representative to measure the positive impact of this technology. These benefits are summarized in variables such as the decrease in surgical time, greater accuracy in the diagnosis of pathology, blood loss reduction, and decreasing operating room costs; owed to an improvement in the surgery planning. It was found that in all the cases analyzed there was an improvement in the surgical results related to these variables, which were summarized in macro figures that combine this improvement quantitatively. In the analyzed studies, it was evident that there is great potential in the use of 3D printing for presurgical planning, being as the results of these analyzed interventions were better when using this technology. In addition, it was found that the results obtained initially, before applying the inclusion and exclusion criteria, were mostly of a qualitative nature; expressing the perception of researchers regarding the positive use of this tool in the field and evidencing an opportunity for this research to focus on concrete and technical information to show in numerical terms the effectiveness of this tool, to demonstrate the cost-benefit that it has for the field.
Collapse
|
5
|
Masada KM, Cristino DM, Dear KA, Hast MW, Mehta S. 3-D Printed Fracture Models Improve Resident Performance and Clinical Outcomes in Operative Fracture Management. JOURNAL OF SURGICAL EDUCATION 2023; 80:1020-1027. [PMID: 37198080 DOI: 10.1016/j.jsurg.2023.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 12/30/2022] [Accepted: 04/09/2023] [Indexed: 05/19/2023]
Abstract
OBJECTIVE To determine if preoperative examination of patient additive manufactured (AM) fracture models can be used to improve resident operative competency and patient outcomes. DESIGN Prospective cohort study. Seventeen matched pairs of fracture fixation surgeries (for a total of 34 surgeries) were performed. Residents first performed a set of baseline surgeries (n = 17) without AM fracture models. The residents then performed a second set of surgeries randomly assigned to include an AM model (n = 11) or to omit it (n = 6). Following each surgery, the attending surgeon evaluated the resident using an Ottawa Surgical Competency Operating Room Evaluation (O-Score). The authors also recorded clinical outcomes including operative time, blood loss, fluoroscopy duration, and patient reported outcome measurement information system (PROMIS) scores of pain and function at 6 months. SETTING Single-center academic level one trauma center. PARTICIPANTS Twelve orthopaedic residents, between postgraduate year (PGY) 2 and 5, participated in this study. RESULTS Residents significantly improved their O-Scores between the first and second surgery when they trained with AM models for the second surgery (p = 0.004, 2.43 ± 0.79 versus 3.73 ± 0.64). Similar improvements were not observed in the control group (p = 0.916, 2.69 ± 0.69 versus 2.77 ± 0.36). AM model training also significantly improved clinical outcomes, including surgery time (p = 0.006), fluoroscopy exposure time (p = 0.002), and patient reported functional outcomes (p = 0.0006). CONCLUSIONS Conclusions: Training with AM fracture models improves the performance of orthopaedic surgery residents during fracture surgery.
Collapse
Affiliation(s)
- Kendall M Masada
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania.
| | - Danielle M Cristino
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Kayley A Dear
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Michael W Hast
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Samir Mehta
- McKay Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
6
|
Yahia S, Khalil IA, Ghoniem MG, El-Sherbiny IM. 3D-bioimplants mimicking the structure and function of spine units for the treatment of spinal tuberculosis. RSC Adv 2023; 13:17340-17353. [PMID: 37304785 PMCID: PMC10251188 DOI: 10.1039/d3ra02351f] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 06/02/2023] [Indexed: 06/13/2023] Open
Abstract
Approximately 1-2% of the reported tuberculosis (TB) cases have skeletal system problems, particularly spinal TB. The complications of spinal TB involve the destruction of vertebral body (VB) and intervertebral disc (IVD) which consequently leads to kyphosis. This work aimed at utilizing different technologies to develop, for the first time, a functional spine unit (FSU) replacement to mimic the structure and function of the VB and IVD along with a good ability to treat spinal TB. 3D-printed scaffolds with different porous patterns (hexagonal or grid) were fabricated from biocompatible acrylonitrile butadiene styrene, and polylactic acid to replace damaged VB and IVD, respectively. The VB scaffold is filled with gelatine-based semi-IPN hydrogel containing mesoporous silica nanoparticles loaded with two antibiotics, rifampicin and levofloxacin, to act against TB. The IVD scaffold incorporates a gelatin hydrogel loaded with regenerative platelet-rich plasma and anti-inflammatory simvastatin-loaded mixed nanomicelles. The obtained results confirmed the superior mechanical strength of both 3D-printed scaffolds and loaded hydrogels as compared to normal bone and IVD with high in vitro (cell proliferation, anti-inflammation and anti-TB), and in vivo biocompatibility profiles. Moreover, the custom-designed replacements have achieved the expected prolonged release of antibiotics up to 60 days. Given the promising study findings, the utilization of the developed drug-eluting scaffold system can be extrapolated to treat not only spinal TB but also to resolve diverse backbone/spine problems that need a critical surgical process including degenerative IVD and its consequences like atherosclerosis, sliding or spondylolisthesis and severe traumatic bone fracture.
