Ye Y, Yi W, Fan S, Zhao L, Yu Y, Lu Y, Yao Q, Wang W, Chang S. Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load : A finite element analysis. J Orofac Orthop 2023; 84:79-87. [PMID: 34581834 DOI: 10.1007/s00056-021-00351-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 08/11/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE We have been developing a new type of miniscrew to specifically withstand orthodontic torque load. This study aimed to investigate the effect of thread depth and thread pitch on the primary stability of these miniscrews if stressed with torque load. METHODS Finite element analysis (FEA) was used to evaluate the primary stability of the miniscrews. For thread depth analysis, the thread depth was set to 0.1-0.4 mm to construct 7 models. For thread pitch analysis, the thread pitch was set to 0.4-1.0 mm to construct another 7 models. A torque load of 6 Nmm was applied to the miniscrew, and the other parameters were kept constant for the analyses. Maximum equivalent stress (Max EQV) of cortical bone and maximum displacement of the miniscrews (Max DM) were the indicators for primary stability of the miniscrew in the 14 models. RESULTS In the thread depth analysis, Max DM increased as the miniscrew thread depth increased, while Max EQV was smallest in model 3 (thread depth = 0.2, Max EQV = 8.91 MPa). In the pitch analysis, with an increase of the thread pitch, Max DM generally exhibited a trend to increase, while Max EQV of cortical bone showed a general trend to decrease. CONCLUSION Considering the data of Max DM and Max EQV, the most appropriate thread depth and thread pitch of the miniscrews in our model was 0.2 and 0.7 mm, respectively. This knowledge may effectively improve the primary stability of newly developed miniscrews.
Collapse
Affiliation(s)
- Yushan Ye
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan-jiang Road, 510120, Guangzhou, China
| | - Weimin Yi
- Department of Integrative medicine, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Song Fan
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan-jiang Road, 510120, Guangzhou, China
| | - Luodan Zhao
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan-jiang Road, 510120, Guangzhou, China
| | - Yansong Yu
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan-jiang Road, 510120, Guangzhou, China
| | - Yingjuan Lu
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan-jiang Road, 510120, Guangzhou, China
| | - Qinghe Yao
- School of Engineering, Sun Yat-sen University, No. 135 Xingang West Road, Haizhu District, Guangzhou, China
| | - Wei Wang
- Urumqi DW Innovation Info Tech Co., Ltd, Urumqi, China
| | - Shaohai Chang
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, 107 Yan-jiang Road, 510120, Guangzhou, China.
| |
Collapse
|
2
|
Humphries LS, Reid RR, Ross CF, Taylor AB, Collins JM, Freire AR, Rossi AC, Prado FB. Biomechanical and morphological analysis of Pierre Robin sequence mandible: Finite element and morphometric study. Anat Rec (Hoboken) 2020; 304:1375-1388. [PMID: 33099874 DOI: 10.1002/ar.24543] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 08/19/2020] [Accepted: 08/22/2020] [Indexed: 11/06/2022]
Affiliation(s)
- Laura S Humphries
- Department of Surgery, Section of Plastic and Reconstructive Surgery, University of Chicago Medicine, Chicago, Illinois, USA
| | - Russell R Reid
- Department of Surgery, Section of Plastic and Reconstructive Surgery, University of Chicago Medicine, Chicago, Illinois, USA
| | - Callum F Ross
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, Illinois, USA
| | - Andrea B Taylor
- Department of Basic Science, Touro University, Vallejo, California, USA
| | - John M Collins
- Department of Radiology, University of Chicago Medicine, Chicago, Illinois, USA
| | - Alexandre R Freire
- Department of Biosciences-Anatomy, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Ana Cláudia Rossi
- Department of Biosciences-Anatomy, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Felippe B Prado
- Department of Biosciences-Anatomy, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| |
Collapse
|
3
|
Antunes Junior C, Mercuri EGF, Franco APGDO, Costa M, Karam LZ, Kalinowski HJ, Gomes OMM. Bulk Fill flow resin contraction using 3D finite element model and calibration by Fiber Bragg Grating measurement. Comput Methods Biomech Biomed Engin 2020; 23:1127-1137. [PMID: 32657618 DOI: 10.1080/10255842.2020.1789607] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Contraction due to polymerization of dental resin can cause failure on the adhesive interfaces, can lead to problems such as the appearance of gaps in the interfaces, postoperative sensitivity, pulp damage and the return of the caries. The objective of this work is the study of stresses on the dental adhesive that are generated by the process shrinkage of resin associated with biting forces. A laboratory experiment measured the strains and temperature inside the FiltekTM Bulk Fill Flow resin during the process of polymerization using Fiber Bragg Grating sensors in an ex vivo tooth. From tomographic images a three-dimensional geometric model of the tooth was reconstructed. A pre-tension was calibrated to simulate the residual contraction on the resin 3 D model. Finally, an Finite Element Method analysis was performed to access the adhesive stresses at the interface enamel/dentin with the adhesive, considering as loading the residual polymerization contraction of the dental resin and also biting loads. The model was able to represented the strain obtained in the laboratory experiment. The results of the stress analysis shows that the outer regions of adhesive are more prone to failure, as veried by dental surgeons in clinical practice.
