1
|
Pokorney SD. Indications for Lead Extraction. Card Electrophysiol Clin 2024; 16:403-410. [PMID: 39461831 DOI: 10.1016/j.ccep.2024.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/29/2024]
Abstract
Cardiac implantable electronic devices (CIEDs) are being implanted at increasing rates. Patients with CIEDs require more lead management in contemporary clinical practice, given the increased survival of heart failure patients. There are multiple indications for extraction with the strongest class I indications being in patients with CIED infections. Extraction with complete hardware removal is underutilized and often delayed when it is utilized in patients with CIED infections, resulting in higher mortality. Patient and provider preferences are critical to decision-making when considering extraction. Lead extraction referral and management care pathways are needed in order to optimize care for our patients with CIEDs.
Collapse
Affiliation(s)
- Sean D Pokorney
- Division of Cardiology, Duke University Medical Center, Durham, NC 27710, USA; Department of Medicine, Duke Clinical Research Institute, Durham, NC 27710, USA.
| |
Collapse
|
2
|
Mousa Basha M, Al-Kassou B, Gestrich C, Weber M, Beiert T, Bakhtiary F, Nickenig G, Zimmer S, Shamekhi J. Microbial growth on temporary pacemaker leads post-TAVR: pathogen spectrum and clinical implications. Clin Res Cardiol 2024:10.1007/s00392-024-02543-x. [PMID: 39256220 DOI: 10.1007/s00392-024-02543-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Accepted: 08/30/2024] [Indexed: 09/12/2024]
Abstract
BACKGROUND AND OBJECTIVE Transcatheter aortic valve replacement (TAVR) is an established treatment option for patients with symptomatic severe aortic stenosis across all stages of surgical risk. Rapid pacing during the procedure and the risk for the occurrence of conduction disturbances after TAVR requires the pre-interventional insertion of a temporary pacemaker (TP). However, this approach poses risks, including the risk of infection. For this reason, the following study aimed to investigate microbial growth on temporary pacemaker leads and its association with outcome post-TAVR and to identify associated pathogens and related risk factors. METHODS A prospective study was conducted including 344 patients undergoing TAVR at the Heart Centre Bonn. Of these, 97 patients did not require TP leads as they already had permanent pacemakers; this group was considered as comparison group. The TP leads of the remaining 247 patients were removed, sonicated, and cultured to investigate bacterial growth over a period of 14 days. Finally, we compared patients without microbial growth (n = 184) and patients with microbial growth (n = 63). The primary endpoint of the study was 30-day all-cause mortality, secondary endpoints were periprocedural infections, the length of the postprocedural hospital stay, 30-day major vascular complications and the 30-day stroke rate. RESULTS The majority of cases (74.5%) showed no bacterial growth. In the remaining cases (25.5%), diverse microorganisms were identified, mostly non-pathogenic bacteria. The statistical analysis revealed no significant differences between groups according to microbial growth in terms of 30-day mortality (p = 0.446), postprocedural hospital stay (p = 0.401), periprocedural infections (p = 0.434), 30-day major vascular complications (p = 1.0), and 30-day stroke rate (p = 1.0). Notably, the timing of sheath insertion was significantly associated with microbial growth; sheath placement more than 2 days prior to the procedure was associated with a significantly higher risk of microbial growth (OR: 2.1; 95% CI 1.1-4.3) (p = 0.030). CONCLUSIONS The presence of temporary leads does not significantly impact clinical outcomes, irrespective of bacterial growth on the lead. However, the timing and duration of sheath placement plays a crucial role in contamination incidence. Thus, temporary leads/sheaths should be placed shortly before the procedure and removed promptly to reduce the risk of contamination/infection.