Collapse
Affiliation(s)
- Sarah Yahia
- Nanomedicine Research Labs, Center for Materials Sciences, Zewail City of Science and Technology 6th of October City 12578 Giza Egypt
| | - Islam A Khalil
- Department of Pharmaceutics, College of Pharmacy and Drug Manufacturing, Misr University of Science and Technology (MUST) 6th of October Giza 12582 Egypt
| | - Monira G Ghoniem
- Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU) Riyadh 11623 Saudi Arabia
| | - Ibrahim M El-Sherbiny
- Nanomedicine Research Labs, Center for Materials Sciences, Zewail City of Science and Technology 6th of October City 12578 Giza Egypt
| |
Collapse
|
7
|
Zheng H, Wang L, Jiang W, Qin R, Zhang Z, Jia Z, Zhang J, Liu Y, Gao X. Application of 3D printed patient-specific instruments in the treatment of large tibial bone defects by the Ilizarov technique of distraction osteogenesis. Front Surg 2023; 9:985110. [PMID: 36684263 PMCID: PMC9852528 DOI: 10.3389/fsurg.2022.985110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 10/31/2022] [Indexed: 01/09/2023] Open
Abstract
Background The Ilizarov technique of distraction osteogenesis is an effective treatment for tibia defect. However, repeated attempts to reduce due to the complexity of the bone defect during the operation will increase the operation time and iatrogenic injury, and excessive radiation exposure. Three-dimensional (3D)-printed patient-specific instrument (PSI) for preoperative 3D planning and intraoperative navigation have the advantages of accuracy and visualization. The purpose of this study is to investigate whether 3D-printed PSI is helpful to correct tibial bone defects accurately and effectively. Method From May 2019 to September 2022, 19 patients with tibial bone defects were treated, including 9 males and 10 females, aged 37 to 64 years. There were 4 cases in proximal tibia, 9 in midshaft tibia and 6 in distal tibia. All were treated with Ilizarov technique of distraction osteogenesis. 3D-printed PSI was used in 9 cases, while traditional surgery was used in 10 cases. All patients underwent computed tomography before surgery. Computer software was used to analyze the measurement results, design and print PSI. During the operation, PSI was used to assist in reduction of tibia. Operation times were recorded in all cases, the number of fluoroscopy during the operation, and the varus/valgus, anteversion/reversion angle after the operation were measured. All measurement data were expressed by means ± SD, and Student's t test was used to examine differences between groups. The chi square test or Fisher's precise test was used to compare the counting data of the two groups. Result All PSI matched well with the corresponding tibia bone defect, and were consistent with the preoperative plan and intraoperative operation. The affected limb had a good reduction effect. The operation time from the beginning of PSI installation to the completion of Ilizarov ring fixator installation was 31.33 ± 3.20 min, while that in the traditional operation group was 64.10 ± 6.14 min (p < 0.001). The times of fluoroscopy in the PSI group during operation was 10.11 ± 1.83, and that in the traditional operation group was 27.60 ± 5.82. The reduction effect of tibia in PSI group was better than that in traditional operation group, with the average angle of PSI group is 1.21 ± 0.24°, and that of traditional operation group is 2.36 ± 0.33° (p < 0.001). Conclusion The PSI simplifies procedures, reduces the difficulty of the operation, improves the accuracy of the operation, and provides a good initial position when used in distraction osteogenesis to treat the tibial defects.