Collapse
Affiliation(s)
- Claudio Antunes Junior
- Programa de Pós-Graduação em Métodos Numéricos em Engenharia, Universidade Federal do Paraná, Curitiba, Brazil
| | | | | | - Manoella Costa
- Departamento de Odontologia, Universidade Estadual de Ponta Grossa, Ponta Grossa, Brazil
| | - Leandro Zen Karam
- Departamento de Engenharia Elétrica e Informática Industrial, Universidade Tecnológica Federal do Paraná, Curitiba, Brazil
| | - Hypolito José Kalinowski
- Departamento de Engenharia de Telecomunicações, Universidade Federal Fluminense, Niterói, Brazil
| | | |
Collapse
|
4
|
Ye YS, Yi WM, Zhuang PL, Liu M, Yu YS, Lu YJ, Yao QH, Wang W, Chang SH. Thread shape affects the stress distribution of torque force on miniscrews: a finite element analysis. Comput Methods Biomech Biomed Engin 2020; 23:1034-1040. [PMID: 32619356 DOI: 10.1080/10255842.2020.1784884] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
This study aimed to investigate the effect of miniscrews thread shape on the stress distribution receiving a torque load. Seven thread shapes (S,V1,V2,B1,B2,R1,R2) models were constructed and a 6 Nmm-torque load was applied. The order of maximum equivalent stress (EQV) value was V1 > V2 > B1 > R1 > R2 > B2 > S. The order of maximum displacement of miniscrew (Max DM) value was S > B2 > R1 = V1 > B1 > V2 > R2. Model R2 may be the most appropriate thread shape affording a torque force.
Collapse
Affiliation(s)
- Yu-Shan Ye
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Wei-Min Yi
- Department of Integrative medicine, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Pei-Lin Zhuang
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Mo Liu
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yan-Song Yu
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ying-Juan Lu
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Qing-He Yao
- School of Engineering, Sun Yat-sen University, Guangzhou, China
| | - Wei Wang
- Urumqi DW Innovation Info Tech Co., Ltd, Urumqi, China
| | - Shao-Hai Chang
- Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
5
|
Three-dimensional evaluation of mandibular midline distraction: A systematic review. J Craniomaxillofac Surg 2018; 46:1883-1892. [PMID: 30249482 DOI: 10.1016/j.jcms.2018.08.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2018] [Revised: 07/24/2018] [Accepted: 08/22/2018] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To provide a literature overview on mandibular midline distraction (MMD) using three-dimensional (3D) imaging analysis techniques. Regarding different distractor types, the focus was on changes in position and/or morphology of the mandibular condyle and temporomandibular joint (TMJ), skeletal effects, dental effects, soft tissue effects, and biomechanical and masticatory effects, specifically on the mandible and TMJ. METHODS Studies up to March 27 2017 were included, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement guidelines, using Embase, Medline OvidSP, Web-of-science, Scopus, Cochrane, and Google Scholar. RESULTS Thirty-one full-text papers were assessed for eligibility and 15 met the inclusion criteria: prospective (2), retrospective (2), case-report (1) and computational analysis (10). All included studies were graded low (level 4-5) for quality of evidence, using the Oxford Centre for Evidence-Based Medicine criteria. CONCLUSION There is a limited number of studies available, with low levels of evidence and small sample sizes. Bone-borne distraction seems preferable when taking skeletal effects into account. Tooth-borne distraction leads to significant dental tipping. Hybrid distractors combined with parasymphyseal step osteotomy seem to be the most stable under functional masticatory loads. The effects of chewing appeared to be marginal during the latency period. No permanent TMJ symptoms were reported, and little is known about soft tissue effects. SYSTEMATIC REVIEW REGISTRATION International Prospective Register of Systematic Reviews, PROSPERO CRD42014010010.
