Kewcharoen J, Shah K, Bhardwaj R, Contractor T, Turagam MK, Mandapati R, Lakkireddy D, Garg J. New-generation electronic appliances and cardiac implantable electronic devices: a systematic literature review of mechanisms and in vivo studies. J Interv Card Electrophysiol 2024; 67:1709-1720. [PMID: 38443707 DOI: 10.1007/s10840-024-01777-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 02/27/2024] [Indexed: 03/07/2024]
Abstract
INTRODUCTION Cardiac implantable electronic device (CIED) functions are susceptible to electromagnetic interference (EMI) from electromagnetic fields (EMF). Data on EMI risks from new-generation electronic appliances (EA) are limited. OBJECTIVE We performed a systematic literature review on the mechanisms of EMI, current evidence, and recently published trials evaluating the effect of EMF on CIEDs from electric vehicles (EV), smartphone, and smartwatch technology and summarize its safety data. METHODS Electronic databases, including PubMed and EMBASE, were searched for in vivo studies evaluating EMF strength and incidence between CIEDs and commercial EVs, new-generation smartphones, and new-generation smartwatches. RESULTS A total of ten studies (three on EVs, five on smartphones, one on smartphones, one on smartphones and smartwatches) were included in our systematic review. There was no report of EMI incidence associated with EVs or smartwatches. Magnet-containing smartphones (iPhone 12) can cause EMI when placed directly over CIEDs - thereby triggering the magnet mode; otherwise, no report of EMI was observed with other positions or smartphone models. CONCLUSION Current evidence suggests CIED recipients are safe from general interaction with EVs/HEVs, smartphones, and smartwatches. Strictly, results may only be applied to commercial brands or models tested in the published studies. There is limited data on EMI risk from EVs wireless charging and smartphones with MagSafe technology.
Collapse
Affiliation(s)
- Jakrin Kewcharoen
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | - Kuldeep Shah
- Division of Cardiology, Cardiac Arrhythmia Service, MercyOne Siouxland Heart and Vascular Center, Sioux City, IA, USA
| | - Rahul Bhardwaj
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | - Tahmeed Contractor
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | - Mohit K Turagam
- Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Ravi Mandapati
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA
| | | | - Jalaj Garg
- Division of Cardiology, Cardiac Arrhythmia Service, Loma Linda University Health, 11234 Anderson St, Loma Linda, CA, 92354, USA.
| |
Collapse
|
2
|
Strik M, Ploux S, van der Zande J, Velraeds A, Fontagne L, Haïssaguerre M, Bordachar P. The Use of Electrocardiogram Smartwatches in Patients with Cardiac Implantable Electrical Devices. SENSORS (BASEL, SWITZERLAND) 2024; 24:527. [PMID: 38257619 PMCID: PMC10818505 DOI: 10.3390/s24020527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 01/02/2024] [Accepted: 01/12/2024] [Indexed: 01/24/2024]
Abstract
Unlimited access to ECGs using an over-the-counter smartwatch constitutes a real revolution for our discipline, and the application is rapidly expanding to include patients with cardiac implantable electronic devices (CIEDs) such as pacemakers (PMs) and implantable cardioverter defibrillators (ICDs). CIEDs require periodic evaluation and adjustment by healthcare professionals. In addition, implanted patients often present with symptoms that may be related to their PMs or ICDs. An ECG smartwatch could reveal information about device functioning, confirm normal device function, or aid in the case of device troubleshooting. In this review, we delve into the available evidence surrounding smartwatches with ECG registration and their integration into the care of patients with implanted pacemakers and ICDs. We explore safety considerations and the benefits and limitations associated with these wearables, drawing on relevant studies and case series from our own experience. By analyzing the current landscape of this emerging technology, we aim to provide a comprehensive overview that facilitates informed decision-making for both healthcare professionals and patients.
Collapse
Affiliation(s)
- Marc Strik
- Cardio-Thoracic Unit, Bordeaux University Hospital (CHU), F-33600 Pessac-Bordeaux, France; (S.P.); (M.H.); (P.B.)
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
| | - Sylvain Ploux
- Cardio-Thoracic Unit, Bordeaux University Hospital (CHU), F-33600 Pessac-Bordeaux, France; (S.P.); (M.H.); (P.B.)