Collapse
Affiliation(s)
- Hao Zheng
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Lili Wang
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Wenbo Jiang
- Clinical and Translational Research Center for 3D Printing Technology, Shanghai Ninth People’ s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ruiqing Qin
- Clinical and Translational Research Center for 3D Printing Technology, Shanghai Ninth People’ s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zhiyu Zhang
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Zhuqing Jia
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Jian Zhang
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China
| | - Yong Liu
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China,Correspondence: Xuejian Gao Yong Liu
| | - Xuejian Gao
- Department of Trauma Surgery, Affiliated Hospital of Weifang Medical University, Weifang, China,School of Clinical Medicine, Weifang Medical University, Weifang, China,Correspondence: Xuejian Gao Yong Liu
| |
Collapse
|
8
|
Meyer-Szary J, Luis MS, Mikulski S, Patel A, Schulz F, Tretiakow D, Fercho J, Jaguszewska K, Frankiewicz M, Pawłowska E, Targoński R, Szarpak Ł, Dądela K, Sabiniewicz R, Kwiatkowska J. The Role of 3D Printing in Planning Complex Medical Procedures and Training of Medical Professionals-Cross-Sectional Multispecialty Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:3331. [PMID: 35329016 PMCID: PMC8953417 DOI: 10.3390/ijerph19063331] [Citation(s) in RCA: 65] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/18/2022] [Accepted: 03/05/2022] [Indexed: 12/19/2022]
Abstract
Medicine is a rapidly-evolving discipline, with progress picking up pace with each passing decade. This constant evolution results in the introduction of new tools and methods, which in turn occasionally leads to paradigm shifts across the affected medical fields. The following review attempts to showcase how 3D printing has begun to reshape and improve processes across various medical specialties and where it has the potential to make a significant impact. The current state-of-the-art, as well as real-life clinical applications of 3D printing, are reflected in the perspectives of specialists practicing in the selected disciplines, with a focus on pre-procedural planning, simulation (rehearsal) of non-routine procedures, and on medical education and training. A review of the latest multidisciplinary literature on the subject offers a general summary of the advances enabled by 3D printing. Numerous advantages and applications were found, such as gaining better insight into patient-specific anatomy, better pre-operative planning, mock simulated surgeries, simulation-based training and education, development of surgical guides and other tools, patient-specific implants, bioprinted organs or structures, and counseling of patients. It was evident that pre-procedural planning and rehearsing of unusual or difficult procedures and training of medical professionals in these procedures are extremely useful and transformative.
Collapse
Affiliation(s)
- Jarosław Meyer-Szary
- Department of Pediatric Cardiology and Congenital Heart Defects, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Marlon Souza Luis
- Department of Pediatric Cardiology and Congenital Heart Defects, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
- First Doctoral School, Medical University of Gdańsk, 80-211 Gdańsk, Poland
| | - Szymon Mikulski
- Department of Head and Neck Surgery, Singapore General Hospital, Singapore 169608, Singapore
| | - Agastya Patel
- First Doctoral School, Medical University of Gdańsk, 80-211 Gdańsk, Poland
- Department of General, Endocrine and Transplant Surgery, Faculty of Medicine, Medical University of Gdańsk, 80-214 Gdańsk, Poland
| | - Finn Schulz
- University Clinical Centre in Gdańsk, 80-952 Gdańsk, Poland
| | - Dmitry Tretiakow
- Department of Otolaryngology, Faculty of Medicine, Medical University of Gdańsk, 80-214 Gdańsk, Poland
| | - Justyna Fercho
- Neurosurgery Department, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Kinga Jaguszewska
- Department of Gynecology, Obstetrics and Neonatology, Division of Gynecology and Obstetrics, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Mikołaj Frankiewicz
- Department of Urology, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Ewa Pawłowska
- Department of Oncology and Radiotherapy, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Radosław Targoński
- 1st Department of Cardiology, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Łukasz Szarpak
- Institute of Outcomes Research, Maria Sklodowska-Curie Medical Academy, 03-411 Warsaw, Poland
- Research Unit, Maria Sklodowska-Curie Bialystok Oncology Center, 15-027 Bialystok, Poland