Collapse
|
6
|
Determining the Patient-Specific Optimum Osteotomy Line for Severe Mandibular Retrognathia Patients. J Craniofac Surg 2018. [DOI: 10.1097/scs.0000000000004470] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
|
7
|
Scheiner S, Hellmich C, Müller C, Bonitz L, Kober C. X-ray physics- and bone composition-based estimation of thickness characteristics from clinical mandibular radiographs. Comput Med Imaging Graph 2015; 45:36-46. [PMID: 26253382 DOI: 10.1016/j.compmedimag.2015.06.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Revised: 04/10/2015] [Accepted: 06/29/2015] [Indexed: 10/23/2022]
Abstract
In dentistry, clinical radiographs (also called X-ray images) reflect the intensity loss of an X-ray when being transmitted through the mandibular objects, and this loss is quantified in terms of grey values. While such images are standardly used for pathology detection by the experienced dentist, we here present a new method for getting more quantitative information out of such 2D radiographs, "extending" them into the third dimension. This "extension" requires consistent combination of X-ray physics (namely, X-ray intensity loss quantification along paths orthogonal to the panoramic clinical image and X-ray attenuation averaging for composite materials) with anatomically known upper and lower limits of vascular porosities in cortical and trabecular bone compartments. Correspondingly computed ranges of overall organ thicknesses are extremely narrow, suggesting adequate estimation of thickness characteristics from 2D radiographic panoramas used clinically, while predicted cortical and trabecular thickness ranges vary by ±8.47% and ±16.13%, respectively. The proposed method also identifies variations between thicknesses at similar anatomical locations left and right of the face's symmetry axis, and molar regions turn out to be thicker than those close to incisors. This paves the way to more detailed diagnostic activities, e.g. in combination with Finite Element simulations.
Collapse
Affiliation(s)
- Stefan Scheiner
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Vienna, Austria.
| | - Christian Hellmich
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Vienna, Austria
| | | | - Lars Bonitz
- Department for Cranial and Maxillofacial Surgery, Plastic Operations, Klinikum Dortmund GmbH, University Witten/Herdecke, Germany
| | - Cornelia Kober
- Faculty of Life Sciences, Hamburg University of Applied Sciences, Hamburg, Germany
| |
Collapse
|
8
|
Park H, Choi B, Nguyen J, Fan J, Shafi S, Klokkevold P, Lee M. Anionic carbohydrate-containing chitosan scaffolds for bone regeneration. Carbohydr Polym 2013; 97:587-96. [PMID: 23911489 DOI: 10.1016/j.carbpol.2013.05.023] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Revised: 05/08/2013] [Accepted: 05/13/2013] [Indexed: 12/13/2022]
Abstract
Scaffolds derived from naturally occurring polysaccharides have attracted significant interest in bone tissue engineering due to their excellent biocompatibility and hydrophilic nature favorable for cell attachment. In this study, we developed composite chitosan (CH) scaffolds containing anionic carbohydrate, such as chondroitin 4-sulfate (CS) or alginate (AG), with biomimetic apatite layer on their surfaces, and investigate their capacity to deliver progenitor cells (bone marrow stromal cells, BMSC) and model proteins with net-positive (histone) and net-negative charge (bovine serum albumin, BSA). The incorporation of CS or AG in CH scaffolds increased compressive modulus of the scaffolds and enhanced apatite formation. Initial burst release of histone was significantly higher than that of BSA from CH scaffold, while the addition of CS or AG in the scaffolds significantly reduced the initial burst release of histone, indicating strong electrostatic interaction between histone and negatively charged CS or AG. The apatite layer created on scaffold surfaces significantly reduced the initial burst release of both BSA and histone. Furthermore, apatite-coated scaffolds enhanced spreading, proliferation, and osteogenic differentiation of BMSC seeded on the scaffolds compared to non-coated scaffolds as assessed by live/dead and alamarBlue assays, scanning electron microscopy (SEM), alkaline phosphatase (ALP) activity, and Picrosirius red staining. This study suggests that apatite-coated CH/CS composite scaffolds have the potential as a promising osteogenic system for bone tissue engineering applications.