Collapse
Affiliation(s)
- Mustafa Mousa Basha
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| | - Baravan Al-Kassou
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Christopher Gestrich
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Marcel Weber
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Thomas Beiert
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Farhad Bakhtiary
- Department of Cardiac Surgery, Heart Center Bonn, University Hospital Bonn, Bonn, Germany
| | - Georg Nickenig
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Sebastian Zimmer
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Jasmin Shamekhi
- Department of Medicine II, Heart Center Bonn, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
3
|
Stefańczyk P, Nowosielecka D, Polewczyk A, Jacheć W, Głowniak A, Kosior J, Kutarski A. Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:291. [PMID: 36612613 PMCID: PMC9819767 DOI: 10.3390/ijerph20010291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/21/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND Upgrading from pacemakers to ICDs and CRTs is a difficult procedure, and often, transvenous lead extraction (TLE) is necessary for venous access. TLE is considered riskier in patients with multiple diseases. We aimed to assess the complexity, risk, and outcome of TLE among CRT and ICD candidates. METHODS We analyzed clinical data from 2408 patients undergoing TLE between 2006 and 2021. There were 138 patients upgraded to CRT-D, 33 patients upgraded to CRT-P and 89 individuals upgraded to ICD versus 2148 patients undergoing TLE for other non-infectious indications. RESULTS The need for an upgrade was the leading indication for TLE in only 36-66% of patients. In 42.0-57.6% of patients, the upgrade procedure could be successfully done only after reestablishing access to the occluded vein. All leads were extracted in 68.1-76.4% of patients, functional leads were retained in 20.2-31.9%, non-functional leads were left in place in 0.0-1.1%, and non-functional superfluous leads were extracted in 3.6-8.4%. The long-term survival rate of patients in the CRT-upgrade group was lower (63.8%) than in the non-upgrade group (75.2%). CONCLUSIONS Upgrading a patient from an existing pacemaker to an ICD/CRT is feasible in 100% of cases, provided that TLE is performed for venous access. Major complications of TLE at the time of device upgrade are rare and, if present do not result in death.
Collapse
Affiliation(s)
- Paweł Stefańczyk
- Department of Cardiology, Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Dorota Nowosielecka
- Department of Cardiology, Pope John Paul II Province Hospital, 22-400 Zamość, Poland
- Department of Cardiac Surgery, Pope John Paul II Province Hospital, 22-400 Zamość, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology, Institute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland
- Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, 25-736 Kielce, Poland
| | - Wojciech Jacheć
- 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Silesian Medical University in Katowice, 41-800 Zabrze, Poland
| | - Andrzej Głowniak
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| | - Jarosław Kosior
- Department of Cardiology, Masovian Specialist Hospital, 26-617 Radom, Poland
| | - Andrzej Kutarski
- Department of Cardiology, Medical University, 20-059 Lublin, Poland
| |
Collapse
|
4
|
Empfehlungen zur Sondenextraktion – Gemeinsame Empfehlungen der Deutschen Gesellschaft für Kardiologie (DGK) und der Deutschen Gesellschaft für Thorax‑, Herz- und Gefäßchirurgie (DGTHG). ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2022. [DOI: 10.1007/s00398-022-00512-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
5
|
Diaz JC, Romero J, Costa R, Cuesta A, Biase LD, Alviz I, Velasco A, Gabr M, Duque M, Marin JE, Aristizabal J, Velasquez J, Niño CD, Mazzetti H. Current practice in transvenous lead extraction in Latin America: Latin American Heart Rhythm Association survey. J Cardiovasc Electrophysiol 2021; 32:2715-2721. [PMID: 34288220 DOI: 10.1111/jce.15180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/19/2021] [Accepted: 07/02/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Transvenous lead extraction (TLE) is standard of care for the management of patients with cardiac implantable electronic device infection or lead-related complications. Currently, objective data on TLE in Latin America is lacking. OBJECTIVE To describe the current practice standards in Latin American centers performing TLE. METHODS An online survey was sent through the mailing list of the Latin American Heart Rhythm Society. Online reminders were sent through the mailing list; duplicate answers were discarded. The survey was available for 1 month, after which no more answers were accepted. RESULTS A total of 48 answers were received, from 44 different institutions (39.6% from Colombia, 27.1% from Brazil), with most respondents (82%) being electrophysiologists. Twenty-nine institutions (66%) performed <10 lead extractions/year, with 7 (16%) institutions not performing lead extraction. Although most institutions in which lead extraction is performed reported using several tools, mechanical rotating sheaths were cited as the main tool (66%) and only 13% reported the use of laser sheaths. Management of infected leads was performed according to current guidelines. CONCLUSION This survey is the first attempt to provide information on TLE procedures in Latin America and could provide useful information for future prospective registries. According to our results, the number of centers performing high volume lead extraction in Latin America is smaller than that reported in other continents, with most interventions performed using mechanical tools. Future prospective registries assessing acute and long-term success are needed.