- Henry JN Taub Department of Emergency Medicine, Baylor College of Medicine, Houston, TX 77030, USA
| | - Katarzyna Dądela
- Department of Pediatric Cardiology, University Children's Hospital, Faculty of Medicine, Jagiellonian University Medical College, 30-663 Krakow, Poland
| | - Robert Sabiniewicz
- Department of Pediatric Cardiology and Congenital Heart Defects, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| | - Joanna Kwiatkowska
- Department of Pediatric Cardiology and Congenital Heart Defects, Faculty of Medicine, Medical University of Gdańsk, 80-210 Gdańsk, Poland
| |
Collapse
|
9
|
Agarwal R, Malhotra S, Gupta V, Jain V. The application of Three-dimensional printing on foot fractures and deformities: A mini-review. ANNALS OF 3D PRINTED MEDICINE 2022. [DOI: 10.1016/j.stlm.2022.100046] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
10
|
An overview of 3D printing and the orthopaedic application of patient-specific models in malunion surgery. Injury 2022; 53:977-983. [PMID: 34838259 DOI: 10.1016/j.injury.2021.11.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 10/12/2021] [Accepted: 11/09/2021] [Indexed: 02/02/2023]
Abstract
As the emerging technology of three-dimensional (3D) printing impacts several facets of medicine, innovative techniques and applications are increasingly being incorporated into clinical workflows. Specifically, 3D printing technology has allowed for the individualization of patient care through the creation of printed surgical guides, patient-specific anatomical models, and simulation practice models. In this paper, we review the broad applications of 3D printing in orthopaedic surgery. The purpose of this paper is to help orthopaedic trauma surgeons understand 3D printing's emerging influence on the delivery of care as well as how to directly apply this technology to their practice. We aim to illustrate these principles through a specific example of a patient who presented for malunion surgery. A 3D printed model of a very complex traumatic scapula malunion was used to not only pre-surgically plan the reconstruction, but to also facilitate provider and patient education. This paper highlights the benefits of 3D printing and how trauma surgeons are uniquely positioned to apply this technology to improve patient care.
Collapse
|
11
|
Laubscher M, Nieuwoudt L, Marais L. Effect of frame and fixation factors on the incidence of pin site infections in circular external fixation of the tibia: A systematic review of comparative studies. JOURNAL OF LIMB LENGTHENING & RECONSTRUCTION 2022. [DOI: 10.4103/jllr.jllr_1_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
|
12
|
Chen Y, Niu Z, Jiang W, Tao R, Lei Y, Guo L, Zhang K, Xia W, Song B, Huang L, Zhang Q, Han Y. 3D-printed models improve surgical planning for correction of severe postburn ankle contracture with an external fixator. J Zhejiang Univ Sci B 2021; 22:866-875. [PMID: 34636189 DOI: 10.1631/jzus.b2000576] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Gradual distraction with an external fixator is a widely used treatment for severe postburn ankle contracture (SPAC). However, application of external fixators is complex, and conventional two-dimensional (2D) imaging-based surgical planning is not particularly helpful due to a lack of spatial geometry. The purpose of this study was to evaluate the surgical planning process for this procedure with patient-specific three-dimension-printed models (3DPMs). In this study, patients coming from two centers were divided into two cohorts (3DPM group vs. control group) depending on whether a 3DPM was used for preoperative surgical planning. Operation duration, improvement in metatarsal-tibial angle (MTA), range of motion (ROM), the American Orthopedic Foot and Ankle Society (AOFAS) scores, complications, and patient-reported satisfaction were compared between two groups. The 3DPM group had significantly shorter operation duration than the control group ((2.0±0.3) h vs. (3.2±0.3) h, P<0.01). MTA, ROM, and AOFAS scores between the two groups showed no significant differences pre-operation, after the removal of the external fixator, or at follow-up. Plantigrade feet were achieved and gait was substantially improved in all patients at the final follow-up. Pin-tract infections occurred in two patients (one in each group) during distraction and were treated with wound care and oral antibiotics. Patients in the 3DPM group reported higher satisfaction than those in the control group, owing to better patient-surgeon communication. Surgical planning using patient-specific 3DPMs significantly reduced operation duration and increased patient satisfaction, while providing similar improvements in ankle movement and function compared to traditional surgical planning for the correction of SPAC with external fixators.