Collapse
Affiliation(s)
- Hyejin Park
- Division of Advanced Prosthodontics, University of California, Los Angeles, CA 90095, United States
| | | | | | | | | | | | | |
Collapse
|
9
|
Duaibis R, Kusnoto B, Natarajan R, Zhao L, Evans C. Factors affecting stresses in cortical bone around miniscrew implants. Angle Orthod 2012; 82:875-80. [DOI: 10.2319/111011-696.1] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
10
|
BOCCACCIO ANTONIO, LAMBERTI LUCIANO, PAPPALETTERE CARMINE. EFFECTS OF AGING ON THE LATENCY PERIOD IN MANDIBULAR DISTRACTION OSTEOGENESIS: A COMPUTATIONAL MECHANOBIOLOGICAL ANALYSIS. J MECH MED BIOL 2011. [DOI: 10.1142/s0219519408002644] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Mandibular symphyseal distraction osteogenesis is a clinical procedure utilized in orthodontics for solving problems of dental overcrowding on the mandibular arch. A critical issue is to evaluate the optimal duration of the latency period between the osteotomy and the first aperture of distraction device. In fact, the latency period should change with the patient's age. To this end, a computational mechanobiological model has been developed in order to find optimal durations of latency period for young, adult, and elder patients. The model is implemented in a finite element framework simulating the process of tissue differentiation in the bone callus formed after osteotomy. The biophysical stimulus regulating the tissue differentiation process is hypothesized to be a function of the octahedral shear strain and interstitial fluid flow velocity. The resulting spatial distribution of stiffness properties in the callus region is analyzed in order to assess the risk of premature bone union of osteotomy edges. The three-dimensional (3D) finite element model (FEM) of human mandible is reconstructed from computed tomography (CT) scans and also includes a tooth-borne device. Under unilateral occlusion, the mandible is submitted to full mastication loading or to mastication forces reduced by 70%. The results show that optimal durations of the latency period for preventing premature bone union are about 5–6 days for the young patient, 7–8 days for the adult patient, and 9–10 days for the elder patient. These durations seem rather insensitive to the magnitude of mastication forces. Finally, distraction force values predicted by the present mechanobiological model are in good agreement with data reported in the literature.
Collapse
Affiliation(s)
- ANTONIO BOCCACCIO
- Department of Mechanical and Management Engineering, Polytechnic of Bari, Bari 70126, Italy
| | - LUCIANO LAMBERTI
- Department of Mechanical and Management Engineering, Polytechnic of Bari, Bari 70126, Italy
| | - CARMINE PAPPALETTERE
- Department of Mechanical and Management Engineering, Polytechnic of Bari, Bari 70126, Italy
| |
Collapse
|
11
|
BOCCACCIO ANTONIO, LAMBERTI LUCIANO, PAPPALETTERE CARMINE, QUAGLIARELLA LIVIO. EVALUATION AND MINIMIZATION OF GEOMETRIC RECONSTRUCTION ERRORS IN FEM MODELS GENERATED FROM CT-SCAN IMAGES. J MECH MED BIOL 2011. [DOI: 10.1142/s0219519409002973] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
CAD reconstruction of anatomical regions from computerized tomography (CT) scans is a very common approach in orthopaedic biomechanics. The CAD model is discretized into finite volume sub-domains and finite element (FE) analyses are performed in order to predict the distribution of stresses generated by applied loads. However, quality and reliability of numerical results depend on the level of accuracy reached in the meshing process. This paper analyzes some critical parameters that may affect the overall efficiency of the CT–FEM transformation process: scan threshold range, object size, and complexity. An optimization procedure for minimizing geometric errors on size and shape of reconstructed objects is presented. Finally, accuracy of stress predictions is evaluated for FE models that include known amounts of geometric errors. Compression and bending loads are considered. Results show that geometric and stress errors rapidly decrease as the objects to be reconstructed become larger in size. Optimal threshold ranges can be identified clearly for both an epoxy-resin benchmark model and a real bone specimen cut from a human lumbar vertebra. This allows geometric errors to be reduced significantly.