Collapse
Affiliation(s)
| | - Jorge Romero
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Roberto Costa
- Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, Sao Paulo, Brazil
| | - Alejandro Cuesta
- Facultad de Medicina, Centro Cardiovascular Universitario, Hospital de Clínicas, Universidad de la República, Montevideo, Uruguay
| | - Luigi D Biase
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Isabella Alviz
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Alejandro Velasco
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Mohamed Gabr
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | | | - Jorge E Marin
- Hospital Universitario San Vicente Fundación, Rionegro, Colombia
| | | | | | | | - Hector Mazzetti
- Sanatorio de La Trinidad de San Isidro, Buenos Aires, Argentina
| |
Collapse
|
6
|
Zerbo S, Perrone G, Bilotta C, Adelfio V, Malta G, Di Pasquale P, Maresi E, Argo A. Cardiovascular Implantable Electronic Device Infection and New Insights About Correlation Between Pro-inflammatory Markers and Heart Failure: A Systematic Literature Review and Meta-Analysis. Front Cardiovasc Med 2021; 8:602275. [PMID: 34012983 PMCID: PMC8126630 DOI: 10.3389/fcvm.2021.602275] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 03/16/2021] [Indexed: 11/28/2022] Open
Abstract
Introduction: Surgical approaches to treat patients with abnormal pro-inflammatory parameters remain controversial, and the debate on the correlation between hematological parameter alteration in cardiac implantable electronic device (CIED) infection and the increase in mortality continues. Methods: We performed a systematic review using the PubMed, Scopus, and Cochrane Library databases. Twenty-two articles from May 2007 to April 2020 were selected and divided according to the following topics: prevalence of microbes in patients with CIED infection; characteristics of patients with CIED infection; comparison between patients who underwent and did not undergo replantation after device extraction; and correlation between alteration of hematological parameters and poor prognosis analysis. Results: Epidemiological analysis confirmed high prevalence of male sex, staphylococcal infection, and coagulase-negative staphylococci (CoNS). The most common comorbidity was heart failure. Complete removal of CIED and antimicrobial therapy combination are the gold standard. CIED replacement was associated with higher survival. High preoperative white blood cell count and C-reactive protein levels increased the risk of right ventricular failure (RVF) development. Increased red blood cell distribution width (RDW) value or decreased platelet count was correlated with poor prognosis. No correlation was noted between preoperative leukocytosis and CIED infection. Discussion: A relevant correlation between leukocytosis and RVF was observed. Heart failure may be related to high RDW values and decreased platelet count. Data on the correlation between hematological parameter alteration and poor prognosis are missing in many studies because of delayed implantation in patients showing signs of infection.
Collapse
Affiliation(s)
- Stefania Zerbo
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, Italy
| | - Giulio Perrone
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, Italy
| | - Clio Bilotta
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, Italy
| | - Valeria Adelfio
- Department of Economics, Business and Statistics, University of Palermo, Palermo, Italy
| | - Ginevra Malta
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, Italy
| | - Pietro Di Pasquale
- Division of Cardiology, Paolo Borsellino, G.F. Ingrassia Hospital, Palermo, Italy
| | - Emiliano Maresi
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, Italy
| | - Antonina Argo
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Section of Legal Medicine, University of Palermo, Palermo, Italy
| |
Collapse
|
7
|
Persistent Cutibacterium (Formerly Propionibacterium) acnes Bacteremia and Refractory Endocarditis in a Patient with Retained Implantable Pacemaker Leads. Case Rep Infect Dis 2020; 2020:8883907. [PMID: 32774952 PMCID: PMC7399732 DOI: 10.1155/2020/8883907] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 06/16/2020] [Accepted: 07/07/2020] [Indexed: 11/29/2022] Open
Abstract
Cutibacterium (formerly Propionibacterium) acnes (C. acnes) is a commensal bacteria commonly found on the human skin and in the mouth. While the virulence of C. acnes is low in humans, it does produce a biofilm and has been identified as an etiologic agent in a growing number of implant-associated infections. C. acnes infections can prove diagnostically challenging as laboratory cultures can often take greater than 5 days to yield positive results, which are then often disregarded as contaminant. Patients with recurrent bacteremia in the setting of implantable devices warrant further studies to evaluate for an associated valvular or lead endocarditis. The patient in this report demonstrates how cardiac device-related endocarditis secondary to C. acnes can be overlooked due to the indolent nature of this pathogen. This patient presented with an implanted cardiac pacemaker device, as well as retained leads from a prior pacemaker. Transesophageal echocardiography was required to confirm the diagnosis in the setting of multiple positive blood cultures and negative transthoracic echocardiograms over a period of 4 years. The purpose of this report is to highlight the difficulties encountered in diagnosing C. acnes endocarditis in a patient with a cardiac implantable electronic device and persistently positive blood cultures.