Collapse
Affiliation(s)
- Youbai Chen
- Department of Plastic and Reconstructive Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Zehao Niu
- Graduate School, Medical School of Chinese PLA, Beijing 100853, China
| | - Weiqian Jiang
- Department of Plastic and Reconstructive Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Ran Tao
- Department of Plastic and Reconstructive Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Yonghong Lei
- Department of Plastic and Reconstructive Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Lingli Guo
- Department of Plastic and Reconstructive Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Kexue Zhang
- Department of Pediatric Orthopedics, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Wensen Xia
- Department of Plastic Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710038, China
| | - Baoqiang Song
- Department of Plastic Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710038, China
| | - Luyu Huang
- Department of Orthopedics, Xijing Hospital, Air Force Medical University, Xi'an 710038, China
| | - Qixu Zhang
- Department of Plastic Surgery, the University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | - Yan Han
- Department of Plastic and Reconstructive Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing 100853, China.
| |
Collapse
|
13
|
Zhang Z, Yang J, Zou H, Wang W, Wu X, Lin X. Mathematical Analysis of Application of a Three-Dimensional Printing Fixator in the Fracture of Multiple Ribs. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE : ECAM 2021; 2021:5626228. [PMID: 34630610 PMCID: PMC8500754 DOI: 10.1155/2021/5626228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 09/25/2021] [Indexed: 11/23/2022]
Abstract
Data were obtained from 66 clinical patients. The patients were divided into a non-3D printing group (control group) and a 3D printing group (intervention group) in a 1 : 1 ratio, with 33 patients in each group. The information including gender, age, incision length, number of surgical roots, bleeding volume, operation time, and intraoperative blood transfusion was collected for SPSS analysis. The results showed the following: (1) The paired t-test was used to test the difference of experimental data. There was a significant difference of 0.01 between the incision length/surgical root number in the intervention group and the incision length/surgical root number in the control group. The incision length/surgical root number in the intervention group was significantly lower than that in the control group. (2) Surgical time, intraoperative blood transfusion, age, and incision length/surgical root number in the intervention group had a significant positive impact on the amount of bleeding. Gender did not affect the amount of bleeding. (3) A total of 1 item of operation time in the intervention group had a significant positive impact on intraoperative blood transfusion. (4) The incision length/number of surgical roots in the intervention group had a noteworthy negative impact on blood transfusion during the operation.
Collapse
Affiliation(s)
- Zhigong Zhang
- Department of Cardiothoracic Surgery, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha 410005, China
| | - Jinsong Yang
- Department of Cardiothoracic Surgery, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha 410005, China
| | - Haoyu Zou
- Department of Cardiothoracic Surgery, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha 410005, China
| | - Wen Wang
- Department of Cardiothoracic Surgery, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha 410005, China
| | - Xiangyi Wu
- Department of Cardiothoracic Surgery, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha 410005, China
| | - Xiaojuan Lin
- Department of Paediatrics, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha 410005, China
| |
Collapse
|
14
|
Flaxman TE, Cooke CM, Miguel OX, Sheikh AM, Singh SS. A review and guide to creating patient specific 3D printed anatomical models from MRI for benign gynecologic surgery. 3D Print Med 2021; 7:17. [PMID: 34224043 PMCID: PMC8256564 DOI: 10.1186/s41205-021-00107-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 06/10/2021] [Indexed: 11/10/2022] Open
Abstract
Background Patient specific three-dimensional (3D) models can be derived from two-dimensional medical images, such as magnetic resonance (MR) images. 3D models have been shown to improve anatomical comprehension by providing more accurate assessments of anatomical volumes and better perspectives of structural orientations relative to adjacent structures. The clinical benefit of using patient specific 3D printed models have been highlighted in the fields of orthopaedics, cardiothoracics, and neurosurgery for the purpose of pre-surgical planning. However, reports on the clinical use of 3D printed models in the field of gynecology are limited. Main text This article aims to provide a brief overview of the principles of 3D printing and the steps required to derive patient-specific, anatomically accurate 3D printed models of gynecologic anatomy from MR images. Examples of 3D printed models for uterine fibroids and endometriosis are presented as well as a discussion on the barriers to clinical uptake and the future directions for 3D printing in the field of gynecological surgery. Conclusion Successful gynecologic surgery requires a thorough understanding of the patient’s anatomy and burden of disease. Future use of patient specific 3D printed models is encouraged so the clinical benefit can be better understood and evidence to support their use in standard of care can be provided.