Collapse
Affiliation(s)
- ANTONIO BOCCACCIO
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Bari, Italy
| | - LUCIANO LAMBERTI
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Bari, Italy
| | - CARMINE PAPPALETTERE
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Bari, Italy
| | - LIVIO QUAGLIARELLA
- Centro Interuniversitario Servizi di Ingegneria Biomedica, Università degli Studi di Bari, Bari, Italy
| |
Collapse
|
12
|
Boccaccio A, Ballini A, Pappalettere C, Tullo D, Cantore S, Desiate A. Finite element method (FEM), mechanobiology and biomimetic scaffolds in bone tissue engineering. Int J Biol Sci 2011; 7:112-32. [PMID: 21278921 PMCID: PMC3030147 DOI: 10.7150/ijbs.7.112] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2010] [Accepted: 10/16/2010] [Indexed: 01/07/2023] Open
Abstract
Techniques of bone reconstructive surgery are largely based on conventional, non-cell-based therapies that rely on the use of durable materials from outside the patient's body. In contrast to conventional materials, bone tissue engineering is an interdisciplinary field that applies the principles of engineering and life sciences towards the development of biological substitutes that restore, maintain, or improve bone tissue function. Bone tissue engineering has led to great expectations for clinical surgery or various diseases that cannot be solved with traditional devices. For example, critical-sized defects in bone, whether induced by primary tumor resection, trauma, or selective surgery have in many cases presented insurmountable challenges to the current gold standard treatment for bone repair. The primary purpose of bone tissue engineering is to apply engineering principles to incite and promote the natural healing process of bone which does not occur in critical-sized defects. The total market for bone tissue regeneration and repair was valued at $1.1 billion in 2007 and is projected to increase to nearly $1.6 billion by 2014.Usually, temporary biomimetic scaffolds are utilized for accommodating cell growth and bone tissue genesis. The scaffold has to promote biological processes such as the production of extra-cellular matrix and vascularisation, furthermore the scaffold has to withstand the mechanical loads acting on it and to transfer them to the natural tissues located in the vicinity. The design of a scaffold for the guided regeneration of a bony tissue requires a multidisciplinary approach. Finite element method and mechanobiology can be used in an integrated approach to find the optimal parameters governing bone scaffold performance.In this paper, a review of the studies that through a combined use of finite element method and mechano-regulation algorithms described the possible patterns of tissue differentiation in biomimetic scaffolds for bone tissue engineering is given. Firstly, the generalities of the finite element method of structural analysis are outlined; second, the issues related to the generation of a finite element model of a given anatomical site or of a bone scaffold are discussed; thirdly, the principles on which mechanobiology is based, the principal theories as well as the main applications of mechano-regulation models in bone tissue engineering are described; finally, the limitations of the mechanobiological models and the future perspectives are indicated.
Collapse
Affiliation(s)
- A Boccaccio
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, 70126 Bari, Italy.