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
| | - Joske van der Zande
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
- Cardiovascular and Respiratory Physiology, Twente University, 7522 NB Enschede, The Netherlands
| | - Anouk Velraeds
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
- Cardiovascular and Respiratory Physiology, Twente University, 7522 NB Enschede, The Netherlands
| | - Leslie Fontagne
- Cardio-Thoracic Unit, Bordeaux University Hospital (CHU), F-33600 Pessac-Bordeaux, France; (S.P.); (M.H.); (P.B.)
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
| | - Michel Haïssaguerre
- Cardio-Thoracic Unit, Bordeaux University Hospital (CHU), F-33600 Pessac-Bordeaux, France; (S.P.); (M.H.); (P.B.)
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
| | - Pierre Bordachar
- Cardio-Thoracic Unit, Bordeaux University Hospital (CHU), F-33600 Pessac-Bordeaux, France; (S.P.); (M.H.); (P.B.)
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, F-33600 Pessac-Bordeaux, France; (J.v.d.Z.); (A.V.)
| |
Collapse
|
3
|
Masoumian Hosseini M, Masoumian Hosseini ST, Qayumi K, Hosseinzadeh S, Sajadi Tabar SS. Smartwatches in healthcare medicine: assistance and monitoring; a scoping review. BMC Med Inform Decis Mak 2023; 23:248. [PMID: 37924029 PMCID: PMC10625201 DOI: 10.1186/s12911-023-02350-w] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 10/22/2023] [Indexed: 11/06/2023] Open
Abstract
Smartwatches have become increasingly popular in recent times because of their capacity to track different health indicators, including heart rate, patterns of sleep, and physical movements. This scoping review aims to explore the utilisation of smartwatches within the healthcare sector. According to Arksey and O'Malley's methodology, an organised search was performed in PubMed/Medline, Scopus, Embase, Web of Science, ERIC and Google Scholar. In our search strategy, 761 articles were returned. The exclusion/inclusion criteria were applied. Finally, 35 articles were selected for extracting data. These included six studies on stress monitoring, six on movement disorders, three on sleep tracking, three on blood pressure, two on heart disease, six on covid pandemic, three on safety and six on validation. The use of smartwatches has been found to be effective in diagnosing the symptoms of various diseases. In particular, smartwatches have shown promise in detecting heart diseases, movement disorders, and even early signs of COVID-19. Nevertheless, it should be emphasised that there is an ongoing discussion concerning the reliability of smartwatch diagnoses within healthcare systems. Despite the potential advantages offered by utilising smartwatches for disease detection, it is imperative to approach their data interpretation with prudence. The discrepancies in detection between smartwatches and their algorithms have important implications for healthcare use. The accuracy and reliability of the algorithms used are crucial, as well as high accuracy in detecting changes in health status by the smartwatches themselves. This calls for the development of medical watches and the creation of AI-hospital assistants. These assistants will be designed to help with patient monitoring, appointment scheduling, and medication management tasks. They can educate patients and answer common questions, freeing healthcare providers to focus on more complex tasks.
Collapse
Affiliation(s)
- Mohsen Masoumian Hosseini
- Department of E-Learning in Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran
- CyberPatient Research Affiliate, Interactive Health International, Department of the surgery, University of British Columbia, Vancouver, Canada
| | - Seyedeh Toktam Masoumian Hosseini
- CyberPatient Research Affiliate, Interactive Health International, Department of the surgery, University of British Columbia, Vancouver, Canada.
- Department of Nursing, School of Nursing and Midwifery, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran.