Collapse
Affiliation(s)
- Teresa E Flaxman
- Department of Clinical Epidemiology, Ottawa Hospital Research Institute, 1967 Riverside Dr, 7th Floor, Ottawa, ON, K1H7W9, Canada. .,Department of Obstetrics and Gynecology, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
| | - Carly M Cooke
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada
| | - Olivier X Miguel
- Department of Clinical Epidemiology, Ottawa Hospital Research Institute, 1967 Riverside Dr, 7th Floor, Ottawa, ON, K1H7W9, Canada.,Department of Medical Imaging, The Ottawa Hospital, Ottawa, ON, Canada
| | - Adnan M Sheikh
- Department of Clinical Epidemiology, Ottawa Hospital Research Institute, 1967 Riverside Dr, 7th Floor, Ottawa, ON, K1H7W9, Canada.,Department of Medical Imaging, The Ottawa Hospital, Ottawa, ON, Canada.,Department of Radiology, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada
| | - Sukhbir S Singh
- Department of Clinical Epidemiology, Ottawa Hospital Research Institute, 1967 Riverside Dr, 7th Floor, Ottawa, ON, K1H7W9, Canada.,Department of Obstetrics and Gynecology, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.,Department of Obstetrics, Gynecology and Newborn Care, The Ottawa Hospital, Ottawa, ON, Canada
| |
Collapse
|
15
|
Overview of In-Hospital 3D Printing and Practical Applications in Hand Surgery. BIOMED RESEARCH INTERNATIONAL 2021; 2021:4650245. [PMID: 33855068 PMCID: PMC8019389 DOI: 10.1155/2021/4650245] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 01/03/2021] [Accepted: 03/22/2021] [Indexed: 12/12/2022]
Abstract
Three-dimensional (3D) printing is spreading in hand surgery. There is an increasing number of practical applications like the training of junior hand surgeons, patient education, preoperative planning, and 3D printing of customized casts, customized surgical guides, implants, and prostheses. Some high-quality studies highlight the value for surgeons, but there is still a lack of high-level evidence for improved clinical endpoints and hence actual impact on the patient's outcome. This article provides an overview over the latest applications of 3D printing in hand surgery and practical experience of implementing them into daily clinical routine.
Collapse
|
16
|
Liu PR, Lu L, Zhang JY, Huo TT, Liu SX, Ye ZW. Application of Artificial Intelligence in Medicine: An Overview. Curr Med Sci 2021; 41:1105-1115. [PMID: 34874486 PMCID: PMC8648557 DOI: 10.1007/s11596-021-2474-3] [Citation(s) in RCA: 87] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 12/01/2020] [Indexed: 02/06/2023]
Abstract
Artificial intelligence (AI) is a new technical discipline that uses computer technology to research and develop the theory, method, technique, and application system for the simulation, extension, and expansion of human intelligence. With the assistance of new AI technology, the traditional medical environment has changed a lot. For example, a patient's diagnosis based on radiological, pathological, endoscopic, ultrasonographic, and biochemical examinations has been effectively promoted with a higher accuracy and a lower human workload. The medical treatments during the perioperative period, including the preoperative preparation, surgical period, and postoperative recovery period, have been significantly enhanced with better surgical effects. In addition, AI technology has also played a crucial role in medical drug production, medical management, and medical education, taking them into a new direction. The purpose of this review is to introduce the application of AI in medicine and to provide an outlook of future trends.
Collapse
Affiliation(s)
- Peng-ran Liu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Lin Lu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Jia-yao Zhang
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Tong-tong Huo
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Song-xiang Liu
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Zhe-wei Ye
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| |
Collapse
|
17
|
Branson TM, Shapiro L, Venter RG. Observation of Patients' 3D Printed Anatomical Features and 3D Visualisation Technologies Improve Spatial Awareness for Surgical Planning and in-Theatre Performance. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1334:23-37. [PMID: 34476743 DOI: 10.1007/978-3-030-76951-2_2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Improved spatial awareness is vital in anatomy education as well as in many areas of medical practice. Many healthcare professionals struggle with the extrapolation of 2D data to its locus within the 3D volume of the anatomy. In this chapter, we outline the use of touch as an important sensory modality in the observation of 3D forms, including anatomical parts, with the specific neuroscientific underpinnings in this regard being described. We explore how improved spatial awareness is directly linked to improved spatial skill. The reader is offered two practical exercises that lead to improved spatial awareness for application in exploring external 3D anatomy volume as well as internal 3D anatomy volume. These exercises are derived from the Haptico-visual observation and drawing (HVOD) method. The resulting cognitive improvement in spatial awareness that these exercises engender can be of benefit to students in their study of anatomy and for application by healthcare professionals in many aspects of their medical practice. The use of autostereoscopic visualisation technology (AS3D) to view the anatomy from DICOM data, in combination with the haptic exploration of a 3D print (3Dp) of the same stereoscopic on-screen image, is recommended as a practice for improved understanding of any anatomical part or feature. We describe a surgical innovation that relies on the haptic perception of patients' 3D printed (3Dp) anatomical features from patient DICOM data, for improved surgical planning and in-theatre surgical performance. Throughout the chapter, underlying neuroscientific correlates to haptic and visual observation, memory, working memory, and cognitive load are provided.