| | | | | | | | | | | |
Collapse
|
13
|
Salles C, Chagnon MC, Feron G, Guichard E, Laboure H, Morzel M, Semon E, Tarrega A, Yven C. In-Mouth Mechanisms Leading to Flavor Release and Perception. Crit Rev Food Sci Nutr 2011; 51:67-90. [DOI: 10.1080/10408390903044693] [Citation(s) in RCA: 118] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
14
|
Ammar HH, Ngan P, Crout RJ, Mucino VH, Mukdadi OM. Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement. Am J Orthod Dentofacial Orthop 2011; 139:e59-71. [DOI: 10.1016/j.ajodo.2010.09.020] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2010] [Revised: 09/01/2010] [Accepted: 09/01/2010] [Indexed: 11/30/2022]
|
15
|
Reina-Romo E, Sampietro-Fuentes A, Gómez-Benito M, Domínguez J, Doblaré M, García-Aznar J. Biomechanical response of a mandible in a patient affected with hemifacial microsomia before and after distraction osteogenesis. Med Eng Phys 2010; 32:860-6. [DOI: 10.1016/j.medengphy.2010.05.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2009] [Revised: 05/25/2010] [Accepted: 05/29/2010] [Indexed: 10/19/2022]
|
16
|
Three-Dimensional Simulation of Mandibular Distraction Osteogenesis: Mechanobiological Analysis. Ann Biomed Eng 2010; 39:35-43. [DOI: 10.1007/s10439-010-0166-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2010] [Accepted: 09/10/2010] [Indexed: 11/26/2022]
|
17
|
Boccaccio A, Cozzani M, Pappalettere C. Analysis of the performance of different orthodontic devices for mandibular symphyseal distraction osteogenesis. Eur J Orthod 2010; 33:113-20. [PMID: 20709724 DOI: 10.1093/ejo/cjq050] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The aim of this study was to investigate the performance of different orthodontic devices for mandibular symphyseal distraction osteogenesis (MSDO). Two performance parameters were analysed, the first of which concerned the stability guaranteed by a distractor in the fracture gap under mastication loads and the second the level of reliability with which a distractor transfers a given expansion to the mandibular bone, inasmuch as the more reliable the device the smaller the difference between the degree of expansion provided to the device and the displacement achieved on the mandibular arch. Hence, a non-linear finite element (FE) model of a human mandible with different devices (tooth-borne, bone-borne, and hybrid) was constructed and then utilized to assess the structural behaviour of the mandibular bone under distraction and mastication loads. An ad hoc algorithm was developed to simulate progressive expansion of the devices; a distraction protocol comprising a 10 day latency period and a 6 day distraction period was hypothesized. The first hypothetical expansion given to the device was 2 mm, and the five subsequent expansions were 1 mm. The results showed that the hybrid device was the most stable appliance under mastication loads, followed by the tooth- and bone-borne devices. However, parasitic rotations of the mandibular arms caused by mastication might counteract the benefits of distraction. The tooth-borne device was found to have the highest reliability in transferring expansion to the mandibular bone. For this device, mandibular expansion was less than the nominal aperture of the distractor by no more than 15 per cent. Lower values of reliability were achieved with the bone-borne device. As the values of the aperture of the appliances increased, the stability guaranteed in the fracture gap increased while the reliability in transferring expansion to the mandibular arch decreased.
Collapse
Affiliation(s)
- A Boccaccio
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Viale Japigia 182, 70126 Bari, Italy.
| | | | | |
Collapse
|
18
|
Gracco A, Cirignaco A, Cozzani M, Boccaccio A, Pappalettere C, Vitale G. Numerical/experimental analysis of the stress field around miniscrews for orthodontic anchorage. Eur J Orthod 2008; 31:12-20. [DOI: 10.1093/ejo/cjn066] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
19
|
Modeling distraction osteogenesis: analysis of the distraction rate. Biomech Model Mechanobiol 2008; 8:323-35. [DOI: 10.1007/s10237-008-0138-x] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2007] [Accepted: 08/04/2008] [Indexed: 10/21/2022]
|
20
|
Comparison of different orthodontic devices for mandibular symphyseal distraction osteogenesis: A finite element study. Am J Orthod Dentofacial Orthop 2008; 134:260-9. [DOI: 10.1016/j.ajodo.2006.09.066] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2006] [Revised: 09/01/2006] [Accepted: 09/01/2006] [Indexed: 11/21/2022]
|
21
|
Micromechanics-Based Conversion of CT Data into Anisotropic Elasticity Tensors, Applied to FE Simulations of a Mandible. Ann Biomed Eng 2007; 36:108-22. [DOI: 10.1007/s10439-007-9393-8] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2007] [Accepted: 10/10/2007] [Indexed: 10/22/2022]
|
22
|