| | - Karim Qayumi
- Professor at Department of Surgery, University of British Columbia, Vancouver, Canada
| | - Shahriar Hosseinzadeh
- CyberPatient Research Coordinator, Interactive Health International, Department of Surgery, University of British Columbia, Vancouver, Canada
| | | |
Collapse
|
4
|
Ha GB, Steinberg BA, Freedman R, Bayés-Genís A, Sanchez B. Safety evaluation of smart scales, smart watches, and smart rings with bioimpedance technology shows evidence of potential interference in cardiac implantable electronic devices. Heart Rhythm 2023; 20:561-571. [PMID: 36997272 DOI: 10.1016/j.hrthm.2022.11.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/21/2022] [Accepted: 11/27/2022] [Indexed: 02/24/2023]
Abstract
BACKGROUND Smart scales, smart watches, and smart rings with bioimpedance technology may create interference in patients with cardiac implantable electronic devices (CIEDs). OBJECTIVES The purpose of this study was to determine interference at CIEDs with simulations and benchtop testing, and to compare the results with maximum values defined in the ISO 14117 electromagnetic interference standard for these devices. METHODS The interference at pacing electrodes was determined by simulations on a male and a female computable model. A benchtop evaluation of representative CIEDs from 3 different manufacturers as specified in the ISO 14117 standard also was performed. RESULTS Simulations showed evidence of interference with voltage values exceeding threshold values defined in the ISO 14117 standard. The level of interference varied with the frequency and amplitude of the bioimpedance signal, and between male and female models. The level of interference generated with smart scale and smart rings simulations was lower than with smart watches. Across device manufacturers, generators demonstrated susceptibility to oversensing and pacing inhibition at different signal amplitudes and frequencies. CONCLUSIONS This study evaluated the safety of smart scales, smart watches, and smart rings with bioimpedance technology via simulation and testing. Our results indicate that these consumer electronic devices could interfere in patients with CIEDs. The present findings do not recommend the use of these devices in this population due to potential interference.
Collapse
Affiliation(s)
- Gia-Bao Ha
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah
| | - Benjamin A Steinberg
- Department of Medicine, University of Utah Health Sciences Center, Salt Lake City, Utah
| | - Roger Freedman
- Department of Medicine, University of Utah Health Sciences Center, Salt Lake City, Utah
| | - Antoni Bayés-Genís
- Department of Cardiology, Heart Institute, Hospital Universitari Germans Trias i Pujol, Badalona, Spain; Centro de Investigación Biomédica en Red Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain; Autonomous University of Barcelona, Barcelona, Spain
| | - Benjamin Sanchez
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
5
|
Saha N, Millward JM, Herrmann CJJ, Rahimi F, Han H, Lacour P, Blaschke F, Niendorf T. High-Fidelity 3D Stray Magnetic Field Mapping of Smartphones to Address Safety Considerations with Active Implantable Electronic Medical Devices. SENSORS (BASEL, SWITZERLAND) 2023; 23:1209. [PMID: 36772249 PMCID: PMC9919430 DOI: 10.3390/s23031209] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/07/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
Case reports indicate that magnets in smartphones could be a source of electromagnetic interference (EMI) for active implantable medical devices (AIMD), which could lead to device malfunction, compromising patient safety. Recognizing this challenge, we implemented a high-fidelity 3D magnetic field mapping (spatial resolution 1 mm) setup using a three-axis Hall probe and teslameter, controlled by a robot (COSI Measure). With this setup, we examined the stray magnetic field of an iPhone 13 Pro, iPhone 12, and MagSafe charger to identify sources of magnetic fields for the accurate risk assessment of potential interferences with AIMDs. Our measurements revealed that the stray fields of the annular array of magnets, the wide-angle camera, and the speaker of the smartphones exceeded the 1 mT limit defined by ISO 14117:2019. Our data-driven safety recommendation is that an iPhone 13 Pro should be kept at least 25 mm away from an AIMD to protect it from unwanted EMI interactions. Our study addresses safety concerns due to potential device-device interactions between smartphones and AIMDs and will help to define data-driven safety guidelines. We encourage vendors of electronic consumer products (ECP) to provide information on the magnetic fields of their products and advocate for the inclusion of smartphones in the risk assessment of EMI with AIMDs.