Collapse
Affiliation(s)
- Toby M Branson
- Department of Health and Medical Sciences, Adelaide Medical School, The University of Adelaide, Adelaide, SA, Australia
| | - Leonard Shapiro
- Division of Clinical Anatomy and Biological Anthropology, Department of Human Biology, University of Cape Town, Cape Town, South Africa.
| | - Rudolph G Venter
- Faculty of Medicine and Health Science, Division of Orthopaedic Surgery, Stellenbosch University, Stellenbosch, South Africa
| |
Collapse
|
18
|
Jacquet C, Sharma A, Fabre M, Ehlinger M, Argenson JN, Parratte S, Ollivier M. Patient-specific high-tibial osteotomy's 'cutting-guides' decrease operating time and the number of fluoroscopic images taken after a Brief Learning Curve. Knee Surg Sports Traumatol Arthrosc 2020; 28:2854-2862. [PMID: 31352498 DOI: 10.1007/s00167-019-05637-6] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 07/16/2019] [Indexed: 11/30/2022]
Abstract
PURPOSE Patient-specific cutting guides (PSCGs) have been advocated to improve the accuracy of deformity correction in opening-wedge high-tibial osteotomies (HTO). It was hypothesized that PSCGs for HTO would have a short learning curve. Therefore, the goals of this study were to determine the surgeons learning curve for PSCGs used for opening-wedge HTO assessing: the operating time, surgeons comfort levels, number of fluoroscopic images, accuracy of post-operative limb alignment and functional outcomes. METHODS This prospective cohort study included 71 consecutive opening-wedge HTO with PSCGs performed by three different surgeons with different experiences. The operating time, the surgeon's anxiety levels evaluated using the Spielberger State-Trait Anxiety Inventory (STAI), the number of fluoroscopic images was systematically and prospectively collected. The accuracy of the postoperative alignment was defined by the difference between the preoperative targeted correction and the final post-operative correction both measured on standardized CT-scans using the same protocol (ΔHKA, ΔMPTA, ΔPPTA). Functional outcomes were evaluated at 1 year using the different sub-scores of the KOOS. Cumulative summation (CUSUM) analyses were used to assess learning curves. RESULTS The use of PSCGs in HTO surgery was associated with a learning curve of 10 cases to optimize operative time (mean operative time 26.3 min ± 8.8), 8 cases to lessen surgeon anxiety levels, and 9 cases to decrease the number of fluoroscopic images to an average of 4.3 ± 1.2. Cumulative PSCGs experience did not affect accuracy of post-operative limb alignment with a mean: ΔHKA = 1.0° ± 1.0°, ΔMPTA = 0.5° ± 0.6° and ΔPPTA = 0.4° ± 0.8°. No significant difference was observed between the three surgeons for these three parameters. There was no statistical correlation between the number of procedures performed and the patient's functional outcomes. CONCLUSION The use of PSCGs requires a short learning curve to optimize operating time, reduce the use of fluoroscopy and lessen surgeon's anxiety levels. Additionally, this learning phase does not affect the accuracy of the postoperative correction and the functional results at 1 year. LEVEL OF EVIDENCE II: prospective observational study.
Collapse
Affiliation(s)
- Christophe Jacquet
- Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France.,Department of Orthopedics and Traumatology, Institute for Locomotion, APHM, CNRS, ISM, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France
| | - Akash Sharma
- Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France.,Department of Orthopedics and Traumatology, Institute for Locomotion, APHM, CNRS, ISM, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France
| | - Maxime Fabre
- Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France.,Department of Orthopedics and Traumatology, Institute for Locomotion, APHM, CNRS, ISM, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France
| | - Matthieu Ehlinger
- Service de Chirurgie Orthopédique et de Traumatologie, CHU Hautepierre, Hôpital de Hautepierre, Hôpitaux Universitaires de Strasbourg, 1 Avenue Molière, 67098, Strasbourg Cedex, France
| | - Jean-Noël Argenson
- Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France
| | - Sebastien Parratte
- Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France.,Department of Orthopedics and Traumatology, Institute for Locomotion, APHM, CNRS, ISM, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France.,International Knee and Joint Centre, Abu Dhabi, UAE
| | - Matthieu Ollivier
- Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, St Marguerite Hospital, 270 Boulevard Sainte Marguerite, BP 29 13274, Marseille, France. .,Department of Orthopedics and Traumatology, Institute for Locomotion, APHM, CNRS, ISM, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France.