Boccaccio A, Prendergast PJ, Pappalettere C, Kelly DJ. Tissue differentiation and bone regeneration in an osteotomized mandible: a computational analysis of the latency period. Med Biol Eng Comput 2007; 46:283-98. [PMID: 17899238 DOI: 10.1007/s11517-007-0247-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2007] [Accepted: 08/18/2007] [Indexed: 10/22/2022]
Abstract
Mandibular symphyseal distraction osteogenesis is a common clinical procedure to modify the geometrical shape of the mandible for correcting problems of dental overcrowding and arch shrinkage. In spite of consolidated clinical use, questions remain concerning the optimal latency period and the influence of mastication loading on osteogenesis within the callus prior to the first distraction of the mandible. This work utilized a mechano-regulation model to assess bone regeneration within the callus of an osteotomized mandible. A 3D model of the mandible was reconstructed from CT scan data and meshed using poroelastic finite elements (FE). The stimulus regulating tissue differentiation within the callus was hypothesized to be a function of the strain and fluid flow computed by the FE model. This model was then used to analyse tissue differentiation during a 15-day latency period, defined as the time between the day of the osteotomy and the day when the first distraction is given to the device. The following predictions are made: (1) the mastication forces generated during the latency period support osteogenesis in certain regions of the callus, and that during the latency period the percentage of progenitor cells differentiating into osteoblasts increases; (2) reducing the mastication load by 70% during the latency period increases the number of progenitor cells differentiating into osteoblasts; (3) the stiffness of new tissue increases at a slower rate on the side of bone callus next to the occlusion of the mandibular ramus which could cause asymmetries in the bone tissue formation with respect to the middle sagittal plane. Although the model predicts that the mastication loading generates such asymmetries, their effects on the spatial distribution of callus mechanical properties are insignificant for typical latency periods used clinically. It is also predicted that a latency period of longer than a week will increase the risk of premature bone union across the callus.
Collapse
Affiliation(s)
- A Boccaccio
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Bari, Italy
| | | | | | | |
Collapse
|
23
|
Boccaccio A, Pappalettere C, Kelly DJ. The Influence of Expansion Rates on Mandibular Distraction Osteogenesis: A Computational Analysis. Ann Biomed Eng 2007; 35:1940-60. [PMID: 17768683 DOI: 10.1007/s10439-007-9367-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2006] [Accepted: 08/06/2007] [Indexed: 10/22/2022]
Abstract
Mandibular distraction osteogenesis is a clinical procedure used for modifying the mandibular geometry when problems of dental overcrowding and arch shrinkage occur. The objective of this study is to use a computational model of tissue differentiation to examine the influence of the rate of distraction on bone re-growth within the fracture callus of a human mandible submitted to symphyseal distraction osteogenesis. A 3D model of the mandible is reconstructed from CT scan data and meshed into finite elements. Two different mastication loadings have been investigated: a 'full' mastication load and a 'reduced' mastication load where the action of each muscle was reduced by 70%. Four different distraction rates were analyzed: 0.6, 1.2, 2, and 3 mm/day, allowing a total displacement of 6 mm. In the early stages of the distraction process it is predicted that there is a decrease in the amount of bone tissue forming within the center of the fracture gap for all distraction rates. After the initial phases of expansion, the bone tissue within the callus increases for the slower rate of distraction or continues to decrease at the faster rates of distraction. At the end of the simulated maturation period, 47% of the distracted callus was predicted to consist of bone tissue for a distraction rate of 0.6 mm/day, decreasing to 22% for a distraction rate of 3 mm/day. Significantly higher amounts of bone formation were predicted for all distraction rates for the case of reduced mastication loading. Disparities between the model predictions and what is observed in vivo were found. For instance, during the latency period, the distraction period and beyond, the model is predicting larger than expected amounts of cartilage tissue formation within the callus. This and other limitations of the proposed model are discussed and possible specific explanations for these disparities are provided in the paper. The model predicts a distraction rate of around 1.2 mm/day to be optimal as higher rates produce less bone tissue while the risk of a premature bone union is greater at slower rates of distraction because in the latter stages of the distraction process bone tissue is predicted to form between the left and right side of the bone callus.
Collapse
Affiliation(s)
- A Boccaccio
- Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Bari 70126, Italy
| | | | | |
Collapse
|