Collapse
Affiliation(s)
- Nandita Saha
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
| | - Jason M. Millward
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
| | - Carl J. J. Herrmann
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Department of Physics, Humboldt University of Berlin, 10117 Berlin, Germany
| | - Faezeh Rahimi
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Chair of Medical Engineering, Technische Universität Berlin, 10623 Berlin, Germany
| | - Haopeng Han
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
| | - Philipp Lacour
- Department of Cardiology, Charité—Universitätsmedizin Berlin, Campus Virchow-Klinikum, 13353 Berlin, Germany
| | - Florian Blaschke
- Department of Cardiology, Charité—Universitätsmedizin Berlin, Campus Virchow-Klinikum, 13353 Berlin, Germany
| | - Thoralf Niendorf
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
| |
Collapse
|
6
|
Nowak B, Przibille O, Napp A. [Electromagnetic interference : Pacemakers, cardiac resynchronization therapy devices, implantable cardioverter-defibrillator]. Herzschrittmacherther Elektrophysiol 2022; 33:297-304. [PMID: 35781834 DOI: 10.1007/s00399-022-00875-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 06/13/2022] [Indexed: 06/15/2023]
Abstract
Patients with cardiac pacemakers, implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy devices (CRT) are exposed to different types of electromagnetic interference (EMI) at home and at work. Due to the constantly increasing role of electrically active appliances in daily use and the introduction of new therapy concepts such as the leadless cardiac pacemaker and the subcutaneous defibrillator, this topic is of great relevance. The further development of the implanted devices and the almost complete use of bipolar leads has reduced the overall risk of EMI. This review article provides information about the current status of possible interference in the private environment and how to avoid it. In addition, information is provided on how to deal with occupational sources of interference.
Collapse
Affiliation(s)
- Bernd Nowak
- Cardioangiologisches Centrum Bethanien, Im Prüfling 23, 60389, Frankfurt a.M., Deutschland.
| | - Oliver Przibille
- Cardioangiologisches Centrum Bethanien, Im Prüfling 23, 60389, Frankfurt a.M., Deutschland
| | - Andreas Napp
- Medizinische Klinik I, - Kardiologie, Angiologie und Internistische Intensivmedizin, Uniklinik RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Deutschland
| |
Collapse
|
7
|
Vanneman M, Kothari P, Bodmer NJ, Convissar D, Desai GA, Kumar N, Iyer MH, Neuburger PJ, Essandoh MK, Cronin B, Dalia AA. The Year in Electrophysiology: Selected Highlights from 2021. J Cardiothorac Vasc Anesth 2022; 36:1526-1539. [DOI: 10.1053/j.jvca.2022.01.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 01/28/2022] [Indexed: 11/11/2022]
|
8
|
Nadeem F, Tran CT, Torbey E, Philbin D, Morales C, Wu M. Interference by Modern Smartphones and Accessories with Cardiac Pacemakers and Defibrillators. Curr Cardiol Rep 2022; 24:347-353. [PMID: 35084671 PMCID: PMC8979866 DOI: 10.1007/s11886-022-01653-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/15/2021] [Indexed: 11/25/2022]
Abstract
Purpose of Review The risk of cardiac implantable electronic device (CIED) interference from cell phones was previously thought to be low based on older studies. Current generation of smartphones have incorporated more magnets for optimization of wireless charging, attachment of accessories, and convenience functionalities. These magnets have the potential to cause CIEDs to inadvertently revert into magnet mode. The purpose of this review is to summarize recent findings on smartphones and their accessories causing interference on CIEDs. Recent Findings Recent reports have demonstrated that the iPhone 12 series and accessories have the capability to cause CIED magnetic interference. Summary Current generation of smartphones, smartwatches, wireless headphones, and accessories have the potential to cause CIEDs to revert into magnet mode in both in vivo and ex vivo experiments. The risk of a clinically significant event is unlikely as long as the Food and Drug Administration (FDA) recommendations are followed; keeping smartphones and accessories at least six inches away from CIEDs.
Collapse
Affiliation(s)
- Fahd Nadeem
- Division of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA
| | - Cao Thach Tran
- Division of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA
| | - Estelle Torbey
- Division of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA
| | - Daniel Philbin
- Division of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA
| | - Carlos Morales
- Division of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA
| | - Michael Wu
- Division of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA.
