Özkaya M, Tunalı S, Köksal İ, Demir T. Mechanical comparison of standard interlocking, clawed, and expandable wedge locked nail fixations: An experimental and numerical study.
Injury 2023;
54:379-394. [PMID:
36509566 DOI:
10.1016/j.injury.2022.12.002]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 11/22/2022] [Accepted: 12/02/2022] [Indexed: 12/11/2022]
Abstract
INTRODUCTION
Intramedullary nailing has been used as a standard in the treatment of the long bone fractures with its clinical and mechanical advantages. However, using distal locking screws has been associated with longer operative times, higher radiation exposure rates, and complications like breakages of distal screw or nail at the screw hole level. Therefore, attempts to eliminate distal locking screws has been always present for intramedullary nail fixation. With a similar purpose, the present study has been carried out to compare mechanical behaviors of intramedullary nail fixations with different distal locking elements.
MATERIALS AND METHODS
In this study, mechanical behaviors of standard interlocking and clawed nail fixations were compared experimentally in the first part. Six fourth generation Sawbones femurs, which have a simulated subtrochanteric fracture, were divided equally and were fixed with standard interlocking and clawed nails. During axial compression tests, experimental strain measurements were taken from all fixations. After validation of numerical models with using experimental strains and stiffnesses, mechanical behaviors of standard interlocking, clawed, and wedge locked nail fixations were compared numerically under axial compression loads. In numerical comparison, the stress-strain distributions were evaluated.
RESULTS
Experimental results showed that although that there was no significant difference in stiffnesses, standard nail fixation bore two times higher loads than clawed nail fixations. Under loading, decrease in the distance between fracture surfaces was approximately seven times higher in the clawed nail fixation when compared to standard nail fixations. Numerical results showed that wedge locked nail fixation provided equivalent mechanical behavior to standard interlocking nail.
DISCUSSION
In experiments of clawed nail fixation, the high decrease in the distance between fracture surfaces was evidence of the slippage of nail in the medullary canal. For a safe fixation, claws should be deployed when they are completely in contact with the cortical bone, they should be stuck into the bone in a fair amount, and the deployment in the distal third of the femur should be avoided. According to experimentally validated numerical analyses, wedge locked nail fixation may be an alternative for standard interlocking nail fixation if experimental studies support the present results.
Collapse