Collapse
|
8
|
Arora Y, Perez AA, Carrillo RG. Influence of vegetation shape on outcomes in transvenous lead extractions: Does shape matter? Heart Rhythm 2020; 17:646-653. [DOI: 10.1016/j.hrthm.2019.11.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Indexed: 10/25/2022]
|
9
|
Abstract
Historically, MRI was contraindicated in patients with cardiovascular implantable electronic devices because the devices' metallic components made this imaging study unsafe. Advances over the last decade have now made MRI safe for many of these patients. This article examines the risks of MRI technology for this patient population and reviews recent guidelines from the Heart Rhythm Society.
Collapse
Affiliation(s)
- Desiree M Soto
- Desiree M. Soto is the electrophysiology nurse coordinator at the Jefferson Heart Institute in Philadelphia, Pa
| |
Collapse
|
10
|
Lu WD, Chen JY. Proposed treatment algorithm for cardiac device-related subclavian vein stenosis: a case series. EUROPEAN HEART JOURNAL-CASE REPORTS 2020; 4:1-6. [PMID: 32128496 PMCID: PMC7047064 DOI: 10.1093/ehjcr/ytz245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/22/2019] [Accepted: 12/19/2019] [Indexed: 11/20/2022]
Abstract
Background Subclavian vein obstruction may occur in patients with pacemaker leads, which may make the implantation of new pacemaker leads difficult. Case summary We report two cases in which upgrading to cardiac resynchronization therapy pacemaker was challenging due to total central vein occlusion. In the first case, a 78-year-old woman with permanent pacemaker implantation, 5 years ago, was successfully treated by balloon venoplasty. In the second case, balloon venoplasty was unsuccessful in a 46-year-old woman who has received twice single-chamber implantable cardioverter-defibrillator, 12 years and 5 years ago, due to vessel crowding, so a contralateral side puncture, along with a tunnel technique, was performed to solve this problem. Discussion Cardiac implantable electronic device-related subclavian vein stenosis can present a challenge to common cardiac resynchronization therapy device upgrades in the absence of appropriate techniques.
Collapse
Affiliation(s)
- Wei-Da Lu
- Division of Cardiology, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Road, Tainan 704, Taiwan
| | - Ju-Yi Chen
- Division of Cardiology, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Road, Tainan 704, Taiwan
| |
Collapse
|
11
|
Jacheć W, Polewczyk A, Segreti L, Bongiorni MG, Kutarski A. To abandon or not to abandon: Late consequences of pacing and ICD lead abandonment. Pacing Clin Electrophysiol 2019; 42:1006-1017. [DOI: 10.1111/pace.13715] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 04/25/2019] [Accepted: 04/26/2019] [Indexed: 11/30/2022]
Affiliation(s)
- Wojciech Jacheć
- 2nd Department of CardiologyMedical University of Silesia, School of Medicine with the Division of Dentistry in Zabrze Zabrze Poland
| | - Anna Polewczyk
- Faculty of Medicine and Health Sciences KielceThe Jan Kochanowski University Kielce Poland
- Swietokrzyskie Cardiology Center Kielce Poland
| | - Luca Segreti
- Department of CardiologyUniversity Hospital of Pisa Pisa Italy
| | | | | |
Collapse
|
12
|
Satish M, Mumtaz MA, Bittner MJ, Valenta C. Stenotrophomonas maltophilia Endocarditis of an Implantable Cardioverter Defibrillator Lead. Cureus 2019; 11:e4165. [PMID: 31065471 PMCID: PMC6497185 DOI: 10.7759/cureus.4165] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Stenotrophomonas maltophilia (S. maltophilia) is a nosocomial pathogen and a rare cause of infective endocarditis (IE). Given the intrinsic resistance to many classes of antibiotics, IE due to S. maltophilia carries significant morbidity and mortality among the cases described. Prompt identification of risk factors, particularly the use of medical devices, is necessary for the timely identification of this organism and prompt medical management. We report a case of an implantable cardioverter defibrillator (ICD) lead associated IE due to S. maltophilia and discuss the diagnosis, treatment and outcomes in relation to existing evidence.
Collapse
Affiliation(s)
- Mohan Satish
- Internal Medicine, Creighton University Medical Center, Omaha, USA
| | | | - Marvin J Bittner
- Internal Medicine, Creighton University Medical Center, Omaha, USA
| | - Carrie Valenta
- Hospital Medicine, Creighton University Medical Center, Omaha, USA
| |
Collapse
|