| |
Collapse
|
9
|
Magnetic field-induced interactions between phones containing magnets and cardiovascular implantable electronic devices: Flip it to be safe? Heart Rhythm 2021; 19:372-380. [PMID: 34767986 DOI: 10.1016/j.hrthm.2021.11.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/19/2021] [Accepted: 11/04/2021] [Indexed: 11/20/2022]
Abstract
BACKGROUND Recent case reports and small studies have reported activation of the magnet-sensitive switches in cardiovascular implantable electronic devices (CIEDs) by the new iPhone 12 series, initiating asynchronous pacing in pacemakers and suspension of antitachycardia therapies in implantable cardioverter-defibrillators (ICDs). OBJECTIVE The purpose of this prospective single-center observational study was to quantify the risk of magnetic field interactions of the iPhone 12 with CIEDs. METHODS A representative model of each CIED series from all manufacturers was tested ex vivo. Incidence and minimum distance necessary for magnet mode triggering were analyzed in 164 CIED patients with either the front or the back of the phone facing the device. The magnetic field of the iPhone 12 was analyzed using a 3-axis Hall probe. RESULTS Ex vivo, magnetic interference occurred in 84.6% with the back compared to 46.2% with the front of the iPhone 12 facing the CIED. In vivo, activation of the magnet-sensitive switch occurred in 30 CIED patients (18.3%; 21 pacemaker, 9 ICD) when the iPhone 12 was placed in close proximity over the CIED pocket and the back of the phone was facing the skin. Multiple binary logistic regression analysis identified implantation depth (95% confidence interval 0.02-0.24) as an independent predictor of magnet-sensitive switch activation. CONCLUSION Magnetic field interactions occur only in close proximity and with precise alignment of the iPhone 12 and CIEDs. It is important to advise CIED patients to not put the iPhone 12 directly on the skin above the CIED. Further recommendations are not necessary.
Collapse
|
10
|
Nadeem F, Nunez Garcia A, Thach Tran C, Wu M. Magnetic Interference on Cardiac Implantable Electronic Devices From Apple iPhone MagSafe Technology. J Am Heart Assoc 2021; 10:e020818. [PMID: 34074132 PMCID: PMC8477860 DOI: 10.1161/jaha.121.020818] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Magnet wireless charging is being utilized increasingly in current generation smartphones. Apple's MagSafe is a proprietary wireless charging technology with an array of magnets that has the capacity to generate magnet fieldstrength >50 gauss (G). We hypothesize that there is clinically significant magnet interference caused by Apple's MagSafe technology on cardiac implantable electronic devices (CIED). Methods and Results This study has an in vivo and an ex vivo component. The in vivo component consists of consecutive patients who presented to the electrophysiology laboratory with previously implanted CIEDs. The iPhone 12 Pro Max was directly placed on the skin over the pocket of these patients and the effect was studied by device interrogation. For the ex vivo component of the study, CIEDs from major device companies were tested for magnetic interference caused by iPhone 12 Pro Max through unopened packages. We found that iPhone 12 Pro Max resulted in clinically identifiable magnet interference in 3/3 (100%) participants in vivo and in 8/11 (72.7%) devices ex vivo. Conclusions Apple's iPhone 12 Pro Max MagSafe technology can cause magnet interference on CIEDs and has the potential to inhibit lifesaving therapy.
Collapse
Affiliation(s)
- Fahd Nadeem
- Division of Cardiology Department of Medicine Lifespan Cardiovascular Institute and Brown University Providence RI
| | - Arismendy Nunez Garcia
- Division of Cardiology Department of Medicine Lifespan Cardiovascular Institute and Brown University Providence RI
| | - Cao Thach Tran
- Division of Cardiology Department of Medicine Lifespan Cardiovascular Institute and Brown University Providence RI
| | - Michael Wu
- Division of Cardiology Department of Medicine Lifespan Cardiovascular Institute and Brown University Providence RI
| |
Collapse
|
11
|
Greenberg JC, Altawil MR, Singh G. Letter to the Editor-Lifesaving therapy inhibition by phones containing magnets. Heart Rhythm 2021; 18:1040-1041. [PMID: 33418126 DOI: 10.1016/j.hrthm.2020.12.032] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 12/29/2020] [Accepted: 12/31/2020] [Indexed: 10/22/2022]
Affiliation(s)
- Joshua C Greenberg
- Section of Cardiac Electrophysiology, Henry Ford Heart and Vascular Institute, Henry Ford Hospital, Detroit, Michigan
| | - Mahmoud R Altawil
- Section of Cardiac Electrophysiology, Henry Ford Heart and Vascular Institute, Henry Ford Hospital, Detroit, Michigan
| | - Gurjit Singh
- Section of Cardiac Electrophysiology, Henry Ford Heart and Vascular Institute, Henry Ford Hospital, Detroit, Michigan.
| |
Collapse
|
12
|
|
13
|
Stört das Handy den Herzschrittmacher? Dtsch Med Wochenschr 2020. [DOI: 10.1055/a-1206-4887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|