| |
Collapse
|
19
|
Configuration design and correction ability evaluation of a novel external fixator for foot and ankle deformity treated by U osteotomy. Med Biol Eng Comput 2020; 58:541-558. [DOI: 10.1007/s11517-019-02103-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2019] [Accepted: 12/17/2019] [Indexed: 10/25/2022]
|
20
|
Jiang M, Chen G, Coles‐Black J, Chuen J, Hardidge A. Three‐dimensional printing in orthopaedic preoperative planning improves intraoperative metrics: a systematic review. ANZ J Surg 2019; 90:243-250. [DOI: 10.1111/ans.15549] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 09/19/2019] [Accepted: 09/22/2019] [Indexed: 12/18/2022]
Affiliation(s)
- Michael Jiang
- 3DMedLab, Austin HealthThe University of Melbourne Melbourne Victoria Australia
- Department of Orthopaedic SurgeryAustin Health Melbourne Victoria Australia
| | - Gordon Chen
- 3DMedLab, Austin HealthThe University of Melbourne Melbourne Victoria Australia
| | - Jasamine Coles‐Black
- 3DMedLab, Austin HealthThe University of Melbourne Melbourne Victoria Australia
- Department of SurgeryThe University of Melbourne Melbourne Victoria Australia
- Department of Vascular SurgeryAustin Health Melbourne Victoria Australia
| | - Jason Chuen
- 3DMedLab, Austin HealthThe University of Melbourne Melbourne Victoria Australia
- Department of SurgeryThe University of Melbourne Melbourne Victoria Australia
- Department of Vascular SurgeryAustin Health Melbourne Victoria Australia
| | - Andrew Hardidge
- Department of Orthopaedic SurgeryAustin Health Melbourne Victoria Australia
- Department of SurgeryThe University of Melbourne Melbourne Victoria Australia
| |
Collapse
|
21
|
[3D printing in orthopedic and trauma surgery education and training : Possibilities and fields of application]. Unfallchirurg 2019; 122:444-451. [PMID: 31053925 DOI: 10.1007/s00113-019-0650-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
The 3D printing technology enables precise fracture models to be generated from volumetric digital imaging and communications in medicine (DICOM) computed tomography (CT) data. Apart from patient treatment, in the future this technology could potentially play a significant role in education and training in the field of orthopedic and trauma surgery. Preliminary results show that the understanding and classification of fractures can be improved when teaching medical students. The use of life-size and haptic models of real fractures for education is particularly interesting. Even experienced surgeons show an improved classification and treatment planning with the help of 3D printed models when compared to plain CT data. Especially for complex articular fractures, such as those of the acetabulum and tibial plateau, initial evidence shows patient benefits in terms of reduced surgery time and blood loss with the help of 3D models. The use of 3D printing on-site at the hospital is of particular interest in orthopedic and trauma surgery as it promises to provide products within a short time. The low investment and running costs and the increasing availability of convenient software solutions will spur increasing dissemination of this technology in the coming years.
Collapse
|
22
|
Dahl MT, Morrison SG, Georgiadis AG, Huser AJ. What's New in Limb Lengthening and Deformity Correction. J Bone Joint Surg Am 2019; 101:1435-1439. [PMID: 31436650 DOI: 10.2106/jbjs.19.00584] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Mark T Dahl
- Gillette Children's Specialty Healthcare, St. Paul, Minnesota
- University of Minnesota, Minneapolis, Minnesota
| | - Stewart G Morrison
- Gillette Children's Specialty Healthcare, St. Paul, Minnesota
- University of Minnesota, Minneapolis, Minnesota
| | - Andrew G Georgiadis
- Gillette Children's Specialty Healthcare, St. Paul, Minnesota
- University of Minnesota, Minneapolis, Minnesota
| | - Aaron J Huser
- Gillette Children's Specialty Healthcare, St. Paul, Minnesota
- University of Minnesota, Minneapolis, Minnesota
| |
Collapse
|